Vous êtes sur la page 1sur 64

7.

5x9-inch cover with bleed on 4 sides

Enterasys Matrix
DFE-Platinum Series

Hardware Installation Guide


7H4202-72

P/N 9033929-02

Electrical Hazard: Only qualified personnel should perform installation procedures.


Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes
Personal vorgenommen werden.

Notice
Enterasys Networksreservestherighttomakechangesinspecificationsandotherinformationcontainedinthis
documentanditswebsitewithoutpriornotice.ThereadershouldinallcasesconsultEnterasys Networksto
determinewhetheranysuchchangeshavebeenmade.
Thehardware,firmware,orsoftwaredescribedinthisdocumentissubjecttochangewithoutnotice.
INNOEVENTSHALLENTERASYS NETWORKSBELIABLEFORANYINCIDENTAL,INDIRECT,SPECIAL,OR
CONSEQUENTIALDAMAGESWHATSOEVER(INCLUDINGBUTNOTLIMITEDTOLOSTPROFITS)ARISING
OUTOFORRELATEDTOTHISDOCUMENT,WEBSITE,ORTHEINFORMATIONCONTAINEDINTHEM,EVEN
IFENTERASYS NETWORKSHASBEENADVISEDOF,KNEWOF,ORSHOULDHAVEKNOWNOF,THE
POSSIBILITYOFSUCHDAMAGES.
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
2007Enterasys Networks, Inc.Allrightsreserved.
PartNumber: 903392902 July2007
ENTERASYS NETWORKS, ENTERASYS MATRIX, LANVIEW, MATRIX, ENTERASYS NETSIGHT, WEBVIEW, and
any logos associated therewith, are trademarks or registered trademarks of Enterasys Networks, Inc., in the United States and
other countries.
Allotherproductnamesmentionedinthismanualmaybetrademarksorregisteredtrademarksoftheirrespective
companies.
DocumentationURL:http://www.enterasys.com/support/manuals
DocumentacionURL:http://www.enterasys.com/support/manuals
DokumentationimInternet:http://www.enterasys.com/support/manuals

REGULATORY COMPLIANCE INFORMATION


FEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICE
ThisdevicecomplieswithPart15oftheFCCrules.Operationissubjecttothefollowingtwoconditions:(1)thisdevice
maynotcauseharmfulinterference,and(2)thisdevicemustacceptanyinterferencereceived,includinginterference
thatmaycauseundesiredoperation.
NOTE: ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaclassAdigitaldevice,pursuantto
Part15oftheFCCrules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferencewhen
theequipmentisoperatedinacommercialenvironment.Thisequipmentuses,generates,andcanradiateradio
frequencyenergyandifnotinstalledinaccordancewiththeoperatorsmanual,maycauseharmfulinterferenceto
radiocommunications.Operationofthisequipmentinaresidentialareaislikelytocauseinterferenceinwhichcase
theuserwillberequiredtocorrecttheinterferenceathisownexpense.
WARNING: Changesormodificationsmadetothisdevicewhicharenotexpresslyapprovedbytheparty
responsibleforcompliancecouldvoidtheusersauthoritytooperatetheequipment.

INDUSTRY CANADA NOTICE


ThisdigitalapparatusdoesnotexceedtheclassAlimitsforradionoiseemissionsfromdigitalapparatussetoutinthe
RadioInterferenceRegulationsoftheCanadianDepartmentofCommunications.
Leprsentappareilnumriquenmetpasdebruitsradiolectriquesdpassantleslimitesapplicablesauxappareils
numriquesdelaclassAprescritesdansleRglementsurlebrouillageradiolectriquedictparleministredes
CommunicationsduCanada.

CLASS A ITE NOTICE


WARNING: ThisisaClassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhich
casetheusermayberequiredtotakeadequatemeasures.

CLASE A. AVISO DE ITE


ADVERTENCIA:EsteesunproductodeClaseA.Enunambientedomsticoesteproductopuedecausarinterferencia
deradioencuyocasopuedeserrequeridotomarmedidasadecuadas.

KLASSE A ITE ANMERKUNG


WARNHINWEIS:DiesesProduktzhltzurKlasseA(Industriebereich).InWohnbereichenkanneshierdurchzu
Funkstrungenkommen,dahersolltenangemesseneVorkehrungenzumSchutzgetroffenwerden.

PRODUCT SAFETY
Thisproductcomplieswiththefollowing:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,IEC60950.

SEGURIDAD DEL PRODUCTO


ElproductodeEnterasyscumpleconlosiguiente:UL60950,CSAC22.2No.60950,73/23/EEC,EN 60950,IEC 60950.

PRODUKTSICHERHEIT
DiesesProduktentsprichtdenfolgendenRichtlinien:UL60950,CSAC22.2No.60950,73/23/EEC,EN60950,
IEC 60950.
ii

ELECTROMAGNETIC COMPATIBILITY (EMC)


Thisproductcomplieswiththefollowing:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,EN6100032,
EN 6100033,EN55024,AS/NZSCISPR22,VCCIV3.

COMPATIBILIDAD ELECTROMGNETICA (EMC)


EsteproductodeEnterasyscumpleconlosiguiente:47CFRPartes2y15,CSAC108.8,89/336/EEC,EN55022,
EN 55024,EN6100032,EN6100033,AS/NZSCISPR22,VCCIV3.

ELEKTRO- MAGNETISCHE KOMPATIBILITT ( EMC )


DiesesProduktentsprichtdenfolgendenRichtlinien:47CFRParts2and15,CSAC108.8,89/336/EEC,EN55022,
EN 6100032,EN6100033,EN55024,AS/NZSCISPR22,VCCIV3.

HAZARDOUS SUBSTANCES
ThisproductcomplieswiththerequirementsofEuropeanDirective,2002/95/EC,RestrictionofHazardousSubstances
(RoHS)inElectricalandElectronicEquipment.

EUROPEAN WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) NOTICE

InaccordancewithDirective2002/96/ECoftheEuropeanParliamentonwasteelectricalandelectronicequipment
(WEEE):
1.

Thesymbolaboveindicatesthatseparatecollectionofelectricalandelectronicequipmentisrequiredandthatthis
productwasplacedontheEuropeanmarketafterAugust13,2005,thedateofenforcementforDirective
2002/96/EC.

2. Whenthisproducthasreachedtheendofitsserviceablelife,itcannotbedisposedofasunsortedmunicipalwaste.
Itmustbecollectedandtreatedseparately.
3. IthasbeendeterminedbytheEuropeanParliamentthattherearepotentialnegativeeffectsontheenvironment
andhumanhealthasaresultofthepresenceofhazardoussubstancesinelectricalandelectronicequipment.
4.

ItistheusersresponsibilitytoutilizetheavailablecollectionsystemtoensureWEEEisproperlytreated.

Forinformationabouttheavailablecollectionsystem,pleasegotohttp://www.enterasys.com/services/support/or
contactEnterasysCustomerSupportat35361705586(Ireland).

iii


Supplement to Product Instructions

(Parts)

(Metal Parts)

(Circuit Modules)


(Cables & Cable Assemblies)



(Plastic and Polymeric parts)

(Circuit Breakers)



3E

(Hazardous Substance)




+J
&G
&U
3%%


3%'(

SJ/T 11363-2006 

Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h

SJ/T 11363-2006 

Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.




This table shows where these substances may be found in the supply chain of Enterasys electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.


 

The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.

iv

50

VCCI NOTICE
ThisisaclassAproductbasedonthestandardoftheVoluntaryControlCouncilforInterferencebyInformation
TechnologyEquipment(VCCI).Ifthisequipmentisusedinadomesticenvironment,radiodisturbancemayarise.
Whensuchtroubleoccurs,theusermayberequiredtotakecorrectiveactions.

BSMI EMC STATEMENT TAIWAN


ThisisaclassAproduct.Inadomesticenvironmentthisproductmaycauseradiointerferenceinwhichcasetheuser
mayberequiredtotakeadequatemeasures.

DECLARATION OF CONFORMITY
ApplicationofCouncilDirective(s):
ManufacturersName:
ManufacturersAddress:

EuropeanRepresentativeAddress:

ConformancetoDirective(s)/ProductStandards:

EquipmentType/Environment:

89/336/EEC
73/23/EEC
Enterasys Networks, Inc.
50MinutemanRoad
Andover,MA01810
USA
Enterasys Networks,Ltd.
NexusHouse,NewburyBusinessPark
LondonRoad,Newbury
BerkshireRG142PZ,England
ECDirective89/336/EEC
EN55022
EN6100032
EN6100033
EN55024
ECDirective73/23/EEC
EN60950
NetworkingEquipment,foruseinaCommercial
orLightIndustrialEnvironment.

Enterasys Networks, Inc.declaresthattheequipmentpackagedwiththisnoticeconformstotheabovedirectives.

vi

ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT


BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
Thisdocumentisanagreement(Agreement)betweentheenduser(You)andEnterasysNetworks,Inc.,onbehalf
ofitselfanditsAffiliates(ashereinafterdefined)(Enterasys)thatsetsforthYourrightsandobligationswithrespect
totheEnterasyssoftwareprogram/firmware(includinganyaccompanyingdocumentation,hardwareormedia)
(Program)inthepackageandprevailsoveranyadditional,conflictingorinconsistenttermsandconditions
appearingonanypurchaseorderorotherdocumentsubmittedbyYou.Affiliatemeansanyperson,partnership,
corporation,limitedliabilitycompany,otherformofenterprisethatdirectlyorindirectlythroughoneormore
intermediaries,controls,oriscontrolledby,orisundercommoncontrolwiththepartyspecified.ThisAgreement
constitutestheentireunderstandingbetweentheparties,withrespecttothesubjectmatterofthisAgreement.The
Programmaybecontainedinfirmware,chipsorothermedia.
BYINSTALLINGOROTHERWISEUSINGTHEPROGRAM,YOUREPRESENTTHATYOUAREAUTHORIZEDTO
ACCEPTTHESETERMSONBEHALFOFTHEENDUSER(IFTHEENDUSERISANENTITYONWHOSEBEHALF
YOUAREAUTHORIZEDTOACT,YOUANDYOURSHALLBEDEEMEDTOREFERTOSUCHENTITY)AND
THATYOUAGREETHATYOUAREBOUNDBYTHETERMSOFTHISAGREEMENT,WHICHINCLUDES,
AMONGOTHERPROVISIONS,THELICENSE,THEDISCLAIMEROFWARRANTYANDTHELIMITATIONOF
LIABILITY.IFYOUDONOTAGREETOTHETERMSOFTHISAGREEMENTORARENOTAUTHORIZEDTO
ENTERINTOTHISAGREEMENT,ENTERASYSISUNWILLINGTOLICENSETHEPROGRAMTOYOUANDYOU
AGREETORETURNTHEUNOPENEDPRODUCTTOENTERASYSORYOURDEALER,IFANY,WITHINTEN
(10)DAYSFOLLOWINGTHEDATEOFRECEIPTFORAFULLREFUND.
IFYOUHAVEANYQUESTIONSABOUTTHISAGREEMENT,CONTACTENTERASYSNETWORKS,LEGAL
DEPARTMENTAT(978)6841000.
YouandEnterasysagreeasfollows:
1. LICENSE. Youhavethenonexclusiveandnontransferablerighttouseonlytheone(1)copyoftheProgram
providedinthispackagesubjecttothetermsandconditionsofthisAgreement.
2. RESTRICTIONS. ExceptasotherwiseauthorizedinwritingbyEnterasys,Youmaynot,normayYoupermitany
thirdpartyto:
(a) Reverseengineer,decompile,disassembleormodifytheProgram,inwholeorinpart,includingforreasons
oferrorcorrectionorinteroperability,excepttotheextentexpresslypermittedbyapplicablelawandtothe
extentthepartiesshallnotbepermittedbythatapplicablelaw,suchrightsareexpresslyexcluded.
InformationnecessarytoachieveinteroperabilityorcorrecterrorsisavailablefromEnterasysuponrequest
anduponpaymentofEnterasysapplicablefee.
(b) IncorporatethePrograminwholeorinpart,inanyotherproductorcreatederivativeworksbasedonthe
Program,inwholeorinpart.
(c) Publish,disclose,copyreproduceortransmittheProgram,inwholeorinpart.
(d) Assign,sell,license,sublicense,rent,lease,encumberbywayofsecurityinterest,pledgeorotherwisetransfer
theProgram,inwholeorinpart.
(e) Removeanycopyright,trademark,proprietaryrights,disclaimerorwarningnoticeincludedonorembedded
inanypartoftheProgram.

