Vous êtes sur la page 1sur 13

TEXAS ROUND HOUSE

SHEETS
A0. COVER SHEET
A1. GENERAL NOTES
A2. ELEVATIONS
A3. FLOOR PLAN
A4. SECTIONS
A5. FOUNDATION PLAN & DETAIL
A6. ROOF PLAN & DETAIL
A7. INTERIOR ELEVATIONS
A8. SCHEDULES
E1. ELECTRICAL (BLANK)
P1. PLUMBING & MECHANICAL (BLANK)
3D1 EXTERIOR IMAGES
3D2 INTERIOR DOLL HOUSE IMAGE

DESIGNED BY: JAMES BRYAN


DRAFTED BY: THE small HOUSE CATALOG
DECEMBER 23, 2015

CONTACT:
TEL:
EMAIL:

PARCEL NO.:
SITE ADDRESS:
BUILDER:

THE small HOUSE CATALOG


PO BOX 434
Friday Harbor, WA 98250
www.thesmallhousecatalog.com
support@thesmallhousecatalog.com

DESIGN:
END USER AGREEMENT
1) THESE PLANS HAVE BEEN DESIGNED TO SATISFY GENERALLY ACCEPTED BUILDING
REQUIREMENTS. HOWEVER,THE SMALL HOUSE CATALOGCANNOT GUARANTEE
THAT THEY WILL BE APPROPRIATE FOR YOUR SPECIFIC CONDITIONS OR THAT THEY
WILL MEET ALL THE REQUIREMENTS OF YOUR LOCAL CODING AGENCY. IT IS THE
RESPONSIBILITY OF THE LICENSEE TO SEE THAT THEY DO. CONSULTATION WITH YOUR
BUILDER PRIOR TO SUBMISSION OF A PERMIT APPLICATION IS RECOMMENDED.

FLOOR AREA: 617.4 SQ FT


TAXABLE AREA: 617.4 SQ FT
ITEM

DESIGN STANDARDS:
INTERNATIONAL RESIDENTIAL CODE
ARCH D 24" X 36" BLACK & WHITE PRINTING

2) THE SMALL HOUSE CATALOG INCLUDING ANYONE WHO HAS BEEN INVOLVED
IN THE CREATION, PRODUCTION, OR DELIVERY OF THESE DOCUMENTS SHALL NOT
BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, OR INCIDENTAL DAMAGES.
3) THE LICENSEE IS GRANTED LICENSE TO BUILD ONE HOUSE PER PLAN. ADDITIONAL
PRINTS MAY BE INDEPENDENTLY COPIED, AS REQUIRED, TO BUILD YOUR HOUSE. ANY
CHANGES TO THESE PLANS MUST BE CONFIRMED BY A LICENSED STRUCTURAL
ENGINEER AND APPROVED BY YOUR LOCAL CODE ENFORCEMENT AGENCY.
4) ALL PLANS ARE PROTECTED BY FEDERAL COPYRIGHT LAWS. ANY USE OF THE
INFORMATION CONTAINED HEREIN BEYOND THE ONE-TIME USE AUTHORIZED BY A
PURCHASE OF PRINTS, OR ANY DUPLICATION, PUBLICATION, SALE OR DISTRIBUTION
OF ANY PART OF THESE PLANS WITHOUT THE PRIOR WRITTEN CONSENT OF THE
ORIGINAL DESIGNER REPRESENTS A VIOLATION OF FEDERAL LAWS SUBJECT TO THE
PRESCRIBED PENALTIES.
5) ANY USE OF THE PLANS, OR MODIFICATIONS OF THE PLANS, BY PURCHASERS,
BUILDERS OR OTHERS IS DONE AT THEIR OWN RISK. LICENSEE SHOULD HAVE THE
PLANS REVIEWED BY A LOCAL PROFESSIONAL ARCHITECT OR ENGINEER BEFORE THE
START OF CONSTRUCTION. THE INFORMATION CONTAINED WITHIN THE
CONSTRUCTION DOCUMENTS IS INTENDED TO DEPICT DESIGN AND BASIC
CONSTRUCTION DETAILING. IT IS THE BUILDER'S RESPONSIBILITY TO PROVIDE
STANDARD CONSTRUCTION DETAILS AND PRACTICES WHICH WILL RESULT IN A
STRUCTURALLY SOUND AND WEATHERPROOF FINISHED PRODUCT.

DISCLAIMER & CONSTRUCTION WARNINGS


1)THE SMALL HOUSE CATALOGHAS PREPARED THESE DOCUMENTS TO MEET
GENERALLY ACCEPTED PROFESSIONAL STANDARDS AND PRACTICES. HOWEVER, THEY
HAVE BEEN DESIGNED WITHOUT ANY KNOWLEDGE OF OR REFERENCE TO THE
LICENSEES SPECIFIC SITE OR GEOGRAPHICAL LOCATION.SPECIFIC SITE CONDITIONS
MAY VARY AND INCLUDE BUT ARE NOT LIMITED TO SUCH THINGS AS: SUCH AS
FROST DEPTH, SOIL BEARING CAPACITY, SEISMIC AND WIND ZONES, ETC.IN
ADDITION , LOCAL CODE REQUIREMENTS, INCLUDING SUCH LIFE-SAFET Y
REQUIREMENTS AS STAIR WIDTH, STAIR RISE AND RUN, EGRESS WINDOWS AND
SMOKE DETECTORS, ETC. MAY VARY.THE STRENGTH OF MATERIALS (E.G. LUMBER)
AVAILABLE MAY VARY.THEREFORE,SUPPLEMENTAL TO THESE DOCUMENTS, IT IS THE
LICENSEES RESPONSIBILITY TO CONSULT WITH HIS/HER CHOSEN BUILDER, LOCAL
BUILDING DEPARTMENT ANDA STRUCTURAL ENGINEER TO DETERMINE THAT THESE
DOCUMENTS MEET ALL CURRENT FEDERAL, STATE/PROVINCIAL AND LOCAL CODES,
ORDINANCES/BYLAWS AND REGULATIONS, ETC., AND ARE APPROPRIATE TO
SPECIFIC SITE CONDITIONS. COMPLIANCE WITH SUCH REQUIREMENTS SHALL TAKE
PRECEDENCE OVER THESE DOCUMENTS.
2) ANY USE OF THIS INFORMATION WITHOUT ADAPTATION TO CHANGES IN CODES,
STANDARDS, SITE CONDITIONS AND OTHER FACTORS IS AT THE LICENSEES SOLE
RISK.THE SMALL HOUSE CATALOGASSUMES NO RESPONSIBILITY FOR CHANGES
MADE TO THESE PLANS BY OTHERS AND MAKES NO WARRANTIES, EITHER EXPRESSED
OR IMPLIED, IN THE USE OF THESE PLANS. THE LICENSEE AGREES TO DEFEND AND
INDEMNIFYTHE SMALL HOUSE CATALOGFOR ALL CLAIMS, COSTS, LOSSES OR
DAMAGES RESULTING FROM THE USE OF THESE DOCUMENTS.
3) BEFORE STARTING CONSTRUCTION, IT IS THE BUILDERS RESPONSIBILITY TO CHECK
ALL DIMENSIONS AND DETAILS, AND VERIFY CONFORMANCE WITH GOVERNING
CODE REQUIREMENTS FOR THE GEOGRAPHIC AREA IN WHICH THE HOUSE IS TO BE
BUILT. ALL STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS SHALL ALSO
BE REVIEWED BEFORE CONSTRUCTION BEGINS. CODES GOVERN OVER DRAWINGS
AND DIMENSIONS GOVERN OVER SCALE. PLEASE NOTIFYTHE SMALL HOUSE
CATALOGOF DIMENSIONAL DISCREPANCIES.
4)THE SMALL HOUSE CATALOGHAS NOT BEEN ENGAGED FOR CONSTRUCTION
SUPERVISION OF ANY KIND AND ASSUMES NO RESPONSIBILITY TO ENSURE THAT
CONSTRUCTION CONFORMS TO THESE PLANS, NOR HAS ANY RESPONSIBILITY FOR
CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, PROCEDURES OR
SAFETY PRECAUTIONS IN CONNECTION WITH THE WORK.
5) THIS IS NOT A SALE OF ORIGINAL DOCUMENTS.THE SMALL HOUSE
CATALOGRETAINS OWNERSHIP OF ALL ORIGINAL DOCUMENTS AND ALL
SUBSEQUENT COPIES (REGARDLESS OF FORMAT).
6) THE LICENSEE IS GRANTED THE RIGHT TO MAKE COPIES AS NEEDED FOR THE
CONSTRUCTION OF ONE (1) BUILDING PER PLAN PURCHASE AND/OR FREE
DOWNLOAD.THE SMALL HOUSE CATALOGREQUESTS THAT YOU HONOR THIS
COPYRIGHT POLICY. ADDITIONAL RIGHTS CAN BE EASILY PURCHASED AT A
REASONABLE PRICE FROMTHE SMALL HOUSE CATALOGOFFICE.
7) TERMS AND CONDITIONS APPLY TO ALL PLANS.

