Vous êtes sur la page 1sur 5

IS :10124

(Part6 )-1288

( Reaffirmed 1998 )

Indian Standard

SPECIFICATION FOR
FABRICATED PVC FITTINGS FOR
POTABLE WATER SUPPLIES
PART 5 SPECIFIC REQUIREMENTS FOR EQUAL TEES

( First Revision )
FirstReprint0CTOBERm1993

UDC 621.643.4.062.2[678.743.221:696.117

@I Copyright

BUREAU

OF

MANAK BHAVAN,

GT2

INDfAN

1989

STANDARDS

9 BAHADUR SHAH
NEW DELHI 110002

ZAFAR

MARG

February 1989

IS I 10124 ( Part 5 ) - 1986

Indian Standard
SPECIFICATION FOR
FABRICATED PVC FITTINGS FOR
POTABLE WATER SUPPLIES
P-ART 5

SPECIFIC REQUIREMENTS

FOR EQUAL

TEES

( First Revision)
0.

FOR

EWORD

0.1 This Indian Standard ( Part 5 ) ( First Revision ) was adopted


by the Bureau of Indian
Standards
on 20 June 1988, after the draft
finalized by the Sanitary Appliances and Water
Fittings Sectional Committee had been approved
by the Civil Engineering Division Council.

Part 9 Specific requirements


Part 10 Specific requirements

0.2 The fabricated PVC fittings are to be used


for jointing to the PVC pipes covered
in
IS : 4985-1988*.
0.3 The requirements of fabricated
are covered in following thirteen
standard:

PVC fittings
parts of the

for 300 bends


for 224 bends

Part 13 Specific requirements

for lit bends

0.4 For the purpose of deciding


whether a
particular requirement of this standard is complied with, the final value, observed or calculated
expressing the result of a test or analysis, shall be
rounded off in accordance with IS : 2-1960t. The
number of significant
places retained in the
rounded off value should be the same as that of
the specified value in this standard.

Part 5

Specific requirements for equal tees


Part 6 Specific requirements for flanged tail
pieces with metallic flanges
Part 7 Specific requirements for threaded
adaptors
Specific requirements

Part 11 Specific requirements


Part 12 Specific requirements

0.3.1 Part 1 of this series deals with the


general requirements applicable to all fabricated
PVC fittings and specific requirements of different types of fittings are covered in separate
parts of the standard. This standard ( Part 5 )
deals with the specific requirements for equal
tees. This part was first published in 1982. The
present revision has been taken up to extend the
size of fittings to 630 mm in line with the sixes
of pipes specified in IS : 49851988.

Part 1 General requirements


Part 2 Specific requirements for sockets
Part 3 Specific requirements
for straight
reducers
Pa;t 4 Specific requirements for caps

Part 8

for 60 bends
for 45 bends

for 90 bends

*Specificationfor unplastisiad PVC pipes for potable


water supplies ( secondrevision ).
*Specification for unplasticized PVC pipes for potable
tRules for rounding off numerical values ( reviscd ).
water supplies ( second revision ).

material, sizes, methods of test,


conformity
shall
criteria
for
IS : 10124 ( Part 1 )-1988*.

1. SCOPE
1.1 This standard
( Part 5 ) lays down the
requirements of manufacture,
dimensions and
marking for fabricated PVC equal tees for
potable water supplies.

The ~general requirements

and
to

2.2 Manufacture
2.2.1 A typical
shown in Fig. 1.

2. REQUIREMENTS
2.1 General

sampling
conform

illustration

of equal tee

is

*Specificationfor fabricated PVC fittings for potable


water supplies : Part 1 General requirements(
revision ).

for
I

Es: 10124(Part5)-1988

*PVCwelded by solvent or welding rod and with fibre glass reinforcement of 40 mm width and 3 mm minimum
thiilcness.
B I mean socket internal diameter at mid-point of socket length asspecified in IS : 10124 ( Part I )-1988*.
L - minimum socket length in accordance with IS : 10124 ( Part i )-1988*.
B = 1.45 X nominal out&do diameter of the pipe + 6 mm.

t - minimum wall thickness of equal tees calculated on the basis of 90 percent of the minimum wall thickness
of the corresponding size and pressure class of pipe rounded off to the next higher 0.1 mm.
Noru-The
drawing is only intended to define fho terms used
design features.
FIG.

in Table 1 and is not intended to illustrate specific

1 EQUAL TEE

22.2 Dimensions -The


dimensions of eaual
tees shall comply with those given in Tabld 1
read with Fig. 1.

TABLE '1DIMENSIONS OF EQUAL TEE


( Clause 2.2.2. and Fig. 1 )
All dimensions in millimetres.

