Aspen Utilities

User Guide

Version V7.3
March 2011
Copyright (c) 1981 2011 by Aspen Technology, Inc. All rights reserved.
Aspen Utilities, Aspen Online, Aspen InfoPlus.21, Aspen Utilities Planner TM, Aspen Utilities On-Line OptimizerTM
(Utilities Optimizer), Aspen Utilities OperationsTM, Aspen SLMTM, Aspen Engineering Suite, the aspen leaf logo, and
Plantelligence & Enterprise Optimization Solutions are trademarks or registered trademarks of Aspen Technology,
Inc., Burlington, MA.
All other brand and product names are trademarks or registered trademarks of their respective companies.
This document is intended as a guide to using AspenTech's software. This documentation contains AspenTech
proprietary and confidential information and may not be disclosed, used, or copied without the prior consent of
AspenTech or as set forth in the applicable license agreement. Users are solely responsible for the proper use of
the software and the application of the results obtained.
Although AspenTech has tested the software and reviewed the documentation, the sole warranty for the software
may be found in the applicable license agreement between AspenTech and the user. ASPENTECH MAKES NO
WARRANTY OR REPRESENTATION, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THIS DOCUMENTATION,
ITS QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE.
Aspen Technology, Inc.
200 Wheeler Road
Burlington, MA 01803-5501
USA
Phone: + (781) 221-6400
Toll Free: +(1) (888) 996-7001
URL: http://www.aspentech.com

Contents
Introducing Aspen Utilities .....................................................................................1
What You Need To Use This Guide ......................................................................1
Section Descriptions ...............................................................................2
About This Document .......................................................................................2
Related Documentation .....................................................................................2
Technical Support ............................................................................................3
1 Aspen Utilities Planner User Interface .................................................................5
Starting Aspen Utilities Planner ..........................................................................5
Aspen Utilities Planner Main Window...................................................................5
Flowsheet Window..................................................................................6
Explorer Window ....................................................................................6
Message Window....................................................................................6
Optimization Menu .................................................................................6
Initializing Physical Properties ............................................................................6
Creating and Simulating an Aspen Utilities Model .................................................8
Aspen Utilities Model Library ....................................................................8
Adding Data to the Blocks .......................................................................8
Running in Simulation Mode ....................................................................8
2 Data Editors .......................................................................................................11
Profiles Editor ................................................................................................ 12
Accessing the Profiles Data Editor........................................................... 14
Editing Demand Profile.......................................................................... 15
Editing Availability Profile ...................................................................... 17
Updating Profiles .................................................................................. 18
Filtering Profile Data ............................................................................. 21
Viewing Profiles.................................................................................... 22
Printing Profiles.................................................................................... 24
Saving and Transferring Profile Data....................................................... 25
Selecting a Case .................................................................................. 26
Editing a Case...................................................................................... 27
Copying a Case .................................................................................... 28
Exporting a Case .................................................................................. 29
Changing the Location of the Databases.................................................. 31
Tariff Editor ................................................................................................... 32
Accessing the Tariff Editor ..................................................................... 33
Adding Contract ................................................................................... 35
Editing a Contract ................................................................................ 36
Deleting a Contract .............................................................................. 37
Adding Tiers ........................................................................................ 38
Editing a Tier ....................................................................................... 39
Entering Tariff Cost Equations................................................................ 39

Contents

iii

Deleting a Tier ..................................................................................... 46


Saving and Transferring Tariff Data ........................................................ 47
Printing Contracts and Tiers................................................................... 48
Demand Forecasting Editor.............................................................................. 48
Accessing the Demand Forecasting Editor................................................ 49
Calculating Utility Demands ................................................................... 50
Saving Utility Demands ......................................................................... 51
Modifying Demand Equations ................................................................. 51
Using the DFE Equation Editor ............................................................... 52
Tips for Creating Equations.................................................................... 62
Adding an Equation .............................................................................. 64
Deleting an Equation ............................................................................ 65
Displaying Equation Variables ................................................................ 66
Using the Variable Filter ........................................................................ 67
Modifying Independent Variables in Equations.......................................... 68
Calculating Utility Demands for Multiple Periods ....................................... 69
3 Optimization Configuration ................................................................................71
Enforcing Hot Standby Requirements ................................................................ 71
Configuring Startup/Shutdown Constraints ........................................................ 73
Configuring Load Shedding .............................................................................. 75
Obtaining Marginal Utility Cost ......................................................................... 77
Identifying Optimization Errors ........................................................................ 80
Presolve Error Checking ........................................................................ 81
Error Tracking...................................................................................... 82
Setting up Options for Optimization .................................................................. 85
Multiple Period Run Mode ...................................................................... 85
Settings for Mixed Integer Linear Solver............................................................ 86
Cut Strategy ........................................................................................ 86
Cut off Value (Max. Expected Cost) ........................................................ 87
Optimum Gap from Optimality (%)......................................................... 87
Presolve Strategy ................................................................................. 87
4 Aspen Utilities On-line Implementation..............................................................89
Calculating Utility Demand Targets ................................................................... 89
Specifying Demands for On-line Optimization .................................................... 91
5 Microsoft Excel Interface....................................................................................93
Installing the Aspen Utilities Planner Add-In ...................................................... 93
Aspen Utilities Excel Menu Items ............................................................ 94
Open Aspen Utilities File........................................................................ 95
Running a Simulation from Excel ...................................................................... 95
Creating a Simulation Links worksheet.................................................... 96
Configuring Blocks and Variables for Input to Aspen Utilities Planner .......... 97
Configuring Blocks and Variables for Retrieval from Aspen Utilities Planner .. 98
Mapping Variable Values to the Excel Flowsheet ..................................... 100
Running Data Reconciliation from Excel........................................................... 101
Accessing Reconciliation Worksheet ...................................................... 102
Configuring Blocks and Variables for Reconciliation................................. 103
Running Optimization from Excel.................................................................... 104
Performing User Specific Tasks before Optimization ................................ 105

iv

Contents

Producing Optimization Results and Tariff Information from Aspen Utilities 106
Obtaining Results from Multi-Period Optimization ................................... 109
6 Aspen Utilities Planner Reference ....................................................................111
Model Library............................................................................................... 111
List of Models .................................................................................... 112
General Model Structure ..................................................................... 113
Standard Variable Names in Models ...................................................... 114
Ports and Streams.............................................................................. 115
Specifying Capacity Limits ................................................................... 115
Feeds ............................................................................................... 116
Demands .......................................................................................... 120
Headers ............................................................................................ 124
Steam Models .................................................................................... 127
Pumps .............................................................................................. 132
Turbines............................................................................................ 137
Heat Exchangers ................................................................................ 142
Multipliers ......................................................................................... 151
Fuel Models ....................................................................................... 154
Emissions.......................................................................................... 169
Templates ......................................................................................... 177
Flowsheet Development ................................................................................ 179
Dealing with Snapshots....................................................................... 179
Variable Specification Fixed and Free ................................................. 179
Appendix 1 Configuring the Demand Forecasting Editor...................................181
Before you Start .......................................................................................... 183
Units of Measure .......................................................................................... 185
Configuring General Information .................................................................... 185
EquationTypes ................................................................................... 185
Operators.......................................................................................... 186
Config............................................................................................... 186
PeriodSet .......................................................................................... 186
Period ............................................................................................... 186
GeneralInput ..................................................................................... 187
Configuring Production Parameters ................................................................. 187
DemandForecasting Input ................................................................... 187
XinVal............................................................................................... 189
Configuring Modes........................................................................................ 190
TblModes .......................................................................................... 190
TblModeValues................................................................................... 191
PeriodModes ...................................................................................... 191
Configuring Calculations................................................................................ 192
tblEquationDefinition .......................................................................... 192
CalcVars ........................................................................................... 193
Configuring Demand Calculations ................................................................... 195
DemandCalcsEquations ....................................................................... 195
DemandCalcs..................................................................................... 195
Index ..................................................................................................................197

Contents

Introducing Aspen Utilities

In this document Aspen Utilities is used as a generic term to refer to both


Aspen Utilities On-Line Optimizer (Utilities Optimizer), formerly known as
Aspen Utilities Operations, and Aspen Utilities Planner.
Aspen Utilities V7.3 is an equation-oriented tool for the simulation and
optimization of Utility Systems (Fuel, Steam and Power), specially designed to
address all the business processes related to the operation and management
of utility systems.
It can be used to address all the key issues in the purchase, supply and usage
of fuel, steam and power within environmental constraints, and provides a
single tool to optimize energy business processes and substantially improve
financial performance.
Aspen Utilities is based on Aspen Custom Modeler. The software is supplied
with a library of unit operations associated with utility systems. You can also
write your own unit operation models and add these to the library.
Aspen Utilities uses a Mixed Integer Linear Programming (MILP) solver for
optimization.

What You Need To Use This


Guide
To use this guide, you need Aspen Utilities Planner installed on PC or PC file
server running Windows 2000 or Windows XP. For information on how to do
this, read the Installation Guide supplied with the product, or contact your
system administrator.

Introducing Aspen Utilities

Section Descriptions
This guide contains the following sections:
Introduction a brief overview of the guide and a list of related
documentation.
Section 1 Aspen Utilities Planner User Interface an overview of the
application software and how to create an Aspen Utilities model.
Section 2 Data Editors Detailed information on inputting data into Aspen
Utilities utility demands, equipment availability, tariff information, and
utility demand forecasting.
Section 3 Optimization Configuration how to achieve certain optimization
objectives such as hot standby requirements, startup/shutdown constraints,
load shedding, and others. Also how to diagnose optimization problems.
Section 4 Aspen Utilities On-line Implementation an overview of using
Aspen Utilities Planner with Aspen Online to get data from the plant data
historian and run calculations.
Section 5 Microsoft Excel Interface how to run Aspen Utilities and view
results from Microsoft Excel and the necessary prerequisites.
Section 6 Aspen Utilities Reference detailed information covering the models
used in Aspen Utilities and some ideas on flowsheet development.
Appendix 1 Configuring the Demand Forecasting Editor detailed information
about the demand forecasting application; a subset of tables within the
demand database. These need to be configured following a certain
convention.
Glossary an explanation of terms used throughout this guide.

About This Document


This guide is suitable for Aspen Utilities Planner V7.3 users of all levels of
experience, from new user to power-user.
For details of basic workflow, refer to the associated Getting Started guide or
the Getting Started topics in the on-line help.

Related Documentation
In addition to this document and the on-line Help system supplied with Aspen
Utilities, the following documents are provided in PDF format to help users
install, learn and use Aspen Utilities.

Title

Content

Aspen Engineering Whats New and Aspen

Information about new features and

Introducing Aspen Utilities

Engineering Known Issues

known issues and workarounds.

Aspen Engineering Installation Guide and


SLM Installation and Reference Guide

Full installation requirements and


procedures required to install, verify
license and run Aspen Utilities.

Aspen Utilities Getting Started Guide

Tutorials designed to train first-time


users in the main functionality and
features of Aspen Utilities.

Technical Support
AspenTech customers with a valid license and software maintenance
agreement can register to access the online AspenTech Support Center at:
http://support.aspentech.com
This Web support site allows you to:

Access current product documentation

Search for tech tips, solutions and frequently asked questions (FAQs)

Search for and download application examples

Search for and download service packs and product updates

Submit and track technical issues

Send suggestions

Report product defects

Review lists of known deficiencies and defects

Registered users can also subscribe to our Technical Support e-Bulletins.


These e-Bulletins are used to alert users to important technical support
information such as:

Technical advisories

Product updates and releases

Customer support is also available by phone, fax, and email. The most up-todate contact information is available at the AspenTech Support Center at
http://support.aspentech.com.

Introducing Aspen Utilities

Introducing Aspen Utilities

1 Aspen Utilities Planner


User Interface

Starting Aspen Utilities Planner


To start Aspen Utilities Planner:
1

Click Start, and then select All Programs.

Point to AspenTech | Process Modeling V7.3, | Aspen Utilities


Planner, and then click Aspen Utilities Planner to launch the
application with a new flowsheet file already loaded.

To open an existing simulation, click File | Open.

In the Open dialog box, use the Look in list box to locate the directory
where the file is stored, select the file you want to open, and click Open.

Aspen Utilities Planner Main


Window
When you start Aspen Utilities Planner, the main window appears:

1 Aspen Utilities Planner User Interface

Optimization Menu

All Items Pane


Flowsheet Window

Contents Pane

Message Window

Flowsheet Window
The flowsheet window is where you build the flowsheet.

Explorer Window
The Explorer Window contains the All Items pane and the Contents pane.

Message Window
The message window displays all messages from Simulation to Optimization.

Optimization Menu
These menu items are used to edit/set the input for optimization to launch
the Profiles and Tariff Editors, to make optimization settings, and to start an
optimization run.

Initializing Physical Properties


When starting a new Aspen Utilities model you must initialize the physical
properties:

1 Aspen Utilities Planner User Interface

Click on Component Lists in the Explorer pane.

Double-click on Default in the Contents pane. Please Confirm This


Operation dialog box is generated. Click Yes.

Physical Properties Configuration dialog box appears, allowing you to


set the physical properties.

Use Aspen property system allows you to configure using


embedded Aspen properties.
Click Use Properties definition file. Click Browse and use the Look
In list box to locate the directory where the file AspenUtilities.appdf
is stored. This is stored in the Examples subdirectory of the Aspen
Utilities installation.

Note: The default location of AspenUtilities.appdf is: installation


drive\Program Files\AspenTech\Aspen Utilities Planner
V7.3\Examples.
The other two options: Import Aspen Properties file and Edit using
Aspen Properties are used to change the water physical property
methods or to add components for some custom reason.
o

Use custom properties allows you to use custom physical


properties. You can build a component set.

Dont use properties allows properties not to be used.

Click OK when you have located the file.

If you select AspenUtilites.appdf, a Build Component List form is


loaded. This has a single component, H2O in the left hand pane. Use the
arrows in the center of the form to move the component to the right hand
pane. Click OK.

1 Aspen Utilities Planner User Interface

Creating and Simulating an


Aspen Utilities Model
Aspen Utilities Model Library
All unit operation and stream models are located in the Utilities Library. This
can be accessed from the All Items pane in the Explorer window.
To select a model or stream:
1

In the tree view in the All Items pane, expand the Utilities subfolder
under the Libraries folder, you can select all utilities models and streams
from Stream Type subfolder and Utility_Models subfolder.

Drag the model or stream onto the flowsheet window.

All of the functionality of Aspen Custom Modeler is available within Aspen


Utilities Planner. You can rename blocks and streams, and resize, rotate,
and flip blocks. Click on the block and right click to allow access to all of
these functions.

Adding Data to the Blocks


Data input for the various blocks is done with forms. Double-clicking on a
block loads a Summary form which contains most of the variables you want
to access. Other forms can be accessed by choosing the block, right clicking,
then choosing Forms in the context menu.
All blocks have the following forms:

AllVariables contains all of the variables within the block.

Summary contains a selection of variables that you may want to


specify or view.

Optimization_Limits allows you to specify hard constraints for the


item of equipment, for example, minimum steam generation capacity or
maximum power generation, etc.

Blocks may have additional forms, for example to add efficiency curves to the
block.

Running in Simulation Mode


When the flowsheet is built, it can be run in Simulation Mode provided the
model is square (i.e., the number of equations defined in the model is equal
to the number of Free variables).

1 Aspen Utilities Planner User Interface

A simulation can be started by clicking Simulation Run on the tool bar or


from the Run menu.

1 Aspen Utilities Planner User Interface

10

1 Aspen Utilities Planner User Interface

2 Data Editors

There are three basic types of information input into Aspen Utilities: utility
demands, equipment availabilities, and utility tariffs. Utility demands are the
amount of each utility (e.g., HP Steam, LP Steam, etc.) that must be supplied
by the utility system. Equipment availabilities define the availability of utility
system equipment whether the equipment is available, its minimum and
maximum, etc. These demands and availabilities can be entered for one time
period or multiple time periods. In Aspen Utilities, demands and availabilities
are entered in the Profiles Editor; the utility tariffs are entered in the Tariff
Editor. Both editors are available within the same form. Apart from the above
two editors, Aspen Utilities also has a tool for calculating utility demands from
plant production rates and operating conditions, called Demand Forecasting.
Results from Demand Forecasting can be transferred to the demand profile in
the Profiles Form. The Demand Forecasting Editor, also known as DFE, is now
available within the same form as the Tariff and Profiles editors.
All data is stored in Microsoft Access databases by default, but other
databases Oracle and SQL Server are supported. Profile data is stored in
ProfileData.mdb, Tariff data is stored in TariffData.mdb, and Demand
forecasting data is stored in DemandData.mdb. Apart from these three
databases, there is a fourth database used by Aspen Utilities Interface.mdb
which is an internal database used by optimization to collect and hold data
from the other databases and store results from an optimization run. The
following diagram highlights the overall relationships between various data
editors and corresponding databases.

2 Data Editors

11

Profiles Editor
The Profiles Editor is used to enter data for utility demands and equipment
availability. Profile data is grouped in cases. Each case contains an equipment
availability profile, a utility demand profile, and a period set. A period set
contains any number of time periods, each with its own start and end time.
The Profiles Editor form is shown here for a case named Case1.

12

2 Data Editors

The Demand Profile for Case1 is displayed with all areas, all equipments, and
all periods:

The demand profile shown above relates to the example.auf flowsheet in the
Aspen Utilities Examples folder.
In general, the demand profile shows the demand for utilities external to the
utility system flowsheet, from the process units. The example above shows
steam demand from the process units as HP Steam Use. Demands are
usually linked to feed or demand blocks in the flowsheet. The availability
profile shows availability and constraints on equipment modeled in the Aspen
Utilities flowsheet. Data for demands and availabilities are entered in the form
of a range Min and Max. If the value is fixed, enter the same value for the
minimum and maximum.
Before the Profiles Editor can be used it is necessary to configure the profiles
database with data from the Aspen Utilities model that has been developed.
Refer to the Updating Profiles section later in this chapter.
In general, the steps in using the editor are:
1

Open the Profiles Editor.

Make the changes required to the demand and availability profiles. Use
Update to add or delete profiles according to the flowsheet changes.
Note: The Update button is only available when the editor is launched
from within Aspen Utilities. Its not available in the standalone Editor
launched from the Start menu.

2 Data Editors

Click Save to save the data. The running status bar shows the progress. It
displays Profile data saved successfully when the save is completed.

13

Click Commit to send the data to the optimizer. (Specifically, to the


Interface database.)

When prompted by a period dialog, select the periods that should have
data sent to the optimizer.

Click Apply.

Click

to close the editor.

Accessing the Profiles Data Editor


You can access the Profiles Editor from the Optimization menu within Aspen
Utilities by clicking on Editors then clicking Profile on the Aspen Utilities
Planner Data Editors menu bar.

14

2 Data Editors

The following editor appears:

Editing Demand Profile


Before editing demand profiles, you need to have the equipment names and
related port names set up in the profile database tables.
Please refer to the Updating Profiles section for details. In this section, we
assume all the database tables are set up and you are only interested in
editing the existing profiles.

2 Data Editors

15

When the editor starts, it displays the Demand profiles. You can change
between Demand and Availability profiles by selecting the appropriate radio
button as shown below:

You can type in the minimum and maximum values for the selected demand
profiles as well as its unit of measure. The fields for the demand profile are:

Legend this is a description of the data.

Start Time this is the starting time and date for the period to which the
data relates.

End Time this is the ending time and date for the period to which the
data relates.

You cannot alter Legend, Start Time, and End Time with the editor. The time
is setup in the demand database. However, you could change them directly in
the profile database if necessary.

16

Min the minimum value in the range.

Max the maximum value in the range.

Unit the unit of measure for data entry and display. The default unit of
measure is defined within the profiles database but for any editing session
this can be changed by double clicking on the unit and selecting a new
unit.

Area the field used to group the processes in the plant. Area is
particularly useful for a multiplant case, where process units are often
located in different geographical locations (north, south, etc.). Refer to the
Updating Profiles section for how to set areas.

2 Data Editors

Editing Availability Profile


You display and edit the equipment availability profile by selecting the View
Availability Profile radio icon. The availability profile shown below relates to
the example.auf flowsheet in the Aspen Utilities Examples directory.

The Availability profile allows you to define equipment availability (on or off)
and set equipment constraints. Usually equipment design constraints are set
within the definition of the block in Aspen Utilities. However, these constraints
can be further refined within the availability profile. For example, a boiler may
be designed to generate a maximum 200 t/h of steam and have a 25%
turndown. Therefore, within the definition of the block in Aspen Utilities the
optimization limits can be set as follows:

MinStmFlow = 50 ton/hr.

MaxStmFlow = 200 ton/hr.

However, if for some reason the maximum generation of steam from the
boiler is limited to 150 ton/hr, this can be set as the maximum value. When
optimization is invoked, the more constraining of the limits set in the
availability profile or the optimization limits are taken.
Note: The availability profile has more than one type of data for the same
piece of equipment - availability and range (Minimum and Maximum).
The availability profile has the following data:

Legend a description of the data. You cannot change this value within
the editor.

Start Time the starting time and date for the period to which the data
relates. You cannot change this value within the editor.

End Time the ending time and date for the period to which the data
relates. You cannot change this value within the editor.

Min Value the minimum value of the range. If the data item is related
to equipment availability then this box is disabled.

