Control devices
Selection guide - Impulse switches

Selection guide - Contactors


Selection guide - Time switches and Digital programmer

5-7

Technical information - Impulse switches

Technical information - Contactors

10-11

Command devices
Selection guide - Staircase lighting time switch and Bell+buzzer+transformer

12

Selection guide - Safety transformers

13

Manual motor starters


Selection guide

14

Enclosures for manual motor starters

15

Enclosure mounting accessories

15

Technical information

16
17

Tripping characteristics and Dimensions

4
5

TemSwitch Isolating switches


Selection guide and Dimensions

18

Technical information

19

TemMaster Surge protectors

/ TemControl / 3

Selection guide

20

Technical information
Wiring diagrams

21
22

Dimensions

23

Selection guide
TemControl
Impulse switches

TR Impulse switches
Reference

Contacts

TR1610
TR3210
TR1611
TR1620
TR3220

1 NO
1 NO
1 change-over
2 NO
2 NO

Pack: 1 unit

In
(A)
16A
32A
16A
16A
32A

250V~
250V~
250V~
250V~
250V~

No. of
modules
1
1
1
1
1

To control by an impulse all types of electrical circuit: lighting,


machinery, air cooling, ...

1 NO

1 CO

1-pole and 2-pole (16A or 32A) impulse relays


Contacts: 16A: NO, changeover - 32A: NO
Main features
Front handle for manual operation, showing actual position of the
contacts.
Sealable clamping terminals with unlosable screws.
Maximum cable cross-section: 10 mm
Switching capacity AC1: 16A & 32A - 250/400VAC
Command voltages: 230VAC/115VDC.
Electrical life at full load: over 400.000 operations
In accordance with CE and EN 60669-2-2.

2 NO

BT Main contact blocks for TR Impulse switches


Reference
BT1620
BT3220

Contacts

In
(A)

No. of
modules

2 NO
2 NO

16A - 400V~
32A - 400V~

1
1

2 NO

Pack: 1 unit

2 pole 16A or 32A device, to be clipped on the left side of the


impulse switch, without need of any screw or additional wiring.

BA Auxiliary contact blocks


Reference
BA0510
BA0520

Contacts

In
(A)

No. of
modules

1 changeover
1NO+1NC

5A - 250V~
5A - 250V~

1/2
1/2

1 CO

Pack: 1 unit

When added to a device, BA blocks make additional auxiliary


contacts available for a remote signal, or to synchronously control
other devices.
The same blocks may be used with TR impulse switches and
CNR - CNO contactors series.
Up to 2 blocks may be added to a single device, and when a
main contact block is already fitted, only 1 auxiliary contact block
can be added.
Blocks are clipped on the left side of an impulse switch or of a
main contact block, without need of any screw or additional
wiring.
Switching capacity AC1: 5A - 250VAC.
Clamping terminals (for cross-section cable up to 6mm), with
unlosable screws.

/ TemControl / 4

1 NO + 1 NC

Selection guide
TemControl
Contactors

CNR Contactors
Reference

Contacts

CNR2510
CNR3210
CNR2520
CNR3220

1 NO
1 NO
2 NO
2 NO

Pack: 1 unit

In
(A)
25A
32A
25A
32A

No. of
modules

250V~
250V~
250V~
250V~

1
1
1
1

For remote switching of circuits up to 32A.


1-pole and 2-pole 25A & 32A silent contactors.
Contacts: NO (25A & 32A).

1 NO

2 NO

CNCP - 1/2 module Spacer


To be placed on both side of a DIN-rail device to avoid
overheating which may occur when ambient temperature is over
30C or when several devices are side by side on the same rail.
Main features
Double-rectified coil which ensures full silent operation and
increased electrical life.
Front indicator showing actual position of the contacts.
Sealable clamping terminals, with unlosable screws.
Maximum cable cross-section: 10mm
Switching capacity AC1: 25A & 32A - 250/400VAC
Command voltages: 230/240VAC.
Electrical life: over 400.000 operations.
In accordance with CE and EN 60947-4-1.

