Vous êtes sur la page 1sur 1

DCM / EDCM

DOCSIS / EURODOCSIS Communication Module

MONITORED PARAMETERS
BETA PRO 60 G

HARGON 2710
HARGON 2730

HARGON 2610
HARGON 2630

rd / wrt

Using standard HMS MIBs

rd / wrt

rd / wrt

A/B switch

+/+

Power RxA/RxB

+/-

Transmited optical power Tx1/Tx2

+/-

Optical transmitter laser current Tx1/Tx2

+/-

Ingress Switch 1, 2

+/+

+/+

+/+

Internal powering DC

+/-

+/-

+/-

Remote powering AC

+/-

+/-

+/-

Temperature

+/-

+/-

+/-

Tamper

+/-

+/-

+/-

Rx transponder level

+/-

+/-

+/-

Tx transponder level

+/-

+/-

+/-

Forward attenuators

+/+

+/+

+/+

Forward equalizers

+/+

+/+

+/+

Reverse attenuators

+/+

+/+

+/+

Reverse equalizers

+/+

+/+

+/+

Reverse conguration

+/+

Using proprietary MIBs


Easy implementation in DOCSIS / EuroDOCSIS environment
Embedded WWW page
Remote access monitoring via WWW page and/or
monitoring software
SNMP v1, v2c compliant
Cost effective solution thanks to using existing HFC
infrastructure
Remote node or ampli er rmware upgrade

NETWORK COMMUNICATION
Network protocols

IP, UDP, TCP, DHCP, TFTP

SNMP

v1, v2c

Embedded web interface

Read Access MIB variables,


Read-Write Access parameters

Monitoring module DCM / EDCM is an outstanding solution


for HFC network management and monitoring. Thanks
to build-in DOCSIS / EuroDOCSIS modem, it simplies
implementation of management system for optical nodes
and broadband ampliers. The solution uses existing
DOCSIS/EuroDOCSIS environment and equipment, driving
signicantly down costs of Network Management System
implementation.

DCM / EDCM CARD SPECIFICATION


Standards

DOCSIS 2.0, EuroDOCSIS 2.0

Tx frequency range

5 to 42 MHz DOCSIS
5 to 65 MHz EuroDOCSIS

Channel bandwidth

6 MHz DOCSIS
8 MHz EuroDOCSIS

Received center frequency range

91 to 857 MHz DOCSIS


108 to 862 MHz EuroDOCSIS

Power consumption

<5W

DCM/EDCM module enables optical node management


and monitoring using web browser, no proprietary software
required and access to nodes web page is free. Through a
Simple Network Management Protocol (SNMP) interface,
standard MIBs are used for efcient network monitoring
and management. SNMP standard enables cooperation
with new VECTOR Craft Management Software (CMS) and
additionally with open monitoring systems (e.g. Omni2000)
using access to MIB base.

ORDERING SYSTEM
BETA PRO 60 G

HARGON 2710
HARGON 2730

HARGON 2610
HARGON 2630

Monitoring module

Monitoring kit

Monitoring kit

MONITORING
SOFTWARE

HFC
HEC

DCM/EDCM module enables remote upgrading of the node


or amplier rmware.

OPTICAL NODE
WITH HMS
TRANSPONDER

CMTS

SNMP / IP

Congurable parameters, such as signal levels and slope,


AGC or redundancy and segmentation, can be adjusted
remotely through the module, without interruption in signal
transmission.

RF
MANAGEMENT

OPTICAL NODE
WITH HMS
TRANSPONDER

UNINTERRUPTIBLE
POWER SUPPLY

OPTICAL NODE
WITH HMS
TRANSPONDER

Unless otherwise specied, all specications are testedat room


temperature 25C
23/03/2016 Specications are subject to change without notice.