NOTE- For pipes of 025 MPa pressure class, there


are no equal tees and for these, equal tees designed for
0.4 MPa may be used.

SIZE

Min

3. MARKING
3.1 Each equal tee fitting shall be marked
the following information:

a) W;;~facturers

name

(1)
63
75

with

90
110
125
140
160
180
200
225
250
280
315
355
400
450
500
560
630

or indentification

b) The size of the equal tee and the appropriate


class ( working
pressure ) of
IS : 4985-1988t to which the pressure
rating of the fitting corresponds, and

*Specification for fabricated PVC fittings for potable


water supplies : Part 1 General requirements (jirsr revision

).

t!$ecification for unplasticized PVC pipes for potabio


water supplies ( second revision ).

MINIMUM WALL THICKNESS ( t ) FOR


WORKINU PRESSURE
T_-_--h-----~
0.4 MPa
0.6 MPa
1.0 MPa
(Class 2 )
Class 3 )
( Class 4 )

(2)
98

c 3)
14

(4)
2.0

(5)
32

115
137
166
188
209
238
267
296
333
369
412
463
521
586
659
731
818
920

17
19
2.3
2.7
29
3.4
38
4.2
47
52
58
63
7.3
8.2
9.3
10.3
116
13.0

24
28
3.4
3.9
4.4
4.9
55
6.2
6.9
7.7
8.6
97
108
122
13.7
153
17.2
192

3.8
45
55
6.3
70
8.0
9.0
10.0
112
125
13.9
15.6
17.7
19.8
22.4
248
27.8
31.3

IS : 10124( Part 5 ) - 1988

NOTE- The use of the Standard Mark is governed


by the provisions of the Bureau of Indian Standards
Act, 1986 and the Rules and Regulations made theerunder. The Standard Mark on products covered b an
Indian Standard conveys the assurance that they ii ave
been produced to comply with the requirement8 of
that standard under a well defined system of inspection, testing and quality control which is devised and
supervised by BIS and operated by the producer.
Standard marked products are also continuously
checked by BIS for conformity to that standard aa a
further safeguard. Details of conditionrunder which a
liccnce for the use of the Standard Mark may bo
granted to manufacturers
or producers may be
obtained from the Bureau of Indian Standards.

C) The equal tee shall be marked in colour


as indicated below for different classes of
fittings:
Class of Fitting
Class 2 ( 04 MPa )

Colour

Class 3 ( 0.6 MPa )

Green
Yellow

Class 4 ( 10 MPa )
3.1.1 Each equal tee fitting
marked with the Standard Mark.

Blue

may

also be

Ihreao of Indian Standarda

BIS is a statutory institution established under the Bureau of Indian Standards Act, 2986 to
promote harmonious development of the activities of standardization, marking and quality
certification of goods and attending to connected matters in the country.
CopJrigbt

BIS has the copyright of all its publications. No part of these publications may be reproduced in
any form without the prior permission in writing of EIS. -This does not preclude the free use, in
the course of implementing the standard, of necessary details, such as symbols and sixes, type or
grade designations. Enquiries relating to copyright be addressed to the Director ( Publications ), BIS.
Rtrition of Indian Stwdards

Indian Standards are reviewed periodically and revised, when necessary and amendments, if any,
are issued from time to time. Users of Indian Standards should ascertain that they are in possession
of the latest amendments or edition.

Amendments bsaed Since Pablicrtioa

Amend No.

Text Affected

Date of Jssue

BUREAU 3F INDIAN STANDARDS


Headquarters :
Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110002
Telephones : 3310131, 331 13 75

Telegrams : Manaksanstha
( Common to all Offices )

Regional Offices :

Telephone

Central : Manak Bhavan, 9 Bahadur Shah Zafar Marg,


NEW DELHi 110002

I 331 01
13 31
75

Eastern : 1114 C. I. T. Scheme VII M, V. I. P. Road, Maniktola


CALCUTTA 700054
Northern : SC0 445-446, Sector 35-C CHANDIGARH

160036

Southern : C. I. I, Campus, IV Cross Road, MADRAS 600113


Western : Manakalaya, E9 MIDC, Marol, Andheri ( East )
BOMBAY 400093

37 86 62
21843
41~29 16
6 32 92 95

Branches : AHMADABAD. BANGALORE. BHOPAL. BHUBANESHWAR.


COIMBATORE. FARIDABAD. GHAZJABAD. GU WAHAT1.
HYDERABAD. JAIPUR. KANPUR. PATNA. TRIVANDRUM.
Reyrography Unit, BE, New Delhi, India