Enterasys Matrix
DFE-Platinum Series
P/N 9033929-02
Notice
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthis
documentanditswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networksto
determinewhetheranysuchchangeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubjecttochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISING
OUTOFORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVEN
IFENTERASYS NETWORKSHASBEENADVISEDOF,KNEWOF,ORSHOULDHAVEKNOWNOF,THE
POSSIBILITYOFSUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
2007Enterasys Networks, Inc.Allrightsreserved.
PartNumber: 903392902 July2007
ENTERASYS NETWORKS, ENTERASYS MATRIX, LANVIEW, MATRIX, ENTERASYS NETSIGHT, WEBVIEW, and
any logos associated therewith, are trademarks or registered trademarks of Enterasys Networks, Inc., in the United States and
other countries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespective
companies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals
PRODUCT SAFETY
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,IEC60950.
PRODUKTSICHERHEIT
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,
IEC 60950.
ii
HAZARDOUS SUBSTANCES
ThisproductcomplieswiththerequirementsofEuropeanDirective,2002/95/EC,RestrictionofHazardousSubstances
(RoHS)inElectricalandElectronicEquipment.
InaccordancewithDirective2002/96/ECoftheEuropeanParliamentonwasteelectricalandelectronicequipment
(WEEE):
1.
Thesymbolaboveindicatesthatseparatecollectionofelectricalandelectronicequipmentisrequiredandthatthis
productwasplacedontheEuropeanmarketafterAugust13,2005,thedateofenforcementforDirective
2002/96/EC.
2. Whenthisproducthasreachedtheendofitsserviceablelife,itcannotbedisposedofasunsortedmunicipalwaste.
Itmustbecollectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthattherearepotentialnegativeeffectsontheenvironment
andhumanhealthasaresultofthepresenceofhazardoussubstancesinelectricalandelectronicequipment.
4.
ItistheusersresponsibilitytoutilizetheavailablecollectionsystemtoensureWEEEisproperlytreated.
Forinformationabouttheavailablecollectionsystem,pleasegotohttp://www.enterasys.com/services/support/or
contactEnterasysCustomerSupportat35361705586(Ireland).
iii
Supplement to Product Instructions
(Parts)
(Metal Parts)
(Circuit Modules)
(Circuit Breakers)
3E
(Hazardous Substance)
+J
&G
&U
3%%
3%'(
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h
SJ/T 11363-2006
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
This table shows where these substances may be found in the supply chain of Enterasys electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
iv
50
VCCI NOTICE
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformation
TechnologyEquipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.
Whensuchtroubleoccurs,theusermayberequiredtotakecorrectiveactions.
DECLARATION OF CONFORMITY
ApplicationofCouncilDirective(s):
ManufacturersName:
ManufacturersAddress:
EuropeanRepresentativeAddress:
ConformancetoDirective(s)/ProductStandards:
EquipmentType/Environment:
89/336/EEC
73/23/EEC
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
USA
Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ECDirective89/336/EEC
EN55022
EN6100032
EN6100033
EN55024
ECDirective73/23/EEC
EN60950
NetworkingEquipment,foruseinaCommercial
orLightIndustrialEnvironment.
vi
vii
3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateand
federalcourtsoftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youacceptthe
personaljurisdictionandvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNations
ConventionontheLimitationPeriodintheInternationalSaleofGoods,andtheUniformComputerInformation
TransactionsActshallapplytothisAgreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubjecttoregulationbyagencies
oftheU.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertain
technicalproductstocertaincountries,unlessalicensetoexporttheproductisobtainedfromtheU.S.Governmentor
anexceptionfromobtainingsuchlicensemayberelieduponbytheexportingparty.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusethe
Programforcivilendusesonlyandnotformilitarypurposes.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSection1or2ofthisAgreement,You
agreenotto(i)reexportorreleasetheProgram,thesourcecodefortheProgramortechnologytoanationalofa
countryinCountryGroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Cambodia,Cuba,Georgia,Iraq,
Kazakhstan,Laos,Libya,Macau,Moldova,Mongolia,NorthKorea,thePeoplesRepublicofChina,Russia,Tajikistan,
Turkmenistan,Ukraine,Uzbekistan,Vietnam,orsuchothercountriesasmaybedesignatedbytheUnitedStates
Government),(ii)exporttoCountryGroupsD:1orE:2(asdefinedherein)thedirectproductoftheProgramorthe
technology,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrolsasidentifiedontheU.S.
CommerceControlList,or(iii)ifthedirectproductofthetechnologyisacompleteplantoranymajorcomponentofa
plant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantoramajorcomponentthereof,ifsuch
foreignproduceddirectproductissubjecttonationalsecuritycontrolsasidentifiedontheU.S.CommerceControl
ListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyat
privateexpense;(ii)containsrestrictedcomputersoftwaresubmittedwithrestrictedrightsinaccordancewithsection
52.22719(a)through(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)in
allrespectsisproprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,the
ProgramisconsideredcommercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,
anduse,duplication,ordisclosurebytheU.S.Governmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUIN
WRITINGBYENTERASYS,ENTERASYSDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,
INCLUDINGBUTNOTLIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORY
QUALITY,FITNESSFORAPARTICULARPURPOSE,TITLEANDNONINFRINGEMENTWITHRESPECTTOTHE
PROGRAM.IFIMPLIEDWARRANTIESMAYNOTBEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIED
WARRANTIESARELIMITEDINDURATIONTOTHIRTY(30)DAYSAFTERDELIVERYOFTHEPROGRAMTO
YOU.
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITSSUPPLIERSBELIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,
PROFITS,BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,
CONSEQUENTIAL,ORRELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTO
USETHEPROGRAM,EVENIFENTERASYSHASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES.
THISFOREGOINGLIMITATIONSHALLAPPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICH
DAMAGESARESOUGHT.
THECUMULATIVELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,
INCONTRACT,TORTOROTHERWISE,SHALLNOTEXCEEDTHETOTALAMOUNTOFFEESPAIDTO
ENTERASYSBYYOUFORTHERIGHTSGRANTEDHEREIN.
viii
8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramare
ofcriticalvaluetoEnterasys,and,accordingly,Youherebyagreetomaintaincompletebooks,recordsandaccounts
showing(i)licensefeesdueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.Youalsograntto
Enterasysanditsauthorizedrepresentatives,uponreasonablenotice,therighttoauditandexamineduringYour
normalbusinesshours,Yourbooks,records,accountsandhardwaredevicesuponwhichtheProgrammaybedeployed
toverifycompliancewiththisAgreement,includingtheverificationofthelicensefeesdueandpaidEnterasysandthe
use,copyinganddeploymentoftheProgram.Enterasysrightofexaminationshallbeexercisedreasonably,ingood
faithandinamannercalculatedtonotunreasonablyinterferewithYourbusiness.Intheeventsuchauditdiscovers
noncompliancewiththisAgreement,includingcopiesoftheProgrammade,usedordeployedinbreachofthis
Agreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasysreservestheright,tobe
exercisedinitssolediscretionandwithoutpriornotice,toterminatethislicense,effectiveimmediately,forfailureto
complywiththisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshall
returntoEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.Youacknowledgeandagreethatthe
Programconstitutestradesecretsand/orcopyrightedmaterialofEnterasysand/oritssuppliers.Youagreeto
implementreasonablesecuritymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleand
interestinandtotheProgramshallremainwithEnterasysand/oritssuppliers.Allrightsnotspecificallygrantedto
YoushallbereservedtoEnterasys.
10. ENFORCEMENT. YouacknowledgeandagreethatanybreachofSections2,4,or9ofthisAgreementbyYoumay
causeEnterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasys
maybeentitledtoseektimelyinjunctiverelieftoprotectEnterasysrightsunderthisAgreementinadditiontoanyand
allremediesavailableatlaw.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligations
underthisAgreement,exceptthatYoumayassignthisAgreementtoanypersonorentitywhichacquiressubstantially
allofYourstockassets.EnterasysmayassignthisAgreementinitssolediscretion.ThisAgreementshallbebinding
uponandinuretothebenefitoftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsas
permittedbythisAgreement.Anyattemptedassignment,transferorsublicenseinviolationofthetermsofthis
AgreementshallbevoidandabreachofthisAgreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbein
writingandwillnotbeconstruedasawaiverofanysubsequentbreachofsuchtermorcondition.Enterasysfailureto
enforceatermuponYourbreachofsuchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcement
onanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,the
validity,legalityandenforceabilityofanyoftheremainingprovisionsshallnotinanywaybeaffectedorimpaired
thereby,andthatprovisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuch
invalidity,illegality,orunenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalorunenforceablesuch
provisioninanyotherjurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyuponYourbreachofanyoftheterms
andconditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramand
shallreturntoEnterasystheProgramandallcopiesoftheProgram.
ix
Contents
About This Guide
Who Should Use This Guide ...............................................................................................................xiii
How to Use This Guide ...................................................................................................................... xiv
Related Documents ........................................................................................................................... xiv
Getting Help ....................................................................................................................................... xvi
Chapter 1: Introduction
Overview of DFE-Platinum Series Capabilities ..................................................................................1-1
DFE-Platinum Module ........................................................................................................................1-2
Connectivity .......................................................................................................................................1-4
Management ......................................................................................................................................1-4
Switch Configuration Using WebView .........................................................................................1-4
Switch Configuration Using CLI Commands ...............................................................................1-4
Standards Compatibility .....................................................................................................................1-4
LANVIEW Diagnostic LEDs ...............................................................................................................1-4
Chapter 3: Installation
Unpacking the DFE-Platinum Module ................................................................................................3-2
Backplane Connections and Installation Rules ..................................................................................3-2
FTM1 and FTM2 Connectivity .....................................................................................................3-2
Module Placement and Rules ......................................................................................................3-3
Installing Module into a Matrix E7 or Matrix N7 Chassis ....................................................................3-6
Preparation ..................................................................................................................................3-6
Installation ...................................................................................................................................3-7
Installing Module into Matrix N3 Chassis ...........................................................................................3-9
Connecting to the Network ...............................................................................................................3-11
Connecting UTP Cables to 7H4202-72 .....................................................................................3-11
Connecting to COM Port for Local Management .............................................................................3-15
What Is Needed .........................................................................................................................3-15
Connecting to an IBM PC or Compatible Device .......................................................................3-16
Connecting to a VT Series Terminal ..........................................................................................3-17
Connecting to a Modem ............................................................................................................3-18
Adapter Wiring and Signal Assignments ...................................................................................3-20
Completing the Installation ...............................................................................................................3-21
Completing the Installation of a New System ............................................................................3-21
Completing the Installation in an Existing System .....................................................................3-23
xi
Chapter 4: Troubleshooting
Using LANVIEW .................................................................................................................................4-1
Troubleshooting Checklist ..................................................................................................................4-5
Overview of DFE-Platinum Module Shutdown Procedure .................................................................4-7
Recommended Shutdown Procedure Using OFFLINE/RESET Switch .......................................4-8
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch .............................................4-8
Appendix A: Specifications
DFE-Platinum Module Specifications ................................................................................................ A-1
COM Port Pinout Assignments ......................................................................................................... A-2
Regulatory Compliance ..................................................................................................................... A-3
Tables
3-1
4-1
4-2
A-1
A-2
A-3
xii
Important Notice
Depending on the firmware version used in the DFE-Platinum module, some features described in
this document may not be supported. Refer to the Release Notes shipped with the DFE-Platinum
module to determine which features are supported.