1
2
3
4

DESIGN FACTORS:
FIRST FLOOR LOAD: 40 PSF LIVE / 10 PSF DEAD
SECOND FLOOR LOAD: 30 PSF LIVE / 10 PSF DEAD
ROOF LOAD: 20 PSF LIVE / 10 PSF DEAD (IRC TABLE R802.5.1(2)

SPECIAL DESIGN REQUIREMENTS:


ENGINEERING MAY BE REQUIRED IN SEISMIC & HIGH WIND
ZONES. CONTACT YOUR LOCAL BUILDING DEPARTMENT FOR
INFORMATION. IN ADDITION, SPECIAL BUILDING
REQUIREMENTS MAY BE RECOMMENDED OR REQUIRED IN
COASTAL, RIPARIAN OR FIRE REGIONS. CHECK YOUR LOCAL
CODE ENFORCEMENT AGENCY FOR DETAILS.

6) HOUSE PLANS ARE NON-REFUNDABLE.


7) TERMS AND CONDITIONS APPLY TO ALL PLANS.

TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS

CONSTRUCTION NOTES
FASTENERS: FOR ALL PRESERVATIVE-TREATED & FIRE- RETARDANT
TREATED: CONNECTORS SHALL BE TREATMENT RATED. FASTENERS SHALL
BE HOT- DIPPED ZINC-COATED GALVANIZED, STAINLESS STEEL, SILICON
BRONZE OR COPPER. FOLLOW IRC TABLE R602.3(1) FASTENER
SCHEDULE FOR STRUCTURAL MEMBERS.
SITE PREPARATION: A SURFACE DRAINAGE PATTERN SHOULD BE
ESTABLISHED WHICH WILL DRAIN THE ENTIRE AREA AND DIRECT WATER
AWAY FROM THE HOUSE. THE FINISHED GRADE WILL BE SLOPED AWAY
FROM THE FOUNDATION WALL OF THE HOUSE.
CONCRETE FOUNDATION: REMOVE ALL LOOSE & ORGANIC MATERIALS
& EXCAVATE FOR FOOTINGS & PADS AS PER PLANS. THE DISTANCE OF
THE FOOTING BASE TO THE FINISHED GRADE MUST BE NO LESS THAN
THE DEPTH OF LOCAL FROST PENETRATION. FOOTINGS MUST BE
ACCURATELY POSITIONED AND ROUGHLY LEVEL. FOOTINGS VARY IN
SIZE & DEPTH DEPENDING ON THE ALLOWABLE SOIL PRESSURE AND THE
LOAD. THE BOTTOM OF THE FOOTING IS ALWAYS PLACED ON
UNDISTURBED SOIL OR COMPACTED GRANULAR FILL WITH EACH RUN
LEVEL.

FRAMING: PRIOR TO SILL PLATE INSTALLATION, INSPECT CONCRETE


WORK CONDITION AND COMPARE ALL SITE DIMENSIONS WITH
FOUNDATION PLAN DIMENSIONS.
SILL ANCHOR: THE SILL PLATE SHOULD BE LEVELED CAREFULLY. IF THE
TOP OF THE FOUNDATION IS LEVEL, THE SILL PLATE MAY BE LAID ON
FOUNDATION WITH A CLOSED CELL FOAM GASKET OR OTHER AIRIMPERMEABLE MATERIAL IN BETWEEN, AND OF SAME WIDTH AS SILL
PLATE. SILL PLATES SHOULD BE PRESSURE TREATED 2x MATERIAL DF #2
OR BETTER & ANCHORED TO CONCRETE WALL WITH 5/8" ANCHOR
BOLTS EMBEDDED 7" MIN. IN CONCRETE & 2" MIN. ABOVE CONCRETE.
ANCHOR BOLT SHOULD BE PLACED 4'-0" o.c. MAX. APART AND 12"
FROM ENDS WITH TWO BOLTS MIN. PER SILL PLATE.

