Académique Documents
Professionnel Documents
Culture Documents
CONTENTS
CONTENTS
ITEM 98674
DIGITAL MULTIMETER
OPERATION MANUAL
1.
SAFETY INFORMATION
1.1
PRELIMINARY
1.2
1.3
SYMBOLS
1.4
MAINTENANCE
2.
DESCRIPTION
2.1
NAMES OF PARTS
2.2
2.3
10
3.
SPECIFICATIONS
12
3.1
GENERAL SPECIFICATIONS
12
3.2
TECHNICAL SPECIFICATIONS
13
4.
OPERATION INSTRUCTION
23
4.1
MISCONNECTION ALARM
23
4.2
HOLDING READINGS
24
4.3
SWITCHING FUNCTIONS
24
4.4
SWITCHING RANGES
24
4.5
25
4.6
25
4.7
BACK LIGHT
26
4.8
27
4.9
28
DIGITAL MULTIMETER
DIGITAL MULTIMETER
CONTENTS
4.10
MEASURING DC VOLTAGE
29
4.11
MEASURING AC VOLTAGE
30
4.12
MEASURING FREQUENCY
31
BE
4.13
MEASURING DUTY
32
4.14
MEASURING DC CURRENT
32
4.15
MEASURING AC CURRENT
33
4.16
MEASURING RESISTANCE
35
4.17
MEASURING CAPACITANCE
36
4.18
TESTING DIODE
36
4.19
TESTING CONTINUITY
37
4.20
38
4.21
MEASURING TEMPERATURE
39
requirements
MEASURING TEMPERATURE
WARNING
EXTREMELY CAREFUL WHEN
USING
THIS
for
GB4793.1-1995
(IEC-1010-1:1990)
(WITH THERMO-RESISTOR)
4.22
1. SAFETY INFORMATION
40
(WITH THERMOCOUPLE)
4.23
41
4.24
MEASURING LUMINANCE
41
5.
MAINTENANCE
45
5.1
45
5.2
REPLACING FUSE
45
5.3
47
6.
ACCESSORIES
48
With proper use and care, this digital multimeter will give you
years of satisfactory service.
1.1 PRELIMINARY
1.1.1 When using the meter, the user must observe all
normal safety rules concerning:
-1-
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SAFETY INFORMATION NT
Check
humidity.
1.3 SYMBOLS
- important safety information; refer to the operation
manual.
- dangerous voltage may be present.
-3-
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SAFETY INFORMATION NTS
1.4 MAINTENANCE
1.4.1 Do not attempt to remove the rear case to adjust or
repair the meter.
sign
-5-
DIGITAL MULTIMETER
DIGITAL MULTIMETER
DESCRIPTION NTS
2. DESCRIPTION
as temperature of objects.
- The digital multimeter can perform measurements of
Overload
6) Panel
7) Rotary selector
incidence of light.
11) V Hz
input jack
-7-
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SAFETY INFORMATION NTS
/ Button (/)
and
Rotary Selector
10A
1000V
CAT III
uA/mA
COM
V Hz
Input Jack
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SAFETY INFORMATION NTS
Humidity Sensor
Alternating Current
DC
Light Sensor
Diode
Microphone
Continuity buzzer
Direct Current
REL
Relative measurement
AUTO
Auto range
%RH
Battery low
Celsius units (Temperature)
Fahrenheir units (Temperature)
Relative Humidity units
Farad (Capacitance)
Ohms (Resistance)
Volts (Voltage)
Amperes (Current)
Hz
Hertz (Frequency)
Duty Cycle
dB
Decibel
Lux
Illuminance units
1) Temperature indicator
X10
Decuple
2) Humidity indicator
n m k M
3) Main indicator
- 10 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
SPECIFICATION NTS
to 4032F to 104F
to 5010F to 122F
3. SPECIFICATIONS
3.2.1 DC Voltage
Range
Resolution
400mV
0.1mV
4V
1mV
40V
10mV
400V
100mV
1000V
1V
Accuracy
- Overload protection:
NOTE:
on LCD
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
3.2.2 AC Voltage
SPECIFICATION NTS
3.2.3 DC Current
Range
Resolution
400mV
0.1mV
Accuracy
Range
Resolution
400A
0.1A
4V
1mV
4000A
1A
40V
10mV
40mA
10A
400V
100mV
400mA
100A
750V
1V
4A
1mA
10A
10mA
Accuracy
- Overload protection:
NOTE:
At small voltage range, unsteady readings will appear before
the test leads contact the circuit. This is normal because
the meter is highly sensitive. When the test leads contact
the circuit, the true reading will be shown.
