24-67 - REFUELING ON BATTERY
** ON A/C ALL
Page 1 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
A
715VU
2PR
1PR
FR18
FR16A
811
F_MM_246700_0_ABM0_01_00
Page 2 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
Page 3 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
FR53.2
FR53.8
198AT
198EB
198HB
198BB
198GB
198DB
REFUEL/DEFUEL
CONTROL PANEL
F_MM_246700_0_AAM0_01_00
Page 4 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
L OUTER TK
L INNER TK
CTR TK
TRIM TK
R INNER TK
R OUTER TK
OVERFLOW
TT
HI LEVEL
TEST
INC
TRANSF.VALVE
CLOSED
L INR
CENTRE
L OUTER
R INR
X 1000
0 CKPT
0 END
R OUTER
TRIM
LOAD
PRESELECTED
DEC
ACTUAL
OPEN
REFUEL-DEFUEL-VALVES
L OUTER TK
REFUEL
OFF
DEFUEL
OPEN
NORM
SHUT
L INNER TK
OPEN
NORM
SHUT
CTR TK
OPEN
NORM
SHUT
TRIM TK
OPEN
NORM
SHUT
R INNER TK
OPEN
NORM
SHUT
APU EMERS
PWR
SUPPLY
MODE SELECT
R OUTER TK
NORM
OPEN
NORM
SHUT
SHUT
DOWN
BAT
990VU1
6PR
F_MM_246700_0_AAM0_02_00
Page 5 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
FIN
FUNCTIONAL DESIGNATION
1PR
CNTOR - REFUEL ON BAT/NORM
2PR
RELAY-REFLNG BUS 501PP CTL
6PR
SW-PWR SUPPLY
3. System Description
(Ref. Fig. Refuelling on Battery - Schematic SHEET 1)
PANEL
715VU
715VU
990VU
ZO
NE
ACCESS
DOOR
120
120
198
ATA REF
24-67-00
24-67-00
24-67-00
Page 6 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
1PX - CNTR
DC SVCE BUS
GND SPLY
8PR
601PP
28VDC
SVCE BUS
10PR
702PP
28VDC
HOT BUS
4PR
2PB2
BAT 2
9PR
3PR
6PP
28VDC
7PR
4PP
28VDC
2PB1
BAT 1
5PR
2PR - RLY
REFUELING BUS
501PP CTL
1PR - RLY
REFUEL ON
BAT/NORM
NORM
BAT
6PR - SW
REFUEL ON BAT
28VDC
28VDC
501PP
502PP
1PN - CNTR
DC SVCE BUS
NORM SPLY
OPEN
SHUT
4QU - MSW
REFUEL DOOR POS
F_MM_246700_0_ADN0_01_00
Page 7 of 8
Customer : MHK
Type : A340
Rev. Date : Jul 01, 2016
Manual : AMM
Selected applicability : ALL
24-67 - REFUELING ON BATTERY
The busbars 501PP and 502PP may be supplied from three different sources:
in normal configuration when all the electrical network is supplied (either by the main generator, or the APU
generator or the external power unit) and whatever the status of the refuel door position switch :
. the busbar 501PP is supplied by the busbar 4PP and the busbar 502PP by the busbar 6PP,
in ground service configuration with the refuel door position switch open:
. the busbar 501PP and 502PP are only supplied by the busbar 6PP,
in battery only configuration with the refuel door position switch open and the REFUEL ON BAT switch (6PR)
in BAT position:
. the busbar 501PP is supplied by the battery 1 and the busbar 502PP is supplied by the battery 2,
. in any other configuration the busbars 501PP and 502PP are not supplied.
Figure 24-67-00-12150-00-A / SHEET 1/1 - Refuelling on Battery - Component Location
Figure 24-67-00-12200-00-A / SHEET 1/2 - Refuel/Defuel Control Panel (Refuelling on Battery) - Component
Location
Figure 24-67-00-12200-00-A / SHEET 2/2 - Refuel/Defuel Control Panel (Refuelling on Battery) - Component
Location
Figure 24-67-00-13350-00-B / SHEET 1/1 - Refuelling on Battery - Schematic
End of document
Page 8 of 8