Max Value the maximum value of the range. If the data item is related
to equipment availability then the box has a drop down list allowing you to
select the following options:
o

2 Data Editors

Not Available the item of equipment is not available for use; for
example, it is down for maintenance. In this case the optimizer cannot
switch on the unit even if it is economic to do so.

17

Available the item of equipment is available for use. The optimizer


can switch it on or off depending upon the economics.

Must be on the item of equipment must be used even if it is not


economic to do so. If equipment must be on and it is not economic to
do so, the item of equipment is usually operated at the minimum
setting.

Unit the unit of measure for data entry and display. The default unit of
measure is defined within the profiles database but for any editing session
this can be changed by double clicking on the unit and selecting a new
unit.

Area The field used to group the processes in the plant. Area is
particularly useful for a multiplant case, where process units are often
located in different geographical locations (north, south, etc.). Refer to the
Updating Profiles section for how to set areas.

If equipment availability is set as Available, the minimum value for all settings
for that piece of equipment should be set to 0 within the availability profile.
This allows the equipment usage to go to zero (not used) during the
optimization.

Updating Profiles
Before using the Editor to edit the demand and availability profiles, the
underlying Profiles database must be set up properly. The database must
contain the equipment and port name associated with the profile, its display
unit of measure, etc. As the flowsheet is developed, new process blocks might
be added to the flowsheet while others might be deleted. It is necessary to
keep the profile database updated with the changing flowsheet. The Update
feature in the Profiles Editor facilitates this and is available when the editor is
launched from within Aspen Utilities.
Note: The Update button is not available in the standalone Editor launched
from the Start Menu.

18

2 Data Editors

When you click Update on the Editor Menu bar, you are first asked to select
the profile that you wish to update:

Select the appropriate choice and click OK. Here we select Demand profile as
an example.

2 Data Editors

19

Select Ports for Demand Profile window appears:

To add a profile, select the equipment and port in the left-most two panes
and then click Add. The newly added profile will be displayed in the Selected
Ports list in the form Equipment*Port.
To remove an existing profile, select it in the Selected Ports list and click
Remove. When you close the form the selected profile is removed from the
grid.
Note: You need to click Save on the Editor Command bar to save your
changes in the Profiles database.
The following list contains brief descriptions of fields shown in the Update
window:

20

Blocks contains all blocks in the current flowsheet.

Ports contains all possible profile variables associated with the selected
block.

Selected Ports current selected profile variables and those in the


profile database.

Add/Remove Add/Remove port to/from the Selected Port column.

Configure the Configure new ports window appears when you click
Configure after new ports are added. In this window, you can select the
display unit of measurement and categorize the selected ports into
predefined areas. After clicking OK, the newly added/removed profile on
the grid appears/disappears.

2 Data Editors

This window will only appear for newly added profiles and will close upon
completion of last new profile configuration.

Filtering Profile Data


For a large flowsheet, there could be many demand and availability profiles,
in multiple periods. In such cases it may be difficult to locate specific profiles.
The profile filtering feature addresses this issue.
You can filter the profile data by area, equipment, or period.

By Area
Click on the area filter displays a drop-down list with all defined areas listed.
Select an item to view data relating to a specific area or to all areas.

By Equipment
Click on the equipment filter displays a drop-down list with all items of
equipment listed. Select an item to view data relating to a single piece of
equipment or to all equipments.

By Period
Click on the period filter displays a drop-down list with all periods listed.
Select an item to view data relating to a single period or to all periods.
Note: The equipment filter and the period filter can be used together.

2 Data Editors

21

Viewing Profiles
In addition to the equipment view of profile data, you can click on View in the
main command bar in the editor and switch to period view.

Equipment View

22

2 Data Editors

Period View

2 Data Editors

23

Printing Profiles
Demand and equipment availability profiles can be viewed and printed in
HTML format. The Print preview window appears when you click Print on
the Editor Menu bar. This is the HTML view format of the selected profile.
Click Print on the Print preview window, the report will be sent to the
printer. Meanwhile, a Save As dialog box appears which allows you to save
the report.

24

2 Data Editors

Saving and Transferring Profile Data


After changing demand and equipment profiles, save the changes to the
Profiles database by clicking Save on the Command bar.
In order for optimization to use the modified profile data, you also need to
transfer the profile data to the Interface database. This is done by clicking
Commit on the Command bar. Commit also saves the profile data to the
Profiles database:

2 Data Editors

25

Selecting a Case
Each Profiles database can contain many cases, which may represent different
operating scenarios for the utility plant. When the Profiles editor is first
launched, the profile data in the default case is displayed, as shown below:

You can display, edit, and transfer profile data in other cases by selecting a
different case in the drop-down list.

26

2 Data Editors

Editing a Case
Each case contains a set of demand profiles and a set of availability profiles.
The Demand and Availability profiles that comprise a case can be changed
with the Edit Case dialog box shown below. This case editing capability,
along with other case management features, allows you to easily carry out
What-if analyses when multiple operating scenarios exist in the utility plant.
The following dialog box is displayed when you click Edit on the Editor Menu
bar:

2 Data Editors

Demand profile all demand profiles are listed in the drop-down list and
the current demand profile is highlighted.

Availability profile all availability profiles are listed in the drop-down


list and the current availability profile is highlighted.

Select Period Set all period sets are listed in the drop-down list and
the current period set is highlighted.

27

Copying a Case
Copy case is used to copy an entire case to a new case. This is also an easy
way to generate a new case. Clicking Copy in the Editor Menu bar displays
the following dialog box:
Case Frame

Profile frame

Period set
frame

Case Frame

Name the name for the new case.

Description the new case description.

Profile Frame

Copy Profile (check box) - Indicates that the current demand and
availability profiles, listed here, should be copied to the new case.

ID - The demand and availability profile ids for the new case.

Name - The demand and availability profile names for the new case.

Description - The demand and availability profile descriptions in the new


case.

Period Set Frame

28

Copy Period Set (check box) - Indicates that the current period set,
listed here, should be copied to the new case.

ID - Period set ID for the new case.

Description - Period set description for the new case.

2 Data Editors

Exporting a Case
Export case is used to Import/Export the case from/to an external source
(database or data source file). The Select database to import/export case
window appears when you click Export on the Editor Menu bar:

Select the correct location in Look in drop down list to find the external data
source file you want to import/export.

2 Data Editors

29

After a source has been selected, the Import/Export Case window displays:

All cases in the current profile database are listed in the left column. All the
cases in the external database are listed in the right column. From here, you
can decide which case or which profile in the case to export or import.

30

2 Data Editors

Changing the Location of the Databases


You can change the location of the Aspen Utilities databases by clicking
Configure on the Editor Menu bar:

Browse to each of the Profile, Tariff, Demand and Interface databases and
click OK.
The Set for all users checkbox is used to set the same database location for
all users. When this is unchecked, only Registry values in
HKEY_CURRENT_USER are set. When this is checked, Registry values in both
HKEY_CURRENT_USER and HKEY_LOCAL_MACHINE are set.

2 Data Editors

31

Tariff Editor
Optimization in Aspen Utilities is all about cost saving on utilities, i.e.,
minimizing the total utility cost during the plant operation. The input cost data
to Aspen Utilities is the price of each purchased or sold utility. The Tariff
editor is used to enter this information. This Tariff data is stored in an Access
database (TariffData.mdb). As in Profiles data, you must transfer the data to
the optimizer before an optimization run takes place.
The tariff structure defined in Aspen Utilities contains two components, the
Contract and the Tier. In the tariff editor, you define a Contract in Contract
Definition Table for each utility purchased or sold. For each contract, you
create one or more tiers to define the actual utility price. In many cases,
utility tariffs vary non-continually with usage or usage rate. To handle these
types of contracts, multiple tiers are used to define various price structures in
a utility contract.
In general, follow below steps to use the Tariff Editor:

32

Open the Tariff editor from the Optimization menu.

Make the necessary changes to the contracts and tiers.

Click Save to save the data in the Tariffs Database.

Click Commit to save the data in the Tariff database and to send the data
to the optimizer.

Click Exit to close the editor.

2 Data Editors

Accessing the Tariff Editor


The Tariff Editor is accessed from the Optimization menu in Aspen Utilities
Planner by clicking Editors, then clicking Tariff on the Aspen Utilities
Planner Data Editors Menu bar.

2 Data Editors

33

The following window appears after clicking Tariff:

All contracts are listed in the upper-half of the table, and the tiers of the
selected contract are listed in the lower half of the table. You can add and
delete contracts and tiers by using Add and Delete on the Command bar.

34

2 Data Editors

Adding Contract
When new purchased or sold utilities are introduced into the flowsheet, you
will need to add a new contract. To add a new contract, right click the mouse
somewhere in the top table and select Add contract. Alternatively, you can
click the arrow on Add and select Contract in the drop-down menu:

To edit an existing contract, double-click on a selected field to enter edit


mode.
To delete an existing contract, click on the relevant contract in the contract
definition table, then either right click the mouse and select Delete Contract,
or click the arrow on Delete and select Contract in the drop-down menu.
For each new contract, you need to provide a unique Contract ID. You must
also specify the Block and Port that the utility represents in the flowsheet.
Click on the drop-down list in the Block and Port fields to select blocks and
ports.
The following data is required for defining a contract:

2 Data Editors

Contract ID you must supply a unique name for the contract.

Block the name of the block (usually a feed or demand block) in Aspen
Utilities flowsheet which uses or provides the utility in the contract. The
previous example shows a Block name of FuelFeed, which is a unit
operation in the example file, example.auf.

35

Port a drop-down list from which you select the port in the block that
provides or uses the utility in the contract. The previous example shows a
Port name of FuelOut1, which is a port name in unit operation FuelFeed in
the example file, example.auf.

Buy/Sell this allows you to specify whether the utility is bought or sold.
In the previous example the utility is bought.

Utility Type a drop-down list from which you select one of three utility
types: Fuel, Electricity, or Steam. In the previous example the utility type
is Fuel.

Use Forecast allows you to specify if a forecast is to be used. This is


very important if there are (for example) annual limits associated with the
contract. If Yes is selected, additional data is required.

Used to Date - this input is only enabled if a Forecast is used. You must
enter the amount of utility used from the start of the contract period to
the current date.

Forecast - this input is only enabled if a Forecast is used. You must enter
a forecast of the amount of utility used between the end of the run period
and the end of the contract period.

Do Peak a peak contract is defined as a contract in which the cost is


linked to the peak usage. Select Yes to define a peak contract, No
otherwise.

Peak Price enter here the peak cost in the contract, in units of
monetary unit/usage. Valid when Do Peak is Yes.

Peak Value specify the peak usage value. For Usage type contracts
(Rate/Usage field), this is the maximum amount of the utility used so far.

Disabled a contract can be temporarily disabled so that it will not be


used in the optimization.

Rate/Usage you can select how the contract is controlled, on an hourly


basis or on a total usage basis. If the contract is controlled on a total
usage basis, then it is advisable to use a forecast.

Unit you can select the unit of measure for data entry and display.

Editing a Contract
Edit mode is entered when you double-click in any grid cell.

36

2 Data Editors

Deleting a Contract
To delete a contract, select a contract in the contract definition table and click
Delete | Contract on the Command bar:

Alternatively, select a contract in the Contract Definition table, right click the
mouse in any cell, and select Delete Contract.

2 Data Editors

37

Adding Tiers
You can add, edit, or delete tiers associated with a particular contract the
same way as for contracts. To see the tiers associated with a particular
contract, click on a Contract ID in the top Contract Definition table.
To add a tier for a contract, click Add on the Editor Menu bar, and then select
Tier from the drop-down menu (or right-click the mouse and click Add tier) a
new row is generated in the Tier Definition table. Alternatively, select a
contract, right click the mouse in any cell of the tier in the Tier Definition
table, and select Add Tier.

The following data is required to complete a tier definition:

38

Tier ID a unique identifier supplied by you.

Variable Cost the cost of utility per unit of use. The base unit is the
same unit of measure defined for the related contract. In this case we
would need to add the cost per GJ of fuel.

Fixed Cost the fixed cost portion of the contract, if any. Enter 0 if there
is no fixed cost (you cannot leave this field blank).

Min Rate the minimum amount of the utility that can be used in an
hour. This field is used only if the contract is controlled by Rate. If the
contract is controlled by usage, enter 0 (you cannot leave this field blank).
If the field is disabled, any entry here is not being used in optimization.

Max Rate the maximum amount of the utility that can be used in an
hour. This field is used only if the contract is controlled by Rate. If the
contract is controlled by usage, enter 0 (you cannot leave this field blank).
If the field is disabled, any entry here is not being used in optimization.

2 Data Editors

Min Usage the minimum amount that can be used within this tier. This
field is active if the contract is controlled by Usage. If the contract is
controlled by rate, enter 0 (you cannot leave this field blank). If the field
is disabled, any entry here is not being used in optimization.

Max Usage the maximum amount that can be used within this tier. This
field is used only if the contract is controlled by Usage. If the contract is
controlled by rate, enter 0 (you cannot leave this field blank). If the field
is disabled, any entry here is not being used in optimization.

Priority the priority order of the tiers considered in optimization. We


recommended you use integer numbers starting from 1. The lower the
number the higher the priority. For example, the optimizer is set to
maximize the use of a tier with priority 1 before using a tier with priority
2. When two tiers have same priorities the optimizer is allowed to use any
of the two or both.

Time dependent if the variable cost of a tier varies with time, select
Yes, if not select No. When Yes is selected, Variable Cost by Period table
appears below the Tier Definition table. Enter the variable cost for each
period.

Editing a Tier
Edit mode is entered when you double-click in any grid cell.

Entering Tariff Cost Equations


In many cases, the cost for a particular utility can be broken down to several
contributing cost components. For example, electricity cost typically consists

2 Data Editors

39

of a fixed standing charge, taxes, a unit price, delivery cost, etc. The fixed
and variable cost for each tier can be calculated by combining these individual
cost components.
In order to do this, you need to input the individual cost components and the
equations that use the cost components, for each tier.

Adding Utility Cost Components


1

Click Costing on the main command bar in the combined editor and the
cost component form is displayed:

Enter the name, description, and value for each cost component in the
grid.
Note: The names of the cost components cannot be duplicated. In
addition, the names cannot contain square brackets ([ and ]).

Editing Utility Cost Components


Edit or change data by typing in the cell.

Deleting Utility Cost Component


Delete a component by selecting the record and pressing the Delete key. A
confirmation dialog is displayed to verify the change.

40

2 Data Editors

Note: Deleting a cost component that is referenced in an equation will cause


errors during the equation evaluation. Therefore be careful when deleting cost
components and be sure to remove any references in the Cost Equations.

Saving Utility Cost Components


Click OK to save changes and close the form. Click Cancel to discard changes
and close the form.

2 Data Editors

41

Accessing the Tier Cost Equation Form


Cost equations can be entered for each tier when the individual cost
components have been added. Cost equations can be entered for the fixed
cost, the variable cost, or both.
The cost equation input form can be displayed in two ways:

42

Click Equation on the main command bar.

Right click the mouse in the fixed or variable cost cell in the tier table and
select Cost Equations from the context menu.

2 Data Editors

Adding a Tier Cost Equation


There is a slight difference depending on how the Cost Equation form is
launched. When Equation is clicked the entire table is displayed with no
specific record highlighted. When the Cost Equations menu item is
selected from a tier cell, the record for this tier is highlighted in the table. If
no cost equation exists, one is automatically added, as shown below.
In this screenshot, the Cost Equation form is launched from Contract Natural
Gas, tier Tier1 and the Variable Cost cell. A new record is added automatically
and you only need to enter the Equation and the optional Notes.

When the equation form is launched by clicking Equation, you need to


manually enter the Contract, Tier, and Type by selecting from the drop-down
lists.

Entering a Tier Cost Equation


When a record is selected in the Cost Equation table, the equation string is
displayed in the Cost Equation = textbox beneath the table. Edit the
equation in the textbox. To display a list of cost components, type an open
square bracket ([) and a dropdown list is displayed containing all cost
component names defined in Tariff cost components form. Scroll to the
desired cost component and select it by pressing the Space bar or by doubleclicking on it in the list.

2 Data Editors

43

Note: The equation cannot be more than 65535 characters. If this becomes a
limitation, Aspen Utilities recommend using shorter cost component names to
reduce the length of the equation string. You can provide a meaningful
description for the cost component in the Notes field; this description is
shown when the cost component is selected.
You can use any functions or mathematical operators that are recognized by
Microsoft Excel since Excel is used to evaluate the equation. When you click
on the Value cell the equation is evaluated and the result will be displayed.
The following screenshots illustrate how to select cost components, their
descriptions, and building an equation:

Typing a left square bracket [ displays a list of all defined cost components.
The text entered in the Notes field is displayed in the tool-tip window.

44

2 Data Editors

Pressing the Space bar or double-clicking on the name in the list substitutes
the name into the equation and closes the bracket.

Editing a Tier Cost Equation


Edit or change equation by typing in the text box.

2 Data Editors

45

Deleting a Tier Cost Equation


Delete a cost equation by selecting the record and pressing the Delete key. A
confirmation dialog is displayed to verify the change.

Saving a Tier Cost Equation


After editing the cost equation in the text box, you can close the Tariff Cost
Equations dialog box directly and the new edited cost equation will be saved
automatically. This also means there is no cancel that discards changes.

Deleting a Tier
To delete an existing tier, select the desired contract in the top table, then
select the desired tier in the Tier Definition table, and click Delete | Tier
from the Command bar. Alternatively, select the tier, right click the mouse in
any cell, and select Delete Tier from the context menu.

46

2 Data Editors

Saving and Transferring Tariff Data


After you add, edit, or delete contracts and tiers, you can save the changes in
the Tariff database by clicking Save on the Command bar.
In order for optimization to use the modified tariff data, you need to transfer
the tariff data to the Interface database. This is done by clicking Commit on
the Command bar. Commit also saves the tariff data to the Tariff database:

2 Data Editors

47

Printing Contracts and Tiers


Like the Profiles editor, the Tariff editor also allows you to view and print the
contracts and tiers in HTML format. The following window is displayed by
clicking Print on the Menu bar:

When you select and click OK, the corresponding report print preview is
displayed. Click Print on the Print preview window, the report will be sent
to the printer and at the same time a Save As dialog box will be loaded which
allows you to save the report.

Demand Forecasting Editor


The Demand Forecasting Editor is used in conjunction with two Access
databases to calculate utility demands from plant production rates. The
equations relating utility demand to production rate are stored in an Access
database, DemandData.mdb. The calculated utility demands are stored in a
second access database, ProfileData.mdb.
The DemandData.mdb file for a specific application must be pre-configured
before the Demand Forecasting Editor can access it. Refer to Appendix 1
Configuring the Demand Forecasting Editor for information how to do this.
The discussion here assumes the Demand database has been configured.
In general, follow below steps when using the Demand Forecasting Editor.

48

Click Optimization | Editors from the Aspen Utilities menu to open the
Demand Forecasting Editor or launch the standalone editor from the Start
menu. Click on DFE in the command bar.

Make the changes required to the demand and availability profiles.

Click Calc in the Command bar to calculate the utility demands. The
running status bar shows the progress.

Click Save to save the data. This saves the utility demands to the Profiles
database (ProfileData.mdb) and updates the production parameter
information in the Demand database (DemandData.mdb).

Click

At any time you can click on


(in the lower right-hand corner) to view a
log file detailing the status of the Demand Forecasting Data and
Calculations.

to close the editor.

2 Data Editors

Accessing the Demand Forecasting Editor


The Demand Forecasting Editor can be accessed by clicking DFE in the Aspen
Utilities Editor, launched from Start | All Programs | AspenTech | Process
Modeling V7.3 | Aspen Utilities Planner | Editors.
The following editor appears:

2 Data Editors

49

Calculating Utility Demands


1

50

Enter the following data to calculating utility demands:


o

Number of Periods the number of periods to calculate.

Start time the starting time for the first period.

Start date the starting date for the first period.

Period Length the length of each period in hours.

Modes select the mode of operation for the period for each process
unit that has multiple modes of operation, using the drop-down list.

Inputs the value of each production parameter for each period


(e.g., production flow rate).

Click Calc to calculate the utility demands. The calculated utility demands
can be seen in the lower pane of the window:

2 Data Editors

Saving Utility Demands


Click Save to save the calculated utility demands to the Profiles database
(ProfileData.mdb) and to update the production parameter information to the
Demand database (DemandData.mdb).

Modifying Demand Equations


Go to the bottom pane and use the scroll bars to search for the utility demand
you want to change. Click Edit next to the Unit column to see the equation
editor. The equation editor for the utility HP Steam Use is shown here:

2 Data Editors

51

Demand Forecasting Equation Editor Layout


The Equation Editor contains two fields:

Equation Editor

Equations Viewer

Equation Editor
The Equation Editor field is for you to edit demand forecasting equations. The
table at the top contains all of the equations that have been defined. When
you click on an equation in the grid, the equation definition is displayed in the
below text box.
The equations with the Demand check box selected at the top table means
they are the equations for utility demand.
In the example above the HP Steam Use equation contains two variables:
[cvY1] and [cvY2]. Variables are contained with square brackets [ ].
Variables can be defined as values (e.g., 5, Mode1, True), or other
equations. Variables that represent equations are displayed in the table at the
top and all other variables are displayed by clicking Variables.

