Separating walls

This section includes updated information, added


since it was first published in September 2009. Please
see the HOMESPEC 5 update document for details.

Last updated 26/07/2010

Countryside Properties, Lock 38, Stoke-on-Trent


18

Separating wall constructions detailed in


this section are categorised as follows:
- NEW-BUILD

These are Robust Detail constructions that utilise British Gypsum products where appropriate. All Robust
Details have been approved as capable of meeting or exceeding the E1 performance criteria, providing they
are built correctly. Following these specifications means you can be exempt from undertaking Pre-Completion
Testing on a 10% (by type) sample of units built. The Robust Detail scheme applies to new-build houses and
apartments only. Plots must be registered with Robust Details Limited prior to construction.

BRITISH GYPSUM APPROVED SYSTEMS

- NEW-BUILD

These constructions are British Gypsum Approved Systems, which, provided they are built correctly, have
the potential to achieve or exceed E1 performance criteria required for new-build houses and apartment
separating floor constructions and new-build rooms for residential purposes. Pre-Completion Testing must
be executed on a 10% sample (by type) to demonstrate compliance.

BRITISH GYPSUM APPROVED SYSTEMS


RESIDENTIAL PURPOSES

32 - 37

- CONVERSIONS AND NEW-BUILD ROOMS FOR

These constructions are British Gypsum Approved Systems which, provided they are built correctly, have the
potential to achieve or exceed E1 performance criteria required for separating floor constructions created by
material change of use or conversion. Pre-Completion Testing must be executed on a 10% sample (by type) to
demonstrate compliance. They also include constructions for Test and Declare scenario.

GUIDANCE CONSTRUCTIONS

20 - 31

Separating walls

ROBUST DETAILS

38 - 41

- NEW-BUILD AND CONVERSIONS

These constructions are British Gypsum versions of Approved Document E Guidance Constructions, which,
provided they are built correctly, are deemed to achieve the new E1 performance criteria.
Pre-Completion Testing must be executed on a 10% sample (by type) to demonstrate compliance.

42 - 45

Within category 7 of the Code for Sustainable Homes, Health and Wellbeing,
section Hea 2 states that up to four credits are available for achieving higher
standards of sound insulation than those given in Building Regulations
Approved Document E and demonstrating it by using either Pre-Completion
Testing or Robust Details. British Gypsum separating wall solutions can be
specified to achieve enhanced sound insulating performance. This stamp
highlights construction details which have the potential to achieve the number
of credits stated, provided they are built correctly.

19

Separating walls - Robust Details - new-build

Robust Details - new-build


Masonry
Detail
No.

Page

Detail
No.

Page

12

E-WM-13 Masonry - aircrete thin-joint


untied blockwork (render and Gyproc
plasterboard)

27

13

E-WM-14 Masonry - lightweight aggregate


blockwork with 100mm cavity (35mm
Isover RD35 and Gyproc plasterboard)

28

14

E-WM-15 Masonry - aircrete blockwork


(35mm Isover RD35 and Gyproc
plasterboard)

28

E-WM-1 Masonry - dense aggregate


blockwork (wet plaster)

21

E-WM-2 Masonry - lightweight aggregate


blockwork (wet plaster)

21

E-WM-3 Masonry - dense aggregate


blockwork (render and Gyproc plasterboard)

23

E-WM-4 Masonry - lightweight aggregate


blockwork (render and Gyproc plasterboard)

23

E-WM-5 Masonry - Besblock Star Performer


cellular blockwork (render and Gyproc
plasterboard)

24

15

E-WT-1 Timber frame - without


sheathing board

29

E-WM-6 Masonry - aircrete blockwork


(render and Gyproc plasterboard)

24

16

E-WT-2 Timber frame - with sheathing


board

29

E-WM-8 Masonry - lightweight aggregate


blockwork (35mm Isover RD35 and Gyproc
plasterboard)

25

E-WM-9 Masonry - dense aggregate


blockwork (render and Gyproc
plasterboard)

25

17

E-WS-1 Steel frame

30

E-WM-10 Masonry - aircrete thin-joint


blockwork (render and Gyproc
plasterboard)

26

18

E-WS-2 Steel frame GypWall QUIET IWL


(Non-loadbearing)

30

10

E-WM-11 Masonry - lightweight aggregate


blockwork with 100mm cavity (render and
Gyproc plasterboard)

26

19

E-WS-3 Modular build steel frame

31

11

E-WM-12 Masonry - Plasmor Aglite


Ultima (render and Gyproc plasterboard)

27

20

E-WS-4 Steel frame

31

Timber
Detail
No.

Page

Steel
Detail
No.

