Académique Documents
Professionnel Documents
Culture Documents
3045CLR
USER GUIDE
u-line.com
Contents
Intro
Maintenance
Cleaning
Safety
Safety and Warning
Cleaning Condenser
Extended Non-Use
Installation
Service
Environmental Requirements
Troubleshooting
Electrical
Warranty
Cutout Dimensions
Product Dimensions
Side by Side Installation
Water Hookup
Drain
Drain Pump
Anti-Tip Bracket
General Installation
Integrated Panel Dimensions
Integrated Grille / Plinth Dimensions
Integrated Panel Installation
Grille / Plinth Installation
Door Swing
Door Stop
Door Adjust
Operating Instructions
First Use
Control Operation
Ice
Sabbath Mode
Airflow and Product Loading
USER GUIDE
u-line.com
WELCOME TO U-LINE
Congratulations on your U-Line purchase. Your product comes from a company with over five decades and three generations
of premium modular ice making, refrigeration, and wine preservation experience. U-Line continues to be the American
leader, delivering versatility and flexibility for multiple applications including residential, light commercial, outdoor and marine
use. U-Lines complete global product collection includes modular Wine Cellars, Drinks Cabinets, Clear Ice Machines, Glass &
Solid Door Refrigerators, Drawer Models, and Freezers.
U-Line has captivated those with an appreciation for the finer things with exceptional functionality, style, inspired innovations
and attention to even the smallest details. We are known and respected for our unwavering dedication to product design,
quality and selection. U-Line is headquartered in Milwaukee, Wisconsin with a west coast office located in Laguna Beach,
California and European support in Dublin, Ireland. U-Line has shipped product to five continents for over two decades and is
proud to have the opportunity to ship to you.
PRODUCT INFORMATION
Looking for additional information on your product? User Guides, Quick Reference Guides, CAD Drawings, Compliance
Documentation, and Product Warranty information are all available for reference and download at u-line.com under
Documentation.
SERVICE INFORMATION
Answers to Customer Frequently Asked Questions are available at u-line.com under Customer Care or you may contact our
Customer Care group directly, contact information below.
GENERAL INQUIRIES
U-Line Corporation
T: +1.800.779.2547
F: +1.414.354.5696
T: +1.414.354.0300
F: +1.414.354.7905
Email: sales@u-line.com
u-line.com
CONNECT WITH US
Designed, engineered and assembled in WI, USA
Introduction 1
USER GUIDE
u-line.com
NOTICE
PLEASE READ all instructions before installing,
operating, or servicing the appliance.
! DANGER
Do not use electrical appliances inside the food
storage compartment of this appliance.
! WARNING
! DANGER
Danger means that failure to follow this safety
statement will result in severe personal injury or
death.
! WARNING
! WARNING
Warning means that failure to follow this safety
statement could result in serious personal injury
or death.
! WARNING
! CAUTION
Caution means that failure to follow this safety
GENERAL PRECAUTIONS
Use this appliance for its intended purpose only and follow
these general precautions with those listed throughout this
guide.
! WARNING
To avoid a hazard due to instability of the
appliance, it must be fixed in accordance with
the instructions.
USER GUIDE
u-line.com
! CAUTION
Use care when moving and handling the unit.
Use gloves to prevent personal injury from sharp
edges.
NOTICE
Do not lift unit by door handle.
USER GUIDE
u-line.com
! DANGER
RISK OF CHILD ENTRAPMENT. Before you throw
away your old refrigerator or freezer, take off
the doors and leave shelves in place so children
may not easily climb inside.
USER GUIDE
u-line.com
Environmental Requirements
This model is intended for indoor/interior applications only
and is not to be used in installations that are open/
exposed to natural elements.
! CAUTION
Damages caused by ambient temperatures of
40F (4C) or below are not covered by the
warranty.
Environmental Requirements 1
USER GUIDE
u-line.com
Electrical
! WARNING
NOTICE
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle
adapter.
location.
Electrical 1
USER GUIDE
u-line.com
Cutout Dimensions
CUTOUT DIMENSIONS
PREPARE SITE
Your U-Line product has been designed exclusively for a
built-in installation. When built-in, your unit does not
Preferred location
for drain, water
line and receptacle
is in adjacent
5/8"
cabinet.
(16 mm)
33-7/8"
(860 mm)
to
34-7/8"
(886 mm)
24"
(610 mm)
17-3/4"
(450 mm)
! CAUTION
Unit can NOT be installed behind a closed cabinet
door.