Thisguideisintendedforanetworkadministratorresponsibleforinstallingandsetting
uptheDFEPlatinummodule.
xiii
Refer to...
Chapter 1, Introduction
Chapter 3, Installation
Chapter 4, Troubleshooting
Appendix A, Specifications
Related Documents
ThemanualslistedbelowcanbeobtainedfromtheWorldWideWebinAdobeAcrobat
PortableDocumentFormat(PDF)atthefollowingsite:
http://www.enterasys.com/support/manuals
EnterasysMatrixDFEPlatinumSeriesConfigurationGuideprovidesinformationon
howtousetheCommandLineInterfacetosetupandmanagetheDFEPlatinum
modules.
CablingGuideprovidesinformationondBlossandcablespecifications.
UnliketheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide,theCabling
Guideisnotlistedalphabeticallyonthewebsite.Instead,itislistedunderthe
OverviewGuideslink.
xiv
Related Documents
Indicates a hypertext link. When reading this document online, click the text in blue to
go to the referenced figure, table, or section.
Note: Calls the readers attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaucin: Contiene informacin esencial para prevenir daar el equipo.
Achtung: Verweit auf wichtige Informationen zum Schutz gegen Beschdigungen.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una accin que pudiera resultar en lesin corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfllen fhren knnen!
Electrical Hazard: Warns against an action that could result in personal injury or
death.
Riesgo Electrico: Advierte contra una accin que pudiera resultar en lesin corporal
o la muerte debido a un riesgo elctrico.
Elektrischer Gefahrenhinweis: Warnung vor smtlichen Handlungen, die zu
Verletzung von Personen oder Todesfllen hervorgerufen durch elektrische
Spannung fhren knnen!
Lowercasex:Indicatesthegeneraluseofanalphanumericcharacter(e.g.,6x1xx,thexs
indicateacombinationofnumbersorletters).
xv
Getting Help
Getting Help
Foradditionalsupportrelatedtothemoduleorthisdocument,contact
Enterasys Networksusingoneofthefollowingmethods:
World Wide Web
www.enterasys.com/services/support/
Phone
Internet mail
support@enterasys.com
To expedite your message, type [SWITCHING] in the subject line.
BeforecontactingEnterasys Networksfortechnicalsupport,havethefollowing
informationready:
xvi
YourEnterasys Networksservicecontractnumber
Adescriptionofthefailure
Adescriptionofanyaction(s)alreadytakentoresolvetheproblem(forexample,
changingmodeswitches,rebootingtheunit)
TheserialandrevisionnumbersofallinvolvedEnterasys Networksproductsinthe
network
Adescriptionofyournetworkenvironment(forexample,layoutandcabletype)
Networkloadandframesizeatthetimeoftrouble(ifknown)
Thedevicehistory(forexample,haveyoureturnedthedevicebefore,isthisa
recurringproblem)
AnypreviousReturnMaterialAuthorization(RMA)numbers
1
Introduction
ThischapterprovidesanoverviewoftheDFEPlatinumseriesmodulescapabilities,and
introducesthe7H420272DFEPlatinummodule.
Superiorperformanceandcapacitytosupportmorehighbandwidthandlatency
sensitiveapplications
10/100/1000BaseTXand10GigabitEthernetconnectivity
IntegratedServicesDesignthatreducesthenumber/typeofmodulesrequired,
simplifiesnetworkdesign,andlowersentrycost
PortandUserBasedPolicyandMultilayerPacketClassificationthatprovides
granularcontrolandsecurityforbusinesscriticalapplications
Highavailabilityserviceswithstatefulfailoverforservicesandmanagement
Selflearningconfigurationmoduleswithincreasedreliabilityandfaulttolerancethat
reducesconfigurationtimeandmaximizesuptime
Networkwideconfiguration,change,andinventorymanagementthatiseasierto
install,troubleshoot,andmaintain
Reducedsupportandmaintenancecosts,anddecreasedconfigurationtime
SupportforavarietyofconvergedapplicationsincludingVoIPwithPowerover
Ethernet
1-1
DFE-Platinum Module
DFE-Platinum Module
Thissectionprovidesanoverviewofthe7H420272DFEPlatinummoduleshownin
Figure 11.Forinformationaboutthe7H420272featuresandhowtoconfigurethem,
refertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.
7H4202-72
The7H420272DFEPlatinummodulehas72,10BASET/100BASETXcompliantports,
viafixedfrontpanelRJ45connectors.The7H420272canbeinstalledinaMatrix E7,
Matrix N7,orMatrix N3chassis.
Eachofthefixedfrontpanelportscanoperateineitherhalfduplexorfullduplexmode
ofoperation.Theduplexmodecanbedeterminedbyeitherautonegotiationormanual
configuration.
TheDFEPlatinummoduleportscanbeconfiguredtocontroltrafficbylimitingtherateof
trafficacceptedintothemoduleandprioritizingtraffictoexpeditetheflowofhigher
prioritytrafficthroughthemoduleinasecuremanor.
TheDFEPlatinummodulereceivespowerandbackplaneconnectivitywhenitisinserted
intotheMatrix E7,Matrix N7,orMatrix N3chassis.
1-2
Introduction
DFE-Platinum Module
Figure 1-1
COM
CPU
MGMT
1X
GROUP 1
GROUP 2
6X
7X
12X
13X
18X
19X
24X
1 2 3
DFE
1
2
3
4
5
OFFLINE/RESET switch
RJ45 COM (Console Port)
CPU LED
MGMT LED
Group 3, 20 Ports, 10/100 Mbps, via RJ45s
GROUP
SELECT
6
7
8
9
GROUP LEDs
GROUP SELECT button
GROUP status LEDs
Groups 1&2, 40 Ports, 10/100 Mbps, via RJ45s
1-3
Connectivity
Connectivity
The7H420272cansupportupto72,10BASET/100BASETXswitchedportsconnected
through72fixedfrontpanelconnectors.