vii

3. APPLICABLELAW. ThisAgreementshallbeinterpretedandgovernedunderthelawsandinthestateand
federalcourtsoftheCommonwealthofMassachusettswithoutregardtoitsconflictsoflawsprovisions.Youacceptthe
personaljurisdictionandvenueoftheCommonwealthofMassachusettscourts.Noneofthe1980UnitedNations
ConventionontheLimitationPeriodintheInternationalSaleofGoods,andtheUniformComputerInformation
TransactionsActshallapplytothisAgreement.
4. EXPORTRESTRICTIONS. YouunderstandthatEnterasysanditsAffiliatesaresubjecttoregulationbyagencies
oftheU.S.Government,includingtheU.S.DepartmentofCommerce,whichprohibitexportordiversionofcertain
technicalproductstocertaincountries,unlessalicensetoexporttheproductisobtainedfromtheU.S.Governmentor
anexceptionfromobtainingsuchlicensemayberelieduponbytheexportingparty.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionCIVundertheU.S.Export
AdministrationRegulations,YouagreethatYouareacivilenduseroftheProgramandagreethatYouwillusethe
Programforcivilendusesonlyandnotformilitarypurposes.
IftheProgramisexportedfromtheUnitedStatespursuanttotheLicenseExceptionTSRundertheU.S.Export
AdministrationRegulations,inadditiontotherestrictionontransfersetforthinSection1or2ofthisAgreement,You
agreenotto(i)reexportorreleasetheProgram,thesourcecodefortheProgramortechnologytoanationalofa
countryinCountryGroupsD:1orE:2(Albania,Armenia,Azerbaijan,Belarus,Cambodia,Cuba,Georgia,Iraq,
Kazakhstan,Laos,Libya,Macau,Moldova,Mongolia,NorthKorea,thePeoplesRepublicofChina,Russia,Tajikistan,
Turkmenistan,Ukraine,Uzbekistan,Vietnam,orsuchothercountriesasmaybedesignatedbytheUnitedStates
Government),(ii)exporttoCountryGroupsD:1orE:2(asdefinedherein)thedirectproductoftheProgramorthe
technology,ifsuchforeignproduceddirectproductissubjecttonationalsecuritycontrolsasidentifiedontheU.S.
CommerceControlList,or(iii)ifthedirectproductofthetechnologyisacompleteplantoranymajorcomponentofa
plant,exporttoCountryGroupsD:1orE:2thedirectproductoftheplantoramajorcomponentthereof,ifsuch
foreignproduceddirectproductissubjecttonationalsecuritycontrolsasidentifiedontheU.S.CommerceControl
ListorissubjecttoStateDepartmentcontrolsundertheU.S.MunitionsList.
5. UNITEDSTATESGOVERNMENTRESTRICTEDRIGHTS. TheenclosedProgram(i)wasdevelopedsolelyat
privateexpense;(ii)containsrestrictedcomputersoftwaresubmittedwithrestrictedrightsinaccordancewithsection
52.22719(a)through(d)oftheCommercialComputerSoftwareRestrictedRightsClauseanditssuccessors,and(iii)in
allrespectsisproprietarydatabelongingtoEnterasysand/oritssuppliers.ForDepartmentofDefenseunits,the
ProgramisconsideredcommercialcomputersoftwareinaccordancewithDFARSsection227.72023anditssuccessors,
anduse,duplication,ordisclosurebytheU.S.Governmentissubjecttorestrictionssetforthherein.
6. DISCLAIMEROFWARRANTY. EXCEPTFORTHOSEWARRANTIESEXPRESSLYPROVIDEDTOYOUIN
WRITINGBYENTERASYS,ENTERASYSDISCLAIMSALLWARRANTIES,EITHEREXPRESSORIMPLIED,
INCLUDINGBUTNOTLIMITEDTOIMPLIEDWARRANTIESOFMERCHANTABILITY,SATISFACTORY
QUALITY,FITNESSFORAPARTICULARPURPOSE,TITLEANDNONINFRINGEMENTWITHRESPECTTOTHE
PROGRAM.IFIMPLIEDWARRANTIESMAYNOTBEDISCLAIMEDBYAPPLICABLELAW,THENANYIMPLIED
WARRANTIESARELIMITEDINDURATIONTOTHIRTY(30)DAYSAFTERDELIVERYOFTHEPROGRAMTO
YOU.
7. LIMITATIONOFLIABILITY. INNOEVENTSHALLENTERASYSORITSSUPPLIERSBELIABLEFORANY
DAMAGESWHATSOEVER(INCLUDING,WITHOUTLIMITATION,DAMAGESFORLOSSOFBUSINESS,
PROFITS,BUSINESSINTERRUPTION,LOSSOFBUSINESSINFORMATION,SPECIAL,INCIDENTAL,
CONSEQUENTIAL,ORRELIANCEDAMAGES,OROTHERLOSS)ARISINGOUTOFTHEUSEORINABILITYTO
USETHEPROGRAM,EVENIFENTERASYSHASBEENADVISEDOFTHEPOSSIBILITYOFSUCHDAMAGES.
THISFOREGOINGLIMITATIONSHALLAPPLYREGARDLESSOFTHECAUSEOFACTIONUNDERWHICH
DAMAGESARESOUGHT.
THECUMULATIVELIABILITYOFENTERASYSTOYOUFORALLCLAIMSRELATINGTOTHEPROGRAM,
INCONTRACT,TORTOROTHERWISE,SHALLNOTEXCEEDTHETOTALAMOUNTOFFEESPAIDTO
ENTERASYSBYYOUFORTHERIGHTSGRANTEDHEREIN.
viii

8. AUDITRIGHTS. YouherebyacknowledgethattheintellectualpropertyrightsassociatedwiththeProgramare
ofcriticalvaluetoEnterasys,and,accordingly,Youherebyagreetomaintaincompletebooks,recordsandaccounts
showing(i)licensefeesdueandpaid,and(ii)theuse,copyinganddeploymentoftheProgram.Youalsograntto
Enterasysanditsauthorizedrepresentatives,uponreasonablenotice,therighttoauditandexamineduringYour
normalbusinesshours,Yourbooks,records,accountsandhardwaredevicesuponwhichtheProgrammaybedeployed
toverifycompliancewiththisAgreement,includingtheverificationofthelicensefeesdueandpaidEnterasysandthe
use,copyinganddeploymentoftheProgram.Enterasysrightofexaminationshallbeexercisedreasonably,ingood
faithandinamannercalculatedtonotunreasonablyinterferewithYourbusiness.Intheeventsuchauditdiscovers
noncompliancewiththisAgreement,includingcopiesoftheProgrammade,usedordeployedinbreachofthis
Agreement,YoushallpromptlypaytoEnterasystheappropriatelicensefees.Enterasysreservestheright,tobe
exercisedinitssolediscretionandwithoutpriornotice,toterminatethislicense,effectiveimmediately,forfailureto
complywiththisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramandshall
returntoEnterasystheProgramandallcopiesoftheProgram.
9. OWNERSHIP. Thisisalicenseagreementandnotanagreementforsale.Youacknowledgeandagreethatthe
Programconstitutestradesecretsand/orcopyrightedmaterialofEnterasysand/oritssuppliers.Youagreeto
implementreasonablesecuritymeasurestoprotectsuchtradesecretsandcopyrightedmaterial.Allright,titleand
interestinandtotheProgramshallremainwithEnterasysand/oritssuppliers.Allrightsnotspecificallygrantedto
YoushallbereservedtoEnterasys.
10. ENFORCEMENT. YouacknowledgeandagreethatanybreachofSections2,4,or9ofthisAgreementbyYoumay
causeEnterasysirreparabledamageforwhichrecoveryofmoneydamageswouldbeinadequate,andthatEnterasys
maybeentitledtoseektimelyinjunctiverelieftoprotectEnterasysrightsunderthisAgreementinadditiontoanyand
allremediesavailableatlaw.
11. ASSIGNMENT. Youmaynotassign,transferorsublicensethisAgreementoranyofYourrightsorobligations
underthisAgreement,exceptthatYoumayassignthisAgreementtoanypersonorentitywhichacquiressubstantially
allofYourstockassets.EnterasysmayassignthisAgreementinitssolediscretion.ThisAgreementshallbebinding
uponandinuretothebenefitoftheparties,theirlegalrepresentatives,permittedtransferees,successorsandassignsas
permittedbythisAgreement.Anyattemptedassignment,transferorsublicenseinviolationofthetermsofthis
AgreementshallbevoidandabreachofthisAgreement.
12. WAIVER. AwaiverbyEnterasysofabreachofanyofthetermsandconditionsofthisAgreementmustbein
writingandwillnotbeconstruedasawaiverofanysubsequentbreachofsuchtermorcondition.Enterasysfailureto
enforceatermuponYourbreachofsuchtermshallnotbeconstruedasawaiverofYourbreachorpreventenforcement
onanyotheroccasion.
13. SEVERABILITY. IntheeventanyprovisionofthisAgreementisfoundtobeinvalid,illegalorunenforceable,the
validity,legalityandenforceabilityofanyoftheremainingprovisionsshallnotinanywaybeaffectedorimpaired
thereby,andthatprovisionshallbereformed,construedandenforcedtothemaximumextentpermissible.Anysuch
invalidity,illegality,orunenforceabilityinanyjurisdictionshallnotinvalidateorrenderillegalorunenforceablesuch
provisioninanyotherjurisdiction.
14. TERMINATION. EnterasysmayterminatethisAgreementimmediatelyuponYourbreachofanyoftheterms
andconditionsofthisAgreement.Uponanysuchtermination,YoushallimmediatelyceasealluseoftheProgramand
shallreturntoEnterasystheProgramandallcopiesoftheProgram.

ix

Contents
About This Guide
Who Should Use This Guide ...............................................................................................................xiii
How to Use This Guide ...................................................................................................................... xiv
Related Documents ........................................................................................................................... xiv
Getting Help ....................................................................................................................................... xvi

Chapter 1: Introduction
Overview of DFE-Platinum Series Capabilities ..................................................................................1-1
DFE-Platinum Module ........................................................................................................................1-2
Connectivity .......................................................................................................................................1-4
Management ......................................................................................................................................1-4
Switch Configuration Using WebView .........................................................................................1-4
Switch Configuration Using CLI Commands ...............................................................................1-4
Standards Compatibility .....................................................................................................................1-4
LANVIEW Diagnostic LEDs ...............................................................................................................1-4

Chapter 2: Network Requirements


10BASE-T Network ............................................................................................................................2-1
100BASE-TX Network .......................................................................................................................2-2

