Vous êtes sur la page 1sur 32

CONFIDENTIAL

FL Series Connector Design Guide

Revision 2.0
December, 2009

HIROSE ELECTRIC CO.,LTD.


2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

ITS-Z0173

ITS-Z0173

CONFIDENTIAL

December, 2009

Contents
FL Series Variations

--- page 3-4

U.FL

U.FL Series Overview


U.FL Receptacle
U.FL Plug
U.FL In-line Jack
U.FL Cable Guide
Cable Assembly Ordering Guide
Cable Assembly End Options

--- page 5
--- page 6
--- page 7
--- page 8
--- page 9
--- page 10 -11
--- page 12

W.FL

W.FL Series Overview


W.FL Receptacle
W.FL Plug
W.FL Cable Guide
Cable Assembly Ordering Guide
Cable Assembly End Options

--- page 14
--- page 15
--- page 16
--- page 17
--- page 18-19
--- page 20

N.FL

N.FL Series Overview


N.FL Receptacle
N.FL Plug
N.FL Cable Guide
Cable Assembly Ordering Guide
Cable Assembly End Options

--- page 21
--- page 22
--- page 23
--- page 24
--- page 25
--- page 26

Flexible Choice of Components


Hand Tool for Insertion and Extraction
Conversion Adaptors
Production Test Probe
Connector Selection Guide

--- page 27-28


--- pages 29
--- page 30
--- page 31
--- page 32

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 2

U.FL

W.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

FL Series Variations
* Mating height differs by cable size

U.FL Series
2.3mm [2.4 MAX ] -2.4mm [2.5 MAX]*

2.5

U.FL-LP-xxx

Mated Height (mm)

Lower Profile

1.9mm [2.0 MAX]

2.0

W.FL Series

U.FL-LP(V)-xxx

1.65mm [1.85MAX]

W.FL-LP(G)-xxx

Lower Profile

Lower loss

1.5

1.4mm [1.55 MAX]

W.FL-LP-xxx

N.FL Series
1.4mm [1.5 MAX]

N.FL-LP-xxx

Lower Profile

1.18mm [1.3 MAX]

W.FL2-LP-xxx
1.0

3.4

Occupied Mounting Surface (mm2)

Specifications herein are subject to change without notice.


Contact Hirose for latest specifications, drawings, or availabilities.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Issued:

7.7
Page 3

FL Series Variations

W.FL2-LP-040

W.FL-LP-040

W.FL2-R-SMT-1

W.FL-LP(G)-062

W.FL-R-SMT-1

Pattern
Compatibility*

3.4
mm2

2.0

0.7

0.85

Receptacle

2.0

Compatible

U.FL-LP-040
U.FL-LP-062
U.FL-LP-066
U.FL-LP-088

U.FL-LP(V)-040

N.FL-R-SMT-1

U.FL-R-SMT-1

Occupied
Mounting
Surface

N.FL-LP-040

U.FL Series

7.7
mm2

3.1

Plug

N.FL
Series

W.FL Series

3.1

Series

3.1

N.FL

December, 2009

1.25

W.FL

0.8

U.FL

ITS-Z0173

CONFIDENTIAL

3.0
Not Compatible
(N.FL is mountable onto U.FL pattern layout )
* Refer to page 27-28 for the details.

All dimensions are in millimeters, unless otherwise specified.


Page 4

ITS-Z0173

CONFIDENTIAL

U.FL Series

December, 2009

U.FL Series Overview


Features
Characteristic Impedance: 50 ohms
Low Profile: 1.9 mm (2.0 MAX.) or 2.3 mm (2.4 MAX.)
or 2.4 mm (2.5 MAX.) Mating Height
Small Occupied Mounting Area
Light Weight
Can Be Used with Automatic Mounting
Use of Ultra-Fine Fluoropolymer Coaxial Cable
Satisfies RoHS requirements

Small Form Factor


Receptacle

Cable Assembly

Ultra-Fine
Fluoropolymer Coaxial Cable

Plug Connector

Board Mount SMT Connector

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 5

ITS-Z0173

CONFIDENTIAL

U.FL Series

December, 2009

U.FL Receptacle
Hirose P/N: U.FL-R-SMT-1

Signal and Ground Configuration

Recommended PCB Layout

TOP VIEW

TOP VIEW
Ground Contact

Ground Pads

Signal Contact

10.05

2.20.05

Ground Contact

FRONT VIEW

1.050.05

Signal Pad

7.7
mm2

3.1

Connector Footprint

10.05
1.90.05
40.05

CUT-OUT PROHIBITION AREA

All dimensions are in millimeters, unless otherwise specified.


