Vous êtes sur la page 1sur 8

Customer : MHK

Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

** ON A/C ALL

24-67 - REFUELING ON BATTERY


24-67-00 - REFUELING ON BATTERY
24-67-00 PB 001 CONF 00 - REFUELING ON BATTERY - DESCRIPTION AND OPERATION
1. General
The refuelling electrical network consists of the ESS FUEL BUS (501PP) and the MAIN FUEL BUS (502PP).
This network is normally supplied by the aircraft network.
On ground, in case of unavailability of the electrical ground power unit, the batteries may be used as a power
source.
2. Component Location
(Ref. Fig. Refuelling on Battery - Component Location SHEET 1)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 1 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

A
715VU

2PR
1PR

FR18
FR16A
811

F_MM_246700_0_ABM0_01_00

Figure 24-67-00-12150-00-A / SHEET 1/1 - Refuelling on Battery - Component Location


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 2 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

(Ref. Fig. Refuel/Defuel Control Panel (Refuelling on Battery) - Component Location)

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 3 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

FR53.2

FR53.8

198AT
198EB

198HB
198BB
198GB
198DB
REFUEL/DEFUEL
CONTROL PANEL

F_MM_246700_0_AAM0_01_00

Figure 24-67-00-12200-00-A / SHEET 1/2 - Refuel/Defuel


Control Panel (Refuelling on Battery) - Component Location
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 4 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

L OUTER TK

L INNER TK

CTR TK

TRIM TK

R INNER TK

R OUTER TK

OVERFLOW
TT

HI LEVEL
TEST

INC

TRANSF.VALVE
CLOSED

L INR

CENTRE

L OUTER

R INR

X 1000
0 CKPT
0 END

R OUTER

TRIM

LOAD

PRESELECTED

DEC

ACTUAL

OPEN

REFUEL-DEFUEL-VALVES
L OUTER TK

REFUEL
OFF
DEFUEL

OPEN
NORM
SHUT

L INNER TK

OPEN
NORM
SHUT

CTR TK

OPEN
NORM
SHUT

TRIM TK

OPEN
NORM
SHUT

R INNER TK

OPEN
NORM
SHUT

APU EMERS

PWR
SUPPLY

MODE SELECT
R OUTER TK

NORM

OPEN
NORM
SHUT

SHUT
DOWN

BAT

990VU1
6PR

F_MM_246700_0_AAM0_02_00

Figure 24-67-00-12200-00-A / SHEET 2/2 - Refuel/Defuel


Control Panel (Refuelling on Battery) - Component Location
** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 5 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

FIN

FUNCTIONAL DESIGNATION

1PR
CNTOR - REFUEL ON BAT/NORM
2PR
RELAY-REFLNG BUS 501PP CTL
6PR
SW-PWR SUPPLY
3. System Description
(Ref. Fig. Refuelling on Battery - Schematic SHEET 1)

PANEL

715VU
715VU
990VU

ZO
NE

ACCESS
DOOR

120
120
198

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

ATA REF

24-67-00
24-67-00
24-67-00

Page 6 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL

1PX - CNTR
DC SVCE BUS
GND SPLY
8PR
601PP
28VDC
SVCE BUS

10PR
702PP
28VDC
HOT BUS

4PR
2PB2
BAT 2

9PR

3PR
6PP
28VDC

7PR
4PP
28VDC

2PB1
BAT 1

5PR

2PR - RLY
REFUELING BUS
501PP CTL

1PR - RLY
REFUEL ON
BAT/NORM

NORM
BAT

6PR - SW
REFUEL ON BAT

28VDC

28VDC

ESS FUEL BUS

MAIN FUEL BUS

501PP

502PP

1PN - CNTR
DC SVCE BUS
NORM SPLY

OPEN

SHUT
4QU - MSW
REFUEL DOOR POS

24-67 - REFUELING ON BATTERY

F_MM_246700_0_ADN0_01_00

Figure 24-67-00-13350-00-B / SHEET 1/1 - Refuelling on Battery - Schematic


** ON A/C ALL
Print Date: October 31, 2016
AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 7 of 8

Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016

Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY

The busbars 501PP and 502PP may be supplied from three different sources:
in normal configuration when all the electrical network is supplied (either by the main generator, or the APU
generator or the external power unit) and whatever the status of the refuel door position switch :
. the busbar 501PP is supplied by the busbar 4PP and the busbar 502PP by the busbar 6PP,
in ground service configuration with the refuel door position switch open:
. the busbar 501PP and 502PP are only supplied by the busbar 6PP,
in battery only configuration with the refuel door position switch open and the REFUEL ON BAT switch (6PR)
in BAT position:
. the busbar 501PP is supplied by the battery 1 and the busbar 502PP is supplied by the battery 2,
. in any other configuration the busbars 501PP and 502PP are not supplied.
Figure 24-67-00-12150-00-A / SHEET 1/1 - Refuelling on Battery - Component Location
Figure 24-67-00-12200-00-A / SHEET 1/2 - Refuel/Defuel Control Panel (Refuelling on Battery) - Component
Location
Figure 24-67-00-12200-00-A / SHEET 2/2 - Refuel/Defuel Control Panel (Refuelling on Battery) - Component
Location
Figure 24-67-00-13350-00-B / SHEET 1/1 - Refuelling on Battery - Schematic

End of document

Print Date: October 31, 2016


AIRBUS S.A.S. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.

Page 8 of 8

Vous aimerez peut-être aussi