Page

Key points
Specifying Robust Details avoids the need for Pre-Completion Testing.
Check compatibility of the separating floor with the separating wall. Please refer to page 15 for further information.
Register each plot with Robust Details Limited prior to construction.

www.british-gypsum.com/residential
20

Drywall Academy Tel: 0844 800 1991

SOUND

RD

E-WM-2 Masonry lightweight aggregate


blockwork (wet plaster)

GREEN
GUIDE

SOUND

RD

GREEN
GUIDE

Overall construction nominal width 300mm

Overall construction nominal width 300mm

Dense aggregate cavity block wall minimum


100mm blocks (density 1850 - 2300kg/m3)

Lightweight aggregate cavity block wall


minimum 100mm blocks (density 1350 - 1600kg/m3)

Minimum 75mm cavity between leaves

Minimum 75mm cavity between leaves

Finished with 13mm Thistle plaster


(see table on page 22)

Finished with 13mm Thistle plaster


(see table on page 22)

Refer to flanking details pages 149 - 155

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 149 - 155

Separating walls - Robust Details - new-build

E-WM-1 Masonry dense aggregate


blockwork (wet plaster)

www.british-gypsum.com/residential
21

Undercoat plasters

Background suction

Separating walls - Thistle plaster selector guide

Thistle plaster selector guide

Pre-treatment

Background

High

Aircrete blocks

Thistle
Bonding Coat

Thistle
Browning

Thistle
Hardwall

Thistle
Tough Coat

For smooth,
low suction
or flexible
backgrounds.

For bricks
and blocks
with moderate
suction.

For most masonry


backgrounds. Can be
spray-applied. Higher
impact resistance.

backgrounds. Can be

Suction control usually

Thistle GypPrime in
extreme cases

For most masonry


spray-applied.
Higher coverage.

needed

Lightweight
blocks, e.g. E-WM-2
Dense blocks,
Medium

e.g. E-WM-1

If ThistleBond-it

If ThistleBond-it

If ThistleBond-it

is used

is not used

is not used

Only when bridging

Only when bridging

columns, lintels, etc

columns, lintels, etc

Keyed
Smooth

ThistleBond-it needed

(e.g. paint-grade)

if low suction

Metal lathing

Cast in-situ &

Normal ballast

pre-cast concrete

ThistleBond-it usually
required (unless keyed)

Other aggregates

ThistleBond-it

(limestone granite, etc)

Low

Normal thickness

Thickness recommendations
When using a bonding agent, do not
exceed the thickness given. For other
systems used on walls, if thicknesses in
excess of the recommendation is

11mm to walls, plus 2mm of finish plaster


1.5 - 2hrs

Setting time
Coverage

1.5 - 2hrs

2.75m at 11mm

3.5m at 11mm

(per 25kg bag)

1.5 - 2hrs
2

3.0m at 11mm by hand

3.5m at 11mm by hand

Approx 10% less if

Approx 10% less if

sprayed

sprayed

necessary, extra care is needed to build


it up in a series of fully keyed coats of

Approx. water

nominally 8mm. Thickness over 25mm

requirement

14.0 litres per bag

17.5 litres per bag

1.5 - 2hrs
2

15.0 litres per bag


17.5 litres per bag

normally requires the use of a support


for the plaster, e.g. metal lathing.

Dry set density

Please note, this is not a Robust Detail


approved detail.

12.1kg/m2 at

8.4kg/m2 at

9.3kg/m2 at

8.5kg/m2 at

11mm plus

11mm plus

11mm plus

11mm plus

3.4kg/m2

3.4kg/m2

3.4kg/m2

3.4kg/m2

finish plaster

finish plaster

finish plaster

finish plaster

Thistle Durafinish is a gypsum finish plaster that may be used on a wide range of backgrounds,

Finish plasters

including most undercoat plasters, and to enhance the surface damage resistance of any
British Gypsum partition or wall lining system. It is particularly suited to social housing
applications where occupancy turnover is high. Thistle Durafinish has excellent resistance to
glancing impacts and repeated abrasion, typical of the accidental damage which causes scratching,
gouging or chipping of other wall finishes. This can extend the intervals between maintenance,
helping to reduce costs and maximise the occupiers use of the building. Thistle Durafinish has

Thistle Multi-Finish

Thistle Durafinish

A versatile final
coat plaster for
a wide range of
backgrounds

For improved
resistance to
accidental
damage

similar working characteristics, setting time and suction resistance to Thistle Multi-Finish.

Normal thickness applied


Setting time (longer in colder weather - the use of water to assist final trowelling should be as little as possible)
Minimum temperature (to be maintained until thoroughly dry)

1.5hrs

1.5hrs

2C

2C

10m2

10m2

Approximate water requirement

11.5 litres per bag

11.5 litres per bag

Dry set weight

3.4kg/m2 at 2mm

3.4kg/m2 at 2mm

Coverage per bag

www.british-gypsum.com/residential
22

11mm to walls, plus 2mm of finish plaster

Drywall Academy Tel: 0844 800 1991

SOUND

E-WM-4 Masonry lightweight aggregate


blockwork (render and
Gyproc plasterboard)

GREEN
GUIDE

RD

SOUND

RD

GREEN
GUIDE

Overall construction nominal width 336mm

Overall construction nominal width 336mm

Dense aggregate cavity block wall, minimum


100mm blocks (density 1850 - 2300kg/m3)

Lightweight aggregate cavity block wall, minimum


100mm blocks (density 1350 - 1600kg/m3)

Minimum 75mm cavity between leaves

Minimum 75mm cavity between leaves

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

Refer to flanking details pages 149 - 155

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 149 - 155

Separating walls - Robust Details - new-build

E-WM-3 Masonry - dense


aggregate blockwork
(render and Gyproc
plasterboard)

www.british-gypsum.com/residential
23

Separating walls - Robust Details - new-build

Robust Details - new-build

E-WM-5 Masonry Besblock Star Performer


cellular blockwork (render
and Gyproc plasterboard)
SOUND

RD

E-WM-6 Masonry aircrete blockwork


(render and Gyproc
plasterboard)

GREEN
GUIDE

SOUND

RD

GREEN
GUIDE

C1

Overall construction nominal width 336mm

Overall construction nominal width 336mm

Dense aggregate Besblock 'Star Performer'


cellular cavity block wall minimum 100mm

Aircrete cavity block wall, minimum 100mm blocks


(density 600 - 800kg/m3)

Minimum 75mm cavity between leaves

Minimum 75mm cavity between leaves

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

1 Depending on render specified.

Please refer to www.thegreenguide.org.uk for further information.

