Vous êtes sur la page 1sur 10

Air Quality Monitoring

Aut
oma
tic
anal
yzer
s
Typi
cal
spe
cific
atio
ns
Rang
es

Trace level
Analyzers for
NO/NO2/NOx
(chemilumine
scence)

Analyzers for O3
(UV absorption)

Trace level
Analyzers for
SO2 (UV
fluorescence
)

Trace level
Analyzers for
CO (UV
absorption)

Tel
edy
ne
API
T20
0U

Thermo
Scientifi
c 42iTL

Tele
dyn
e
API
T40
0

Thermo
Scientific
49i

Tel
edy
ne
API
T10
0U

Thermo
Scienti
fic
43iTL

Tel
edy
ne
API
T30
0U

Thermo
Scientific
48iTL

min:
0-5
ppb
full
scal
e
max
: 02,00
0
ppb
full
scal
e
(sel
ecta
ble,
inde
pen

preset:
05/10/20/
50/100/2
00/500
and
1,000
ppb

min:
0100
ppb
full
scal
e
max:
0-10
ppm
full
scal
e
(sele
ctabl
e,
dual
rang
es)

preset: 00.05/0.1/0.2/0
.5/1/2/5/10/20
/50/100 and
200 ppm

min
: 05
ppb
full
scal
e
max
: 020,
000
ppb
full
scal
e
(sel
ecta
ble,
dual

preset:
010/20/5
0/100/2
00/500
and
1,000
ppb

min
: 0100
ppb
full
scal
e
max
: 0100
pp
m
full
scal
e
(sel
ecta
ble,
dual

preset: 01/5/10/20/
50/100/20
0/500 and
1,000
ppm

Meas
urem
ent
Units

Zero
Nois
e

Span
Nois
e

den
t
NO,
NO2,
NOx
ran
ges)
ppb,
g/
m3
(sel
ecta
ble)

<
25
ppt
(RM
S)
<
0.5
% of
rea
ding
(RM
S)
abo
ve 5
ppb

ran
ges)

ppb,
g/m3
(selectab
le)

ppb,
ppm
,
g/
m3,
mg/
m3
(sele
ctabl
e)

ppb, ppm,
g/m3, mg/m3
(selectable)

25 ppt
(RMS)

<
0.2
ppb
(RM
S)
<
0.5
% of
readi
ng
(RM
S)
abov
e
100
ppb

0.25 ppb
(RMS)

ppb
,
pp
m,
g/
m3,
mg/
m3
(sel
ecta
ble)
25
ppt
(RM
S)
0.5
%
of
rea
ding
(RM
S)
abo
ve 5
ppb

ran
ges)

ppb,
g/m3
(selecta
ble)

0.025
ppb
(RMS)

ppb
,
pp
m,
g/
m3,
mg/
m3
(sel
ecta
ble)
<
10
ppb
(RM
S)
<
0.5
%
of
rea
ding
(RM
S)
abo
ve
2.5

ppm,
mg/m3
(selectabl
e)

0.02 ppm
(RMS)

Lowe
r
Dete
ctabl
e
Limit
Zero
Drift

Span
Drift

Lag
Time

50
ppt

< 50 ppt
RMS

<
0.4
ppb

0.50 ppb

50
ppt

0.05
ppb

<
0.1
ppb
(24
hou
rs)
<
0.5
% of
rea
ding
(24
hou
rs)

negligibl
e (24
hours)

<
1.0
ppb
(24
hour
s)
<
1%
of
readi
ng
(24
hour
s)

< 1.0 ppb (24


hours)

<
0.2
ppb
(24
hou
rs)
<
0.5
%
of
full
scal
e
(24
hou
rs)

< 0.2
ppb per
day

10
seco
nds

10 seconds

20
sec
ond
s

1% full
scale (24
hours)

< 1% full
scale (per
month)

30
sec
ond
s

< 1%
full
scale

pp
m
<
20
ppb

<
20
ppb
(24
hou
rs)
<
0.5
%
of
rea
ding
abo
ve 5
pp
m
(24
hou
rs)
10
sec
ond
s

0.04 ppm

< 0.1
ppm (24
hours)

