Vous êtes sur la page 1sur 14

Girder3 LRFD Dist Factor

*****************************************************************
** Note that this file contains the distribution factors
**
** computed by the BrD wizard based on the bridge description **
** in BrD on the date and time below. These computed values
**
** may not match those shown in BrD if the user has changed
**
** the BrD bridge description after these distribution
**
** factors were computed.
**
*****************************************************************
Bridge: Congress Street Bridge
Bridge ID: Congress Street
BID: 93

NBI Structure ID: 2230390

Superstructure Def: SD-1


Member: G3
Member Alternative: Girder 3
Date:

10/31/2016

Time: 02:07:40 PM

AASHTO LRFD Bridge Design Specifications, Seventh Edition - 2014


Moment Distribution Factor Schedule
Start
End
Single Lane
Multi Lane
Distance
Distance
DF
DF
(ft)
(ft)
(Lanes)
(Lanes)
---------------------------------------------------------0.00
29.69
0.548(A)
0.723(A)
29.69
49.48
0.548(A)
0.723(A)
49.48
79.17
0.548(A)
0.723(A)
Shear Distribution Factor Schedule
Start
End
Single Lane
Multi Lane
Distance
Distance
DF
DF
(ft)
(ft)
(Lanes)
(Lanes)
---------------------------------------------------------0.00
39.58
0.693(A)
0.838(A)
39.58
79.17
0.693(A)
0.838(A)
Deflection Distribution Factor Schedule
Start
End
Single Lane
Multi Lane
Distance
Distance
DF
DF
(ft)
(ft)
(Lanes)
(Lanes)
---------------------------------------------------------0.00
79.17
0.150(A)
0.150(A)
Reaction Distribution Factor Schedule
Support
Deflect

Moment
DF

Single Lane
Shear
DF

Deflect
DF

Moment
DF

Multi Lane
Shear
DF

DF
(Lanes)
(Lanes)
(Lanes)
(Lanes)
(Lanes)
(Lanes)
---------------------------------------------------------------------------------------------1
0.548 (A)
0.693 (A)
0.150 (A)
0.723 (A)
0.838 (A)
Page 1

Girder3 LRFD Dist Factor


0.150 (A)
2
0.150 (A)
3
0.150 (A)

0.548 (A)

0.693 (A)

0.150 (A)

0.723 (A)

0.838 (A)

0.548 (A)

0.693 (A)

0.150 (A)

0.723 (A)

0.838 (A)

Legend:
(A)

= AASHTO Equations

(L)

= AASHTO Lever Rule in AASHTO Tables

(LO) = Lever Rule Override


(R)

= Rigid Deck Distribution

===========================
== Detailed Calculations ==
===========================
=======================
Lever Rule Distribution
(Article 4.6.2.2)
=======================
Compute Lever Rule Deck Distribution Factors
-------------------------------------------Number Lanes Loaded = 1
Truck Wheel Positions from Left Edge of Deck
Truck
Left Wheel
Right Wheel
(ft)
(ft)
-------------------------------------------1
25.95
31.95
Lever Rule Reaction, R =
Lever DF = MPF * R = 1.20 *

0.034
0.034

0.040 Lanes

Note:
Only 1 truck can be applied to this beam.
The single lane lever rule DF will be divided by 1.2 (MPF) to obtain the multi lane
lever rule DF.
====================================
Moment Distribution Factors
====================================
-------------------------------------Region 1
-------------------------------------Page 2

Start Distance:
End Distance:
Moment Type:
Properties at:
Theta:

Girder3 LRFD Dist Factor


0.00(ft)
29.69(ft)
Positive
14.84(ft)
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

-------------------------------------Region 2
-------------------------------------Start Distance:
29.69(ft)
End Distance:
49.48(ft)
Moment Type:
Negative
Page 3

Properties at:
Theta:

Girder3 LRFD Dist Factor


39.58(ft)
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

-------------------------------------Region 3
-------------------------------------Start Distance:
49.48(ft)
End Distance:
79.17(ft)
Moment Type:
Positive
Properties at:
64.32(ft)
Theta:
0.00(Deg)
Page 4

Girder3 LRFD Dist Factor


Longitudinal Stiffness Parameter, Kg, Calculation
(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

-------------------------------------Support 1
-------------------------------------Start Distance:
0.00(ft)
End Distance:
0.00(ft)
Properties at:
0.00(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
Page 5

Girder3 LRFD Dist Factor


------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

-------------------------------------Support 2
-------------------------------------Start Distance:
39.58(ft)
End Distance:
39.58(ft)
Properties at:
39.58(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
Page 6

Girder3 LRFD Dist Factor


A =
eg =

51.96(in^2)
18.41(in)

Kg = n(I + Aeg^2) (4.6.2.2.1-1)


Kg =
225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

-------------------------------------Support 3
-------------------------------------Start Distance:
79.17(ft)
End Distance:
79.17(ft)
Properties at:
79.17(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2)

