Vous êtes sur la page 1sur 18
CHAPTER-12 CONTENTS 01802 Flanged Volume Control Dampers - Model VCD-F1. 03 & 04 Flanged Volume Control Dampers - Model VCD-F2. 05 & 06 Flanged Volume Control Dampers - Model VCD-F3. 07808 Slip and Clip Volume Control Dampers - Model VCD-S1. 09810 Slip and Clip Volume Control Dampers - Model VCD-S2. 11812 Slip and Clip Volume Control Dampers - Model VCD-S3. 13 &14 Round Volume Control Dampers - Model VCD-R. 15 Ordering Data. VOLUME CONTROL DAMPER Features & Characterstics * VCD - FI single or mulfi- leat dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units. + Dampers are ruggedly built, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. * The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. * available in wide variety of standard duct sizes ranging from 100 x 100 mm up. to 1200 x 1200 mm in 50 mm increments (other non = standard sizes are available on request. * Any size combination with a height up to 150 mm is manufactured in single blade unit. Other sizes are manufactured in mutfi blades unit. Cet tet Td Frame : Galvanized steel , 16 or 18 gauge depending on damper size. Formed channel for flanged connection. Flange Width : 30 mm (standard). Blades : Extruded Aluminium, double skin with aetofoil section. Finish: Frame : Mill Galvanized, Blades : Mill Aluminium, ‘Axle : Blades rotating around its centre by means of zinc plated steel connecting axle (Spinaie} Bearings : Blades are fixed with the frame by means of plastic bushes. linkage : Zinc plated steel side mounted linkage concealed inside the frame. Blades Seal : As on option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation, Hand Locking Quadrant : Unless otherwise required, all dampers are equipped with extemal galvanized steel hand quadrant as standard to : - Adjust damper opening position. - Indicate damper opening position. - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size : 100 x 100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independently. Cireserves ne right to make changes without por notice. vo-o1 VOLUME CONTROL Di iC RVeD aa} CCCI React Melt) (© Fanges Caung @ Acroto’ Blade, @ Hand tocking avoctont @ tntoge See. © Prosic ating. @ Londing Andie. 1ooisomnm _) 30mm = j aS Parailol Blades Opposed Blades (Side View) (Gide View) Pressure Drop AP: (Pa) Velocity Vt (m/s) fotal Pressure Drop, Face Velocity based on damper cross-sectional ares. jades cefection angle, blades are fully open at w= 0°. serves the ight ta make change without eo vo-02 VOLUME CONTROL DAMPERS) Mot a7) Square or Rectangular ry oh Pee eer] Peoria) CR lades Operation | Manval (Parallal or Opposed) Features & Characterstics * VCD -F2 single or multi- leaf dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units + Dampers are ruggedly bull, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. * The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. * Avaliable in wide variely of standard duct sizes ranging from 100x100 mm up to 1200 x 1200 mm in $0 mm increments (other non = standard sizes are available on request, * Any size combination with a height up to 250, mm is manufactured in single blade unit Other sizes are manufactured in multi blades unit. Cot trot ed Frame : Galvanized steel , 16 or 18 gauge depending on damper size, Formed channel for fianged connection. Flange Width : 30 mm (standard). Blades : Galvanized steel sheet, double skin with aerofoil section. Finish: Frame : Mill Galvanized, Blades : Mill Aluminium. Axle : Blades rotating around its centre by means of zinc plated steel connecting axle (Spinate} Bearings : Blades are fixed wilh the frame by means of plastic bushes. linkage : Zinc plated steel side mounted linkage concealed inside the frame. Blades Seal : As an option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation. Hand Locking Quadrant : Unless otherwise required, all dampers are equipped with extemal galvanized steel hand quadrant as standard to : - Adjust damper opening position. - Indicate damper opening position. - Lock the blades at the desired position, ‘Aso, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size : 100x100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independently. AaCireserves ne right to make changes without por notice. vo-03 VOLUME CONTROL Di itt R el ea) CCCI React Melt) (© Fanges Caung @ Acrotod Blade, @ Handtocking Questo! @ tntoge See. © Prose sarin. @ Londing Andie. 