See customer drawing for details.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 6

ITS-Z0173

CONFIDENTIAL

U.FL
Series
U.FL
Series

December, 2009

U.FL Plug

U.FL-LP-040

U.FL-LP-066

U.FL-LP(V)-040

U.FL-LP-062

U.FL-LP-040

U.FL-LP-066

U.FL-LP(V)-040

U.FL-LP-062

U.FL-LP-088

U.FL-R-SMT-1

Applicable
Coaxial
Cable
( mm)

U.FL-R-SMT-1

U.FL-R-SMT-1

U.FL-R-SMT-1

U.FL-R-SMT-1

1.13
0.81

(Single-shielded)

or
1.32

0.81

1.37

(Double-shielded)

068N*
Cable
Type

U.FL-LP-088
2.4 MAX.

2.4 MAX.

2.0 MAX.

Mated
Height

2.5 MAX.

2.5 MAX.

Part
Number

088N*PD

(Single-shielded)

04N*

or
066J* or 066N*

04N*

062N*D

(Double-shielded)

(Lower loss Type)

or
088K*T

Note :Cable supplier differs between 066J* and 066N*. However, performances are equivalent.
All dimensions are in millimeters, unless otherwise specified.
* mark indicates the symbols of cable color.
See customer drawing for details.

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 7

ITS-Z0173

CONFIDENTIAL

U.FL
Series
U.FL
Series

December, 2009

U.FL In-line Jack


Mating Combination

Mated Height

U.FL-LP-088

3.5 mm

U.FL-LJ-088
Frequency Range

DC to 6 GHz

High Frequency performance

V.S.W.R. 1.4 MAX

Characteristic impedance

50

Applicable cable

1.37 mm

Cable type

088N*PD (lower loss type) or 088K*T

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 8

ITS-Z0173

CONFIDENTIAL

U.FL Series

December, 2009

U.FL Cable Guide


Insertion Loss (Typical:1M long)
0
Test Method

088N*PD

Frequency range
Output level
Measurement method

45 MHz to 6GHz
0 dBm
S11, S21

Calibration Circuit

APC3.5(f)

Measurement Circuit
Vector
Network Analyzer
APC3.5(f)

APC3.5(f)

Insertion Loss (dB/m)

ECAL

062N*D

-4

Vector
Network Analyzer
APC3.5(f)

088K*T

-2

068N*

-6

066J* and 066N*


04N*

-8
SMA adapter

SMA adapter
U.FL Plug

Cable Length=1M

U.FL Plug

-10
0

Frequency (GHz)
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 9

U.FL Series

ITS-Z0173

CONFIDENTIAL

December, 2009

Cable Assembly Ordering Guide (U.FL-LP-xxx)

Double Ended

Part Number

L (Cable length) Unit:mm

U.FL-2LPCable Type

Minimum cable length: 35 mm

Single Ended

L (Cable length) Unit:mm

Soldering

L2 L3 L4

35

200

+/- 4

200

500

+/- 8

500

1000

+/- 12

1000

Cable Type

+/- 1.5 %
All dimensions are in millimeters, unless otherwise specified.

Cable Type
088N1PD
088N2PD
088K1T
088K2T
062N1D
062N2D
062N3D

L (Cable length)

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm

Cable Jacket Color


GRAY
BLACK
GRAY
BLACK
GRAY
BLACK
WHITE

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

L (Cable length) Unit:mm

Soldering

10 Max.

Minimum cable length: 35 mm


TOLERANCE

-A-(

Cable Type

Single Ended (Stripping Profile)

TO

L (Cable length) Unit:mm

U.FL-LP-

Minimum cable length: 35 mm

OVER

Part Number

L (Cable length) Unit:mm

General Dimension Tolerance (mm)

-A-(

Yes or No
Cable Type

Cable Jacket Color

068N1

GRAY

068N2

BLACK

066J1 or 066N1
066J2 or 066N2

GRAY
BLACK

04N1

WHITE

04N2

BLACK
Page 10

ITS-Z0173

CONFIDENTIAL

U.FL Series

December, 2009

Cable Assembly Ordering Guide (U.FL-LP(V)-xxx)