BC Main contact blocks for CNR Contactors


Reference
BC2520
BC3220

Contacts

In
(A)

No. of
modules

2 NO
2 NO

25A - 400V~
32A - 400V~

1
1

2 NO

Pack: 1 unit

2 pole 25A & 32A device. To be clipped on the left side of the
contactor, without need of any screw or additional wiring.

BA Auxiliary contact blocks


Reference
BA0510
BA0520

Contacts

In
(A)

No. of
modules

1 changeover
1NO+1NC

5A - 250V~
5A - 250V~

1/2
1/2

1 CO

Pack: 1 unit

When added to a device, BA blocks make additional auxiliary


contacts available for a remote signal, or to synchronously control
other devices.
The same blocks may be used with TR impulse switches and
CNR - CNO contactors series.
Up to 2 blocks may be added to a single device, and when a
main contact block is already fitted, only 1 auxiliary contact block
can be added.
Blocks are clipped on the left side of an impulse switch or of a
main contact block, without need of any screw or additional wiring.
Switching capacity AC1: 5A - 250VAC.
Clamping terminals (for cross-section cable up to 6mm), with
unlosable screws.

/ TemControl / 5

1 NO + 1 NC

Selection guide
TemControl
Contactors

CNO Contactors
Reference

Contacts

In
(A)

No. of
modules

CNO2520
CNO3220

2 NO
2 NO

25A - 250V~
32A - 250V~

1
1

2 NO

Pack: 1 unit

Contactors with a tool-manageable 3-position front handle which


allows override, on and off switching of the device.
Front switch positions, NO contacts :
Stop - Contacts permanently open
AUTO - Normal operation
Perm. - Contacts permanently closed
CNCP - 1/2 module Spacer
To be placed on both side of a DIN-rail device to avoid
overheating which may occur when ambient temperature is over
30C or when several devices are side by side on the same rail.
Main features
Double-rectified coil which ensures full silent operation and
increased electrical life.
3-position front handle, tool-manageable.
Front indicator showing actual position of the contacts.
Maximum cable cross-section: 10mm
Switching capacity AC1: 25A & 32A - 250/400VAC
Command voltage: 230/240VAC.
In accordance with CE and EN 60947-4-1.

BC Main contact blocks for CNO Contactors


Reference
BC2520
BC3220

Contacts

In
(A)

No. of
modules

2 NO
2 NO

25A - 400V~
32A - 400V~

1
1

2 NO

Pack: 1 unit

2 pole 25A & 32A device. To be clipped on the left side of the
contactor, without need of any screw or additional wiring.

BA Auxiliary contact blocks


Reference
BA0510
BA0520

Contacts

In
(A)

No. of
modules

1 changeover
1NO+1NC

5A - 250V~
5A - 250V~

1/2
1/2

1 CO

Pack: 1 unit

When added to a device, BA blocks make additional auxiliary


contacts available for a remote signal, or to synchronously control
other devices.
The same blocks may be used with TR impulse switches and
CNR - CNO contactors series.
Up to 2 blocks may be added to a single device, and when a
main contact block is already fitted, only 1 auxiliary contact block
can be added.
Blocks are clipped on the left side of an impulse switch or of a
main contact block, without need of any screw or additional
wiring.
Switching capacity AC1: 5A - 250VAC.
Clamping terminals (for cross-section cable up to 6mm), with
unlosable screws.

/ TemControl / 6

1 NO + 1 NC

Selection guide
TemControl
Contactors

CNI 4 pole Contactors


Reference
CNI2540
CNI4040
CNI6340

Pack: 1 unit

Contacts

In
(A)

No. of
modules

4 NO
4 NO
4 NO

25A - 400V~
40A - 400V~
63A - 400V~

2
3
3

4 NO

4-pole contactors with 25A to 63A switching capacity, to be used


mainly for industrial applications.
Main contacts 4NO.
CNCP - 1/2 module Spacer
To be placed on both side of a DIN-rail device to avoid
overheating which may occur when ambient temperature is over
30C or when several devices are side by side on the same rail.
Main features
Switching capacity AC1: 25A, 40A & 63A - 250/400VAC.
Command voltage : 220/240V 50Hz.
Front indicator showing actual position of the contacts.
Maximum cable cross-section: 10mm (25A) and 25mm (40A and
63A).
Electrical life over 150.000 operations.
In accordance with CE and EN 60947-4-1.