Ceiling joists to plate, toe nail


Ceiling joists not attached to parallel rafter, laps
over partitions, face nail
Collar tie rafter, face nail or 11/4" 20 gage ridge
strap

SPACING OF FASTENERS

3-8d (21/2" 0.113")

3-8d (21/2" 0.113")

3-10d

3-10d (3" 0.128")

Rafter to plate, toe nail

2-16d (31/2" 0.135")

Roof rafters to ridge, valley or hip rafters:


toe nail
face nail

4-16d (31/2" 0.135")

3-16d (31/2" 0.135")


Wall

Built-up corner studs

Built-up header, two pieces with 1/2" spacer

Continued header, two pieces

10

Continuous header to stud, toe nail

11
12

Double studs, face nail


Double top plates, face nail
Double top plates, minimum 24-inch offset of end
joints,
face nail in lapped area

13
14

Sole plate to joist or blocking, face nail

15

Sole plate to joist or blocking at braced wall panels

16

Stud to sole plate, toe nail

17

Top or sole plate to stud, end nail

18

Top plates, laps at corners and intersections, face


nail

19

1" brace to each stud and plate, face nail

20

1" 6" sheathing to each bearing, face nail

21

1" 8" sheathing to each bearing, face nail

22

Wider than 1" 8" sheathing to each bearing, face


nail

10d (3" 0.128")


16d (31/2" 0.135")
16d (31/2" 0.135")
4-8d (21/2" 0.113")
10d (3" 0.128")
10d (3" 0.128")

24" o.c.
16" o.c. along each edge

TABLE R602.3(1)-continued FASTENER SCHEDULE FOR STRUCTURAL MEMBERS


SPACING OF FASTENERS
Intermediate
Edges
supportsc, e
(inches)i
(inches)

DESCRIPTION OF BUILDING
ITEM
MATERIALS
DESCRIPTION OF FASTENERb, c, e
Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to
framing
6d common (20.113) nail (subfloor wall)
3 / -1 /
30
6
12g
8
2
8d common (21/20.131) nail (roof)f
19/ - 1
31
6
8d common nail (21/20.131)
12g
32
10d common (30.148) nail or
32
6
12
11/8 - 11/4
8d (21/20.131) deformed nail
Other wall sheathingh
33

1/ structural cellulosic
2
fiberboard sheathing

11/2 galvanized roofing nail, 7/16 crown or 1

34

25/ structural cellulosic


32
fiberboard sheathing

13/4 galvanized roofing nail, 7/16 crown or 1

16" o.c. along each edge

24" o.c.
24" o.c.

8-16d (31/2" 0.135")

35

1/ gypsum sheathingd
2

36

5/ gypsum sheathingd
8

16d (31/2" 0.135")


3-16d (31/2" 0.135")
3-8d (21/2" 0.113")
or
1
2-16d 3 /2" 0.135")
2-16d (31/2" 0.135")

16" o.c.

2-10d (3" 0.128")

16" o.c.

2-8d (21/2" 0.113")


2 staples 13/4"
2-8d (21/2" 0.113")
2 staples 13/4"
2-8d (21/2" 0.113")
3 staples 13/4"
3-8d (21/2" 0.113")
4 staples 13/4"

37

38

39

crown staple 16 ga., 11/4 long


crown staple 16 ga., 11/2 long
11/2 galvanized roofing nail; staple galvanized,
11/2 long; 11/4 screws, Type W or S
13/4 glavanized roofing nail; staple galvanized,
15/8 long; 15/8 screws, Type W or S

Wood structural panels, combination subfloor underlayment to framing


6d deformed (2 0.120) nail or
3/ and less
6
4
8d common (21/2 0.131) nail
8d common (21/2 0.131) nail or
7/ - 1
6
8
8d deformed (21/2 0.120) nail
10d common (3 0.148) nail or
6
11/8 - 11/4
8d deformed (21/2 0.120) nail

12

12

12

Floor
23

WATERPROOFING: CONCRETE WALLS BELOW GRADE SHOULD BE


WATERPROOFED WITH A NON-TOXIC ELASTOMERIC MATERIAL APPLIED
ON THE EXTERIOR SURFACE FROM THE FOOTINGS TO THE FINISHED
GRADE LINE, TO MAKE THE WALL WATERTIGHT AGAINST ORDINARY
SEEPAGE THAT MAY OCCUR.

DESCRIPTION OF BUILDING ELEMENTS


Roof
Blocking between joists or rafters to top plate, toe
nail

(continued)

NUMBER AND TYPE


OF FASTENERa, b, c

3-8d (21/2" 0.113")

Joist to sill or girder, toe nail

24

1" 6" subfloor or less to each joist, face nail

25

2" subfloor to joist or girder, blind and face nail

26

Rim joist to top plate, toe nail (roof applications


also)

27

2" planks (plank & beam - floor & roof)

28

Built-up girders and beams, 2-inch lumber layers

29

Ledger strip supporting joists or rafters

1 "
2-8d (2 /2 0.113")
3
2 staples 1 /4"
2-16d (31/2" 0.135")
8d (21/2" 0.113")
2-16d (31/2" 0.135")

6" o.c.
at each bearing

10d (3" 0.128")

Nail each layer as follows:


32" o.c. at top and bottom and
staggered. Two nails at ends
and at each splice.

3-16d (31/2" 0.135")

At each joist or rafter

FLOOR JOISTS: JOISTS ARE INSTALLED, LOCATED & SPACED ACCORDING


TO THE DESIGN. ANY JOISTS HAVING A SLIGHT BOW EDGEWISE
SHOULD BE PLACED WITH THE CROWN ON TOP. ALL JOISTS TO HAVE A
MINIMUM OF 1-1/2" BEARING AT SUPPORT. FLUSH FRAMED JOISTS TO
BE FASTENED TO BEAMS WITH FULLY NAILED JOIST HANGERS. ALL
FLOOR OPENINGS TO BE FRAMED WITH DOUBLE TRIMMER JOIST AND
DOUBLE HEADER JOIST. INSTALL DOUBLE JOIST OR SOLID BLOCKING
UNDER ALL FRAMED PARTITION WALLS. INSTALL BLOCKING BETWEEN
JOISTS TO TRANSFER CONCENTRATED LOADS TO BEARING BELOW.

8) MAILING ADDRESS:
THE SMALL HOUSE CATALOG

PRODUCT QUALITY:

FRIDAY HARBOR, WA 98250

CONSIDER SPECIAL ORDERING FORMALDEHYDE-FREE PLYWOOD, ZEROVOC, NON-TOXIC & NON-CARCINOGENIC PAINTS & STAINS, CAULKS,
SEALANTS & ADHESIVES RECOMMENDED.

TEL. (360) 207-4513.

BUGS & PESTS:

EMAIL: SUPPORT@THESMALLHOUSECATALOG.COM

NO BROAD SPECTRUM INSECTICIDES OR HERBICIDES TO BE APPLIED


BEFORE, DURING OR AFTER THE FOUNDATION WORK. APPLY TERMITE
SHIELDS ONLY, IF REQ'D. PROPERLY SCREEN VENTING & OPENINGS.