- voltage drop
- 14 -
- 15 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
3.2.4 AC Current
SPECIFICATION NTS
3.2.5 Resistance
Range
Resolution
400A
0.1A
4000 A
1A
40mA
10 A
400mA
100A
4A
1mA
10A
10mA
Accuracy
- Overload protection:
Range
Resolution
400
0.1
4k
40k
10
400k(
100
4M(
1k
40M(
10k
Resolution
40nF
10pF
400nF
0.1nF
4F
1nF
40F
10nF
100F
100nF
- voltage drop
Accuracy
Accuracy
- 17 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
3.2.7 Frequency
Range
SPECIFICATION NTS
- Max. input current:
Resolution
9.999Hz
0.001Hz
99.99Hz
0.01Hz
999.9Hz
0.1Hz
9.999kHz
1Hz
99.99kHz
10Hz
199.9kHz
100Hz
Accuracy
>200kHz
- by Hz range:
Measurement range: 0 ~ 200kHz
Input voltage range: 0.5V 10V rms AC (higher input
voltage at higher frequency)
Overload protection: 250V DC or rms AC
- by V range:
NOTE:
When measuring frequency, the range by Hz range is larger
than that by the Hz of voltage range or current range, but the
value measured beyond the range is for reference only.
3.2.8 Duty
Range
Resolution
Accuracy
0.1 - 99.9%
0.1%
3.0%
- By Hz range:
Frequency response: 0 ~ 200kHz
- 19 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
SPECIFICATION NTS
3.2.10 Temperature
temperature display
Range
Resolution
0.1
0.1
display
Range
Resolution
NOTE:
The range by DUTY of the Hz range is larger than that of the
Resolution
Accuracy
20 - 95%
0.1%
5.0%RH
to 40
- Operating temperature: 0
4
2
- Overload protection:
Accuracy
to 40
32 to 104
0
- By A, mA or A range:
Accuracy
-20 to 0
5.0% of reading or 3
0 to 400
1.0% of reading or 2
400 to 1000
2.0% of reading
-4 to 32
5.0% of reading or 6
32 to 752
1.0% of reading or 4
752 to 1832
2.0% of reading
Resolution
Accuracy
40-100dB
0.1 dB
- 20 -
- 21 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
SPECIFICATION NTS
4. OPERATING INSTRUCTION
Range
Resolution
Accuracy
Lux (4000)
1 Lux
10Lux
10Lux
(40000)
4.1.1 At V Hz Duty
- Repeatability: 2%.
ranges:
OPERATING INSTRUCTION
Resolution
1mV
Function
displaying
approximate
there.
Range
1) The red lights at the 10A and COM jacks will be off
after the test leads are plugged in.
2) The buzzer will sound upon misconnection of the test
leads in the IN or mA jacks to warn the user.
- 22 -
- 23 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
to the lowest level when the highest level is reached.
leads there.
be held.
signal.
mode.
Press
Press
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
3 The meter will enter the manual range mode after the
REL button is pressed.
The
seconds.
NOTE:
1) LED, which requires a larger working current, is the
main source of back light.
value.
frequent use of the back light will shorten the life of the
batteries.
necessary.
The REL
When the
measurement
cannot
be
assured
when
the
being used.
4.7 BACK LIGHT
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
Turn
OPERATING INSTRUCTION
4.10 MEASURING DC VOLTAGE
off function.
WARNING
Beware of electrocution.
Pay special attention to avoid electric shock when
measuring high voltage.
Do not input any voltage over 1000V DC, which may
destroy the internal circuit, although a higher voltage
can be shown.
V range position.
from damage.
4.9.3 Turn the rotary selector to the required function and
range to be measured.
4.10.1 Plug the black test lead into the COM jack and the
measured is unknown.
4.9.4 Connect the common test lead first and then the
charged test lead when making connection.
for measurement.
4.10.5 Take the reading on the main indicator of the LCD.
Take
NOTE:
1) At small voltage range, unsteady readings will appear
before the test leads contact the circuit.
This is
- 29 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
selected.
OPERATING INSTRUCTION
NOTE:
1) At small voltage range, unsteady readings may appear
before the test leads contact the circuit.
This is
the test leads contact the circuit, the true reading will
be shown.
2) At the manual range mode, when only OL or -OL is
shown on the LCD, it means the measurement has
exceeded the range.
selected.
WARNING
Beware of Electrocution.
Pay special attention to avoid electric shock when
measuring high voltage.
4.12.1 Plug the black test lead into the COM jack and the
can be shown.
4.11.1 Plug the black test lead into the COM jack and the red
test lead into the V jack.
4.11.2 Set the rotary selector to the
V range position.
- 31 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
4.13.1 Plug the black test lead into the COM jack and the
3)
WARNING
Beware of Electrocution.
