Académique Documents
Professionnel Documents
Culture Documents
Type:
RIMOUSTT
Item no.:
0067751.001
Dimensional drawing
Front view
Side view
Assembly
Dimensions in mm
Subject to change
Page 1/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar
RIMOUSTT
Application
In combination with the Instrumentation Controller the RISONIC ultrasonic transit time module (RIMOUSTT)
is designed to perform ultrasonic flow measurements in pipes and channels. The system measures the path
velocity (v), and, from that, calculates the flow rate per time unit (Q) and the volume (V).
Brief description
An Instrumentation Controller can be operated with up to 5 RISONIC ultrasonic transit time modules
(RIMOUSTT). Depending on the hydraulic measuring conditions, the measuring paths can be configured in a
variety of measuring arrangements.
This module can be operated with all RISONIC 2000 and various retrofit sensors (200 kHz, 500 kHz, 1 MHz).
Subject to change
Page 2/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar
RIMOUSTT
Specifications
Overview
Galvanically
isolated, reverse
voltage protection,
EMI filter
24VDC IN
+ -
Galvanically
isolated
Galvanically
isolated
Galvanically
isolated
Galvanically
isolated
Galvanically
isolated
DO 1
DO 2
DO 3
DO 4
NC NO COM
NC NO COM
NC NO COM
NC NO COM
Galvanically
isolated
AO
+ -
AI
+ -
Status LED
Reset
button
Mode rotary
switch
ID rotary
switch
LAN2 Ethernet
10BaseT
PATH LEDs
PATH A
PATH B
PATH C
PATH D
Ground
Subject to change
Page 3/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar
RIMOUSTT
Setup
Power supply
Polarity:
Torque of connector screws:
Power consumption:
Galvanic isolation:
Displays
LEDs
Status
Red:
Red flashing:
Green:
DO 1 4
Green:
PATH A D
Red:
Orange:
Green:
Controls
Rotary switch
Recessed key
Mode:
Operating mode
ID:
Reset:
Reboot
Activates/deactivates a 50 Hz/60 Hz notch filter for the analog
input (mains suppression filter, damping min. 110 dB)
Inputs / outputs:
24 VDC IN
R1 R8
AI
Subject to change
Page 4/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar
RIMOUSTT
AO
DO 1 4
EARTH
Ground connector, 16 mm / M6
Data interfaces
LAN2
Environmental conditions
Installation site:
-20+70 C
-40+85 C
5-95% @25 C, non condensing, decreasing linearly to
40% relative humidity at 40 C
Protected from direct sunlight, vibrations and mechanical shock,
max. altitude 5000 m
Quality tests
The device meets the requirements for CE certification according to:
EN 61000-6-3:2007
EN 61000-6-2:2005
EN 60950-1:2006+A11:2009
EN 60950-22:2006
EN 60068-2-38:2009
WEEE
QUYX
Online certificate:
Subject to change
Page 5/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar
RIMOUSTT
QUYX7
Online certificate:
Parameter configuration
Parameters cannot be configured directly on device; can only be used in connection with an Instrumentation
Controller (RICTRL).
Electrical connections
Supplied accessories
Optional accessories
See Instrumentation Controller 21.210.0067760.xxx data sheet.
Subject to change
Page 6/6
DG
DKap
Stamm-Bez.
Var
Ind
F Sp
22.210.0067751.001.04.4.4
2013 by Rittmeyer AG, CH-6341 Baar