V. Palchik and Y. H. Hatzor

Rock Mech. Rock Engng. (2004) 37 (4), 331341


DOI 10.1007/s00603-003-0020-1

Nota tecnica
The Influence of Porosity on Tensile and Compressive
Strength of Porous
Chalks
La influencia de la porosidad en traccin y compresin
Fuerza de la porosos Tizas
By

V. Palchik and Y. H. Hatzor


Department of Geological and Environmental Sciences, BenGurion University
of the Negev, Beer-Sheva, Israel
Received April 3, 2003; accepted September 19, 2003
Published online February 18, 2004 # Springer-Verlag 2004

Keywords: Point load strength, Brazilian strength, uniaxial compressive strength, porosity, chalks.

1. Introduction
La resistencia a la compresin ya la traccin de las rocas son importantes parmetros de
diseo de ingeniera de rocas. La resistencia a la compresin uniaxial se puede obtener a
travs de la correlacin con el ndice de punto de resistencia de carga (D'Andrea et al,
1965;. Broch y Franklin, 1972; Pells,
1975; Hassani et al., 1980; Haramy et al., 1981; Kahraman, 2001). En rocas muy porosas
Sin embargo, la porosidad se ha demostrado para controlar el comportamiento mecnico
(por ejemplo, Dunn et al, 1973;. Hoshino, 1974; Dearman et al, 1978;. Jatzor y Palchik,
1998; Palchik,
1999; Al-Harthi et al., 1999; Palchik y Jatzor, 2002). tizas porosos son bastante
heterogneos (Bowden et al, 1998;.. Bell et al, 1999; Risnes, 2001) y, por tanto, la
resistencia a la rotura y deformacin tpicamente cambio dentro de la misma formacin.
El objetivo de este trabajo es determinar la resistencia uniaxial a la compresin, resistencia
a la carga puntual, y traccin indirecta (brasileo) fuerza de una tiza muy porosa formacin
cin - la Formacin Adulam en Israel (n = 18-44%), y estudiar cmo porosidad influye en
la magnitud de y la relacin entre estas propiedades mecnicas. Los resultados obtenidos
se comparan con los mtodos ISRM sugerido (ISRM, 1985) para determinar la resistencia
a la carga puntual.
2. Experimental Procedures and Results
Procedimientos y resultados experimentales
Las muestras para la compresin uniaxial se molieron superficie con una rugosidad menor
que 0,01 mm; espcimen termina de carga puntual, pruebas y mediciones de porosidad
brasileos eran

332

V. Palchik and Y. H. Hatzor

Fig. 1. The relationship between specimen axis, bedding plane direction, and loading direction: a uniaxial
compression test; b point load test and indirect tension (Brazilian) test
La relacin entre el eje del espcimen, la direccin del plano de estratificacin, y direccin de carga: un
ensayo de compresin uniaxial; prueba de carga punto B y la tensin indirecta (brasileo)

de tierra a una rugosidad de hasta 0,25 mm. perpendicularidad Cilindro de todos los
especmenes estudiados fue de 0,05 radianes. Todas las muestras se quit el corazn de
tal manera que su eje fue paralela a la ropa de cama (ver Fig. 1). Todas las muestras se
sec en estufa a una temperatura de 110 C durante 24 h.
2.1 Uniaxial Compressive Strength
Resistencia a la compresin uniaxial
Twelve compression tests were performed on 52 mm diameter cylindrical specimens
with length=diameter ratio of approximately 2.0 (Fig. 1a). A stiff load frame
Doce ensayos de compresin se realizaron en probetas cilndricas de dimetro 52 mm
con relacin longitud = dimetro de aproximadamente 2.0 (Fig. 1a). Un bastidor rgido

Influence of Porosity

333

Table 1. Results of uniaxial compression tests and porosity calculations for 12 specimens of 52 mm diameter
Sample