P.O. BOX 434

WEBSITE: WWW.THESMALLHOUSECATALOG.COM

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

GENERAL NOTES

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

01

MIN. U-FACTOR 0.30

OWNER REQUESTS
DECK (NOT SHOWN) BE
DESIGNED ON-SITE BY
BUILDER POSTCONSTRUCTION

19'-3 15/16"

METAL STANDING SEAM ROOFING


FOR SOLAR PANEL INSTALLATION

12-24-IN O/HANG

19'-1 5/16"

19'-1 5/16"

ADD TEMPORARY STAIRS


(NOT SHOWN)
& ADJUST TO GRADE

28'-0"

28'-0"

N
FRONT ELEVATION

REAR ELEVATION

scale: 1/4"=1'

A
02

scale: 1/4"=1'

B
02

HIGH WIND CHIMNEY CAP W/STORM COLLAR


SIZE PIPE ACCORDING TO FIREPLACE INSTRUCTIONS
SITE-BUILT CHASE; ALLOW PROPER CLEARANCE
FROM COMBUSTIBLE MATERIAL

ADD METAL STEP FLASHING @ CHIMNEY


12
2

19'-1 5/16"

19'-1 5/16"

28'-0"

28'-0"
ADD TEMPORARY STAIRS & RAILING, IF REQD.

RIGHT SIDE ELEVATION

LEFT SIDE ELEVATION


C
02

D
02

scale: 1/4"=1'

scale: 1/4"=1'

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

ELEVATIONS

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

02

A
04

ZERO-CLEARANCE FIREPLACE
INSTALL ACCORDING TO MANUFACTURERS
INSTALLATION INSTRUCTIONS
3'-7 7/8"

EGRESS:
1. ALL ROOMS TO BE USED FOR SLEEPING PURPOSES & BASEMENTS WITH
HABITABLE SPACE REQUIRE EMERGENCY & RESCUE OPENING COMPLYING WITH
IRC SEC R310.1.

-7
3'

ROUND WINDOW
O/CLOSET & PLANT SHELF

WINDOW REQUIREMENTS:

STORAGE

7/8
"

2'-7 3/16"

SD
CO

3'-7

4'-0"
"

LIVING ROOM

16"

7/8

9'-4 1/4"

13/

5'-9 1/2"

8"
7/
-7
3'

6"

1'-5

3'-7

/1

6"

CLOSET

1'-9 15/1
6"

15

1/1

12'-0"
1'-9 15/16"

3'-6 3/16"

3'-7 7/8"

150 CFM
FAN

ENTRY

6'-0"

BEDROOM

1'-9 15/16"

1'-4 1/2"

KITCHEN & DINING


1'-9 15/16"

1'-9 15/1
6"

3'-7 7/8"

7'-0"

1'-9 15/16"

SD
CO

11'-5 11/16"

5'-7 1/16

6'-6 1/4"

1'-9 15/1
6"

3'-7 7/8"

-9

6"

2. PROVIDE UL-2034 APPROVED CARBON MONOXIDE ALARMS OUTSIDE EACH


SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF EACH BEDROOM IN
ACCORDANCE WITH IRC R315.2 O

10'-1 15/16"

9'-4 5/16"

A
07

3'-7 7/8"

1. PROVIDE SMOKE DETECTORS IN ACCORDANCE WITH IRC R314.3.

1'

6"

2'-2

2. PROPANE & SOLID FUEL BURNING FIREPLACES TO BE INSTALLED ACCORDING


TO MANUFACTURER'S INSTRUCTIONS.

SMOKE DETECTORS & CARBON MONOXIDE ALARMS:

3'-6"

6"

/1

8"

/1

1. PROPANE & SOLID FUEL BURNING FIREPLACES INSTALLATION SHALL COMPLY


WITH IRC CHAP. 10

15

7/

15

MINIMUM FIREPLACE REQUIREMENTS:

-9

-7

8"

1. STAIRWAYS & STAIRWAY LANDINGS, HANDRAILS & ILLUMINATION SHALL


COMPLY WITH IRC SEC R311. GUARDS PER IRC SEC R312.

1'

6"

1. HABITABLE ROOMS PER IRC SEC R304 FOR FLOOR AREA.


STAIRS:

3'

-9

MINIMUM ROOM AREAS & CEILING HEIGHT:

VENTILATION RECOMMENDED

6"

4. SILL HEIGHT SHALL NOT BE MORE THAN 44" ABOVE THE FLOOR.
5. OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM
WITHOUT THE USE OF KEYS, TOOLS OR SPECIAL KNOWLEDGE.

16"

7/

/1

6"

16"

MIN. R-21 INSULATED WALL

1'

15

15/

15/

-7

3. MINIMUM 20" NET CLEAR OPENABLE WIDTH.

1'-9

7/8
"
1'-9

6"

-9

3'-7

/1

1'

/1

15/

15

2. MINIMUM 24" NET CLEAR OPENABLE HEIGHT.

15

-9

1'-9

3'

-9

1'

1
5/

-9
1'

/
15

6"

-9

1'

"

1'-9

1
15/

1'

1. MINIMUM 5.7 SQ. FT. NET CLEAR OPENABLE AREA, EXCEPT GRADE FLOOR
OPENINGS PERMIT MIN. 5 SQ. FT. OPENABLE AREA.

8
7/

/8"

16"

1'-9 1/2"

2. AT LEAST ONE DOOR SHALL MEET EGRESS REQ. IRC R311. THIS DOOR MUST
BE SIDE HINGED WITH MIN. 32" (813 MM) CLEAR WIDTH WHEN MEASURED B/T
THE FACE OF THE DOOR & THE STOP W/ DOOR AT 90 DEGREES (1.57 RAD.).
MIN. CLEAR HEIGHT OF DOOR MUST NOT BE < THAN 78" (1981 MM) MEASURED
FROM TOP OF THRESHOLD TO BOTTOM OF STOP.

7
3'-7

2-2X4 INSUL. HEADERS O/WINDOWS & DOORS

3'-7 7/8"

3'-6 15/16"

FLOOR PLAN NOTES:

1'-9 15/1
6"

3'

-7

7/

SHOWER

8"

-7
3'

WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING: GAS,


PROPANE OR OIL WATER HEATER WITH A MINIMUM EF OF 0.62
OR

3'-7

ELECTRIC WATER HEATER WITH A MINIMUM EF OF 0.93.


AND FOR BOTH CASES

3'-7
-7

80
CFM
FAN

3'

8"

3'-3 15/16"

7/

ELECTRIC TANKLESS
WATER HEATER
ECOSMART 27

7/8

"

WD

-7

EFFICIENT WATER HEATING

4'-0"

8"

BATHROOM

3'

FOLLOW IRC R602.10.3 & LOCAL CODE REQ'S.

1. WATER EFFICIENCY STANDARDS FOR PLUMBING FIXTURES SHALL BE MAX. 1.6


GAL PER FLUSH & 2.5 GAL PER MINUTE FOR SHOWER HEADS, LAVATORY
FAUCETS AND KITCHEN FAUCETS.

