Académique Documents
Professionnel Documents
Culture Documents
A
X
6
7
REVISIONS
C
D
0
1
SHEET
REVISIONS
C
D
0
1
41
42
X
43
44
45
46
47
48
49
10
50
11
51
12
52
13
53
14
54
15
55
16
56
17
57
18
58
19
59
20
60
21
61
22
62
23
63
24
64
25
65
26
66
27
67
28
68
29
69
30
70
31
71
32
72
33
73
34
74
35
75
36
76
37
77
38
78
39
79
40
80
D-100-MDA-WHP-DSM-502 Rev. D
Page 2 of 7
Page
No
Date
COMPANY Comment
Implemented
(Y/N)
Explanation/Remarks
All
12/2/2016
IDC Comment
Incorporated
30/3/2016
30/3/2016
30/3/2016
30/3/2016
30/3/2016
30/3/2016
30/3/2016
30/3/2016
Incorporated
Incorporated
Incorporated
No personnel protection
Incorporated
Accessories.
Pls add Internal part:
1. Demister
2. Vortex breaker (if required)
Material Spec. - Support.
Revise Support to skirt
Note 2.
Revise manhole with top cover
Note 16.
1. How to installed demister?
2. What is the maximum weight if it will
Incorporated
Incorporated
Incorporated
10
30/3/2016
11
30/3/2016
12
30/3/2016
13
30/3/2016
14
30/3/2016
Note 15.
Please check process data for liquid
droplet and gas side
30/3/2016
Note.
Add note:
17. Material cert. shall be in accordance
with BS EN 10204 type 3.1 for all pressure
parts and type 2.2 for all non-pressure
parts.
18. Lifting lugs shall be designed with
factor 2.0
19. SS316L shall be used for name plate
20. Demister material spec.
Incorporated
15
D-100-MDA-WHP-DSM-502 Rev. D
Page 3 of 7
Page
No
16
17
18
19
20
21
22
23
Date
COMPANY Comment
Sketch.
30/3/2016 Please check vertical space/head room for
demister replacement
Sketch - Top cover.
30/3/2016
any screw jacking bolt
Sketch.
30/3/2016
Add in nozzle list for top manway
Sketch - Skirt opening
30/3/2016 Pls consider maintenance access
(circular/oval)?
Sketch - N5.
30/3/2016
Any break flange/Support?
Sketch - Shell MW
Please consider opening size and compare
30/3/2016
with ID. Why don't provide handhole for
maintenance purpose.
Sketch - Level Setting.
30/3/2016
Pls check as per latest PID for level
Nozzle - N1.
30/3/2016
Add "(demister)
Sketch
Is this vessel sizing and demister details
30/3/2016
preliminary and VENDOR to check and
finalize?Please mention very clearly
Nozzle List - MW.
The inside vessel diameter is too tight
(1200mm) and the height is also too
30/3/2016 short (less than 2400mm include
demister) for any confined space work.
There is only one way access from the
top of scrubber to replace the internal
Implemented
(Y/N)
Explanation/Remarks
Incorporated
Incorporated
Incorporated (Circular)
Incorporated
Incorporated
24
25
26
30/3/2016
Accessories - Fireproofing
Release HOLD - No Fireproofing as per
FERA by SAFETY.
27
30/3/2016
Note 12 - deleted
Duplication with note 16.
28
30/3/2016
Note 14 - deleted
Seismic & shipmotion data already
specified.
29
All
6/6/2016
30
6-7
6/6/2016
31
6/6/2016
D-100-MDA-WHP-DSM-502 Rev. D
Approved
Incorporated
Sketch - Elevation & Top View
Revise nozzle orientation & elevation
Accessories.
Tick for anchor bolt
Page 4 of 7
REVISION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
Client
Project
Location
Contract No.
Construction Code
Pressure Vessel Specification
Design Pressure
Min. / Max.
Design Temperature
Min. Design Metal Temperature (MDMT)
Operating Pressure
Operating Temperature
Radiography
Corrosion Allowance
Gas
Density
Liquid
Max. Liquid Level
Wind Design Code
Design Wind Speed
Exposure
Importance Factor
Seismic Design Code
SLE 500 Years, Seismic Zone
DLE 2500 Years, Soil Profile
Blast Pressure
Horiz. Accelerations
Ship Motion
Vert. Accelerations
ID
Size
T/F
Length
Shell Thickness
Top
Head Thickness
Bottom
Demister Type
Demister Thickness
Title
Tag Number
No. Required
Doc. No.
DESIGN DATA
ASME VIII Div 1, 2015 Edition
Corrosive Service
Yes
D-100-MDA-WHP-SPM-516
Cyclic Service
Yes
200
psig Other Special Service
-150
F
Code Stamp
Yes
-20
F
MIGAS Certificate
(Note 11)
Yes
140
psig MAWP Basis
Calculated
42.5
F
Impact Test
Yes
Spot PWHT
Full
Yes, Per Serv.
0.125
in
1.3 x MAP
Hydrotest
0.547
lb / ft
63.8
lb / ft
Yes,
thk:
in.
Insulation (By Others)
22
in.
No
API RP2A
Yes,
thk:
in.
