Vous êtes sur la page 1sur 34

Optimized Integrated Solution

Engineering Solution for Cement Industry

Process
Optimization & Plant
Safety

By : Teoh Wen Han


Venue : Forest Hill Resort,
Saraburi, Thailand
Date : 12 September 2006
9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Presentation Contents
1. Gas & Dust Analysis Application in Cement Industry Processes
2. Gas Analysis at Pre-heater / Pre-calcinator
3. Gas Analysis at Kiln Inlet
4. Gas Analysis & Level Measurement at Coal Mill / Silo
5. Gas & Dust Analysis before Electrostatic Precipitator
6. Gas & Dust Analysis before CEMS for Cement Plant
7. Questions & Answers
9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas/Dust Analysis Application in Cement Industry

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Reasons of Gas Analysis in Cement Process


Saving of energy
By optimized burning process control
Measuring Points : Pre-calcinator, Kiln Inlet
Constant high production quality
Constant kiln operation control
Measuring Points : Pre-heater, Pre-calcinator, Kiln Inlet
Plant safety
Protection of the electrostatic precipitator
Protection of the coal grinding plant
Measuring Points : Before E.P., Coal grinding mill

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Reasons of Gas Analysis in Cement Process


Reduction of the operating costs
High availability of the plant equipment
Early recognition of critical situations

Reduced emission / Environmental protection


Emission control by monitoring the burning process
Emission monitoring and data acquisition

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Preheater / Precalcinator

Measurement Task
CO, O2 Combustion

optimization of secondary
furnace
CO2 Degree of calcination
CaCO3 (lime) CaO + CO2

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Preheater / Precalcinator

Process Condition
850 C (1562 F)
200 g/m dust
Components: CO, O2 and CO2

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Preheater / Precalcinator


Sampling Probe System

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Preheater / Precalcinator

Sampling Probe

9th TCMA Technical Workshop

Sampling Conditioning System


with Analyzer Located @
Pre-heater Tower
www.bnf.com

Optimized Integrated Solution

Gas Analysis at Kiln Inlet


Measurement Task
CO, O2 Combustion optimization
SO2, NO Quality of cement
CO2 Degree of calcination
CaCO3 => CaO + CO2

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Kiln Inlet

Process Condition
1400 C (2552 F)
200 - 2000 g/m Dust
Components: CO, O2, NO, CO2, SO2

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Kiln Inlet

Gas Sampling Probe KIP 1000R

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Kiln Inlet


KIP 1000R System Solution consist of
1.

Gas Sampling Probe System

2.

Cooling System & Heat Exchanger System

3.

Gas Conditioning and Analyzer System

4.

Integrated Hybrid Control System

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Kiln Inlet


ANIMATION OF KIP 1000R

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Coal Mill / Silo


Measurement Task 1 : Coal bunker is filled with ambient air
CO Measurement Detection of smouldering

Measurement Task 2 :
Coal bunker is filled with
Inert gas (Example : N2)
O2 Measurement N2 leak
detection

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Coal Mill / Silo


Coal Mill Inlet

O2
O2

Purging
System
Gas
Cooler

Mill Filter Outlet


Purging
System

CO

Gas
Cooler

Sample
Switching
System

Mill Filter Outlet


Purging
System

Configuration of Sample Switching System

Coal Silo
Purging
System

Switching
3-way
solenoid

Coal Silo
Purging
System

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Coal Mill / Silo

Photos showing an Analyzer Panel with Sample Switching System


9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas Analysis at Coal Mill / Silo

Sampling on top of the coal silo

Coal mill with analyzer cabinets on


Level 5 (Silo) and Level 6 (Filter)

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Level Measurement at Coal Mill / Silo

Measurement Methods /
Installation
1. Vertical from top, rigid shaft.
2. Vertical from top flexible shaft or
cable boom.