Equations Viewer
You can view the equations defined in this field and evaluate them. Select the
variable you want to see from drop-down list and the equation it represents is
displayed in the text box at the bottom. In this field, you can only check the
equations but cannot edit. In the example above, [cvY1] is selected in the
drop-down list and the equation it represents seen at the bottom. You can
evaluate the equation by clicking Evaluate next to the equation.

Using the DFE Equation Editor


An example will show how to use the DFE Equation Editor. The example will
create the HP Steam Use equation, starting with nothing.
The HP Steam use is given by:

If the season is winter:


HP Steam Use = 6 + 0.2*X1 + 2*X1^2
Where X1 is the propylene production rate. And if X1 is less than or equal
to zero, it returns 0.
If season is not winter, HP Steam Use = 90 tonnes/hr

If the Acetic acid mode is Lean:


HP Steam Use = 0

Click on Edit next to the unit of measure for HP Steam Use.


The Equation Editor window appears:

52

2 Data Editors

Notice that there is no equation defined for HP Steam Use. The first step is
to create the equation.
2

Click Add Equation and fill information requested in Add Equation


dialog box:

If you need to set this equation as a utility demand, then select the Set
this equation to be a utility demand check box.
3

2 Data Editors

Click OK and you return to the Equation editor ready to create the
equation for cvY1:

53

The basic equation is given by: 6 + 0.2*X1 + 2*X1^2 where X1 is the


propylene production rate. Because we want this to be evaluated only
when the season is winter we can put an IF statement around the
equation:
IF("[SEASON]"="(SEASON.Winter)",6+0.2*[X1]+2*[X1]^2,0)
Note: In this example, SEASON is case sensitive, The value in the
equation should use the same case as what is displayed in the Variables
table (click Variables to open). If you use SEASON.WINTER in the
equation, the equation will not work properly.
Also, we want to return 0 if X1 is less than or equal to zero. We can create
a nested IF statement to do this:
IF("[SEASON]"="(SEASON.Winter)",IF([X1]>0,6+0.2*[X1]+2*[X1]^2,
0))
And if season is not winter, the value of HP Steam Use is 90 tonnes/hr. So
the final equation should be:
IF([SEASON]=(SEASON.Winter),IF([X1]>0,6=0.2*[X1]+2*[X1]^2,
0),90)
Begin by typing to the first left square bracket [. When you type the left
bracket, a list is displayed with all of the variables known to DFE:

54

2 Data Editors

Scroll down to SEASON and double-click.


The Equation description is shown as a small tool-tip window when a
variable is clicked:

2 Data Editors

55

Notes:
1. Notice that the right bracket is automatically inserted for you.
2. Notice that the [SEASON] is enclosed in double-quotes because it
contains text.
5

56

Continue editing:

2 Data Editors

Note: The parentheses ( ) around the value of the text variable:


(SEASON.Winter)
When values are substituted for variables, DFE places parentheses around
the variable contents. For text values the brackets signifying variable
names are inside the double quotes, resulting in the parentheses being
inside the double quotes after substitution. Therefore, you must add
parentheses around all text values being compared.
6

Click Variables to see the variables defined for DFE. Refer to the
section Displaying Equation Variables for more information.
Finally, complete the equation:

2 Data Editors

57

Here, X1 is the propylene production rate. The variable values substituted


into the equation are those seen by clicking Variables. Refer to
Displaying Equation Variables for more information.
7

58

Click Evaluate to evaluate the equation:

2 Data Editors

If there is an error, a red exclamation point is displayed. Holding the


mouse pointer over the exclamation point shows the error in a tool-tip
window.

2 Data Editors

59

Note: Not all errors are caught this way. Some equation errors are not
caught until Microsoft Excel is evaluating the equation. In these cases you
will see a large negative number being displayed.
8

60

You can edit other equations for HP Steam Use in a similar fashion.

2 Data Editors

2 Data Editors

Finally, the HP Steam Use is created in the middle text box.

61

Note: Newly created equation variables like cvY1 will be displayed


automatically in the drop-down variable list after entering left square
bracket [.
10 Finally, click Evaluate for HP Steam Use to check the equation entered.
11 Click OK to save your data and close the Equation Editor

Tips for Creating Equations


Here are some tips for creating equations:

Variable substitution and equation evaluation is faster if you enter the


coefficient values directly in the equation, rather than using variables. For
example:
3.1 + 10.22*[X2]
will evaluate faster than
Var_A + Var_B*[X2]

62

2 Data Editors

This will be more noticeable as the number of equations and variables get
larger.

2 Data Editors

The maximum length of an equation string is 65535 characters, including


all spaces, brackets, and variable names. If you have a longer equation,
create multiple equation variables, an equation can be made up entirely of
equation variables and that equation can be referenced by a single
variable in another equation. That way, extremely long equation strings
can be created; there is no limit.

63

Adding an Equation
To add an equation, first create the equation variable by clicking Add
Equation and the Add Equation dialog box appears:

Enter the Equation ID and Equation description. The Equation ID becomes the
equation variable name seen in the equation drop-down list in the Equations
Viewer field and drop-down variable list.

64

2 Data Editors

Click OK to return to the equation editor. The new equation is selected and
can be entered in the text box in Equation Editor field:

Note: When adding an arbitrary equation, you must to uncheck the Set this
equation to be a utility demand checkbox. When checked, the system
assumes you are creating an equation that is linked to a utility.

Deleting an Equation
Delete an equation by selecting an equation and clicking Delete Equation.
You will be asked to confirm the deletion.

2 Data Editors

65

Displaying Equation Variables


You can view the variables that have been defined by clicking Variables:

This table contains variables that come from the Demand and Profiles
databases as well as user-defined variables. User-defined variables include
production rate variable, mode variable and user variable.
To create a user defined variable, click Add. The Add Variable dialog box
appears:

Notes:

66

2 Data Editors

Variable names may not contain square brackets [ and ] since these are
used by DFE to enclose variable names.
Variable values can be changed for any variable but only values for user
variables are saved when you click OK. This allows you to temporarily
change production rates, modes, etc., while evaluating an equation.
Once created, a variable name and description cannot be edited. You must
delete the variable and recreate it.

Demand Forecasting Variable Location


The DFE variables are located in the following tables in the Demand database,
DemandData.mdb:
Variable Type

Demand Database Table

Production rates

DemandForecastingInput

Mode variables

tblModes

Equation variables

tblEquationDefinition

User variables

tblUserVariables

Using the Variable Filter


You can shorten the list of variables displayed in the drop-down variable list
by clicking Variable Filter:

2 Data Editors

67

Check the variables that you want to display in the drop-down variable list
when a left bracket [ is typed in the equation editor.

Modifying Independent Variables in


Equations
With the exception of user variables, the values of independent variables can
only be changed within the Microsoft Access database editor. The default
Demand database, DemandData.mdb, is located in Installation
Drive:\Documents and Settings\All Users\Application
Data\AspenTech\Aspen Utilities Planner V7.3\Example Databases.
Refer to the Changing the location of the databases section earlier in this
chapter for how to change the location.
Click Variables to display all variables. Find the variable description of
interest and get the Variable name.
Open the appropriate table in the Demand database (refer to Demand
Forecasting Variable Location section), find the variable name, and change its
value.

68

2 Data Editors

Calculating Utility Demands for Multiple


Periods
If you set the number of periods to be higher than 1, the Demand Forecasting
editor shows an additional column of data for each additional period. The
example below shows a 5-period forecast:

The editor displays the additional columns using default values as inputs for
period length, mode values, and production rates. You can edit these inputs
either manually or by copying and pasting data from Microsoft Excel.

2 Data Editors

69

70

2 Data Editors

3 Optimization Configuration

This chapter describes how to set your input data to achieve specific types of
optimizations. Topics covered are: enforcing hot standby requirements,
configuring startup/shutdown constraints, configuring load shedding, and
obtaining marginal utility costs.
This chapter also describes how to identify optimization errors and gives tips
on how to fix them. Advanced optimizer settings are also discussed here.

Enforcing Hot Standby


Requirements
To enforce hot standby requirements, it is necessary to indicate which of the
steam generators are to be included within the calculation of hot standby
capacity. This setting is accessed from the Optimization_Settings form for the
block. Right click on the boiler block, for example, and select Forms |
Optimization_Settings from the context menu:

If the block is to be included in the calculation of hot standby capacity, set


DoSteamReserve to True. The default setting is False.

3 Optimization Configuration

71

To enable the hot standby calculations within the optimization:

72

Select Edit Optimization Settings from the Optimization menu in


Aspen Utilities Planner.

Check the Enable hot standby calculations check box.

The hot standby requirement is also set in this dialog box. This value must
be specified in tonnes/hr.

Run the optimization as usual either from the Microsoft Excel Interface or
from Aspen Utilities Planner.

3 Optimization Configuration

If the hot standby constraint cannot be met, the optimization will still
complete but with a lower hot standby capacity.

Configuring Startup/Shutdown
Constraints
It is possible to set start-up and shut-down times and costs within Aspen
Utilities. When carrying out a multi-period optimization, these values are
taken into account to determine the economic profile for utility generation
and/or purchase over the entire optimization timeframe.
Start-up and shut-down times and costs can be provided for most blocks by
accessing the Optimization_Settings form.
To enable startup and shutdown calculations, set the DoStartStop variable to
True. The default for all blocks is False.

You must then specify:

StartUpTime the time taken to start the unit from cold to actually
producing utility.

StartUpCost the hourly cost of starting up the unit.

ShutDownTime the time taken to shut the unit down. It is assumed


that utility is not generated from the start of the shutdown period to the
end of it.

ShutdownCost the hourly cost of shutting down the unit.

3 Optimization Configuration

73

To enable the startup/shutdown calculations within the optimization:

74

Select Edit Optimization Settings from the Optimization menu in Aspen


Utilities Planner.

Check the Enable start/stop calculations check box.

Run the optimization as usual. If an item of equipment is set as available


within the optimization input, the cost for changing the state of that item
of equipment (starting it up if it is currently off or shutting it down if is
currently on) is calculated.

3 Optimization Configuration

Configuring Load Shedding


Aspen Utilities Planner can be used to determine the optimum load shedding
scheme. In order to configure Aspen Utilities Planner for load shedding
optimization, you need to specify which blocks are to be included in the
optimization and their load shedding cost. Follow the steps below to configure
the Aspen Utilities model for load shedding:
1

Specify which blocks should be included in the loadshedding calculation.


This is done by setting the AllowLoadShedding parameter to True in
the AllVariables table. Right click on the block and select Forms |
AllVariables.

Repeat this step until all blocks have been specified.


2

To account for lost production and other related costs, you can enter the
cost of load shedding in LoadShedCost, further down in the AllVariables
table.

You must also provide the availability and demand profiles to be used in
the load shedding calculation. Do this by filling in the OptInputMods table
in the Interface database (Interface.mdb).
An example is shown below. The example also shows multiple profiles
two time periods to be considered in the optimization.

3 Optimization Configuration

75

As a last step of configuration, you create a loadshedding problem by


creating and invoking a script in Aspen Utilities Planner.
Do the following to create a new script:
a Click Add Script at the Flowsheet Level in the Aspen Utilities Planner
Explorer and Enter a name, e.g. SteamLoadShedding.

b Click OK and a text editor is displayed. Enter the text shown in the
screen below. Here, n should be replaced with the number of periods that
are being considered in the load shedding calculation.

76

3 Optimization Configuration

c You can run the script by double-clicking on it in the Contents Pane.


You can also run the script programmatically. For example, you can create
a Visual Basic script function in Excel with the following contents:
Public Sub cmdCreateShed_Click()
On Error GoTo ErrHandle
Set AUapp = Application.Run("GetAMApp")

AUapp.Simulation.Flowsheet.Invoke "SteamLoadShedding"
Exit Sub
ErrHandle:
MsgBox Err.Description
End Sub
5

Run optimization. When the optimization is complete you can check the
solution as usual in Aspen Utilities Planner or create a Visual Basic
function to extract the results from Aspen Utilities Planner to Excel in a
user-preferred format.

Obtaining Marginal Utility Cost


To obtain the marginal cost of utility headers (e.g. steam header, fuel header,
etc.) at the optimal solution you should follow below steps:
1

Display the Optimization Setting dialog by selecting Optimization | Edit


Optimization Settings from the Aspen Utilities Planner menu.

Select the check box Calculate marginal utility costs.

3 Optimization Configuration

77

You must indicate which headers are to be included in the marginal cost
calculation.
3

78

Display the summary table for the desired header by double-clicking on it.
Select True for the IncludeMarginalCost parameter. Repeat this step
until all desired headers are specified:

3 Optimization Configuration

Run the optimization. When the optimization completes the marginal cost
of header is reported in the variable MarginalCost in the summary table of
the header model.

3 Optimization Configuration

79

Identifying Optimization Errors


The Aspen Utilities optimization model is linear and uses a mature integer
linear programming technique do the optimization. In the majority of the
cases the model will run without problems. However, data input errors can
cause optimization failure namely infeasibilities.
Aspen Utilities Planner contains two error diagnostic mechanisms to help
detect optimization errors: presolve checking and error tracking. You can
access optimization error diagnostics from the Optimization menu in Aspen
Utilities Planner:

Click Optimization Error Diagnostics to display the following window:

80

Run Presolve Error Check executes presolve error checking.

Execute Error Tracking Run performs error tracking.

3 Optimization Configuration

View LP Model brings up a list file, (a Dash compilation file for the
model).

View Log file the optimization iteration log, which could contain
infeasibility information if the optimization failure is caused by infeasibility.
This file is displayed at the end of running Presolve Error Check.

Presolve Error Checking


Presolve error checking uses the built-in solver presolve checking function to
identify possible infeasibility errors (for example, a minimum bound is greater
than a maximum bound on a variable).
Below is an example of a typical user input error and presolve checking
report:

This error report indicates that the particular LP problem is infeasible due to
the equation FPort(1, Boiler, BFW), which points to port BFW in block Boiler in
the flowsheet. The infeasibility is that in this case, the lower bound of the
BFW port in the boiler is 75.8 tonnes/hr but the upper bound of connected
stream flow is 30 tonners/hr only. So the Lower Bound is greater than the
Upper Bound.
Therefore, you can correct the incorrect data and then begin your calculation.

3 Optimization Configuration

81

Error Tracking
Apart from the above obvious type of infeasibility, there could be other
infeasibility due to the failure of closing the mass balance on a process block.
This is more difficult to detect and usually cannot be picked up by the solver
built-in presolve mechanism.
In Aspen Utilities Planner, error tracking is carried out by introducing a
balance variable on each mass balance equation which is minimized in the
objective function. When the optimization completes, the problematic
balance equations and corresponding blocks containing the balance equations
will be listed in the simulation message window. This should give an indication
of where to search for faulty limit specifications.
In general, this type of error is much more difficult to detect than the first
type. It requires careful engineering analysis and familiarity with the
flowsheet even after identifying the error by using Error tracking.
The following forms show an example of input error and using the errortracking mechanism to detect it:

82

3 Optimization Configuration

Note: LP Process Steam Generation is 1000 tonnes/hr (much higher than the
maximum boiler steam generation (200 tonnes/hr)).
Although the input is correct in mathematical terms (minimum<=maximum)
and the presolve mechanism does not detect any error, it causes an infeasible
solution when the optimization runs.
An Error Tracking run with the input data has the following output:

3 Optimization Configuration

83

Note: The solution contains objective function values that are very big
numbers. This usually indicates the balance variables are non-zero in some
process balance equations.
In the simulation message window, the error messages indicate that the
balance equation in block HPHDR is not balanced (this becomes balanced only
with non-zero relaxation variables). By inspecting the profiles data, we find
that the LP Steam Generation (LPGEN) is too large and hence causes the
infeasible solution.

84

3 Optimization Configuration

Setting up Options for


Optimization
Multiple Period Run Mode
When running a multi-period optimization in Aspen Utilities Planner, you can
use one of two modes: Simultaneous or MultiRun. The
MultiPeriodRunMode parameter in the Globals Table is set to the desired
mode:

Simultaneous mode means that the entire optimization model covering all
periods is solved simultaneously. This approach can be slow and poses
numerical difficulties when dealing with a large optimization model. However,
under some circumstances (e.g., equipment Startup/Shutdown, when timedependent utility contracts need to be taken into account, etc.), this mode
must be used to satisfy optimization constraints.
MultiRun, as indicated by its name, makes optimization runs as many times
as there are periods defined in the model. Convergence is relatively fast and
robust with this mode. You should use this mode when there is no
requirement to connect one period optimization to another period
optimization.

3 Optimization Configuration

85

Settings for Mixed Integer


Linear Solver
Please refer to the following Optimization Settings dialog box for settings
discussed in this section:

Cut Strategy
Cut strategy is a setting that controls the number of cuts generated in each
branch and bound solution. The following table summarizes the available cut
strategy. You should refer to general Branch and Bound methods for mixer
integer linear programming to understand more about Cuts:
Values for Cut Strategy

86

Description

3 Optimization Configuration

-1

Automatic selection of the cut strategy.

No cuts.

Conservative cut strategy.

Moderate cut strategy.

Aggressive cut strategy.

Cut off Value (Max. Expected Cost)


If you know you are interested only in values of the objective function which
are better than some value, you can specify this value in Cut off value
(Max. expected cost). This allows the Optimizer to ignore solving any nodes
which may yield worse objective values, saving solution time. It is set
automatically after an LP Optimizer command, unless it was previously input
here.
Note: Since cost minimization is the objective in an Aspen Utilities
optimization, the cut off value can also described as the maximum expected
utility cost.

Optimum Gap from Optimality (%)


This determines whether or not the global search will terminate. Essentially,
the global search will stop if:
| MIPOBJVAL - BESTBOUND | <= GAP (%) * BESTBOUND
where MIPOBJVAL is the value of the best solution's objective function and
BESTBOUND is the current best solution bound.
For example, if you enter a 5 (%) here, the global search will stop when a
MIP solution has been found and the Optimizer can guarantee it is within 5%
of the optimal solution.

Presolve Strategy
The Optimizer provides a number of algorithms for simplifying a problem prior
to the optimization process. This elaborate collection of procedures, known as
presolve, can often greatly improve the Optimizer's performance by
modifying the problem matrix, making it easier to solve. The presolve
algorithms identify and remove redundant rows and columns, reducing the
size of the matrix. In most cases this is a helpful tool in reducing solution
times. However, presolve is included as an option and can be disabled by
entering 0 for Presolve Strategy. Here, we have other three options: 1, 2 and
3. 1 means conservative, 2 moderate and 3 aggressive. The default value is 2
(moderate).

3 Optimization Configuration

87

88

3 Optimization Configuration

4 Aspen Utilities On-line


Implementation

Linking with InfoPlus.21 via Aspen Online, Aspen Utilities can be configured as
an on-line implementation. In online mode, Aspen Utilities takes data
automatically from the real-time data historian at certain time intervals and
updates the demand profiles automatically.
One of the main differences between offline implementation and online
implementation is that Aspen Utilities must run unattended. Therefore Aspen
Utilities must be configured to run without user intervention.

Calculating Utility Demand


Targets
The Demand Forecasting Editor (DFE) is normally used interactively to
calculate the utility demands. Since this is not possible in online mode you
must configure it to run in an automatic manner as described in the steps
below:
1

Setup the demand forecasting database, DemandData.mdb.


Refer to Appendix 1 Configuring the Demand Forecasting Editor for the
detailed information on how to configure the demand forecasting
database.

Open the On_Line form. This form is available for all demand blocks and
for the GeneralModel block.
Right click the mouse on one of these block types and select Forms |
On_Line.

4 Aspen Utilities On-line Implementation

89

In this form you need to give the number of inputs (nInputs), its
corresponding ID and input values (array OptInputVar), the number of
process operating modes (nModes), its corresponding ID (array ModeID)
and mode value (array ModeValue). The On_line form is illustrated in the
following example.
In this example, two blocks, FCC and CRU, contribute to the total LP
consumption (LPUSE). The LP consumption correlation for FCC has one
independent variable (FCC_Throughtput) and the correlation for CRU has
two independent variables (CRU_Throughput and CRU_ARO); therefore,
the total number of inputs (nInputs) is 3. Each process has a different
operating mode and thus nModes is 2. The values for ModeID are given as
FCC_Mode and CRU_Mode, respectively (arbitrary, but descriptive). There
are two operating modes for each process and thus nModeValue is 2
respectively. You also need to specify the number of target variables, in
this case the number of LP consumption for nTargets and name of the
contribution from each process (FCC_LPUSE and CRU_LPUSE) for
TargetVariableID.
The calculation result will be displayed and stored in array TargetValue for
each processes.

90

4 Aspen Utilities On-line Implementation

Note: All these names (IDs) must be the same as those defined in the
database.

Specifying Demands for On-line


Optimization
Utility import and export can be varied in an Aspen Utilities on-line
optimization. For instance, natural gas import from the supplier could be
minimized while power export could be maximized.
This might not be the case for other utility supplies and demands. For
example, steam export from production processes cannot be changed due to
fixed production throughput or operating conditions, and steam demand from
production is also fixed due to fixed process throughput.
To handle these situations properly, you must specify which utility
feeds/demand blocks have fixed utility flow at its current value in the
optimization. Specify fixed utility flow by setting the OptInputFlag

4 Aspen Utilities On-line Implementation

91

parameter to True in the On_Line form for the various types of Feed and
Demand blocks and the GeneralModel block.

