Objective
After completing this workshop, youll be able to provide sufficient information to fully
define the thermodynamic basis of a simulation flowsheet. Additionally, you will be able
to fully define material streams and attach Stream Analyses to those streams to gain
further information.

Description
This workshop introduces you to some of the basic concepts necessary for creating
simulations in Aspen HYSYS. You will use Aspen HYSYS to define a hydrocarbon
stream which mimics the makeup and conditions of a typical upstream material flow. In
addition, you will learn how to determine specific properties of the stream by using the
Envelope and Property Table Analysis options.
This workshop includes the following tasks:

Task 1 Defining a Fluid Package


Task 2 Adding Streams
Task 3 Selecting a Unit Set
Task 4 Stream Analysis

Task 1 Defining a Fluid Package


Aspen HYSYS uses the concept of the Fluid Package to contain all necessary information
for performing flash and physical property calculations. This approach allows you to
define all information (property package, components, hypothetical components,
interaction parameters, reactions, tabular data, etc.) inside a single object.
The Properties Environment is a program view that allows you to create and manipulate
multiple fluid packages or component lists in the simulation. To re-enter the Properties
Environment from any point in the simulation, use the Ctrl+B hot key or select the
Properties Environment menu in the bottom-left of your HYSYS window.

2015 AspenTech. All Rights Reserved.

3 - 13

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

The first item shown in the Properties Environment is the Component Lists folder. Here,
you can create component lists that are independent of (but can be associated with) the
individual Fluid Packages in the case.

2015 AspenTech. All Rights Reserved.

3 - 14

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

The following table describes the various buttons available on the Component Lists
object:
Button

Description

Add

Allows you to create a Component List. You can choose between


the HYSYS Databanks and Aspen Properties databases when
creating a component list.
Note: Component Lists can be added through the Fluid Package
as well.

Delete

Removes the selected Component List from the simulation.

Copy

Makes a copy of the selected Component List.

Import

Allows you to import a predefined Component List from disk.


Component Lists have the file extension .cml.

Export

Allows you to export the selected Component List to disk. The


exported Component List can be retrieved into another case by
using the Import function.

The second folder in the Properties Environment is the Fluid Packages item. Depending
upon the desired property model, you have a choice between three available databases
when selecting a Fluid Package: Aspen HYSYS, Aspen Properties, or COMThermo. For
the workshops in this course, we will be using Aspen HYSYS as the database source.
The following table describes the various buttons available on the Fluid Packages object:
Button

Description

Add

Allows you to create and install a fluid package in the simulation.

Delete

Removes the selected Fluid Package from the simulation.

Copy

Makes a copy of the selected fluid package. Everything is identical


in the copied version except the name. This is useful for modifying
fluid packages.

Import

Allows you to import a predefined fluid package from disk. Fluid


packages have the file extension (.fpk).

Export

Allows you to export the selected fluid package to a disk. The


exported fluid package can be retrieved into another case by
using the Import function.

Now that you have been introduced to the Properties Environment of Aspen HYSYS,
lets begin the workshop.

2015 AspenTech. All Rights Reserved.

3 - 15

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Start a new case by opening Aspen HYSYS and selecting the New option.

On the Component Lists folder in the Navigation Pane, click the Add button.
Start by adding the first component; in this case it will be Nitrogen. Add it by
typing nitrogen or N2 into the Search for field in the component list window.

Once the desired component is highlighted click the <Add> button to add the
component to your component list.

2015 AspenTech. All Rights Reserved.

3 - 16

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Repeat this procedure by adding the following components:

Components
H2S
CO2
Methane
Ethane
Propane
i-Butane
n-Butane
i-Pentane
n-Pentane
n-Hexane
H2O
Note: You can select multiple components by holding down Ctrl on your keyboard and
selecting the desired components. Or hold down Shift and select a range of components.

2015 AspenTech. All Rights Reserved.

3 - 17

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Next you will introduce a hypothetical component to your list. This hypothetical
component will represent a mixture of heavier hydrocarbons (i.e. heptanes, octanes, etc.)
in the gas stream mixture.