Double Ended

Part Number

L (Cable length) Unit:mm

U.FL-2LP(V)Cable Type

Minimum cable length: 35 mm

Single Ended

-A-(

L (Cable length) Unit:mm

Part Number

L (Cable length) Unit:mm

U.FL-LP(V)Cable Type

Minimum cable length: 35 mm

Single Ended (Stripping Profile)


L (Cable length) Unit:mm

Soldering

L2 L3 L4

General Dimension Tolerance (mm)

L (Cable length) Unit:mm

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm
Yes or No

Cable Type

OVER

TO

TOLERANCE

Cable Type

Cable Jacket Color

35

200

+/- 4

04N1

WHITE

200

500

+/- 8

500

1000

+/- 12

04N2

BLACK

1000

L (Cable length)

Soldering

10 Max.

Minimum cable length: 35 mm

-A-(

+/- 1.5 %
All dimensions are in millimeters, unless otherwise specified.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 11

ITS-Z0173

CONFIDENTIAL

U.FL Series

December, 2009

Cable Assembly End Options


End 2

End 1

Available
options
End 1 Connector

Cable type

FL Seires
U.FL-LP-040
U.FL-LP(V)-040

04N*
( 0.81)
HRM Series

U.FL-LP-062

062*D ( 1)

FL Series
FL Series
BNC Series
TNC Series

068N*

U.FL-LP-066

1.13 (Single-shielded)

N Series

or
066J* or 066N*
1.32 (Double-shielded)

MMCX Series

HRM Series

BNC Series
088N*PD (lower loss type)
1.37)
U.FL-LP-088

TNC Series
N Series

or

MMCX Series

088K*T
( 1.37)

N.UM Series

HRM Series

End 2 Connector
E.FL-LP-040
U.FL-LP-040
U.FL-LP(V)-040
W.FL-LP-040
W.FL2-LP-040
N.FL-LP-040
HRM-200-040PBN(40)
HRM-200-040JBN(40)
HRM-200-040PJ2BN(40)
HRM-200-040PJ4BN(40)
HRM-200-040BPJBN(40)
W.FL-LP(G)-062
H.FL-LP-A32-A
E.FL-LP-066
BNC-BPJ-FHSB(40)
TNC-BPJ-1.32(40)
N-WPJ-0733H(40)
N-WPP-FHSBH(40)
MMCX-LP-066 (40)

End 2 connectors satisfy


RoHS requirements.

Plug

Plug
Jack
Panel Jack (2-hole)
Panel Jack (4-hole)
Panel Jack (Bulkhead)
Plug
Plug

Panel Jack (Bulkhead)


Panel Jack (Bulkhead)
Waterproof Panel Jack
Waterproof Panel Plug
Right Angled Plug
MMCX-P-066(40)
Straight Plug
MMCX-BPJ-066(40)
Panel Jack (Bulkhead)
HRM-200-066PBN(40)
Panel Jack (Bulkhead)
HRM-200-066JBN(40)
Jack
HRM-200-066PJ2BN(40)
Panel Jack (2-hole)
HRM-200-066PJ4BN(40)
Panel Jack (4-hole)
HRM-200-066BPJBN(40)
Panel Jack (Bulkhead)
BNC-BPJ-FHSB(40)
Panel Jack (Bulkhead)
TNC-WPJ-FHSB(40)
Waterproof Panel Jack
TNC-J-FHSB-A(40)
Jack
TNC-WBPJ-FHSB-A(40) Waterproof panel Jack (Bulkhead)
N-WPJ-FHSBH(40)
Waterproof Panel Jack
MMCX-LP-088(40)
Right Angled Plug
MMCX-P-088(40)
Straight Plug
N.UM-PJ-FHSB-2(40)
Panel Jack
HRM-200-088PBN(40)
Plug
HRM-200-088JBN(40)
Jack
HRM-200-088PJ2BN(40)
Panel Jack (2-hole)
HRM-200-088PJ4BN(40)
Panel Jack (4-hole)
HRM-200-088BPJBN(40)
Panel Jack (Bulkhead)

