HVAC Blog | HVAC Talk & Trends | HVAC Maintenance Tools

| Power Generation Maintenance


The Food Service Modernization Act compliance dates have arrived and that likely means?significant
changes to your?current operating procedures. In this podcast, Evan D. Reyes, National Account
Manager at Goodway Technologies, discusses?key requirements relating to?hazard analysis,
preventative controls and food sanitation for both big and small facilities. Watch?this?podcast
overview?below to get complete access or learn how to take conveyor belt cleaning to a new level.
In this "Just Venting Podcast," Ray Field, the Director of Goodway Liquid Solutions, discusses the
physical and financial impact of scale build-up on boilers, chillers and cooling towers. Ray also
provides tips on how to avoid expensive repairs, improve energy efficiency and decrease electrical
costs by implementing an effective maintenance plan.
Chiller units -- open loop or closed loop -- naturally experience performance degradations over time.
As noted by Facilities Net, chillers and companion condenser units are often the single biggest
energy spend in an organization and despite predictive maintenance methods such as vibration
analysis, infrared thermography and rotor bar testing, scale and foiling still occurs. Here's a look at
the impact of scale on your condenser system and the steps you can take to maximize efficiency.
Sources and Spending
To limit the impact of condenser fouling you need to identify the source. If you're running an open
loop system, the biggest problem comes from the water source itself -- minerals and other
particulate matter can quickly cause scale to build up if water isn't properly treated before being
transferred to the chiller. In closed loop systems, the cooling tower itself becomes the key source of
contaminants, which in turn make their way into condensers and drive the growth of scale build-up.
As noted by Innovas even small amounts of scale in your system result in big impacts. For example, a
2000 ton chiller running 3000 hours a year with an energy efficiency rating of 0.65 kW/ton gives an
energy cost of $0.09 kW/hr. With just 0.006 of scale, energy costs jump $14,000 per year. At 0.036
inches, extra costs skyrocket to $95,000 per year.
Saving the System
So how do you maximize chiller efficiency and ensure you're not wasting money on fouled
condensers? ACHR News and Facilities Net suggest a few straightforward methods, including:
Increased Chill Water Temperature -- Even increasing the chill ductless air water temperature a
degree offers a 2 to 4 percent energy efficiency increaseTreat Water Aggressively -- ACHR
recommends combining an aggressive biocide plan with scale and corrosion protection practices to
limit scale production.Ensure a Leak-Free Unit -- Leaks in condenser and chiller units introduce air
into the system which significantly lowers efficiency and can also cause interior rust build-up. In
high-pressure units, leaks can release hazardous gasses into the nearby atmosphere.Keep Daily Logs
-- Keeping track of day-to-day condenser performance allows you to conduct regular data
comparison and ensure you're meeting efficiency targets.
Despite best efforts, chances are you will need to deal with scale eventually. Best bet? Leverage a
high-quality chemical descaling treatment in early spring or winter months when condensers and

chillers aren't on high-use cycles. Worth noting, however, is that even minor scale build-up always
trumps existing descale plans since the energy loss simply isn't worth waiting for regular
maintenance. While this may mean an unexpected shutdown of chillers for several days and a
commensurate drop in productivity, this cost is minimal compared with the exponential expense of
fouled condenser systems.
Scale is a cooling tower's worst enemy: Design an effective PM procedure and descale on demand to
ensure maximum efficiency.?
Next Steps:
Subscribe to our Seasonal HVAC System Efficiency Podcast Series. This time of year our focus is on
Boilers, Chillers and Cooling Towers.

We came. We saw. We introduced over 10,879 HVAC&R industry professionals to some of the most
advanced tube cleaners, cooling tower cleaning systems and coil cleaners that Goodway has to offer
in Latin America, at this year's AHR Expo Mexico. Thanks to everyone who stopped by booth 912 to
witness what Goodway has to offer for easier, faster and more effective HVAC maintenance cleaning.
Stay tuned for 2018 AHR Expo Mexico heating & cooling in Mexico City, and for more information
on Goodway's innovative maintenance solutions, clic aqui.
Boiler cleaning is something most companies don't want to think about -- if boilers are working
within operational limits it's often easier to keep up with smaller preventative maintenance (PM)
tasks but put off a total chemical clean until performance starts to suffer. The problem? Once scale
forms on boiler surfaces both fuel and efficiency losses quickly ramp up. Here's a look at the cost of
scale and the case for regular chemical cleaning.
Fuel Failures
What's the real impact of scale on boiler efficiency? According to the Department of Energy (DoE),
even "normal" scale at 1/32 inch thickness produced by low-pressure applications leads to a two
percent fuel loss. In high pressure applications, the resulting iron plus silica deposits can result in
fuel losses of up to seven percent. And while two percent may not. sound like much, the EPA offers a
helpful example: A firetube boiler using 450,000 MMBtu of fuel (at $8.00 per MMBtu) over 8000

hours per year with 1/32 inch of normal scale means a yearly operating cost spike of over $70,000.
As noted by research from NC State University, the reduced heat conductivity of scale leads to big
problems in agriculture applications: If left untreated, ? inch thick scale can lead to 70 percent
increased fuel usage and significantly reduce overall boiler efficiency. Simply put? Even minimal
scaling is a major problem.
Calculating Clean
Chemical cleanings aren't cheap -- and require you to shut down boiler operations for at least a day.
So how do you know when it's worth investing the time and money and when you can afford to wait?
As noted by ACHR News it's a good idea to conduct regular visual inspections of boiler tubes to
check for scale build-up. Regular monitoring of flue gas temperature can also indicate a problem -- if
the temperature rises when boiler load and excess air are held constant, scale is the likely culprit.
Other reasons to consider a chemical clean include one or more system failures due to corrosion, or
if you replace a significant amount (more than 10 percent) of your boiler tubing. According to
Hartford Steam Boiler, evidence-based assessments are always the best way to determine chemical
cleaning needs; while time-based cleanings have the benefit of simplicity and regularity they can't
take into account the myriad factors -- such as water chemistry, frequency of startup, shutoff and
blowdown -- which contribute to scale formation.
Once you've identified scale, the next step is selecting a chemical solution and deploying the
product. Best bet here? Draft and follow a solid set of best practices to ensure your chemical clean
fully penetrates and dissolves scale before you flush and re-ignite boiler systems. Given the cost and
time investment associated with chemical descaling, it's worth doing right the first time.
Bottom line? Scale is expensive and ruins boiler efficiency. Rely on evidence-based methods to
detect build-up and immediately deploy a full chemical descale if your boiler shows any signs of
scale.
Next Steps:
Subscribe to our Seasonal HVAC System Efficiency Podcast Series. This time of year our focus is on
Boilers, Chillers and Cooling Towers.
Also, check out our descaler calculater!
http://www.goodway.com/hvac-blog/