1. Technical Specification .............................................................................................................................................................. 6
1.1 Product Features ......................................................................................................................................................................... 6
1.2 Main function and technical features .................................................................................................................................... 6
1.2.1 Main function ....................................................................................................................................................................... 6
1.2.2 Technical parameter.......................................................................................................................................................... 7
1.2.3 Operational Environment ................................................................................................................................................ 7
2. Sketch map ..................................................................................................................................................................................... 8
2.1 Physical construction .................................................................................................................................................................. 8
2.2 Weight .............................................................................................................................................................................................. 8
2.3 Illustration of LED display ......................................................................................................................................................... 8
2.4 Sketch map of interfaces .......................................................................................................................................................... 9
2.4.1 Interface description: ........................................................................................................................................................ 9
2.4.2 Sketch map of I/O interface ........................................................................................................................................... 9
2.4.3 Schematic diagram of USB interface .................................................................................................................... 11
2.4.4 Description of feeder line(optional) ........................................................................................................................... 11
2.4.5 Network application connection diagram ................................................................................................................ 12
3. Installation instructions ........................................................................................................................................................... 13
3.1 Notes .............................................................................................................................................................................................. 13
3.2 Installation conditions ............................................................................................................................................................... 13
3.3 Device connection ..................................................................................................................................................................... 13
3.3.1 Connect power adapter ................................................................................................................................................. 13
3.3.2 Connect external antenna and RF cable ................................................................................................................ 13
3.3.3 PC connection................................................................................................................................................................... 14
3.4 Device installation ...................................................................................................................................................................... 14
3.5 Acceptance ................................................................................................................................................................................... 14

3.5.1 Acceptance of structure ................................................................................................................................................. 14


3.5.2 Performance acceptance .............................................................................................................................................. 14
4. Operating Instruction ............................................................................................................................................................... 15
4.1 Introduction of Demo software .............................................................................................................................................. 15
4.2 Demo software application environment ........................................................................................................................... 15
4.3 Demo software version ............................................................................................................................................................ 15
4.4 Demo software installation ..................................................................................................................................................... 15
4.5 Demo software operation ........................................................................................................................................................ 16
4.5.1 Connect the reader ......................................................................................................................................................... 16
4.5.1.1 Serial communication connection .................................................................................................................... 16
4.5.1.2 Network port communication connection ...................................................................................................... 17
4.5.1.3 RS485 communication connection.................................................................................................................. 18
4.5.1.4 USB communication connection ...................................................................................................................... 19
4.5.2 Data display area .......................................................................................................................................................... 19
4.5.2.1 Read EPC................................................................................................................................................................. 20
4.5.2.2 Read TID ................................................................................................................................................................... 20
4.5.2.3 Custom read ............................................................................................................................................................ 21
4.5.2.4 Stop read................................................................................................................................................................... 22
4.5.3 Write data............................................................................................................................................................................ 22
4.5.3.1 Write EPC data ....................................................................................................................................................... 22
4.5.3.2 Write user data ....................................................................................................................................................... 23
4.5.3.3 Custom tag action.................................................................................................................................................. 24
4.5.4 TCP server / client mode ................................................................................................................................................ 24
4.5.5 Antenna enable configuration ....................................................................................................................................... 25
4.5.6 Base band parameter configuration ........................................................................................................................... 26
4.5.7 Antenna port power setting ............................................................................................................................................ 27
4.5.8 Clock setting ........................................................................................................................................................................ 27

4.5.9 Frequency Hopping management............................................................................................................................... 28


4.5.10 Label filtering .................................................................................................................................................................... 29
4.5.11 Auto idle configuration ................................................................................................................................................... 30
4.5.12 GPI/O configuration ....................................................................................................................................................... 30
4.5.13 Advanced configuration ................................................................................................................................................ 32
4.5.14 Tools..................................................................................................................................................................................... 33
5. Common failures ........................................................................................................................................................................ 35
5.1 Daily maintenance ..................................................................................................................................................................... 35
5.2 Common failure analysis and solution ............................................................................................................................... 35
6. Packing accessories, transportation and storage ....................................................................................................... 37
6.1 Package ........................................................................................................................................................................................ 37
6.2 Accessories .................................................................................................................................................................................. 37
6.3 Storage environment ................................................................................................................................................................ 38
7. After-sale service ........................................................................................................................................................................ 39

