Vous êtes sur la page 1sur 3

AmSolv 9350

Ch phm x l nc trong cng nghip


Lm sch h thng nc tun hon
Loi b cu cn, n mn, cht phn tn v cht c ch
M T: AmSolv 9350 l mt ch phm m c 3 chc nng c tnh cht kim. N c s
dng hiu qu trong vic loi b, phn tn v ngn nga hin tng bm dnh ca cu cn, n mn,
v cc hp cht hu c. N s dng c trong hu ht cc h thng lm mt tun hon h v kn
v h thng nc nng.
U IM: AmSolv 9350 l mt sn phm ti u cho vic lm sch online v ty sch h
thng mi lp t, n c kh nng ha tan, lm phn tn cc cht du, m, cu cn, r st, bn bm
v cc cht hu c bm trong h thng ng ng mi v c. AmSolv 9350 l ch phm khng
n mn c s dng th ng ha b mt, to ra mt lp mng bo v gip cho h thng khng
b hin tng n mn. Trong nhng h thng c v h thng b cu cn nhiu gy tc nghn th thi
gian ty sch c th mt hng tun i vi h thng kn v hng thng i vi h thng h. Ch
phm AmSolv 9350 khng cha axit hay cc kim loi nng.
CC CH DN: Liu lng s dng AmSolv 9350 cho cc h thng c hay cc h thng mi l
2,000 ppm so vi tng lng nc trong h thng khi lm sch on-line. H thng hot ng hon
ton bnh thng trong sut qu trnh lm sch. Chng ta cn phi kim tra thng xuyn h thng
nhm theo di kt qu ca qu trnh ty sch: Vi h thng kn l mi tun 1 ln. Tin hnh x y
lin tc h thng khi nc t n ngng bo ha cc cht cu cn. Lp li quy trnh ty cho
n khi h thng hon ton sch.
i vi h thng tun hon h Cooling towers: tin hnh x y khi thy nc trong h thng tr
ln bn, qu trnh x y c th tin hnh sau mt vi ngy k t khi a ha cht vo h thng
tun hon. Sau , cho thm ha cht vi liu lng ph hp nhm ty sch hon ton cu cn
trong h thng. Qu trnh x y v ra bng nc sch loi b ton b cht bn bn v cc tp
cht l hon ton cn thit.
CH : V cha kim nn gy au mt v rt da khi b giy vo. Nu b bn vo mt th cn phi
ra tht nhiu bng nc l, lm theo ch dn ca bc s. Nu b bn vo da, hy ci bo ra v tm
ngay bng nc m, nu vn thy bng rt th phi gi ngay cho bc s. Nu nut phi th cn phi
ung tht nhiu nc v i gp bc s ngay. Trnh xa tm tay vi ca tr em

Total Water Management

AmSolv 9350

Industrial Water Treatment Compound


Recirculating Water System Cleaner
Scale & Corrosion Remover, Dispersant and Inhibitor
DESCRIPTION:
AmSolv 9350 is a concentrated alkaline, triple purpose product. It gently and effectively removes, disperses and prevents accumulations
of scale, corrosion, and organic matter. It does this in a wide range of open and closed recirculating cooling and heating water systems.
ADVANTAGES:
AmSolv 9350 is the product of choice for on line and new installation clean up jobs. Properly applied and controlled, it will solubilize and
disperse oil, grease, mill scale, rust, mineral scale, mud and organics that foul new and old piping systems. AmSolv 9350 is a noncorrosive
product that will passivate and protect system metals from corrosion. In old and heavily fouled systems, deposits are not removed so rapidly
that plugging occurs. In these systems clean up time can range from weeks for closed loop systems to several months for heavily scaled
cooling towers. AmSolv 9350 contains no acids or heavy metals.
DIRECTIONS:
AmSolv 9350 is slug dosed to the fouled old or newly constructed system at 2 gallons per 1,000 gallons of system water (2,000 ppm) for
on line clean up jobs. Systems should be placed into normal operation or circulation for the cleanup period. Closed loop systems should be
checked weekly. Flush system with on line bleed when the water becomes saturated with contaminants. Repeat this procedure until system
water remains clean for one week of system operation with AmSolv 9350 applied. Cooling towers should be drained and flushed after
recirculation as visual inspection dictates. Bleed should be reopened after the first few days of system recirculation. Thereafter, continuous
injection or regular slug additions must be made for as long as several months to clean scaled systems. Periodic flushing of the system to
remove sludge and loosened contamination will be necessary.
WARNING:
Contains potassium hydroxide. Eye and skin irritant. Avoid contact with skin and eyes. If eye contact occurs, flush with water for 15 minutes.
Get prompt medical attention. If skin contact occurs, remove contaminated clothing. Flush with warm water. If irritation persists, consult a
physician. Do not take internally. If swallowed, drink large quantities of water. Do not induce vomiting. Contact physician immediately. KEEP
OUT OF REACH OF CHILDREN.
Container Disposal: Triple rinse container and discard according to local regulations.
03/98

CAS NUMBERS: Water 7732-18-5; Potassium hydroxide 1310-58-3; Alkyl amphopropionate 70983-43-6; Hydroxyethylidenediphosphonic
acid 2809-21-4; Sodium Tolyltriazole Solution 64665-57-2.
HMIS RATING: Health-2; Flammability-0; Reactivity-0; Personal Protection-B.