E, MPa

RC1
RC2
RC3
RC4
RC6
RC7
RC8
RC9
ST1A
ST1B
ST2A
ST2B

17400
9300
16000
11700
19250
9500
17300
20500
16200
15400
14300
10700

c,

0.23
0.2
0.26
0.2
0.26
0.21
0.2
0.27
0.31
0.23
0.2
0.22

MPa

53.2
20.9
51
31.9
63.3
32.9
60.3
63.1
50.9
53.7
52.25
37.4

d,

g=cm3

2.12
1.85
2.07
1.93
2.14
1.89
2.11
2.17
2.15
2.16
2.14
2.06

n, %
21.5
31.5
23.3
28.5
20.7
30
21.9
19.6
20.5
20.2
20.7
23.7

E el mdulo de elasticidad, coeficiente de Poisson, c uniaxial resistencia a la compresin, densidad


aparente seca d, n porosidad calculada (at Gs 2:7:

332 (Terra-Tek, modelo FX-S-33090) fue utilizado que utiliza un bucle cerrado, servo
sistema hidrulico controlado con fuerza axial mxima de 1,4 MN y la rigidez de
5 109 N = m (para obtener detalles del bastidor de carga se refieren a Jatzor y Palchik,
1997). Los resultados de la
ensayos de compresin uniaxial se presentan en la Tabla 1.
Dos cepas radiales se midieron en direcciones ortogonales en un plano normal al eje de la
muestra (ver Figs. 1a y 3a). Una comparacin entre las salidas de tensin radial "r1 y la
tensin radial" r2 para las 12 muestras analizadas bajo compresin uniaxial se representa

Fig. 2. Comparison between radial strains "r1 and "r2 for 12 specimens tested under uniaxial compression
La comparacin entre las cepas radiales "r1 y" r2 para 12 muestras analizadas bajo compresin uniaxial

Fig. 3. Test assemblies: a for uniaxial compression test; b for point load test; c for indirect tension
(Brazilian) test
Tes montajes: una para el ensayo de compresin uniaxial; b para la prueba de carga puntual; c para la tensin
indirecta

V. Palchik and Y. H. Hatzor: Influence of Porosity

335

en la Fig. 2. Las regresiones lineales obtenidos entre "r1 y" r2 son buenos (R2
0,95-0,99). Los smbolos reflejan medidas de deformacin radial obtuvieron a partir de 0
a carga
el lmite elstico de la curva tensin-deformacin. Considere ngulo, definido aqu como
el ngulo medido en un plano normal al espcimen eje, entre la traza de plano de
estratificacin y el eje de "R1 (vanse las figuras 1a y 2). En nuestras pruebas el ngulo
vari de 0 a 90 -. A saber, no hemos intento de alinear el "eje r1 con la direccin plano de
estratificacin. Sin embargo, la salida de los dos transductores de deformacin radial fue
casi idntico en todos menos en un caso (outlier) (muestra ST1A). Espcimen ST1A tena
grietas iniciales o venas que probablemente distorsionado la distribucin de la
deformacin radial bajo la carga aplicada. El valor calculado de la pendiente media es de
1,02 con una pequea desviacin estndar de 0,1, por lo tanto, podemos establecer que las
cepas radiales medidas en direcciones ortogonales son idnticos. Este resultado sugiere
isotropa transversal en un plano normal a la ropa de cama (o con la muestra en el eje).
2.2 Point Load Strength
La fuerza del punto de carga
Dieciocho muestras cilndricas de 52 mm de dimetro fueron preparados para las pruebas de
carga punto diametral con relacin longitud = dimetro superior a 1,0 (Fig. 1b). pruebas de
carga puntual se realiz con un punto de carga estndar = probador uniaxial (modelo SBEL
PLT-75). Un diagrama esquemtico del conjunto de prueba de carga puntual se presenta en
la Fig. 3b. Los resultados del ensayo se presentan en la Tabla 2.
2.3 Indirect Tensile (Brazilian) Strength
2.3 Resistencia a la traccin indirecta
(brasileo)
Veinte especmenes cilndricos de dimetro 52 mm se prepararon para los ensayos brasileos. El espesor de la
muestra fue de aproximadamente igual al radio de muestras (Fig. 1b). traccin indirecta de fuerza (brasileo) se
obtuvo usando la misma carga Point = uniaxial
Table 2. Results of point load tests and porosity calculations for 18 specimens
of 52 mm diameter
Los resultados de las pruebas de carga de punto y los clculos de porosidad de
18 muestras de 52 mm de dimetro
Sample
PL1
PL2
PL3
PL4
PL5
PL6
PLA1
PLA2
PLA3
PLB1
PLB2
P1
P2
P3
P4
P5
P6
P7
d