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 12

ITS-Z0173

CONFIDENTIAL

W.FL Series

December, 2009

W.FL Overview

Features
Low Profile: 1.18 mm (2.0 MAX) or 1.4 mm (1.55 MAX)
or 1.65 mm (1.85 MAX.) Mating Height
Small Occupied Mounting Area
Light Weight
Can Be Used with Automatic Mounting
Use of Ultra-Fine Fluoropolymer Coaxial Cable
Satisfies RoHS requirements

Small Form Factor


Receptacle

Cable Assembly

Ultra-Fine
Fluoropolymer Coaxial Cable

Plug Connector

Board Mount SMT Connector

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 13

ITS-Z0173

CONFIDENTIAL

W.FL
W.FLSeries
Series

December, 2009

W.FL Receptacle
Hirose P/N: W.FL-R-SMT-1
W.FL2-R-SMT-1

W.FL-R-SMT-1

W.FL2-R-SMT-1

Ground Contact

TOP VIEW

2.60.05
1.40.05

Ground Contact
Ground Contact

Ground Contact

0.50.05

1.30.05

TOP VIEW

Recommended PCB Layout

Ground Contact

Ground Pad

1.50.05

Signal and Ground Configuration

Ground Pad

FRONT VIEW

Signal Pad

Ground Pad

2.0

3.4
mm2

0.650.05

1.30.05

Signal Contact

2.0

CUT-OUT PROHIBITION AREA

All dimensions are in millimeters, unless otherwise specified.


See customer drawing for details.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 14

ITS-Z0173

CONFIDENTIAL

W.FL Series

December, 2009

W.FL Plug
W.FL-LP-040

W.FL-LP(G)-062

W.FL2-LP-040

W.FL2-LP-040

W.FL-LP(G)-062

1.3 MAX.

Mated
Height

W.FL-LP-040

1.85 MAX.

1.55 MAX.

Part
Number

W.FL-R-SMT-1

W.FL-R-SMT-1

W.FL2-R-SMT-1

Applicable
Coaxial
Cable
( mm)

0.81

0.81

Cable Type

04N*

062N*D

04N*

* mark indicates the symbols of cable color.


2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

All dimensions are in millimeters, unless otherwise specified.


See customer drawing for details.
Page 15

ITS-Z0173

CONFIDENTIAL

W.FL Series

December, 2009

Available Cable Types


Insertion Loss (Typical:1M long)
0
Test Method
Frequency range
Output level
Measurement method

45 MHz to 6GHz
0 dBm
S11, S21

-2
062N*D

Vector
Network Analyzer
APC3.5(f)

ECAL

APC3.5(f)

Measurement Circuit
Vector
Network Analyzer
APC3.5(f)

APC3.5(f)

-4

-6

04N*

-8

SMA adapter

SMA adapter
W.FL Plug

Insertion Loss (dB/m)

Calibration Circuit

Cable Length=1M

W.FL Plug

-10
0

Frequency (GHz)
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

[GHz]

Page 16

W.FL
W.FLSeries
Series

ITS-Z0173

CONFIDENTIAL

December, 2009

Cable Assembly Ordering Guide (W.FL-LP-xxx)

Double Ended

Part Number

L (Cable length) Unit:mm

W.FL-2LPCable Type

Minimum cable length: 35 mm

Single Ended

-A-(

L (Cable length) Unit:mm

Part Number

L (Cable length) Unit:mm

W.FL-LPCable Type

Minimum cable length: 35 mm

Single Ended (Stripping Profile)


L (Cable length) Unit:mm

Soldering

L2 L3 L4
10 Max.

Minimum cable length: 35 mm

General Dimension Tolerance (mm)


OVER

TO

TOLERANCE

35

200

+/- 4

200

500

+/- 8

500

1000

+/- 12

1000

Cable Type

L (Cable length) Unit:mm

L (Cable length)

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm

Soldering
Cable Type
04N1
04N2

-A-(

Yes or No

Cable Jacket Color


WHITE
BLACK

+/- 1.5 %
All dimensions are in millimeters, unless otherwise specified.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 17

W.FL
W.FLSeries
Series

ITS-Z0173

CONFIDENTIAL

December, 2009

Cable Assembly Ordering Guide (W.FL-LP(G)-xxx)