1ooisomnm _) 30mm = j aS Parailol Blades Opposed Blades (Side View) (Side View) Pressure Drop AP: (Pa) Velocity Vt (m/s) fotal Pressure Drop, Face Velocity based on damper cross-sectional ares. jades defection angle, blades are fully open at w= 0°. serves the ight ta make change without ero vo-04 VOLUME CONTROL DAMPERS: Not Ea) Reo Seid ry oon ENR CR cy lades Construction CCR lades Operation | Manual (Parallal or Opposed) Features & Characterstics + VCD - F3 single or multi- leaf dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units. + Dampers are ruggedly built, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. + The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. + Available in wide variety of standard duct sizes ranging from 100 x 100 mm up to 1200 x 1200 mm in 50 mm increments (other non = standard sizes are available on request. + Any size combination with a height up to 250 mm is manufactured in single blade unit. Other sizes are manufactured in multi blades unit, Cot et ead Fame : Galvanized steel, 16 or 18 gauge depending on damper size. Formed channel for fanged connection. Flange Width : 30 mm (standard) Blades : Galvanized steel sheet, " 3V" formed, single skin blades. Finish: Frame : Mill Galvanized. Blades : Mill Galvanized. Axle : Blades rotating around its centre by means of zinc plated steel stud. Bearings : Blades are fixed wilh the frame by means of plastic bushes. linkage : Zinc plated steel side mounted linkage concealed inside the frame. Blades Seal : As an option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation Hand Locking Quadrant : Unless otherwise required, all dampers are equipped with external galvanized steel! hand quadrant as standard to : - Adjust damper opening position. - Indicate damper opening position. - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size : 10x 100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independently Cireseres ne right to make changes wihout por notice. vo-05 VOLUME CONTROL Di LUTE Ales 3 (© Fanges Caung @ -2V-Formes, Single Skin Blade. @ Hand Locking avoctont 109180 om 20mm Posie Bearing. © Inc Plated steel tus © Londing Aral. Parailal Blades Opposed Blades (Side View) (Side View) eeu ca ue) ure Drop AP: (Pa) a AP: = Total Pressure Drop. Velocity Vt (m/s) Face Velocity based on damper cross-sectional ares. = Blades defection angle, blades are fully open at &= O°. Cireserves ne right to make changes without pror notice. vo-06 VOLUME CONTROL DAMPERS: ole Square or Rectangular ry Ake SEE] | iaded atmo | lades Operation f Manval (Parallal or Opposed) Features & Characterstics * VCD -S1 single or multi- leaf dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units + Dampers are ruggedly bull, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. * The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. * Avaliable in wide variely of standard duct sizes ranging from 100x100 mm up to 1200 x 1200 mm in $0 mm increments (other non = standard sizes are available on request, * Any size combination with a height up to 150, mm is manufactured in single blade unit Other sizes are manufactured in multi blades unit Ct et eT dr Frame : Galvanized steel , 16 or 18 gauge depending on damper size. Formed for Sip ‘ond Clip connection to ductwork, Blades : ExIruded Aluminium, double skin with aerofoil section. Finish Frame : Mill Galvanized. Blades : Mill Aluminium. ‘Axle : Blades rotating around its centre by means of zinc plated steel connecting axle (Spinaie} Bearings : Blades are fixed with the frame by means of plastic bushes. linkage : Zinc plated steel side mounted linkage concealed outside the frame. Blades Seal : As an