92

4 Aspen Utilities On-line Implementation

5 Microsoft Excel Interface

You can run Aspen Utilities Planner and view the results from within Microsoft
Excel. This allows you to develop a graphical representation of your flowsheet
and to retrieve and report Aspen Utilities Planner results within Excel. This
chapter describes how to use the Aspen Utilities Planner Microsoft Excel
interface.

Installing the Aspen Utilities


Planner Add-In
The first step is to install the Aspen Utilities Planner Excel Add-In. Execute the
following steps to install the Add-In:
1

Start Microsoft Excel.

Select Tools | Add-ins.

Use Browse to find the Aspen Utilities Planner Add-In, named


utilities240.xla. This file is located in the bin subdirectory of the Aspen
Utilities installation (default location is installation drive:\Program
Files\AspenTech\Aspen Utilities Planner V7.3\bin).

Select utilities240.xla and click OK.


If you previously had installed this Add-In you are asked if you want to
replace the existing reference, click Yes.

When the Add-In installed a new menu item - named Aspen Utilities is
added to the Excel menu bar.

5 Microsoft Excel Interface

93

Aspen Utilities Excel Menu Items

When the Aspen Utilities Planner Add-In is installed, the Aspen Utilities menu
item will be present on the main excel menu bar.

Open Aspen Utilities File used to browse to and select an Aspen


Utilities Planner file (an .auf file).

Show Aspen Utilities make Aspen Utilities Planner visible. By default,


Aspen Utilities Planner is not visible when an Aspen Utilities Planner file is
opened.

Hide Aspen Utilities allows you to hide Aspen Utilities Planner.

Close Aspen Utilities close the Aspen Utilities file and shutdown Aspen
Utilities Planner.

Simulate Flowsheet run a flowsheet simulation. This option is the


same as the run simulation in Aspen Utilities Planner with two important
additions: 1. before the simulation runs, values are sent from the
spreadsheet to Aspen Utilities Planner, and 2. when the run has finished
the latest values are retrieved from Aspen Utilities Planner.

Run Reconciliation runs data Reconciliation.

Optimize Flowsheet runs an optimization. As with Simulate Flowsheet,


values are sent from the spreadsheet to Aspen Utilities Planner before the
optimization and values are retrieved from Aspen Utilities Planner when
the optimization is complete.

Simulation Menu
o

94

Load Simulation Links loads the Simulation Links command bar


and generates the Simulation Links worksheet if it not present.

5 Microsoft Excel Interface

Send Values this option retrieves the values of variables on the


Simulation Links worksheet and sends them to Aspen Utilities Planner

Get Latest Values this option retrieves the latest values from
Aspen Utilities Planner for the variables selected on the Simulation
Links worksheet.

Reconciliation Menu
o

Load Reconciliation loads the reconciliation bar and generates the


Reconciliation worksheet if it not present.

Get Latest Values this option retrieves the latest values from
Aspen Utilities Planner for the variables selected on the Simulation
Links worksheet.

Optimization Menu
o

Get Optimization Results when an optimization run is completed,


the results shown in the Simulation Links sheet are for the first period
only. To view the results from other periods, select this menu item and
input the period number of interest. The flowsheet re-simulates and
the results are displayed for that period.

Editors displays the Profiles and Tariff Data editors.

Refresh Data updates the data shown in the spreadsheet.

At the bottom of the Aspen Utilities menu item is a list of the most recently
opened Aspen Utilities files. This recent file list is discarded when the Add-In
is uninstalled.

Open Aspen Utilities File


An Aspen Utilities file must be opened before any Aspen Utilities menu items
become available and before the Simulation Links worksheet can be
configured.
1

Select Open Aspen Utilities File from the Aspen Utilities menu item.

Use Browse to search for the file you want to open.

Click OK.

The status bar in Excel shows the full path name of the file being opened.
When the file is open the status area message changes to Ready.
If required, you can make Aspen Utilities Planner visible by selecting Show
Aspen Utilities from the Aspen Utilities menu.

Running a Simulation from


Excel
This section describes how to setup Excel to send and retrieve values from
Aspen Utilities Planner.

5 Microsoft Excel Interface

95

Creating a Simulation Links worksheet


Simulation Links is used, as the name implies, to create links between Excel
and your Aspen Utilities Planner flowsheet (the .auf file).
You can add a simulation links worksheet by selecting the menu item Aspen
Utilities | Simulation | Load Simulation Links.
Note: If a Simulation Links worksheet already exists a new one will not be
added.
A blank Simulation Links worksheet is shown below:

There are two sections in the Simulation Links sheet: the left-hand side is
used for sending values to Aspen Utilities Planner and the right-hand side is
used to retrieve values from Aspen Utilities Planner.
Note: A Simulation Links command bar is added to the Excel menu area.
All information is saved with the spreadsheet. If you change the Aspen
Utilities Planner file in certain ways (e.g., renaming a block, removing a block,
changing the model by removing a variables, etc.), some links may become
invalid and these cells are highlighted yellow the next time the spreadsheet is
open. A yellow highlight indicates the block or variable in the simulation link
does not exist in the currently opened Aspen Utilities flowsheet.

96

5 Microsoft Excel Interface

Configuring Blocks and Variables for Input


to Aspen Utilities Planner
To configure blocks and variables to send to Aspen Utilities Planner follow
below steps:
1

Click on the left-hand side dropdown list to display all block names in the
flowsheet as shown below:

Select the block of interest and the name will be added to the first empty
row on the Send Values side.

Click Load Variables (see above figure).

Click on the Variable Name drop-down list to display all the variables
associated with the selected block. Select a variable and its name is
inserted next to the block name in the worksheet. An example of the
variable name list is shown below.

5 Microsoft Excel Interface

97

Enter the desired value in the Value cell.

Continue the above steps until all your input variables are selected. When
the data on the spreadsheet reaches the last couple of rows near the
bottom of the worksheet a line is automatically added.

By default, the value you enter must be in the current unit of measure
defined in Aspen Utilities Planner. You can enter a different unit of
measure in the Unit column (e.g., GJ/hr for energy flow, ton/hr for mass
flow, etc.). The value will be converted to the new unit when it is sent to
Aspen Utilities Planner. If you select the menu item Aspen Utilities |
Simulation | Send Values, the values are converted and sent without
executing simulation. This is done automatically when you simulate or
optimize the flowsheet. Take care when entering a different unit of
measure, that the string you enter is known to Aspen Utilities Planner.

Configuring Blocks and Variables for


Retrieval from Aspen Utilities Planner
Configuring blocks and variables to retrieve from Aspen Utilities Planner is
very similar to the procedure outlined in the previous section. Blocks and
variables to be retrieved from Aspen Utilities Planner are configured on the
right-hand side of the spreadsheet. Follow below steps:

98

Click on the third drop-down list from left to display all block names in the
flowsheet:

Select the block of interest and the name will be added to the first empty
row on the Retrieve Values side.

Click Load Variables (see above figure).

5 Microsoft Excel Interface

Click on the Variable Name drop-down list to display all the variables
associated with the selected block. Select a variable and its name is
inserted next to the block name in the worksheet. An example of the
variable name list is shown below:

By default, the displayed value is in the current unit of measure defined in


Aspen Utilities Planner. You can enter a different unit of measure in the
Unit column (e.g., GJ/hr for energy flow, ton/hr for mass flow, etc.). The
value will be converted to the new unit when it is retrieved from Aspen
Utilities Planner. If you select the menu item Aspen Utilities |
Simulation | Get Latest Values, the values are retrieved and converted
immediately. This is done automatically when you simulate or optimize the
flowsheet. Take care when entering a different unit of measure, that the
string you enter is known to Aspen Utilities Planner.

5 Microsoft Excel Interface

99

Mapping Variable Values to the Excel


Flowsheet
There are many advantages when using Microsoft Excel to run Aspen Utilities
Planner. One advantage is that it allows you to decompose complex
flowsheets into sub-flowsheets and draw them on separate worksheets. You
can then map variables from the Simulation Links worksheet to the cells in
the sub-flowsheet drawing in an intuitive way. A simple boiler model is used
here to illustrate this:
1

Starting with a new blank worksheet, draw a boiler and associated


streams using the drawing tools provided with Excel. It might look like:

Place the mouse cursor in the cell that you want to map to a Simulation
link and type = in the cell (cell E17 in the example above).

Switch to Simulation Links worksheet and click on the Value column for
the variable to map. Press the Enter key and Excel links the cells in the
two worksheets.
Note: The value column you should choose for the variable to map is the
value column in Retrieve latest values from Aspen Utilities form on the
right side.

100

Repeat these steps until all Simulation links have been mapped to your
flowsheet drawing.

5 Microsoft Excel Interface

By doing this, cell values in your flowsheet drawing will change when the
variable values change in the Simulation Links sheet that is, when Get
Latest Values is selected or a flowsheet simulation or optimization is
performed.
Note: The unit of measure is not always shown after mapping. The units
fields in the table are used to display/send values in units of measure that
are different than the flowsheet. If the Units field is blank, values are sent
to or retrieved from the flowsheet with no unit conversion. If the Units
field has a string (UOM), the value is sent to or retrieved from the
flowsheet along with the UOM. Aspen Modeler attempts to convert the
value.

Running Data Reconciliation


from Excel
Many factors can affect the quality of data collected from the plant. Some
places in the plant may not have meters installed and others may have
meters that are malfunctioning. These data uncertainties cause the mass and
energy balances in the plant model to become unbalanced. In order to
reconcile the values calculated by the flowsheet models with those collected
from the plant, a data reconciliation tool is provided in Aspen Utilities. Before
using this tool in Aspen Utilities, you are encouraged to read the related
sections in the Aspen Custom Modeler User Guide. From the Aspen Utilities
Planner menu select Help | Aspen Custom Modeler Topics. Refer to the
online help on Estimation in this guide.

5 Microsoft Excel Interface

101

With the Aspen Utilities Planner Excel Interface, you can set up and run the
data reconciliation problem.

Accessing Reconciliation Worksheet


You set up the reconciliation problem in a Reconciliation worksheet. If your
existing Excel file does not contains a Reconciliation worksheet, you can
create one by selecting the menu item Aspen Utilities | Reconciliation |
Load Reconciliation:

A new worksheet named Reconciliation will be added to your workbook:

The Reconciliation worksheet has a Reconciliation command bar that is used


to set up the reconciliation problem. This is described in the next section.

102

5 Microsoft Excel Interface

Configuring Blocks and Variables for


Reconciliation
To reconcile the flowsheet model, you must specify which data are measured,
the quality of the data, and which model variables need to be reconciled.
Follow below steps to set up the information in the Reconciliation worksheet:
1

Click on the Model Names drop-down list to display all block names in the
flowsheet. Select the block in which the data measurement is located.

Click Load Variables.

Click on the Variable Name drop-down list to display all variables for the
selected block. Select the variable name that represents the measured
data.

The block and variable names along with its data will appear in the
worksheet as shown below:

Repeat the above steps until all desired variables are configured.
The columns in the Reconciliation worksheet are:
o

Value - shows the current value in the flowsheet and will show the
reconciled value after the reconciliation run is executed.

Units - indicates the unit of measurement used for the selected


variable in the flowsheet and can be changed. Take care when
entering a different unit of measure, that the string you enter is known
to Aspen Utilities Planner.

Estimate - is where you enter the meter reading or the estimated


number.

Variance/Relative/Confidence - indicates the type of weighting


methods used in the reconciliation. The weighting method can be
changed by selecting from the Weighting Method list on the
Reconciliation command bar.

5 Microsoft Excel Interface

103

Add - indicates whether the selected variable in the reconciliation


worksheet is added into the model and reconciled. Y means to include
the variable and N means to exclude the variable.

Spec - indicates the current specification of the selected variable:


Fixed or Free.

Note: The reconciliation problem must include at least one fixed variable.
o

Lower Bound and Upper Bound - indicate the range that variables
are allowed to vary during the reconciliation run.

Absolute Error - indicates the absolute difference between the


estimated value and the calculated model value.

% Error - indicates the percentage difference between the estimated


value and the calculated model value.

Once the reconciliation sheet is configured, you can reconcile the flowsheet by
selecting the menu item Aspen Utilities | Run Reconciliation.
Here are a few tips that may help you set up the reconciliation problem:
1

If an associated variable that is connected to a reconciled variable is fixed


then include the associated variable with a small weight.
For example, if fuel molar flow is measured and the fuel mass flow is fixed
in the simulation, include both fuel mass flow and molar flow in the
estimation. The weight of fuel mass flow should be small.

Interrelated variables cannot be reconciled independently.


For example, a mass balance equation would have the form: A + B + C =
D. If A, B and C are reconciled in the above equation and D has a status of
fixed in the simulation then include D with a small weight in estimation.

Do not constrain free variables and place sensible bounds on reconciled


variables (fixed variables).

Make sure the steady state simulation runs OK before using data
reconciliation.

Running Optimization from


Excel
The Aspen Utilities Planner Excel interface also allows you to optimize your
flowsheet. As is the case in optimizing from within the Aspen Utilities Planner
product, you should configure the utility demands and equipment availability
profiles as well as tariff data using the Profile and Tariff Editors. These can be
accessed by selecting the menu item Aspen Utilities | Optimization |
Editors.
In addition, the Excel interface has two built-in functions that are
automatically called before and after the optimization: BeforeOptimise and
FlowsheetUpdate. These are present to allow any user-specific tasks before
and after flowsheet optimization.

104

5 Microsoft Excel Interface

Performing User Specific Tasks before


Optimization
You may want to conduct some specific tasks before doing an optimization,
such as running simulation, reconciling the flowsheet, etc. The BeforeOptimise
function can be used to do these tasks. Follow below steps to execute
BeforeOptimise function:
1

In Excel, select Tools | Macros | Visual Basic Editor to display the


Excel Visual Basic Editor.

Double-click on the Simulation Links sheet in the tree view and add the
function BeforeOptimise in the source code window as shown below:

You can put the tasks you want to run before optimization inside this
BeforeOptimise function. These tasks may, of course, call Excel functions,
other functions you create, or Aspen Utilities functions.

5 Microsoft Excel Interface

105

Producing Optimization Results and Tariff


Information from Aspen Utilities
One of the most common tasks is to retrieve optimization results from Aspen
Utilities Planner back to Excel. Follow these steps to configure a worksheet to
retrieve Aspen Utilities Planner results.
1

Click Tools | Macros | Visual Basic Editor to display the Excel Visual
Basic Editor.

Double-click on the Simulation Links sheet in the tree view and add
function FlowsheetUpdate in the source code window as shown below.
Here, functions MPUpdate and CostsUpdate are two built-in functions in
the Aspen Utilities Planner Excel Add-In that transfer the results and
costing information from Aspen Utilities Planner to Excel worksheet:

Add a worksheet in your workbook and name it MP Results. Configure


the worksheet so it has the column header names, highlighting, etc., as
shown below.
An even easier way to add the worksheet is by running an optimization
(select Aspen Utilities | Optimize Flowsheet). When the optimization
completes, the function MPUpdate called in FlowsheetUpdate will
automatically create and configure the MP Results worksheet.

106

5 Microsoft Excel Interface

Enter the Block ID and Port ID and corresponding legend.


Refer to the Configuring Blocks and Variables for Retrieval from Aspen
Utilities section earlier in this chapter for how to determine valid Block and
Port IDs.

Enter the desired unit of measure you want the value displayed in (the
Units column) and give the conversion factor that converts the value from
the current unit in Aspen Utilities Planner to this unit (the Conversion
Factor column):

Value 2 CF Value1
Where:
Value2 = number in the desired unit
Value1 = number in the current unit in Aspen Utilities Planner
For example, if current unit for mass flow in Aspen Utilities Planner is
ton/hr and you want to show the number in Mlb/hr, the conversion factor
is 2.21 (Mlb/hr = 2.21 ton/hr).

5 Microsoft Excel Interface

107

108

Run optimization and the results will be populated into the worksheet as
shown here:

5 Microsoft Excel Interface

In addition to the MPResults worksheet, a new worksheet named Costs


is added to the workbook as a result of calling
Application.Run(CostsUpdate)
In the function FlowsheetUpdate.This worksheet lists all the utilities tariff
information as shown below.

Of course, the FlowsheetUpdate function is not limited to calling these two


built-in functions. You can add any tasks you want to run after
optimization inside this function. These tasks could call Excel functions,
other functions you create, or Aspen Utilities functions.

Obtaining Results from Multi-Period


Optimization
After a multi-period optimization has run, the Aspen Utilities Planner Excel
interface retrieves and displays the results for period 1. To obtain the results
for other periods, select Aspen Utilities | Optimization | Get
Optimization Results from the Aspen Utilities menu. A form is displayed
which allows you to enter the period number to retrieve. The simulation is
rerun and results are displayed for that optimization period.

5 Microsoft Excel Interface

109

110

5 Microsoft Excel Interface

6 Aspen Utilities Planner


Reference

Model Library
An Aspen Utilities flowsheet consists of a number of Models.

Models are joined together by Streams.

Streams are connected to the Models by Ports.

In the majority of cases the specification takes place in the models.


Each model has two areas for specifying the equipment. Most of the
specifications for the simulation mode are made in the Summary table
(loaded by double-clicking on the model).
It may also be necessary to provide constraints for equipment used in the
optimization mode. These constraints should be viewed as the physical limits
of a piece of equipment. For example, a boiler has a maximum steam
generation capacity. It also has a minimum turndown which can be translated
into a minimum steam flow if the boiler is in use.
Each model has various limits that can be applied to it in the optimization
mode. These limits are accessed in the Optimization_Limits table. All models
have these optimization limits specified with a default value. You can replace
the default values as required.
During optimization if the model is on (in operation) the constraints set in
the Optimization_Limits table are always obeyed. If a block is off during the
optimization, any minimum constraints are ignored. The only blocks that
cannot be switched off during optimization are Feed and Demand blocks.
It is possible to put optimization limits on streams, however, it is advised not
to do this unless the constraint is associated with the pipe work rather than
equipment.

6 Aspen Utilities Planner Reference

111

List of Models
The following table lists the Aspen Utilities Planner models and their
categories:

112

Model Name

Model Category

Air_Mix

Headers

AirMultiplier

Multipliers

AS_HeatEx

Heat_Exchangers

Boiler

Fuel_Models

Chiller

Heat_Exchangers

Combustor

Fuel_Models

Condenser

Heat_Exchangers

Deaerator

Steam_Models

DemandAir

Demands

DemandFuel

Demands

DemandPower

Demands

DemandSteam

Demands

Desuperheater

Steam_Models

DFBoiler

Fuel_Models

DriveList

Pumps

Dual_Fuel_Demand

Demands

FeedAir

Feeds

FeedFuel

Feeds

FeedPower

Feeds

FeedSteam

Feeds

Fuel_Vap

Heat_Exchangers

FuelHeader

Headers

FuelMultiplier

Multipliers

GasTurbine

Fuel_Models

GeneralModel

Templates

Heater

Heat_Exchangers

Heater_1

Heat_Exchangers

HRSG

Fuel_Models

MultiStageTurbine

Steam_Turbines

PowerHeader

Headers

PowerMultiplier

Multipliers

Pump

Pumps

PumpList

Pumps

SteamEjector

Steam_Models

SteamHeader

Headers

SteamMultiplier

Multipliers

Stm_Flash

Steam_Models

Stm_Mix

Steam_Models

6 Aspen Utilities Planner Reference

Stm_Turb

Steam_Turbines

Stm_Valve

Steam_Models

WW_HeatEx

Heat_Exchangers

AirAirExchanger

Heat_Exchangers

FuelMixer

Fuel_Models

FuelSwitch1toN

Fuel_Models

Burner

Emissions_Model

EmissionsChemney

Emissions_Model

EmissionsNode

Emissions_Model

EmissionsSwitch

Emissions_Model

NOXEstimator

Emissions_Model

General Model Structure

All models have one or more inlet ports and one or more outlet ports. In most
models you can connect multiple streams to one port. In some models only
one stream can be connected to either the inlet or outlet port and where this
is the case it is stated in the model description.
The model has the following general structure:
Inlet Port
(Type 1)

Outlet Port
(Type 1)
Mixer

Splitter

Model Specific
Calculations
Mixer

Splitter

Inlet Port
Outlet Port
Where
not 2)
(Type 2)a port is of a single stream type, the associated splitter or mixer is
(Type
required.

6 Aspen Utilities Planner Reference

113

Variable Naming Convention


The variable naming convention used within a model is as follows:
Portname(PortnameN).Variable Name
Where:
N = number of the port if there are a number of ports of the same type.
For the vast majority of cases N is 1.
Where there are multiple streams connecting to a port the variable naming
convention is:
Portname(PortnameN).Connection(X).Variable Name
Where:
X = name of the stream.

Standard Variable Names in Models

114

Variable

Description

Flow. This is mass flow for all streams except fuel streams
where it is heat flow.

Enthalpy.

Pressure.

Temperature.

vf

Steam vapor fraction.

StartUpCost

Cost of starting up equipment.

ShutDownCost

Cost of shutting down equipment.

StartUpTime

Time to start up equipment.

ShutDownTime

Time to shut down equipment.

DoOnOff

Allow optimizer to switch the unit on/off.

DoStartStop

Startup/Shutdown constraints to be used.

DoSteamReserve

Include steam reserve in optimization.

CI

Carbon Index.

F_mass

Fuel Mass Flow.

F_mol

Fuel Molar Flow.

MW

Molecular Weight.