Double Ended

Part Number

L (Cable length) Unit:mm

W.FL-2LPGCable Type

Minimum cable length: 35 mm

Single Ended

-A-(

L (Cable length) Unit:mm

Part Number

L (Cable length) Unit:mm

W.FL-LPGCable Type

Minimum cable length: 35 mm

Single Ended (Stripping Profile)


L (Cable length) Unit:mm

Soldering

L2 L3 L4
Minimum cable length: 35 mm

General Dimension Tolerance (mm)


OVER

TO

TOLERANCE

35

200

+/- 4

200

500

+/- 8

500

1000

+/- 12

1000

10 Max.

Cable Type

-A-(

L (Cable length) Unit:mm

L (Cable length)

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm

Soldering

Cable Type

Cable Jacket Color

062N1D

GRAY

062N2D

BLACK

062N3D

WHITE

Yes or No

+/- 1.5 %
All dimensions are in millimeters, unless otherwise specified.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 18

W.FL
W.FLSeries
Series

ITS-Z0173

CONFIDENTIAL

December, 2009

Cable Assembly Ordering Guide (W.FL2-LP-xxx)

Double Ended

Part Number

L (Cable length) Unit:mm

W.FL2-2LPCable Type

Minimum cable length: 35 mm

Single Ended

-A-(

L (Cable length) Unit:mm

Part Number

L (Cable length) Unit:mm

W.FL2-LPCable Type

Minimum cable length: 35 mm

Single Ended (Stripping Profile)


L (Cable length) Unit:mm

Soldering

L2 L3 L4
10 Max.

Minimum cable length: 35 mm

General Dimension Tolerance (mm)

Cable Type

L (Cable length) Unit:mm

L (Cable length)

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm

Soldering

OVER

TO

TOLERANCE

Cable Type

Cable Jacket Color

35

200

+/- 4

04N1

WHITE

200

500

+/- 8

04N2

BLACK

500

1000

+/- 12

1000

-A-(

Yes or No

+/- 1.5 %
All dimensions are in millimeters, unless otherwise specified.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 19

ITS-Z0173

CONFIDENTIAL

W.FL
W.FLSeries
Series

December, 2009

Cable Assembly End Options


End 2

End 1

Available
options

End 1 Connector

Cable type
FL Seires

W.FL-LP-040

04N*
( 0.81)
HRM Series

W.FL-LP(G)-062

062N*D ( 1)

FL Series

FL Series
W.FL2-LP-040

04N*
( 0.81)
HRM Series

End 2 Connector
E.FL-LP-040
U.FL-LP-040
U.FL-LP(V)-040
W.FL2-LP-040
N.FL-LP-040
HRM-200-040PBN(40)
HRM-200-040JBN(40)
HRM-200-040PJ2BN(40)
HRM-200-040PJ4BN(40)
HRM-200-040BPJBN(40)
U.FL-LP-062
E.FL-LP-040
U.FL-LP-040
U.FL-LP(V)-040
W.FL-LP-040
N.FL-LP-040
HRM-200-040PBN(40)
HRM-200-040JBN(40)
HRM-200-040PJ2BN(40)
HRM-200-040PJ4BN(40)
HRM-200-040BPJBN(40)

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

End 2 connectors satisfy


RoHS requirements.

Plug

Plug
Jack
Panel Jack (2-hole)
Panel Jack (4-hole)
Panel Jack (Bulkhead)
Plug

Plug

Plug
Jack
Panel Jack (2-hole)
Panel Jack (4- hole)
Panel Jack (Bulkhead)

Page 20

ITS-Z0173

CONFIDENTIAL

N.FL Series

December, 2009

N.FL Series Overview

Features
Characteristic Impedance: 50 ohms
Low Profile: 1.4 mm (1.5 MAX.) Mating Height
Small Occupied Mounting Area
Light Weight
Can Be Used with Automatic Mounting
Use of Ultra-Fine Fluoropolymer Coaxial Cable
Satisfies RoHS requirements

Small Form Factor


Receptacle

Cable Assembly

Ultra-Fine
Fluoropolymer Coaxial Cable

Plug Connector

Board Mount SMT Connector

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 21

ITS-Z0173

CONFIDENTIAL

N.FL Series

December, 2009

N.FL Receptacle
Hirose P/N: N.FL-R-SMT-1

Signal and Ground Configuration


Ground Contact

TOP VIEW
Ground Contact

Signal Contact

2.050.05

FRONT VIEW

Ground Pads

20.05

Ground Contact

1.850.05

TOP VIEW

Recommended PCB Layout

Connector Footprint

Signal Pad

0.80.05

7.7
mm2

3.1

1.90.05
3.80.05
CUT-OUT PROHIBITION AREA

All dimensions are in millimeters, unless otherwise specified.