BI Auxiliary contact blocks


Reference

Contacts

In
(A)

No. of
modules

1NO+1NC

6A - 400V~

1/2

1 NO + 1 NC

BI0620
Pack: 1 unit

An auxiliary contact side-block may be clipped on the right side of


each CNI contactor.
Standard auxiliary contacts: 1NO+1NC, 6A (AC1).

/ TemControl / 7

Selection guide
TemControl
Time switches and Digital programmer

Time switches
Reference
TSDR - daily
TSSR - weekly

Reserve

Un

No. of
modules

100h
100h

230V~
230V~

3
3

Pack: 1 unit

Electromechanical time switches with daily or weekly programs.


Daily program : 48 switching positions with a minimum interval of
30m.
Weekly program: 48 switching positions with a minimum interval of
2 hrs.
Main features
Quick programming by captive switching segments.
Easy reading of the switching positions.
Types with 100-hour running reserve available.
Quartz motor.
Actual time indicator.
Direct change of the time hour
3-position switch-handle: permanent ON/Automatic/permanent OFF
Sealable transparent front cover.
Tunnel type terminals (cable cross-section: 6mm)
Contact: 1 changeover 16A - 250VAC
Command voltage: 230VAC
Dimensions (mm): A - 55, B - 55, C - 44, D - 60, E - 105

Digital programmer
Reference
TSSE
Pack: 1 unit

Channels

Un

No. of
modules

230V~

Electronic 1-channel programmer, with digital display.


Weekly program.
40 memory spaces.
Block programming of days (increases the available switching
capacity and makes the programming easier).
Main features
Easy programming.
Large display for better reading.
100-hour running reserve.
Pulse generator (duration: 1 sec.).
Minimum switching interval: 1m.
Override ON or OFF position
Permanent ON or OFF position.
Sealable transparent front cover.
Clamping terminals (cable cross-section: 6mm).
Contact: 2 changeover 16A - 250VAC
Command voltage: 230VAC
Dimensions (mm):
A - 55, B - 55, C - 38, D - 60, E - 90

/ TemControl / 8

Technical information
TemControl
Impulse switches

16A
1-2P

32A
1-2P

:Control voltage range (in % of Un)


Alternative current (AC)
coil power loss
pick up power
Direct current (DC)

90-110%
11VA
14,5VA
7,5W

90-110%
11,5VA
16,5VA
8W

Maximum coil holding voltage time (2)

unlimited

unlimited

Impulse times
Minimum impulse time (under Un)
Minimum impulse time (90% Un)
Minimum time between impulses
Maximum number of impulses per min.

0,050s
0,100s
0,150s
250

0,050s
0,100s
0,150s
250

Lifetime (in number of operations) (3)


Electrical (in AC-1 - at full load)
Mechanical

4 x 105
2 x 106

3 x 105
2 x 106

20A
16A
2W
20A

32A
16A
2W
32A

Specifications
Coil

(1)

Load specifications
Maximum load AC-1 per phase
Maximum load DC (30VDC)
Maximum load per phase (under 5V)
Short circuit fuse protection
Control voltage: 230VAC/115VDC.
Whenever the normal use of the impulse switch integrates a permanent coil
working, use a CNCP spacer on both sides and make sure that the duty factor
allows the device to come back to the ambient temperature.
(3) 1 cycle = 2 operations per pole (closing + opening).
(1)
(2)

Combination table
TR impulse switch

BA auxiliary contact blocks

2 Pole

2 Pole

Total
No. of poles

Total 17,5mm

1Pole

TR + BT

(max)

1
1
-

1
1

1
1

1
2
3
4

1
1
2
2

2
2
1
1

BT main contact blocks

Contact and auxiliary blocks are clipped on the left side of the impulse switch in the following order,
starting from the impulse switch + main contact block + auxiliary contact block.