1. Technical Specification
1.1 Product Features
CL7206C is a high performance four antenna port fixed UHF RFID reader and writer; support
ISO18000-6C/6B protocols. The work frequency includes China standard dual frequency 920MHz ~ 925MHz
and 840MHz845MHz, FCC 902MHz ~ 928MHz and ETSI 865MHz ~ 868MHz.
Output power from 0 ~ 33dBm optional, with long identification distance, fast reading speed, high accurate
rate, strong anti-interference ability, good protection performance and easy installation

1.2 Main function and technical features

1.2.1 Main function


Protocol: support ISO18000-6C/6B standard
Built-in LINUX operating system
Multiple communication port (Ethernet, RS232, RS485, USB)
Support tag data filtering
Support RSSI: the intensity of the perceived signal
Adjustable RF output power
Optional working mode: constant frequency / frequency hopping
Supports antenna detection function
Supports online and remote upgrade
I/O interface: 4 port opt coupler input, 4 port relay output and Weigand output

1.2.2 Technical parameter


Working frequency: GB 920MHz925MHz, GB 840MHz845MHz,
FCC 902MHz928MHz, ETSI 865MHz868MHz
Output power (port): 33dBm + 1dB (MAX)
Power adjustment: 1 dB step-by-step
Reading distance: 0 ~8meters (depending on tags, antennas and environment)
Channel bandwidth: <200 KHz
RS232 serial communication rate: 115200bps (default), 19200 bps, 9600bps
RS485 interface communication rate: 115200bps (default), 19200 bps, 9600bps
Support: Weigand 26, 34, 66 interfaces
Power supply: 30V ~ 10V (power capacity is not less than 60W)
Power adapter: AC input 100V ~ 50Hz, 240V ~ 60Hz
DC output: 24V/2.5A
High protection grade: IP54

1.2.3 Operational Environment


Working environment: -20+70
Relative Humidity: 5%RH90%RH+25

2. Sketch map
2.1 Physical construction

Image 2-1 Structure diagram of CL7206C2


Volume of four-port fixed rfid reader CL7206C2:
324mm*225mm*62mmaccessories excluded

2.2 Weight
About 2.6kgaccessories excluded

2.3 Illustration of LED display

Image2-2 Sketch map of readers LED indicator


LED indicator panel describe as below Form 2-1:

Form 2-1

LED indicator description

LED Mark NO.

Mark NO.

Status description

ANT1

Antenna 1 indicator

Indicates antenna 1 is working

ANT2

Antenna 2 indicator

Indicates antenna 2 is working

ANT3

Antenna 3 indicator

Indicates antenna 3 is working

ANT4

Antenna 4 indicator

Indicates antenna 4 is working

Status

Status indicator

Flashing indicates recognition to tags

POWER

Power indicator

Keep bright indicates power supply working normally

2.4 Sketch map of interfaces

Image 2-3 Sketch map of readers I/O and communication interface

2.4.1 Interface description:


1 - power interface
2 - network communication interface
3 - USB interface
4 - I/O interface
5 - RS232 communication interface
6 - Antenna interface (4 TNC connectors)

2.4.2 Sketch map of I/O interface

Image 2-4 Sketch map of I/O control interface


I/O control signal define as follow form 2-3
Form 2-3 I/O control signal definitions
Aviation pin

description of pin

pin definitions

Relay 1 output port

OUT_R1

Relay 2 output port

OUT_R2

Relay 3 output port

OUT_R3

Relay 4 output port

OUT_R4

optocoupler 1 external signal input positive

IO_INPUT1

optocoupler 3 external signal input positive

IO_INPUT3

optocoupler external signal input negative

IO_GND

Weigand output signal 0

Wiegand_DATA0

Weigand output signal 1

Wiegand_DATA1

10

ground

GND

11

ground

GND

12

RS485-B signal

RS485-B

13

RS485-A signal

RS485-A

14

ground

GND

15

optocoupler 4 external signal input positive

IO_INPUT4

16

optocoupler 2 external signal input positive

IO_INPUT2

17

Relay 4 output port

OUT_L4

18

Relay 3 output port

OUT_L3

19

Relay 2 output port

OUT_L2

20

Relay 1 output port

OUT_L1

2.4.3 Schematic diagram of USB interface


USB interface application:
1: Application software online upgrade (as shown in figure 2-5 USB interface")
2: USB communications, serial port and network communication all in one (as shown in figure 2-5 USB
communication interface")