See customer drawing for details.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 22

CONFIDENTIAL

U.FL
Series
N.FL
Series

ITS-Z0173

December, 2009

N.FL Plug

2.8

N.FL-LP-040

Part Number

Mated Height

1.5 MAX.

1.12

3.4

Applicable
Coaxial
Cable
( mm)

0.81

Cable Type

04N*

* mark indicates the symbols of cable color.


2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

All dimensions are in millimeters, unless otherwise specified.


See customer drawing for details.
Page 23

ITS-Z0173

CONFIDENTIAL

N.FL Series

December, 2009

N.FL Cable Guide


Insertion Loss (Typical:1M long)
0

Test Method
45 MHz to 6GHz
0 dBm
S11, S21

-2

Calibration Circuit
Vector
Network Analyzer
APC3.5(f)

ECAL

APC3.5(f)

Measurement Circuit

Insertion Loss (dB/m)

Frequency range
Output level
Measurement method

-4

04N*

-6

Vector
Network Analyzer
APC3.5(f)

APC3.5(f)

-8
SMA adapter

SMA adapter
N.FL Plug

Cable Length=1M

N.FL Plug

-10
0

Frequency (GHz)
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 24

ITS-Z0173

CONFIDENTIAL

N.FL Series

December, 2009

Cable Assembly Ordering Guide


Double Ended

Part Number

L (Cable length) Unit:mm

N.FL-2LPCable Type

Minimum cable length: 35 mm

Single Ended

-A-(

L (Cable length) Unit:mm

Part Number

L (Cable length) Unit:mm

N.FL-LPCable Type

Minimum cable length: 35 mm

Single Ended (Stripping Profile)


L (Cable length) Unit:mm

Soldering

L2 L3 L4
10 Max.

General Dimension Tolerance (mm)


OVER

TO

TOLERANCE

35

200

+/- 4

200

500

+/- 8

500

1000

1000

Cable Type

Cable Type
04N1
04N2

L (Cable length) Unit:mm

L (Cable length)

mm

L2 (Outer shield)

mm

L3 (Insulator)

mm

L4 (Center conductor)

mm

Soldering

Minimum cable length: 35 mm

-A-(

Yes or No

Cable Jacket Color


WHITE
BLACK

+/- 12
+/- 1.5 %

All dimensions are in millimeters, unless otherwise specified.


2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 25

ITS-Z0173

CONFIDENTIAL

N.FL Series

December, 2009

Cable Assembly End Options


End 1

End 2
Available
options

End 1 Connector

Cable type
FL Series

N.FL-LP-040

04N*
( 0.81)
HRM Series

End 2 Connector
E.FL-LP-040
U.FL-LP-040
W.FL-LP-040
W.FL2-LP-040
HRM-200-040PBN(40)
HRM-200-040JBN(40)
HRM-200-040PJ2BN(40)
HRM-200-040PJ4BN(40)
HRM-200-040BPJBN(40)

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

End 2 connectors satisfy


RoHS requirements.

Plug
Plug
Jack
Panel Jack (2-hole)
Panel Jack (4-hole)
Panel Jack (Bulkhead)

Page 26

W.FL
W.FLSeries
Series

ITS-Z0173

CONFIDENTIAL

December, 2009

Flexible Choice of Components


Mating height in parenthesis.

Lower Profile Type


W.FL2-LP-040 (1.18 mm)
W.FL-LP-040 (1.4 mm)

Lower Insertion Loss Type


W.FL-LP(G)-062
(1.65 mm)
W.FL2-R-SMT-1

W.FL-R-SMT-1

Common PCB layout provides


scalability of connectors.

Specifications herein are subject to change without notice.


Contact Hirose for latest specifications, drawings, or availabilities.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 27

U.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

Flexible Choice of Components


Mating height in parenthesis.