Dimensions (mm)

Reference

Width DIN module (17,6mm)

TR1610
TR3210
TR1611
TR1620
TR3220

58
58
58
58
58

62
62
62
62
62

43,5
43,5
43,5
43,5
43,5

65
65
65
65
65

85
85
85
85
85

1
1
1
1
1

BT1620
BT3220

58
58

58 43,5 65 85
58 43,5 65 85

1
1

BA0510
BA0520

58
58

58 43,5 65 85
58 43,5 65 85

1/2
1/2

/ TemControl / 9

Technical information
TemControl
Contactors

CNR & CNO contactors

25A
1-2P

32A
1-2P

Coil : Control voltage range (in % of Un) (1)


Alternative current (AC)
coil power loss
pick up power

85-110%

85-110%

4VA
4VA

4,5VA
4,5VA

Maximum coil holding voltage time (2)

unlimited

unlimited

4 x 105
2 x 107

3 x 105
2 x 107

Contact bounce time at closing

< 0,007s

< 0,007s

Operate and release time (bounce time incl.)


Pick-up time
NO contact
Drop-out time
NO contact

< 0,035s
< 0,040s

< 0,035s
< 0,040s

60A
90A

60A
90A

90A
75A

90A
75A

4,5kW - 250VAC
13,5kW - 400VAC
2,5kW - 250VAC
1,1kW - 250VAC
2,2kW-250VAC/4-400AC
2W
25A

7,5kW - 250VAC
22kW - 400VAC
2,5kW - 250VAC
1,1kW - 250VAC
2,2kW-250VAC/4-400AC
2W
32A

Specifications

Lifetime (in number of operations) (3)


Electrical (in AC-1 - at full load)
Mechanical

Maximum peak current at closing (I eff)


Single phase 250V~ cosj=0,95
3-phase 250V~ cosj=0,65
Maximum peak current at opening (I eff)
Single phase 250V~ cosj=0,95
3-phase 250V~ cosj=0,65
Load specifications per phase
Maximum load AC-1

Contactor
Contactor + main contact block

Maximum load AC-5b


Maximum load AC-7b
Maximum load AC-3
Maximum load per phase (under 5V)
Short circuit fuse protection (gL)
(1)
(2)
(3)

Control voltage: 230/240VAC.


When ambient temperature is over 30o or when several contactors are side-to-side on the same rail, use a CNCP spacer on both sides of each device.
1 cycle = 2 operations per pole (closing + opening).

Combination table
CNR/CNO contactor BC main contact blocks
1Pole

2 Pole

2 Pole

1
1
-

1
1

1
1

Total 17,5mm BA auxiliary contact blocks


Total
No. of poles CNR/ CNO + BC
(max)
1
1
2
2

1
2
3
4

2
2
1
1

Contact and auxiliary blocks are clipped on the left side of the contactor in the following order, starting
from the contactor + main contact block + auxiliary contact block.
Dimensions (mm)

Reference

Width DIN module (17,6mm)

CNR2510
CNR3210
CNR2520
CNR3220
CNO2520
CNO3220

58
58
58
58
58
58

62
62
62
62
62
62

43,5
43,5
43,5
43,5
43,5
43,5

65
65
65
65
65
65

85
85
85
85
85
85

1
1
1
1
1
1

BT1620
BT3220

58
58

58 43,5 65 85
58 43,5 65 85

1
1

BA0510
BA0520

58
58

58 43,5 65 85
58 43,5 65 85

1/2
1/2

/ TemControl / 10

Technical information
TemControl
Contactors

CNI contactors

63A
4P

220/240V-50Hz 220/240V-50Hz 220/240V-50Hz


85-110%
85-110%
85-110%
7VA
7VA
4,4-8,4VA
33-45VA
33-45VA
14-18VA

Coil : Control voltage


Control voltage range Un
Power consumption (AC)

coil power loss


pick up power
Short circuit fuse protection (gL)
Lifetime (in number of operations) (1)
Electrical (at full load)
AC-1
AC-3

35A

63A

80A

10 5
1,5 x 107

10 5
1,5 x 107

10 5
1,5 x 107

10 5

10 5

10 5

25A
9A
2,5kW
4kW
2W

40A
27A
8kW
12,5kW
3W

63A
27A
8kW
12,5kW
7W

Mechanical
Maximum load per pole
Maximum load AC-1
Maximum load AC-3 - Rated operational current
Maximum load AC-3 - 3-phase motor
230/240V
380/415V
Power loss per pole at AC-1
(1)

40A
4P

25A
4P

Specifications

1 cycle = 2 operations per pole (closing + opening).