Refer to flanking details pages 149 - 155

www.british-gypsum.com/residential
24

Refer to flanking details pages 149 - 155

Drywall Academy Tel: 0844 800 1991

SOUND

RD

E-WM-9 Masonry dense aggregate blockwork


(render and Gyproc
plasterboard)

GREEN
GUIDE

SOUND

GREEN
GUIDE

RD

Overall construction nominal width 320mm

Overall construction nominal width 295mm

Lightweight aggregate cavity block wall, minimum


100mm blocks (density 1350 - 1600kg/m3)

215mm wide single course block wall flat laid


(density 1850 - 2300kg/m3)

Minimum 75mm cavity between leaves

Nominal 15mm (minimum 13mm) sand / cement


render1

35mm Isover RD35 in the cavity


Drylined with 12.5mm Gyproc WallBoard TEN,
15mm Gyproc WallBoard or 12.5mm Gyproc SoundBloc
using DryLiner BASIC system

Separating walls - Robust Details - new-build

E-WM-8 Masonry lightweight aggregate


blockwork (35mm Isover RD35
and Gyproc plasterboard)

Drylined with 15mm Gyproc SoundBloc using


DryLiner BASIC system

1 Sand / cement render may shrink on drying, usually with some cracking,

which can appear several days after application. Therefore, care must be taken
to ensure full drying is complete before drylining.

Refer to flanking details pages 149 - 155

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 156 - 157

www.british-gypsum.com/residential
25

Separating walls - Robust Details - new-build

Robust Details - new-build

E-WM-10 Masonry aircrete thin-joint


blockwork (render and
Gyproc plasterboard)

SOUND

RD

10

E-WM-11 Masonry lightweight aggregate


blockwork with 100mm
cavity (render and Gyproc
plasterboard)

GREEN
GUIDE

SOUND

B1

RD

GREEN
GUIDE

Overall construction nominal width 336mm

Overall construction nominal width 361mm

Aircrete cavity block wall, minimum 100mm


blocks (density 600 - 800kg/m3)

Lightweight aggregate cavity block wall, minimum


100mm blocks (density 1350 - 1600kg/m3)

Wall ties must be Ancon Building Products Staifix HRT4

Minimum 100mm cavity between leaves

Minimum 75mm cavity

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

1 Depending on render specified.

Please refer to www.thegreenguide.org.uk for further information.


Refer to flanking details pages 149 - 155

www.british-gypsum.com/residential
26

Refer to flanking details pages 149 - 155

Drywall Academy Tel: 0844 800 1991

SOUND

RD

12

E-WM-13 Masonry aircrete thin-joint untied


blockwork (render and
Gyproc plasterboard)

GREEN
GUIDE

SOUND

RD

GREEN
GUIDE

B1

Overall construction nominal width 336mm

Overall construction nominal width 336mm

Plasmor Aglite Ultima block wall, minimum


100mm blocks (density 1050kg/m3)

Aircrete cavity block wall, minimum 100mm


blocks (density 600 - 800kg/m3)

Minimum 75mm cavity between leaves

No wall ties are to be inserted in the separating wall

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Minimum 75mm cavity between leaves

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

Nominal 8mm (minimum 6mm) Gyproc Soundcoat Plus

Separating walls - Robust Details - new-build

11

E-WM-12 Masonry Plasmor Aglite Ultima


(render and Gyproc
plasterboard)

Drylined with 12.5mm Gyproc WallBoard using


DryLiner BASIC system

1 Depending on render specified.

Please refer to www.thegreenguide.org.uk for further information.


Refer to flanking details pages 149 - 155

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 149 - 155

www.british-gypsum.com/residential
27

Separating walls - Robust Details - new-build

Robust Details - new-build

13

E-WM-14 Masonry lightweight aggregate


blockwork with 100mm
cavity (35mm Isover RD35
and Gyproc plasterboard)
SOUND

RD

GREEN
GUIDE

SOUND

RD

GREEN
GUIDE

Overall construction nominal width 345mm

Overall construction nominal width 320mm

Lightweight aggregate cavity block wall, minimum


100mm blocks (density 1350 - 1600kg/m3)

Aircrete cavity block wall, minimum


100mm blocks (density 600 - 800kg/m3)

Minimum 100mm cavity between leaves

Minimum 75mm cavity between leaves

35mm Isover RD35 in the cavity

35mm Isover RD35 in the cavity

Drylined with 12.5mm Gyproc WallBoard TEN,


15mm Gyproc WallBoard or 12.5mm Gyproc SoundBloc
using DryLiner BASIC system

Drylined with 12.5mm Gyproc WallBoard TEN,


15mm Gyproc WallBoard or 12.5mm Gyproc SoundBloc
using DryLiner BASIC system

Refer to flanking details pages 149 - 155

www.british-gypsum.com/residential
28

14

E-WM-15 Masonry aircrete blockwork (35mm


Isover RD35 and Gyproc
plasterboard)