Management
Managementofthemodulecanbeeitherinbandoroutofband.Inbandremote
managementispossibleusingTelnet,Enterasys NetworksNetSightmanagement
application,orWebViewapplication.Outofbandmanagementisprovidedthrough
theRJ45COM(Communication)portonthefrontpanelusingaVT100terminalora
VT100terminalemulator.
Standards Compatibility
TheDFEPlatinummodulesarefullycompliantwiththeIEEE802.32002,802.3ae2002,
802.1D1998,and802.1Q1998standards.TheDFEPlatinummoduleprovidesIEEE
802.1D1998SpanningTreeAlgorithm(STA)supporttoenhancetheoverallreliabilityof
thenetworkandprotectagainstloopconditions.
1-4
Introduction
2
Network Requirements
Beforeinstallingthemodule,reviewtherequirementsandspecificationsreferredtoin
thischapterconcerningthefollowing:
For information about...
Refer to page...
10BASE-T Network
2-1
100BASE-TX Network
2-2
Thenetworkinstallationmustmeettherequirementstoensuresatisfactoryperformance
ofthisequipment.Failuretodosowillproducepoornetworkperformance.
Note: The Enterasys Matrix DFE-Platinum Series Configuration Guide and the Cabling
Guide referred to in the following sections can be found on the Enterasys Networks World
Wide Web site: http://www.enterasys.com/
Refer to Related Documents on page xiv.
10BASE-T Network
Whenconnectinga10BASETsegmenttoanyofthemodulefixedfrontpanelportsofthe
7H420272, ensurethatthenetworkmeetstheEthernetnetworkrequirementsofthe
IEEE 802.32002standardfor10BASET.RefertotheCablingGuidefordetails.
Note: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3
cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 or
Category 5 cabling can be used. Refer to 100BASE-TX Network on page 2-2 for
information about 100BASE-TX networks and cabling.
2-1
100BASE-TX Network
100BASE-TX Network
Fixedfrontpanelportsofthe7H420272 provideaconnectionthatsupportsCategory5
UTPcabling.ThedeviceattheotherendofthetwistedpairsegmentmustmeetIEEE
802.32002100BASETXFastEthernetnetworkrequirementsforthedevicestooperateat
100 Mbps.RefertotheCablingGuidefordetails.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance
between 85 and 111 ohms for 100 Mbps operation.
The module is capable of operating at either 10 or 100 Mbps. The module automatically
senses the speed of the other device and adjusts its speed accordingly.
2-2
Network Requirements
3
Installation
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Elctrico: Solamente personal calificado debe realizar procedimientos de
instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.
Important Notice
Read the Release Notes shipped with the DFE-Platinum module to check for any exceptions to the
supported features and operation documented in this guide.
Thischapterprovidestheinstructionstoinstallthe7H420272DFEPlatinummodule.
Followtheorderofthesectionslistedbelowtocorrectlyinstallthemodule.
For information about...
Refer to page...
3-2
3-2
3-6
3-9
3-11
3-15
3-21
3-1
OpentheboxandremovethepackingmaterialprotectingtheDFEPlatinummodule.
2.
VerifythecontentsofthecartonaslistedinTable 31.
Table 3-1
Item
Quantity
Installation Guide
3.
RemovethetapesealonthenonconductivebagtoremovetheDFEPlatinum
module.
theFrameTransferMatrixFTM1andFTM2backplaneconnections,
thehardwareconfigurationruleswheninstallingfirst(6x1xx),second(6x2xx),and
third(6x3xx)generationmodules,andDFEPlatinummodules(7x4xxx)intothesame
MatrixE7chassis.
3-2
Installation
TheFTMbridgingmoduleshaveconnectionstobothFTM1andFTM2backplanes,which
enablesthemtoswitchframesbetweenthetwobackplanesandallmodulesinthe6C107
chassis.However,theolderfirst(6x1xx),second(6x2xx),andthird(6x3xx)generation
modulesarestillmanagedusingtheirownLocalManagementandarenotsubjectto
managementbytheDFEPlatinummodulemanagemententity.
TheMatrixN3(7C103)andMatrixN7(7C107)chassishaveonlyFTM2connectionsto
supportDFEPlatinummodulesorDFEGoldmodules(notdiscussedinthisbook).
Note: The Matrix N3 (7C103) and Matrix N7 (7C107) chassis will support either
DFE-Platinum modules or DFE-Gold modules, but not in the same chassis.
3-3
Figure 3-1
7XXXXX
6X3XX
1 2 3 4 5 6 7
1 2 3 4 5 6 7
6X1XX
6X2XX
1 2 3 4 5 6 7
D
6X1XX
6X2XX
+
6X3XX 6X3XX
1 2 3 4 5 6 7
7H4202-72 7XXXXX
6X2XX
6X1XX
6X2XX
6X3XX
7XXXXX 6X3XX
1 2 3 4 5 6 7
6X1XX
6X3XX
6X3XX
1 2 3 4 5 6 7
3-4
Installation
3-5
Preparation
3-6
Installation
1.
Removetheblankpanelcoveringthechassisslotinwhichthemodulewillbe
installed.Allotherslotsmustremaincoveredtoensureproperairflowforcooling.
(Savetheblankplateintheeventyouneedtoremovethemodule.)
2.
Removethemodulefromtheshippingbox.(Savetheboxandpackingmaterialsin
theeventthemoduleneedstobereshipped.)
3.
Locatetheantistaticwriststrapshippedwiththechassis.Attachtheantistaticwrist
straptoyourwristandplugthecablefromtheantistaticwriststrapintotheESD
groundingreceptacleattheupperrightcornerofthechassis.
4.
Removethemodulefromtheplasticbag.(Savethebagintheeventthemodulemust
bereshipped.)ObserveallprecautionstopreventdamagefromElectrostatic
Discharge(ESD).
5.