Combination table
Total
No. of poles

BA auxiliary contact blocks

Total 17,5mm

4Pole

(max)

CNI + BI

2 or 3+1/2

CNI contactor

Auxiliary block is clipped on the left side of the contactor.

Dimensions (mm)

Reference

CNI2540
CNI4040
CNI6340

60
60
60

60 43,5 65 85
60 43,5 65 85
60 43,5 65 85

2
3
3

BI0620

58

58 43,5 65 85

1/2

/ TemControl / 11

Width DIN module (17,6mm)

Selection guide
TemControl
Staircase lighting time switch and Bell+buzzer+transformer

TMP Staircase lighting time switch

Reference
TMP16

In (A)
Voltage

Incandescent
lamps

No. of
modules

16A - 230V~

2300W

Pack: 1 unit

Stair lighting time switch allows the timed management of


lights in: halls, corridors and stairs.
This component offers a double operating mode: permanent
light or timed light with a switch OFF time adjustable from 20
seconds up to 10 minutes with recycling option.
Main features
Rated voltage: 230 V~
Frequency: 50-60Hz
DIN modules: 1
Max. cable capacity: 4mm2
Type of contacts: 1NO (not potential-free)
Contact capacity: 16A, cosj=1
Number of cycles: 40.000
Timing adjustment: 20s. to 10min.

Dimensions (mm)

27

40

20
s

89

45

10
min

18

59

TMB Bell+buzzer+transformer

Reference

Power
supply

No. of
modules

TMB230N

230V~

Pack: 1 unit

Bell/buzzer is used for audible signalling, in the domestic and


commercial installations.
This component is provided with a double insulated envelope
and a transformer complying with the EN 60742 standards,
which can be classified as a transformer for bells. This
means it is conceived to power supply bells or similar warning
intermittent operating devices.
Dimensions (mm)

Main features
Primary voltage: 230V~
Secondary voltage: 12V~
Frequency: 50-60Hz
DIN rail modules: 2
Max. cable capacity: 4mm2

87

45

26

44

230V

59

35

/ TemControl / 12

Selection guide
TemControl
Safety transformers

TRF Safety transformers

Reference

Primary
Voltage

Secondary
Voltage

Power
consumption

No. of
modules

TRF10S
TRF15S
TRF10N
TRF15N
TRF30N
TRF40N

230V~
230V~
230V~
230V~
230V~
230V~

12V~
12V~
12/24V~
12/24V~
12/24V~
12/24V~

10VA
15VA
10VA
15VA
30VA
40VA

2
2
2
2
4
4

Pack: 1 unit

End suffix: S = Failure proof

N = Resistant to short-circuit

Safety transformers are used for distributing very low voltage; this guarantees
high protection against electrocution.
The short-circuit resistant and the failure proof transformers offer great reliability
in terms of the galvanic separation between the primary and secondary circuits.
Operating conformity is also guaranteed thanks to their short-circuit protection.
Main features
DIN modules: 2 and 4
Max. cable capacity: 4mm2
Protection degree: IP20
Double insulated
In transformers resistant to short-circuit not by construction, the over-temperature
consequent on a short-circuit or an overload does not exceed determinate set
limits: when normal conditions are returned, performance returns to within the
levels established by the standard and the transformer functions correctly.
These devices are defended from short-circuits by their incorporated protection
device.
Failure proof transformers, on the other hand can no longer function following
anomalous use or fault, even though they do not represent any danger to the
user or the adjacent parts.
Note: Rated power = intermitent service.
Rated power reduced approx. a 35% = continuous service.

