INTRODUCTION
Background
Probable Construction Costs
Evaluation Criteria
Alternatives
Results
Design Costs
Individual Property Connection to Lateral Spur/Grinder Pumps Provided
Any required Electrical upgrades
Easement Acquisition
Pump Station property Acquisition
O&M Costs
EVALUATION CRITERIA
Capital Cost
Technical Feasibility
Life-Cycle Analysis
Owners Familiarity with System
Alternative A:
ALTERNATIVES
o Low Pressure Sewer (LPS) systems in Catlett and Calverton Sewer Areas
o 1 Pump station from Calverton to Midland
o Force main extending along Rt. 28 Catlett Road to Midland
Alternative B:
o LPS systems in Catlett and Calverton Sewer Areas
o 2 Pump stations and associated forcemains
o Catlett to Calverton
o Calverton to Midland
Alternative C:
o Gravity collection throughout Catlett and Calverton Sewer Areas
o 2 Pump stations and associated forcemains
o Catlett to Calverton
o Calverton to Midland
ALTERNATIVE A - CATLETT
ALTERNATIVE A - CALVERTON
ALTERNATIVE B - CATLETT
ALTERNATIVE B - CALVERTON
ALTERNATIVE C- CATLETT
ALTERNATIVE C - CALVERTON
MIDLAND
SUMMARY OF ALTERNATIVE A
Number of Grinder Pump Units:
113 Simplex
14 duplex
1 Quadplex
1 -4,820 Ft.
1 25,600 Ft.
2- 10,050 Ft.
2.5 -25,820 Ft.
3 9,100 Ft.
4 13,800 Ft.
SUMMARY OF ALTERNATIVE B
Number of Grinder Pump Units:
113 Simplex
14 duplex
1 Quadplex
1 -5,820 Ft.
1 20,850 Ft.
2- 12,100 Ft.
2.5 16,200 Ft.
3 10,000 Ft.
4 8,700 Ft.
Pump Stations: 2
Catlett Force Main to Calverton: 4- 17,228 Feet
Calverton Force Main to Midland: 4 or 6- 7,236 Feet
SUMMARY OF ALTERNATIVE C
8 Sewer ~ 56,000 Feet
4 ID Manholes ~ 175
Pump Stations: 2
Number of Grinder Pump Units: 40 Simplex
Individual Grinder Force Main:
1 -11,943 Ft.
2- 2,448 Ft.
53.8 gpm
4 inch
4 inch
Force Main
Size
Inches
2.4 ft/sec
1.2 ft/sec
Force Main
Velocity
Feet/Second
Pump Station
Design Capacity
Gallons Per
Minute
30,975 gpd
103 gpm
Average
Daily Design
Flow
Gallons per Day
Catlett
59,238 gpd
107,800 gpd
65,800 gpd
187 gpm
114 gpm
4 inch
4 inch
4.3 ft/sec
2.1 ft/sec
CHALLENGES
Coordinate with VDOT Plans for Rt. 28
Utilize VDOT Right of Way
Utility Crossings
Railroad Crossings
Stream Crossings at Bridges
Diabase Rock
Easement Acquisition
Technical
Feasibility
3
2
Life-Cycle
Costs
2
1
Owners
Familiarity
1
2
9
7
RESULTS
3
2
1
Total
Alternative A
Alternative B
1
Capital Costs
Alternative C
3 - Most Favorable
1 - Least Favorable