ALARM/
ALERT
CODE
T051
ALARM
OR
ALERT
Alert
T052
Alert
Circuit A, Compressor 2
Failure
T053
Alert
T054
RESET
METHOD
PROBABLE
CAUSE
Manual
Manual
Circuit A, Compressor 3
Failure
Manual
Alert
Circuit A, Compressor 4
Failure
Manual
T055
Alert
Circuit B, Compressor 1
Failure
Manual
T056
Alert
Circuit B, Compressor 2
Failure
Manual
T057
Alert
Circuit B, Compressor 3
Failure
Manual
A060
Alarm
Automatic
A061
Alarm
Automatic
T064
Alert
Automatic
T065
Alert
Automatic
T066
Alert
Alert
T068
Alert
T069
Alert
T073
Alert
Compressor A1 Suction
Gas Thermistor Failure
(T7)
Compressor B1 Suction
Gas Thermistor Failure
(T8)
Outside Air Thermistor
Failure (T9)
T074
Alert
Space Temperature
Thermistor Failure (T10)
T077
Alert
Circuit A Saturated
Suction Temperature
exceeds Cooler Leaving
Fluid Temperature
Automatic
T067
T078
Alert
Circuit B Saturated
Suction Temperature
exceeds Cooler Leaving
Fluid Temperature
Saturated suction is
greater than leaving fluid
temperature for more than
5 minutes
Automatic
T079
Alert
Lead/Lag Thermistor
Failure
Automatic
DESCRIPTION
Circuit A, Compressor 1
Failure
54
ACTION TAKEN
BY CONTROL
Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
ALARM
WHY WAS THIS
ACTION TAKEN
OR
DESCRIPTION
ALARM
BY CONTROL
ALERT
GENERATED?
Alert Circuit A High Suction If EXV is greater than
Circuit A shutdown after
Superheat
98%, suction superheat is pumpdown complete.
greater than 75 F (41.7 C)
and saturated suction
temperature is less than
MOP for 5 minutes*
T113
Alert
T114
Alert
T115
Alert
T116
Alert
T117
Alert
T118
Alert
T119
Alert
CCN
CPCS
CXB
EMM
EWT
EXV
FSM
LCW
LWT
MBB
MOP
WSM
RESET
METHOD
PROBABLE
CAUSE
Manual
Faulty expansion
valve or EXV board,
low refrigerant
charge, plugged filter drier, faulty suction gas thermistor
(T7) or cooler thermistor (T5).
Faulty expansion
valve or EXV board,
low refrigerant
charge, plugged filter drier, faulty suction gas thermistor
(T8) or cooler thermistor (T6).
Faulty expansion
valve or EXV board,
faulty suction gas
thermistor (T7) or
cooler thermistor
(T5).
Manual
Automatic restart
after first daily
occurrence.
Manual restart
thereafter.
Automatic restart
after first daily
occurrence.
Manual restart
thereafter.
Faulty expansion
valve or EXV board,
faulty suction gas
thermistor (T8) or
cooler thermistor
(T6).
Manual
Manual
LEGEND
Carrier Comfort Network
Compressor Protection Control System
Compressor Expansion Board
Energy Management Module
Entering Fluid Temperature
Electronic Expansion Valve
Flotronic System Manager
Leaving Chilled Water
Leaving Fluid Temperature
Main Base Board
Maximum Operating Pressure
Water System Manager
55
ALARM
OR
ALERT
Alarm
A151
Alarm
Illegal Configuration
A152
Alarm
T153
DESCRIPTION
Emergency Stop
ACTION TAKEN
BY CONTROL
RESET
METHOD
Chiller shutdown
without going
through pumpdown.
Automatic once
CCN command for
EMSTOP returns
to normal
Manual once configuration errors
are corrected
Automatic once
alarms/alerts are
cleared that prevent the chiller
from starting.
Automatic when
correct clock control restarts.
Chiller is not
allowed to start.
Alert
A154
Alarm
T155
Alert
Serial EEPROM
Hardware Failure
Serial EEPROM
Storage Failure
A156
Alarm
Configuration/storage
failure with MBB
Chiller is not
allowed to run.