80
CFM
FAN

2'-5 1/16"

CLOSET

WALK-IN CLOSET

B
07

"

1'-9 15/16"

5'-7 1/2"

7/

CABINET

BRACED WALLS:

WATER EFFICIENCY:

4'-7"

3'-3"

7/8

BLOCKING:
1. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF FLOOR, CEILING &
ROOF SYSTEMS AS PER IRC SEC R502, R802, IBC SEC 2308.8.2 & R2308.10.6.

6'-6"

3'-7

1. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER SCHEDULE, TABLES R602.3


(1) THRU (5).

2'-4"

3'-5 7/8"

REF

1'-9 15/16"

2'-9 1/4"
1'-2 9/16"

FASTENER SCHEDULE:

2'-5 3/4"

13'-5"

7/8

7
3'-7

"
3'-7 7/8"

"
/8

IRC PRESCRIPTIVE SHEAR WALLS AS PER IRC 602.10.4 FOR CS-WSP, EXTERIOR WALLS.
MIN. 24 RETURN, EACH DIRECTION @ ALL CORNERS.
IRC 602.10.4.1: CS-WSP NAILING SCHEDULE: 6d NAILS @ 6" O.C. (EDGES) &
12" (INTERMEDIATE) & 1-" BLOCKING @ HORIZ. JOINTS

/8"

3'-7 7/8"

ALL SHOWER HEAD AND KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE
SHALL BE RATED AT 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL
BE RATED AT 1.0 GPM OR LESS.B TO QUALIFY TO CLAIM THIS CREDIT, THE
BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND
SHALL SPECIFY THE WATER HEATER EQUIPMENT TYPE AND THE MINIMUM
EQUIPMENT EFFICIENCY AND SHALL SPECIFY THE MAXIMUM FLOW RATES FOR
ALL SHOWER HEADS, KITCHEN SINK FAUCETS, AND OTHER LAVATORY FAUCETS.
28 DIA. FLOOR PLAN
A
03

scale: 1/2=1'

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

FLOOR PLAN

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

03

STANDING SEAM METAL


ROOFING UNDERLAYMENT
" CDX SHEATHING
ENGINEERED WOOD I-RAFTERS @ 16 O.C.
MIN. R-60 INSULATION, SPRAY-FOAM RECOMMENDED
WOOD PANELING (DRWALL MAY BE RQD TO MEET
FIRE RESISTANCE, CHECK LOCAL CODES)
ADD CEILING SUITABLE FOR SUPPORTING PLANTS
CHIMNEY TO BE INSTALLED ACCORDING TO
MANUFACTURERS INSTALLTION INSTRUCTIONS;
CONFIRM CLEARANCE REQS W/ MANUFACTURER
& VERIFY W/ LOCAL CODE

SOLAR ARRAY TO BE INSTALLED ACCORDING TO


MANUFACTURERS INSTALLTION INSTRUCTIONS; VERIFY
ROOF LOAD REQS FOR PANELS

BUILDING NOTES:

R1001.11 FIREPLACE CLEARANCE. ALL WOOD BEAMS, JOISTS, STUDS AND OTHER
COMBUSTIBLE MATERIAL SHALL HAVE A CLEARANCE OF NOT LESS THAN 2
INCHES (51 MM) FROM THE FRONT FACES AND SIDES OF MASONRY FIREPLACES
AND NOT LESS THAN 4 INCHES (102 MM) FROM THE BACK FACES OF MASONRY
FIREPLACES. THE AIR SPACE SHALL NOT BE FILLED, EXCEPT TO PROVIDE FIRE
BLOCKING IN ACCORDANCE WITH SECTION R1001.12.

ROOF SYSTEM:
STANDING SEAM METAL
ROOFING UNDERLAYMENT
" CDX SHEATHING
ENGINEERED WOOD I-RAFTERS @ 16 O.C., TYP.
MIN. R-60 INSULATION
" SHEETROCK OR T&G WOOD PANELING

12
2

8'-0"

SIDING: CORRUGATED METAL OR SHINGLES


HOUSEWRAP
1/2" CDX PLYWOOD SHEATHING
2X6 DF OR SPF #2 STUDS @ 16 O.C. (SEE WALL DETAILS)
2-2X4 HEADERS @ OPENINGS
CAULKING AT ALL STUD AND PLATE JOINTS
MINIMUM R-21 CAVITY INSULATION
CAULK & SEAL @ EXT. DOORS AND WINDOWS
INTERIOR SURFACE: WOOD PANELING OR 5/8" G.W.B.
INTERIOR LATEX PAINT

8'-0"

13'-10 1/4"

WALL SYSTEM:

SIDING: CORRUGATED METAL OR SHINGLES


" RAINSCREEN, OPT.
HOUSEWRAP
1/2" CDX PLYWOOD SHEATHING
2X6 DF OR SPF #2 STUDS @ 16 O.C. (SEE WALL DETAILS)
2-2X6 HEADERS @ OPENINGS
CAULKING AT ALL STUD AND PLATE JOINTS
MINIMUM R-21 CAVITY INSULATION
CAULK & SEAL @ EXT. DOORS AND WINDOWS
INTERIOR SURFACE: WOOD PANELING (DRYWALL MAY BE REQD TO
MEET FIRE CODE, CHECL LOCAL CODES)
INTERIOR LATEX PAINT

I-JOISTS @ 16-IN O.C. W/ MIN. R-30 INSUL.

MAIN FLOOR SYSTEM:

ADD METAL FLASHING OR CDX PLYWOOD


BELOW JOISTS FOR RODENT PROTECTION

WOOD, CORK OR SIMILAR FINISH FLOOR


1- STURD-I-FLOOR
PREMANUFACTURED I-JOIST SYSTEM @ 16 O.C. W.MIN. R-30 INSUL., TYP.
METAL FLASHING OR CDX PLYWOOD COVERING BELOW JOISTS FOR
MOISTURE & RODENT PROTECTION

CAST CONCRETE PIER FOUNDATION SYSTEM:

HOUSE CROSS SECTION


A
04

18 IN SONO-TUBES
BIGFOOT MODEL BF36 36-IN FOOTINGS
UNDISTURBED OR COMPACTD EARTH

scale: 1/4"=1'

SPRAY-FOAM SMALL SPACES


1- CDX TOP PLATE CUT TO FIT CURVATURE OF TOP LOWER PLAT

HEATING & A/C SYSTEM:


ZERO-CLEARANCE DIRECT-VENT NG, LPG OR WOOD FIREPLACE
AIR-CONDITIONER SYSTEM TBD BY HVAC PROFESSIONAL

VENTILATION SYSTEM:
EXHAUST FAN @ KITCHEN (150 CFM)
EXHAUST FAN BATHS & LAUNDRY (MIN. 80 CFM OR CONNECTED TO HRV)
MIN. 55 CFM HRV SYSTEM RECOMMENDED

DBL TOP PLATE


FASTEN SIMPSON STRONG-TIE HRS416Z

WALL SLOPE: 2:12


MIN. R-21 INSULATION

@ EACH BREAK IN TOP PLATE

EACH STUD MUST BE INDIVIDUALLY BEVELED @ TOP


INSULATE HEADERS W/ RIGID POLYISOCYANURATE

JUMBO-TEX OR SIMILAR

CDX BENDS AROUND


CURVATURE OF WALL;
FOLLOW IRC R602.3(1)
FASTENER SCHEDULE

CURVED WALL IS CREATED BY BUILDING


SMALL 15 ANGLED SEGMENTS.