Chapter 3: Installation
Unpacking the DFE-Platinum Module ................................................................................................3-2
Backplane Connections and Installation Rules ..................................................................................3-2
FTM1 and FTM2 Connectivity .....................................................................................................3-2
Module Placement and Rules ......................................................................................................3-3
Installing Module into a Matrix E7 or Matrix N7 Chassis ....................................................................3-6
Preparation ..................................................................................................................................3-6
Installation ...................................................................................................................................3-7
Installing Module into Matrix N3 Chassis ...........................................................................................3-9
Connecting to the Network ...............................................................................................................3-11
Connecting UTP Cables to 7H4202-72 .....................................................................................3-11
Connecting to COM Port for Local Management .............................................................................3-15
What Is Needed .........................................................................................................................3-15
Connecting to an IBM PC or Compatible Device .......................................................................3-16
Connecting to a VT Series Terminal ..........................................................................................3-17
Connecting to a Modem ............................................................................................................3-18
Adapter Wiring and Signal Assignments ...................................................................................3-20
Completing the Installation ...............................................................................................................3-21
Completing the Installation of a New System ............................................................................3-21
Completing the Installation in an Existing System .....................................................................3-23

xi

Chapter 4: Troubleshooting
Using LANVIEW .................................................................................................................................4-1
Troubleshooting Checklist ..................................................................................................................4-5
Overview of DFE-Platinum Module Shutdown Procedure .................................................................4-7
Recommended Shutdown Procedure Using OFFLINE/RESET Switch .......................................4-8
Last Resort Shutdown Procedure Using OFFLINE/RESET Switch .............................................4-8

Appendix A: Specifications
DFE-Platinum Module Specifications ................................................................................................ A-1
COM Port Pinout Assignments ......................................................................................................... A-2
Regulatory Compliance ..................................................................................................................... A-3

Appendix B: Mode Switch Bank Settings


Index
Figures
1-1
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
3-9
3-10
3-11
3-12
4-1
4-2
B-1

7H4202-72 DFE-Platinum Module................................................................................................1-3


Examples, Module Placement in Matrix E7 Chassis ....................................................................3-4
Installing Module into a Matrix E7 or N7 Chassis (Matrix E7 shown) ...........................................3-8
Installing Module into Matrix N3 Chassis....................................................................................3-10
Connecting a Twisted Pair Segment to the 7H4202-72 .............................................................3-12
Crossover 4-Wire Cable RJ45 Pinouts, Connections Between Hub Devices ............................3-13
Straight-Through 4-Wire Cable RJ45 Pinouts, Connections
Between Switches and End-User Devices .................................................................................3-13
Crossover 8-Wire Cable RJ45 Pinouts, Connections Between Hub Devices ............................3-14
Straight-Through 8-Wire Cable RJ45 Pinouts, Connections
Between Switches and End-User Devices .................................................................................3-14
Connecting to an IBM PC or Compatible....................................................................................3-17
Connecting to a VT Series Terminal...........................................................................................3-18
Connecting to a Modem .............................................................................................................3-19
DFE Startup Screen Example (N7 Chassis)...............................................................................3-23
LANVIEW LEDs............................................................................................................................4-2
OFFLINE/RESET Switch..............................................................................................................4-7
Mode Switch Location ................................................................................................................. B-2

Tables
3-1
4-1
4-2
A-1
A-2
A-3
xii

Contents of DFE-Platinum Module Carton ...................................................................................3-2


LANVIEW LEDs............................................................................................................................4-3
Troubleshooting Checklist ............................................................................................................4-5
7H4202-72 Specifications............................................................................................................ A-1
COM Port Pin Assignments......................................................................................................... A-2
Compliance Standards ................................................................................................................ A-3

About This Guide


Thisguideprovidesanoverview,installationandtroubleshootinginstructions,and
specificationsfortheEnterasysMatrixDFE(DistributedForwardingEngine)module,
DFEPlatinum7H420272.
ForinformationabouttheCLI(CommandLineInterface)setofcommandsusedto
configureandmanagetheDFEPlatinummodule,refertotheEnterasysMatrix
DFEPlatinumSeriesConfigurationGuide.
Note: In this guide, DFE-Platinum module, unless otherwise noted, refers to the
7H4202-72.

Important Notice
Depending on the firmware version used in the DFE-Platinum module, some features described in
this document may not be supported. Refer to the Release Notes shipped with the DFE-Platinum
module to determine which features are supported.

Who Should Use This Guide


Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de
instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.

Thisguideisintendedforanetworkadministratorresponsibleforinstallingandsetting
uptheDFEPlatinummodule.

DFE-Platinum Series Hardware Installation Guide

xiii

How to Use This Guide

How to Use This Guide


ThisprefaceprovidesanoverviewofthisguideandtheDFEPlatinumSeriesmanualset,
abriefsummaryofeachchapter,definestheconventionsusedinthisdocument,and
instructshowtoobtaintechnicalsupport.Tolocateinformationaboutvarioussubjectsin
thisguide,refertothefollowingtable:
For...

Refer to...

An overview of the DFE-Platinum module

Chapter 1, Introduction

Network requirements that must be met before


installing the DFE-Platinum module

Chapter 2, Network Requirements

Instructions to install the DFE-Platinum module


hardware

Chapter 3, Installation

Troubleshooting installation problems and


diagnosing network/operational problems using the
LANVIEW LEDs

Chapter 4, Troubleshooting

Specifications, environmental requirements, and


physical properties of the DFE-Platinum module

Appendix A, Specifications

Instructions to set the mode switches when


necessary

Appendix B, Mode Switch Bank Settings

Related Documents
ThemanualslistedbelowcanbeobtainedfromtheWorldWideWebinAdobeAcrobat
PortableDocumentFormat(PDF)atthefollowingsite:
http://www.enterasys.com/support/manuals

EnterasysMatrixDFEPlatinumSeriesConfigurationGuideprovidesinformationon
howtousetheCommandLineInterfacetosetupandmanagetheDFEPlatinum
modules.

CablingGuideprovidesinformationondBlossandcablespecifications.
UnliketheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide,theCabling
Guideisnotlistedalphabeticallyonthewebsite.Instead,itislistedunderthe
OverviewGuideslink.

xiv

About This Guide

Related Documents

Conventions Used in This Guide


Thefollowingconventionsareusedinthisguide:
blue type

Indicates a hypertext link. When reading this document online, click the text in blue to
go to the referenced figure, table, or section.
Note: Calls the readers attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaucin: Contiene informacin esencial para prevenir daar el equipo.
Achtung: Verweit auf wichtige Informationen zum Schutz gegen Beschdigungen.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una accin que pudiera resultar en lesin corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfllen fhren knnen!
Electrical Hazard: Warns against an action that could result in personal injury or
death.
Riesgo Electrico: Advierte contra una accin que pudiera resultar en lesin corporal
o la muerte debido a un riesgo elctrico.
Elektrischer Gefahrenhinweis: Warnung vor smtlichen Handlungen, die zu
Verletzung von Personen oder Todesfllen hervorgerufen durch elektrische
Spannung fhren knnen!

Lowercasex:Indicatesthegeneraluseofanalphanumericcharacter(e.g.,6x1xx,thexs
indicateacombinationofnumbersorletters).

DFE-Platinum Series Hardware Installation Guide

xv

Getting Help

Getting Help
Foradditionalsupportrelatedtothemoduleorthisdocument,contact
Enterasys Networksusingoneofthefollowingmethods:
World Wide Web

www.enterasys.com/services/support/

Phone

1-800-872-8440 (toll-free in U.S. and Canada)


or 1-978-684-1000
For the Enterasys Networks Support toll-free number in your country:
www.enterasys.com/services/support/contact/

Internet mail

support@enterasys.com
To expedite your message, type [SWITCHING] in the subject line.

To send comments concerning this document to the Technical Publications Department:


techpubs@enterasys.com
Please include the document Part Number in your email message.

BeforecontactingEnterasys Networksfortechnicalsupport,havethefollowing
informationready:

xvi

YourEnterasys Networksservicecontractnumber

Adescriptionofthefailure

Adescriptionofanyaction(s)alreadytakentoresolvetheproblem(forexample,
changingmodeswitches,rebootingtheunit)

TheserialandrevisionnumbersofallinvolvedEnterasys Networksproductsinthe
network

Adescriptionofyournetworkenvironment(forexample,layoutandcabletype)

Networkloadandframesizeatthetimeoftrouble(ifknown)

Thedevicehistory(forexample,haveyoureturnedthedevicebefore,isthisa
recurringproblem)

AnypreviousReturnMaterialAuthorization(RMA)numbers

About This Guide

1
Introduction
ThischapterprovidesanoverviewoftheDFEPlatinumseriesmodulescapabilities,and
introducesthe7H420272DFEPlatinummodule.

Overview of DFE-Platinum Series Capabilities


ThePlatinumDistributedForwardingEngine(DFE)isEnterasys Networksnext
generationofenterprisemodulesfortheMatrixNSeriesandMatrixE7switches.These
DFEmodulesdeliverhighperformanceandflexibilitytoensurecomprehensive
switching,routing,QualityofService,security,andtrafficcontainment.Keyfeatures
include:

Superiorperformanceandcapacitytosupportmorehighbandwidthandlatency
sensitiveapplications

10/100/1000BaseTXand10GigabitEthernetconnectivity

IntegratedServicesDesignthatreducesthenumber/typeofmodulesrequired,
simplifiesnetworkdesign,andlowersentrycost

PortandUserBasedPolicyandMultilayerPacketClassificationthatprovides
granularcontrolandsecurityforbusinesscriticalapplications

Highavailabilityserviceswithstatefulfailoverforservicesandmanagement

Selflearningconfigurationmoduleswithincreasedreliabilityandfaulttolerancethat
reducesconfigurationtimeandmaximizesuptime

Networkwideconfiguration,change,andinventorymanagementthatiseasierto
install,troubleshoot,andmaintain

Reducedsupportandmaintenancecosts,anddecreasedconfigurationtime

SupportforavarietyofconvergedapplicationsincludingVoIPwithPowerover
Ethernet

DFE-Platinum Series Hardware Installation Guide

1-1

DFE-Platinum Module

DFE-Platinum Module
Thissectionprovidesanoverviewofthe7H420272DFEPlatinummoduleshownin
Figure 11.Forinformationaboutthe7H420272featuresandhowtoconfigurethem,
refertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuide.

7H4202-72
The7H420272DFEPlatinummodulehas72,10BASET/100BASETXcompliantports,
viafixedfrontpanelRJ45connectors.The7H420272canbeinstalledinaMatrix E7,
Matrix N7,orMatrix N3chassis.
Eachofthefixedfrontpanelportscanoperateineitherhalfduplexorfullduplexmode
ofoperation.Theduplexmodecanbedeterminedbyeitherautonegotiationormanual
configuration.
TheDFEPlatinummoduleportscanbeconfiguredtocontroltrafficbylimitingtherateof
trafficacceptedintothemoduleandprioritizingtraffictoexpeditetheflowofhigher
prioritytrafficthroughthemoduleinasecuremanor.
TheDFEPlatinummodulereceivespowerandbackplaneconnectivitywhenitisinserted
intotheMatrix E7,Matrix N7,orMatrix N3chassis.

1-2

Introduction

DFE-Platinum Module

Figure 1-1

7H4202-72 DFE-Platinum Module


FAST ENET
7H4202-72
OFFLINE / RESET

COM

CPU
MGMT
1X

GROUP 1

GROUP 2

6X
7X

12X

13X

18X
19X

24X

1 2 3

DFE

1
2
3
4
5

OFFLINE/RESET switch
RJ45 COM (Console Port)
CPU LED
MGMT LED
Group 3, 20 Ports, 10/100 Mbps, via RJ45s

GROUP
SELECT

6
7
8
9

GROUP LEDs
GROUP SELECT button
GROUP status LEDs
Groups 1&2, 40 Ports, 10/100 Mbps, via RJ45s

DFE-Platinum Series Hardware Installation Guide

1-3

Connectivity

Connectivity
The7H420272cansupportupto72,10BASET/100BASETXswitchedportsconnected
through72fixedfrontpanelconnectors.