Cutout Dimensions 1
USER GUIDE
u-line.com
Product Dimensions
33-11/16" to 34-11/16"
(856 mm to 881 mm)
3-5/8" to 4-5/8"
(92 mm to 118 mm)
17-3/4"
(450 mm)
Product Dimensions 1
USER GUIDE
u-line.com
Side-by-Side Installation
OTHER SITE REQUIREMENTS
Side-by-Side Installation
1/4" (6 mm)
Side-by-Side Installation 1
USER GUIDE
u-line.com
Water Hookup
PREPARE PLUMBING
! CAUTION
home.
! WARNING
Prior to installation, determine if this product
contains a gravity style drain or factory installed
drain pump. Products without a drain pump may
only use a gravity style drain. Failure to connect
! CAUTION
Turn off water supply and disconnect electrical
supply to unit prior to installation.
! WARNING
Connect to potable water supply only.
! CAUTION
Review, obey, and understand the local
plumbing codes before you install your unit.
Connect to the cold water supply. The water
pressure should be between 20 and 120 psi (138
and 827 kPa). The water line MUST have a shutoff valve on the supply line.
Water Hookup 1
USER GUIDE
u-line.com
3. Locate water
valve in the front
of the unit and
thread water
supply line
through.
NOTICE
Route the water
supply line
through the unit so it does not come into contact
with any internal components other than the
solenoid valve. Normal operation creates some
vibration. A water supply line contacting an
internal component or cabinet wall can cause
excessive noise during operation or damage to
the line.
Remove
ZLWKDW
screwdriver
Water Hookup 2
USER GUIDE
u-line.com
Drain
GRAVITY DRAIN
Normal
Proper Drain
With Trap
Poor Drainage, Water Will Back Up
DRAIN CONNECTION
! CAUTION
Drain line does not create traps and is vented per local
code.
! CAUTION
Drain 1
USER GUIDE
u-line.com
Y-Branch Tailpiece
P60 Pump Required
Air Gap
(Optional Hook-Up)
Waste
If you need to install a P60 drain pump into your unit, see
6KXW2
Valve
Hot
Water
Cold
Water
NOTICE
Stand Pipe
P60 Pump Required
Hot
Water
Cold
Water
Waste
Disposal Assembly
P60 Pump Required
Air Gap
(Optional Hook-Up)
Waste
Hot
Water
Cold
Water
6KXW2
Valve
Drain 2
USER GUIDE
u-line.com
Drain Pump
NOTICE
PLEASE READ this instruction completely before
attempting to install or operate the unit.
Improper hook-up can result in substantial
property damage! If you are unsure of your
ability to safely connect the drain pump to the
INCLUDED IN KIT:
1. 1x S-shaped Drain Tube
3. 1x Vent Tube
Clamp
8. 1x P60 Pump
Modification of the P60-20 drain pump will void all
warranties.
9. 1x Discharge Tub
(Used on older models only)
NOTICE
Keep your proof of purchase for warranty
purposes.
TOOLS REQUIRED:
1/4" x 6" Blade Screwdriver
Adjustable Pliers
Drain Pump 1
USER GUIDE
u-line.com
Wiring Plug
Ground Terminal
Discharge Tube Connector
Drain Tube
INSTALLATION PROCEDURE
! WARNING
Vent Tube
Discharge Tube
Jumper
Block
! CAUTION
Pump Wiring
Plug
! CAUTION
When working with tools inside of unit, be
careful so as not to nick or damage any
refrigerant lines/pipes or wires.
Drain Pump 2
USER GUIDE
u-line.com
! WARNING
! CAUTION
Failure to properly secure the vent tube will
result in water damage to the unit and
surrounding areas. Do not allow vent tube to
kink, bend or be obstructed in any way.
! CAUTION
Vent tube must be straight and parallel to
insulated tubes. Do not over-tighten the plastic
tie wraps. Over-tightening can pinch vent tube
closed or cut into insulation.
Drain Pump 3
USER GUIDE
u-line.com
Anti-Tip Bracket
SIDE MOUNT
Left Hinged Cabinet
! CAUTION
The anti-tip bracket must be installed to prevent
the unit from tipping when doors are fully
opened or excess weight is placed on the front of
the unit.
TOP MOUNT
Side mount position is used when you are unable to mount
the bracket to the underside of your countertop.
surrounding cabinetry.
surrounding cabinetry.
5. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8"
3. Using a 3/32" (2.50 mm) drill bit, drill 3 pilot holes 5/8"
(16 mm) deep into bottom of counter top. Use the
Anti-Tip Bracket 1
USER GUIDE
u-line.com
General Installation
INSTALLATION
edge as shown.