N.FL-LP-040 (1.4 mm)


U.FL-LP(V)-040 (1.9 mm)
U.FL-LP-xxx
(2.3 to 2.4mm)

N.FL-R-SMT-1
N.FL PCB layout

X
U.FL-R-SMT-1

U.FL PCB layout

PCB layout is not common,


but N.FL receptacle is mountable
onto U.FL pattern layout.
Specifications herein are subject to change without notice.
Contact Hirose for latest specifications, drawings, or availabilities.
2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 28

U.FL

W.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

Hand Tools for Insertion and Extraction

Connector

U.FL-LP-040
U.FL-LP-066
U.FL-LP-088

Insertion
Tool

Extraction
Tool

U.FL-LP-062
U.FL-LP(V)-040

N.FL-LP-040

(U.FL-LP-IN)

U.FL-LP-N-2

W.FL-LP-040

(W.FL-LP-IN)

U.FL-LP(V)-N-2

W.FL-LP(G)-062

W.FL2-LP-040

W.FL-LP-IN

W.FL-LP-IN
or
W.FL2-LP-IN.OUT

W.FL-LP-N

W.FL2-LP-IN.OUT

Required

Inserting operation is acceptable without tool.


Tool supports operation in small space for your convenience.

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 29

U.FL

W.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

Conversion Adaptors
HRMP- .FLJ

HRMJ- .FLP

SMA Plug to Jack Conversion Adapter


for Plug Testing

SMA Jack to Plug Conversion Adapter


for Receptacle Testing

To Measurement Equipment

To Measurement Equipment

SMA Jack Cable

SMA Plug Cable

HRMP- .FLJ

HRMJ- .FLP

Test Sample (Plug)

Plug Type
U.FL
U.FL(V)
W.FL
W.FL(G)
W.FL2
N.FL

Test Sample (Receptacle)

Adapter for Plug Testing

Receptacle Type

Adapter for Receptacle Testing

HRMP-U.FLJ (40)

U.FL

HRMJ-U.FLP(40)

HRMP-W.FLJ (40)

W.FL

HRMP-W.FL2J
HRMP-U.FLJ (40)

W.FL2
N.FL

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

HRMJ-W.FLP(40)
HRMJ-U.FLP(40)

Page 30

U.FL

W.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

Production Test Probe


Test Probe

Floating Probe

Alignment for X and Y directions

Replaceable probe head


Floats for X, Y, and Z directions

HRMJ- .FL P-ST

SMA Jack

SMA Jack

Floating Unit

HRM-PA-PJ(F)-1(40)
Mating Times: 100,000 cycles*
(* Coil spring portion)
Replaceable Probe Head

HRMJ- .FL P-ST


Mating Times: 10,000 cycles

Test Sample( Receptacle)


The probe is used by compressing the mated portion of
.FL side onto the

Test Samples (Receptacles on Radio Module)

.FL-R-SMT mated portion.

FL SERIES

PROBE

U.FL
U.FL(V)

HRMJ-U.FLP-ST2 (40)

W.FL
W.FL(G)

HRMJ-W.FLP-ST3

W.FL2

HRMJ-W.FL2P-ST3

N.FL

HRMJ-N.FLP-ST3

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 31

U.FL

W.FL

ITS-Z0173

CONFIDENTIAL

N.FL

December, 2009

Connector Selection Guide


YOUR PRIORITY

Plug
Part Number
U.FL-LP-062
U.FL-LP-088

Small
mounting
surface

Low
mating height
(mm)

Cable
varieties

High
mating
force

Low
insertion
loss

Easy
mating
operation

Optimum

Optimum

Optimum

Optimum

2.3 (2.4 MAX)

U.FL-LP-040
U.FL-LP-066

2.4 (2.5 MAX)

U.FL-LP(V)-040

1.9 (2.0 MAX)

Optimum

Optimum

N.FL-LP-040

Good
1.4 (1.5 MAX)

Optimum

Optimum

1.65 (1.85 MAX.)

Good

Optimum

Good

W.FL-LP(G)-062

7.7 mm2

W.FL-LP-040

Good
1.4 (1.55 MAX.)

W.FL2-LP-040

Optimum
1.18 (1.3MAX.)

3.4 mm2

2009, HIROSE ELECTRIC CO., LTD. All rights reserved.

Page 32

Vous aimerez peut-être aussi