Examinethemodulefordamage.Ifanydamageexists,DONOTinstallthemodule.
ImmediatelycontactEnterasysNetworks.RefertoLANVIEWdiagnosticLEDsserve
asanimportanttroubleshootingaidbyprovidinganeasywaytoobservethestatusof
individualportsandoverallnetworkoperations.onpage 14.
Installation
Toinstallthemodule,refertoFigure 32andproceedasfollows:
Caution: To prevent damaging the backplane connectors in the following step, take care
that the module slides in straight and properly engages the backplane connectors.
Ensure that the top lever lines up with the desired slot number located on the front panel of
the chassis. Refer to Figure 3-2.
Precaucin: Para evitar que se daen los conectores del panel posterior en el siguiente
paso, intente deslizar el mdulo en forma recta y verifique que se enganche
correctamente en los conectores de panel posterior.
Asegrese de que la palanca superior est alineada con respecto al nmero de ranura
correspondiente ubicado en el panel frontal del chasis. Consulte en Figure 3-2.
1.
Locatethechassiscardguidesthatlineupwiththeslotnumberinwhichthemodule
willbeinstalled.(Inthisexample,slot1isbeingused.)Makesurethemodulelocking
leversareintheopenposition(topandbottom).
3-7
Figure 3-2
SERIES
E7
7
FAST ENET
7H4202-72
COM
OFFLINE / RESET
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
6X
7X
12X
13X
18X
19X
24X
GROUP
DFE
1 2 3
GROUP
SELECT
ACON
1
POWER
LINE
100-125V~12A
200-240V~6A
50/60Hz
FAN
ACON
1
POWER
LINE
100-125V~12A
200-240V~6A
50/60Hz
FAN
LINE
100-125V~12A
200-240V~6A
50/60Hz
PS1
1
2
3
4
3-8
Installation
Card guides
Slot number 1
Module card
Metal back panel
LINE
100-125V~12A
200-240V~6A
50/60Hz
PS2
2.
Alignthemodulecardbetweentheupperandlowercardguidesofthedesiredslot
andslideitintothechassis,takingcarethatthemoduleslidesinstraight.SeeCaution
below.
Caution: Due to the amount of force needed to properly seat the module connectors into
the backplane connectors, it is best to apply force to the end of the levers to insert (or
eject) the module. Otherwise, damage could result to the module and chassis.
Precaucin: Para colocar los conectores del mdulo en los conectores del panel
posterior correctamente es necesario hacer bastante fuerza, por ello, para insertar o
quitar el mdulo, se recomienda concentrar la fuerza en el extremo de las palancas. Si no
lo hace, podra daar el mdulo y el chasis.
3.
Slidethemoduleintotheslotuntilyoucanengagethetopandbottomlockinglevers
withthechassisasshowninFigure 32.
Caution: In step 4, do not force the locking levers to the point that they touch the face of
the front panel. Forcing the locking levers to this point could damage the module and
chassis.
Precaucin: En el paso 4, tenga cuidado de no llevar las palancas de cierre a un punto
en donde estn en contacto con el panel frontal. Si lo hace, podra daar el mdulo y/o el
chasis.
4.
RefertotheCautionnoteabove,thenrotatethetwoleversintotheclosedposition.
5.
Ifthechassisinwhichthemoduleisinstalledwaspowereddownfortheinstallation,
turnthepowersupplieson.ChecktoseethatthemoduleCPULEDsettlesatsolid
greenafterafewminutes.IftheLEDdoesnotturnsolidgreen,refertoChapter 4for
troubleshootingdetails.
3-9
Figure 3-3
1 2 3
GROUP
DFE
24X
19X
18X
13X
12X
REDUNDANCY
7X
1X
PWR
6X
COM
GROUP 3
CPU
MGMT
GROUP 2
OFFLINE / RESET
7H4202-72
GROUP 1
FAST ENET
7C203-1
GROUP
SELECT
100-125V~12.0A
200-240V~6.0A
50/60 Hz
7C203-1
PWR
REDUNDANCY
100-125V~12.0A
200-240V~6.0A
50/60 Hz
1
2
3
4
3-10
Installation
Card guides
Slot 1 (Top slot is slot 3.)
Module card
Metal back panel
Inthisprocedure,the7H420272isusedastheexampletoconnectatwistedpairsegment
tothemodule.RefertoFigure 34andproceedasfollows:
1.
EnsurethatthedeviceconnectedtotheotherendofthesegmentispoweredON.
2.
ConnectthetwistedpairsegmenttothemodulebyinsertingtheRJ45connectoron
thetwistedpairsegmentintotheappropriateRJ45portconnector.
3-11
Figure 3-4
FAST ENET
7H4202-72
COM
OFFLINE / RESET
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
RX
TX
24X
GROUP
DFE
1 2 3
GROUP
SELECT
7X
1 RJ45 connector
3.
VerifythatalinkexistsbycheckingthattheportRX(Receive)LEDisON(flashing
amber,blinkinggreen,orsolidgreen).IftheRXLEDisOFFandtheTX(Transmit)
LEDisnotblinkingamber,performthefollowingstepsuntilitison:
a.
Toviewthereceiveandtransmitactivityonagroupofsegments,pressthe
GROUPSELECTbutton(referbacktoFigure 34)tosteptothegroupofinterest
(Groups1through3).EachtimetheGROUPSELECTbuttonispressed,the
GROUPLEDlightsupinsequence,indicatingwhichGroupisselected.The
receiveandtransmitactivityforthatgroupofsegmentsisthenindicatedbythe
RXandTXLEDsforeachsegment.
b.
VerifythatthecablingbeingusedisCategory5UTPwithanimpedancebetween
85and111 ohms.Iftheportistooperateat100 Mbps,category 5cablingmustbe
used.
c.