Beware of Electrocution.
4.15.1 Plug the black test lead into the COM jack. When the
current to be measured is under 400mA, plug the red
test lead into the mA jack; when the current to be
measured is over 400mA but under 10A, plug the red
- 33 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
4.16 MEASURING RESISTANCE
A range position.
WARNING
Beware of Electrocution.
When measuring in-circuit resistance, make sure
that the power of the circuit under test has been
discharged.
NOTE:
1) At the manual range mode, when only OL or -OL is
4.16.1 Plug the black test lead into the COM jack and the
red test lead into the jack.
selected.
2) Under the manual range mode, when the scale of the
value to be measured is unknown beforehand, set the
range to the highest.
3)
range position.
This is normal
- 35 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
4.18.3 Press the "SELECT" button to switch to
test.
4.18.4 Connect the red test lead to the anode and the black
WARNING
Beware of Electrocution.
To avoid electric shock, make sure that the
capacitors
NOTE:
have
been
fully
discharged
before
jack.
range position.
to
the
two
ends
of
the
capacitor
for
measurement.
4.17.4 Take the reading on the main indicator of the LCD.
Beware of Electrocution.
NOTE:
range position.
for
continuity test.
4.18 TESTING DIODE
4.19.4 Connect the test leads to the two ends of the circuit
4.18.1 Plug the black test lead into the COM jack and the
red test lead into the
jack.
for measurement.
4.19.5 If the resistance of the circuit being tested is less than
range position.
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
4.21 MEASURING TEMPERATURE
(WITH THERMO-RESISTOR)
NOTE:
If the test leads are open or the resistance of the circuit is
4.21.2 Turn the rotary selector away from the OFF position.
4.20 MEASURING RELATIVE HUMIDITY
4.20.2 Turn the rotary selector away from the OFF position.
4.20.3 The current ambient humidity will be shown on the
humidity display of the LCD.
NOTE:
and
measurement.
NOTE:
1
environment.
Furthermore,
it
takes
longer
Hence it is not
temperature.
is
applicable
for
measuring
ambient
- 39 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
OPERATING INSTRUCTION
4.23 MEASURING SOUND LEVEL (dB)
(WITH THERMOCOUPLE)
WARNING
WARNING
Beware of electrocution.
To avoid electrical shock, do not connect the
4.23.2 Point the sensor located in the front part of the meter
at the sound source.
4.22.3 Plug the red end of the K type thermocouple into the
TEMP jack and black end into the COM jack.
Touch
or
measurement.
WARNING
To avoid damage to the meter, do not connect the
input plug to any electric signal.
4.24.1 Turn the rotary selector to the Lux or 10Lux range
position.
4.24.2 Point the sensor located in the front part of the meter
at the light source.
4.24.3 The luminance (in Lux) will be shown on the LCD.
- 40 -
- 41 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
NOTE:
1
When
100
80
OPERATING INSTRUCTION
clerical work
700 ~ 1,500
typing
1000 ~ 2,000
Factory
packing, passage
150 ~ 300
assembly line
300 ~ 750
inspection work
750 ~ 1,500
1,500 ~ 3,000
Hotel
60
100 ~ 200
40
200 ~1,000
20
Shop
150 ~ 200
750 ~ 1,500
shop window
1,500 ~ 3,000
Hospital
3 Recommended luminance:
Location
staircase, corridor
ward, warehouse
Lux
Home
100 ~ 200
300 ~ 750
750 ~ 1,500
70~150
School
staircase, corridor
70~150
200 ~ 750
classroom
200 ~ 750
writing, working
500~1000
laboratory, library
500 ~ 1,500
750~2000
100 ~ 300
Office
conference room, reception room
- 42 -
200 ~ 750
- 43 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
OPERATING INSTRUCTION
Appendix:
MAINTENANCE
5. MAINTENANCE
WARNING
should be replaced.
5.1.2 Loosen the fixing screw of the battery cover and
remove it.
5.1.3 Replace the exhausted batteries with new ones.
5.1.4 Put the battery cover back and fix it again to its origin
form.
NOTE:
Do not reverse the poles of the batteries.
- 45 -
DIGITAL MULTIMETER
DIGITAL MULTIMETER
MAINTENANCE
5.2.4 Put the battery cover back and fix it again to its
MAINTENANCE
5.3 REPLACING TEST LEADS
original form.
WARNING
WARNING
meter.
+
+
A
AA
A
AA
+
-
- 46 -
- 47 -
DIGITAL MULTIMETER
ACCESSORIES
6. ACCESSORIES
1) Test leads: electric rating: 1000V 10A
1 pair (set)
1 set
3) Operation Manual
1 copy
- 48 -
HYS005958