Image 2-5 schematic diagram of usb communication port

2.4.4 Description of feeder line(optional)

Image 2-6 schematic diagram of feeder line


RF cable TNC connector connect with reader antenna TNC connector, RF cable SMA connector connect
with external circular polarization antennas SMA connector, cable maximum length is 5m, impedance 50,

insertion loss is less than 2dB, or you also can choose a high performance cable, appropriate increase in
length, insertion loss is less than 2dB.
Note: If Ultra long RF cable or the cable joint is not contacted well, may cause performance deterioration
on the read and write because of the emission signal and the received echo signals attenuation.

2.4.5 Network application connection diagram


Network interface used for long-distance high-speed connection (less than 80 m), can be connected with
the switcher or router through the network cable, or directly connected with the PC network interface, as shown
in figure 2-7:

Image 2-7 Network application connection diagram

3. Installation instructions
3.1 Notes
To ensure the normal and stable operation of the device and your personal property and safety, please
carefully read the following notes before install CL7206C reader and writer:
1. Firstly, check whether the power socket is connected to the ground, and to see whether the local power
supply voltage is in accordance with the applicable voltage range of the reader;
2. Check the device and the external connection if is closely connected;
3. Pay attention to the type selection and the length limit of the cable and the serial line:
Cable connect directly, no longer than 80 meters
Serial line connect directly, no longer than 10 meters
4. When installing several readers, the antenna position and the antenna spacing should be appropriate to
avoid interference with each other.

3.2 Installation conditions


Before installing the reader, please carefully check if the product is in good condition, the accessories are
complete or not, if there is any damage, please contact the supplier.

3.3 Device connection

3.3.1 Connect power adapter


Insert the power cord into the AC power supply socket and plug another end into the power connector of
the device and tighten.
Turn on and wait about 20 seconds, the system initialization process is completed and is standby state.

3.3.2 Connect external antenna and RF cable


The device built with four TNC coaxial cable connector for connecting an external antenna, select low
consumption RF cable, connectors should be tightened (Ensure to be waterproof when install outdoors);

The reader antenna angle or corner to adjust to the best position through the actual test according to the
specific application,.

3.3.3 PC connection
The device provides special adapter cable, including interface of network, serial and power;
RS232 interface is for short distance communication (less than 10m), through the DB9 connector and the
PC serial port connection to realize the communication of PC and the device.
RJ45 network port used for long distance communication (less than 80m), connect PC with extend cable.

3.4 Device installation


The reading and writing range of the reader depends on the onsite application, the tilt angle of the antenna
is adjusted to achieve the best reading and writing performance.

3.5 Acceptance
Mainly from two aspects of acceptance criteria: structure and performance.

3.5.1 Acceptance of structure


If reader is fixed firmly, without loose;
If the cable connected firmly ;
If the screws are tighten

3.5.2 Performance acceptance


If the reader is working properly;
If the read and write range is reasonable.

4. Operating Instruction
4.1 Introduction of Demo software
The demo software mainly carries on system control, communication mode selection, parameter setting
and searching, read and write tags and data presentation and so on.
Before using the demon software, please check if the connection of the reader hardware is completed,
mainly ensure the following tips:
1, If the reader and computer serial port (network or RS485) is connected correctly
2, If the antenna ports have been connected to the antenna (ANT, ANT1 2, ANT 3, ANT totally four ports)
3, If the reader and writer start up (hear "drop" buzzer sound).

