The air compressor relay is mounted in a relay module next to the power distribution box. The compressor relay is needed because the control module cannot directly provide the high current needed to run the compressor motor. It operates as follows: The control module (5A919) powers Circuit 420 to energize the relay coil. When energized, the coil creates a magnetic field that closes the relay contacts, connecting Circuit 1053 to Circuit 417. High current then flows from battery to the compressor motor.