Management
Managementofthemodulecanbeeitherinbandoroutofband.Inbandremote
managementispossibleusingTelnet,Enterasys NetworksNetSightmanagement
application,orWebViewapplication.Outofbandmanagementisprovidedthrough
theRJ45COM(Communication)portonthefrontpanelusingaVT100terminalora
VT100terminalemulator.

Switch Configuration Using WebView


Enterasys NetworksHTTPbasedWebmanagementapplication(WebView)isan
intuitivewebtoolforsimplemanagementtasks.

Switch Configuration Using CLI Commands


TheCLIcommandsenableyoutoperformmorecompleteswitchconfiguration
managementtasks.
ForCLIcommandsetinformationandhowtoconfigurethemodule,refertotheEnterasys
MatrixDFEPlatinumSeriesConfigurationGuide.

Standards Compatibility
TheDFEPlatinummodulesarefullycompliantwiththeIEEE802.32002,802.3ae2002,
802.1D1998,and802.1Q1998standards.TheDFEPlatinummoduleprovidesIEEE
802.1D1998SpanningTreeAlgorithm(STA)supporttoenhancetheoverallreliabilityof
thenetworkandprotectagainstloopconditions.

LANVIEW Diagnostic LEDs


LANVIEWdiagnosticLEDsserveasanimportanttroubleshootingaidbyprovidingan
easywaytoobservethestatusofindividualportsandoverallnetworkoperations.

1-4

Introduction

2
Network Requirements
Beforeinstallingthemodule,reviewtherequirementsandspecificationsreferredtoin
thischapterconcerningthefollowing:
For information about...

Refer to page...

10BASE-T Network

2-1

100BASE-TX Network

2-2

Thenetworkinstallationmustmeettherequirementstoensuresatisfactoryperformance
ofthisequipment.Failuretodosowillproducepoornetworkperformance.
Note: The Enterasys Matrix DFE-Platinum Series Configuration Guide and the Cabling
Guide referred to in the following sections can be found on the Enterasys Networks World
Wide Web site: http://www.enterasys.com/
Refer to Related Documents on page xiv.

10BASE-T Network
Whenconnectinga10BASETsegmenttoanyofthemodulefixedfrontpanelportsofthe
7H420272, ensurethatthenetworkmeetstheEthernetnetworkrequirementsofthe
IEEE 802.32002standardfor10BASET.RefertotheCablingGuidefordetails.
Note: If a port is to operate at 100 Mbps, Category 5 cabling must be used. Category 3
cabling does not meet 100 Mbps specifications. For 10 Mbps operation only, Category 3 or
Category 5 cabling can be used. Refer to 100BASE-TX Network on page 2-2 for
information about 100BASE-TX networks and cabling.

DFE-Platinum Series Hardware Installation Guide

2-1

100BASE-TX Network

100BASE-TX Network
Fixedfrontpanelportsofthe7H420272 provideaconnectionthatsupportsCategory5
UTPcabling.ThedeviceattheotherendofthetwistedpairsegmentmustmeetIEEE
802.32002100BASETXFastEthernetnetworkrequirementsforthedevicestooperateat
100 Mbps.RefertotheCablingGuidefordetails.
Note: The fixed ports of the module support Category 5 UTP cabling with an impedance
between 85 and 111 ohms for 100 Mbps operation.
The module is capable of operating at either 10 or 100 Mbps. The module automatically
senses the speed of the other device and adjusts its speed accordingly.

2-2

Network Requirements

3
Installation
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Elctrico: Solamente personal calificado debe realizar procedimientos de
instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und
qualifiziertes Personal vorgenommen werden.

Important Notice
Read the Release Notes shipped with the DFE-Platinum module to check for any exceptions to the
supported features and operation documented in this guide.

Thischapterprovidestheinstructionstoinstallthe7H420272DFEPlatinummodule.
Followtheorderofthesectionslistedbelowtocorrectlyinstallthemodule.
For information about...

Refer to page...

Unpacking the DFE-Platinum Module

3-2

Backplane Connections and Installation Rules

3-2

Installing Module into a Matrix E7 or Matrix N7 Chassis

3-6

Installing Module into Matrix N3 Chassis

3-9

Connecting to the Network

3-11

Connecting to COM Port for Local Management

3-15

Completing the Installation

3-21

DFE-Platinum Series Hardware Installation Guide

3-1

Unpacking the DFE-Platinum Module

Unpacking the DFE-Platinum Module


UnpacktheDFEPlatinummoduleasfollows:
1.

OpentheboxandremovethepackingmaterialprotectingtheDFEPlatinummodule.

2.

VerifythecontentsofthecartonaslistedinTable 31.

Table 3-1

Contents of DFE-Platinum Module Carton

Item

Quantity

DFE-Platinum module (7H4202-72)

Installation Guide

Customer Release Notes

3.

RemovethetapesealonthenonconductivebagtoremovetheDFEPlatinum
module.

Backplane Connections and Installation Rules


Thefollowingsectionsdescribe

theFrameTransferMatrixFTM1andFTM2backplaneconnections,

thehardwareconfigurationruleswheninstallingfirst(6x1xx),second(6x2xx),and
third(6x3xx)generationmodules,andDFEPlatinummodules(7x4xxx)intothesame
MatrixE7chassis.

FTM1 and FTM2 Connectivity


TheMatrix E7(6C107)chassishasbackplanesreferredtoasFTM1andFTM2.The7xxxxx
DFEPlatinummodulesuseFTM2forhighspeedcommunicationtoeachotherand
operateasoneswitchingunitwithasingleIPaddress.The7H420272connectstoFTM2
only.ThetrafficthroughthesemodulesdoesnotconnecttoFTM1exceptthroughanFTM
bridgingmodulesuchastheDFEPlatinummodule7H438225,7H438249,or7H438349.
Note: For more information about the 7H4382-25, 7H4382-49, or 7H4383-49, refer to the
Enterasys Matrix DFE-Platinum 7H4382-25 Installation Guide (9033912-00 or later) or to
the Enterasys Matrix DFE-Platinum Series (7H4382-49, 7H4383-49, 7G4270-12,
7G4202-30, 7H4203-72) Installation Guide (9033835-05 or later). For instructions to view
these manuals on the web, refer to Related Documents on page xiv.

3-2

Installation

Backplane Connections and Installation Rules

TheFTMbridgingmoduleshaveconnectionstobothFTM1andFTM2backplanes,which
enablesthemtoswitchframesbetweenthetwobackplanesandallmodulesinthe6C107
chassis.However,theolderfirst(6x1xx),second(6x2xx),andthird(6x3xx)generation
modulesarestillmanagedusingtheirownLocalManagementandarenotsubjectto
managementbytheDFEPlatinummodulemanagemententity.
TheMatrixN3(7C103)andMatrixN7(7C107)chassishaveonlyFTM2connectionsto
supportDFEPlatinummodulesorDFEGoldmodules(notdiscussedinthisbook).
Note: The Matrix N3 (7C103) and Matrix N7 (7C107) chassis will support either
DFE-Platinum modules or DFE-Gold modules, but not in the same chassis.

Module Placement and Rules


Note: The following module placement rules apply to the DFE-Platinum series modules
only.

DFEPlatinumseriesmodulescanbeinstalledinaMatrix E7,Matrix N3,orMatrix N7


chassis.Wheninstallingthemodulesintooneofthesechassis,makesuretoconsiderthe
followingplacementrulesfortheappropriatechassisandmodulemix.

Matrix N3 Chassis, Module Placement


TheMatrix N3chassisslots1through3willsupportDFEPlatinummodules.
Rule:TherearenoparticularrulesforinstallingonlyDFEPlatinummodulesintoa
Matrix N3chassis.

Matrix N7 Chassis, Module Placement


TheMatrix N7chassisslots1through7willsupportonlyDFEPlatinummodules.
Rule:TherearenoparticularrulesforinstallingonlyDFEPlatinummodulesintoa
Matrix N7chassis.

Matrix E7 Chassis, Module Placement


DependingonthemodulesbeinginstalledintheMatrixE7chassisandtohelpensure
properoperation,considerthefollowingexamplesandrulesformoduleplacementinthe
chassis.Figure 31showssixexamplesofchassismoduleplacement.Theseexamplesare
describedinthefollowingpagesalongwiththeapplicablemoduleplacementrule.

DFE-Platinum Series Hardware Installation Guide

3-3

Backplane Connections and Installation Rules

Figure 3-1

Examples, Module Placement in Matrix E7 Chassis

7XXXXX

6X3XX

1 2 3 4 5 6 7

1 2 3 4 5 6 7

6X1XX
6X2XX

1 2 3 4 5 6 7

D
6X1XX
6X2XX
+
6X3XX 6X3XX

1 2 3 4 5 6 7

7H4202-72 7XXXXX
6X2XX

6X1XX
6X2XX
6X3XX
7XXXXX 6X3XX

1 2 3 4 5 6 7

6X1XX
6X3XX
6X3XX

1 2 3 4 5 6 7

Example 1 (Figure 3-1, A)


ShowsthechassisfullypopulatedwithDFEPlatinummodules(7x4xxx).Thesemodules
communicatewitheachotherviatheFTM2chassisbackplaneandactasasingle
switchingentitywithoneIPaddress.TheDFEPlatinummodulesareconfiguredusinga
CommandLineInterfacesetofcommands.
Rule:DFEPlatinummodulescanbeinstalledinanyavailablechassisslotintheMatrixE7
chassis.

Example 2 (Figure 3-1, B)


Showsthechassisfullypopulatedwiththirdgenerationmodules(6x3xx).Thesemodules
canalsobeinstalledinanyavailablechassisslotintheMatrixE7chassis,butoperateas
individualmoduleswithseparateIPaddresses.EachmoduleisconfiguredusingLocal
Management.
Rule:The6x3xxmodulescanbeinstalledinanyavailablechassisslotintheMatrixE7
chassis.

Example 3 (Figure 3-1, C)


Showschassisslots1through5populatedwithfirstandsecondgenerationmodules
(6x1xxand6x2xx).Ifa6x1xxor6x2xxseriesmoduleisinstalledinslot6or7,itwill
operateinstandalonemode(nobackplaneconnectivity).Likethe6x3xxmodules,the
6x1xxand6x2xxmodulesoperateasindividualmoduleswithseparateIPaddresses,and
eachoneisconfiguredusingLocalManagement.
Rule:The6x1xxand6x2xxmodulescancommunicatewitheachotherwhentheyare
installedinchassisslots1through5intheMatrixE7chassis.Ifinstalledinslot6or7,they
operateinstandalonemode.

3-4

Installation

Backplane Connections and Installation Rules

Example 4 (Figure 3-1, D)


Showschassisslots1through5populatedwithamixof6x1xx,6x2xx,and6x3xxmodules
andonlythirdgenerationmodulesinslots6and7.
Inthismodulearrangement,the6x3xxmoduleprovidesaproxybridge,whichenables
the6x1xxand6x2xxmodulestocommunicatewith6x3xxmodulesinslot6or7.Ifmore
thanone6x3xxmoduleisinstalledinslots1to5,themoduleinthelowestnumberedslot
performstheproxyfunctionforslots6and7.Therefore,ifa6x3xxmoduleisalready
performingtheproxyfunction,andanother6x3xxmoduleisinsertedintoalower
numberedslot,connectivitywillbetemporarilyinterrupted,asthenewboardtakesover
theproxyfunction.Whena6x3xxmoduleinalowernumberedslotisremoved,andthere
isa6x3xxmoduleinahighernumberedslot,communicationisnotinterrupted.
ForLocalManagement,pluggingtheLocalManagementconnectionintothe6x3xx
moduleswillallowmanagementconnectionstoall6x1xx,6x2xx,and6x3xxmodules.If
theLocalManagementconnectionistoa6x1xxor6x2xxboard,onlythemodulesinthe
firstfiveslotswillberecognizedbythemanagementclient.
Rule:Theremustbeatleastone6x3xxmoduleinslots1through5toenable
communicationsbetweenthe6x1xx,6x2xx,and6x3xxmodules.