Refer to flanking details pages 149 - 155

Drywall Academy Tel: 0844 800 1991

SOUND

RD

FIRE

Min.
60 mins BS

GREEN
GUIDE

A+

16

E-WT-2 Timber frame with sheathing board

SOUND

RD

FIRE

Min.
60 mins BS

GREEN
GUIDE

A+ or A1

Overall construction nominal width 300mm

Overall construction nominal width 300mm

Cavity width minimum 240mm, gap of minimum


50mm between frames

Minimum 240mm width between the inner


facings of the linings

65mm Isover APR 1200 or 90mm Isover Frame Batt 32


positioned between the studs in each timber frame

Minimum 50mm gap between sheathing panels

Board options:
Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc WallBoard each side,
or Double layer of 15mm Gyproc SoundBloc each side,
or Double layer of 15mm Gyproc FireLine each side,
or Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc FireLine each side

Separating walls - Robust Details - new-build

15

E-WT-1 Timber frame without sheathing board

65mm Isover APR 1200 or 90mm Isover Frame Batt 32


positioned between the studs in each timber frame
Board options:
Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc WallBoard each side,
or Double layer of 15mm Gyproc SoundBloc each side,
or Double layer of 15mm Gyproc FireLine each side,
or Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc FireLine each side
1 Depending on sheathing board specified. Please refer to

www.thegreenguide.org.uk for further information.

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with Robust Details Limited.Based on 80% Load Ratio.
Refer to flanking details pages 163 - 166

email: bgtechnical.enquiries@bpb.com

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with Robust Details Limited.Based on 80% Load Ratio.
Refer to flanking details pages 163 - 166

www.british-gypsum.com/residential
29

Separating walls - Robust Details - new-build

Robust Details - new-build

17

18

E-WS-1 Steel frame

SOUND

RD

FIRE

Min.
60 mins BS1

GREEN
GUIDE

SOUND

RD

E-WS-2 Steel frame


GypWall QUIET IWL
(Non-loadbearing)

FIRE

Min.
90 mins BS

GREEN
GUIDE

HEIGHTS
Max. 3900mm at 600mm
centres using Gypframe
60 I 70 I Studs

PSR A216007

For use in lightweight steel frame housing or


flats / apartments

Overall construction nominal width 250mm


Minimum cavity width 190mm

Minimum cavity width 200mm


Loadbearing studs (by others)

Gypframe I Studs minimum 60mm depth


(no bracing between leaves)

Overall construction nominal width 263mm

100mm Isover APR 1200 positioned between the frames

50mm Isover Frame Batt 32 positioned


between the frames or 65mm Isover APR 1200
positioned between the studs in each frame

Board options:
Double layer of 15mm Gyproc SoundBloc each side
(for 90 minutes BS and EN fire resistance)
or
Double layer of 15mm Gyproc SoundBloc each
side overboarded with one layer of 12.5mm
Gyproc FireLine each side (for 120 minutes BS and EN
fire resistance)

Board options:
Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc WallBoard each side,
or
Double layer of 15mm Gyproc SoundBloc each side.

1 Subject to manufacturers substantiation based on their loadbearing stud.

Refer to flanking details pages 167 - 171

www.british-gypsum.com/residential
30

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used , and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with Robust Details Limited.
Refer to flanking details pages 172 - 176

Drywall Academy Tel: 0844 800 1991

SOUND

RD

FIRE

60 mins
1
BS

GREEN
GUIDE

B or C2

20

E-WS-4 Steel frame

SOUND

RD

FIRE

GREEN
GUIDE

60 mins
1
BS

Only for use in lightweight steel frame housing or


flats / apartments

For use in lightweight steel frame housing or


flats / apartments

Overall construction nominal width 264mm

Minimum cavity width 250mm

Minimum 72mm or 100mm loadbearing studs


(by others)

Overall construction nominal width 313mm

Separating walls - Robust Details - new-build

19

E-WS-3 Modular build


steel frame

Minimum 75mm loadbearing C studs (by others)

Minimum 40mm gap between sheathing panels


Minimum 75mm mineral Isover TS48 Slab (45kg/m3)
positioned between the studs
Board options:
72mm studs
Double layer of 15mm Rigidur H
100mm studs
Double layer of 12.5mm Rigidur H

90mm Isover Frame Batt 32 positioned between


the frames
Board options:
Inner layer of 19mm Gyproc Plank,
outer layer of 12.5mm Gyproc WallBoard each side,
or
Double layer of 15mm Gyproc SoundBloc each side.

1 Subject to manufacturers substantiation based on their loadbearing stud.


2 Depending on sheathing board specified. Please refer to
www.thegreenguide.org.uk for further information.

1 Subject to manufacturers substantiation based on their loadbearing stud.

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used , and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with Robust Details Limited.

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used , and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with Robust Details Limited.

Refer to flanking details pages 167 - 171

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 167 - 171

www.british-gypsum.com/residential
31

Separating walls - British Gypsum Approved Systems - new-build

British Gypsum Approved Systems - new-build


Steel
Detail
No.

Page

Detail
No.