d,

g=cm3

1.89
2.1
2.18
2.09
1.93
1.76
1.84
1.78
1.76
1.65
1.7
2.09
1.67
2.06
2.05
2.19
1.93
1.73

n, %

Id , MPa

29.9
22.2
19.1
22.6
28.7
35
32
34.2
35
39
37
22.5
38.3
23.6
23.9
18.9
28.6
36

2.86
3.54
4.28
3.25
2.58
1.85
2.31
1.72
1.83
1.69
1.78
3.11
2.27
2.82
2.97
3.37
2.98
1.84

dry bulk density, n calculated porosity (at Gs 2:7), Id point strength.

336

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

336

Table 3. Results of Brazilian tests and porosity calculations for 20 specimens


of 52 mm diameter
Sample
BT1
BT2
BT3
BT4
BT5
BT6
BLA1
BLA2
BLA3
BLB1
BLB2
BLB3
B1
B2
B3
B4
B5
B6
B7
B8

d,

g=cm3

2
2.06
2.04
1.86
1.93
1.87
1.65
1.52
1.92
2.02
2.13
1.86
1.68
1.76
1.53
2.03
1.91
1.7
1.69
2.06

n, %

t,

26.1
23.6
24.4
31
28.4
30.7
38.9
43.9
28.7
25.3
21.2
31.1
37.6
35
43.4
24.7
29.4
37.2
37.6
23.8

d dry bulk density, n calculated porosity (at Gs 2:7),


(Brazilian) strength.

MPa

7.49
8.58
5.49
4.47
3.59
4.36
5.17
2.85
6.9
8.01
8.74
6.35
3.9
4.4
2.5
5.6
5.04
4.96
2.92
6.48
t

tensile

SBEL Tester (model PLT-75). Here however, loading was applied by two diametricallyopposed concave loading jaws (Fig. 3c). Since the isotropy of the studied chalk in a plane
normal to bedding was confirmed in the uniaxial tests discussed above, there was no need
to align the conical platens or loading jaws with the trace of bedding planes in point load or
Brazilian tests, respectively. Indirect tensile strength results t are presented in Table 3.

3. Porosity
3.1 Porosity Calculation
The porosity of 50 dry specimens from Tables 13 was calculated prior to mechanical
testing. The porosity (n) of the solid-cylinder chalk specimens was obtained by the
expression n 1
d =Gs w 100% using measured values of dry bulk density
( d , g=cm3), water density w 1g=cm3, and assumed specific gravity of Gs 2:7
which is typical for calcite. The Gs assumption was validated using porosimeter
measurements (Section 3.2 below). The calculated porosity values ranged between
18% and 44%. The precision of the calculated values is to be within 0.1%. Bulk density
and porosity values for all 50 specimens are presented in Tables 13.

3.2 Porosity Measurement


A Helium porosimeter (CoreTest Inc., model PHI-220) was used to confirm the
validity of the porosity estimations. In order to determine the porosity of the studied

337

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

337

Table 4. Bulk volume, dry bulk density, grain volume observed in Helium porosimeter PHI-220, and
calculated porosity of 10 specimens (diameter of 25.4 and 38 mm)
. volumen de la masa, densidad aparente en seco, el volumen de grano observada en helio porosmetro PHI220, y la porosidad calculada de 10 especmenes (dimetro de 25,4 mm y 38)
Sample

Vbulk , cm3

PS1(25.4)
PS2(25.4)
PS3(25.4)
PS4(25.4)
PS5(25.4)
PS6(25.4)
PS7(25.4)
PS8(25.4)
PM1(38)
PM3(38)