Example 5 (Figure 3-1, E)


Showschassisslots1and5populatedwith6x1xx,6x2xxmodules,respectively;slots2
through4withDFEPlatinummoduleswithoutabridgingmodule;andslots6and7with
6x3xxmodules.
Inthismodulearrangement,the6x2xxmoduleinslot1andthe6x2xxmoduleinslot5can
onlycommunicatewitheachother,becausethereisno6x3xxmoduleinoneofthefirst
fiveslotstoserveastheproxybridgetocommunicatewiththe6x3xxmodulesinslots6
and7.The7x4xxxDFEPlatinummodulesinslots2,3,and4willoperateunderoneIP
address.Sincethereisnobridgingmodule(7H438225,7H438249,or7H438349),the
DFEPlatinummoduleswillnotcommunicatewithanyothermodulesinthechassis.
Rule:Inthisexample,theremustbeatleastone6x3xxseriesmodule,andaDFE
Platinumbridgingmodule(7H438225,7H438249,or7H438349)inslots1through5to
enablecommunicationsbetweenallgenerationsofmodulesinthechassis.

Example 6 (Figure 3-1, F)


ThemodulearrangementinthisexampleissimilartotheoneshowninFigure 31,Eand
describedinExample5.Theonlydifferenceisthata7H438249bridgingmoduleis
installedinslot2,enablingallmodulestocommunicatewitheachother.
Rule: Inthisexample,the7H438249servesasboththeFTM1toFTM2bridgeandthe
fivetosevenslotproxybridge.The6x3xxdoesnotserveasaproxybridgeinthis
configurationbecausethe7H438249isinaslotwithalowernumber.Youcanusethe
7H438225,7H438249,or7H438349asthebridgingmoduledependingontheneed.

DFE-Platinum Series Hardware Installation Guide

3-5

Installing Module into a Matrix E7 or Matrix N7 Chassis

Installing Module into a Matrix E7 or Matrix N7 Chassis


Caution: Failure to observe static safety precautions could cause damage to the
DFE-Platinum module. Follow static safety handling rules and wear the antistatic wrist
strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the
board or components can cause damage.
Precaucin: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad esttica, es posible que el mdulo se dae. Siga los consejos de seguridad
para la manipulacin del producto y no olvide utilizar la pulsera antiesttica.
No corte la bolsa antiesttica para sacar el mdulo. Tenga en cuenta que si algn objeto
cortante entra en contacto con la placa o con los componentes, stos podran daarse.

ToinstallaDFEPlatinummoduleintoaMatrix E7orMatrix N7 chassis,proceeddirectly


toPreparationonpage 36tostarttheinstallationprocess.

Preparation

3-6

Installation

1.

Removetheblankpanelcoveringthechassisslotinwhichthemodulewillbe
installed.Allotherslotsmustremaincoveredtoensureproperairflowforcooling.
(Savetheblankplateintheeventyouneedtoremovethemodule.)

2.

Removethemodulefromtheshippingbox.(Savetheboxandpackingmaterialsin
theeventthemoduleneedstobereshipped.)

3.

Locatetheantistaticwriststrapshippedwiththechassis.Attachtheantistaticwrist
straptoyourwristandplugthecablefromtheantistaticwriststrapintotheESD
groundingreceptacleattheupperrightcornerofthechassis.

4.

Removethemodulefromtheplasticbag.(Savethebagintheeventthemodulemust
bereshipped.)ObserveallprecautionstopreventdamagefromElectrostatic
Discharge(ESD).

5.

Examinethemodulefordamage.Ifanydamageexists,DONOTinstallthemodule.
ImmediatelycontactEnterasysNetworks.RefertoLANVIEWdiagnosticLEDsserve
asanimportanttroubleshootingaidbyprovidinganeasywaytoobservethestatusof
individualportsandoverallnetworkoperations.onpage 14.

Installing Module into a Matrix E7 or Matrix N7 Chassis

Installation
Toinstallthemodule,refertoFigure 32andproceedasfollows:
Caution: To prevent damaging the backplane connectors in the following step, take care
that the module slides in straight and properly engages the backplane connectors.
Ensure that the top lever lines up with the desired slot number located on the front panel of
the chassis. Refer to Figure 3-2.
Precaucin: Para evitar que se daen los conectores del panel posterior en el siguiente
paso, intente deslizar el mdulo en forma recta y verifique que se enganche
correctamente en los conectores de panel posterior.
Asegrese de que la palanca superior est alineada con respecto al nmero de ranura
correspondiente ubicado en el panel frontal del chasis. Consulte en Figure 3-2.

1.

Locatethechassiscardguidesthatlineupwiththeslotnumberinwhichthemodule
willbeinstalled.(Inthisexample,slot1isbeingused.)Makesurethemodulelocking
leversareintheopenposition(topandbottom).

DFE-Platinum Series Hardware Installation Guide

3-7

Installing Module into a Matrix E7 or Matrix N7 Chassis

Figure 3-2

Installing Module into a Matrix E7 or N7 Chassis (Matrix E7 shown)

SERIES

E7
7

FAST ENET
7H4202-72
COM

OFFLINE / RESET
CPU
MGMT
1X

GROUP 1

GROUP 2

GROUP 3

6X
7X

12X
13X

18X
19X

24X

GROUP

DFE

1 2 3

GROUP
SELECT

ACON
1

POWER

LINE
100-125V~12A
200-240V~6A
50/60Hz

FAN

ACON
1

POWER

LINE
100-125V~12A
200-240V~6A
50/60Hz

FAN

LINE
100-125V~12A
200-240V~6A
50/60Hz

PS1

1
2
3
4

3-8

Installation

Card guides
Slot number 1
Module card
Metal back panel

LINE
100-125V~12A
200-240V~6A
50/60Hz

PS2

5 Upper/lower locking levers (in proper open position)


6 Upper/lower locking levers (in closed position)
7 Backplane connectors
- Top two connectors (power and FTM2)
- Bottom two connectors (power and FTM1) (no bottom connectors in
Matrix N7 chassis)

Installing Module into Matrix N3 Chassis

2.

Alignthemodulecardbetweentheupperandlowercardguidesofthedesiredslot
andslideitintothechassis,takingcarethatthemoduleslidesinstraight.SeeCaution
below.
Caution: Due to the amount of force needed to properly seat the module connectors into
the backplane connectors, it is best to apply force to the end of the levers to insert (or
eject) the module. Otherwise, damage could result to the module and chassis.
Precaucin: Para colocar los conectores del mdulo en los conectores del panel
posterior correctamente es necesario hacer bastante fuerza, por ello, para insertar o
quitar el mdulo, se recomienda concentrar la fuerza en el extremo de las palancas. Si no
lo hace, podra daar el mdulo y el chasis.

3.

Slidethemoduleintotheslotuntilyoucanengagethetopandbottomlockinglevers
withthechassisasshowninFigure 32.
Caution: In step 4, do not force the locking levers to the point that they touch the face of
the front panel. Forcing the locking levers to this point could damage the module and
chassis.
Precaucin: En el paso 4, tenga cuidado de no llevar las palancas de cierre a un punto
en donde estn en contacto con el panel frontal. Si lo hace, podra daar el mdulo y/o el
chasis.

4.

RefertotheCautionnoteabove,thenrotatethetwoleversintotheclosedposition.

5.

Ifthechassisinwhichthemoduleisinstalledwaspowereddownfortheinstallation,
turnthepowersupplieson.ChecktoseethatthemoduleCPULEDsettlesatsolid
greenafterafewminutes.IftheLEDdoesnotturnsolidgreen,refertoChapter 4for
troubleshootingdetails.

Installing Module into Matrix N3 Chassis


Caution: Failure to observe static safety precautions could cause damage to the
DFE-Platinum module. Follow static safety handling rules and wear the antistatic wrist
strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the
board or components can cause damage.
Precaucin: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad esttica, es posible que el mdulo se dae. Siga los consejos de seguridad
para la manipulacin del producto y no olvide utilizar la pulsera antiesttica.
No corte la bolsa antiesttica para sacar el mdulo. Tenga en cuenta que si algn objeto
cortante entra en contacto con la placa o con los componentes, stos podran daarse.

DFE-Platinum Series Hardware Installation Guide

3-9

Installing Module into Matrix N3 Chassis

ToinstallaDFEPlatinummoduleintotheMatrix N3 chassis, refertoFigure 33anduse


theinstallationproceduredescribedinInstallingModuleintoaMatrix E7orMatrix N7
Chassisonpage 36.A DFEPlatinummodule canbeinstalledinanyavailablechassis
slot(1 through3).
Caution: When setting the locking levers to the closed position, do not try to force the
locking levers to the point that they touch the face of the front panel. Forcing the locking
levers to this point could damage the module and chassis.
Precaucin: Al mover las palancas a la posicin de cerrado, tenga cuidado de no
llevarlas a un punto en donde estn en contacto con el panel frontal. Si lo hace, podra
daar el mdulo o el chasis.

Figure 3-3

Installing Module into Matrix N3 Chassis

1 2 3
GROUP

DFE

24X

19X

18X

13X

12X

REDUNDANCY

7X

1X

PWR

6X

COM

GROUP 3

CPU

MGMT

GROUP 2

OFFLINE / RESET

7H4202-72

GROUP 1

FAST ENET

7C203-1

GROUP
SELECT

100-125V~12.0A
200-240V~6.0A
50/60 Hz

7C203-1
PWR

REDUNDANCY

100-125V~12.0A
200-240V~6.0A
50/60 Hz

1
2
3
4

3-10

Installation

Card guides
Slot 1 (Top slot is slot 3.)
Module card
Metal back panel

5 Module upper locking lever (shown in closed position)


6 Module lower locking lever (shown in closed position)
7 FTM2 backplane connectors

Connecting to the Network

Connecting to the Network


ConnectingUTPCablesto7H420272onpage 311providestheproceduresfor
connectingunshieldedtwistedpair(UTP)segmentsfromthenetworkorotherdevices.
Note: If the DFE-Platinum module is being installed in a network using Link Aggregation,
there are rules concerning the network cable and port configurations that must be followed
for Link Aggregation to operate properly. Before connecting the cables, refer to the
Enterasys Matrix DFE-Platinum Series Configuration Guide for the configuration
information. For details on how to obtain manuals, refer to Related Documents on
page xiv.

Connecting UTP Cables to 7H4202-72


ThefixedRJ45frontpanelconnectionsofthe7H420272are10/100Mbpsports.Theports
haveinternalcrossovers,andalsosupportautomaticpolaritysensingwhenconfigured
forautomaticnegotiation.
Ifautomaticnegotiationisnotactivatedonaport,useastraightthroughcablewhen
connectingaworkstationtotheport.Whenconnectinganetworkingdevicetotheport,
suchasabridge,repeater,orrouter,useacrossovercable.
Ifaportissetforautonegotiation,automaticpolaritysensingisalsoactivated.
Automaticpolaritysensingeliminatestheneedforacrossovercable,regardlessifthe
connectionistoanothernetworkdeviceoraworkstation.
Note: All RJ45 front panel ports on the 7H4202-72 support Category 5 Unshielded
Twisted Pair (UTP) cabling with an impedance between 85 and 111 ohms. Category 3
cable may be used if the connection is going to be used only for 10 Mbps.

Inthisprocedure,the7H420272isusedastheexampletoconnectatwistedpairsegment
tothemodule.RefertoFigure 34andproceedasfollows:
1.

EnsurethatthedeviceconnectedtotheotherendofthesegmentispoweredON.

2.

