Académique Documents
Professionnel Documents
Culture Documents
KIT
4450758746 - INSTRUCTIONS FOR 5635-K100-V001 HAWK
PRESENTER DUAL SENSOR UPGRADE KIT (603-6231668)
New part number for NGBN (next gen bank note) AU upgraded Presenter. This presenter is upgraded
version with the 2 Exit sensors + divert flipper assembly all installed
PN 8770315246 - MODULE SPRAY ASSY 230V AU UPGRADE FOR NGB
New part number for the Double Pick Module upgraded
PN 8770314899 - MODULE DOUBLE PICK AU CURRENCY UPGRADED
The Single Pick Module remains unchanged.
Table of Contents
1.
INTRODUCTION..............................................................................................................................................................................3
ABOUT THIS DOCUMENT........................................................................................................................................................................3
KIT INSTALLATION TIME..........................................................................................................................................................................3
TOOLS REQUIRED...................................................................................................................................................................................3
PACKAGE DETAILS..................................................................................................................................................................................3
1. INTRODUCTION
The Kit includes the parts required for upgrading the Hawk presenter for dual sensors.
Installation includes - Power the ATM down through proper shutdown process.
Tools Required
The tools required to install this kit are:
o
Pozidrive no 0 Screwdriver
Pozidrive no 2 Screwdriver
Package Details
o
Weight:
0.5Kg
No.
Description
Part No
Q'ty
445-0736455
445-0730869
Cable Tie
007-9714401
10
Circlip 5mm
009-0002367
2. Fitting Instructions
1. Perform Shutdown and power down ATM
2. Following local procedure open the safe.
3. Rack out the Dispenser Assy.
4. Remove dispenser control board cover (4 screws) Fig. 1
This document
Control board
cover screws
Fig. 1
Control board
screws
Fig 2
Connector
P6
Senso
r
Tie wraps
Senso
r
Fig. 3
Tie wraps
9. Remove front sensor bracket (2 screws each side) and attached harness. Fig. 4 and 5
Front sensor
bracket
Front sensor
bracket
screws
Fig. 4
Fig. 5
10. Remove screws securing divert solenoid and retain, screws (2) are on the inside of the frame. Fig. 6. The divert
solenoid can hang, it need not be removed from the dispenser.
Solenoid
screws
Fig. 6
Solenoid flag
Sensor
gap
Sensor
Solenoid
Fig. 7
11. Remove the double gear and belt from the left side frame. Take care when first removing C clip and Pin and
retain for reuse. Fig. 8.
Double gear
C clip
Fig. 8
12. Loosen Tie bar screws (2) and slightly open both side frames. Fig. 9
13. Remove (2) screws (1 per side) from the divert gate shaft. Fig. 9
14. Remove C Clip from the front drive shaft on the side frame, and retain for reuse. Fig. 9
C Clip
Fig. 9
15. Remove C Clip from the front drive shaft on the side frame, and retain for reuse.
16. Remove the divert gate assembly (remove shaft from the left side first and then from the right side). Fig. 10
Divert gate
assy
Fig. 10
17. Install new divert gate assembly. Make sure the divert gate goes below the shaft as shown in picture. Fig. 11 and
above the shaft shown in Fig. 12.
Fig. 11
Fig. 12
Fig. 13
Fig. 14