Click the Select menu item and choose the Hypothetical option.

In the Method menu item, choose the Create and Edit Hypos option. This will
allow you to quickly create a single hypothetical component.

Again, you are adding a hypothetical component to represent an aggregate of


heavier hydrocarbons (i.e. n-heptane and heavier). To create this component,
click the New Hypo button.

2015 AspenTech. All Rights Reserved.

3 - 18

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

A single hypothetical component is created. Change the name from Hypo20000*


to C7+.

Note: When you click New Hypo, Aspen HYSYS adds a hydrocarbon class hypo by
default. If you want to add a hypo from another class, click the Hypothetical Manager
button in the Home tab of the ribbon and then in the view that displays, click the Settings
tab. This will open a form where you can add non-hydrocarbon class hypotheticals.

In the view for the hypo component you created, enter the Normal Boiling Point
for the component, which in our case is 110 C (230 F). No other properties are
90known, so everything else will be estimated.

Note: Aspen HYSYS always places an asterisk (*) after a hypo name so it can be
distinguished from databank components.

Click the Estimate Unknown button to estimate all the other properties and fully
define the hypothetical component.

Note: The minimum information required for defining a hypo is the Normal Boiling Pt or
the Molecular Weight and Liquid Density.

2015 AspenTech. All Rights Reserved.

3 - 19

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

When the hypo component has been defined, make sure the hypo component is
selected and highlighted.

Add the hypo component to the Selected Components list by selecting it and
clicking the < Add button.

You have now finished defining the component list. Using the Navigation Pane
on the left-hand side of the HYSYS window, select the Fluid Packages folder.

Click the Add button to add a Fluid Package. By default, it will be a HYSYS
Databank Fluid Package. This agrees with our component list as it was also set
up with the HYSYS Databank.

2015 AspenTech. All Rights Reserved.

3 - 20

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

From the Property Package Selection menu, choose the Peng-Robinson


property package.

Note: You can also verify your component list selection from the Fluid Packages menu.
Click the View button next to the Component List Selection field to double-check your
components.

Back in the Navigation Pane, click on the Fluid Packages folder icon. This will
show any created Fluid Packages and show the Fluid Package manipulation
buttons discussed earlier.
Click and highlight the current Fluid Package name Basis-1 and rename it as
GasPlant.

Once defined, Fluid Packages can be exported for use in another HYSYS case, creating a
single, common physical property source that can be used across multiple simulations.

2015 AspenTech. All Rights Reserved.

3 - 21

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Make sure the GasPlant Fluid Package is highlighted and click the Export button
at the bottom of the form.

Browse to a suitable file-save location (i.e. a folder on the Desktop, a personal


drive, etc.) and enter GasPlant as the name for the Fluid Package. Then click
Save.Gs

Note: Aspen HYSYS will automatically add the file extension .fpk when it saves your fluid
package. By default, the file is automatically saved to the Program Files folder \Aspen
HYSYS V8.8\Paks. It is preferred instead to save the .fpk file to a local, personal, or
easily accessible shared drive location.

Task 2 Adding Streams


Now that your Fluid Package has been defined, you can continue with the simulation by
adding a Material Stream.

Click the Simulation Environment button to begin building the flowsheet.

2015 AspenTech. All Rights Reserved.

3 - 22

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

In Aspen HYSYS, there are two types of streams that can be added to a flowsheet;
material streams and energy streams. Material streams are used to represent process flows
and have defined parameters such as composition, temperature, pressure, and flow rate.
Energy streams are typically used to represent the heat duty or energy supplied to or
produced by a unit operation. Energy streams have only one parameter; heat flow. There
are a variety of ways to add material streams in Aspen HYSYS:

To use this...

Do this...

Object
Palette

View the Object Palette (press F4 to show if its


unavailable). Double-click the Material Stream icon or click
and drag it onto the flowsheet.