OD

Stoichiometric Oxygen Demand.

SI

Sulfur Index.

CO2

Carbon Dioxide concentration.

SOx

Oxides of Sulfur concentration.

O2

Oxygen concentration.

Pout

Outlet Pressure (Global model parameter).

Tout

Outlet Temperature (Global model parameter).

DelP

Pressure drop.

Duty

Heat Duty.

Power

Power.

6 Aspen Utilities Planner Reference

Ports and Streams


Four port types have been defined:

Steam Port (also used for water).

Fuel Port.

Power Port.

Air Port.

Four stream types have been defined:

Steam Stream which is used for steam and water streams.

Fuel Stream.

Air Stream used for air and for flue gas.

Power Stream.

Streams can only connect ports of the same type. Therefore a steam stream
can only connect two steam ports. When a stream is dragged onto the
flowsheet only the appropriate ports are highlighted for connection. It is not
possible to connect to the incorrect port type.

Specifying Capacity Limits


Two types of equipment constraints can be specified in Aspen Utilities
Planner; namely equipment design constraints and temporary equipment
constraints. In the optimization, if both constraints are specified for a
particular equipment, then the lower bounds would be determined by the
minimum values whichever is larger, while the upper bound is determined by
the maximum values whichever is smaller.

Equipment Design Constraints


Equipment design constraints should be specified in the Aspen Utilities file
using the Optimization_Limits table associated with each block as shown in
the table below. Care should be taken not to over constrain the problem as
this may results in infeasible solutions.

6 Aspen Utilities Planner Reference

115

Temporary Equipment Constraints


Temporary equipment constraints should be specified in the Availability Profile
for the piece of equipment.

Feeds
Feed blocks are used to represent/define the supply of utilities from outside
the boundary of the utility system model. There are four utility supply blocks
corresponding to the four stream types. Only one stream can be connected to
each feed block.
It is possible to set minimum and maximum flow limits on all feed blocks. It is
not possible to switch off feed blocks during optimization.

FeedSteam

FeedSteam

Description
The FeedSteam model is used to model the external supply of steam or water
to the utility system. This may be purchased steam from an external supplier,
steam generated in a process unit or the supply of make-up water.

116

6 Aspen Utilities Planner Reference

Inlet Ports
There are no inlet ports.

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications
Variable

Description

Tout

Temperature of the steam/water supply.

Pout

Pressure of the steam/water supply.

SteamOut(SteamOut1).F

Flowrate of the steam/water supply.

Note: The flowrate: SteamOut(SteamOut1).F, of the steam feed is a fixed


variable (value must be specified), but may be switched to become a free
variable to satisfy degree of freedom requirements.

FeedFuel

FeedFuel

Description
The FeedFuel model is used to model the external supply of fuel to the utility
system. This steam may be purchased fuel from an external supplier or fuel
generated in a process unit.

Inlet Ports
There are no inlet ports.

6 Aspen Utilities Planner Reference

117

Outlet Ports
Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOut1)

Outlet Stream

No

Specifications
Variable

Description

CVout

Calorific value of the fuel.

MWout

Molecular Weight of the fuel.

OD

Oxygen demand of the fuel.

FuelOut(FuelOut1).F

The heat flow of the fuel.

CI

Optional. Carbon Index.

SI

Optional. Sulfur Index.

Notes:

The oxygen demand of a fuel is the mass ratio oxygen to fuel under
stoichiometric conditions.
The enthalpy flow of the fuel feed: FuelOut(FuelOut1).F, is a fixed
variable by default, but may be switched to become a free variable to
satisfy degree of freedom requirements.
If emissions (CO2 and SOX) are to be calculated within the model then the
Carbon Index (CI) and the Sulphur Index (SI) must be specified. Both of
these indices are the mass ratio of the emission to fuel.

FeedPower

FeedPower

Description
The FeedPower model is used to model the external supply of power to the
utility system. This steam may be purchased power from an external supplier
or power generated in a process unit.

Inlet Ports
There are no inlet ports.

118

6 Aspen Utilities Planner Reference

Outlet Ports
Port Name

Description

Multiple Streams Allowed

PowerOut(PowerOut1)

Outlet Stream

No

Specifications
Variable

Description

PowerOut(PowerOut1).Power

Power Supply.

Note: The power flow: PowerOut(PowerOut1).Power, is specified as fixed


by default, but may be switched to become a free variable to satisfy degree of
freedom requirements.

FeedAir

FeedAir

Description
The FeedAir model is used to model the external supply of air to the utility
system.

Inlet Ports
There are no inlet ports.

Outlet Ports
Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet Stream

No

Specifications
Variable

Description

AirOut(AirOut1).F

Mass flowrate.

Tout

Temperature of the air.

O2

Oxygen content by mass.

Note: The mass flow of the air: AirOut(AirOut1).F, is a fixed variable by


default, but may be switched to become a free variable to satisfy degree of
freedom requirements.

6 Aspen Utilities Planner Reference

119

Demands
Demand blocks are used to represent/define the demand of utilities from
outside the boundary of the utility system model. There are four utility
demand blocks corresponding to the four stream types. Only one stream can
be connected to the demand blocks
It is possible to set minimum and maximum flow limits on all demand blocks.
It is not possible to switch demand blocks off during optimization.

DemandSteam

DemandSteam

Description
The DemandSteam model is used to model demand for steam or water
external to the utility system.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Stream

No

Outlet Ports
There are no outlet ports.

Specifications
Variable

Description

SteamIn(SteamIn1).F

Steam/Water mass flowrate.

Notes:

120

The mass flow of steam, SteamIn(SteamIn1).F, is a fixed variable by


default, but may be switched to become a free variable to satisfy degree
of freedom requirements.
The temperature, pressure, vapor fraction and enthalpy of the steam are
inherited from the outlet of the upstream block. These variables should
never be fixed.

6 Aspen Utilities Planner Reference

DemandFuel

DemandFuel

Description
The DemandFuel model is used to model demand for fuel external to the
utility system.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet Stream

No

Outlet Ports
There are no outlet ports.

Specifications
Variable

Description

FuelIn(FuelIn1).F

Fuel Heat Flow.

Notes:

The enthalpy flow of the fuel: FuelIn(FuelIn1).F, is a fixed variable by


default, but may be switched to become a free variable to satisfy degree
of freedom requirements.
The calorific value, molecular weight, oxygen demand, carbon index and
sulphur index are inherited from the outlet of the upstream block. These
variables should never be fixed.

DemandPower

DemandPower

Description
The DemandPower model is used to model demand for power external to the
utility system.

6 Aspen Utilities Planner Reference

121

Inlet Ports
Port Name

Description

Multiple Streams Allowed

PowerIn(PowerIn1)

Inlet Stream

No

Outlet Ports
There are no outlet ports.

Specifications
Variable

Description

PowerIn(PowerIn1).Power

Power Demand.

Note: The power demand: PowerIn(PowerIn1).Power, is a fixed variable


by default, but may be switched to become a free variable to satisfy degree of
freedom requirements.

DemandAir

DemandAir

Description
The DemandAir model is used to model demand for air external to the utility
system.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet Stream

No

Outlet Ports
There are no outlet ports.

Specifications

122

Variable

Description

AirIn(AirIn1).F

Air mass flowrate.

6 Aspen Utilities Planner Reference

Notes:

The mass flow of the air: AirIn(AirIn1).F, is a fixed variable by


default, but may be switched to become a free variable to satisfy degree
of freedom requirements.
The enthalpy, oxygen, CO2 and SOX content of the air are inherited from
the upstream block. These variables should never be fixed.

Dual_Fuel_Demand

Dual_Fuel_Demand

Description
This block is used to represent a demand for fuel, but where one of two fuels
or a mix of the two fuels can satisfy the demand.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet Stream 1

No

FuelIn(FuelIn2)

Inlet Stream 2

No

Outlet Ports
There are no outlet ports.

Specifications
Variable

Description

FuelIn(FuelIn1).F

Heat Flow of Fuel 1.

FuelIn(FuelIn2).F

Heat Flow of Fuel 2.

Optimization Limits
Variable

Description

MinFuelDuty_1/MaxFuelDuty_1

Minimum/maximum Fuel1 Duty.

MinFuelDuty_2/MaxFuelDuty_2

Minimum/maximum Fuel2 Duty.

Ratio_min/Ratio_max

Minimum/Maximum ratio of Fuel1 to Fuel2


duty.

Note: The calorific value, molecular weight, oxygen demand, carbon index
and sulphur index for each fuel are inherited from the outlet of the upstream
blocks. These variables should never be fixed.

6 Aspen Utilities Planner Reference

123

Headers
There are four headers corresponding to the four stream types.

SteamHeader

Steamheader

Description
The steam header block is used to represent the site steam header systems.
It can also be used to split a steam/water stream. The model allows multiple
feeds and products.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Streams

Yes

Blowsteam(BlowSteam1)

Vent Flow

No

WaterOut(Blowdown)

Blowdown Flow

No

Specifications
Variable

Description

Tout

Nominal Header Temperature.

Pout

Nominal Header Pressure.

BlowSteam(BlowSteam1).F

Vent Steam Flow (Default value is 0).

BDRatio

Blowdown Ratio (Default value is 0).

Optimization Limits

124

Variable

Description

MinFlow/MaxFlow

Minimum and maximum flow of steam/water in


the header.

MinBDFlow/MaxBDFlow

Minimum and maximum blowdown flow.

MinVentFlow/MaxVentFlow

Minimum and maximum vent flow.

6 Aspen Utilities Planner Reference

Note: The heat loss and pressure drop in the header are calculated. The
enthalpy and vapor fraction of outlet are calculated from the temperature and
pressure specification.

FuelHeader

Fuelheader

Description
The fuel header block is used to represent the site fuel distribution system.
The model allows multiple feeds and consumers. The property (MW, OD, CV,
CI, SI) of the fuel within the header is based on an average of the feeds.
These properties are transferred to the outlet streams.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOut1)

Outlet Streams

Yes

Specifications
No specifications required.

Optimization Limits
Variable

Description

MinFuelDuty/MaxFuel Duty

Minimum and maximum total fuel (heating duty) in


the header.

PowerHeader

PowerHeader

Description
The power header block is used to represent the site power distribution
system. The model allows multiple feeds and consumers.

6 Aspen Utilities Planner Reference

125

Inlet Ports
Port Name

Description

Multiple Streams Allowed

PowerIn(PowerIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

PowerOut(PowerOut1)

Outlet Streams

Yes

Specifications
No specifications required.

Optimization Limits
Variable

Description

MinPower/MaxPower

Minimum and maximum total power in the header.

Air_Mix

Air_Mix

Description
The Air_Mix model is used to mix air flows.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet Streams

Yes

Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet Streams

No

Outlet Ports

Specifications
No specifications required.

Optimization Limits

126

Variable

Description

MinFlow/MaxFlow

Minimum and maximum total air flow in the mixer.

6 Aspen Utilities Planner Reference

Steam Models
Deaerator

Description
The deaerator is used for deaeration of water for steam generation. The
deaerator model allows multiple water feeds and a single steam feed. A single
boiler feed water stream is produced. You can also connect a vent stream.
The model calculates the amount of steam required to heat the feed water to
the saturated conditions at the deaerator operating pressure.
Ensure that the water and steam feeds are connected to the correct ports.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Deaeration Steam

No

WaterIn(WaterIn1)

Water Feed

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

WaterOut(WaterOut1)

Water Outlet

No

Blowsteam(BlowSteam1)

Vent Flow

No

Specifications
Variable

Description

Pdeaer

Deaerator operating pressure.

VR

Vent Ratio.

Optimization Limits
Variable

Description

MinBFWout/MaxBFWou
t

Minimum/maximum boiler feed water flow out of the


deaerator.

MinDFWin/MaxDFWin

Minimum/maximum water flow to the deaerator.

MinSteam/MaxSteam

Minimum/maximum steam flow to the deaerator.

MinVent/MaxVent

Minimum/maximum vent flow.

6 Aspen Utilities Planner Reference

127

Note: The vent ratio is specified as follows:


VR = Vent Steam/(Steam Feed- Vent Steam)

Stm_Valve

Stm_valve

Description
This model is used to reduce the pressure of a steam/water stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Stream

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications
Variable

Description

Psout

Outlet Pressure.

Optimization Limits

128

Variable

Description

MinFlow/MaxFlow

Minimum/maximum flow through the valve.

6 Aspen Utilities Planner Reference

Desuperheater

Description
This is used to model letdown stations where the steam is desuperheated.
The amount of water required to desuperheat the steam is calculated.
Ensure that the water and steam feeds are connected to the correct ports.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam

No

WaterIn(WaterIn1)

Desuperheating Water

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications
Variable

Description

Psout

Outlet Pressure.

Tsout

Outlet Temperature.

Optimization Limits
Variable

Description

MinSteam/MaxSteam

Minimum/maximum steam flow.

MinWater/MaxWater

Minimum/maximum water flow.

6 Aspen Utilities Planner Reference

129

Stm_Flash

Description
This is used to model flash drums. The model allows multiple steam streams
at the inlet. The block allows two outlet streams, a water stream, and a steam
stream, both at saturated conditions.
Ensure that the water and steam products are connected to the correct ports.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Flash Steam

No

WaterOut(WaterOut1)

Flash Condensate

No

Specifications
Variable

Description

Pflash

Flash drum operating pressure.

Optimization Limits

130

Variable

Description

MinFeedFlow/MaxFeedFlow

Minimum/maximum total feed flow.

MinVapFlow/MaxVapFlow

Minimum/maximum flash steam flow.

MinLiqFlow/MaxLiqFlow

Minimum/maximum flash condensate flow.

6 Aspen Utilities Planner Reference

Stm_Mix

Description
This model is used to mix steam/water streams. The condition of the outlet
stream is calculated from an energy and mass balance of the feeds.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Flash Steam

No

Specifications
No specifications required.

Optimization Limits
Variable

Description

MinFlow/MaxFlow

Minimum/maximum total flow.

SteamEjector

Description
This model acts as a steam thermocompressor. The outlet steam pressure
and entrainment ratio need to be specified, and the model calculates the inlet
HP and LP steam required.

6 Aspen Utilities Planner Reference

131

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(HPSteamIn)

Inlet Steam

No

SteamIn(LPSteamIn)

Inlet Steam

No

Port Name

Description

Multiple Streams Allowed

SteamOut(IPSteamOut)

Outlet Steam

No

Outlet Ports

Specifications
Variable

Description

EntrainmentRatio

Ratio of LP to HP inlet steam.

Optimization Limits
Variable

Description

MinHPInletSteam/MaxHPInletSteam

Minimum/maximum HP steam flow.

MinLPInletSteam/MaxLPInletSteam

Minimum/maximum LP steam flow.

MinOutletSteam/MaxOutletSteam

Minimum/maximum outlet steam flow.

Pumps
Pump

Description
The pump model is used to increase the pressure of a water stream. The
model allows multiple water feeds and one outlet. One or more power feeds
can also be added to the model.
The pump efficiency can be specified as a fixed value or as an efficiency
curve. The default efficiency method is Constant and in this case, you must
specify the efficiency (ConstEff).

Inlet Ports
Port Name

132

Description

Multiple Streams Allowed

6 Aspen Utilities Planner Reference

SteamIn(SteamIn1)

Inlet Streams

Yes

PowerIn(PowerIn1)

Inlet Power

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications
Variable

Description

Pout

Outlet Pressure.

EffMethod

Efficiency Method (default Constant).

ConstEff

Fixed Efficiency (used if efficiency method is Constant).

NEffPoints

Number of points on the efficiency curve (used is efficiency


method LookUpTable).

If LookUpTable is selected, you must enter the efficiency curve in the EffTable
form. A minimum of two points (NeffPoints) must be specified. The data is
entered as efficiency against volumetric flow through the pump.

6 Aspen Utilities Planner Reference

133

Optimization Limits
Variable

Description

PowerMin/PowerMax

Minimum/maximum power to the pump.

FlowMin/FlowMax

Minimum/maximum mass flow through the pump.

Note: If an efficiency curve is entered for the pump the minimum and
maximum mass flow limits are determined by the range of the efficiency
curve.

Drive List

Description
The drive list model is used to represent a number of motor/turbine drives
that can be used for a particular pump or group of pumps that have the same
service, e.g., cooling tower pumps. The model has both a single steam feed
and steam product, which are connected to each turbine drive in the list. This
means all drives included in the drive list have to be between the same steam
levels. The model also has a single power feed and power product. The power
product stream is connected to a single power demand (a pump or power
demand block).

Inlet Ports

134

Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Streams

No

PowerIn(PowerIn1)

Inlet Power

No

6 Aspen Utilities Planner Reference

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

PowerOut(PowerOut1)

Outlet Power

No

Specifications
Variable

Description

NoDrives

Number of drives being represented 1-n.

DriveName(n)

The name of each drive (Optional).

DriveOption(n)

The type of drive either motor or turbine.

Psout

The outlet pressure of the steam from the turbine drives


(Psout).

Shaftwork(n)

The shaftwork of the drives.

SteamFlow_A(n)

Constant for specifying efficiency of each turbine base


unit ton/hr.

SteamFlow_B(n)

Constant for specifying efficiency of each turbine base


unit ton/hr/MW.

Efficiency(n)

Efficiency of each motor.

Optimization Limits
Variable

Description

MinWork(n)/MaxWork(n)

Minimum/maximum shaftwork produced by a


specific drive.

MinShaftwork/MaxShaftwork

Minimum/maximum shaftwork produced by the


block.

MinFlow/MaxFlow

Minimum/maximum steam flow to the block.

MinPower/MaxPower

Minimum/maximum power flow to the block.

Notes:

The shaftwork should be supplied for n-1 drives. In simulation mode the
shaftwork for the remaining drive is calculated along with the steam
demand of the turbine drives and the power demand for the motor drives.
For each of the turbine drives a set of constants must be supplied to
represent the efficiency of the turbine. The constants can be entered on
the SteamFlow_Constants table. The efficiency of the turbines are
represented as follows:
Steam Demand = SteamFlow_A + SteamFlow_B*Shaftwork
In optimization mode the economic mix of drivers is calculated.

6 Aspen Utilities Planner Reference

135

Pump List

Description
The pump list model represents one or more process pumps which have the
option of either a turbine or motor driver. The model allows only one steam
inlet and one steam outlet stream so pumps should be grouped together by
turbine drivers operating between the same steam levels. The model also
allows a single power feed.
The model does not have a power out port therefore it is not possible to
connect this model to another model on the Aspen Utilities flowsheet as in the
case of the drive list. Instead the power demand is specified directly in the
block for each pair of drives. For optimization, this power demand can be set
in the profiles data editor.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Streams

No

PowerIn(PowerIn1)

Inlet Power

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications

136

Variable

Description

NoPumps

Number of pumps being represented 1-n.

PumpName(n)

The name of each pump (Optional).

PumpOption(n)

The default drive used for the pump.

Psout

The outlet pressure of the steam from the turbine drives.

PowerRequired(n)

The power required for each pump.

SteamFlow_A(n)

Constant for specifying efficiency of each turbine base


unit ton/hr.

SteamFlow_B(n)

Constant for specifying efficiency of each turbine base


unit ton/hr/MW.

Efficiency(n)

Efficiency of each motor.

6 Aspen Utilities Planner Reference

Optimization Limits
Variable

Description

MinFlow/MaxFlow

Minimum/maximum steam flow to the block.

MinPower/MaxPower

Minimum/maximum power flow to the block.

Notes:

For each of the turbine drives a set of constants must be supplied to


represent the efficiency of the turbine. The constants can be entered on
the SteamFlow_Constants table. The efficiency of the turbines are
represented as follows:
Steam Demand = SteamFlow_A + SteamFlow_B*PowerRequired
In optimization mode the economic mix of drivers is calculated.

Turbines
Stm_Turbine

Description
This is used to model a single stage turbine. The isentropic efficiency can be
specified as a fixed value or as an efficiency curve. The default efficiency
method is Constant and you must specify the efficiency (ConstEff).

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Streams

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

PowerOut(PowerOut1)

Outlet Power

No

Specifications
Variable

6 Aspen Utilities Planner Reference

Description

137

Pout

Outlet Pressure.

SteamOut(SteamOut1).F

Flow of steam through the turbine.

EffMethod

Efficiency Method (default Constant).

ConstEff

Fixed Efficiency (used if efficiency method is


Constant).

NEffPoints

Number of points on the efficiency curve (used if


efficiency method LookUpTable).

If LookUpTable is selected then you must enter the efficiency curve in the
EffTable form. A minimum of two points (NeffPoints) must be specified. The
data is entered as flow against power generated in the turbine.

Optimization Limits
Variable

Description

PowerMin/PowerMax

Minimum/maximum power from the turbine.

FlowMin/FlowMax

Minimum/maximum mass flow of steam through the


turbine.

If an efficiency curve is entered for the turbine the minimum and maximum
mass flow limits are determined by the range of the efficiency curve.
Note: The conditions (temperature and pressure) of the steam feed is
supplied by an upstream block. You can change the mass flow of steam
specification to a power specification by fixing variable
PowerOut(PowerOut1).Power or linking it to a power demand on
another block.

138

6 Aspen Utilities Planner Reference

MultiStageTurbine

Description
This is used to model a multiple stage turbine. There are three ways to
specify the performance of multistage turbine: constant isentropic efficiency,
linear relation between power and mass flow and lookup table. The default
efficiency method is Constant and in this case, you must specify the efficiency
(ConstEff).