Verifythatthedeviceattheotherendofthetwistedpairsegmentisonand
properlyconnectedtothesegment.
d. VerifythattheRJ45connectorsonthetwistedpairsegmenthavetheproper
pinoutsandcheckthecableforcontinuity.Typically,acrossovercableisused
betweenhubdevices.Astraightthroughcableisusedtoconnectbetween
switchesorhubdevicesandanenduser(computer).RefertoFigure 35and
Figure 36forfourwireRJ45connections.RefertoFigure 37andFigure 38for
eightwireRJ45connections.
3-12
Installation
Figure 3-5
Devices
RX+
RX+
RX
RX
TX+
TX+
TX
TX
RX+
RX+
RX
RX
TX+
TX+
TX
TX
3-13
Figure 3-7
Devices
TX1+
TX2+
RX1-
RX2-
TX2+
TX1+
TX3+
TX4+
RX3-
RX4-
RX2-
RX1-
TX4+
TX3+
RX4-
RX3-
TX1+
TX2+
RX1-
RX2-
TX2+
TX1+
TX3+
TX4+
RX3-
RX4-
RX2-
RX1-
TX4+
TX3+
RX4-
RX3-
3-14
Installation
e.
EnsurethatthetwistedpairconnectionmeetsthedBlossandcablespecifications
outlinedintheCablingGuide.RefertoRelatedDocumentsonpage xivfor
informationonobtainingthisdocument.
Ifalinkisnotestablished,contactEnterasysNetworks.RefertoLANVIEW
diagnosticLEDsserveasanimportanttroubleshootingaidbyprovidinganeasyway
toobservethestatusofindividualportsandoverallnetworkoperations.onpage 14
fordetails.
4.
Repeatsteps1through3above,untilallconnectionshavebeenmade.
Thissectionalsoprovidesthepinoutassignmentsoftheadapters.
What Is Needed
Thefollowingisalistoftheusersuppliedpartsthatmaybeneededdependingonthe
connection:
RJ45toDB9femaleadapter
UTPstraightthroughcablewithRJ45connectors
RJ45toDB25femaleadapter
RJ45toDB25maleadapter
WithaUTPstraightthroughcablewithRJ45connectorsandRJ45toDB9adapter,you
canconnectproductsequippedwithanRJ45COMporttoanIBMorcompatiblePC
runningaVTseriesemulationsoftwarepackage.
WithaUTPstraightthroughcableandRJ45toDB25femaleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaVTseriesterminalorVTtypeterminals
runningemulationprogramsfortheVTseries.
WithaUTPstraightthroughcableandanRJ45toDB25maleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaHayescompatiblemodemthatsupports
9600 baud.
3-15
ConnecttheRJ45connectoratoneendofaUTPstraightthroughcabletothe
communicationsCOMportontheEnterasys Networksmodule.(TheCOMportis
alsoknownasaConsoleport.)
2.
PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintoan
RJ45toDB9femaleadapter.
3.
ConnecttheRJ45toDB9femaleadaptertothecommunicationsportontheIBMPC.
4.
TurnonthePCandconfigureyourVTemulationpackagewiththefollowing
parameters:
Parameter
Setting
Mode
7 Bit Control
Transmit
Transmit=9600
Bits Parity
8 Bits, No Parity
Stop Bit
1 Stop Bit
Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheappropriateEnterasysMatrixDFEPlatinumSeriesConfigurationGuidefor
furtherinformation.
3-16
Installation
Figure 3-9
FAST ENET
7H4202-72
COM
OFFLINE / RESET
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
1
2
ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletotheCOM
portontheEnterasys Networksmodule.
2.
PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25femaleadapter.
3.
ConnecttheRJ45toDB25adaptertotheportlabeledCOMMontheVTterminal.
4.
TurnontheterminalandaccesstheSetupDirectory.Setthefollowingparameterson
yourterminal:
Parameter
Setting
Mode
7 Bit Control
Transmit
Transmit=9600
Bits Parity
8 Bits, No Parity
Stop Bit
1 Stop Bit
3-17
Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Figure 3-10
FAST ENET
7H4202-72
OFFLINE / RESET
COM
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
Connecting to a Modem
ToconnectamodemtoanEnterasys NetworksDFEPlatinummoduleCOMport
(Figure 311),useaUTPstraightthroughcablewithRJ45connectorsandanRJ45toDB25
maleadapter,andproceedasfollows:
3-18
Installation
1.
ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletotheCOM
portoftheDFE module.
2.
PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25maleadapter.
3.
ConnecttheRJ45toDB25adaptertothecommunicationsportonthemodem.
4.
Turnonthemodem.
5.
WithaPCconnectedtoaremotemodem,youcanconfiguretheswitchremotely.To
accomplishthis,youmustconfigureyourPCVTemulationpackagewiththe
followingparameters.
Parameter
Setting
Mode
7 Bit Control
Transmit
Transmit=9600
Bits Parity
8 Bits, No Parity
Stop Bit
1 Stop Bit
Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Figure 3-11
Connecting to a Modem
FAST ENET
7H4202-72
OFFLINE / RESET
COM
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
4 Local modem
5 Remote modem
3-19
DB9
Pin
Conductor
Pin
Signal
Blue
Receive (RX)
Red
Transmit (TX)
Green
Ground (GRD)
Orange
Yellow
Pins
Pins
9
6
DB9 Connector (Female)
DB25
Pin
Conductor
Pin
Signal
Red
Transmit (TX)
Blue
Receive (RX)
Yellow
Green
Ground (GRD)
Orange
20
Pins
13
25
3-20
Installation
Pins
14
DB25
Pin
Conductor
Pin
Signal
Blue
Transmit (TX)
Orange
Red
Receive
Green
Ground (GRD)
Yellow
20
Gray
22
Ring Indicator
Pins
Pins
14
13
25
anewDFEPlatinummodulesystem(refertoCompletingtheInstallationon
page 321),or
anestablished,operatingDFEPlatinummodulesystem(refertoCompletingthe
InstallationinanExistingSystemonpage 323).