WALL SECTION DETAILS


B
04

no scale

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

CROSS SECTIONS

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

04

ADD FILLER BLOCK B/T SISTERED I-JOISTS


26'-11 7/8"

GENERAL FOUNDATION NOTES:

SOLID 2X BLOCKING B/T ALL JOISTS

ATTACH SHEATHING REINFORCEMENTS


TO JOIST TOP & BOTTOM FLANGES
(MIN. 3X CANTILEVER LENGTH)

CDX SHEATHING
1. THE SILL PLATE SHOULD BE LEVELED CAREFULLY. IF THE
TOP OF THE FOUNDATION IS LEVEL, THE SILL PLATE MAY
BE LAID ON FOUNDATION WITH A CLOSED CELL FOAM
GASKET OR OTHER AIR-IMPERMEABLE MATERIAL IN
BETWEEN, AND OF SAME WIDTH AS SILL PLATE.

45

AREA RESERVED FOR PLUMBING SUPPLY


& WASTE LINES

5/1

6"

10'

5/1

-3 1

-3 1

8. MIN. 4" SLAB O/ POLY LAYER.

26'-11 7/8"

24F-1.7E (V4) SOUTHERN PINE


GLULAM 3- X 11-

B
05

6"

11'-11/16"

5/1

(2) 4X12 PT HEADER

-3 1

BIGFOOT FOOTING FORM


& SONOTUBE

ADD 2X BLOCKING B/T JOISTS

10'

6"

FIRE-RETARDANT
CONNECTORS &
STEEL, SILICON
SEC R317.

5/1

7. FOR ALL PRESSURE PRESERVATIVE &


TREATED WOOD USE TREATMENT RATED
HOT-DIPPED GALVANIZED, STAINLESS
BRONZE OR COPPER FASTENERS PER IRC

11'-11/16"

-3 1

6. LUMBER SHALL BE PROTECTED AGAINST ROT & DECAY


PER IRC SEC R317.

BEVEL JOISTS, OPT.

6"

4-0

10'

5. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF


FLOOR, CEILING & ROOF SYSTEMS PER IRC SEC'S R502 &
R802 & IBC SEC'S 2308.8.2 & 2308.10.6.

5/1

10'

4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER


SCHEDULE, TABLES R602.3 (1) THRU (5).

-3 1

67

3. PROVIDE APPROVED ANCHORAGE OF BEAMS OR


GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.

10'

6"

6"

2. SILL PLATES SHOULD BE PRESSURE TREATED 2X


MATERIAL DF #2 OR BETTER & ANCHORED TO CONCRETE
WALL WITH 5/8" ANCHOR BOLTS EMBEDDED 7" MIN. IN
CONCRETE & 2" MIN. ABOVE CONCRETE. ANCHOR BOLT
SHOULD BE PLACED 4'-0" O.C. MAX. APART AND 12"
FROM ENDS WITH TWO BOLTS MIN. PER SILL PLATE.

0'-3

1
15/

10'

-3 1

5/1

6"

10'

-3

1
15/

6"

9. PROVIDE CRAWL SPACE ACCESS DOOR PER IRC 408.4


FOR CRAWL SPACES, WHERE APPLICABLE.

SOLID 2X BLOCKING
B/T ALL JOISTS

10. PROVIDE VENTILATION PER IRC R408.1 (1 SQ FT


OPENING PER 150 SQ FT FLOOR SPACE), WHERE
APPLICABLE.

28-0"

11. R E F E R TO M A N U FAC T U R E R ' S I N S TA L L AT I O N


INSTRUCTIONS FOR ENGINEERED JOISTS.
12. FOLLOW IRC R1001 FOR MASONRY FIREPLACES &
CONSULT W/ YOUR MASON TO FINALIZE THE DESIGN.

FLOOR FRAMING PLAN


PIER FOUNDATION PLAN
A
05

C
05

scale: 1/4"=1'

scale: 1/4"=1'

TABLE R402.2 MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF CONCRETE

TYPE OR LOCATION OF CONCRETE


CONSTRUCTION

GENERAL FRAMING NOTES:


1. NON-ENGINEERED JOISTS TO BE NO. 2 GRADE OR
BETTER
2.PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
3. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S 502 & R802, IBC SEC'S 2308.8.2 & R2308.10.6.

INTERSECTING P.T. 8X8S

THREADED GALV. ROD EMBEDDED MIN. 12-IN


GALV. NUT W/ GALV. NUT

THREADED GALV. ROD EMBEDDED MIN. 12-IN


GALV. NUT W/ GALV. NUT

Negligible

Moderate

Severe

Basement walls, foundations and other


concrete not exposed to the weather

2,500

2,500

2,500c

Basement slabs and interior slabs on


grade, except garage floor slabs

2,500

2,500

2,500c

Basement walls, foundation walls,


exterior walls and other vertical
concrete work exposed to the weather

2,500

3,000d

3,000d

Porches, carport slabs and steps


exposed to the weather, and garage
floor slabs

2,500

3,000d, e, f

3,500d, e,
f

CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE


STRENGTH OF FC, AS SHOWN IN TABLE R402.2. CONCRETE
SUBJECT TO MODERATE OR SEVERE WEATHERING AS INDICATED
IN TABLE R301.2(1) SHALL BE AIR ENTRAINED AS SPECIFIED IN
TABLE R402.2. THE MAXIMUM WEIGHT OF FLY ASH, OTHER
POZZOLANS, SILICA FUME, SLAG OR BLENDED CEMENTS THAT IS
INCLUDED IN CONCRETE MIXTURES FOR GARAGE FLOOR SLABS
AND FOR EXTERIOR PORCHES, CARPORT SLABS AND STEPS THAT
WILL BE EXPOSED TO DEICING CHEMICALS SHALL NOT EXCEED
THE PERCENTAGES OF THE TOTAL WEIGHT OF CEMENTITIOUS
MATERIALS SPECIFIED IN SECTION 4.2.3 OF ACI 318. MATERIALS
USED TO PRODUCE CONCRETE AND TESTING THEREOF SHALL
COMPLY WITH THE APPLICABLE STANDARDS LISTED IN CHAPTER 3
OF ACI 318 OR ACI 332.

4-#4 VERT. REBAR

5. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER


SCHEDULE, TABLES R602.3 (1) THRU (5).

7. FOLLOW IRC TABLE R502.3.1(1) FOR JOIST SPANS OR


MANUFACTURERS SPECS FOR ENGINEERED JOISTS.