Keyboard
Shortcut

Press the F11 Hot Key. The Stream property view opens.

Ribbon

From the Flowsheet/Modify tab, select the Additional


Flowsheet Commands link and choose Add Stream.

Using the Object Palette (or one of the other described means) add a Material
Stream to your flowsheet.
If the stream property view is not displayed, double-click the newly created
stream in the flowsheet to bring up the property view, shown below:

2015 AspenTech. All Rights Reserved.

3 - 23

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Highlight the Stream Name cell. Change the stream name to HC Feed and press
Enter.

Once a material stream has been created, there are two different methods that can be used
to enter stream composition:
On this page...

Do this...
Double-click the Molar Flow cell to enter mole fractions.

Conditions
or

Double-click the Mass Flow cell to enter mass fractions.


or
Double-click the Std Ideal Liquid Volume Flow cell to enter
volume fractions.
The Input Composition for Stream view displays.
Composition

Click the Edit button.


The Input Composition for Stream view displays.

2015 AspenTech. All Rights Reserved.

3 - 24

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Use one of the methods described above to open the Input Composition for
Stream view.

Ensure that Mole Fractions is displayed as the Composition Basis and enter the
following values:
For this component...

Enter this mole fraction...

Nitrogen

0.0083

H2S

0.0211

CO2

0.0107

Methane

0.5091

Ethane

0.1766

Propane

0.0752

i-Butane

0.0508

n-Butane

0.0398

i-Pentane

0.0441

n-Pentane

0.0339

n-Hexane

0.0202

H2O

0.0000

C7+

0.0102

2015 AspenTech. All Rights Reserved.

3 - 25

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Click OK to save the compositions and close the Input Composition for Stream
window.
Now is a good opportunity to save your progress. Select the File tab in the
Ribbon and choose Save As. Browse to a suitable file-save location and save the
case as 02-GettingStarted.hsc.

Once composition has been defined, Aspen HYSYS can perform three types of flash
calculations on streams: Pressure-Temperature, Vapor Fraction-Temperature and Vapor
Fraction-Pressure. While enthalpy and entropy are also available to be specified for flash
calculations, this is not typically done. If two of the three process variables are known
(pressure, temperature and vapor fraction), Aspen HYSYS can perform a flash
calculation on the stream to calculate the third parameter, as well as the molar enthalpy
and molar entropy.
Note: Only two of these three stream parameters (pressure, temperature and vapor
fraction) can be supplied. If all three variables are somehow defined, a consistency error
will occur.

Perform a P-T flash calculation on the HC Feed stream by setting the pressure to
3000 kPa (435 psia) and the temperature to 25 C (77 F).
What is the resulting vapor fraction?

With the flash capabilities of Aspen HYSYS, it is possible to perform dew point and
bubble point calculations with ease. By specifying a vapor fraction of 1.0 and either the
pressure or temperature of the stream, Aspen HYSYS will determine the dew point
condition. Similarly, to calculate the bubble point, a vapor fraction of 0.0 and either the
stream pressure or temperature must be entered.

Delete the specified temperature and enter a vapor fraction of 1.0. What is the
dew point temperature at 3000 kPa (435 psia)?

Change the vapor fraction to 0.0. What is the bubble point temperature?

Delete the vapor fraction specification and return the temperature to its original
value of 25 C (77 F).

2015 AspenTech. All Rights Reserved.

3 - 26

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

The HC Feed stream is still not yet fully defined. In order to fully define a
stream, you must enter a molar, mass, or volumetric flow rate.
Enter a molar flow rate of 9000 kgmole/h (19840 lbmole/hr).
What is the Standard Gas Flow of the vapor phase?

Hint: To find the standard gas flow rate, select the Properties page from the stream
menu. Then move the mouse arrow to the left or right side of the view until the arrow
changes to the double-headed resizing arrows. Press and hold the left mouse button and
drag the edge of the view until all the phases can be seen.