3-21
StarttheCommandLineInterface(CLI)fromthemoduleslocalconsoleportasfollows:
1.
ConnectaterminaltothelocalconsoleportasdescribedinConnectingtoCOMPort
forLocalManagementonpage 315.Thestartupscreen,Figure 312,displays.
2.
Attheloginprompt,enteroneofthefollowingdefaultusernames:
roforReadOnlyaccess,
rwforReadWriteaccess,or
adminforSuperUseraccess.(ThisaccesslevelallowsReadWriteaccesstoall
modifiableparameters,includinguseraccounts.)
3.
PressENTER.
4.
ThePasswordpromptdisplays.LeavethisstringblankandpressENTER.The
moduleinformationandMatrixpromptdisplaysasshowninFigure 312.
TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEPlatinum
management,refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfiguration
Guide.TheCLIcommandsenableyoutoinitiallysetupandperformmoreinvolved
managementconfigurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inLANVIEWdiagnosticLEDsserveasanimportanttroubleshootingaidbyproviding
aneasywaytoobservethestatusofindividualportsandoverallnetworkoperations.on
page 14.
3-22
Installation
Figure 3-12
login: admin
Password:
M A T R I X N7
Command Line Interface
Enterasys Networks, Inc.
50 Minuteman Rd.
Andover, MA 01810-1008 U.S.A.
Phone: +1 978 684 1000
E-mail: support@enterasys.com
WWW:
http://www.enterasys.com
(c) Copyright Enterasys Networks, Inc. 2003
Chassis Serial Number:
xxxxxxxxxxxx
Chassis Firmware Revision: xx.xx.xx
Matrix N7(su)->
aDFEPlatinummoduleisalreadyestablishedasthemanagementmodule,
thepasswordshavealreadybeensetforvarioususers,
thesystemIPaddressisset,and
othersystemparametershavebeenset.
WhenyouinstallanewDFEPlatinummoduleintoasystemwithanexistingconfigured
useraccount,thecurrentsystemsettingsinthataccountarealreadyrecognizedbythe
newDFEPlatinummoduleanditwilloperateaccordingly.
Ifyouneedtochangeanysettings,youcanconnectaterminaltothelocalconsoleportas
describedinConnectingtoCOMPortforLocalManagementonpage 315toaccess
systemmanagement,oruseaTelnetconnectiontoaccesstheDFEPlatinummodule
systemmanagementasdescribedinChapter3oftheEnterasysMatrixDFEPlatinumSeries
ConfigurationGuide.
3-23
Attheloginprompt,enteryouradministrativelyassignedusernameandpress
ENTER.
2.
AtthePasswordprompt,enteryourpasswordandpressENTER.
ThenoticeofauthorizationandtheMatrixpromptdisplaysasshownbackinFigure 312.
Note: Users with Read-Write (rw) and Read-Only access can use the set password
commandtochange their own passwords. Administrators with Super User (su) access
can use the set system login command to create and change user accounts, and the set
password command to change any local account password. For information on the set
password and set system login commands, refer to Chapter 3 in the Enterasys Matrix
DFE-Platinum Series Configuration Guide.
TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEPlatinum
management,refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfiguration
Guide.TheCLIcommandsenableyoutoinitiallysetupandperformmoreinvolved
managementconfigurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inGettingHelponpage xvi.
3-24
Installation
4
Troubleshooting
Thischapterprovidesinformationconcerningthefollowing:
For information about...
Refer to page...
Using LANVIEW
4-1
Troubleshooting Checklist
4-5
4-7
4-8
4-8
Unlessotherwisenoted,thefollowinginformationappliestoallDFEPlatinummodules.
Using LANVIEW
Themodulesuseabuiltinvisualdiagnosticandstatusmonitoringsystemcalled
LANVIEW.TheLANVIEWLEDs(Figure 41)allowquickobservationofthenetwork
statustoaidindiagnosingnetworkproblems.
4-1
Using LANVIEW
LANVIEW LEDs
FAST ENET
7H4202-72
COM
OFFLINE / RESET
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
GROUP 3
RX
TX
24X
GROUP
DFE
1 2 3
GROUP
GROUP
SELECT
7X
1 MGMT LED
1 2 3
GROUP
SELECT
2 Group LEDs
Table 41describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
Note: The terms used in Table 4-1 indicate the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Alternating indicates an LED is flashing in a steady rate other than 50% on, 50% off.
4-2
Troubleshooting
Using LANVIEW
Table 4-1
LANVIEW LEDs
LED
Color
State
Recommended Action
MGMT
None
None.
Green
None.
Amber
Flashing. This is a
temporary indication that the
module is saving data.
None.
None
Power off.
Amber
None.
Solid. Testing.
None.
Solid. Functional.
None.
Red
None.
Green
and
Amber
CPU
Green
4-3
Using LANVIEW
Table 4-1
LED
Color
State
Recommended Action
RX
(Receive)
None
None.
Green
None.
Amber
None.
Red
Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.
None
Green
None.
Red
TX
(Transmit)
4-4
Troubleshooting
Troubleshooting Checklist
Troubleshooting Checklist
Ifthemoduleisnotworkingproperly,refertoTable 42forachecklistofproblems,
possiblecauses,andrecommendedactionstoresolvetheproblem.
Table 4-2
Troubleshooting Checklist
Problem
Possible Cause
Recommended Action
Loss of power.
No Local
Management
Password screen.
Cannot navigate
beyond Password
screen.
Improper username/
password combination
entered.
IP address not
assigned.
Port is disabled.
No link to device.
4-5
Troubleshooting Checklist
Table 4-2
Problem
Possible Cause
Recommended Action
Loop condition
detected.
User parameters
(IP address, device
and module name,
etc.) were lost
when the module
power was cycled,
the front panel
OFFLINE/RESET
switch was
pressed.