Weathering Potential b

R402.2 CONCRETE.

18-IN DIAMETER SONO-TUBE FORM


3000 PSI CONCRETE

4. PROVIDE APPROVED ANCHORAGE OF BEAMS OR


GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.

6. ALL JOISTS DOUBLED @ FLOOR OPENINGS.

MINIMUM SPECIFIED COMPRESSIVE


STRENGTHa (fc)

BIGFOOT MODEL BF36 IS 36 IN. (91.44 CM) IN DIAMETER AT THE


BASE, WHICH WILL ACCOMMODATE THE 12 IN (30.48CM) 14 IN
(35.56CM) 16 IN (40.64CM) AND 18 IN (45.72CM). THE BF36 IS
ALSO AVAILABLE IN METRIC, WHICH WILL ACCOMMODATE
CONSTRUCTION TUBES (300MM-450MM).

BIGFOOT BF36 FOOTING FORM


UNDISTURBED OR COMPACTED EARTH

3-0
PIER FOOTING DETAIL
B
05

scale: 1/2=1'

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

FOUNDATION PLAN & DETAIL

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

05

FASCIA
WALL BELOW
ATTACH SHEATHING REINFORCEMENTS
TO JOIST TOP & BOTTOM FLANGES
(MIN. 3X CANTILEVER LENGTH)

ROOF FRAMING NOTES:

SOLID 2X BLOCKING B/T RAFTERS

12-24-IN O/HANG

2. POSITIVE CONNECTION & TRANSFER OF LOAD FROM


ROOF TO LOAD SUPPORTING ELEMENTS REQ'D.
3. PROVIDE ANCHORAGE OF BEAMS OR GIRDERS TO
POSTS PER IRC SEC'S R407.3, R502.9 & R802.11
4. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER
SCHEDULE, IRC TABLES R602.3 (1) THRU (5).
5. SOLID BLOCKING REQ'D @ ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S R502 & R802.
6. ATTIC VENTILATION PER IRC SEC R806.

CL
WINDOW
4'-4 3/16"

GENERAL FRAMING NOTES:


1. JOISTS TO BE NO. 2 GRADE OR BETTER
2.PROVIDE APPROVED ANCHORAGE OF BEAMS OR
GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.
3. SOLID BLOCKING REQ'D AT ALL BEARING POINTS OF
FLOOR, CEILING & ROOF SYSTEMS ACCORDING TO IRC
SEC'S 502 & R802, IBC SEC'S 2308.8.2 & R2308.10.6.

3'-6 1/8"

4. PROVIDE APPROVED ANCHORAGE OF BEAMS OR


GIRDERS TO POSTS PER IRC SEC'S R407.3, R502.9 &
R802.11.

ADD STRONG-TIE RAFTER CLIPS

CL
WINDOW
4'-4 3/16"

PREMANUFACTURERD I-RAFTERS @ 16 O.C. W/ MIN. R-60 INSULATION

1. NUMBER OF JACK STUDS FOR ALL GIRDER & HEADER


SPANS PER IRC TABLE R502.5 (1) & (2) - FOOTNOTE 'D'.

3'-6 1/8"

ROOF PLAN
A
06

scale: 1/4"=1'

5. THIS STRUCTURE TO COMPLY WITH MIN. FASTENER


SCHEDULE, TABLES R602.3 (1) THRU (5).
6. ALL JOISTS DOUBLED @ FLOOR OPENINGS.
7. FOLLOW IRC TABLE R502.3.1(1) FOR JOIST SPANS.

BLOCK ALL RAFTERS W/ I-JOIST OR


LSL FRIEZE BLOCKING

BLOCK ALL RAFTERS W/ I-JOIST OR


LSL FRIEZE BLOCKING

I-RAFTER

I-RAFTER

ADD CLIP

ADD WEB STIFFENER PER MANUFACTURER'S SPECS

BEVELED WOOD FILLER OR VARIABLE


SLOPE METAL CONNECTOR

DBL TOP PLATE OR SINGLE PLATE W/


COORDINATED RAFTERS & STUDS

I-RAFTER CONNECTION AT
TOP PLATE

I-RAFTER CONNECTION AT
BEARING PLATE
B
06

C
06

scale: none

scale: none

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

ROOF FRAMING PLAN & DETAILS

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

06

STANDARD 36 REF.
INT. WALLS CAN BE ADJ. TO ANY HEIGHT;
CONSULT W/OWNER

STANDARD 30-IN
RANGE & HOOD

4 1/2"
2'-7"

6'-6 1/4"

4 1/2"

5'-7 1/16"

3'-7 1/16"

3'-0"

3'-0"

2'-0"

8'-0"

1'-6"

1'-6"

2'-0"

3'-0"

5'-7 1/2"

WRAPAROUND BAR;
PLUMBING OPT.

2'-0"

2'-0"

2'-7/8"

4'-0"

2'-5 3/8"

4'-6 1/4"

1'-4"

2'-7"
4 1/2"

2'-6"

1-0

KITCHEN VIEWS
A
07

scale: 1/2"=1'

REMEMBER: EXTERIOR WALLS ARE CURVED

6'-8"

STANDARD SINK & TOILET

2'-6"

4'-0"

BATHROOM VIEW
B
07

scale: 1/2 = 1

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

INTERIOR VIEWS

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

07

EXT. WINDOWS & DOORS


scale: 1/4"=1'

A
08

WINDOW SCHEDULE
SIZE

STYLE

NO.

2-6 X 5-0

DBL HUNG OR CASEMENT

2-6 X 4-0

DBL HUNG OR CASEMENT

2-6 X 4-0

VENTING SKYLIGHT

24 ROUND

ROUND (VENTING, OPT.)

LIVING ROOM

DOOR SCHEDULE
SIZE

STYLE

NO.

2-4 X 6-8

BEDROOM EXTERIOR W/GLASS

2-6 X 6-8

EXT. STORAGE

3-0 X 6-8

ENTRYBIFOLDING
(EGRESS)
TRIPLE

2'-6" X 6'-8"

INTERIOR CLOSET

2'-6" X 6'-8"

BATHROOM POCKET

1-8 X 6'-8"

LINEN POCKET

2'-6" X 6'-8"

BI-FOLD LAUNDRY

STORAGE
CLOSET
4

ENTRY

WINDOW & DOOR


SECHDULES
C
09

BEDROOM

scale: 1/4"=1'

KITCHEN & DINING

REF

CLOSET

WALK-IN CLOSET

BATHROOM
6

WD
SHOWER
ALL DOOR LOCATIONS
C
08

TEXAS ROUND HOUSE

REVISIONS

scale:1/2=1'

MM/DD/YY

WINDOW & DOOR SCHEDULES

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

08

COMMON RESIDENTIAL ELECTRICAL SYMBOLS

ELECTRICAL NOTES:

DUPLEX POWER RECEPTACLE


DUPLEX POWER RECEPTACLE ON
DEDICATED CIRCUIT

BEFORE YOU BEGIN:

D
GFI

GFIC/WP

DUPLEX POWER RECEPTACLE W/


GROUND FAULT INTERRUPTOR
CIRCUIT (WP = WEATHERPROOF)
240

IF YOU INTEND TO DO YOUR OWN ELECTRICAL WORK, IT IS


GOOD PRACTICE TO HIRE A CERTIFIED ELECTRICIAN TO
REVIEW THE PLAN BEFORE YOU BEGIN WORK, MAKE
NECESSARY CHANGES & CORRECTIONS, LOCATE YOUR
PANEL BOX & METER, SPECIFY WIRE GAUGES, AND REVIEW
YOUR WORK PRIOR TO INSPECTION.