Page

21

GypWall CLASSIC with Gypframe AcouStuds

33

27

GypWall QUIET SF

36

22

GypWall CLASSIC with Gypframe AcouStuds

33

28

GypWall QUIET IWL

36

23

GypWall QUIET

34

29

GypWall QUIET IWL

37

24

GypWall QUIET

34

Masonry
Detail
No.

25

GypWall QUIET SF

35

26

GypWall QUIET SF - with additional service


zone created with GypLyner UNIVERSAL

35

30

Page

Masonry walls and GypLyner UNIVERSAL


lining

37

Key points

All new-build specifications are suitable for conversion projects.


Pre-Completion Testing is required when specifying British Gypsum Approved Systems.
Flanking details should be fully considered during the design and construction process. Refer to pages 160 - 179.

Specification tips

GypWall QUIET SF is a narrow solution that maximises available space.


GypWall QUIET is a twin frame solution that provides flexibility to incorporate columns within the
separating wall cavity.
GypWall CLASSIC is a cost effective, single frame solution.

www.british-gypsum.com/residential
32

Drywall Academy Tel: 0844 800 1991

22

PRE-COMPLETION TESTING

PRE-COMPLETION TESTING

- NEW-BUILD

56 dB
Rw + Ctr

FIRE

90 mins BS

- NEW-BUILD

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

GypWall CLASSIC with


Gypframe AcouStuds

HEIGHTS

SOUND

FIRE

57 dB
Rw + Ctr

Max. 8100mm at
600mm centres

90 mins BS

HEIGHTS

Max. 8100mm at
600mm centres

PSR A206A255

PSR A206A243

Overall construction nominal width 208mm

Overall construction nominal width 208mm

Gypframe 146 AS 50 AcouStud at 600mm centres

Gypframe 146 AS 50 AcouStud at 600mm centres

50mm Isover APR 1200 in the cavity

150mm Isover APR 1200 in the cavity

Lined with a double layer of 15mm Gyproc SoundBloc


each side

Lined with a double layer of 15mm Gyproc SoundBloc


each side

Alternatively:

Alternatively:

Lined with a double layer of 15mm Gyproc DuraLine


for 120 minutes fire resistance

Lined with a double layer of 15mm Gyproc DuraLine


for 120 minutes fire resistance

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.

Refer to flanking details pages 177 - 179

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 177 - 179

Separating walls - British Gypsum Approved Systems - new-build

21

GypWall CLASSIC with


Gypframe AcouStuds

www.british-gypsum.com/residential
33

Separating walls - British Gypsum Approved Systems - new-build

British Gypsum Approved Systems - new-build

23

24

GypWall QUIET

PRE-COMPLETION TESTING

- NEW-BUILD

PRE-COMPLETION TESTING

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

53 dB
Rw + Ctr

FIRE

90 mins BS

GypWall QUIET

- NEW-BUILD

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

HEIGHTS

SOUND

57 dB
Rw + Ctr

Max. 7500mm at 600mm


centres, cross-braced at
1200mm centres

PSR A216009
PSR A216010

FIRE

90 mins BS

HEIGHTS
Max. 7500mm at 600mm
centres, cross-braced at
1200mm centres

PSR A216011

Overall construction nominal width 200mm

Overall construction nominal width 250mm

Two frames of 48mm Gypframe C Stud at


600mm centres, cross braced at 1200mm centres

Two frames of 48mm Gypframe C Stud at


600mm centres, cross braced at 1200mm centres

Cavity width of 140mm

Cavity width of 190mm

50mm Isover APR 1200 positioned between the frames

75mm Isover High Performance Acoustic Slab


positioned between the frames

Lined with a double layer of 15mm Gyproc SoundBloc


each side

Lined with a double layer of 15mm Gyproc SoundBloc


each side

Alternatively:
Lined with a double layer of 15mm Gyproc FireLine
for 120 minutes fire resistance
NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.

Refer to flanking details pages 172 - 176

www.british-gypsum.com/residential
34

Alternatively:
Lined with a double layer of 15mm Gyproc DuraLine
for 120 minutes fire resistance
NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.

Refer to flanking details pages 172 - 176

Drywall Academy Tel: 0844 800 1991

26

PRE-COMPLETION TESTING

PRE-COMPLETION TESTING

- NEW-BUILD

FIRE

54 dB
Rw + Ctr

90 mins BS

- NEW-BUILD

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

GypWall QUIET SF
with additional
service zone created with
GypLyner UNIVERSAL

HEIGHTS
Max. 4200mm at
600mm centres

FIRE

SOUND

54 dB
Rw + Ctr

90 mins BS

HEIGHTS
Max. 4200mm at
600mm centres

PSR A316009

Overall construction nominal width 148mm

Base separating wall, GypWall QUIET SF, as per detail 25

70mm Gypframe C Studs at 600mm centres


with Gypframe RB1 Resilient Bar at 600mm centres
fixed to one side of the studs

A wall lining with:

50mm Isover APR 1200 positioned in the cavity


Lined with a double layer of 15mm Gyproc SoundBloc
each side
Alternatively:
Lined with a double layer of 15mm Gyproc DuraLine
for 120 minutes fire resistance

