Vous êtes sur la page 1sur 11

aspenONE V8.

8, AspenTechs WebBased User Interface

Release Notes

Version Number: V8.8


May 2015
Copyright (c) 2011-2015 by Aspen Technology, Inc. All rights reserved.
Aspen Data Source Architecture, Aspen HYSYS, Aspen Plus, aspenONE, aspenONE Platinum, aspenONE Process
Explorer, aspenONE Simulation Services, and the aspen leaf are trademarks or registered trademarks of Aspen
Technology, Inc., Bedford, MA.
One or more of the components listed in the enclosed THIRDPARTYREADME file may be included in this program.
Any such component is subject to the notices, license agreement, and terms and conditions applicable to such
component set forth in the THIRDPARTYREADME file.
All other brand and product names are trademarks or registered trademarks of their respective companies.
This document is a guide for using AspenTech's software. This documentation contains AspenTech proprietary and
confidential information and may not be disclosed, used, or copied without the prior consent of AspenTech or as set
forth in the applicable license agreement. Users are solely responsible for the proper use of the software and the
application of the results obtained.
Although AspenTech has tested the software and reviewed the documentation, the sole warranty for the software
may be found in the applicable license agreement between AspenTech and the user. ASPENTECH MAKES NO
WARRANTY OR REPRESENTATION, EITHER EXPRESSED OR IMPLIED, WITH RESPECT TO THIS
DOCUMENTATION, ITS QUALITY, PERFORMANCE, MERCHANTABILITY, OR FITNESS FOR A PARTICULAR
PURPOSE.
Aspen Technology, Inc.
20 Crosby Drive
Bedford MA 01730
USA
Phone: (1) (781) 221-6400
Toll Free: (888) 996-7100
URL: http://www.aspentech.com

Contents
About these Release Notes......................................................................................1
About aspenONE ..............................................................................................1
Related Documentation .....................................................................................2
Whats New in aspenONE V8.8 ................................................................................3
aspenONE Drive .....................................................................................3
Known Issues in aspenONE V8.8 .............................................................................4
Installation and Configuration Issues ..................................................................4
General Usability Issues ....................................................................................5
Administration Issues .......................................................................................6
Issues Found with Aspen Plus ............................................................................6
Issues Found with Aspen HYSYS ........................................................................6
Issues found with the iPad.................................................................................7

aspenONE V8.8 Release Notes

iii

iv

aspenONE V8.8 Release Notes

About these Release Notes

These release notes provide information about the aspenONE V8.8 release.
aspenONE is a unified web and mobile environment for searching, sharing,
viewing, interacting, and collaborating using the content produced by Aspen
Techs engineering, manufacturing, and supply chain products. Your
organization can effectively collaborate with anytime and anywhere access to
plans, schedules, simulations, and production performance data.
These Release Notes include the following sections:

About aspenONE

Related Documents

Whats New in aspenONE V8.8

Known Issues in aspenONE V8.8

About aspenONE
aspenONE is a unified web and mobile environment for searching, sharing,
viewing, interacting, and collaborating using the content produced by Aspen
Techs engineering, manufacturing, and supply chain products. Using
aspenONE, your organization has anywhere anytime access to plans,
schedules, simulations, and production performance information to
collaborate effectively. Anytime anywhere access also provides access from
any device connected to your network, and lets you do your work when you
are not at your desk.
The aspenONE Web interface provides easy access to Aspen Techs products
from a web browser, anywhere, anytime. With aspenONE applications for
Simulations, PIMS Platinum, and aspenONE Process Explorer, you can find
and run simulations, view and execute plans, view schedules and compare
with plans, see real-time plant data, save your work at any point, and pick up
where you left off on another device without having to install additional
software on your computer.

aspenONE V8.8 Release Notes

Related Documentation
In addition to these Release Notes, AspenTech provides the following
documentation for aspenONE V8.8.

aspenONE V8.8, AspenTechs Web-Based User Interface, Installation,


Configuration, and Implementation Guide

aspenONE Help

aspenONE Simulation Help

aspenONE Quick Reference pages

aspenONE Online Help

aspenONE Simulation Help

aspenONE Process Explorer Help

Aspen Plus and Aspen HYSYS for more information about simulations and
aspenONE Drive

aspenONE Process Explorer Installation and Configuration guides

aspenONE PIMS Platinum Help

aspenONE PIMS Platinum Installation and Configuration guides

Note: For updated versions of documents, go to the Aspen Tech Support Web
site.