4.2 Demo software application environment

The software environment

Windows 2000 Service Pack 3 Windows Server 2003Windows XP Service Pack 2Windows 7 system

The hardware environment

P4/1.7GHz above PC, 512M or more memory, 40GB hard drive

4.3 Demo software version

V1.0.1

4.4 Demo software installation


1. Copy the software to the PC, open the software installation package, double click setup application, follow
the installation guide.
2. Click the next step, and select the installation path, click next, and the software will begin to install.
3. Click the "Install", and software installation progress takes about 1mins.
4. After the progress of the software is finished, click the "finish" button to complete the installation.

4.5 Demo software operation

4.5.1 Connect the reader


All functions can be operated only after successful connection.

4.5.1.1 Serial communication connection

Double click the icon

to start the Demo software, the main interface of the toolbar icons are gray

means reader is not connected, in the connecting reader option list select communication mode serial
connection, connection parameters select COM? (choose PC serial number), communication rate select
115200 (default), click OK button, as shown in image 4-6.

Image 4-6 Serial communication connection


If the connection is successful, all the icons in the toolbar are illuminated, as shown in image 4-7, means
the serial communication connection is successful.

Imag4-7 serial port communication connect successful

4.5.1.2 Network port communication connection


Network port used for long distance connection (within 80 m), connect to the router through cable and
switcher, or connected with the PC network port directly. Select the communication mode "TCP connection" in
the "connect reader" option list, "connect parameter" input reader IP (default 192.168.1.116), enter the
communication port number (default 9090), and click OK button, as shown in image 4-8

Image 4-8 Network port communication connection


The device has been written IP address 192.168.1.116 as default. If you forget or need to modify, using
serial connection "connection" after connect successfully, then you can found the current IP address through

select settings > "senior" > configuration, set up the IP address in Network port settings when
configuration dialog pops up.
Note: The IP address of the reader cant be repeated. Use the Ping command to test whether the network
is connected on PC.

Image 4-4 Settings of reader

4.5.1.3 RS485 communication connection


Select the communication mode in the "connect to the reader" option "485 connection (serial port)",
"connect parameter" select "COM?" (select PC serial number), communication rate select "115200", enter the
RS485 address, then click OK, as shown in image 4-10.

Image 4-10 485 communication connection


RS485 address defaults to 1
RS485 address range 1~255

Note: Click the button

after changing the configuration

4.5.1.4 USB communication connection


Select the communication mode "serial port" in the "connect reader" option list, "connect parameter" select
"COM?" (the USB serial number detected by PC), the communication rate is selected "115200" (the default
value), and click OK button, as shown in image 4-11.

Image 4-11 USB communication connection

4.5.2

Data display area

Click the button

,the data display area will show as image 4-12

Image 4-12 data display area parameter meanings


Type: label type: 6C, 6B two types
EPC: EPC data of tags, can be read and write.
TID: the TID data of the label, the only logo, read only
User Data: user data area, can be read and write.
Reserve Data: reserved area data, store the password data, etc.
Total Count: total number of tags
ANT1: the reading times of NO.1 antenna
ANT2: the reading times of NO.2 antenna
ANT3: the reading times of NO.3 antenna
ANT4: the reading times of NO.4 antenna
RSSISignal Intensity

4.5.2.1 Read EPC

Click the button

, the data display area will display the current read EPC data

EPC display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4 hexadecimal
character)
If you want to read the EPC data of the custom length, please refer to chapter 4.5.2.3 custom read

4.5.2.2 Read TID

Click the button

, the data display area will display the current read EPC and TID data

TID data display as hexadecimal character string, use the word as length unit (1 word = 2 bytes = 4
hexadecimal character).
TID length, the default is 6 words.
If you want to read the TID data of the custom length, please refer to chapter 4.5.2.3 custom read

4.5.2.3 Custom read

Click the button

, pop-up dialog box, as shown in Image 4-13

Select "6C tag configuration"


Matching read, you can matching read through known EPC data or TID data of tags.
Read TID, select to read the tag TID data, the read mode default as "adaptation", use the word as length unit.
Read the user area, select to read the tag user area data, use the word as the starting address and read
length unit
Read the reserved area, select to read the tag retains data, use the word as the starting address and read
length unit

Image 4-13 6C Tag custom configurations


Select the 6B tag configuration, and pop up dialog box as shown in image 4-14
Can choose to read TID data or user data
Can matching read TID data.
Tip: Customer who not familiar with the label agreement, please ignore this feature

Image 4-13 6B Tag custom configurations

4.5.2.4 Stop read

Click button

stop all read and write operations.