Fireproofing (By Others)
63.62
mph
No
ACCESSORIES
Platform / Ladder Clips
Internal Ladder
0.25
g
Insulation Clips
Top davit
0.32
g
Fireproofing Clips
Cathodic Potection
psi
Pipe Support Clips
Name Plate
20 degree
g
Earthing Lugs / Boss
Anchor Bolt
0.2
g
Lifting Lugs
Demister (Note 18)
4' - 0"
ft - in
Tailing Lugs
Vortex Breaker
8' 9"
ft - in
(*)
in
(*)
in
(*)
in
(Note 14)
(Note 14)
in
MATERIAL SPECIFICATIONS
A516 Gr. 70
Gaskets
N/A
thk: N/A in.
Pipe
Plate
A516 Gr. 70
A106 Gr.B
A516 Gr. 70
A105
A234 WPB-Seamless
A283 Gr.C
A516 Gr. 70
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
11)
12)
13)
14)
15)
16)
17)
18)
19)
20)
*
*
*
Internal
External
Internal
Boltings
External
Internals
Painting Internal Surface
Painting External Surface
Painting Specification
: Gas Scrubber
: MDA-D-1511
: One (1) Set
: D-100-MDA-WHP-DSM-502
lbs
lbs
lbs
No
No
No
No
Dsg. Press.
Per Code
Per Code
SG:
SG:
PTFE (*)
Spiral Wound SS316, Flexible Graphite,
SS316 inner & outer ring
SS316L
A193 Gr.B7 / A194 Gr.2H (phenolic epoxy
coated)
SS316L
No
Yes, Sys. No.:
No
Yes, Sys. No.:
3
D-100-MDA-WHP-SPM-012
NOTES
For process data refer to P&ID: D-100-MDA-WHP-11110, MDA Wellhead Platform Gas Scrubber and Gas Generator.
All removable internal (demister & inlet device) shall be designed to pass through top cover.
* : Indicate VENDOR to Advise / Confirm.
Minimum nozzles projection is indicated. VENDOR to advise actual projection.
All nozzle flanges shall be as per ASME B16.5.
Vessel VENDOR shall provide internal support & the required clips / brackets / fastener etc, to install the internals.
To be calculated for overall weight of the vessel with internal installed.
VENDOR to calculate / provide over all size of the equipment and specify thickness, nozzle reinforcement, stiffener details, lifting lugs, etc.
Two earthing lugs to be provided diagonally at skirt.
Design life of the equipment shall be 15 years.
VENDOR is responsible to provide all required documents to obtain MIGAS certification.
Painting shall be as per D-100-MDA-WHP-SPM-012, Specification for Piping Painting and Coating.
VENDOR to guarantee demister performance to retain liquid droplet size of 150 and large.
Demister type, thickness and dimension shall be finalized by VENDOR.
Material Certification shall be accordance with BS EN 10204 type 3.1 for all pressure parts and type 2.2 for all non-pressure parts.
Lifting lugs shall be designed with safety factor 2.0, suitable for single point lifting by crane.
SS316 nameplate complete with braket shall be provided.
Demister material specification is SS316L. Segmental design is preferred to reduce lifting weight for simple handling.
Jack bolt to be provided to facilitate top cover opening
Support for N5 extended nozzle to be finalized by VENDOR, based on nozzle load calculation.
D-100-MDA-WHP-DSM-502 Rev. D
Page 5 of 7
80
??
deleted
D-100-MDA-WHP-DSM-502 Rev. D
Page 5 of 7
REVISION
Client
Project
Location
Contract No.
: Gas Scrubber
: MDA-D-1511
: One (1) Set
: D-100-MDA-WHP-DSM-502
PN
1' - 3 3/4"
MW
N2
8'-9" T/F
6' - 7 7/16"(*)
5' - 1"
3' - 11 1/4"
K3A
HH
N4
2'- 1 9/16"
TL
REF. 0
K4B
3' - 7/16"
1' - 5 5/16"
1' - 5 5/16"
VORTEX BREAKER
K1
2'-2"
K4A
5' - 9"
K5
4' - 0" ID
2' - 7 1/2"
N1
4' - 7 5/8"
5' - 9
N6
5 7/8"(*)
7' - 11 1/16"
N3
1'- 7 11/16"(*)
DAVIT
1'-5 5/16"
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
N5
LEVEL SETTING
HHLL
1' - 10 "
HLL
1' - 6"
LLL
0' - 10"
LLLL
0' - 6"
K3B
2-EARTHING LUGS
/ BOSSES
ELEVATION VIEW
8"
NOZZLE
N1
N2
N3
N4
N5
N6
K1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
150#
150#
150#
150#
150#
150#
300#
Flange
Type
WN RF
WN RF
WN RF
WN RF
WN RF
WN RF
WN RF
K3 A/B
K4 A/B
K5
HH
MW
2
2
1
1
1
3
2
2
12
48
300#
300#
300#
150#
150#
WN RF
WN RF
WN RF
WN RF
WN RF
Mark
D-100-MDA-WHP-DSM-502 Rev. D
Rating
Proj. (in.)
(Note 4)
6
6
6
6
6
6
6
6
6
6
8
Description
Gas Inlet
Spare
Gas Outlet
Liquid Outlet
Closed Drain
Vent
PSIT153A
LG/LT151
LSIT152
PIT151
Handhole
Manway
Remark
With inlet device
Page 6 of 7
REVISION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
Client
Project
Location
Contract No.
: Gas Scrubber
: MDA-D-1511
: One (1) Set
: D-100-MDA-WHP-DSM-502
PN
N1
N6
K3A
TOPCOVER OPENING
N4
K4A
K3B
K4B
30
315
N2
N3
D-100-MDA-WHP-DSM-502 Rev. D
K1
N5
270
135
180
HH
K5
HANDHOLE OPENING
TOP VIEW
Page 7 of 7