3. Re-check the leveling, from front to back and side to
side. Make any necessary adjustments. The units top
the countertop.
necessary. Use
included tool to adjust the height of the rear legs.
INSTALLATION TIP
If the room floor is higher than the floor in the cutout
opening, adjust the rear legs to achieve a total unit rear
height of 1/8" (3 mm) less than the openings rear height.
Shorten the unit height in the front by adjusting the front
legs. This allows the unit to be gently tipped into the
opening. Adjust the front legs to level the unit after it is
correctly positioned in the opening.
General Installation 1
USER GUIDE
u-line.com
INTEGRATED PANEL
NOTICE
Due to differences in surrounding cabinetry the
panel may not perfectly align with door. The
(20 mm)
17-1/2"
(445 mm)
Panel Preparation
A full integrated door panel completely covers the door
frame and provides a built-in appearance.
30"
(762 mm)
NOTICE
The door panel must not weigh more than 20 lbs
(10 kg).
Integrated Panel
NOTICE
When applying an integrated panel to a unit,
ensure that both sides are finished in order to
prevent warping. In some panel installations,
the panel may be visible through the glass while
the door is open.
USER GUIDE
u-line.com
Wooden Insert
Top Design
and Insert Notch
Main Panel
NOTICE
The integrated panel aligns with the surrounding
cabinetry and, due to differences in cabinetry,
may not align perfectly with the door.
Integrated Panel
The appliance will need up to 34-1/2" (876 mm)
to the underside of the counter to leave room for
leveling adjustments.
NOTICE
If finishing panel or wooden insert, all sides
USER GUIDE
u-line.com
R 5/8"
(R 16 mm)
2-3/8"
(60 mm)
17-1/2"
(445 mm)
2-3/4"
70 mm
Insert Notch
2-3/4"
(70 mm)
Wooden Insert
Notch Depth: 1/8" (3 mm)
Top Detail
28-13/16"
(732 mm)
1/8" (3 mm)
3-1/2"
(89 mm)
USER GUIDE
u-line.com
Panel Preparation
An extended integrated panel can be used to maintain
alignment with an adjacent extended cabinet height or a
reduced toe-kick/grille application.
NOTICE
The door panel must not weigh more than 20 lbs
(10 kg).
USER GUIDE
u-line.com
Front
Side
Integrated Panel
U-Line
Unit
Cabinet
U-Line
Unit
> 3-5/16"
(> 89 mm)
Floor
Front
Side
U-Line
Unit
Cabinet
Integrated Panel
U-Line
Unit
Floor
USER GUIDE
u-line.com
(20 mm)
17-1/2"
(445 mm)
30"
to
33-7/8"
(762 mm
to
860 mm)*
Integrated Panel
* A minimum of 1" (25 mm) is required from the
floor to the bottom of the extended integrated
panel/frame for proper ventilation.
USER GUIDE
u-line.com
1-1/2"
(38 mm)
17-3/4"
(450 mm)
14-3/4"
(374 mm)
1-1/2"
(38 mm)
USER GUIDE
u-line.com
6. Secure integrated
panel to door using
Bar
Clamp
clamps. A robust
tape may also be
used. U-Line
recommends the
Door/Drawer
Wood
Panel
7. Using a 7/64"
(3 mm) drill bit, drill
Bar
Clamp
Align Panel
Against
Door Edge
First
guide.
NOTICE
It is important to ensure that all drilled holes are
drilled to the correct depth in order to avoid
splits in the wood when hardwood is installed.
NOTICE
Due to differences in floor construction or
surrounding cabinetry, the panel may not sit
Integrated Panel
Integrated Panel
USER GUIDE
u-line.com
NOTICE
If panel requires additional adjustment after
removing clamps, slightly loosen each screw and
adjust panel as necessary. Tighten screws upon
completion.
USER GUIDE
u-line.com
! WARNING
Disconnect electrical current to the unit before
removing the grille (plinth strip/base fascia).
When using the unit, the grille (plinth strip/base
fascia) must be installed.
Grille Mounting
Screws
Grille
Skirt
Grille Rail
USER GUIDE
u-line.com
Door Swing
For models that are installed adjacent to a wall, 1/4"
(6 mm) clearance is recommended from wall on hinge side
to allow the door to open 90. Allow for additional space
for any knobs or pulls installed on the integrated panel/
frame.