4.5.3 Write data

4.5.3.1 Write EPC data

Click button

and pop up dialog box as shown in image 4-15:

Image 4-15 write EPC data


Select a label data (contains TID information) has been read, fill in the EPC data (16 hex string), click "OK".

4.5.3.2 Write user data

Click button

and pop up dialog box as shown in image 4-16:

Image 4-16 write user data

Select a label data (contains TID information)has been read, fill in the user data (16 hex string), click "OK".

4.5.3.3 Custom tag action

Click button

and pop up dialog box as shown in image 4-17:

Image 4-17 Custom tag action


1. Select a tag data that has been read;
2. Click the "custom operation" button;
3. Take detailed action to write / lock / destroy tag according to the reader protocol

4.5.4 TCP server / client mode


Select configuration on the main demo interface > "read and write configuration >" TCP server / client
mode ", pop-up dialog box, as shown in Image 4-18:

Image 4-18 Mode setting


When the reader is configured as a "server" mode, the connection is initiated by PC; when the reader set
as a "client" mode, it will connect to the PC side automatically.

4.5.5 Antenna enable configuration


Select" configuration" on the DEMO main interface-- > "senior"-- > "reader configuration ", then pop-up
dialog box, as shown in image 4-19.

Image 4-19 Antenna enable configuration


Select all antenna enable configuration, click the "configuration", pop up dialog box, click "OK" means

configure succeeds. If the antenna enable is not selected, when select the corresponding reader on the DEMO
main interface, will pop up dialogue box as shown in image 4-20.

Image 4-20 Antenna selection

4.5.6 Base band parameter configuration


Select "configuration" on the DEMO main interface --> "senior" --> "reader", then pop-up dialog box, as
shown in image 4-21.

Image 4-21 Base band parameter configuration


Changing the base band parameter configuration can change the actual effect of the read and write (can be
reasonably configured according to the application scenarios, but it needs to be operated under the guidance
of our engineers).
EPC base band rate provides five options: Tair=25us, FM0, LHF=40KHz, dense reading mode;
Tair=25us, Miller4, LHF=300KHz; fast reading mode; 255/OUTO.
Session four choices: 0; 1; 2; 3.

Q values provide sixteen options: 0/ single label; 1; 2; 3; 4/ multi label; 5; 6; 7; 8; 9; 10; 14; 11; 12; 13; 15.
There are three options for searching tags: one sided search; inventory only with Flag B; double search.

4.5.7 Antenna port power setting


Select "configuration" on the DEMO main interface --> "senior" --> "reader", pop-up dialog box, as shown
in image 4-22.

Image 4-22 Antenna port power setting


Select the corresponding antenna port (external antenna connected), select the appropriate power values
from the power list, click Configure, pop up the configuration of the success of the dialog box, click OK to
complete power configuration.

4.5.8 Clock setting


Select "configuration" on the DEMO main interface --> "senior" --> "reader configuration", then pop-up
dialog box, as shown in image 4-23. The current time of the reader can be check in the area of the reader
time. If you need to modify the reader time, modify the reader time then click configuration button, pop-up
dialog box then click OK.

Image 4-23 Clock display setting

4.5.9 Frequency Hopping management


Click configuration on the main interface > RFID configuration > "hopping management", pop-up
frequency hopping management dialog box, as shown in image 4-24

Imag 4-24 Frequency Hopping management


Select "CMII, 920-925MHz" (see Image 4-25) in the "working band" drop-down list, click the "Settings",
select single frequency points from the left frequency list box(see Image 4-24) then click the "

" button, right

into the list box, and then click the "configuration" to confirm; If you want to select the full band frequency
hopping just click

all the frequency points will show on the right side of the list box, click the

"configuration" to confirm. If you click

, all frequency points on the right side of the list box will be cleared.