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.
Refer to flanking details pages 177 - 179

email: bgtechnical.enquiries@bpb.com

Minimum 70mm cavity


Minimum 50mm Isover APR 1200 in the cavity
Single layer of 15mm Gyproc SoundBloc installed on
one or both sides of the base GypWall QUIET SF
construction (for base construction refer to detail 25)

Separating walls - British Gypsum Approved Systems - new-build

25

GypWall QUIET SF

This solution can be used without lowering the


acoustic performance of GypWall QUIET SF

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.
Refer to flanking details pages 177 - 179

www.british-gypsum.com/residential
35

Separating walls - British Gypsum Approved Systems - new-build

British Gypsum Approved Systems - new-build

27

28

GypWall QUIET SF

PRE-COMPLETION TESTING

PRE-COMPLETION TESTING

- NEW-BUILD

53 dB
Rw + Ctr

FIRE

120 mins BS

HEIGHTS
Max. 4200mm at
600mm centres

PSR Q606040

SOUND

58 dB
Rw + Ctr

FIRE

90 mins BS

HEIGHTS
Max. 2800mm at
600mm centres

PSR A216014

Overall construction nominal width 148mm

Overall construction nominal width 200mm

70mm Gypframe C Studs at 600mm centres


with Gypframe RB1 Resilient Bar at 600mm centres
fixed to one side of the studs

Two frames of Gypframe 48 I 50 I Studs at


600mm centres

50mm Isover APR 1200 positioned in the cavity


Lined with an inner layer of 15mm Gyproc FireLine
and an outer layer of 15mm Gyproc DuraLine

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.

Refer to flanking details pages 177 - 179

www.british-gypsum.com/residential
36

- NEW-BUILD

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

GypWall QUIET IWL

Cavity width of 140mm wide


50mm Isover APR 1200 positioned in the cavity
Lined with a double layer of 15mm
Gyproc SoundBloc each side

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled, or
skimmed according to British Gypsums recommendations. The quoted performances
are achieved only if British Gypsum components are used throughout, and the companys
fixing recommendations are strictly observed. Any variation in the specifications should
be checked with British Gypsum.
Refer to flanking details pages 172 - 176

Drywall Academy Tel: 0844 800 1991

30

PRE-COMPLETION TESTING

- NEW-BUILD

PRE-COMPLETION TESTING

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

62 dB
Rw + Ctr

FIRE

90 mins BS

Masonry walls and


GypLyner UNIVERSAL lining

- NEW-BUILD

BRITISH GYPSUM APPROVED SYSTEM (45 dB DnTw + Ctr)

SOUND

HEIGHTS

59 dB
Rw + Ctr

Max. 3300mm at
600mm centres

PSR B226005

PSR A216013

Core masonry element mass per unit area


minimum 200kg/m2, e.g. 100mm high density
aggregate blocks

Overall construction nominal width 250mm


Two frameworks of Gypframe 60 I 50 I Stud
Cavity width of 190mm wide
100mm Isover APR 1200 in the cavity

GypLyner UNIVERSAL wall lining to one side of wall with


minimum 85mm cavity (framing at 600mm centres)

Lined with a double layer of 15mm


Gyproc SoundBloc each side

Lined with double layer of 12.5mm Gyproc


SoundBloc, 50mm Isover APR 1200 in the cavity

Separating walls - British Gypsum Approved Systems - new-build

29

GypWall QUIET IWL

Other side lined with either 12.5mm Gyproc WallBoard


on the DriLyner BASIC system or 13mm Thistle plaster
finish (see table, page 22)
Nominal width 232mm (drylined) or 223mm (plastered)
NB Sound insulation performance are for imperforate partitions, walls and
ceilings incorporating boards with all joints taped and filled, or skimmed according
to British Gypsums recommendations. The quoted performances are achieved only
if British Gypsum components are used throughout, and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with British Gypsum.

Refer to flanking details pages 172 - 176

email: bgtechnical.enquiries@bpb.com

NB Sound insulation performance are for imperforate partitions, walls and


ceilings incorporating boards with all joints taped and filled, or skimmed according
to British Gypsums recommendations. The quoted performances are achieved only
if British Gypsum components are used throughout, and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with British Gypsum.
Refer to flanking details pages 160 - 162

www.british-gypsum.com/residential
37

Separating walls - British Gypsum Approved Systems - conversions

British Gypsum Approved Systems - conversions


Conversions and new-build rooms for residential purposes

Steel
Detail
No.

Timber
Page

Detail
No.

34

31

GypWall CLASSIC

39

32

GypWall QUIET SF

39

Page
Timber stud and Gypframe RB1
Resillient Bar

Masonry
Detail
No.

33

GypWall QUIET IWL

40

40

Page

35

Masonry walls and DriLyner SI

41

36

Masonry walls and GypLyner UNIVERSAL


lining

41

Specification tips

When using systems incorporating Gypframe RB1 Resilient Bar, ensure lining board fixings are suitably
positioned and of the appropriate length to avoid contact with the framing sections behind the Gypframe
RB1 Resilient Bars.
When installing Isover insulation, ensure that the insulation covers the whole wall area without gaps. Particular
care should be taken to ensure correct installation.
Where service penetrations are unavoidable, including light switches and socket box installations, ensure
the correct detailing is followed to prevent loss of acoustic, fire and air leakage performance.
Always stagger joints in wall linings to avoid air paths which will allow the transmission of sound.