Dimensions (mm)

1
PRI.

SEC.
3

70

/ TemControl / 13

Selection guide
TemControl
Manual motor starters

Manual motor starters

Rated current

Overload relay
setting range

0,16A
0,25A
0,4A
0,63A
1A
1,6A
2,5A
4A
6,3A
10A
16A
20A
25A

0,1-0,16A
0,16-0,25A
0,25-0,4A
0,4-0,63A
0,63-1A
1-1,6A
1,6-2,5A
2,5-4A
4-6,3A
6,3-10A
10-16A
16-20A
20-25A

Reference
TMS25-0,16
TMS25-0,25
TMS25-0,4
TMS25-0,63
TMS25-1
TMS25-1,6
TMS25-2,5
TMS25-4
TMS25-6,3
TMS25-10
TMS25-16
TMS25-20
TMS25-25

Pack: 1 unit.
Accessories for manual motor starters TMS
Auxiliary contacts
Types

Reference

1NO+1NC
2NO
1NO early make+1NC
2NC
Pack: 1 unit.

PS11
PS20
PS10
PS01

No. of DIN modules


0,5
Rated voltage
500V
Ith
6A
AC15
3,5A 230V, 2A 400V, 1A 500V
Terminal capacity
0,752,5mm2 (1 or 2 conductors)
Undervoltage trip and Shunt trip
Undervoltage trip
Rated frecuency:
Trip range:
Operating range:

Reference
50-60Hz
(0,350,7)Ue
(0,851,1)Ue

Shunt trip

U (1)

Reference

Rated frecuency:
Trip range:
Operating range:

50-60Hz
(0,71,1)Ue

A (1)

Pack: 1 unit.
(1) Indicate rated voltage and frequency.
Available rated voltages: 24, 110, 230, 400V AC

/ TemControl / 14

TMS25 width
corresponds to 2,5 DIN
modules (DIN 43880).
3 pole configurations
as per IEC 947-4-1.
Category AC3.
FIELD FITTABLE SERIES

Selection guide
TemControl
Enclosures and mounting accessories for manual motor starters

Enclosures for manual motor starters

Surface enclosure

Reference

IP-41 Top and bottom entries

O 41

IP-55 Possibility of fitting auxiliary


contacts
Pack: 1 unit.

O 55

Flush fitting enclosure

Reference

IP-41

CP 41

IP-55
Possibility of fitting auxiliary
contacts
Pack: 1 unit.

CP 55

Enclosure mounting accessories

Padlocking

Prevents from closing operation. Max. 3


padlocks

Reference
Z

Pack: 1 unit.

Emergency stop push-button


Turn unlatch
Red push button 35mm
IP55 protection supplied

Pack: 1 unit.

/ TemControl / 15

Reference

NAT

Technical information
TemControl
Manual motor starters

Protection against overloads and short-circuits


Main application field: control (start-up, protection
and switch-off) of motors with power up to 11kW
or other consumptions up to 25A.
In accordance with Standars
IEC 947, EN 60947, SEV, EZU, VDE 0660

Terminal capacity
0,75-4,0 mm2

Rated operating current


25A, setting range from 0,1 to 25A.

Terminal torque
1,2Nm for main contacts
1,0Nm for auxiliary contacts

Mounting
DIN rail 35mm.

Electrical and mechanical endurance


100.000 operacions

Dimensions
As per DIN 43880. Width 45mm.

Max. cycle rate


30 opearations/hour

Rated voltage
690V

Max. peak voltage


6.000V

Rated frequency
50-60Hz

Impact resistance
15g (impact time 10ms)

Magnetic trip current


Factory set at 12In.
Phase failure sensitivity
As per DIN VDE 0660 part 102, IEC 947-4-1.
Operating temperature
Between -25oC and 55oC, with free air circulation.
Between -25oC and 40oC, closed panel mounting.

Breaking capacity

Back-up-fuse for Icc Icu


Icu [kA]

Fuse (gL, aM) [A]

Max. current
setting

230V

400V

0,16A - 1,6A
2,5A - 6,3A
10A
16 - 25A

100
100
100
10

100
100
6
6

500V 690V
100
3
3
2,5

100
2,5
2,5
2

Rated operational
current
0,16A
0,25A
0,4A
0,63A
1A
1,6A
2,5A
4A
6,3A
10A
16A
20A
25A

/ TemControl / 16

230V

400V

500V 690V

No additional
protection
required

80A
80A
80A

80A
80A
80A
80A

25A
35A
50A
50A
63A
63A
63A

20A
25A
35A
35A
35A
50A
50A

Tripping characteristics and Dimensions


TemControl
Manual motor starters

60

min.

