Calibrating data
1.Cavity pressure
Speed RPM
500
2100
300
Voltage MV
2510.0
3330.0
2510.0
8.00
10.70
7.50
MINMUM
7.30
10.00
6.30
MAX.
8.70
11.40
8.70
Voltage MV
2510.00
3330.00
travel MM
MIN.
MAX
8.50
12.30
6.00
11.60
11.00
13.00
4.Static parameters
Temp.22.5
Between 5 and 6 Resistance
Between 4 and 7 Resistance
Between 1 and 2 Resistance
Between 3 and 2 Resistance
0.7
2.6
7.0
7.0
Minmum
0.4
1.2
6.2
6.2
Max.
1.0
4.0
7.8
7.8
OPERATING INSTRUCTION
1. Technical Data
1. Eletronic Power: 220V 50HZ
2. Output Power: 500 W
3. Data display: Light Four digital Nixietube
4. Control Range: 0-5000rmv
5. Advance angel valve control singal: DC12V 1.5A
6. Block oil valve control singal: DC12V 1.5A
7. Average good runing time: 15000 Hours
2. Button Instructions:
There are total eight buttons, four of them are functions buttons:
( Switch, Export, Angel, and Oil Pump, other four buttons are Meau
Menu, Enter,
1. switch is the key to switch display button. Normally, it show the
actual tooth bar Value, singal lamp power off. Press it, singal lamp
light, it show the Pre-set tooth bar value.
2. export button is the key of controll the output. It can control
voltage while VP37 pump rotating the eletromagnetic iron. Light
effective.
3. angel is switch of the advance angel eletromagnetic vlave.
3. Usage Instructions:
Under the normal situation ( the tester show both the actual tooth bar
value and pre-set tooth bar value) Press or to change the tooth
bar value. After changed the value which is you need, then press
export button, tooth bar can reach the pre-se value.
Press Angel button to open and close the advance angel
eletromagnetic valve. Press Oil pump button to open or close block oil
eletromagnetic valve.
Adaptor A
Power Cable
Note:
VP37 EDC TESTER
Net Weight: divided into two parts
Total net weight is 11kg without the cables and package