< 1% full
scale (24
hours)

Rise/
Fall
Time
(Res
pons
e
Time
)

<
50
sec
ond
s to
95%

Line
arity

Preci
sion

1%
of
full
scal
e
0.5
% of
rea
ding
abo
ve 5
ppb

Sam
ple

1,00
0

60
seconds
(10
second
averagin
g time)
90
seconds
(60
second
averagin
g time)
300
seconds
(300
second
averag.
time)
1% full
scale

1
liter/min

< 20
seco
nds
to
95%

20 seconds

<
140
sec
ond
s to
95
%

80
seconds

<
60
sec
ond
s to
95
%

60
seconds

1%
of
full
scal
e
<
0.5
% of
readi
ng
abov
e
100
ppb
800
cm3/

1% full scale

1%
of
full
scal
e
0.5
%
of
rea
ding

1% full
scale

1%
of
full
scal
e
0.5
%
of
rea
ding

1% full
scale

650
cm3

0.5
liters/mi

180
0

0.5
liters/min

1.0 ppb

1-3 liters/min

1.0 ppb

Flow
Rate

cm3/
min
10
%

Powe
r
Requ
irem
ents

100
V120
V,
220
V240
V,
50/
60
Hz
10V
,
5V,
1V,
0.1
V
(sel
ecta
ble)

Anal
og
Outp
ut
Rang
es

Reco
rder
Offse
t

10
%

min
10
%

100 VAC,
115 VAC,
220-240
VAC +/10% @
300W

100V
120
V,
220V
240
V,
50/6
0 Hz
10V,
5V,
1V,
0.1V
(sele
ctabl
e)

10
%

100 VAC, 115


VAC, 220-240
VAC +/-10%
@ 300W

/mi
n
10
%

100
V120
V,
220
V240
V,
50/
60
Hz
10V
,
5V,
1V,
0.1
V
(sel
ecta
ble)

100
VAC,
115
VAC,
220-240
VAC +/10% @
300W

10
%

cm3
/mi
n
10
%
100
V120
V,
220
V240
V,
50/
60
Hz
10V
,
5V,
1V,
0.1
V
(sel
ecta
ble)
10
%

100 VAC,
115 VAC,
220-240
VAC +/10% @
300W

inclu
ded
I/O

1x
Eth
ern
et
10/
100
Bas
e-T
2x
RS2
32
(30
0115,
200
bau
d)
2x
USB
devi
ce
port
s
8x
opt
oisol
ate
d
digit
al
out
puts

Outputs:
Selectabl
e
Voltage,
RS232/R
S485,
TCP/IP,
10
Status
Relays,
and
Power
Fail
Indicatio
n
Inputs:
16 x
digital
inputs

1x
Ethe
rnet
10/1
00
Base
-T
2x
RS2
32
(300
115,
200
baud
)
2x
USB
devi
ce
port
s
8x
opto
isola
ted
digit
al
outp
uts
6x
opto

Outputs:
Selectable
Voltage,
RS232/RS485,
TCP/IP, 10
Status Relays,
and Power Fail
Indication
Inputs:
16 x digital
inputs

1x
Eth
ern
et
10/
100
Bas
e-T
2x
RS2
32
(30
0115
,20
0
bau
d)
2x
USB
devi
ce
port
s
8x
opt
oisol
ate
d
digi
tal
out

Outputs:
Selectab
le
Voltage,
RS232/R
S485,
TCP/IP,
10
Status
Relays,
and
Power
Fail
Indicatio
n
Inputs:
16 x
digital
inputs

1x
Eth
ern
et
10/
100
Bas
e-T
2x
RS2
32
(30
0115
,20
0
bau
d)
2x
USB
devi
ce
port
s
8x
opt
oisol
ate
d
digi
tal
out

Outputs:
Selectable
Voltage,
RS232/RS
485,
TCP/IP, 10
Status
Relays,
and Power
Fail
Indication
Inputs:
16 x
digital
inputs