40

sec.

m i nmin.
utos

20
10
8
6
4
2
1
40

milisec.

s e gsec.
undos

20
10
8
6
4
2
1
1 1.2
1.05

x In

6 7 8 9 10

15

20

x In

Mltiplos de In
Sin proteccin magntica

With magnetic protection

Without magnetic protection

Manual motor starters TMS. Dimensions (mm)

Auxiliary contacts. Dimensions (mm)

83

38

80

45

45

80

22.5

38

45

8.8

72

72

Surface enclosures. Dimensions (mm)

Flush fitting enclosures. Dimensions (mm)

94
32

96

75

96

80

/ TemControl / 17

103.5

130

150.5

15

85

Selection guide
TemControl
TemSwitch Isolating switches
TDS series

Reference

TDS I 32
TDS I 63
TDS I 100

TDS II 32
TDS II 63
TDS II 100

TDS III 32
TDS III 63
TDS III 100

TDS IIII 32
TDS IIII 63
TDS IIII 100

No. of
poles

No. of DIN
modules

Operating current
(AC22)

Units per
pack

32A
63A
80A
100A
(AC21)

12

32A
63A
80A
100A
(AC21)

32A
63A
80A
100A
(AC21)

32A
63A
80A
100A
(AC21)

Dimensions

/ TemControl / 18

Rated voltage:
240V/415V~
Frequency:
50/60Hz
Terminal capacity:
1 to 35mm2
Mounting:
35mm symmetrical DIN rail
(EN 50022-DIN 46277)
Positive contact indication.

Technical information
TemControl
TemSwitch Isolating switches
TDS series

Standards
In accordance with Standards: UNE EN 60947-1 and UNE EN 60947-3.

Features

Nomenclature

Degree of protection
No. of poles
Frequency
Operating voltage
Isolating voltage
Withstand current at impulse
Operating current
Uninterrupted current
Rated thermal current
Rated thermal current (insulation)
Duty
Making capacity
Breaking capacity
Short delay current
Short-circuit making capacity
Short-circuit current with
preinstantaneous protection
Duty
Auxiliary contact
Shunt trip
Electrical operations
Mechanical operations

Ue
Ui
Uimp
Ie
Iu
Ith
Ithe

Icw
Icm
Fuse
TDC 63A

TDS 32A

TDS 63A

TDS 100A

IP 2LX
I, II, III, IIII
50-60Hz~
240/415V~
660V~
4kV
32A
63A
80A
50A
uninterrupted
3 Ie
3 Ie
20Ie (5sec.)
23Ie (3sec.)
40Ie (1sec.)
53Ie (0,5sec.)
59Ie (0,3sec.)
700A
6000A (gl 63A)

IP 2LX
I, II, III, IIII
50-60Hz~
240/415V~
660V~
4kV
63A
63A
80A
70A
uninterrupted
3 Ie
3 Ie
10Ie (5sec.)
12Ie (3sec.)
20Ie (1sec.)
27Ie (0,5sec.)
30Ie (0,3sec.)
700A
6000A (gl 63A)

3000A
AC-22A

3000A
AC-22A

IP 2LX
I, II, III, IIII
50-60Hz~
240/415V~
660V~
4kV
80A
100A
115A
100A
uninterrupted
3 Ie
3 Ie
12.5Ie (5sec.)
13.7Ie (3sec.)
20Ie (1sec.)
21.6Ie (0,5sec.)
23.7Ie (0,3sec.)
700A
4500A (80A gF)
3000A (100A gL)

TDA *
SHT *

TDA *
SHT *

30.000
40.000

* Field fittable series.


Refer to page TemDin 10

Ambient temperature
From -5oC to 40oC.
Altitude
Up to 2.000 metres.
Recommended torque
From 1,7 to 2.5Nm.
Max.: 2,5Nm (25Kgf cm).
Min: 1,7Nm (17Kgf cm).

/ TemControl / 19

80A AC-22A
100A AC-21A
TDA *
SHT *