option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation, Hand Locking Quadrant ; Unless ofherwise required, all dampers are equipped with external galvanized steel hand quadrant as standard to : - Adjust damper opening position. - Indicate damper opening position. - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size: 100x 100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independently, Cireserves ne right to make changes without por notice. vo-07 VOLUME CONTROL Di rR eD ey LCCC LT Meco tI) © casing, ® Acrfol ace, @ Lineage sie. © Posie soaring @ Landing angle @ Hond Locking Guadiont \ | 944 | Sy 4 C Ve arate Blades (Side View) Opposed Blades (Side View) eeu cue) Pressure Drop AP: (Pa) Velocity Wt (m/s) fotal Pressure Drop, Face Velocity based on damper cross-sectional area. jades defection angle, blades are fully open at &= 0°. Le serves the ight to make change without ero vo-08 VOLUME CONTROL DAMPER VeD - $2 Square or Rectangular cy Ake lades Operation ff Manval (Parallal or Opposed) Features & Characterstics * VCD - $2 single or multi- leat dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units + Dampers are ruggedly buill, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. * The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. * Avaliable in wide variely of standard duct sizes ranging from 100x100 mm up to 1200 x 1200 mm in $0 mm increments (other non = standard sizes are available on request, * Any size combination with a height up to 250 mm is manufactured in single blade unit Other sizes are manufactured in multi blades unit Ct et eT dr Frame : Galvanized steel , 16 or 18 gauge depending on damper size. Formed for Sip ‘ond Clip connection to ductwork, Blades : Galvanized steel sheet, double skin with aerofoil section. Finish: Frame : Mill Galvanized. Blades : Mill Galvanized. ‘Axle : Blades rotating around its centre by means of zinc plated steel connecting axle (Spinaie} Bearings : Blades are fixed with the frame by means of plastic bushes. linkage : Zinc plated steel side mounted linkage concealed outside the frame. Blades Seal : As on option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation, Hand Locking Quadrant ; Unless oherwise required, all dampers are equipped with external galvanized steel hand quadrant as standard to : - Adjust damper opening position. - Indicate damper opening position. - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size: 100x 100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independentty, Cireserves neigh to make changes without efor notice. vo-09 Wetcrocsioe BCcY Model VCD - $2 CIRC L M Ecole t UC) © cosing, ® Acrofi dacs, @ Hond Locking Guadiont HH @ seiage ste Parla Blades oppoted blades @ Posie Searing, ~s| {Side View) ‘Gide @ Londra ale eu cu ue Ce) 2000 7 Pressure Drop AP: (Pa) APs = Total Pressure Drop. VW = Face Velocity based on damper cross-sectional areo, ° = Blades defection angle, blades are fully open at &= 0°. Velocity Vt (m/s) VOLUME CONTROL DAMPERS: zk KeD03 lades Operation Manual (Parallal or Opposed) Features & Characterstics * VCD - $3 single or multi- leat dampers have been specifically designed for use in ventilation systems for volume, flow and pressure control in square and rectangular ducts and air handling units * Dampers are ruggedly bull, with a casing of robust assembly formed from channel frame for flanged connection to ductwork. * The blades design provides lower pressure drop in the open position for smooth motion with reduced turbulence. * Avaliable in wide variely of standard duct sizes ranging from 100x100 mm up to 1200 x 1200 mm in $0 mm increments (other non = standard sizes are available on request, * Any size combination with a height up to 250, mm is manufactured in single blade unit Other sizes are manufactured in multi blades unit. Cot et ed Frame : Galvanized steel , 16 or 18 gauge depending on damper size. Formed for slip and Clip connection to ductwork. Blades : Galvanized steel sheet," 3V" formed, single skin blades. Finish Frame : Mill Galvanized. Blades : Mill Galvanized. Axle : Blades rotating around its axis by means of zinc plated steel stud. Bearings : Blades are fixed with the frame by means of plastic bushes. Linkage : Zinc plated steel side mounted linkage concecled in the frame. Blades Seal : As an option, blades rubber gasket seal at one edge is available on request to seal blade to blade joint for low air leakage operation Hand Locking Quadrant : all dampers are equipped with external galvanized steel hand quadrant to : - Adjust damper opening position. - Indicate damper opening position, - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator assembly. Minimum Size : 100x100 mm. Maximum Size : 1200 x 1200 mm as a single section. Multiple section assembly is unlimited where each section operates independently Cireseres ne right to make changes wihout por notice. vo-11 VOLUME CONTROL D. BCr Model VC! © caine @ "20" Fermed, Sng Sen ode @ sand Locking Quast! oustem oY ced ot » 7 >» i N S . eH Y N 1 ail Fee Se a Ie L HAL @ Linkage Siae. © Plastic Bearing. Dircrowaseins | ® Landing Angle. Parailal Blades Opposed Blades (Side View) (Side View) eeu cae Ce) L” ure Drop AP: (Pa) a fotal Pressure Drop, Face Velocity based on damper cross-sectional ares. X= Blades defection angle, blades are fully open at & = 0° Velocity Wt (m/s) Craters ne right to make changes without por notice. vo-12 VOLUME CONTROL DAMPERS) =e ac i os Pe Melt eet tard * VCD -R round type volume control dampers have been specifically designed for the use in circular duct installations and at the con- nections between flexible ducts and the inlets of supply air plenums to regulate air flow and control pressure. + Also these dampers can be used as Shut - Off dampers when sealing against air flow is required. + Available with open : - Grooved Ends or, - Straight Ends. * Available in wide variety of standard duct sizes ranging from 100 mm @ up to 600 mm @ in 50 mm increments (ot tet Casing : Galvanized stee! , 18 or 20 gauge depending on damper size. Circular formed for circular duct connections. Ends Type : Open Grooved Ends or, Open Straight Ends. Blade : Galvanized steel formed, single skin blade. sheet, circular Finish: Casing : Mill Galvanized. Blade : Mill Galvanized. Axle : Blade rotating around ils centre by means of zinc plated steel connecting axle (Spindle). Bearings : Blade are fixed with the frame by means of plastic bushes. Hand Locking Quadrant : Unless otherwise required, all dampers are equipped with external galvanized steel hand quadrant as standard to : - Adjust damper opening position. - indicate damper opening position. - Lock the blades at the desired position, Also, dampers are available with extended steel shaft suitable for electrical actuator ‘assembly. Minimum Size : Maximum Siz Cireserves neigh to make changes wihout por notice. vo-13 VOLUME CONTROL D. BCcr b2imm) ° ‘Open Grooved Ends | =| a ® Cosing, ® Blade. @ Prosc Boating, ‘Open Sraight nds ® Hand Locking Quaarant. ® Groove. D : Duct diameter Size in (mm). Engineering & Performance Data Se & » i % (otal Prossure Drop, 108 Velocity based on damper cross-sectional ates. jade defection angle, blade are fuly open at = 0% Ree Velocity Vt (m/s) CIreserves the right to make changes wihout por notice vo-14 VOLUME CONTROL DAMPERS ree ¢ Ordering Specifications : Specify : 1 2 3 4 . VCD - Model (VCD-F1,F2,F3,S1... Duct Size. Quantity VCD). o 6 . Blades Seal Rubber Gasket (Optional Accessories). Example 1: 1 2 veD-i 300 x 200 2 (mm) Example 1 2 3 2A" x16) vep-s1 600 x 400 5 (mm) Example 3: 1 2 3 . 10" VoOR 250 mm @ 0 CI reserves he nght fa make changes without prornatce, Parallel Opposed Type of Ends, Grooved or Straight (only mention for the Model VCD-R). Grooved Ends BCY . Blades operation, Parallel or Opposed type|this specification is not applicable for the Model With Blades Seal BC BEST CHOICE INDUSTRIES L.L.C. MANUFACTURING CENTRAL AIR CONDITIONING AIR OUTLETS Tel, :04 3471571 - Fox: 04- 3471671 - P.O. Box: 31567, Dubai - U, A. E,- E-mail: bei@emirates.net.ce

Vous aimerez peut-être aussi