(4.6.2.2.1-1)
Page 7

Girder3 LRFD Dist Factor


Kg =

225472.34(in^4)

---------------------------------------------------------------Live Load Distribution Factor for Moment in Interior Beams


(Article 4.6.2.2.2b Interior Beams with Concrete Decks)
---------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Check Range of Applicability
---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
ts =
L =
Nb =
Kg =

8.33(ft)
9.00(in)
39.58(ft)
8
225472.34(in^4)

3.5 <= S <= 16.0:


4.5 <= ts <= 12.0:
20 <= L <= 240:
Nb >= 4:
10,000 <= Kg <= 7,000,000:

PASSED
PASSED
PASSED
PASSED
PASSED

Compute Moment Distribution Factors


----------------------------------Input:
S
=
8.33(ft)
ts
=
9.00(in)
L
=
39.58(ft)
Kg
=
225472.3(in^4)
Theta =
0.00(Deg)
One Design Lane Loaded:
DF = 0.06 + (S/14.0)^0.4 * (S/L)^0.3 * (Kg/(12.0L(ts^3)))^0.1 =

0.548 Lanes

Two or More Design Lanes Loaded:


DF = 0.075 + (S/9.5)^0.6 * (S/L)^0.2 * (Kg/(12.0L(ts^3)))^0.1 =

0.723 Lanes

====================================
Shear Distribution Factors
====================================
-------------------------------------Region 1
-------------------------------------Start Distance:
0.00(ft)
End Distance:
39.58(ft)
Properties at:
19.79(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Page 8

Girder3 LRFD Dist Factor


Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

Check Range of Applicability


---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
L =
ts =
Nb =

8.33(ft)
39.58(ft)
9.00(in)
8

3.5 <= S <= 16.0:


20 <= L <= 240:
4.5 <= ts <= 12.0:
Nb >= 4:

PASSED
PASSED
PASSED
PASSED

-------------------------------------------------------------Live Load Distribution Factor for Shear in Interior Beams


(Article 4.6.2.2.3a Interior Beams)
-------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Compute Shear Distribution Factors
----------------------------------Input:
S =
8.33(ft)
One Design Lane Loaded:
DF = 0.36 + (S/25.0) =

0.693 Lanes

Two or More Design Lanes Loaded:


DF = 0.2 + (S/12.0) - (S/35.0)^2.0 =

0.838 Lanes

-------------------------------------Region 2
-------------------------------------Start Distance:
39.58(ft)
End Distance:
79.17(ft)
Properties at:
59.37(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

Check Range of Applicability


---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Page 9

Girder3 LRFD Dist Factor


Input:
S =
L =
ts =
Nb =

8.33(ft)
39.58(ft)
9.00(in)
8

3.5 <= S <= 16.0:


20 <= L <= 240:
4.5 <= ts <= 12.0:
Nb >= 4:

PASSED
PASSED
PASSED
PASSED

-------------------------------------------------------------Live Load Distribution Factor for Shear in Interior Beams


(Article 4.6.2.2.3a Interior Beams)
-------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Compute Shear Distribution Factors
----------------------------------Input:
S =
8.33(ft)
One Design Lane Loaded:
DF = 0.36 + (S/25.0) =

0.693 Lanes

Two or More Design Lanes Loaded:


DF = 0.2 + (S/12.0) - (S/35.0)^2.0 =

0.838 Lanes

-------------------------------------Support 1
-------------------------------------Start Distance:
0.00(ft)
End Distance:
0.00(ft)
Properties at:
0.00(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

Check Range of Applicability


---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
L =
ts =
Nb =

8.33(ft)
39.58(ft)
9.00(in)
8

3.5 <= S <= 16.0:


20 <= L <= 240:
4.5 <= ts <= 12.0:
Nb >= 4:

PASSED
PASSED
PASSED
PASSED

-------------------------------------------------------------Live Load Distribution Factor for Shear in Interior Beams


(Article 4.6.2.2.3a Interior Beams)
-------------------------------------------------------------Page 10

Girder3 LRFD Dist Factor


Cross section type: Type A from Table 4.6.2.2.1-1
Compute Shear Distribution Factors
----------------------------------Input:
S =
8.33(ft)
One Design Lane Loaded:
DF = 0.36 + (S/25.0) =

0.693 Lanes

Two or More Design Lanes Loaded:


DF = 0.2 + (S/12.0) - (S/35.0)^2.0 =

0.838 Lanes

-------------------------------------Support 2
-------------------------------------Start Distance:
39.58(ft)
End Distance:
39.58(ft)
Properties at:
39.58(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

Check Range of Applicability


---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
L =
ts =
Nb =

8.33(ft)
39.58(ft)
9.00(in)
8

3.5 <= S <= 16.0:


20 <= L <= 240:
4.5 <= ts <= 12.0:
Nb >= 4:

PASSED
PASSED
PASSED
PASSED

-------------------------------------------------------------Live Load Distribution Factor for Shear in Interior Beams


(Article 4.6.2.2.3a Interior Beams)
-------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Compute Shear Distribution Factors
----------------------------------Input:
S =
8.33(ft)
One Design Lane Loaded:
DF = 0.36 + (S/25.0) =

0.693 Lanes
Page 11

Girder3 LRFD Dist Factor


Two or More Design Lanes Loaded:
DF = 0.2 + (S/12.0) - (S/35.0)^2.0 =
0.838 Lanes
-------------------------------------Support 3
-------------------------------------Start Distance:
79.17(ft)
End Distance:
79.17(ft)
Properties at:
79.17(ft)
Theta:
0.00(Deg)

Longitudinal Stiffness Parameter, Kg, Calculation


(Article 4.6.2.2 Beam-Slab Bridges)
------------------------------------------------Input:
n =
9.19
I =
6936.20(in^4)
A =
51.96(in^2)
eg =
18.41(in)
Kg = n(I + Aeg^2) (4.6.2.2.1-1)
Kg =
225472.34(in^4)

Check Range of Applicability


---------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Input:
S =
L =
ts =
Nb =

8.33(ft)
39.58(ft)
9.00(in)
8

3.5 <= S <= 16.0:


20 <= L <= 240:
4.5 <= ts <= 12.0:
Nb >= 4:

PASSED
PASSED
PASSED
PASSED

-------------------------------------------------------------Live Load Distribution Factor for Shear in Interior Beams


(Article 4.6.2.2.3a Interior Beams)
-------------------------------------------------------------Cross section type: Type A from Table 4.6.2.2.1-1
Compute Shear Distribution Factors
----------------------------------Input:
S =
8.33(ft)
One Design Lane Loaded:
DF = 0.36 + (S/25.0) =

0.693 Lanes

Two or More Design Lanes Loaded:


DF = 0.2 + (S/12.0) - (S/35.0)^2.0 =

0.838 Lanes

====================================
Deflection Distribution Factors
====================================
-------------------------------------Page 12

Girder3 LRFD Dist Factor


Region 1
-------------------------------------Start Distance:
0.00(ft)
End Distance:
79.17(ft)

Compute Deflection Distribution Factors


(Article 2.5.2.6.2)
--------------------------------------Input:
Number lanes = 1
1 Lane MPF = 1.20
Number beams = 8
2 Lane MPF = 1.00
3 Lane MPF = 0.85
>3 Lane MPF = 0.65
One Design Lane Loaded:
DF = 1.0/Number beams * MPF = 1.0/8 * 1.20 =

0.150 Lanes

Two or More Design Lanes Loaded:


DF = Number lanes/Number beams * MPF = 1/8 * 1.20 =

0.150 Lanes

-------------------------------------Support 1
-------------------------------------Start Distance:
0.00(ft)
End Distance:
0.00(ft)

Compute Deflection Distribution Factors


(Article 2.5.2.6.2)
--------------------------------------Input:
Number lanes = 1
1 Lane MPF = 1.20
Number beams = 8
2 Lane MPF = 1.00
3 Lane MPF = 0.85
>3 Lane MPF = 0.65
One Design Lane Loaded:
DF = 1.0/Number beams * MPF = 1.0/8 * 1.20 =

0.150 Lanes

Two or More Design Lanes Loaded:


DF = Number lanes/Number beams * MPF = 1/8 * 1.20 =
-------------------------------------Support 2
-------------------------------------Start Distance:
39.58(ft)
End Distance:
39.58(ft)

Compute Deflection Distribution Factors


(Article 2.5.2.6.2)
--------------------------------------Input:
Number lanes = 1
1 Lane MPF = 1.20
Number beams = 8
2 Lane MPF = 1.00
3 Lane MPF = 0.85
>3 Lane MPF = 0.65
Page 13

0.150 Lanes

Girder3 LRFD Dist Factor


One Design Lane Loaded:
DF = 1.0/Number beams * MPF = 1.0/8 * 1.20 =

0.150 Lanes

Two or More Design Lanes Loaded:


DF = Number lanes/Number beams * MPF = 1/8 * 1.20 =

0.150 Lanes

-------------------------------------Support 3
-------------------------------------Start Distance:
79.17(ft)
End Distance:
79.17(ft)

Compute Deflection Distribution Factors


(Article 2.5.2.6.2)
--------------------------------------Input:
Number lanes = 1
1 Lane MPF = 1.20
Number beams = 8
2 Lane MPF = 1.00
3 Lane MPF = 0.85
>3 Lane MPF = 0.65
One Design Lane Loaded:
DF = 1.0/Number beams * MPF = 1.0/8 * 1.20 =

0.150 Lanes

Two or More Design Lanes Loaded:


DF = Number lanes/Number beams * MPF = 1/8 * 1.20 =

Page 14

0.150 Lanes

Vous aimerez peut-être aussi