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(n)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(n)

Outlet Stream

Yes

PowerOut(PowerOut1)

Outlet Power

No

Specifications
Variable

Description

nStages

Number of Stages.

SPout(n)

Outlet Pressure for stages.

SteamIn(n).

Inlet flow of steam through the turbine (includes flow to any


induction stages).

SteamOut(n-1)

Outlet flow of all Extraction stages.

EffMethod

Efficiency Method (default Constant).

ConstEff

Fixed Efficiency (used if efficiency method is Constant).

STout(n-1)

Outlet stage temperature (To be specified if efficiency method


is LookUpTable).

NeffPoints

Number of points on the efficiency curve (used if efficiency


method LookUpTable).

You should specify the type of stages in the stage data form. A multistage
turbine with n stages has n-1 interstages.

6 Aspen Utilities Planner Reference

139

The kInterstange can be used to linearly capture the effect of extraction flow
to nominal power after properly specify the Interstage.

The kInterstage for induction Interstage type is used as:


nominalPower = LooUpTable(Steam Flow) (kInterStage *
ExtractionFlow)

The kInterstage for induction InterStage type is used as:


nominalPower = LookUpTable(Steam Flow) + (kInterStage *
InductionFlow)

The kInterStage for Both Interstage type is used as:


nominalPower = LookUpTable(Steam Flow) + [kInterstage *
(InductionFlow ExtractionFlow)]

For example, when the Interstage is specified as Extraction, the kInterstage


is used to correct the nominal power got from the steam flow by substracting
the product of extraction flow and kInterstage.
If Linear Efficiency method is selected, you must specify the slope and
intercept for the power calculation from steam flow for each stage.

If LookUpTable is selected, you must enter the efficiency curve in the


PerformanceData form. A minimum of two points (nSections) must be
specified. The data is entered as flow against power generated in the turbine.

140

6 Aspen Utilities Planner Reference

Optimization Limits
Variable

Description

MinInlet/MaxInlet

Minimum/Maximum inlet flow to the turbine.

MinimumInduction(n-1)

Minimum induction flow into the stage.

MaximumInduction(n-1)

Maximum induction flow into the stage.

MinimumExtraction(n-1)

Minimum extraction flow from the stage.

MaximumExtraction(n-1)

Maximum extraction flow from the stage.

MinPassout/MaxPassout

Minimum/maximum passout flow from the last


stage.

PowerMin/PowerMax

Minimum/maximum power from the turbine.

sMinFlow(n)/sMaxFlow(n)

Minimum/maximum steam flow through turbine


stage.

ExtrLimitConstant(n-1)

Constant term in extraction flow constraint


equation.

ExtrLimitPowerTerm(n-1)

Power term in extraction flow constraint


equation.

ExtrLimitInletSteamTerm(n-1)

Inlet steam term in extraction flow constraint


equation.

ExtrLimitPassoutTerm(n-1)

Passout steam term in extraction flow constraint


equation.

IndLimitConstant(n-1)

Constant term in induction flow constraint


equation.

IndLimitPowerTerm(n-1)

Power term in induction flow constraint equation.

IndLimitInletSteamTerm(n-1)

Inlet steam term in induction flow constraint


equation.

IndLimitPassoutTerm(n-1)

Passout steam term in induction flow constraint


equation.

If LookUpTable method is selected for the turbine, the minimum and


maximum mass flow limits are determined by the range of the efficiency
curve.

6 Aspen Utilities Planner Reference

141

Notes:

The conditions (temperature and pressure) of the steam feed are supplied
by an upstream block.
You can change the mass flow of steam specification to a power
specification by fixing variable PowerOut(PowerOut1).Power or
linking it to a power demand on another block.

Heat Exchangers
AS_HeatEx

Description
This model is used to model either a steam generator using flue gas or as an
air/steam heat exchanger. You must specify the type of exchanger to be
modeled using HXMode. The options are either HX to model the air/steam
heat exchanger or StmGen to model the steam generator.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

WaterIn(WaterIn1)

Inlet Steam/Water

Yes

AirIn(AirIn1)

Inlet Air/Fluegas

No

Outlet Ports

142

Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

AirOut(AirOut1)

Outlet Air/Fluegas

No

6 Aspen Utilities Planner Reference

Specifications
Variable

Description

HXMode

Heat exchanger type to be modeled.

Tsout

Temperature of the water leaving the exchanger. Required only


for HX mode.

DelPs

Steam side pressure drop.

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

Qmin/Qmax

Minimum/maximum duty.

Tcinmin/Tcinmax

Minimum/maximum temperature of the cold


stream entering the block.

Tcoutmin/Tcoutmax

Minimum/maximum temperature of the cold


stream leaving the block.

Thinmin/Thinmax

Minimum/maximum temperature of the hot


stream entering the block.

Thoutmin/Thoutmax

Minimum/maximum steam flow.

Notes:

In StmGen mode, the duty of the steam generator is calculated assuming


the steam outlet conditions are saturated vapor. The temperature and
enthalpy of outlet air stream is calculated by heat balance. It is assumed
that the flow and conditions of both the air and water streams are
specified in upstream blocks, if not you must also specify these.
In HX mode, you can set the Tsout specification to free and fix either the
duty on the exchanger (Duty) or the temperature of the air leaving the
exchanger (Taout).

Chiller

Description
The air chiller model represents an air cooler using refrigeration. The
refrigeration system is not modeled and the refrigeration system utility
requirements are calculated using factors that relate the chiller duty to the

6 Aspen Utilities Planner Reference

143

steam and power requirements. The temperature of the outlet air stream is
specified. A heat balance is not carried out on the block.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam/Water

No

PowerIn(PowerIn1)

Inlet Power

No

AirIn(AirIn1)

Inlet Air

No

Port Name

Description

Multiple Streams Allowed

WaterOut(WaterOut1)

Steam Condensate

No

AirOut(AirOut1)

Outlet Air

No

Outlet Ports

Specifications
Variable

Description

DelP

Pressure drop on the steam side.

Tsout

The temperature of the steam/water leaving the refrigeration


system.

Taout

The temperature of the air leaving the chiller.

StmFact

The steam factor, which is defined as the mass flow of steam


required per unit of cooling duty. The default units are therefore
ton/GJ.

PowFac

The power factor, which is defined as the power demand per unit
of cooling duty. The default units are therefore MWhr/GJ.

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

Qmin/Qmax

Minimum/maximum duty.

PowerMin/PowerMax

Minimum/maximum power.

Condenser

144

6 Aspen Utilities Planner Reference

Description
This model is used to condense steam. The product stream is saturated water
at the outlet pressure of the condenser.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam/Water

No

FuelIn(FuelIn1)

Inlet Fuel

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

WaterOut(WaterOut1)

Steam Condensate

No

FuelOut(FuelOut1)

Fuel

No

Specifications
Variable

Description

DelP

Pressure drop on the steam side.

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

Qmin/Qmax

Minimum/maximum duty.

FuelVap

Description
This model is used to calculate the amount of steam that is required to
vaporize a liquid fuel stream. It is not a rigorous heat balance, as the
properties of the fuel are not modeled. Instead, you must specify a mass ratio
of steam to fuel required to heat and vaporize the fuel steam.

6 Aspen Utilities Planner Reference

145

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam/Water

No

Port Name

Description

Multiple Streams Allowed

WaterOut(WaterOut1
)

Steam Condensate

No

Outlet Ports

Specifications
Variable

Description

DelP

Pressure drop on the steam side.

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

Qmin/Qmax

Minimum/maximum duty.

MinHFuel/MaxHFuel

Minimum/maximum fuel heat duty.

Heater

Description
This model is used to heat water or steam. It is represented as a single sided
heat exchanger with a single steam feed in and a single steam feed out. The
duty of the heater must be fixed and the data is supplied via the profiles
database.

Inlet Ports

146

Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam/Water

No

6 Aspen Utilities Planner Reference

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Steam/Water

No

Specifications
Variable

Description

DelP

Pressure drop on the steam side.

Duty

Heat exchanger duty.

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

Heater_1

Description
This model is used to heat water or steam. It is represented as a single sided
heat exchanger with multiple steam feeds in and a single steam feed out. The
outlet temperature of the heater must be fixed.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Steam/Water

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Steam/Water

No

Specifications
Variable

Description

DelP

Pressure drop on the steam side.

Tsout

Outlet steam/water temperature.

6 Aspen Utilities Planner Reference

147

Optimization Limits
Variable

Description

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

Qmin/Qmax

Minimum/maximum duty.

WW_HeatEx

WW_HeatEx

The model is used to exchange heat between two water/steam streams. The
model allows multiple water/steam feeds and single product streams. You
must ensure you have connected the feed and product streams to the correct
ports (hot or cold side).

Inlet Ports
Port Name

Description

Multiple Streams Allowed

WaterIn(ColdWaterIn)

Inlet cold water

Yes

WaterIn(HotWaterIn)

Inlet hot water

Yes

Port Name

Description

Multiple Streams Allowed

WaterOut(ColdWaterOut)

Outlet cold water

No

WaterOut(HotWaterIn)

Outlet cold water

No

Outlet Ports

Specifications
Variable

Description

DelPhw

Pressure drop on the hot water side.

DelPcw

Pressure drop on the cold water side.

Thwout

Hot water side outlet temperature.

Optimization Limits

148

Variable

Description

Tcwinmin/Tcwinmax

Minimum/maximum temperature of the cold water


entering the block.

Tcwoutmin/Tcwoutmax

Minimum/maximum temperature of the cold water


leaving the block.

Thwinmin/Thwinmax

Minimum/maximum temperature of the hot water


entering the block.

6 Aspen Utilities Planner Reference

Thwoutmin/Thwoutmax

Minimum/maximum temperature of the hot water


leaving the block.

MinCWFlow/MaxCWFlow

Minimum/maximum hot water flow to the block.

MinHWFlow/MaxHWFlow

Minimum/maximum cold water flow to the block.

Qmin/Qmax

Minimum/maximum duty of the block.

Notes:

The default specification on this block is fixed hot outlet temperature. A


deviation from the default specifications requires changes to be made to
the type of flash being used by the model.
Use of default flash type and any other specification than default causes
the model to not converge or give erroneous results.

Some other common specifications and the changes that are required are
listed below. The changes can be made in the Flash_Type form.

Default - Fixed Hot Outlet Temperature


o

Cold_Outlet.FlashMode

SetPH

Hot_Outlet.FlashMode

SetPT

Fixed Cold Outlet Temperature


o

Cold_Outlet.FlashMode

SetPT

Hot_Outlet.FlashMode

SetPH

Condensing Steam
o

Cold_Outlet.FlashMode

SetPH

Hot_Outlet.FlashMode

SetPV

Fixed Duty
o

Cold_Outlet.FlashMode

SetPH

Hot_Outlet.FlashMode

SetPH

Duty should be a positive number during specification.

6 Aspen Utilities Planner Reference

149

AirAirExchanger

Description
The model is used to exchange heat between two air streams. The model
allows a single air feed in and single outlet stream. You must ensure you have
connected the feed and product streams to the correct ports (hot or cold
side).

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(ColdIn)

Inlet cold air port

No

AirIn(HotIn)

Inlet hot air port

No

Port Name

Description

Multiple Streams Allowed

AirOut(ColdOut)

Outlet cold air port

No

AirOut(HotIn)

Outlet hot air port

No

Outlet Ports

Specifications
Variable

Description

Duty

Heat Duty.

Optimization Limits

150

Variable

Description

MinColdAirFlow/MaxC
oldAirFlow

Minimum/Maximum cold air flow.

MinHotAirFlow/MaxHo
tAirFlow

Minimum/Maximum hot air flow.

TColdAirInMin/TColdAi
rInMax

Minimum/Maximum cold air inlet temperature.

THotAirInMin/THotAirI
nMax

Minimum/Maximum hot air inlet temperature.

TColdAirOutMin/TCold
AirOutMax

Minimum/Maximum cold air outlet temperature.

THotAirOutMin/THotAi
rOutMax

Minimum/Maximum hot air outlet temperature.

6 Aspen Utilities Planner Reference

Qmin/Qmax

Minimum/Maximum heat duty (only used when duty is


specified as fixed variable)

Multipliers
There are four Multipliers corresponding to the four stream types.

SteamMultiplier

Description
The steam multiplier block provides a quick and simple mechanism for
augmenting or decreasing the flowrate of steam in a stream by a fixed factor.
The model supports multiple feed streams but only a single outlet stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOut1)

Outlet Stream

No

Specifications
Variable

Description

Multiplier

Multiplication factor applied to outlet.

Optimization Limits
Variable

Description

MinFlow

Minimum inlet steam flow.

MaxFlow

Maximum outlet steam flow.

Note: There is no heat loss and pressure drop in the block, and all the
properties of the outlet stream are calculated from the mixed inlet stream.

6 Aspen Utilities Planner Reference

151

FuelMultiplier

Description
The fuel multiplier block provides a quick and simple mechanism for
augmenting or decreasing the flowrate of fuel in a stream by a fixed factor.
The model supports multiple feed streams but only a single outlet stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOut1)

Outlet Stream

No

Specifications
Variable

Description

Multiplier

Multiplication factor applied to outlet.

Optimization Limits
Variable

Description

MinFuelDuty

Minimum inlet fuel flow.

MaxFuelDuty

Maximum outlet fuel flow.

Note: All the properties of the outlet stream are calculated from the mixed
inlet stream.set to those of the inlet stream.

PowerMultiplier

152

6 Aspen Utilities Planner Reference

Description
The power multiplier block provides a quick and simple mechanism for
augmenting or decreasing the flowrate of power in a stream by a fixed factor.
The model supports multiple feed streams but only a single outlet stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

PowerIn(PowerIn1)

Inlet Streams

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

PowerOut(PowerOut1)

Outlet Stream

No

Specifications
Variable

Description

Multiplier

Multiplication factor applied to outlet.

Optimization Limits
Variable

Description

MinPower

Minimum inlet power flow.

MaxPower

Maximum outlet power flow.

AirMultiplier

Description
The air multiplier block provides a quick and simple mechanism for
augmenting or decreasing the flowrate of air in a stream by a fixed factor.
The model supports multiple feed streams but only a single outlet stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet Streams

Yes

Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet Stream

No

Outlet Ports

6 Aspen Utilities Planner Reference

153

Specifications
Variable

Description

Multiplier

Multiplication factor applied to outlet.

Optimization Limits
Variable

Description

MinFlow

Minimum inlet air flow.

MaxFlow

Maximum outlet air flow.

Note: There is no heat loss and pressure drop in the block, and all the
properties of the outlet stream are calculated from the mixed inlet stream.

Fuel Models
Boiler

Description
This is a simplified boiler model. A rigorous heat and material balance is
calculated. It is possible to calculate the boiler fan power requirement within
the model and in this case, you can also connect a power feed to the model.
The efficiency can be specified as a fixed value or as an efficiency curve. The
default efficiency method is Constant and in this case you must specify the
efficiency (ConstEff).

154

6 Aspen Utilities Planner Reference

Inlet Ports
Port Name

Description

Multiple Streams Allowed

WaterIn(BFW)

Inlet BFW

Yes

AirIn(AirIn1)

Inlet Air

No

FuelIn(Fuel)

Inlet Fuel

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(VHPSteam)

Steam Production

No

WaterOut(Blowdown)

Blowdown

No

AirOut(Fluegases)

Fuelgas

No

Specifications
Variable

Description

SteamOut(VHPSteam).F

Steam generation rate.

EffMethod

Efficiency method. The default is Constant. The


options are Constant or LookUpTable.

BDRate

Blowdown rate.

O2out

Oxygen content of the fluegas.

Pdrop_Gen

Pressure drop in the steam drum and economizer.

Pdrop_SH

Pressure drop in the superheater.

Tboiler

Temperature of the outlet steam.

FanCoeffB

Coefficients for calculating the boiler fan power


requirement. This is optional.

FanCoeffC

Coefficients for calculating the boiler fan power


requirement. This is optional.

If LookUpTable is selected as the efficiency method, you must enter the


efficiency curve in the EffTable form. A minimum of two points (NeffPoints)
must be specified. The curve is in the form efficiency against steam flow.

Optimization Limits
Variable

Description

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

MinFuelDuty/MaxFuelDuty

Minimum/maximum fuel flow (enthalpy).

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

If an efficiency curve is used then the optimization limits for the


minimum/maximum steam flow are defined as the range of the efficiency
curve.
Note: There is a state parameter defined in the model called
OperationalStatus with possible values of InService and Shutdown.

6 Aspen Utilities Planner Reference

155

This parameter is updated during the flowsheet update after optimization


completes. If the optimization decides the boiler equipment is off and hence
the flows through this equipment are zero, the parameter will be assigned as
Shutdown. As a result, the related equipment design equations are excluded
from the model and related variables are changed to Fixed to keep the model
Square.
This process during the flowsheet update can only work when the default
variable specifications do not change except the
SteamOut(VHPSteam).F.

DF_Boiler

Description
This model is an extension of the boiler model as it allows two fuel feeds.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

WaterIn(BFW)

Inlet BFW

Yes

AirIn(AirIn1)

Inlet Air

No

FuelIn(Fuel1)

Inlet Fuel

No

FuelIn(Fuel2)

Inlet Fuel

No

Outlet Ports

156

Port Name

Description

Multiple Streams Allowed

SteamOut(VHPSteam)

Steam Production

No

WaterOut(Blowdown)

Blowdown

No

AirOut(Fluegases)

Fuelgas

No

6 Aspen Utilities Planner Reference

Specifications
Variable

Description

SteamOut(VHPSteam).F

Steam generation rate.

FuelIn(FuelIn1).F

Heat flow of the first fuel. This can be


interchanged with the flow of the second fuel.

EffMethod

Efficiency method. The default is Constant. The


options are Constant or LookUpTable.

BDRate

Blowdown rate.

O2out

Oxygen content of the fluegas.

Pdrop_Gen

Pressure drop in the steam drum and economizer.

Pdrop_SH

Pressure drop in the superheater.

Tboiler

Temperature of the outlet steam.

FanCoeffB

Coefficients for calculating the boiler fan power


requirement. This is optional.

FanCoeffC

Coefficients for calculating the boiler fan power


requirement. This is optional.

If LookUpTable is selected as the efficiency method, then you must enter the
efficiency curve in the EffTable form. A minimum of two points (NeffPoints)
must be specified. The curve is in the form efficiency against steam flow.

Optimization Limits
Variable

Description

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

MinFuelDuty/MaxFuelDuty

Minimum/maximum fuel flow (enthalpy).

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

If an efficiency curve is used then the optimization limits for the


minimum/maximum steam flow are defined as the range of the efficiency
curve.
Note: As two types of fuel can be used in the dual fuel boiler, one of them
must be specified as Fixed and another must be Free. In order to have
flowsheet updated successfully after the optimization, parameter
BalancingFuel must be specified as the correct fuel stream that are free to
change. Otherwise the flowsheet update will make flowsheet non-square.

Combustor

6 Aspen Utilities Planner Reference

157

Description
This model is used to combust fuel in an air stream and so raises the
temperature of the air stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet Air

No

FuelIn(FuelIn1)

Inlet Fuel

No

Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet Air

No

Outlet Ports

Specifications
Variable

Description

FuelIn(FuelIn1).F

Heat flow of the fuel used in the combustor.

Optimization Limits
Variable

Description

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

MinFuelDuty/MaxFuelDuty

Minimum/maximum fuel flow (enthalpy).

O2min

Minimum O2 in the exhaust.

Gas Turbine

Description
This is a simplified gas turbine model using performance curves. The model
uses lookup tables relating the heat consumption, exhaust flow, and
exhaust temperature to power production. Heat losses are a result of the
model calculations.

158

6 Aspen Utilities Planner Reference

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet Air

No

FuelIn(FuelIn1)

Inlet Fuel

No

SteamIn(SteamIn1)

Inlet Steam

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet Air

No

PowerOut(PowerOut1)

Generated Power

No

Specifications
Variable

Description

Npoints

The number of points that are available on the


performance curves. This can be entered on the
FlowTable or HeatTable forms.

Pow_Vals(n)

The power values against which the


performance curves are entered. Theses are
entered on the Pow_Vals form.

HeatVals(n)

The fuel demand at the various loads on the


HeatTable.

FlowVals(n)

The exhaust flow at the various loads on the


FlowTable.

TempVals(n)

The temperature of the exhaust gas on the


TempTable.

PowerOut(PowerOut1).Power

The power generated by the gas turbine.

ApplyTemperatureCorrection

Binary variable used to choose to apply


temperature correction.

K1Power

Temperature correction factor for power


production (to be specified if temperature
correction is to be used).

K2Power

Temperature correction factor for power


production (to be specified if temperature
correction is to be used).

K1HeatCons

Temperature correction factor for fuel


consumption (to be specified if temperature
correction is to be used).

K2HeatCons

Temperature correction factor for fuel


consumption (to be specified if temperature
correction is to be used).

K1Exhaust

Temperature correction factor for Exhaust flow


(to be specified if temperature correction is to
be used).

K2Exhaust

Temperature correction factor for Exhaust flow


(to be specified if temperature correction is to
be used).

6 Aspen Utilities Planner Reference

159

Variable

Description

K1ExhaustTemp

Temperature correction factor for Exhaust


temperature (to be specified if temperature
correction is to be used).