ConnectthetwistedpairsegmenttothemodulebyinsertingtheRJ45connectoron
thetwistedpairsegmentintotheappropriateRJ45portconnector.

DFE-Platinum Series Hardware Installation Guide

3-11

Connecting to the Network

Figure 3-4

Connecting a Twisted Pair Segment to the 7H4202-72

FAST ENET
7H4202-72
COM

OFFLINE / RESET
CPU
MGMT

1X

GROUP 1

GROUP 2

GROUP 3

RX
TX

24X

GROUP

DFE

1 2 3

GROUP
SELECT

7X

1 RJ45 connector

3.

2 RJ45 port connector

3 GROUP SELECT button

VerifythatalinkexistsbycheckingthattheportRX(Receive)LEDisON(flashing
amber,blinkinggreen,orsolidgreen).IftheRXLEDisOFFandtheTX(Transmit)
LEDisnotblinkingamber,performthefollowingstepsuntilitison:
a.

Toviewthereceiveandtransmitactivityonagroupofsegments,pressthe
GROUPSELECTbutton(referbacktoFigure 34)tosteptothegroupofinterest
(Groups1through3).EachtimetheGROUPSELECTbuttonispressed,the
GROUPLEDlightsupinsequence,indicatingwhichGroupisselected.The
receiveandtransmitactivityforthatgroupofsegmentsisthenindicatedbythe
RXandTXLEDsforeachsegment.

b.

VerifythatthecablingbeingusedisCategory5UTPwithanimpedancebetween
85and111 ohms.Iftheportistooperateat100 Mbps,category 5cablingmustbe
used.

c.

Verifythatthedeviceattheotherendofthetwistedpairsegmentisonand
properlyconnectedtothesegment.

d. VerifythattheRJ45connectorsonthetwistedpairsegmenthavetheproper
pinoutsandcheckthecableforcontinuity.Typically,acrossovercableisused
betweenhubdevices.Astraightthroughcableisusedtoconnectbetween
switchesorhubdevicesandanenduser(computer).RefertoFigure 35and
Figure 36forfourwireRJ45connections.RefertoFigure 37andFigure 38for
eightwireRJ45connections.
3-12

Installation

Connecting to the Network

Figure 3-5
Devices

Crossover 4-Wire Cable RJ45 Pinouts, Connections Between Hub

RX+

RX+

RX

RX

TX+

TX+

TX

TX

1 RJ45 device port


2 Other device port

3 RJ45-to-RJ45 crossover cable


4 RX+/RX- and TX+/TX- connections. These
connections must share a common color pair.

Figure 3-6 Straight-Through 4-Wire Cable RJ45 Pinouts, Connections


Between Switches and End-User Devices

RX+

RX+

RX

RX

TX+

TX+

TX

TX

1 RJ45 device port


2 Other device port

3 RJ45-to-RJ45 straight-through cable


4 RX+/RX- and TX+/TX- connections. These connections
must share a common color pair.

DFE-Platinum Series Hardware Installation Guide

3-13

Connecting to the Network

Figure 3-7
Devices

Crossover 8-Wire Cable RJ45 Pinouts, Connections Between Hub

TX1+

TX2+

RX1-

RX2-

TX2+

TX1+

TX3+

TX4+

RX3-

RX4-

RX2-

RX1-

TX4+

TX3+

RX4-

RX3-

1 RJ45 device port


2 Other device port

3 RJ45-to-RJ45 crossover cable

Figure 3-8 Straight-Through 8-Wire Cable RJ45 Pinouts, Connections


Between Switches and End-User Devices

TX1+

TX2+

RX1-

RX2-

TX2+

TX1+

TX3+

TX4+

RX3-

RX4-

RX2-

RX1-

TX4+

TX3+

RX4-

RX3-

1 RJ45 device port


2 Other device port

3-14

Installation

3 RJ45-to-RJ45 straight-through cable

Connecting to COM Port for Local Management

e.

EnsurethatthetwistedpairconnectionmeetsthedBlossandcablespecifications
outlinedintheCablingGuide.RefertoRelatedDocumentsonpage xivfor
informationonobtainingthisdocument.

Ifalinkisnotestablished,contactEnterasysNetworks.RefertoLANVIEW
diagnosticLEDsserveasanimportanttroubleshootingaidbyprovidinganeasyway
toobservethestatusofindividualportsandoverallnetworkoperations.onpage 14
fordetails.
4.

Repeatsteps1through3above,untilallconnectionshavebeenmade.

Connecting to COM Port for Local Management


ThissectiondescribeshowtoinstallaUTPstraightthroughcablewithRJ45connectors
andoptionaladapterstoconnectaPC,aVTseriesterminal,oramodemtoa
DFEPlatinummodule.
Note: You can connect to any DFE-Platinum module in the chassis to access local
management for the DFE-Platinum system.

Thissectionalsoprovidesthepinoutassignmentsoftheadapters.

What Is Needed
Thefollowingisalistoftheusersuppliedpartsthatmaybeneededdependingonthe
connection:

RJ45toDB9femaleadapter

UTPstraightthroughcablewithRJ45connectors

RJ45toDB25femaleadapter

RJ45toDB25maleadapter

WithaUTPstraightthroughcablewithRJ45connectorsandRJ45toDB9adapter,you
canconnectproductsequippedwithanRJ45COMporttoanIBMorcompatiblePC
runningaVTseriesemulationsoftwarepackage.
WithaUTPstraightthroughcableandRJ45toDB25femaleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaVTseriesterminalorVTtypeterminals
runningemulationprogramsfortheVTseries.
WithaUTPstraightthroughcableandanRJ45toDB25maleadapter,youcanconnect
productsequippedwithanRJ45COMporttoaHayescompatiblemodemthatsupports
9600 baud.

DFE-Platinum Series Hardware Installation Guide

3-15

Connecting to COM Port for Local Management

Connecting to an IBM PC or Compatible Device


ToconnectanIBMPCorcompatibledevice,runningtheVTterminalemulation,toan
Enterasys NetworksmoduleCOMport(Figure 39),proceedasfollows:
1.

ConnecttheRJ45connectoratoneendofaUTPstraightthroughcabletothe
communicationsCOMportontheEnterasys Networksmodule.(TheCOMportis
alsoknownasaConsoleport.)

2.

PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintoan
RJ45toDB9femaleadapter.

3.

ConnecttheRJ45toDB9femaleadaptertothecommunicationsportontheIBMPC.

4.

TurnonthePCandconfigureyourVTemulationpackagewiththefollowing
parameters:
Parameter

Setting

Mode

7 Bit Control

Transmit

Transmit=9600

Bits Parity

8 Bits, No Parity

Stop Bit

1 Stop Bit

Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheappropriateEnterasysMatrixDFEPlatinumSeriesConfigurationGuidefor
furtherinformation.

3-16

Installation

Connecting to COM Port for Local Management

Figure 3-9

Connecting to an IBM PC or Compatible

FAST ENET
7H4202-72
COM

OFFLINE / RESET
CPU
MGMT
1X

GROUP 1

GROUP 2

GROUP 3

1
2

1 UTP straight-through cable with RJ45 connectors


2 COM (console) port

3 RJ45-to-DB9 female adapter


4 IBM PC or compatible device

Connecting to a VT Series Terminal


ToconnectaVTSeriesterminaltoanEnterasys NetworksDFEPlatinummoduleCOM
port(Figure 310),useaUTPstraightthroughcablewithRJ45connectorsandanRJ45to
DB25femaleadapter,andproceedasfollows:
1.

ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletotheCOM
portontheEnterasys Networksmodule.

2.

PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25femaleadapter.

3.

ConnecttheRJ45toDB25adaptertotheportlabeledCOMMontheVTterminal.

4.

TurnontheterminalandaccesstheSetupDirectory.Setthefollowingparameterson
yourterminal:
Parameter

Setting

Mode

7 Bit Control

Transmit

Transmit=9600

Bits Parity

8 Bits, No Parity

Stop Bit

1 Stop Bit

DFE-Platinum Series Hardware Installation Guide

3-17

Connecting to COM Port for Local Management

Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Figure 3-10

Connecting to a VT Series Terminal

FAST ENET
7H4202-72
OFFLINE / RESET

COM

CPU
MGMT
1X

GROUP 1

GROUP 2

GROUP 3

1 UTP straight-through cable with RJ45 connectors


2 RJ45 COM port

3 RJ45-to-DB25 female adapter


4 VT series terminal

Connecting to a Modem
ToconnectamodemtoanEnterasys NetworksDFEPlatinummoduleCOMport
(Figure 311),useaUTPstraightthroughcablewithRJ45connectorsandanRJ45toDB25
maleadapter,andproceedasfollows:

3-18

Installation

1.

ConnecttheRJ45connectoratoneendoftheUTPstraightthroughcabletotheCOM
portoftheDFE module.

2.

PlugtheRJ45connectorattheotherendoftheUTPstraightthroughcableintothe
RJ45toDB25maleadapter.

3.

ConnecttheRJ45toDB25adaptertothecommunicationsportonthemodem.

4.

Turnonthemodem.

Connecting to COM Port for Local Management

5.

WithaPCconnectedtoaremotemodem,youcanconfiguretheswitchremotely.To
accomplishthis,youmustconfigureyourPCVTemulationpackagewiththe
followingparameters.
Parameter

Setting

Mode

7 Bit Control

Transmit

Transmit=9600

Bits Parity

8 Bits, No Parity

Stop Bit

1 Stop Bit

Whentheseparametersareset,theLocalManagementpasswordscreenwilldisplay.
RefertotheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideforfurther
information.
Figure 3-11

Connecting to a Modem

FAST ENET
7H4202-72
OFFLINE / RESET

COM

CPU
MGMT
1X

GROUP 1

GROUP 2

GROUP 3

1 UTP straight-through cable with RJ45 connectors


2 RJ45 COM port
3 RJ45-to-DB25 male adapter

4 Local modem
5 Remote modem

DFE-Platinum Series Hardware Installation Guide

3-19

Connecting to COM Port for Local Management

Adapter Wiring and Signal Assignments


COM Port Adapter Wiring and Signal Diagram
RJ45

DB9

Pin

Conductor

Pin

Signal

Blue

Receive (RX)

Red

Transmit (TX)

Green

Ground (GRD)

Orange

Request to Send (RTS)

Yellow

Clear to Send (CTS)

Pins

Pins

9
6
DB9 Connector (Female)

RJ45 Connector (Female)

VT Series Port Adapter Wiring and Signal Diagram


RJ45

DB25

Pin

Conductor

Pin

Signal

Red

Transmit (TX)

Blue

Receive (RX)

Yellow

Clear to Send (CTS)

Green

Ground (GRD)

Orange

20

Data Terminal Ready

Pins

13

25

RJ45 Connector (Female)

3-20

Installation

Pins

DB25 Connector (Female)

14

Completing the Installation

Modem Port Adapter Wiring and Signal Diagram


RJ45

DB25

Pin

Conductor

Pin

Signal

Blue

Transmit (TX)

Orange

Data Carrier Detect (DCD)

Red

Receive

Green

Ground (GRD)

Yellow

20

Data Terminal Ready (DTR)

Gray

22

Ring Indicator

Pins

RJ45 Connector (Female)

Pins

14

DB25 Connector (Male)

13

25

Completing the Installation


CompletingtheDFEPlatinummoduleinstallationdependsonifthemoduleisbeing
installedin:

anewDFEPlatinummodulesystem(refertoCompletingtheInstallationon
page 321),or

anestablished,operatingDFEPlatinummodulesystem(refertoCompletingthe
InstallationinanExistingSystemonpage 323).