aspenONE V8.8 Release Notes

Whats New in aspenONE


V8.8

aspenONE Drive
aspenONE Drive is a feature in Aspen Plus and Aspen HYSYS V8.8 that allows
model authors to upload and access their models and those shared by other
users from any device on the company network. Model authors can keep
models private or share with specific colleagues and, if required, choose to
prevent the model from being downloaded, thus protecting intellectual
property. Shared users receive an email containing a link to the model on
aspenONE Drive where they can search for models, download models to their
desktop (if enabled) or view and run models on the web.
To get started with aspenONE Drive, install aspenONE Web Server
(Engineering DVD 1) on any PC/server on the network, and enter the URL for
the server on the aspenONE Drive page in Aspen Plus or Aspen HYSYS. To
use aspenONE Drive, you must be a member. You can request membership
by entering the URL in a web browser and clicking the Request Membership
button.

aspenONE V8.8 Release Notes

Known Issues in aspenONE


V8.8

This section describes the Known Issues in aspenONE V8.8. If you encounter
a problem not listed in the following tables, see the troubleshooting section of
the aspenOne Installation, Configuration, and Implementation Guide.
This chapter is divided into the following sections:

Installation and configuration issues

General usability issues

Administration issues

Aspen HYSYS issues

Aspen Plus issues

iPad Issues

Installation and Configuration


Issues
There are no configuration issues for this release.

aspenONE V8.8 Release Notes

General Usability Issues


The following general usability issues are in the V8.8 release.
CQ Number

Description

Recommended Solution

00561064

Cannot run some Gas models


from Aspen Plus or Aspen
HYSYS.

Save these models again


in V8.8 Aspen HYSYS and
not in aspenONE.

00562998

For some models, aircooler.hsc


for example, if you change a
stream input directly from the
stream, and then change the
same input variable on the
model table, the results update
but the stream continues to
display what the user entered
the first time.

Ensure that an input


variable is only changed in
one location before
running the case if the
variable exists in multiple
data tables.

00563198

When you select certain


templates, the stream table
displays duplicate variables
multiple times, and the
template variables are not
highlighted in blue.

No workaround.

00564532

aspenONE uses Windows


Authentication which fails on
Safari iOS 8 but works in the
latest version of Chrome.

Use the latest version of


Chrome.

00582613

V8.8 upgrade not persisting


the previously defined number
of adaptors.

To change the number of


adaptors, check the
Adding and Removing
Adapters from aspenONE
Simulation Services for
Aspen Plus and HYSYS
topic in the aspenONE
Installation and
Configuration guide.

00582726

Date settings on foreign


platforms are displayed in the
US format.

No workaround.

00582490

Saved Models migrated from


V8.6 to V8.8 are not displayed
correctly when opened in the
Simulation application.

No workaround.

00583204

Cannot overwrite active tag


mappings.

Manually correct the tags


that not get updated from
importing.

00579755

aspenONE V8.8 Release Notes

Administration Issues
There are no Administration Issues in this release.

Issues Found with Aspen Plus


There are no issues with Aspen Plus in this release.

Issues Found with Aspen


HYSYS
There are no issues with Aspen HYSYS in this release.

aspenONE V8.8 Release Notes

Issues found with the iPad


The following issues exist with the iPad in the V8.8 release.
CQ Number

Description

Recommended Solution

00549825

When using Safari on an iPad, the


aspenONE Simulation application
does not pass the correct
credentials or no credentials with
its requests to aspenONE Process
Explorer.

Use the Google Chrome browser


on an iPad.

When this happens, the aspenONE


Simulation application fails to get a
data source from the registered
plant data URL.
00551609

When using Chrome, in the Live


Pant Data Service panel, the Plant
Data source URL cannot be
modified easily.

Delete all values for the Plant


Data configuration and enter the
modified information for all fields
again

00552185

If you are bound to a model when


the iPad goes into lock mode (slide
to unlock idle screen), you are
actually unbound when you unlock
the screen. However, aspenONE
Simulation indicates that you are
still bound to the model and the
Simulation panel remains open,
and the status indicates results are
available.

Leave the current PFD and enter


another PFD to reset and close
the aspenONE Simulation panel.

You cannot close the aspenONE


Simulation panel.
00563198

When you select certain templates,


the stream table displays duplicate
variables multiple times, and the
template variables are not
highlighted in blue.

No workaround.

00563209

In Safari, when you use the + or


in the Zoom Panel, the PFD
disappears.

Tap the screen and the PFD


appears. After you tap the
screen, tapping the + or key in
the Zoom panel works.

00563210

In Safari, when you double-tap on


the PFD to reset it, the PFD goes
off screen.

Scroll to down and to the right to


see the PFD.

00584222

iPad Safari - Saved Simulation


model with table open; not opening
on center of Ipad.

To avoid this issue, save your


model before opening any
tables. This only needs to be
done the first time you save your
model.

00580588

aspenONE V8.8 Release Notes

Vous aimerez peut-être aussi