240 OUTLET

D-240

240 OUTLET ON DEDICATED CIRCUIT

OUTLETS:

SWITCH

$3

THREE-WAY SWITCH

1. ALL KITCHEN, BATHROOM, BASEMENT AND CRAWL SPACE


OUTLETS TO BE GFCI.

INT. WALL SCONCE

2. EXTERIOR OUTLETS TO BE WEATHER PROOF GFCI.

INT. CEILING LIGHT

3. STANDARD OUTLETS TO BE TAMPER RESISTANT.


4. AFCI REQ'D ON ALL CIRCUITS SERVING LIVING AREAS.

LIVING ROOM

WATER HEATER:

STORAGE

1. A 4-6 GPM ELECTRIC ON-DEMAND W.H. IS TYP. SUFFICIENT


EVEN IN NORTHERN CLIMATES TO ADEQUATELY SUPPLY THE
BATHTUB.

CLOSET

EXT. WALL SCONCE

W.R.

EXT. CEILING LIGHT

W.R.

CHANDELIER

SD
CO

SMOKE DETETCTOR

2. FOR ON-DEMAND PROPANE OR GAS W.H., PROVIDE


VENTILATION.

SD

CARBON MONOXIDE DETECTOR

CO

TELEPHONE OUTLET

LAUNDRY ROOMS:

DATA/CAT-6
TELEPHONE/CAT-6

1. 110 CFM REQ'D IN LAUNDRY ROOM.


150 CFM
FAN

2. GFI OUTLETS

ENTRY

BATHROOMS:

CABLE TV OUTLET

TV

GARBAGE DISPOSAL

GD

ELECTRICAL SERVICE PANEL


SD
CO

1. GFI OUTLETS ON DEDICATED CIRCUIT.

JUNCTION BOX (WITH WHIP)

BEDROOM

2. MIN. 110 CFM EXHAUST FAN REQ'D.

DOOR BELL

A
07

KITCHEN:

ESP

WH

WATER HEATER

KITCHEN & DINING

1. MIN. TWO OUTLET CIRCUITS.


2. GIF OUTLETS REQ'D.
3. NON-GFI REFRIGERATOR OUTLET.
4. 150 CFM EXHAUST FAN O/ RANGE.

REF

PORCHES:

4'-8"

1. MIN. ONE WP-GFI PER PORCH.


2. WP LIGHTS

2. ALL SLEEPING AREAS TO HAVE INDIVIDUAL SMOKE


DETECTORS.
3. PHOTOELECTRIC (NON-IONIZING) SMOKE DETECTORS ARE
RECOMMENDED.

CLOSET
ELECTRIC TANKLESS
WATER HEATER
ECOSMART 27

80
CFM
FAN

BATHROOM

WD
3'-3 15/16"

SMOKE DETECTORS:
1. EACH FLOOR (INCLUDING BASEMENT) TO HAVE A SMOKE
DETECTOR.

WALK-IN CLOSET

B
07

SHOWER

80
CFM
FAN

4. CO2 DETECTORS REQ'D WHERE SOLID FUEL HEATING IS TO


BE USED.
5. SMOKE AND CO2 DETECTORS TO BE WIRED ON SEPARATE
CIRCUITS.

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

ELECTRICAL PLAN (INTENTIONALLY BLANK)

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

A
E

09
1

GENERAL PLUMBING NOTES:

3'-6"

THIS SCALED SHEET IS FOR AIDING YOU AND YOUR PLUMBER IN


LAYING OUT THE PLUMBING SYSTEM FOR YOUR HOUSE.

VENTILATION RECOMMENDED

GENERAL INFORMATION ONLY. VERIFY WITH APPLICABLE


PLUMBING CODE (TYP. UPC), LOCAL CODE ENFORCEMENT, AND
MANUFACTURERS' RECOMMENDATIONS.

DRAIN, WASTE & VENT (DWV):

LIVING ROOM

1. KITCHEN SINKS: DWV MIN. 2" DRAIN & 1 1/2" VENT.

STORAGE

2.BATHROOM SINKS: DWV MIN. 1 1/4 DRAIN & VENT.


3. BATHTUBS: MIN. 2" DRAIN & 1 1/2" VENT.

CLOSET

SD
CO

4. SHOWERS: MIN. 1 1/2" DRAIN & VENT.


5. INCOMING WATER SUPPLY LINE: TYP. 3/4" - 1"
6. PRIMARY WATER SUPPLY LINE: TYP. 3/4"
7. INTERIOR WATER SUPPLY LINES: TYP. 1/2"

150 CFM
FAN

ENTRY

8. MAIN DRAIN LINE: TYP. 3"

SD
CO

9. MAIN STACK VENT: TYP. EQUAL OR > THAN MAIN DWV LINE.

BEDROOM

SUPPLY LINES (PEX OR COPPER, TYP.):

A
07

1. INCOMING SUPPLY LINE FROM STREET OR WELL: 1"


POLYPROPYLENE, COPPER OR PEX

KITCHEN & DINING

2. MAIN HOUSE LINE (ROOM TO ROOM): 3/4" - 1'


3. BATHROOM SINK: 1/2"
4. TOILET: 3/8"
5. BATHTUB/SHOWER: 1/2"

REF

6. KITCHEN SINK: 1/2"


7. WATER HEATER: 3/4"

CABINET

8. WASHING MACHINE: 3/4"


8. SPIGOTS: 1/2" - 3/4"

CLOSET

80
CFM
FAN

BATHROOM

WD
3'-3 15/16"

ELECTRIC TANKLESS
WATER HEATER
ECOSMART 27

WALK-IN CLOSET

B
07

SHOWER

80
CFM
FAN

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

PLUMBING & HVAC PLAN SHEET (INTENTIONALLY BLANK)

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

A
P

10
1

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

3D ISOMETRIC VIEWS

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

3D
A 11
1

REVISIONS

MM/DD/YY

TEXAS ROUND HOUSE

_ _ /_ _ /_ _ ...

_ _ /_ _ /_ _ ...

REMARKS

3D
A 12
2