Completing the Installation of a New System


InanewsystemofDFEPlatinummodules,oneoftheinstalledDFEPlatinummodules
willbecomethemanagementmoduleonchassispowerup,andallDFEPlatinum
moduleswillautomaticallybesettothefactorydefaultvalues.Acompletelistofthe
factorydefaultvaluesareprovidedinChapter3oftheEnterasysMatrixDFEPlatinum
SeriesConfigurationGuide.
AfterinstallingallDFEPlatinummodulesintothehostchassisandmakingthe
connectionstothenetwork,proceedtothefollowingFirstTimeLogInUsingaConsole
PortConnectionproceduretoaccessthemodulemanagementstartupscreenfromyour
PC,terminal,ormodemconnection.

DFE-Platinum Series Hardware Installation Guide

3-21

Completing the Installation

First-Time Log-In Using a Console Port Connection


Note: This procedure applies only to initial log-in, and to logging in to a device not yet
configured with administratively-supplied user and password settings.
By default, the Matrix DFE-Platinum Series device is configured with three user login
accounts: ro for Read-Only access; rw for Read-Write access; and admin for super-user
access to all modifiable parameters. The default password is set to blank. For information
on changing these default passwords, refer to Chapter 3 in the Enterasys Matrix
DFE-Platinum Series Configuration Guide.

StarttheCommandLineInterface(CLI)fromthemoduleslocalconsoleportasfollows:
1.

ConnectaterminaltothelocalconsoleportasdescribedinConnectingtoCOMPort
forLocalManagementonpage 315.Thestartupscreen,Figure 312,displays.

2.

Attheloginprompt,enteroneofthefollowingdefaultusernames:

roforReadOnlyaccess,

rwforReadWriteaccess,or

adminforSuperUseraccess.(ThisaccesslevelallowsReadWriteaccesstoall
modifiableparameters,includinguseraccounts.)

3.

PressENTER.

4.

ThePasswordpromptdisplays.LeavethisstringblankandpressENTER.The
moduleinformationandMatrixpromptdisplaysasshowninFigure 312.

TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEPlatinum
management,refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfiguration
Guide.TheCLIcommandsenableyoutoinitiallysetupandperformmoreinvolved
managementconfigurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inLANVIEWdiagnosticLEDsserveasanimportanttroubleshootingaidbyproviding
aneasywaytoobservethestatusofindividualportsandoverallnetworkoperations.on
page 14.

3-22

Installation

Completing the Installation

Figure 3-12

DFE Startup Screen Example (N7 Chassis)

login: admin
Password:

M A T R I X N7
Command Line Interface
Enterasys Networks, Inc.
50 Minuteman Rd.
Andover, MA 01810-1008 U.S.A.
Phone: +1 978 684 1000
E-mail: support@enterasys.com
WWW:
http://www.enterasys.com
(c) Copyright Enterasys Networks, Inc. 2003
Chassis Serial Number:
xxxxxxxxxxxx
Chassis Firmware Revision: xx.xx.xx
Matrix N7(su)->

Completing the Installation in an Existing System


InanestablishedDFEPlatinummodulesystem,

aDFEPlatinummoduleisalreadyestablishedasthemanagementmodule,

thepasswordshavealreadybeensetforvarioususers,

thesystemIPaddressisset,and

othersystemparametershavebeenset.

WhenyouinstallanewDFEPlatinummoduleintoasystemwithanexistingconfigured
useraccount,thecurrentsystemsettingsinthataccountarealreadyrecognizedbythe
newDFEPlatinummoduleanditwilloperateaccordingly.
Ifyouneedtochangeanysettings,youcanconnectaterminaltothelocalconsoleportas
describedinConnectingtoCOMPortforLocalManagementonpage 315toaccess
systemmanagement,oruseaTelnetconnectiontoaccesstheDFEPlatinummodule
systemmanagementasdescribedinChapter3oftheEnterasysMatrixDFEPlatinumSeries
ConfigurationGuide.

DFE-Platinum Series Hardware Installation Guide

3-23

Completing the Installation

Logging in with an Administratively-Configured User Account


Ifthedevicesdefaultuseraccountsettingshavebeenchanged,proceedasfollows:
1.

Attheloginprompt,enteryouradministrativelyassignedusernameandpress
ENTER.

2.

AtthePasswordprompt,enteryourpasswordandpressENTER.

ThenoticeofauthorizationandtheMatrixpromptdisplaysasshownbackinFigure 312.
Note: Users with Read-Write (rw) and Read-Only access can use the set password
commandtochange their own passwords. Administrators with Super User (su) access
can use the set system login command to create and change user accounts, and the set
password command to change any local account password. For information on the set
password and set system login commands, refer to Chapter 3 in the Enterasys Matrix
DFE-Platinum Series Configuration Guide.

TheDFEPlatinummoduleisnowreadytobeconfigured.Forinformationaboutsetting
theIPaddressandconfiguringTelnetsettingsforremoteaccesstoDFEPlatinum
management,refertoChapter3intheEnterasysMatrixDFEPlatinumSeriesConfiguration
Guide.TheCLIcommandsenableyoutoinitiallysetupandperformmoreinvolved
managementconfigurations.
TheEnterasysMatrixDFEPlatinumSeriesConfigurationGuideisavailableonlineat:
http://www.enterasys.com/support/manuals
Ifyourequireassistance,contactEnterasysNetworksusingoneofthemethodsdescribed
inGettingHelponpage xvi.

3-24

Installation

4
Troubleshooting
Thischapterprovidesinformationconcerningthefollowing:
For information about...

Refer to page...

Using LANVIEW

4-1

Troubleshooting Checklist

4-5

Overview of DFE-Platinum Module Shutdown Procedure

4-7

Recommended Shutdown Procedure Using OFFLINE/RESET Switch

4-8

Last Resort Shutdown Procedure Using OFFLINE/RESET Switch

4-8

Unlessotherwisenoted,thefollowinginformationappliestoallDFEPlatinummodules.

Using LANVIEW
Themodulesuseabuiltinvisualdiagnosticandstatusmonitoringsystemcalled
LANVIEW.TheLANVIEWLEDs(Figure 41)allowquickobservationofthenetwork
statustoaidindiagnosingnetworkproblems.

About the Management (MGMT) LED


TheMGMTLED(showninFigure 41)indicateswhenthemoduleisservingasthe
ManagementModuletocontrolthemanagementfunctionsforallDFEPlatinummodules
inthechassis.TheManagementModulehandlesallIPrequeststothechassisIPaddress,
suchasPING,Telnet,SNMP,HTTP,etc.TheManagementModulealsohandlestheCLI
configurationsessionsviatheconsoleport.So,whenyouplugintoaDFEPlatinum
moduleCOMporttoconfigureaDFEPlatinummoduleinthechassis,itishandledbythe
ManagementModuleregardlessoftheDFEPlatinummoduleCOMportthatyouuse.

DFE-Platinum Series Hardware Installation Guide

4-1

Using LANVIEW

Viewing the Receive and Transmit Activity


Onthe7H420272,youcanviewthereceiveandtransmitactivityontheRXandTXLEDs.
However,onlyonegroupof24portsmaybeviewedatatime.
Toviewthereceiveandtransmitactivityonagroupofattachedsegments,pressthe
GROUPSELECTbutton(seeFigure 41)tosteptothegroupofinterest(Groups1
through 3).EachtimetheGROUPSELECTbuttonispressed,aGROUPLEDlightsupin
sequence,indicatingwhichgroupisselected.Thereceiveandtransmitactivityforthat
groupofsegmentsisthenindicatedbytheRXandTXLEDsforeachport.Figure 41
showsGroup3selectedandthelocationofGroup3,port1RXandTXLEDs.
Figure 4-1

LANVIEW LEDs
FAST ENET
7H4202-72
COM

OFFLINE / RESET
CPU

MGMT
1X

GROUP 1

GROUP 2

GROUP 3

GROUP 3

RX
TX

24X

GROUP

DFE

1 2 3

GROUP

GROUP
SELECT

7X

1 MGMT LED

1 2 3

GROUP
SELECT

2 Group LEDs

3 Group 3, port 1, RX/TX LEDs

Table 41describestheLEDindicationsandprovidesrecommendedactionsas
appropriate.
Note: The terms used in Table 4-1 indicate the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Alternating indicates an LED is flashing in a steady rate other than 50% on, 50% off.

4-2

Troubleshooting

Using LANVIEW

Table 4-1

LANVIEW LEDs

LED

Color

State

Recommended Action

MGMT

None

Off. This module is NOT the


Management Module.

None.

Green

Solid. This module is the


designated Management
Module.

None.

Amber

Flashing. This is a
temporary indication that the
module is saving data.

None.

None

Power off.

Ensure chassis has adequate power.

Amber

Blinking. Module in process


of booting.

None.

Solid. Testing.

If the LED remains amber for several


minutes, contact Enterasys Networks
for technical support.

Blinking. Image starts


running.

None.

Solid. Functional.

None.

Red

Solid. Processor in reset.

None.

Green
and
Amber

Blinking. Indicates that the


module is in the process of
shutting down.

None. This state is activated when the


OFFLINE/RESET switch is pressed for
less than 1 second to start the process
of an orderly shutdown.

CPU

Green

While in this state, do not remove any


DFE-Platinum module.
Amber
and off

Alternating (67% on, 33%


off). Indicates that a
shutdown process has
completed. This indication
will remain for 60 seconds
before automatically
restarting.

While in this state, you have 60 seconds


to safely remove the DFE-Platinum
module from the chassis.

DFE-Platinum Series Hardware Installation Guide

4-3

Using LANVIEW

Table 4-1
LED

Color

State

Recommended Action

RX
(Receive)

None

No link. No activity. Port


enabled or disabled.

None.

Green

Solid. Link present, port


enabled, no traffic is being
received by the interface.

None.

Amber

Flashing. Link present, port


enabled, traffic is being
received by the interface.

None.

Red

Blinking. Indicates
collisions. This indication is
only supported on 10/100
ports.

Contact Enterasys Networks for


technical support.

None

Port enabled, but no activity.

If it is known that the port should be


active and is not, contact Enterasys
Networks for technical support.

Green

Flashing. Indicates data


transmission activity. Rate of
flashing indicates the data
rate.

None.

Red

Flashing. Fault or Error


(collision).

None, unless there is a high rate of


activity. In this case, check for network
configuration problems or a defective
device.

TX
(Transmit)

4-4

LANVIEW LEDs (continued)

Troubleshooting

Troubleshooting Checklist

Troubleshooting Checklist
Ifthemoduleisnotworkingproperly,refertoTable 42forachecklistofproblems,
possiblecauses,andrecommendedactionstoresolvetheproblem.
Table 4-2

Troubleshooting Checklist

Problem

Possible Cause

Recommended Action

All LEDs are OFF.

Loss of power.

Ensure that the module was installed properly


according to the installation instructions in
Chapter 3, and that the host chassis is providing
power.

No Local
Management
Password screen.

Incorrect terminal setup. Refer to the Enterasys Matrix DFE-Platinum


Series Configuration Guide for proper setup
procedures.
Improper console cable
pinouts.

Refer to Appendix A for proper COM port pinouts.

Corrupt firmware image,


or hardware fault.

If possible, attempt to download the image to the


module again. Refer to Appendix B for instructions
to clear NVRAM.

Cannot navigate
beyond Password
screen.

Improper username/
password combination
entered.

If the username/password combination has been


forgotten, refer to Appendix B for instructions on
how to set the mode switch to reset the username/
password combination to the default values.

Cannot contact the


module through inband
management.

IP address not
assigned.

Refer to the Enterasys Matrix DFE-Platinum


Series Configuration Guide for the IP address
assignment procedure.

Port is disabled.

Enable port. Refer to the Enterasys Matrix


DFE-Platinum Series Configuration Guide for
instructions to enable/disable ports.

Host Port policy and/or


management VLAN is
incorrectly configured,
or not configured.

Verify that a management VLAN exists and that it


is associated with the Host Port.