Key points

All conversion specifications are suitable for rooms designed for residential purpose, for example, hotels
and student accommodation.
Pre-Completion Testing is required when specifying British Gypsum Approved Systems.
Flanking details should be fully considered during the design and construction process.

www.british-gypsum.com/residential
38

Drywall Academy Tel: 0844 800 1991

32

PRE-COMPLETION TESTING

PRE-COMPLETION TESTING

- CONVERSIONS

53 dB
Rw + Ctr

FIRE

90 mins BS

- CONVERSIONS

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

SOUND

GypWall QUIET SF

HEIGHTS

SOUND

53 dB
Rw + Ctr

Max. 4000mm at
600mm centres

FIRE

60 mins BS

HEIGHTS
Max. 4000mm at
600mm centres

PSR A316008

PSR A206243

Overall construction nominal width 208mm

Overall construction nominal width 138mm

Gypframe 146 S 50 C Studs at 600mm centres

Gypframe 70 S 50 C Studs at 600mm centres


with Gypframe RB1 Resilient Bar at 600mm centres
fixed to one side of the stud

50mm Isover APR 1200 in the cavity


Lined with a double layer of 15mm
Gyproc SoundBloc

50mm Isover APR 1200 positioned in the cavity


Lined each side with a double layer of 12.5mm
Gyproc SoundBloc

Separating walls - British Gypsum Approved Systems - conversions

31

GypWall CLASSIC

Alternatively:
Lined with a double layer of 15mm
Gyproc DuraLine for 120 minutes fire resistance
NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled,
or skimmed according to British Gypsums recommendations. The quoted
performances are achieved only if British Gypsum components are used throughout,
and the companys fixing recommendations are strictly observed. Any variation in the
specifications should be checked with British Gypsum.

Refer to flanking details pages 177 - 179

email: bgtechnical.enquiries@bpb.com

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled,
or skimmed according to British Gypsums recommendations. The quoted
performances are achieved only if British Gypsum components are used throughout,
and the companys fixing recommendations are strictly observed. Any variation in the
specifications should be checked with British Gypsum.
Refer to flanking details pages 177 - 179

www.british-gypsum.com/residential
39

Separating walls - British Gypsum Approved Systems - conversions

British Gypsum Approved Systems - conversions

33

34

GypWall QUIET IWL

PRE-COMPLETION TESTING

- CONVERSIONS

PRE-COMPLETION TESTING

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

SOUND

52 dB
Rw + Ctr

FIRE

120 mins

- CONVERSIONS

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

SOUND

HEIGHTS
2800mm at 600mm
centres using 48mm
Gypframe I Studs1

51 dB
Rw + Ctr

FIRE

90 mins BS

PSR A046007

PSR A216006

Overall construction nominal width 250mm

Overall construction nominal width 151mm

Minimum cavity width 190mm

38mm x 75mm timber stud at 600mm centres with


Gypframe RB1 Resilient Bar at 600mm centres fixed
to one side of the stud

Gypframe I Studs minimum 48mm depth


(no bracing between leaves)

75mm Isover APR 1200 in the cavity

100mm Isover APR 1200 in the cavity

Lined with a double layer of 15mm Gyproc SoundBloc

Lined with a double layer of 15mm


Gyproc FireLine

1 For other stud sizes / maximum heights, contact the British Gypsum

Drywall Academy.

NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled,
or skimmed according to British Gypsums recommendations. The quoted
performances are achieved only if British Gypsum components are used throughout,
and the companys fixing recommendations are strictly observed. Any variation in the
specifications should be checked with British Gypsum.
Refer to flanking details pages 172 - 176

www.british-gypsum.com/residential
40

Timber stud and


Gypframe RB1
Resilient Bar

NB For existing timber stud, partitions lined with lath and plaster, this specification
could be used after complete removal of the lath and plaster. If the lath and plaster is
in good condition then it could remain in place on the non-resilient bar side, with the
double layer 15mm Gyproc SoundBloc screw-fixed through the lath and plaster into
the timber framing.
NB The fire resistance and sound insulation performance are for imperforate
partitions, walls and ceilings incorporating boards with all joints taped and filled,
or skimmed according to British Gypsums recommendations. The quoted
performances are achieved only if British Gypsum components are used throughout,
and the companys fixing recommendations are strictly observed. Any variation in the
specifications should be checked with British Gypsum.
Refer to flanking details pages 177 - 179

Drywall Academy Tel: 0844 800 1991

36

PRE-COMPLETION TESTING

- CONVERSIONS

Masonry walls and


GypLyner UNIVERSAL lining

PRE-COMPLETION TESTING

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

- CONVERSIONS

BRITISH GYPSUM APPROVED SYSTEM (43 dB DnTw + Ctr)

SOUND

SOUND

53 dB
Rw + Ctr

PSR B160018

55 dB
Rw + Ctr

PSR B226003

Improvement when lining to one side of a core


masonry element (mass per unit area circa 200kg/m2)
with plaster the other side

Improvement when lining to one side of a core


masonry element (mass per unit area circa 200kg/m2)
with plaster the other side

52mm Gyproc TriLine Rw = 13 dB and Rw + Ctr = 9 dB

GypLyner UNIVERSAL, minimum 35mm cavity, with 2 x


12.5mm Gyproc SoundBloc, 25mm Isover APR 1200
Rw = 13 dB and Rw + Ctr = 11 dB

NB Sound insulation performance are for imperforate partitions, walls and


ceilings incorporating boards with all joints taped and filled, or skimmed according
to British Gypsums recommendations. The quoted performances are achieved only
if British Gypsum components are used throughout, and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with British Gypsum.