K2ExhaustTemp

Temperature correction factor for Exhaust


temperature (to be specified if temperature
correction is to be used).

Tref

Reference temperature to be used in


temperature correction factors.

ApplyHumidityCorrection

Binary variable used to choose to apply


humidity correction.

K1Humidity

Humidity correction factor for power production


(to be specified if humidity correction is to be
used).

K2Humidity

Humidity correction factor for power production


(to be specified if humidity correction is to be
used).

AugmentationFactor

Power produced per unit of steam injection.

SteamInjectionPercent

Steam flow as percentage of inlet air.

Optimization Limits
All limits for the optimization are determined from the performance curves.

Gas Turbine Model Input Forms


The gas turbine model requires relatively complicated input compared to
other process models in Aspen Utilities Planner model library and a custom
input form has been created to ease this task.

Access to Model Input Forms.


The gas turbine model input form is displayed by right clicking on the gas
turbine model on the flowsheet and then choosing Form |
PerformanceCorrectionInput from the context menu.

160

6 Aspen Utilities Planner Reference

The input parameters are self-explanatory and consistent with the terms used
in the Specifications table earlier in the previous section.

Specify Humidity and temperature factors


To specify humidity and temperature correction factors, change the value of
ApplyTemperatureCorrection and ApplyHumidityCorrection into True.
New items will appear automatically, and you can input values as required.

6 Aspen Utilities Planner Reference

161

The humidity correction coefficients are at the bottom of the form. The
humidity correction is calculated from these according to:
HumidityCorrection = Humidity*k1 + k2

Input Performance Curves


You can enter three performance curves for the gas turbine:

Exhaust flow vs. Power.

Exhaust temperature vs. Power.

Heat consumption vs. Power.

To specify gas turbine performance curves, right click on the gas turbine and
choose from the Form menu item in the context menu.

Flow Curve
To open the flow curve, right click on the gas turbine and choose Form |
FlowCurve. FlowCurve Profile Plot appears.

162

6 Aspen Utilities Planner Reference

Double click on any part of the diagram (the curve, coordinate, etc.) You can
change the text font, line color, point mark, etc. as you like.
If you want to edit the value of each point or enter additional points, right
click on the gas turbine and choose Form | FlowTable to open the
FlowTable table.

You can edit the value of existing points by changing the Value column.
Change the NPoints to add new points or delete existing points. After entering
the value, the new point will be shown in FlowCurve.

6 Aspen Utilities Planner Reference

163

Heat Curve
To open the heat curve, right click on the gas turbine and choose Form |
HearCurve. HeatCurve Profile Plot appears.

Double click on any part of the diagram (the curve, coordinate, etc.) You can
change the text font, line color, point mark, etc. as you like.
If you want to edit the value of each point or enter additional points, right
click on the gas turbine and choose Form | HeatTable to open the
HeatTable table.

164

6 Aspen Utilities Planner Reference

You can edit the value of existing points by changing the Value column.
Change the NPoints to add new points or delete existing points. After entering
the value, the new point will be shown in HeatCurve.

Temp Curve
To open the temp curve, right click on the gas turbine and choose Form |
TempCurve. TempCurve Profile Plot appears.

Double click on any part of the diagram (the curve, coordinate, etc.) You can
change the text font, line color, point mark, etc. as you like.
If you want to edit the value of each point or enter additional points, right
click the mouse on the gas turbine and choose Form | TempTable to open
the TempTable table.

6 Aspen Utilities Planner Reference

165

You can edit the value of existing points by changing the Value column.
Change the NPoints to add new points or delete existing points. After entering
the value, the new point will be shown in TempCurve.

HRSG

Description
This is a simplified model of a heat recovery steam generator. A rigorous heat
and material balance is calculated. The inlets to the model are a steam
stream for the boiler feed water, air stream and fuel stream for
supplementary firing. The outlets of the model are two steam streams, one
for boiler blowdown and one for steam, and an air stream for flue gas.
The efficiency is specified as the maximum efficiency in the HRSG.

166

6 Aspen Utilities Planner Reference

Inlet Ports
Port Name

Description

Multiple Streams Allowed

WaterIn(BFW)

Inlet BFW

Yes

AirIn(AirIn1)

Inlet Air

No

FuelIn(Fuel)

Inlet Fuel

No

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(VHPSteam)

Steam Production

No

WaterOut(Blowdown)

Blowdown

No

AirOut(Fluegases)

Fuelgas

No

Specifications
Variable

Description

SteamOut(VHPSteam).F

Steam generation rate.

FuelIn(Fuel).F

Heat flow of the first fuel. This can be interchanged


with the flow of the second fuel.

BDRate

Blowdown rate.

O2out

Oxygen content of the fluegas.

Pdrop_Gen

Pressure drop in the steam drum and economizer.

Pdrop_SH

Pressure drop in the superheater.

Tboiler

Temperature of the outlet steam.

Tref

The reference temperature against which efficiency is


defined, i.e. stack temperature at which the efficiency
of the boiler would be 100%.

MaxEff

Maximum efficiency.

Optimization Limits
Variable

Description

MinAirFlow/MaxAirFlow

Minimum/maximum air flow.

MinFuelDuty/MaxFuelDuty

Minimum/maximum fuel flow (enthalpy).

MinStmFlow/MaxStmFlow

Minimum/maximum steam flow.

Note: There is a state parameter defined in the model called


OperationalStatus with possible values of InService and Shutdown.
This parameter is updated during the flowsheet update after optimization
completes. If the optimization decides the HRSG equipment is off and hence
the flows through this equipment are zero, the parameter will be assigned as
Shutdown. As a result, the related equipment design equations are excluded
from the model and related variables are changed to Fixed to keep the model
Square.

6 Aspen Utilities Planner Reference

167

This process during the flowsheet update can only work when the default
variable specifications do not change except the SteamOut(VHPSteam).F.

FuelMixer

Description
This model is used to mix fuel streams.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet fuel stream

Yes

Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOut1)

Outlet fuel stream

no

Outlet Ports

Specifications
No specifications need to be defined in this model.

Optimization Limits
Variable

Description

MinFuelDuty

Minimum inlet fuel flow

MaxFuelDuty

Maximum inlet fuel flow

FuelSwitch1toN

168

6 Aspen Utilities Planner Reference

Description
This model is used to route a fuel stream to an outlet port.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

FuelIn(FuelIn1)

Inlet fuel port

No

Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOutX)

Outlet fuel ports. X


represents the number
of the outlet port.

No

Outlet Ports

Specifications
Variable

Description

nFuelOut

Number of outlet fuel streams

Optimization Limits
Variable

Description

MinimumFuelInletFlow/MaximumFuelInletFlow

Minimum/Maximum flow on the


inlet fuel.

MinimumFlow(FuelOutX)/MaximumFlow(Fuel
OutX)

Minimum/Maximum flow on the


outlet fuel port X.

nMinOutlets/nMaxOutlets

Minimum/Maximum number of
active outlet ports.

Emissions
Burner

Description
The Burner model is used to do the following tasks:

Using multiple fuels, create emission flows based on standard flue-gas


generation (m3/tonne fuel fired).

6 Aspen Utilities Planner Reference

169

Note: The theoretical flue-gas flow is calculated based on factors.


Different factors are available for gas fuels and liquid fuels. These factors
have to be converted in the same units of measure used for the
AirFlowFactors in the burner models.

Model an individual burner, a group of burners, or a duel fuel burner, and


then build the necessary constraints.

Calculate the flue-gas flow and composition. A butner block does not carry
out the thermal calculation. The fuel out of the burner block should be
connected to the fuel block where it is consumed.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamIn1)

Inlet steam

No

FuelIn(FuelInX)

Inlet fuel X
represents the number
of inlet fuel ports
specified by variable
nFuelIn.

Yes

Port Name

Description

Multiple Streams Allowed

FuelOut(FuelOutX)

Outlet fuel ports. X


represents the number
of the outlet port.

No

AirOut(AirOut1)

Outlet air

No

Outlet Ports

170

6 Aspen Utilities Planner Reference

Specifications
Variable

Description

nBurners

Define the number of burners that


exist

nBurnerGroups

Define the number of groups in


which these burners are placed

nBurnerFuels

Specify the number of burners in


which each fuel is used

BurnerFuel

Specify the actual burners in


which the fuel is used

BurnersInGroup

Specify the burners that form part


of each burner group

AtomisationSteamFactor(FuelInletX)

Atomidation steam required per kg


fuel. X represents the number of
the inlet fuel

FuelInletToOutlet(FuelOutletX)

Mapping inlet fuel to outlet fuel


port. X represents the number of
outlet fuel.

AirOut(AirOut1).T

Outlet flue gas temperature

AirDensity

Flue gas density

AirFlowFactor(FuelInX)

Theoretical mass flow (tonner/hr)


of flue gas generation per GJ of
fuel. X represents the number of
inlet fuels

AirOut(AirOut1).O2

Oxygen mass concentration of flue


gas stream.

Optimization Limits
Variable

Description

nMinBurners/nMaxBurners

Minimum/Maximum limits on the


total number of burners that can
be active at a time

nMinGroupBurners/nMaxGroupBurners

Minimum/Maximum limits on the


total number of burners that can
be active in the given burner
group at a time

BurnersInGroup

Specify the burners that form part


of each burner group

6 Aspen Utilities Planner Reference

171

EmissionsChimney

Description
This model is used to combine multiple air/emission streams into a single
stream.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet air streams

Yes

Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet air streams.

No

Outlet Ports

Specifications
No specifications need to be defined in the model.

Optimization Limits
Variable

Description

MinFlow

Minimum total air flow in the


mixer

MaxFlow

Maximum total air flow in the


mixer

EmissionsNode

172

6 Aspen Utilities Planner Reference

Description
This model is used to add constraints on the emission discharges and
concentrations.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet air stream

No

Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Outlet air stream

No

Outlet Ports

Specifications
The following equations are added in order to model and constrain the overall
SOX and CO2 emission in the tracking period:

TotalSOX = PastSOXProd + RemainingTime * SOXFlow

TotalCO2 = PastCO2Prod + RemainingTime * CO2Flow

EndOfPeriodCO2conc = TotalCO2 / TotalFlueVol

EndOfPeriodSOXconc = TotalSOX / TotalFlueVol

Variable

Description

PastSOXProd

Previous SOX production, kg

PastCO2Prod

Previous CO2 production, kg

RemainingTime

Time span of the current


optimization period, hr

Optimization Limits
Variable

Description

MinAirFlow/MaxAirFlow

Minimum/Maximum total air flow


from the block

MinSOXFlow/MaxSOXFlow

Minimum/Maximum SOX flow in


the current optimization period

MinCO2Flow/MaxCO2Flow

Minimum/Maximum CO2 flow in


the current optimization period

MinSOXConc/MaxSOXConc

Minimum/Maximum SOX
concentration

MinCO2Conc/MaxCO2Conc

Minimum/Maximum CO2
concentration

MinEndOfPeriodSOX/MaxEndOfPeriodSOX

Minimum/Maximum SOX flow at


the end of tracking period

MinEndOfPeriodCO2/MaxEndOfPeriodCO2

Minimum/Maximum CO2 flow at


the end of tracking period

MinEndOfPeriodSOXConc/MaxEndOfPeriodSOX
Conc

Minimum/Maximum SOX
concentration at the end of
tracking period

6 Aspen Utilities Planner Reference

173

Variable

Description

MinEndOfPeriodCO2Conc/MaxEndOfPeriodCO2
Conc

Minimum/Maximum CO2
concentration at the end of
tacking period

MinTotalFlueGas/MaxTotalFlueGas

Minimum/Maximum volumetric
flow of flue gas

EmissionsSwitch

Description
This model is used to route an emission stream to an outlet subject to the
SOX and CO2 flow and concentration limits specified for the ports.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Inlet air

No

Port Name

Description

Multiple Streams Allowed

AirOut(AirOutX)

Outlet air, X represents


the number of outlet
air ports

No

Outlet Ports

Specifications
Variable

Description

nAirOut

Specify the number of outlet air


ports

Optimization Limits

174

Variable

Description

MinInletAirFlow/MaxInletAirFlow

Minimum/Maximum inlet air flow

MinAirFlowOut(AirOutX)/MaxAirFlowOut(Air
OutX)

Minimum/Maximum outlet air flow


on the outlet port X

MinSOXInletFlow/MaxSOXInletFlow

Minimum/Maximum inlet SOX flow

MinSOXInletConc/MaxSOXInletConc

Minimum/Maximum inlet SOX


concentration

MinCO2InletFlow/MaxCO2InletFlow

Minimum/Maximum inlet CO2 flow

MinCO2Conc/MaxCO2Conc

Minimum/Maximum inlet CO2

6 Aspen Utilities Planner Reference

Variable

Description
concentration

MinSOXOutConc(AirOutX)/MaxSOXOutConc(
AirOutX)

Minimum/Maximum outlet SOX


concentration on outlet air port X

MinCO2OutConc(AirOutX)/MaxCO2OutConc(
AirOutX)

Minimum/Maximum outlet CO2


concentration on outlet air port X

NOXEstimator

Description
NOXEstimator is used as a general block to model NOX generation processes
such as Boiler, HRSG, Gas Turbine, etc. The model is typically used to handle
nonlinear NOX generation curve by piecewise linearization.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

AirIn(AirIn1)

Air inlet port

Yes

SteamIn(SteamIn1)

Steam inlet port

Yes

FuelIn(FuelIn1)

Fuel inlet port

Yes

PowerIn(PowerIn1)

Power inlet port

Yes

WaterIn(WaterIn1)

Water inlet port

Yes

Outlet Ports
Port Name

Description

Multiple Streams Allowed

AirOut(AirOut1)

Air outlet port

No

SteamOut(SteamOut1)

Steam outlet port

No

FuelOut(FuelOut1)

Fuel outlet port

No

PowerOut(PowerOut1)

Power outlet port

No

WaterOut(WaterOut1)

Water outlet port

No

6 Aspen Utilities Planner Reference

175

Specifications
Variable

Description

nAirIn

Number of air inlet ports

nSteamIn

Number of steam inlet ports

nPowerIn

Number of power inlet ports

nFuelIn

Number of fuel inlet ports

nWaterIn

Number of water inlet ports

nAirOut

Number of air outlet ports

nSteamOut

Number of steam outlet ports

nPowerOut

Number of power outlet ports

nFuelOut

Number of fuel outlet ports

nWaterOut

Number of water outlet ports

nPoints

Number of points in the NOX


generation

NOXCorrVars

Boolean indicator of additional


correction variables on the NOX
generation

nNOXCorrVars

Number of correction variables

NOXCorrectionVariables(*)

The port name related to the


correction variables

NOXGenCorr_A(*)

Parameter A in the correction for


the corresponding correction
variable

NOXGenCorr_B(*)

Parameter B in the correction for


the corresponding correction
variable

Notes:
The above parameters for specifying the number of inlet and outlet ports
have a maximum limit of 1 and minimum limit of 0. This indicates these
parameters behave more like Boolean indicators of whether the block has
the particular type of ports (1 = Yes, 0 = No).
In the Emissions table, you must specify nPoints and then enter the NOX
generation curve in terms of Fuel consumption vs. NOX generation.
If the NOX generation curve also involves other variables, they can be
included by specifying the correction variables. For example, if the NOX
generation curve can be expressed as an nonlinear function of fuel
NOXCorrectionVariables(1) should be SteamOut1.
NOX = f (Fuel) + A*Steam + B
This block is typically inserted in front of a fuel consumption block such as
Boiler, GT, HRSG, etc. The inlet fuel is first fed to the NOX Estimator and
then passes through to the fuel consumption block. In the NOXEstimator
block, at least an inlet fuel port and an outlet air port must be specified.
Other ports can be added depending on the correction terms.
NOXGen, NOXGen_Fuel and NOXGen_TotalCorr are the variables that
store the results of NOX generated in the progress.

176

6 Aspen Utilities Planner Reference

Optimization Limits
There are no optimization limits for this model.

Templates
General Model

Description
This is a general model, which has all the types of ports at the inlet and at the
outlet. You can specify the number of ports for each type in the Summary
form.

Inlet Ports
Port Name

Description

Multiple Streams Allowed

SteamIn(SteamInn)

Steams Port 1 to n

Yes

AirIn(AirInn)

Air Ports 1 to n

Yes

FuelIn(FuelInn)

Fuel Ports 1 to n

Yes

PowerIn(PowerInn)

Power Ports 1 to n

Yes

WaterIn(WaterInn)

Water Ports 1 to n

Yes

6 Aspen Utilities Planner Reference

177

Outlet Ports
Port Name

Description

Multiple Streams Allowed

SteamOut(SteamOutn)

Steams Port 1 to n

No

AirOut(AirOutn)

Air Ports 1 to n

No

FuelOut(FuelOutn)

Fuel Ports 1 to n

No

PowerOut(PowerOutn)

Power Ports 1 to n

No

WaterOut(WaterOutn)

Water Ports 1 to n

No

Specifications
Variable

Description

SteamOut(SteamOutn).F

Steam Mass Flow

SteamOut(SteamOutn).T

Steam Temperature

SteamOut(SteamOutn).P

Steam Pressure

FuelOut(FuelOutn).F

Fuel Heat Flow

FuelOut(FuelOutn).OD

Fuel Oxygen Demand

FuelOut(FuelOutn).CV

Fuel Calorific Value

FuelOut(FuelOutn).MW

Fuel Molecular Weight

WaterOut(WaterOutn).F

Water Mass Flow

WaterOut(WaterOutn).T

Water Temperature

WaterOut(WaterOutn).P

Water Pressure

AirOut(AirOutn).F

Air Mass Flow

AirOut(AirOutn).O2

Air O2 Content

AirOut(AirOutn).SOx

Air SOx Content

AirOut(AirOutn).T

Air Temperature

AirOut(AirOutn).CO2

Air CO2 Content

PowerOut(PowerOutn).Power

Power Flow

SteamIn(SteamInn).F

Steam Mass Flow

FuelIn(FuelInn).F

Fuel Heat Flow

WaterIn(WaterInn).F

Water Mass Flow

AirIn(AirInn).F

Air Mass Flow

PowerIn(PowerInn).Power

Power Flow

In all cases n refers to the port number.

Optimization Limits
There are no optimization limits for this model.

178

6 Aspen Utilities Planner Reference

Flowsheet Development
Dealing with Snapshots
A Snapshot is a binary data file that stores all the variable values in the
simulation. The snapshot files are generated by Aspen Utilities Planner/Aspen
Custom Modeler according to the snapshot settings in Tools | Settings.
Please refer to the Aspen Custom Modeler User Guide to learn more about
snapshots (search for Snapshot).

Variable Specification Fixed and Free


Since Aspen Utilities Planner is derived from Aspen Custom Modeler, all
utilities models are written in the Equation Oriented (EO) form. All variables
declared in models have three specifications by default: Fixed, Free, and
Initial. The Initial specification is used by dynamic simulation and ignored in
Aspen Utilities Planner.
When a variable is specified as Fixed, it is an input value, and the value will
not be changed during the simulation. If a variable is declared as Free, it is an
output variable, and its value will be determined by the equation calculations.
The value is updated when the simulation or optimization is complete.
All equations are solved simultaneously in the static-state EO model by an
algebraic algorithm (e.g., Newton-Raphason method). In order to solve the
model, the flowsheet must be square, i.e., the number of equations defined
in the model must be equal to the number of Free variables.
To learn more about variable specification, please refer to the Aspen Custom
Modeler User Guide.

6 Aspen Utilities Planner Reference

179

180

6 Aspen Utilities Planner Reference

Appendix 1 Configuring the


Demand Forecasting Editor

The demand forecasting application uses a subset of tables within the demand
database which need to be configured following a certain convention. The
structure and relationships between these tables is shown in the diagram
below:

Structure of the Demand Forecasting Module

The demand forecasting application calculates a number of utility demands


(known as DemandCalcs or DemandVars within the database) from general
equations that contain production parameters and operation modes. These
DemandCalcs are linked to appropriate block ports within the Aspen Utilities
Flowsheet via a mapping in the Profiles Database.

Appendix 1 Configuring the Demand Forecasting Editor

181

In earlier versions the equations were of the form:


y = f(x)
where:
y = the utility demand
x = production parameter
and five equation functions were supported:

Fixed (y = A)

Linear (y = Bx+A)

Quadratic (y = Cx2+Bx+A)

Power (y=DxE)

Exponential (y=GeFx)

You selected the equation type and entered the equation coefficients.
The new equations are much more general and flexible. Because DFE uses
Microsoft Excel to evaluate the equations, the equations can contain any
operation that can be used in Excel.
This version of the Demand Forecasting is configured slightly differently than
11.1 to support the use of multiple cases within the profiles editor. It will
however read databases configured for the 11.1 editor.
To distinguish between various configurations of Demand Database there is a
version field in the VersionInfo table of the Demand Database.
The possible values are:

1.0.0.1 Describes an 11.1 database without any support for modes.

2.0.0.1 Describes an 11.1 database with support for modes.

2.0.0.2 Describes a database configured to be compatible with multiple


Cases.

The following steps are required to configure the Demand Forecasting


module.
1

182

Configuring the demand profile and period set ID the data is saved to.
This is achieved by configuring the data within the following tables:
o

PeriodSet

Period

GeneralInput

Config

Configuring the data about the production parameters. This is achieved by


configuring the following tables:
o

DemandForecastingInput

XinVal

Appendix 1 Configuring the Demand Forecasting Editor

Configuring the various modes of operation for each unit if applicable.