2015 AspenTech. All Rights Reserved.

3 - 27

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Task 3 Selecting a Unit Set


In Aspen HYSYS, it is possible to change the default unit set used to display variables on
a case-wide basis. Two approaches can be taken to change the unit set, and both will be
reviewed in the following steps,

View the Home tab in the HYSYS ribbon. The Units selector is on the left hand
side:

Click the pull-down menu to select a unit set. There are three default unit sets
available: SI, EuroSI, and Field (English/Imperial).

2015 AspenTech. All Rights Reserved.

3 - 28

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

To access further unit set options, follow one of these approaches:


o Click the Unit Sets button below the unit set selector.
o Go to the File tab, and click the Options button.

2015 AspenTech. All Rights Reserved.

3 - 29

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

In the resulting Simulation Options window, make sure you are viewing the Units
of Measure from.

You can click and select a desired unit set for use, or even create your own
custom unit set by copying an existing set. In this exercise we will use one of the
built-in sets, so choose your preferred set and click OK.

Note: To change the units for an individual input specification, simply type the numerical
value of the specification and click the unit drop-down list. Choose the desired unit for
the value you are providing and Aspen HYSYS will convert the input back to the default
unit selected in your session preferences.

2015 AspenTech. All Rights Reserved.

3 - 30

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Task 4 Stream Analysis


In Aspen HYSYS, the Home tab contains a set of useful Analysis tools that interact with
your process. These tools provide additional information or analysis of streams or
operations. Once installed, the Analysis becomes part of the simulation, automatically
recalculating when conditions change in the stream or operation to which it is attached.
As with the majority of objects in Aspen HYSYS, Analyses can be attached to streams in
one of several different ways:
To use the...

Do this...

Ribbon

From the Home tab, select Stream Analysis. Or select


the pull-down arrow on the Stream Analysis button to
choose a particular analysis type.

Stream Property
View

1. Open the Stream property view.


2. On the Attachments tab, click the Analysis page.
3. Click the Create button.
The Available Stream Analysis view displays.

Navigation Pane

Click and select the Stream Analysis folder in the


Navigation Pane. Then click the Add button and select
the desired Analysis type.

The Envelope Analysis allows you to examine relationships between selected parameters
for any stream of known composition, including streams with only one component.
Vapor-Liquid phase envelopes may be plotted for the following variables: PressureTemperature, Pressure-Volume, Pressure-Enthalpy, Pressure-Entropy, TemperatureVolume, Temperature-Enthalpy and Temperature-Entropy.

Open the HC Feed stream property view by double-clicking on the stream icon
on the flowsheet.

On the Attachments tab, click Analysis on the left side of the page.

2015 AspenTech. All Rights Reserved.

3 - 31

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Click the Create button. The Available Stream Analysis view will appear.

Once the Available Stream Analysis menu appears, select Envelope and click the
Add button.
You should notice that an analysis titled Envelope-HC Feed is now listed. Make
sure it is highlighted and click the View button.

2015 AspenTech. All Rights Reserved.

3 - 32

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

The Envelope Analysis window should now be visible.


The Design tab shows the critical points and maxima for the phase envelope.
What is the critical temperature and pressure for the stream HC Feed?

Switching to the Performance tab allows you to view the graphical and tabular
representation of the phase envelope, as shown below.

Note: Numerical values can be copied from the results table in Aspen HYSYS to
Microsoft Excel using the copy command (Ctrl+C) in Aspen HYSYS and then the paste
command (Ctrl+V) in Excel.
The next Analysis you will use is the Property Table Analysis. The Property Table
Analysis allows you to examine physical property trends over a range of conditions in
both tabular and graphical formats. The analysis calculates dependent variables from
user-specified independent variable ranges (or values).

Viewing the Home tab in the HYSYS ribbon, click the Stream Analysis button.

The resulting view is into the Stream Analysis folder in the Navigation Pane.
You should see your Envelope Analysis listed here.