11.43
10.87
11.55
11.61
11.78
11.95
12
11.82
40.9
41

d,

g=cm3

2.13
2.13
2.13
1.72
1.9
2
1.83
1.96
2.28
2.26

Vgrain , cm

nporosim , %

n, %

9.09
8.68
9.13
7.65
8.37
8.93
8.17
8.64
34.9
34.3

20.4
20.1
21
34.1
29
25.3
31.9
27
14.7
16.3

21.2
21.1
21.2
36.1
29.8
26
32.4
27.3
15.6
16.3

(25.4) and (38) specimen diameter in mm, Vbulk bulk volume, d bulk dry density, Vgrain grain volume,
nporosim porosity observed using Helium porosimeter, n calculated porosity (at Gs 2:7).

tizas, ocho especmenes de dimetro 25,4 mm y dos ejemplares de dimetro 38 mm con una
longitud de 25,4 y 38 mm, respectivamente, se examinaron. La determinacin del volumen
de poros no se realiz por medicin directa porque la medicin directa del volumen de poros
requiere la determinacin anterior de la llamada '' volumen muerto '' en el porosmetro. La
medicin de la '' volumen muerto '' requiere un aparato adicional (un coreholder) que no fue
utilizado en esta investigacin. Por lo tanto, se utiliz el porosmetro para determinar el
volumen de grano, y luego se calcul el volumen de poros mediante el volumen midieron
la mayor (con 10 pinzas de resolucin de micrmetro) y el volumen de grano medido
(utilizando el porosmetro). La porosidad obtenida se denomina porosidad 'medido' a
continuacin.
Resultados de volumen a granel Vbulk , densidad aparente d d seca, el volumen de
grano Vgrain ,
'Medido' porosidad nporosim Th, y la porosidad calculada (n, con Gs 2: 7), para todos
especificado
mens probados en el porosmetro de helio se presentan en la Tabla 4. Como una muy buena
correlacin lineal DR2 0: 99 o se encuentra entre la porosidad calculada y 'medido'
valores, llegamos a la conclusin de que la asuncin de Gs 2: 7 se justifica por las tizas
estudiados.
4. Discussion
4.1 Point Load and Brazilian Strength
CARGA PUNTUAL y fuerza brasilea
El efecto de la porosidad de la fuerza de carga puntual hizo Th y resistencia a la traccin D
t brasilea se presenta en la Fig. 4a de la que pueda inferirse tres tendencias:
1. Tanto los ndices de carga y punto de resistencia de Brasil estn inversamente
relacionados con la porosidad.
2. La correlacin entre la porosidad y la carga de punto de fuerza es bueno: la fuerza de
carga puntual disminuye rpidamente al aumentar la porosidad. La relacin sigue una ley
exponencial con un coeficiente de regresin cuadrado razonable DR2 0 84 o que puede
ser descrita por:
Id ce

dn

where c and d are empirical coefficients which for Adulam chalks are: c 7:74,
d 0:039.

338

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

338

Fig. 4. Influence of porosity on mechanical strength: a point load strength Id and Brazilian strength t ; b
uniaxial compressive strength c

3. La correlacin entre D fuerza brasilea T y la porosidad es algo ms dbil DR2 0:


66. Por lo tanto, un modelo matemtico para esta dependencia no se sugiere aqu,
aunque existe claramente una tendencia. Del mismo modo, un modelo explcito de Id = t
fn no se sugiere aqu.

339

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

339

4.2 Uniaxial Compression


La relacin entre la resistencia a la compresin uniaxial y la porosidad se muestra en la
Fig. 4b, que muestra los resultados de los 12 ensayos de compresin uniaxial. Una
buena correlacin se obtiene que sigue una ley exponencial DR2 0: 87: c ae bn
2
donde a y b son coeficientes empricos que para tizas Adulam son: a 273: 15,
b 0: 076.
4.3 The Ratio Between Uniaxial and Point
Load Strength c =Id
La relacin entre uniaxial y punto
Fuerza de carga
The point load test may be used as an index property in rock engineering applications
where in fact the true uniaxial compressive strength is sought. This is because obtaining point load strength data is by far simpler than obtaining actual uniaxial compression test data, which requires strict adherence to sample preparation standards and
sophisticated testing techniques. Therefore, it has become standard practice to rely on
published correlations for predicting uniaxial strength from point load data. For
50 mm diameter core samples the typical correlation is: c =Id 2025 (ISRM,
1985).
En esta seccin se explora el papel de la porosidad y cmo influye en la correlacin
entre el punto de carga y resistencia a la compresin uniaxial. En la ecuacin. (1) se le
dio la influencia de la porosidad en ndice de carga y el punto en la ecuacin. (2) la
influencia de la porosidad en