This is achieved by configuring the following tables:
o

TblModeValues

TblModes

PeriodModes

Configuring the individual equations that make up the CalcVars. This is


achieved by configuring the CalcVars table.

Configuring the link between CalcVars and the variables within the Aspen
Utilities Model. This is achieved by configuring the DemandCalcs table.

Before you Start


The easiest way of configuring the demand forecasting application is to
configure each table in turn in the order shown above. Before starting to
configure the demand database the demand profiles within the profiles
database should already have been configured using the Profile data editor.
We will use the example file that comes with the Aspen Utilities Planner
Installation (example.auf) to show how to configure Demand Forecasting.
Note: This example does not refer to the example databases in the Aspen
Utilities installation.

Example Aspen Utilities Flowsheet

Demands need to be calculated for five demand blocks:

SteamFeed

Appendix 1 Configuring the Demand Forecasting Editor

183

HPUSE

LPGEN

LPUSE

PWRUSE

There are three process units on the site (Acetic Acid, VAM and EtAc) each of
which takes a different mix of utilities. The individual utility demands for each
of the process units need to be calculated, summed and linked to the correct
demand block.
The table below shows which unit uses/generates which utility and the
equation that links the utility demand to the production parameter. All of the
production rates are in ton/hr.
Unit

Process

Equation

HP Generation

Acetic Acid Process

Mode 1:

(ton/hr)

0.4* Acetic Acid production rate + 2


Mode 2:
2.3 * Acetic Acid production rate

HP Use

VAM Process

1.2* VAM production rate + 1

(ton/hr)

EtAc Process

0.03* (EtAc production rate)2 +0.4*


EtAc production rate

LP Generation

EtAc Process

1.7* EtAc production rate + 3.8

Acetic Acid Process

Mode 1:

(ton/hr)
LP Use
(ton/hr)

1.02* Acetic Acid production rate


Mode 2:
23
VAM Process

3e(VAM production rate*0.06)

Power Use

Acetic Acid Process

9.5

(MWh)

VAM Process

EtAc Process
Demand Forecasting Correlations

3.2
0.27* EtAc production rate

The equation coefficients should be such that the y value is calculated in the
Aspen Utilities Planner base units of measurement.
Units of measurement for the x parameter can be chosen. When the demand
forecasting application is also used for performance monitoring, the equations
should be set up so that the x parameter is in the same units of measure as
any corresponding IMS tag which measures that parameter.

184

Appendix 1 Configuring the Demand Forecasting Editor

The Profiles database should already have been generated and the Demand
Variable Map is shown below:
ID

DemandProfileId

EquipmentPropId

HPUSE.D1

D1

HPUSE.SteamIn1

LPGEN.D1

D1

LPGEN.SteamOut11

LPUSE.D1

D1

LPUSE.SteamIn1

PWRUSE.D1

D1

PWRUSE.PowerIn1

SteamFeed.D1

D1

SteamFeed.SteamOut
1

IP21SourceTag

Configured tblDemandVarMap

Units of Measure
All utility demands should be calculated in the Aspen Utilities Planner base
units of measure.
These are:

For steam/water flows ton/hr.

For power flows MW.

For fuel flows GJ/hr.

For air flows, ton/hr.

The units of measure for each of the production parameters needs to be


consistent within Demand forecasting, for example all correlations which use
VAM production rate need to have the VAM production rate in the same units
of measure. However, the units of measure for production parameters can be
mixed, e.g., VAM production rate can be entered in ton/hr and EtAc
production rate can be entered in kg/hr.
If Demand forecasting is used on-line for utility target calculations, the unit of
measure for each of the production parameters should be the same as the
unit of measure for that parameter within the IMS.

Configuring General
Information
EquationTypes
This table lists all of the equation types that are used within Demand
forecasting.
Important: Do not edit this table.

Appendix 1 Configuring the Demand Forecasting Editor

185

Operators
This table lists the operators used within the demand forecasting module.
Important: Do not edit this table.

Config
This table is used to set the number of decimal places that are used to display
the results of the calculation.

PeriodSet
There are three fields for each record:
Field

Description

PeriodSetID

This is the ID of the period set that the data is saved to. The
period set ID must be the same as the period set ID used to define
the default case within the profiles database. This is usually P1.

NoOfPeriods

This is the number of periods within the profile. When setting up


the database this can be entered as 1 and then can be increased
when the data base configuration is complete and the editor can
be used.

StartTime

This is the starting time for the first period. Again any date/time
can be entered here as it can be altered using the editor. The
format for the data/time is dd/mm/yyyy hh:mm:ss.

PeriodSetID

NoOfPeriods

P1
1
Completed PeriodSet Table

StartTime
07/05/2002 00:00:01

Note: If your database has a version number of 2.0.0.2, the PeriodSetID field
is not used to determine the periodset written to in the profiles database,
instead the PeriodSetID as defined by the Case (from tblCases in the Profiles
Database) is used.

Period
There are four fields in the Period table:

186

Field

Description

PeriodID

A unique ID for the period, used when specifying the values of the
production parameters. When periods are added to the demand
forecasting database, the PeriodIDs are generated automatically
and are of the form Period1, Period2 etc. It is therefore
recommended but not necessary to use Period1 as the ID for the
first period.

PeriodNo

This is the order number of the period, i.e., period 1 has the
PeriodNo 1, period 2 has the PeriodNo 2 and so on.

Appendix 1 Configuring the Demand Forecasting Editor

Field

Description

PeriodLength

This is the length of the period in hours. Any number can be


entered here as it can be changed within the editor.

PeriodSetID

This is the period set that has been set in the PeriodSet Table.

PeriodID

PeriodNo

Period1
1
Completed Period Table

PeriodLength

PeriodSetID

P1

GeneralInput
There are three fields in the GeneralInput table:
Field

Description

DemandProfileID

The ID of the demand profile the data is saved to. In the first
instance you cannot change the profile the data is saved as
because the profiles editor does not support multiple profiles.
The ID selected must be the same ID and the default demand
profile ID used in the profiles database. This is usually D1.

PeriodSetID

This is the ID of the period set the period data is saved to. As
with the demand profile ID, you cannot change this
information and the selected ID must be the same as the
default period set ID used in the profiles database. This is
usually P1.

DefaultCase

This field is not used.

For our example the completed table looks like this:


DemandProfileID

PeriodSetID

D1
PS1
Completed GeneralInput Table

DefaultCase
1

Note: If your database has a version number of 2.0.0.2 then the


DemandProfileID field and PeriodSetID field are not used. These values are
taken from the Current case (and are defined in tblCases of the Profiles
Database).

Configuring Production
Parameters
DemandForecasting
Input
This table is used to list all of the production parameters used in demand
forecasting equations:

Appendix 1 Configuring the Demand Forecasting Editor

187

Field

Description

ID

A short ID for the production parameter used internally within the


database. It should be descriptive enough for you to configure the
database but not too long. For example, one of our production
parameters is VAM production so the ID could be VAMProd.

Legend

The legend for the production parameter. This legend is displayed


within the editor and therefore should provide sufficient
information to the reader. It is also useful to include the unit of
measure for the production parameter. For our example, the
legend could be VAM Production Rate, ton/hr

TagID

This field is not used.

DefaultXVal

The default value for the production parameter used if the number
of periods used for demand generation is increased. These data
can be altered using the editor.

In our example, we have the following production parameters:

Acetic Acid Production Rate

VAM Production Rate

EtAc Production Rate

All of these production rates are in ton/hr.


For our example, the completed table is as follows:
ID

Legend

TagID

AAProd

Acetic Acid Production Rate,


ton/hr

VAMProd

VAM Production Rate, ton/hr

EtAcProd
EtAc Production Rate, ton/hr
Completed DemandForecastingInput Table

188

DefaultXVal
25
31
27

Appendix 1 Configuring the Demand Forecasting Editor

XinVal
This table is used to specify the value of the production parameters. Some
data needs to be entered into the table initially but this data can then be
edited using the editor:
Field

Description

ID

A unique ID consisting of a concatenation of the


DemandForecastingID and the Period Number. This must
be typed into the database initially but is automatically
generated when further periods are added to the demand
forecast.

DFID

The DemandForecastingID for the production parameter


and is selected from a drop-down box

DemandProfileID

The demand profile ID associated with the values. This is


selected from the drop-down box

PeriodID

The period that the production parameter is being set for.


This is always likely to be period 1 as it is unlikely the
database would initially be set up for more than one
period.

This is the value for the particular production parameter


for the particular period.

ID

DFID

DemandProfileID

PeriodID

AAProd.1

AAProd

D1

Period1

23

EtAcProd.1

EtAcProd

D1

Period1

28

D1

Period1

30

VAMProd.1
VAMProd
Completed XinVal Table

Appendix 1 Configuring the Demand Forecasting Editor

189

Configuring Modes
TblModes
This table is used to provide information on which plants have modes. The
table consists of the following fields:
Field

Description

Mode_ID

This ID is used to link the mode to the Plant.

Legend

The legend viewed through the demand forecasting editor.

Description

This field provides a more detailed description. This is not viewed


through the editor.

DefaultValue

The default mode used if additional periods are added to the


profile. This is used to initialize the program and the value can be
changed.

Mode_ID

Legend

Description

DefaultValue

ACETIC

Acetic Acid Plant


Mode

Correlation adjuster for


Acetic values

ACETIC.LEAN

EO

EO Mode

Correlation Adjuster for


EO values

EO.MEDIUM

SEASON

Season

Seasonal adjuster for


correlations

SEASON.WINTER

Completed tblModes Table

190

Appendix 1 Configuring the Demand Forecasting Editor

TblModeValues
This table is used to list all of the available modes for each of the process
units. The table consists of the following fields:
Field

Description

ID

A unique ID for each mode the plant can operate it. The
convention is to concatenate the Mode_ID with the mode ordinal
value.

Mode_ID

The Mode_ID as described in the previous table.

ValueString

Description of the mode.

OrdinalValue

An integer value for the mode. This must be unique within a


Mode_ID.

ID

Mode_ID

ValueString

OrdinalValue

ACETIC.LEAN

ACETIC

Lean

ACETIC.RICH

ACETIC

Rich

EO.HIGH

EO

High

EO.LOW

EO

Low

EO.MEDIUM

EO

Medium

SEASON.FALL

SEASON

Fall

SEASON.SPRING

SEASON

Spring

SEASON.SUMMER

SEASON

Summer

Winter

SEASON.WINTER
SEASON
Completed tblModeValues Table

PeriodModes
This table is used to store the mode setting for each period in the profile. The
table consists of the following fields:
Field

Description

PeriodMode_ID

A concatenation of PeriodID and Mode_ID to make a unique


identifier.

Period_ID

The ID of the period in question.

Mode_ID

The Mode_ID as described in the previous table.

ModeValueID

ID (from tblModeValues) of the mode to be used in that period.

PeriodMode_ID

Period_ID

Mode_ID

ModeValueID

Period1.ACETIC

Period1

ACETIC

ACETIC.LEAN

SEASON

SEASON.FALL

Period1.SEASON
Period1
Completed PeriodModes Table

Appendix 1 Configuring the Demand Forecasting Editor

191

Configuring Calculations
Refer to the CalcVars section if you need to reference earlier versions of the
Demand database.

tblEquationDefinition
This table specifies the equations used for calculating the utility demands
from production parameters and modes of operation.
The table consists of the following fields:
Field

Description

recID

An ID created automatically by Microsoft Access.

EqnID

The equation ID referenced by DemandVarEquationID in the


DemandCalcsEquations table

EqnDescription

A description of the utility demand being calculated by the


equation. The description is displayed in Equation Editor.

EqnString

Description of each equation.

In our example, if the production rate is zero, the utility demands should be
zero also. Therefore we need to put a conditional (IF statement) around the
equation.
The completed table might be:
recID

EqnID

EqnDescription

EqnString

cvY1

Reboiler Steam

IF("[SEASON]"="(SEASON.WINTER)",
IF([X1]>0,6+0.2*[X1]+2*[X1]^2,0),90)

cvY10

CT2 Turbines Y10

IF("[EO]"="(EO.MEDIUM)",5,0)

cvY11

CT2 Turbines Y11

IF("[EO]"="(EO.LOW)",0,0)

cvY12

CT2 Turbines Y1

IF("[SEASON]"="(SEASON.FALL)",1,0)

cvY13

CT2 Turbines Y13

IF("[SEASON]"="(SEASON.SUMMER)",3,0
)

cvY14

CT2 Turbines Y14

IF("[SEASON]"="(SEASON.WINTER)",4,0)

cvY2

Stripping Steam

IF("[ACETIC]"="(ACETIC.LEAN)",0,0)

cvY3

Turbine PT5

cvY4

CT1 Turbines

15

10

cvY5

CT2 Turbines Y5

0.5*[X1]^1.5 + 37.71

11

cvY6

CT2 Turbines Y6

IF("[ACETIC]"="(ACETIC.RICH)",1000,0)

12

cvY7

CT2 Turbines Y7

IF("[SEASON]"="(SEASON.SPRING)",2,0)

13

cvY8

CT2 Turbines Y8

IF("[EO]"="(EO.HIGH)",10,0)

14

cvY9

CT2 Turbines Y9

IF("[ACETIC]"="(ACETIC.LEAN)",0.5,0)

15

HPUSE.St
eamIn1

Total
HPUSE.SteamIn1

+[cvY1] +[cvY2]

16

LPGEN.St
eamOut1

Total
LPGEN.SteamOut
1

+[cvY4] +[cvY3]

192

Appendix 1 Configuring the Demand Forecasting Editor

CalcVars
This CalcVars section, while obsolete, is included in case you need to
reference earlier versions of the Demand database. Refer to the
tblEquationDefinition section for a description of the current database.
This table specifies the equations used for calculating the utility demands
from the production parameters.
The table consists of the following fields:
Field

Description

DemandForecastingInputID

The ID of the production parameter used to


calculate the utility demand. This ID is selected
from a drop-down box.

YvalID

This field is not used.

CalcVarID

A short but descriptive ID for the utility demand


that is being calculated. This ID must be unique.
In our example, we calculate the HP use on the
EtAc plant. Therefore the CalcVarID could be
EtAcHPUse.

Legend

A longer description of the utility demand being


calculated. This is the description displayed.
Therefore for our example, the legend may be
EtAc HP Steam Use, ton/hr.

EquType

The type of equation used to calculate the utility


demand. This is selected from a drop-down list.

TagID

This field is not used.

CoeffA - CoeffG

These are the coefficient for the demand


generation equation. Use the convention shown in
section A1.

IsZeroNotZero

A flag used to ignore any fixed consumptions if the


production rate is zero, i.e., if an equation is of the
form 2 * production rate +3, if the production rate
is zero the equation still yields a demand of 3. If
the utility demand of the unit is zero when the unit
is shut down then this field should be ticked off.

Mode

The particular mode for which this calculation is


applicable. This is the ID from tblModeValues. If
there are no modes then the value NONE.ALL
should be entered.

ModeID

This is the mode_ID from tblModes.

In our example, if the production rate is zero, the utility demands should be
zero as well. Therefore, the IsZeroNotZero flag must be set if there are any
fixed consumptions. Also the power usage correlations on Acetic Acid and
VAM are not a function of production rate but they need to be linked to
production rate to enable the flag to work.

Appendix 1 Configuring the Demand Forecasting Editor

193

For the example, the completed table is shown in the following table:

Completed CalcVars Table

194

Appendix 1 Configuring the Demand Forecasting Editor

Configuring Demand
Calculations
Refer to the DemandCalcs section if you need to reference earlier versions of
the Demand database.

DemandCalcsEquations
This table is used to relate a Demand variable to the equation that calculates
the demand.
The DemandVarID along with tblDemandVarMap in the Profiles database link
the total utility demand to a variable in the Aspen Utilities flowsheet.
The table consists of the following fields:
Field

Description

DemandVarID

This field maps a demand to an Equipment Property in


the Profiles database to one equation in
tblEquationDefinition. The name of this field is a legacy
from 11.1.
This field should contain the EquipmentPropId defined for
the Demand in question from the tblDemandVarMap
table in the profiles database

DemandVarEquationID

The ID of the equation that calculates the demand for


DemandVarID

For our example the completed table looks like this:


DemandVarID

DemandVarEquationID

HPUSE.SteamIn1

HPUSE.SteamIn1

LPGEN.SteamOut1

LPGEN.SteamOut1

PWRUSE.PowerIn1

PWRUSE.PowerIn1

SteamFeed.SteamOut1
SteamFeed.SteamOut1
Configured DemandCalcsEquations Table

DemandCalcs
This DemandCalcs section, while obsolete, is included in case you need to
reference earlier versions of the Demand database. Refer to the
DemandCalcsEquations section for a description of the current database.
This table is used to add all of the individual CalcVars together and link them
to a DemandVarID, which through the profiles database, links the total utility
demand to a variable in the Aspen Utilities flowsheet.
The table consists of the following fields:
Field

Description

DemandVarID

This field maps a demand to an Equipment Property in the Profiles


database to one or more calculations the results of which are
combined to produce the overall demand. The name of this field is

Appendix 1 Configuring the Demand Forecasting Editor

195

Field

Description
a legacy from 11.1.
This field should contain the EquipmentPropId defined for the
Demand in question from the tblDemandVarMap table in the
profiles database.

CalcVarID

The calculated utility demand that is part of that particular overall


utility demand. This is selected from a drop-down box.

Operator

An operator which shows the relationship of that particular utility


demand (CalcVar) to the overall demand (i.e., is added to the
overall demand or taken away).

In our example, we have a single block representing HP Use and the


DemandVarID defined for this in the Profiles database is HPUSE.D1.
Therefore, we enter the EquipmentPropId value for that record in the Profiles
database which is HPUSE.SteamIn1
However, two plants take HP steam: VAM and EtAc. The two demands must
be added together to give the total HP Demand. Therefore, in the table we
must add a record with the DemandVarID of HPUSE.SteamIn1, select the
CalcVar associated with HP Steam demand in VAM (VAMHPUse) and then
select the operator +, since this demand is being added to the overall
demand.
A second record is then added to the table, again with the DemandVarID of
HPUSE.SteamIn1 but this time select the CalcVar associated with HP Steam
use in EtAc (EtAcHPUse). Again, the operator to use is +.
Where there are specific calculations for modes all of the calculations should
be included (as shown for SteamFeed.SteamOut1) below. The executable
determines which equations should be switched on depending upon the
particulate mode selected by the user.
For our example the completed table looks like this:

196

DemandVarID

CalcVarID

Operator

SteamFeed.D1

AAHPGenMode1

SteamFeed.D1

AAHPGenMode2

LPUSE.D1

AALPUseMode1

LPUSE.D1

AALPUseMode2

PWRUSE.D1

AAPower

HPUSE.D1

EtAcHPUse

LPGEN.D1

EtAcLPGen

PWRUSE.D1

EtAcPower

HPUSE.D1

VAMHPUse

LPUSE.D1

VAMLPUse

PWRUSE.D1
VAMPower
Configured DemandCalcs Table

Appendix 1 Configuring the Demand Forecasting Editor

Index

A
Adding data to the blocks 8
Aspen Utilities menu bar in
Microsoft Excel 94
Aspen Utilities models
creating 8
selecting 8
Aspen Utilities windows 5
AspenTech support 3
AspenTech Support Center 3
Availability profile 17
C
customer support 3
D
Demand
air 122
blocks 120
dual fuel 123
fuel 121
min. and max. flow limits 120
power 121
steam 120
Demand profile 13
documentation 2
E
e-bulletins 3
Emissions models
Burner 169
EmissionsChemney 172
EmissionsNode 173
EmissionsSwitch 174
NOXEstimator 175

Index

Equipment constraints 111


Equipment filter 21
F
Feed blocks 116
Filter types
equipment 21
Fuel models
boiler 154
combustor 158
df_boiler 156
FuelMixer 168
FuelSwitch1toN 169
gas turbine 158
HRSG 166
H
Headers
air mix 126
fuel 125
power 126
steam 124, 151, 152, 153
Heat exchangers
airairexchanger 150
as_heatex 142
chiller 143
condenser 145
fuelvap 145
heater 146
heater_1 147
ww_heatex 148
help desk 3
Hot standby requirements 71
I
Initializing physical properties 6

197

Installing the Microsoft Excel addin 93


M
Microsoft Excel
add-in 93
Aspen Utilities menu bar 94
simulation links worksheet 96
Model
limits 111
lists 112
standard variable names 114
structure 113
Multi-period optimization 109
P
Port types 115
Profile types
availability 17
demand 13
Profiles data editor
accessing 14, 33
availability profile data 17
availabilty profile 17
demand profile 13
overview 12
using 13, 48
Pumps
drive list 134
pump 132
pump list 136

T
Tariff data editor
contract definition table 34
data required 35
editing the add contract dialog
36, 39
overview 32
using 32
technical support 3
Templates 177
Turbines
stm_turbine 137, 139
U
Utility supply blocks 116
V
Viewing results from Microsoft
Excel 93
W
web site, technical support 3

S
Section contents 2
Simulation mode 8
Starting a simulation 9
Starting Aspen Utilities 5
Startup/shutdown constraints 73
Steam models
deaerator 127
desuperheater 129
sim_valve 128
stm_flash 130
stm_mix 131
Stream types 115
support, technical 3

198