Vous êtes sur la page 1sur 1

Calculation for Lighting

21.05.2015

Operator
Telephone
Fax
e-Mail

Ablution / Summary

Height of Room: 3.000 m, Mounting Height: 3.098 m, Light loss factor:


0.90

Values in Lux, Scale 1:20

Surface

[%]

Eav [lx]

Emin [lx]

Emax [lx]

u0

Workplane
Floor

/
20

211
117

158
101

250
129

0.748
0.862

Ceiling
Walls (4)

80
50

42
97

29
31

49
231

0.702
/

Workplane:
Height:
1.000 m
Grid:
32 x 32 Points
Boundary Zone:
0.000 m
Illuminance Quotient (according to LG7): Walls / Working Plane: 0.516, Ceiling / Working Plane: 0.197.
Luminaire Parts List
No.

Pieces

Designation (Correction Factor)

(Luminaire) [lm]

(Lamps) [lm]

P [W]

1350

1350

12.6

1350

12.6

PHILIPS DN570B 1xLED12S/830 C (1.000)


Total:

1350

Total:

Specific connected load: 4.80 W/m = 2.28 W/m/100 lx (Ground area: 2.63 m)