No link to device.

Verify that all network connections between the


network management station and the module are
valid and operating.

Refer to the Enterasys Matrix DFE-Platinum


Series Configuration Guide for information about
Host Port and management VLAN configuration.

If the problem continues, contact Enterasys


Networks for technical support.

DFE-Platinum Series Hardware Installation Guide

4-5

Troubleshooting Checklist

Table 4-2

Troubleshooting Checklist (continued)

Problem

Possible Cause

Recommended Action

Port(s) goes into


standby for no
apparent reason.

Loop condition
detected.

Verify that Spanning Tree is enabled. Refer to the


Enterasys Matrix DFE-Platinum Series
Configuration Guide for the instructions to set the
type of STA.
Review the network design and delete
unnecessary loops.
If the problem continues, contact Enterasys
Networks for technical support.

User parameters
(IP address, device
and module name,
etc.) were lost
when the module
power was cycled,
the front panel
OFFLINE/RESET
switch was
pressed.

Position of Mode switch


(7), Persistent Data
Reset, was changed
sometime before either
cycling power or
pressing the OFFLINE/
RESET switch, causing
the user-entered
parameters to reset to
factory default settings.
Clear Persistent Data
that was set through
Local Management.
The module was moved
either from slot-to-slot
or from chassis-tochassis.

4-6

Troubleshooting

Reenter the lost parameters as necessary. Refer


to the Enterasys Matrix DFE-Platinum Series
Configuration Guide for the instructions to
configure the device.
If the problem continues, contact Enterasys
Networks for technical support.

Overview of DFE-Platinum Module Shutdown Procedure

Overview of DFE-Platinum Module Shutdown Procedure


Caution: Do not remove a DFE-Platinum module from an operating chassis system
before reading the following information and instructions.
Precaucin: Antes de retirar los mdulos DFE-Platinum del chasis en funcionamiento,
lea las siguientes instrucciones y la informacin suministrada.

DFEPlatinummodulesinstalledinaMatrix N3,Matrix N7,orMatrix E7chassisare


interdependentandoperateunderasingleIPaddressasasingle,distributedswitch
system(hardware,databases,andpersistentstorage).Inthisoperatingenvironment,the
DFEPlatinummodulemustshutdowninanorderlyfashiontoensurethattheother
modulesinthesystemandotherdevicesonthenetworkarenotifiedoftheimpending
change.Thedevice(s)canthenmakeintelligentdecisionsandstabilizethenetworkbefore
thechangeismade;therebyincreasingnetworkavailability.
YoucanshutdownaDFEPlatinummoduleinanoperatingsystemusingtheOFFLINE/
RESETswitchshowninFigure 42.Therearetwoprocedurestoshutdowna
DFEPlatinummodule.

Recommendedshutdownprocedure(page48)

Lastresortshutdownprocedure (notrecommended) (page48)

Figure 4-2

OFFLINE/RESET Switch

FAST ENET
7H4202-72
OFFLINE / RESET

COM

CPU
MGMT
1X

GROUP 1

GROUP 2

GROUP 3

1 OFFLINE/RESET switch

DFE-Platinum Series Hardware Installation Guide

4-7

Overview of DFE-Platinum Module Shutdown Procedure

Recommended Shutdown Procedure Using OFFLINE/RESET


Switch
Caution: Do not pull any DFE-Platinum module out of an operating chassis before it has
completed its shutdown routine.
Precaucin: No retire los mdulos DFE-Platinum del chasis en funcionamiento hasta
que no se haya terminado con la rutina de apagado.

BeforepullingaDFEPlatinummoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1 second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating
thatthemoduleisshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthemoduleisina
haltstate.Inthistimeitissafetorestartorremovethemodulefromthechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60
secondsfromthetimetheCPUstartsalternatelyflashingamber/offuntilthedevice
automaticallyrestarts.
Note: The only safe time to pull a DFE-Platinum module out of the chassis is when the
CPU LED is alternately flashing amber/off. Otherwise, system operation will be
interrupted.

Last Resort Shutdown Procedure Using OFFLINE/RESET Switch


Caution: This method of shutting down a DFE-Platinum module is not recommended
except as a last resort, because all processes currently running on the module will be
interrupted resulting in loss of frames.
Precaucin: No se recomienda utilizar este mtodo para apagar los mdulos
DFE-Platinum. Recurra a l slo como ltimo recurso, puesto que interrumpe todos los
procesos del mdulo en funcionamiento, lo que podra resultar prdidas de frames.

ToresetaDFEPlatinummodulewithoutitperforminganorderlyshutdownroutine,
pressandholdthe OFFLINE/RESETswitchforapproximately6seconds.
PullinganyDFEPlatinummoduleoutofthechassisbeforeithasbeenshutdownisnot
recommended.Theonlysafetimetopullamoduleoutofthechassisisafterthe
completionofashutdownandthemanagementLEDisalternatelyflashingamber/off.

4-8

Troubleshooting

A
Specifications
Thisappendixprovidesinformationaboutthefollowing:
For information about...

Refer to page...

DFE-Platinum Module Specifications

A-1

COM Port Pinout Assignments

A-2

Regulatory Compliance

A-3

EnterasysNetworksreservestherighttochangethespecificationsatanytimewithout
notice.

DFE-Platinum Module Specifications


Table A1providestheI/Oports,processorsandmemory,physical,andenvironmental
modulespecificationsfor7H420272.
Table A-1

7H4202-72Specifications

Item

Specification

Ports
Ports 1 through 72

Seventy two, 10BASE-T/100BASE-TX compliant ports via RJ45


connectors.

Processors/Memory
Processor

MPC750CX, 400 MHz processor

Dynamic Random Access


Memory (DRAM)

256 MB (not upgradeable)

FLASH Memory

32 MB (not upgradeable)

DFE-Platinum Series Hardware Installation Guide

A-1

COM Port Pinout Assignments

Table A-1

7H4202-72Specifications (continued)

Item

Specification

Physical
Dimensions

46.43 H x 6.05 W x 29.51 D (cm)


18.28 H x 2.38 W x 11.62 D (in.)

Approximate Weight

Gross: 6.36 kg (14.0 lb) (shipping carton containing


one module)
Net:
5.45 kg (12.0 lb) (one module without packaging)

Predicted hours for Mean Time


Between Failures (MTBF)

For the MTBF hours for these products, refer to the MTBF web
site at http://www.enterasys.com/support/matrix/mtbf.cgi and
search for MTBF.

Environmental
Operating Temperature

5C to 40C (41F to 104F)

Storage Temperature

-30C to 73C (-22F to 164F)

Operating Relative Humidity

5% to 90% (non-condensing)

COM Port Pinout Assignments


TheCOMportisaserialcommunicationsportforlocalaccesstoLocalManagement.
RefertoTable A2fortheCOMportpinassignments.
Table A-2

A-2

Specifications

COM Port Pin Assignments

Pin

Signal Name

Input/Output

Transmit Data (XMT)

Output

Clear to Send (CTS)

Input

Data Set Ready (DSR)

Input

Receive Data (RCV)

Input

Signal Ground (GND)

NA

Request to Send (RTS)

Output

Data Terminal Ready (DTR)

Output

Data Carrier Detect (DCD)

Input

Regulatory Compliance

Regulatory Compliance
The7H420272meetsthesafetyandelectromagneticcompatibility(EMC)requirements
listedinTable A3:
Table A-3

Compliance Standards

Regulatory Compliance

Standards

Safety

UL 60950, CSA C22.2 No. 60950, 73/23/EEC, EN 60950,


IEC 60950.

Electromagnetic Compatibility
(EMC)

47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC,


EN 55022, EN 61000-3-2, EN 61000-3-3, EN 55024,
AS/NZS CISPR 22, VCCI V-3.

DFE-Platinum Series Hardware Installation Guide

A-3

Regulatory Compliance

A-4

Specifications

B
Mode Switch Bank Settings
Caution: Read the appropriate sections to be fully aware of the consequences when
changing switch settings.
Only qualified personnel should change switch settings.
Precaucin: Si desea modificar la configuracin del interruptor, lea las secciones
correspondientes para saber cul ser el resultado de hacerlo.
Estas modificaciones a la configuracin slo debe realizarlas personal calificado.

Figure B1showsthelocationofthemodeswitchesandtheswitchsettingsfornormal
operation.Theseswitchesaresetatthefactorytotheoffpositionandrarelyneedtobe
changed.
Switchdefinitionsandpositionsareasfollows:

Switches1through6ForEnterasysNetworksuseonly.

Switch7ClearPersistentData.ChangingthepositionofthisswitchclearsPersistent
Dataonthenextpowerupofthemodule.Alluserenteredparameters,suchastheIP
address,modulenames,etc.,areresettothefactorydefaultsettings.Oncethemodule
resets,youcaneitherusethefactorydefaultsettingsorreenteryourownparameters.

Switch8ClearAdminPassword.Changingthepositionofthisswitchclearsthe
adminpassword,andrestoresthefactorydefaultpasswordonthenextpowerupof
themodule.Oncethemoduleresets,youcaneitherusethefactorydefaultsettingsor
reenteryourownpassword.
Note: Do not change the position of Switch 8 unless it is necessary to reset the admin
password to its factory default setting.

DFE-Platinum Series Hardware Installation Guide

B-1

B-2

1 Mode switch bank

Mode Switch Bank Settings


24X

DFE

GROUP
SELECT

GROUP

18X

1 2 3

19X

12X
13X

7X

6X

1X

FAST ENET

GROUP 1

GROUP 2

MGMT

CPU

OFFLINE / RESET

7H4202-72

GROUP 3

COM

Figure B-1
Mode Switch Location

1 2 3 4 5 6 7 8

ON

Index
Numerics

100BASE-TX
requirements 2-2
10BASE-T
requirements 2-1
7H4202-72
introduction to 1-2

Installation
connecting to the Network 3-11
module into Matrix E7 or N7 chassis 3-6
module into Matrix N3 chassis 3-9

C
Cable connections
7H4202-72 3-11
Cable specifications
100BASE-TX network 2-2
10BASE-T network 2-1
CLI command
introduction to 1-4
COM port connections
what is needed 3-15
Connecting to the network 3-11
Connectivity
DFE-Platinum module and Ethernet interface
module 1-4
Console port
pinout assignments A-2

D
DFE-Platinum modules and Interface Option
introduction to 1-2
DFE-Platinum series modules
overview of capabilities 1-1
specifications for A-1

E
Electromagnetic Compatibility (EMC)
requirements A-3

G
Getting Help
instructions for xvi
GROUP SELECT button
use of the 4-2
Guide
how to use xiv

L
LANVIEW Diagnostic LEDs
introduction to 1-4
use of 4-1
Local Management
COM port connections 3-15
introduction to 1-4
Login
administratively configured 3-24

M
Management
use of 1-4
Management (MGMT) LED
function of 4-1
Matrix E7 or N7 chassis
module installation into 3-6
Matrix N3 chassis
module installation into 3-9
Module features 1-2

N
Network
connecting to 3-11
Network Requirements
list of 2-1

O
OFFLINE/RESET switch 4-8

P
Pinout assignments
console port A-2
Pinouts
crossover 3-13, 3-14
straight-through 3-13, 3-14

Index-1

Receive LEDs
viewing of 4-2
Regulatory Compliance A-3
Related manuals
obtaining xiv
RESET button. SeeOFFLINE/RESET switch

Unpacking the module 3-2

WebView
introduction to 1-4

Safety requirements A-3


Specifications A-1
DFE-Platinum series module A-1
Standards compatibility 1-4

T
Transmit LEDs
viewing of 4-2
Troubleshooting 4-1
checklist for 4-5

Index-2

V
Viewing Receive and Transmit Activity
instructions for 4-2

Vous aimerez peut-être aussi