NB Sound insulation performance are for imperforate partitions, walls and


ceilings incorporating boards with all joints taped and filled, or skimmed according
to British Gypsums recommendations. The quoted performances are achieved only
if British Gypsum components are used throughout, and the companys fixing
recommendations are strictly observed. Any variation in the specifications should be
checked with British Gypsum.

Refer to flanking details pages 160 - 162

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 160 - 162

Separating walls - British Gypsum Approved Systems - conversions

35

Masonry walls and


DriLyner SI

www.british-gypsum.com/residential
41

Separating walls - Guidance constructions - new-build and conversions

Guidance constructions - new-build and conversions

Masonry
Detail
No.

Page

37

Dense aggregate cavity masonry


(wall type 2.1)

43

38

Lightweight aggregate cavity masonry


(wall type 2.2)

43

39

Masonry between independent panels


(wall type 3.1) with GypLyner IWL

44

40

Solid masonry (wall type 1)

44

41

Framed walls with absorbent material


(wall type 4) (Loadbearing)

45

Key points
Flanking details should be fully considered during the design and construction process.
Pre-Completion Testing is required when specifying Approved Document E Guidance Constructions.
When installing Isover insulation, ensure that the insulation covers the whole wall area without gaps.
Particular care should be taken to ensure correct installation.
Where service penetrations are unavoidable, including light switches and socket boxes, etc.
Ensure the correct detailing is followed to prevent loss of acoustic, fire and air leakage performance.
Always stagger joints in wall linings to avoid air paths which will allow the transmission of sound.
For masonry constructions, ensure all blockwork joints are fully filled with mortar.

www.british-gypsum.com/residential
42

Drywall Academy Tel: 0844 800 1991

PRE-COMPLETION TESTING - NEW-BUILD


GUIDANCE CONSTRUCTION

PRE-COMPLETION TESTING - NEW-BUILD


GUIDANCE CONSTRUCTION

SOUND

38

Lightweight aggregate
cavity masonry
(wall type 2.2)

GREEN
GUIDE

Guidance
Construction

SOUND

GREEN
GUIDE

Guidance
Construction

Dense aggregate cavity block wall, minimum


50mm cavity between leaves

Lightweight aggregate cavity block wall,


minimum 75mm cavity between leaves

Finished with 13mm Thistle plaster finish on


each face (see table, page 22)

Finished with 13mm Thistle plaster finish on


each face (see table, page 22)

Total mass per unit area 415kg/m2 (minimum)

Total mass per unit area 300g/m2 (minimum)

Refer to flanking details pages 149 - 155

email: bgtechnical.enquiries@bpb.com

Refer to flanking details pages 149 - 155

Separating walls - Guidance constructions - new-build and conversions

37

Dense aggregate cavity


masonry
(wall type 2.1)

www.british-gypsum.com/residential
43

Guidance constructions - new-build and conversions


Separating walls - Guidance constructions - new-build and conversions

39

40

Masonry between
independent panels
(wall type 3.1) with
GypLyner IWL

PRE-COMPLETION TESTING - NEW-BUILD


GUIDANCE CONSTRUCTION

PRE-COMPLETION TESTING - NEW-BUILD


GUIDANCE CONSTRUCTION

SOUND
Guidance
Construction

Solid masonry
(wall type 1)

GREEN
GUIDE

SOUND
Guidance
Construction

Core masonry element minimum, mass per unit area


300kg/m2
Lined each side with GypLyner IWL

GREEN
GUIDE

Dense aggregate blocks laid flat


Finished with 13mm Thistle plaster finish on each
face (see table, page 22)
Minimum total mass per unit area 415kg/m2

Lined with a double layer of 12.5mm


Gyproc WallBoard TEN each side,
or
12.5mm Gyproc SoundBloc
The lining should be set 10mm away from the
masonry core, utilising a Gypframe 48 I 50 I Stud
Maximum height of 2700mm when using Gypframe
48 I 50 I Studs at 600mm centres
Lining cavity width of 60mm when using
Gypframe 48 I 50 I Studs

Refer to flanking details pages 158 - 159

www.british-gypsum.com/residential
44

Refer to flanking details pages 158 - 159

Drywall Academy Tel: 0844 800 1991

Separating walls - Guidance constructions - new-build and conversions

41

Framed walls with


absorbent material
(wall type 4.1)
(Loadbearing)

PRE-COMPLETION TESTING - NEW-BUILD


GUIDANCE CONSTRUCTION

SOUND
Guidance
Construction

GREEN
GUIDE

A+

Overall construction nominal width 250mm


Cavity width minimum 200mm
Studs at 600mm centres
Plywood sheathing may be used in the cavity as
required for structural purposes
Lined with a double layer of 12.5mm
Gyproc WallBoard TEN,
or
Double layer of 12.5mm Gyproc SoundBloc
25mm Isover APR 1200 positioned between the
studs in each timber frame

Refer to flanking details pages 163 - 166

email: bgtechnical.enquiries@bpb.com

1
www.british-gypsum.com/residential
45

Vous aimerez peut-être aussi