Wall
1/4" (6 mm)
90
Door Swing
Space Required
For any Knobs or Pulls
Door Swing 1
USER GUIDE
u-line.com
Door Stop
90; if the pin does not go into the hole shown, hold
pin.
NOTICE
If your unit is already undercounter, it will need
to be moved out to access the hinge. With the
90 stop pin in place, you will not be able to
replace the hinge cover.
NOTICE
The pin can be removed to return the door swing
back to its original 115 swing by tapping the pin
out from the bottom of the hinge.
CLOSER
hinge.
Door Stop 1
USER GUIDE
u-line.com
Door Adjustments
DOOR ALIGNMENT AND ADJUSTMENT
Align and adjust the door if it is not level or is not sealing
properly. If the door is not sealed, the unit may not cool
NOTICE
Properly aligned, the doors gasket should be
firmly in contact with the cabinet all the way
T-25 Torx Screw
! CAUTION
Do not attempt to use the door to raise or pivot
Door Adjustments 1
USER GUIDE
u-line.com
Door Adjustments 2
USER GUIDE
u-line.com
First Use
All U-Line controls are preset at the factory. Initial startup
requires no adjustments.
NOTICE
U-Line recommends discarding the ice produced
during the first two to three hours of operation
to avoid possible dirt or scale that may dislodge
from the water line.
When plugged in, the unit will begin operating under the
factory default setting. Follow the on screen prompt for
language selection and temperature units.
First Use 1
USER GUIDE
u-line.com
Control Operation
Zone Toggle
Up
Select
ICE PRODUCTION
Power
U-Select Lighting
Down
COMMAND
DISPLAY/OPTIONS
OFF
Press
and hold
ON
Press
and release
Adjust lighting
Press
to adjust lighting
Press
or
Customer menu
Press
Press
or
Service menu
Press
or
Press
or
U-SELECT CONTROL
2. Press
Digital Display
or
U-Select Lighting
3. Press
4. To exit, press
out.
Up
Select
CUSTOMER MENU
The 3000 Series of U-Line undercounter refrigeration
appliances contains a feature rich customer menu. The
Down
Power
U-Select Lighting
1. To begin, press
Control Operation 1
USER GUIDE
u-line.com
Up
Select
WELCOME TO THE
CUSTOMER MENU. USE
UP/DOWN ARROWS TO
SCROLL SETTINGS.
Select
ICE PRODUCTION
(12m remaining)
Down
Down
for 5 seconds.
2. Press
or
3. Press
to scroll to the
2. Press
to select Exit.
3. Press
Actual Temps
Up
Select
RETURN TO MENU
ACTUAL TEMPS
BIN TEMP = 1.6
COND TEMP = 45.5
4. Press
or
5. Press
Down
and select
Return to Menu.
and select
to Off.
2. Press
or
and select
Return to Menu.
Control Operation 2
USER GUIDE
u-line.com
2. Press
Up
Select
RETURN TO MENU
LANGUAGES
ENGLISH
3. Press
or
4. Press
Down
Fahrenheit / Celsius
Up
Select
2. Press
to select English.
4. Press
or
Menu.
languages.
1. Press
5. Press
to select Degrees.
Sound Level
3. Press
Up
Select
RETURN TO MENU
SOUND LEVEL
HIGH
or
(Celsius).
4. Press
Down
1. Press
or
Control Operation 3
USER GUIDE
u-line.com
Clean Cycle
Up
Select
RETURN TO MENU
CLEAN CYCLE
CLEAN?
1. Press
2. Press
to select Silence?.
Down
1. Press
to select Cancel?.
2. Press
complete.
Ice Adjust
Up
Select
1. Press
2. Press
Silent Mode
Up
Select
RETURN TO MENU
SILENT MODE
SILENCE?
To adjust thickness:
1. Press
Down
2. Press
3. Press
thinner.
4. Press
Control Operation 4
USER GUIDE
u-line.com
RETURN TO MENU
Help
Model 3018CLR
1-800-779-2547
Down
or
information.
To return to the Customer Menu, press
Return to Menu and press
to select
to confirm.
Control Operation 5
USER GUIDE
u-line.com
Ice
Cube Types
NOTICE
Ice thickness adjustment should only be made
1/4" TO 1/2"
(6.4 mm to 12.7 mm)
DIMPLE
1/16" TO 1/8"
(1.6 mm to 3.2 mm)
ICE BRIDGE
THIN BRIDGE
DEEP DIMPLE
THICK BRIDGE
LITTLE OR
NO DIMPLE
DIMPLES
ICE BRIDGE
Ice 1
USER GUIDE
u-line.com
RETURN TO MENU
ICE ADJUST
ICE ADJUST = 0
Down
1. Press
and
Customer Menu.