Image 4-25 Frequency Band selection


Note: The purpose of setting up the "automatic" is to avoid the interference of the external signal and select the
fast frequency hopping. The default configuration for general application is automatically (as shown red mark
dropdown list in image 4-24).

4.5.10 Label filtering


Select "configuration" on the main interface > "RFID configuration" > "label filter", then pop-up dialog box, as
shown in image 4-26:

Image 4-26 label filtering


Filtering time: indicates that the same label content within a specified period of time within a read card
instruction is only uploaded once, 0~65535, and time units: 10ms.
RSSI threshold: When label RSSI value small than the threshold value, the label data will not be uploaded

and discarded.

4.5.11 Auto idle configuration


Select "configuration" on the main interface > "RFID configuration" > "auto idle ", then pop-up dialog box,
as shown in image 4-27:

Image 4-27 Auto idle configuration


Auto idle mode means when the reader continuous reading tags, all using antenna didnt identify the tags
for three times continuously ,then the reader automatically enter a period of idle state to save power
consumption, the reader re-enter the card reader automatically after idle time.

4.5.12 GPI/O configuration


GPI/O control to provide the query and set up the I/O port state, control the function of the I/O device.
GPI configuration
Select configuration on the main interface > "GPI/O configuration" > GPI configuration "then pop-up dialog
box, as shown in image 4-28:

Imag 4-28 GPI configuration

Check: check the various port trigger parameters

Configuration: select the port need to set, click button to execute the settings after modify

Trigger start condition: select the mode from the drop-down list

Trigger execution instruction: select the mode from the drop-down list

Trigger stop condition: select the mode from the drop-down list

Description: when the start condition is satisfied, the reader will perform the configuration of the reader/
writer command.

GPO configuration
Select configuration on the main interface > "GPI/O configuration" > " GPO configuration "then pop-up
dialog box, as shown in image 4-29:

Image 4-29 GPO configuration

CL7206C reader only supports two GPO outputs, that is "1" and "2".
Select the high / low level, click this configuration to execute settings after modify.

4.5.13 Advanced configuration


Weigand configuration
Select configuration on the main interface > "GPI/O configuration" > Weigand "then pop-up dialog box, as
shown in image 4-30:

Image 4-30 Weigand configuration


In the Weigand parameter settings area, set up the communication switch for the "open" state, and select
the corresponding "communication format" and "transmission data content", click on the "configuration" to
determine.
Weigand port Parameter configuration: includes Weigand 26, Weigand 34" and Weigand 66"models.
Weigand 26: TID or EPC data reported from the end of the Weigand port is valid for 3 bytes.
Weigand 34: TID or EPC data reported from the end of the Weigand port is valid for 4 bytes.
Weigand 66: TID data reported from the end of the Weigand port is valid for 8 bytes.
Restore factory settings
Select configuration on the main interface > restore factory settings then pop-up dialog box, as shown in
image 4-31:

Image 4-31 restore factory settings


When connected to the reader in any form, click OK button, and all settings of the reader will be restored to
the factory setting.

4.5.14 Tools
Data export
Select "tools" on the main interface > "data export" > "form (*. XLS), in the pop-up dialog box, as shown in
image 4-32, select the required export file save path.

Image 4-32 Data export


Read the tag data to support data export, export format can be.Csv (comma file) and.Xls (Excel).
Software upgrade
The reader support for online upgrade, software upgrades support the baseband software upgrade (the

underlying software) and application software upgrades (system software applications). Select "tools" on the
main interface > "software upgrade" > "software", the pop-up dialog box, as shown in image 4-33:

Image 4-33 Application software upgrade


To find the Bin upgrade file path in the upgrade file drop-down list, click

the upgrade

progress bar shows 100% that means the application software upgrade successfully, pop-up upgrade
prompted success dialog box, click OK to restart the reader, as shown in image 4-34.

Image 4-34 Software upgrade successfully


The process of the application of the base band software is the same as that of the application software.