Fig. 5. Calculated effect of porosity on the ratio between uniaxial compressive strength and point load
strength, for studied chalks
efecto de la porosidad calculada de la relacin entre resistencia a la compresin uniaxial y la fuerza de carga
puntual, para tizas estudiados

340

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

340

Se describi la verdadera resistencia a la compresin uniaxial. Utilizando la


ecuacin. (1) y la Ec. (2) se puede escribir una nueva expresin para la relacin
entre la compresin uniaxial y la fuerza de carga puntual, como una funcin de
la porosidad:
true uniaxial compressive strength was described. Using Eq. (1) and Eq. (2) we can write
a new expression for the ratio between uniaxial compressive and point load strength, as a
function of porosity:
c

Id

k1 e

k2 n

donde k1 y k2 son coeficientes empricos que pueden ser calculados a partir de los
coeficientes
a, b, c y d: k1 a = c 35: 3, k2 b d 0: 037.
La relacin emprica sugiere en la ecuacin. (3) se representa en la Fig. 5, donde es
muestra que la relacin c = Id disminuye exponencialmente 18-8 con el aumento de los
valores de porosidad (n) de 18% a 40%. Por lo tanto, un aumento de la porosidad en un
factor de
2.2 conduce a una disminucin en la relacin c = Id por un factor de 2,25.
Podemos concluir por lo tanto que la relacin entre resistencia a la compresin uniaxial
y la fuerza de carga punto dentro de la misma formacin tiza heterognea puede no ser
constante, pero es la porosidad dependiente. Adems, puede deducirse de la fig. 5 que ms
dbiles (mayor porosidad) tizas tienen una baja relacin c = Id, mientras que tizas ms
fuertes (ms baja porosidad) tienen una mayor relacin c = Id.
5. Conclusions
intensidad en el punto de carga, indirecta resistencia a la traccin (brasileo), resistencia
a la compresin uniaxial y la porosidad de Adulam tiza en Israel se estudiaron utilizando
muestras cilndricas secos con la misma orientacin (espcimen eje paralelo a la ropa de
cama). La validez del clculo porosidad se confirm mediante la medicin de volumen de
grano usando un porosmetro de helio.
Se estableci que la fuerza de carga puntual y resistencia a la compresin uniaxial en
tizas Adulam porosos disminuyen al aumentar la porosidad, mientras que el mismo efecto
de la porosidad en resistencia a la traccin de Brasil estaba presente pero no significativo.
Se proponen dos modelos exponenciales relativas a la porosidad fortalezas de carga
uniaxial o puntuales.
Nuestras observaciones tambin muestran que la relacin c = Id entre resistencia a la
compresin uniaxial y la fuerza de carga punto no es constante (intervalo 8-18), pero es la
porosidad dependiente. Un aumento en la porosidad de 18 a 40% conduce a una
disminucin en c = Id de 18 a 8. La diferencia entre la relacin observada (8-18) y la
prctica estndar (c = Id 20-25), segn el mtodo sugerido ISRM ( ISRM, 1985) puede
ser tan alta como 127%.
References
Al-Harthi, A. A., Al-Amri, R. M., Shehata, W. M. (1999): The porosity and engineering properties
of vesicular basalt in Saudi Arabia. Engng. Geol. 54, 313320.
Bell, F. G., Culshaw, M. G., Cripps, J. C. (1999): A review of selected engineering geological
characteristics of English chalk. Engng. Geol. 54(34), 237269.
Bowden, A. J., Lamont-Black, J., Ullyott, S. (1998): Point load testing of weak rocks with
particular reference to chalk. Quarterly J. Engng. Geol. 31(2), 95103.
Broch, E., Franklin, J. A. (1972): The point-load strength test. Int. J. Rock Mech. Sci. 9, 66

341

V.Influence
Palchik and
of Porosity
Y. H. Hatzor

341

Vous aimerez peut-être aussi