Manual
A157
Alarm
Alert
A172
Alarm
T173
Alert
T174
Alert
4 to 20 mA Cooling
Set Point Input Failure
T176
Alert
T177
Alert
4 to 20 mA Demand
Limit Input Failure
Chiller is not
allowed to run.
Compressors A3,
A4 and B3 and
unloaders A2/B2
unable to operate.
Chiller shutdown
without going
through pumpdown.
4 to 20 mA temperature reset disabled.
Demand Limit set to
100%. 4 to 20 mA
set point disabled.
Set point function
disabled. Chiller
controls to CSP.1.
Manual
T170
Critical Serial
EEPROM Storage
Failure
A/D Hardware
Failure
Loss of Communication with CXB
A200
Alarm
A201
Alarm
A202
Alarm
56
Chiller is unable
to run.
Manual
Manual
Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
PROBABLE
CAUSE
CCN Network
command.
Configuration
error. See Note on
page 57.
Alarm notifies user
that chiller is100%
down.
Time/Date/Month/
Day/Year not properly set.
Main Base Board
failure.
Potential failure of
MBB. Download
current operating
software. Replace
MBB if error
occurs again.
Main Base Board
failure.
Main Base Board
failure.
Wiring error, faulty
wiring or failed
CXB module.
Wiring error, faulty
wiring or failed
EXV module.
Wiring error, faulty
wiring or failed
Energy Management Module
(EMM).
Faulty signal generator, wiring
error, or faulty
EMM.
Faulty signal generator, wiring
error, or faulty
EMM.
Faulty signal generator, wiring
error, or faulty
EMM.
Manual
Failure of cooler
pump, flow switch,
or interlock.
Manual
Failure of cooler
pump, flow switch,
or interlock.
Manual
Failure of cooler
pump relay or
interlock, welded
contacts.
ALARM
OR
ALERT
Alert
ACTION TAKEN
BY CONTROL
RES
METHOD
PROBABLE
CAUSE
Automatic
Automatic
Alert
Master and slave chiller Dual chiller routine dishave the same CCN
abled. Master/slave run
address (CCN.A)
as stand-alone chillers.
Automatic
T206
Alert
Automatic
A207
Alarm
Cooler Freeze
Protection
T204
Alert
T205
A208
Alarm
T950
Alert
No communications
have been received by
MBB within 5 minutes
of last transmission
T951
Alert
No communications
have been received by
MBB within 5 minutes
of last transmission
CCN
CPCS
CXB
EMM
EXV
FSM
LCW
LWT
MBB
MOP
WSM
DESCRIPTION
Loss of Communication with Slave Chiller
LEGEND
Carrier Comfort Network
Compressor Protection Control System
Compressor Expansion Board
Energy Management Module
Electronic Expansion Valve
Flotronic System Manager
Leaving Chilled Water
Leaving Fluid Temperature
Main Base Board
Maximum Operating Pressure
Water System Manager
Automatic for
first occurrence
of day. Manual
reset thereafter.
Manual
Automatic
Automatic
9
10
11
12
13
14
15
16
57
Unit type = 0.
4 Compressors in a circuit with 2 unloaders.
4 Compressors in a circuit with 1 unloader and hot gas bypass.
2 Unloaders and hot gas bypass in a circuit.
More than one compressor difference between circuits
(e.g., 4 compressors in circ. A, 2 in circ. B).
Water cooled units with thermistors and configured for head
pressure control.
Unit type 2, 3, 4 with thermistors and EXV.
Low temperature brine selected for air cooled chillers or split
systems with air cooled head pressure control.
Water cooled unit configured for air cooled head pressure.
Air cooled head pressure control with common fan staging and
different head pressure control methods for each circuit (EXV
controlled vs. setpoint controlled).
Lead/lag enabled, Master selected and Cooling Setpoint select
is LWT POT.
Water cooled or split units (units types 2, 3, 4) with more than
one compressor on a circuit.
Condenser pump interlock enabled on air cooled unit.
Low Pressure Setpoints Out of Range. This is only checked
when transducers are installed. The range for the setpoint is a
function of the fluid type. For water or medium brine, the range
is 10 - 60 F, for low brine it is 3 - 60 F.
Conflicting occupancy schedules.
Cooler Fluid type is water and ice mode is enabled.