Vous êtes sur la page 1sur 1

Repair info

DCX2496

Problem

Possible cause

Solution / repair hint

crackling, audio cutting out

poor connection at ribbon cables


074-00040-70720 X2 - 20 Pole 70mm
074-00041-80726 X13 - 26 Pole 180mm

replace ribbon cable and re-solder connections

sometimes no function

dry solder joint (in most cases bottom side)

PCB needs to be resoldered

Bad contact to EPROM or faulty EPROM


check that EPROM is correctly seated, replace faulty EPROM, update with
unit does not boot after power on, not possible to reload OS (012-14630-20140)
most recent version of OS (V1.40)
The 26 poles push-on terminal strip X13 and the 20poles push-The contact strips should be insulated with spacers
interruptions of the audio signal.
on terminal strip X14 on the IN/OUT board, can be short
circuit caused by plugging the XLR jacks ( IN and OUT) into
the rear board and thus comes to interruptions of the audio
signal.

DCX2496_REPAIR_TIPS_REV_B.xls

Vous aimerez peut-être aussi