4-6
Troubleshooting
Recommendedshutdownprocedure(page48)
Figure 4-2
OFFLINE/RESET Switch
FAST ENET
7H4202-72
OFFLINE / RESET
COM
CPU
MGMT
1X
GROUP 1
GROUP 2
GROUP 3
1 OFFLINE/RESET switch
4-7
BeforepullingaDFEPlatinummoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating
thatthemoduleisshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthemoduleisina
haltstate.Inthistimeitissafetorestartorremovethemodulefromthechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60
secondsfromthetimetheCPUstartsalternatelyflashingamber/offuntilthedevice
automaticallyrestarts.
Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.
ToresetaDFEPlatinummodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEPlatinummoduleoutofthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetopullamoduleoutofthechassisisafterthe
completionofashutdownandthemanagementLEDisalternatelyflashingamber/off.
4-8
Troubleshooting
A
Specifications
Thisappendixprovidesinformationaboutthefollowing:
For information about...
Refer to page...
A-1
A-2
Regulatory Compliance
A-3
EnterasysNetworksreservestherighttochangethespecificationsatanytimewithout
notice.
7H4202-72Specifications
Item
Specification
Ports
Ports 1 through 72
Processors/Memory
Processor
FLASH Memory
32 MB (not upgradeable)
A-1
Table A-1
7H4202-72Specifications (continued)
Item
Specification
Physical
Dimensions
Approximate Weight
For the MTBF hours for these products, refer to the MTBF web
site at http://www.enterasys.com/support/matrix/mtbf.cgi and
search for MTBF.
Environmental
Operating Temperature
Storage Temperature
5% to 90% (non-condensing)
A-2
Specifications
Pin
Signal Name
Input/Output
Output
Input
Input
Input
NA
Output
Output
Input
Regulatory Compliance
Regulatory Compliance
The7H420272meetsthesafetyandelectromagneticcompatibility(EMC)requirements
listedinTable A3:
Table A-3
Compliance Standards
Regulatory Compliance
Standards
Safety
Electromagnetic Compatibility
(EMC)
A-3
Regulatory Compliance
A-4
Specifications
B
Mode Switch Bank Settings
Caution: Read the appropriate sections to be fully aware of the consequences when
changing switch settings.
Only qualified personnel should change switch settings.
Precaucin: Si desea modificar la configuracin del interruptor, lea las secciones
correspondientes para saber cul ser el resultado de hacerlo.
Estas modificaciones a la configuracin slo debe realizarlas personal calificado.
Figure B1showsthelocationofthemodeswitchesandtheswitchsettingsfornormal
operation.Theseswitchesaresetatthefactorytotheoffpositionandrarelyneedtobe
changed.
Switchdefinitionsandpositionsareasfollows:
Switches1through6ForEnterasysNetworksuseonly.
Switch7ClearPersistentData.ChangingthepositionofthisswitchclearsPersistent
Dataonthenextpowerupofthemodule.Alluserenteredparameters,suchastheIP
address,modulenames,etc.,areresettothefactorydefaultsettings.Oncethemodule
resets,youcaneitherusethefactorydefaultsettingsorreenteryourownparameters.
Switch8ClearAdminPassword.Changingthepositionofthisswitchclearsthe
adminpassword,andrestoresthefactorydefaultpasswordonthenextpowerupof
themodule.Oncethemoduleresets,youcaneitherusethefactorydefaultsettingsor
reenteryourownpassword.
Note: Do not change the position of Switch 8 unless it is necessary to reset the admin
password to its factory default setting.
B-1
B-2
DFE
GROUP
SELECT
GROUP
18X
1 2 3
19X
12X
13X
7X
6X
1X
FAST ENET
GROUP 1
GROUP 2
MGMT
CPU
OFFLINE / RESET
7H4202-72
GROUP 3
COM
Figure B-1
Mode Switch Location
1 2 3 4 5 6 7 8
ON
Index
Numerics
100BASE-TX
requirements 2-2
10BASE-T
requirements 2-1
7H4202-72
introduction to 1-2
Installation
connecting to the Network 3-11
module into Matrix E7 or N7 chassis 3-6
module into Matrix N3 chassis 3-9
C
Cable connections
7H4202-72 3-11
Cable specifications
100BASE-TX network 2-2
10BASE-T network 2-1
CLI command
introduction to 1-4
COM port connections
what is needed 3-15
Connecting to the network 3-11
Connectivity
DFE-Platinum module and Ethernet interface
module 1-4
Console port
pinout assignments A-2
D
DFE-Platinum modules and Interface Option
introduction to 1-2
DFE-Platinum series modules
overview of capabilities 1-1
specifications for A-1
E
Electromagnetic Compatibility (EMC)
requirements A-3
G
Getting Help
instructions for xvi
GROUP SELECT button
use of the 4-2
Guide
how to use xiv
L
LANVIEW Diagnostic LEDs
introduction to 1-4
use of 4-1
Local Management
COM port connections 3-15
introduction to 1-4
Login
administratively configured 3-24
M
Management
use of 1-4
Management (MGMT) LED
function of 4-1
Matrix E7 or N7 chassis
module installation into 3-6
Matrix N3 chassis
module installation into 3-9
Module features 1-2
N
Network
connecting to 3-11
Network Requirements
list of 2-1
O
OFFLINE/RESET switch 4-8
P
Pinout assignments
console port A-2
Pinouts
crossover 3-13, 3-14
straight-through 3-13, 3-14
Index-1
Receive LEDs
viewing of 4-2
Regulatory Compliance A-3
Related manuals
obtaining xiv
RESET button. SeeOFFLINE/RESET switch
WebView
introduction to 1-4
T
Transmit LEDs
viewing of 4-2
Troubleshooting 4-1
checklist for 4-5
Index-2
V
Viewing Receive and Transmit Activity
instructions for 4-2