2015 AspenTech. All Rights Reserved.

3 - 33

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Click and select the Add button. This will let you choose a particular Analysis
option. Select the Property Table.

The analysis must be linked to a given stream. In the Select Process Stream
window, choose HC Feed as the Object, and then click OK.
You should now see the created analysis in the Navigation Pane, titled Property
Table-HC Feed. Click on it to select and open it.

2015 AspenTech. All Rights Reserved.

3 - 34

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

The first step in building a Property Table is to define desired independent


variables. Instead of using the default Independent Variables, re-write them as
follows:
Independent Variable 1

Independent Variable 2

Variable 1

Pressure

Variable 2

Temperature

Mode

State

Mode

Incremental

State Values

2500 kPa (362.6 psia)

Lower Bound

0 C (32 F)

5000 kPa (725.2 psia)

Upper Bound

100 C (212 F)

7500 kPa (1088 psia)

# of Increments

10

9000 kPa (1305 psia)

Select the Design | Dep. Prop page and click the Add button.

2015 AspenTech. All Rights Reserved.

3 - 35

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Choose Mass Density from the list. Click OK to accept.

You will bring in one more dependent variable, so click Add again. Select the
Phase Thermal Conductivity | Vapour Phase and click OK to accept.
Click the Calculate button at the bottom of the view to generate the property
table.

Note: If the properties of the attached stream change, the Property Table utility will need
to re-calculate in order to update the results. You must manually re-click the Calculate
button!

2015 AspenTech. All Rights Reserved.

3 - 36

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Examine the property table results in either graphical or tabular format on the
Performance tab.

Close the Property Table.


Save your case once again using the same file name (02-GettingStarted.hsc).

2015 AspenTech. All Rights Reserved.

3 - 37

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Challenge Exercises

Use the Envelope Analysis to determine the cricondenbar of stream HC Feed.


Discern the dew point temperature of stream HC Feed at 7000 kPa (1015 psia)
using the Envelope analysis.
How does this compare to a rigorous flash calculation using the stream property
view?

Hint: Hover over the plot and use the Cross Hairs to more accurately assess the position
of the cursor.

Plot the 50% quality line for stream HC Feed. What temperature corresponds to
50 atm on this graph?

Hint: Right click on the plot and use the Graph Control dialog to change the display units
for Pressure.

Recommended Reading
Knowledge Base Solution 109322
How do I plot an envelope on a wet basis?
Knowledge Base Solution 109812
Calculate a phase envelope using the property table utility

2015 AspenTech. All Rights Reserved.

3 - 38

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Getting Started Solutions


Files can be found in folder: 02_GettingStarted/Solutions

Questions
Task 2

Perform a P-T flash calculation on the HC Feed stream by setting the pressure to
3000 kPa (435 psia) and the temperature to 25 C (77 F). What is the resulting
vapor fraction?

0.7333

What is the dew point temperature at 3000 kPa (435 psia)?

90.49 C (194.9 F)

What is the bubble point temperature at the same pressure?

-78.57 C (-109.4 F)

What is the Standard Gas Flow of the vapor phase?

156000 STD_m3/h (132.3 MMSCFD)

Task 4

What is the critical temperature and pressure for the stream HC Feed?

66.93 C (152.5 F) and 12220 kPa (1772 psia)

2015 AspenTech. All Rights Reserved.

3 - 39

Aspen Technology, Inc.

Aspen HYSYS: Process Modeling

Getting Started Workshop

Challenge Problems

Use the Envelope Analysis to determine the cricondenbar of stream HC Feed.

12310 kPa (1785 psia)

Discern the dew point temperature of stream HC Feed at 7000 kPa (1015 psia)
using the Envelope analysis.

104.9 C (220.9 F); approximate solution found by hovering mouse/cross hairs over the
dew point curve on the Envelope plot

How does this compare to a rigorous flash calculation using the stream property
view?

103.8 C (218.8 F) for the rigorous flash

Plot the 50% quality line for stream HC Feed. What temperature corresponds to
50 atm on this graph?