5. Common failures
5.1 Daily maintenance
The routine maintenance of CL7206C usage:
To check whether the tightening of RF connector
To check if the screw fixed reader and antenna is loose
To check whether the RF cable joints appear outsourcing breaking the shielding layer
To check if the reader power line connection is reliable

5.2 Common failure analysis and solution


Power supply system failures:
Check whether the power adapter is normal, and the AC supply voltage is between 100V ~ 240V.
The panel indicator light failed when power on:
Check whether the communication is normal , please contact customer service if its not normal.
The serial port unable to connect:
Check if the serial cable is not connected or connected unstable.
Check if the serial port connect baud rate of the reader is correct
Check if the selected COM port is right.
The network port cannot connect:

Factory set the default IP address: 192.168.1.116 when CL7206C reader device ex-factory, ensure the IP
address of the PC and reader in the same network segment, such as "192.168.1.XXX" then you can connect
to the reader, if you forget the IP address of the device, you can reset the readers IP address through the
serial port.

The reader can't read the tag

Check if the setting of antenna number is correct


Check if the label is damaged
Check if the label is placed in the reader's valid reading and writing range.
Check if the electromagnetic interference between the reader and the other device.
For the problem users cannot solve, please contact customer service.

6. Packing accessories, transportation and storage

6.1 Package

Imag6-1 Carton box size


Carton box size: 362 mm250 mm106mm

6.2 Accessories
In order to facilitate the storage and transportation in near future, the packing box and the packing material
should be kept properly after unpack.
Besides of the device in the box, accessories equipped with the reader are also included in, please check the
product packing list to confirm whether the product and accessories are complete, if any discrepancies or
damage, please contact with the after-sale service in time.
The specific list of accessories as shown in table 6-1

Table 6-1 Package list

NO.

Name

Material Code

Qty

Unit

Remark

set

Included

CL7206C four-port fixed reader

Power adapter 24V/2.5A

20109000000324

pcs

Included

AC power cord

20350000000195

unit

Included

Network cable

20350000000188

unit

Included

RS232 blackcable

20351000000478

pcs

Included

USB cable

20351000000036

pcs

Included

9dBi circularly polarized antenna

20351000000035

pcs

Included

Feeder line SMA-K--TNC-J 50ohm 3m

20351000000038

pcs

Included

Mounting screws M4*28

W01-104028-100

pcs

Included

10

Warranty card

20420000001651

pcs

Included

11

Certificate of approval

20420000001650

pcs

Included

12

CD

N10-010000-002

pcs

Included

6.3 Storage environment


CL7206C fixed reader should be stored in below conditions:
Environment temperature-40+85
Relative humidity5% RH95%RH

7. After-sale service
Letter to Customers
Since our aim is to continuously improve our products for better user experience, we may modify the product
characteristics, composition and design of circuits without given notifications. Thus the real product may be not
in accordance with this manual. Generally, we will provide timely amendments to this manual. If its not
provided timely, please consult our service department.
Shenzhen Clou Electrical Technology Co., Ltd.
Tel of Sales Dept: 0755-36901166-3302
Fax: 0755-26719679
Tel of Customer Service Dept: 0755-36901057
Fax: 0755-26719679

Guarantee card of Shenzhen Electrical Technology Co.,Ltd


Product Name

Model No.

Product Code

Level

Description of
troubles
Users name
Contact person

Postcode
Contact no.

Address of factory: Block 3 of CLOU Electronics Industrial Park, Baolong Industrial City, Longgang
District ,Shenzhen, Guangdong, China (Interchange of Baolong road and Qingfeng Road)
Post code: 518057

Customer service centre: 8009990986

Warranty Description: In order to offer users better service, our company provide warranty card with each
device, please keep it to enjoy the service.
1, Products can replace free under conditions within one month after sale, in the precondition of normal
operation without repairing.
2, Free maintenance wont be given under the following circumstance:
The damage of the terminal caused by high voltage of the power grid.
The damage caused by misuse or operated improperly.
The damage caused by excessive vibration when user delivering.
3, The software of this product can be upgraded freely, users can be training in our company for free.
4, Will be charge appropriately if the user dont have a warranty card.
5, Users will need to fill out the warranty card for repair service, and sent back to CLOU.

Vous aimerez peut-être aussi