6x
opt
oisol
ate
d
digit
al
inpu
ts
4x
anal
og
out
puts
optio
nal
I/O

1x
USB
com
port
1x
RS4
85
8x
anal
og
inpu
ts
(010V
,
12bit)

isola
ted
digit
al
inpu
ts
4x
anal
og
outp
uts

Outputs:
6 x 0-20
or 4-20
mA
isolated
current
outputs
Inputs:
8 x 0-10
Vdc
analog
inputs

1x
USB
com
port
1x
RS4
85
8x
anal
og
inpu
ts
(010V,
12bit)
4x

Outputs:
6 x 0-20 or 420 mA
isolated
current
outputs
Inputs:
8 x 0-10 Vdc
analog inputs

puts
6x
opt
oisol
ate
d
digi
tal
inpu
ts
4x
anal
og
out
puts
1x
USB
com
port
1x
RS4
85
8x
anal
og
inpu
ts
(010V
,
12bit)

Outputs:
6 x 0-20
or 4-20
mA
isolated
current
outputs
Inputs:
8 x 0-10
Vdc
analog
inputs

puts
6x
opt
oisol
ate
d
digi
tal
inpu
ts
4x
anal
og
out
puts
1x
USB
com
port
1x
RS4
85
8x
anal
og
inpu
ts
(010V
,
12bit)

Outputs:
6 x 0-20
or 4-20
mA
isolated
current
outputs
Inputs:
8 x 0-10
Vdc
analog
inputs

Oper
ating
Temp
eratu
re
Rang
e

4x
digit
al
alar
m
out
puts
Mult
idro
p
RS2
32
3x
420
mA
curr
ent
out
puts
540
C
20 30
C
(wit
h
US
EPA
Equi
vale
ncy)

digit
al
alar
m
outp
uts
Multi
drop
RS2
32
3x
420m
A
curr
ent
outp
uts

1535C
performa
nce or
5- 40C
operatin
g

540C
(with
US
EPA
Appr
oval)

Performance
specifications
based on
operation
within 2030 C range
(per U.S. EPA
Guidelines).
Instrument
may be safely
operated over
the range of
0-45 C.

4x
digi
tal
alar
m
out
puts
Mult
idro
p
RS2
32
3x
420
mA
curr
ent
out
puts
540
C
(wit
h
US
EPA
Equi
vale
ncy)

Perform
ance
specific
ations
based
on
operatio
n within
20-30
C range
(per
U.S. EPA
Guidelin

4x
digi
tal
alar
m
out
puts
Mult
idro
p
RS2
32
3x
420
mA
curr
ent
out
puts
540
C
1040
C
(wit
h
US
EPA
Equi
vale
ncy)

Performan
ce
specificati
ons based
on
operation
within
20-30 C
range
(per U.S.
EPA
Guideline
s).

Dime
nsion
s
(Hx
WxD
)
Weig
ht

Certi
ficati
ons

178
x
432
x
597
mm
Anal
yzer
: 18
kg;
Exte
rnal
pu
mp:
9.5
kg
US
EPA:
RFN
A119
4099

219 x
425 x
584 mm

25 kg

178
x
432
x
597
mm
12.7
kg /
13.8
kg
with
IZS

219 x 425 x
584 mm

US
EPA
EQO
A099
2087

US EPA
Equivalent
Method:
EQOA-0880047
MCerts
Certified:

25 kg

178
x
432
x
597
mm
20.
5 kg

US
EPA:
EQS
A049
5100

es).
Instrum
ent may
be
safely
operate
d over
the
range of
0-45
C.
219 x
425 x
584 mm

21.8 kg

U.S. EPA
Equivale
nt
Method:
EQSA0486060

Instrumen
t may be
safely
operated
over the
range of
0-45 C.

178
x
432
x
597
mm
22.
7 kg

219 x 425
x 584 mm

US
EPA:
RFC
A109
3093

U.S. EPA
Designate
d Method
(RFCA0981-054)

25 kg

EU:
EN1
462
5
TV
Rhei
nlan
d
QAL
1
Certi
fied:
EN1
526
7
MCe
rts:
Sira
MC0
500
70/0
8
CNE
MC:

()

No.
201
5028
Repo
rt

MC070096/00
EN14626:
936/2120324
8/13 Report
NF Certificate:
05/01

Vous aimerez peut-être aussi