CW-9350

945 E. Pleasant Run Road Lancaster, TX 75146 Phone: (888) 4-AmSolv / (972) 227-3304 Fax: (800) 362-4794 / (972) 227-8103 www.amsolv.com

MATERIAL SAFETY DATA SHEET


This MSDS complies with OSHA'S Hazard Communication Standard 29 CFR 1910.1200 and OSHA Form 174

IDENTITY AND MANUFACTURER'S INFORMATION


NFPA Rating: Health-2; Flammability-0; Reactivity-0; Special-

HMIS Rating: Health-2; Flammability-0; Reactivity-0; Personal Protection-B

DOT Hazard Classification: NON-HAZARDOUS


FDA: This product is approved under the following FDA (21 CFR) sections: Unknown.
Identity (trade name as used on label):
Manufacturer's Name: AmSolv Manufacturing Company.

Address:

1803 Howard Road


AmSolv 9350
Waxahachie, TX 75165
Date Prepared: 2005-07-05
Prepared By: STH
MSDS Number: WC9350
Revision - 1
Information Calls: 1 (972) 938-1401
INOTICE: JUDGMENT BASED ON INDIRECT TEST DATA
EMERGENCY RESPONSE NUMBER: 1 (972) 938-1410
(International)
SECTION 1 - MATERIAL IDENTIFICATION AND INFORMATION
COMPONENTS-CHEMICAL NAMES AND COMMON NAMES
(Hazardous Components 1% or greater; Carcinogens 0.1% or greater)
POTASSIUM HYDROXIDE

CAS Number

SARA
III LIST

OSHA PEL
(ppm)

1310-58-3

No

2mg/m3

ACGIH
Carcinogen
TLV (ppm) Ref. Source **

2mg/m3

SECTION 2 - PHYSICAL/CHEMICAL CHARACTERISTICS


Boiling Point: 100C
Vapor Pressure: PSIG @ 70F (Aerosols): N/A
Vapor Density (Air = 1): N/D
Solubility in Water: Soluble
Appearance and Odor: Clear, light yellow liquid with slight ammonia odor.

Specific Gravity (H2O=1): 1.18


Vapor Pressure (Non-Aerosols)(mm Hg and Temperature): N/D
Evaporation Rate (water = 1): 1.0
Water Reactive: No

SECTION 3 - FIRE AND EXPLOSION HAZARD DATA


FLAMMABILITY as per USA FLAME PROJECTION TEST
Auto Ignition Temperature
Flammability Limits in Air by % in Volume:
N/A
% LEL:
N/A
% UEL:
N/A
(aerosols)
N/A
FLASH POINT AND METHOD USED (non-aerosols): Non-combustible.
EXTINGUISHER MEDIA: Any media appropriate for surrounding fire
SPECIAL FIRE FIGHTING PROCEDURES: None
Unusual Fire & Explosion Hazards: Reaction of bare metal & this fluid could generate explosive hydrogen gas.

SECTION 4 - REACTIVITY HAZARD DATA


STABILITY
[ X ] STABLE [ ] UNSTABLE
Incompatibility (Mat. to avoid): Bare or reactive metals. Soft metals such as
aluminum.
Hazardous Decomposition Products: : None identified.

HAZARDOUS POLYMERIZATION [ ] WILL


Conditions to Avoid: None known

[ X ] WILL NOT

OCCUR

SECTION 5 - HEALTH HAZARD DATA


PRIMARY ROUTES OF ENTRY: [ X ] INHALATION [ X ] INGESTION [ ] SKIN ABSORPTION
ACUTE EFFECTS:
Inhalation: No known adverse affects.
Eye Contact: Irritant.
Skin Contact: Irritant.
Ingestion: Can cause gastrointestinal irritation.
CHRONIC EFFECTS: Skin burns can occur with alkaline fluids.
Medical Conditions Generally Aggravated by Exposure: None identified.

[ ] EYE

[ ] NOT HAZARDOUS

EMERGENCY FIRST AID PROCEDURES


Eye Contact: Flush with water for 15 minutes. Get immediate medical attention..
Skin Contact: Flush with water for at least 15 minutes.
Inhalation: Remove to fresh air..
Ingestion: DO NOT INDUCE VOMITING. Drink large quantity of water. Get immediate medical attention.

SECTION 6 - CONTROL AND PROTECTIVE MEASURES


Respiratory Protection (specify type): None required.
Protective Gloves: Rubber or chemical resistant.
Eye Protection: Chemical goggles or face shield.
Ventilation Requirements: Normal ventilation is adequate.
Other Protective Clothing & Equipment: Rubber boots and apron under splashing conditions. Eyewash station and safety shower.
Hygienic Work Practices: Do not eat, drink or smoke in work area. Wash hands after handling.

SECTION 7 - PRECAUTIONS FOR SAFE HANDLING AND USE


Steps To Be Taken If Material Is Spilled Or Released: Soak up in absorbent material & place in properly labeled, sealed, leak-proof containers.
Waste Disposal Methods: Dispose of in accordance with all local, state and federal regulations.
Precautions To Be Taken In Handling & Storage: Store in original container. Keep container sealed when not in use. Shelf life one year. Protect from extreme
heat or cold.
Other Precautions &/or Special Hazards: KEEP OUT OF REACH OF CHILDREN. Read and follow label directions.
We believe the statements, technical information and recommendations contained herein are reliable, but they are given without warranty or guarantee of any
kind.
** Chemical Listed as Carcinogen or Potential Carcinogen. [a] NTP [b] IARC Monograph [c] OSHA [d] Not Listed [e] Animal Data Only