VP37 Eletronic Contorller Oil pump

Calibrating data
1.Cavity pressure
Speed RPM
500
2100
300

Voltage MV

Internal Pressure BAR

2510.0
3330.0
2510.0

8.00
10.70
7.50

MINMUM
7.30
10.00
6.30

MAX.
8.70
11.40
8.70

2.Pistons trip timing


Speed RPM
300
2100

Voltage MV
2510.00
3330.00

travel MM

MIN.

MAX

8.50
12.30

6.00
11.60

11.00
13.00

3. Delivery Oil quantity500 times


Speed RPM
Voltage MV
return oil Temp. Oil Quantity ML Min.
Max.
100
2820.00
60
9.8
8.4
11.2200
400
2000.00
60
6.0
4.2
6.8
800
2650.00
60
18.2
18.1
18.3
500
2510.00
60
19.2
18.4
19.9
1100
2420.00
60
13.6
13.0
14.3
2100
3330.00
60
18.9
18.1
19.6
When test the speed range from 100-400rpm, open the advance angel(timing)
electromagnetic vlave switch button of the tester. when the speed is 100rpm, the oil
quantity count 200 times.

4.Static parameters
Temp.22.5
Between 5 and 6 Resistance
Between 4 and 7 Resistance
Between 1 and 2 Resistance
Between 3 and 2 Resistance

0.7
2.6
7.0
7.0

Minmum
0.4
1.2
6.2
6.2

Max.
1.0
4.0
7.8
7.8

5. Return Oil quantity


Speed 500 Throttle2500 Return oil Temp.60 return oil quantity 50L/H Min30L/H max. 70L/H
Speed 210 Throttle3330 Return oil Temp 60 return oil quantity 60L/H min.40L/H Max.80L/H
L/H is Liter per Hour
Note: All the data is calibrated Based on the pump JB-01,the data will be some
differences based on different testing equipment and testing way. Please calibarte the
data with the standard pumps.

PDF "pdfFactory Pro" www.fineprint.cn

OPERATING INSTRUCTION
1. Technical Data
1. Eletronic Power: 220V 50HZ
2. Output Power: 500 W
3. Data display: Light Four digital Nixietube
4. Control Range: 0-5000rmv
5. Advance angel valve control singal: DC12V 1.5A
6. Block oil valve control singal: DC12V 1.5A
7. Average good runing time: 15000 Hours

2. Button Instructions:

There are total eight buttons, four of them are functions buttons:
( Switch, Export, Angel, and Oil Pump, other four buttons are Meau
Menu, Enter,
1. switch is the key to switch display button. Normally, it show the
actual tooth bar Value, singal lamp power off. Press it, singal lamp
light, it show the Pre-set tooth bar value.
2. export button is the key of controll the output. It can control
voltage while VP37 pump rotating the eletromagnetic iron. Light
effective.
3. angel is switch of the advance angel eletromagnetic vlave.

PDF "pdfFactory Pro" www.fineprint.cn

4. oil pump is the switch of the block oil eletromagnetic vlave.


5. menu can enter or exit the menu setting.
6. enter button is key to confirm, to confirm the parameters are
effective input.
7. is the increase and reduce buttons. It used for changed
the Numerical value .

3. Usage Instructions:
Under the normal situation ( the tester show both the actual tooth bar
value and pre-set tooth bar value) Press or to change the tooth
bar value. After changed the value which is you need, then press
export button, tooth bar can reach the pre-se value.
Press Angel button to open and close the advance angel
eletromagnetic valve. Press Oil pump button to open or close block oil
eletromagnetic valve.

VP37 EDC TESTER

Adaptor A

PDF "pdfFactory Pro" www.fineprint.cn

Power Cable
Note:
VP37 EDC TESTER
Net Weight: divided into two parts
Total net weight is 11kg without the cables and package

PDF "pdfFactory Pro" www.fineprint.cn