2. Press
3. Press
4. Press
thinner. Press
Ice 2
USER GUIDE
u-line.com
Sabbath Mode
1
Up
Select
Down
1. Press
2. No new ice will form when the unit is off, but previously
made ice will still be accessible/present for over 24
hours. Pump equipped models will continue to remove
water as needed even if the unit is off.
is pressed again
Sabbath Mode 1
USER GUIDE
u-line.com
USER GUIDE
u-line.com
Cleaning
EXTERIOR CLEANING
Integrated Models
To clean integrated panels, use household cleaner per the
cabinet manufacturers recommendations.
Stainless Models
Stainless door panels and handles can discolor when
exposed to chlorine gas, pool chemicals, saltwater or
cleaners with bleach.
INTERIOR CLEANING
Disconnect electric current to the unit.
cleaner.
! CAUTION
Cleaning 1
USER GUIDE
u-line.com
Evaporator
Water trough
! CAUTION
Never use anything to force ice from the
evaporator. Damage may result.
Evaporator cover
evaporator.
3. Remove evaporator
cover.
Cleaning 2
USER GUIDE
u-line.com
NOTICE
Discard all ice produced in the first harvest.
REFRESH KIT
Due to variations in water quality or inadequate
maintenance your unit may become excessively coated in
lime scale or calcium. U-Line offers a cost effective
refresh kit which replaces many interior components and
will return your unit to like new condition. Refresh kits
may be ordered from your local distributor and installed
by your local service company. For information on your
local distributor or service company please visit
www.u-line.com.
Cleaning 3
USER GUIDE
u-line.com
Cleaning Condenser
INTERVAL - EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille
(plinth strip/base fascia) free of dust and lint, and clean
the condenser when necessary. Depending on
environmental conditions, more or less frequent cleaning
may be necessary.
! WARNING
Disconnect electric current to the unit before
cleaning the condenser.
NOTICE
DO NOT use any type of cleaner on the
condenser unit. Condenser may be cleaned using
a vacuum, soft brush or compressed air.
Condenser
Cleaning Condenser 1
USER GUIDE
u-line.com
Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN
extended non-use:
! CAUTION
Damage caused by freezing temperatures is not
covered by the warranty.
WINTERIZATION
If the unit will be exposed to temperatures of 40F (5C)
or less, the steps above must be followed. In addition, P60
drain pumps in clear ice machines must be drained
according to the following procedure:
Extended Non-Use 1
USER GUIDE
u-line.com
Troubleshooting
IF SERVICE IS REQUIRED
If you do not understand a troubleshooting remedy, or
your product needs service, contact U-Line Corporation
directly at +1.800.779.2547.
When you call, you will need your product Model and
Serial Numbers. This information appears on the Model
and Serial number plate located on the interior of your
product or can be accessed through Help in the
TROUBLESHOOTING GUIDE
! DANGER
ELECTROCUTION HAZARD. Never attempt to
repair or perform maintenance on the unit
before disconnecting the main electrical power.
Customer Menu.
Problem
Digital Display
and Light Do
Not Work.
Interior Light
Does Not
Illuminate.
unfamiliar.
Light Remains
on When Door
Is Closed.
Unit Develops
Condensation
on External
Surfaces.
Digital Display
Functions, But
Unit Does Not
Produce Ice.
Digital Display
Shows an
Error.
Ice Is Too
Thick/Thin
Poor Ice Quality Unit may not be level. Check if unit is level.
Ice maker may be dirty. Clean ice maker.
Troubleshooting 1
USER GUIDE
u-line.com
No Ice
Production
Not Enough Ice Ensure the condenser coil is clean and free of
any dirt or lint buildup.
Water in Bin
Hear Running
Water
Hear Ice Falling After each harvest, ice will fall into the bin.
ERROR NOTIFICATION
The 3000 model series continuously monitors a series of
inputs and parameters to ensure proper and efficient
operation of your unit. Should the system detect a fault, an
error notification will be displayed on the user interface.
See below for a list of errors.
ID
Description
Solution
No Comm
Unit lost
communication to
the display.
Disconnect and
reconnect power to
unit. Contact Customer
Care if persistent.
Zone T Open
Contact Customer
Care.
Contact Customer
Care.
Zone T Short
Contact Customer
Care.
Troubleshooting 2
USER GUIDE
u-line.com
Warranty
Warranty 1
USER GUIDE
u-line.com
Warranty 2