3. Horizontal,lateral of bin
4. Horizontal, lateral of bin with
inclined flange

5. Inclined
4

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter

Process Condition
600 C (1112 F)
12 g/m dust (Before EP)
50 mg/m dust (After EP)
Components: CO, O2

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


OVERVIEW
Dust
Monitors

Dust
Monitors

Stack gas
in front of E-Filter

Stack gas
after E-Filter

Dust < 12 g/m

Dust < 50 mg/m


Gas
Analyzer

9th TCMA Technical Workshop

Add. quick CO
measurement
to avoid explosions

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


Methods in Determination of Dust Concentration
Transmission
Opacity
Extinction

Ringelmann

Dust
mg/m3

Bacharach
Dust
Measurement
Flicker light
Scintillation

Triboflow

Gravimetric
comparison

Beta Ray
Scatter light
Transmission
9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


Measuring principle

Type

Procedure

Gravimetric measurement

extractive

discontinuous

Beta Ray

extractive

discontinuous

Scatter light wet gas

extractive

discontinuous

Scatter light dry gas

in - situ

continuous

Triboflow

in - situ

continuous

Flickerlight

in - situ

continuous

Transmission

in - situ

continuous

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Different effects occurring when illuminating a particle


reflection

Light

diffraction
absorption

refraction

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


Dust Analysis
1.

In-situ Cross Stack System

Typically used before EP ( High Dust )

Dual path measurement

Wide measuring range ( 0 12 g/m3 )

2.

In-situ Probe Type

Typically installed after EP ( Low Dust )

Laser scattered light measurement

Sensitive for low dust measurement


( 0 200 mg/m3)

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


Gas Analysis
1.

Extractive System

The sampling line must be as short as


possible

Design is similar to Coal Mill Application

2. In-Situ System

Permeation Probe for fast and accurate


measurement

2 sec response time

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust Analysis before Electrostatic Filter


Purpose Of Measuring

To monitor the efficiency of Electrostatic Precipitator


(or broken bag filter)

For plant safety ( high CO concentration can cause


explsion on the EP )

For emission monitoring

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant


Process Condition
200 C (Main Stack)
400 mg/m (Dust)
~ 30 Vol% (Moisture Content)
Components: CO, CO2 , O2 , SO2 , NOX ,THC, HCl
System MUST Comply to Local Environmental
Regulation
9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant


Measurement Techniques for Gas
Extractive System
-

Hot Wet Measurement (HW)

Cold Dry Measurement (CD)

Permeation Drying Measurement (PD)

Gas Dilution Measurement Technology

Depending on gas component, utilities availability, etc

In-Situ System

- Cross Stack Type


- Probe Type

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant


Features of Extractive Gas CEMS System

Require Sampling System, more component

CD and PD need Sampling Conditioning System

Possible Time Sharing for multi stacks

Easy Auto or Manual System Calibration by Reference


Gas

Dual Measurement Range is possible

Analyzer should be placed as close as possible to the


sampling point

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant


Features of In-situ Gas CEMS System
No Sampling System
Fast Response (not dependent of SCS tube
length)
No Time Sharing for Multi Stacks
Multi gas in one analyzer is possible

Wet Measurement need H2O measurement for


dry value reporting
Difficult to conduct system calibration by gas
cylinder
Dual Measurement Range may not be possible
Gas Measurement can be influenced by stack
moisture
9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant


Measurement Techniques for Dust
In-situ Measurement
1. Cross Stack Version
For use in medium to high dust measurements
Capable of catering large ducts, up to 15 m dia.
Able to use in high temperature (up to 600 OC)
exhaust points such as Cooler Stack

2. Probe Version
For use in low to medium dust measurements
One-side installation
Typically used to measure after EP or bag filter

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Gas & Dust CEMS for Cement Plant

3. Heated Bypass Version


For use in measuring of dust in wet gas
Flue gas maximum temperature 200 OC
Measuring cell & thermo-cyclone in one
compact design

PTFE probe to withstand corrosion

9th TCMA Technical Workshop

www.bnf.com

Optimized Integrated Solution

Thank You For Your Attention

Questions?
9th TCMA Technical Workshop

www.bnf.com

Vous aimerez peut-être aussi