Vous êtes sur la page 1sur 39

Products for flow measurement - Ultrasonic flowmeters

Flexible measurement from outside the pipe without process interruption

All

Conductive Liquids

Non-conductive Liquids

General
Transmitters

Sensors

General
Ultrasonic transit-time differential measurement can be employed to measure the volume flow of any liquid, regardless of
electrical conductivity. Two different types of sensors enable users to meter flow cost-effectively, economically and
flexibly, anywhere in the process and at any time: clamp-on sensors and inline sensors.

Transmitters

The transmitters are available as wall-mount or field housings for hazardous areas and for the process industry. These
meters integrate easily into higher-order process-control systems and support the mainstream Fieldbus systems. The
choice of transmitter depends on process requirements and on the type of sensor.

Prosonic Flow 90
For standard applications
For clamp-on and insertion sensors
Two-line, backlit display
Pushbutton controls
With PROFIBUS PA
Prosonic Flow 91
For basic applications
For clamp-on sensors
Two-line display
Pushbuton controls
With current output (HART) and PROFIBUS PA
Prosonic Flow 92
Two-wire transmitter
For Prosonic Flow F sensor
Remote or compact version
Suitable for hazardous areas (Ex i, Ex d)
Two-line display
Pushbutton controls
With current output (HART), pulse and status
output
Prosonic Flow 93
For extended functionality in process applications
and hazardous areas (incl. Fieldbus
communications)

For clamp-on, insertion or inline sensors


Four-line, backlit display
Touch Control operation from outside
For registering flow at two measuring points or with
two ultrasonic paths (two-channel measurement)
F-CHIP for software options
Prosonic Flow 92T
Portable ultrasonic transmitter for temporary metering
For all clamp-on sensors
With integrated data logger
For monitoring processes and for test measurements (e.g. leak tests)
Large, backlit display (with graphics capability)
Quick Setup for easy operation

Sensors

The range of sensors is extensive, so widely differing sets of requirements can besatisfied. Clamp-on sensors retrofit to
the outside of existing pipes, e.g. for verifying other meters or for temporary flow measurement (accuracy: typically 2%
o.r.). Inline sensors for direct installation in the pipe meet higher accuracy requirements (0.3 to 0.5% o.r.).
Prosonic Flow W (clamp-on)
For measuring from outside
For standard applications
-20...+130 C (-5...+260 F)
For diameters DN 50...4000 (2...160")
Prosonic Flow P (clamp-on)
For measuring from outside
For industrial process applications,
-40...+170 C (-40...+340 F)
Ex-approvals
For diameters DN 50...4000 (2...160")
Prosonic Flow U (clamp-on)
For measuring from outside
For the pharmaceuticals and semiconductor
industries,
-20...+80 C (-5...+180 F)
For small diameters
DN 15...100 (1/2...4")
Prosonic Flow W (insertion)
For sonically non-conductive pipes
For water/wastewater applications,
-20...+80 C (-5...+180 F)
For diameters DN 200...4000
(8...160")
Optional as two-path version for short inlet runs
Prosonic Flow C (in-line)

For guaranteed accuracy


For water/wastewater applications, up to +60 C
(+140 F)
Nominal Diameters
DN 300...2000 (12...80")
EN (DIN), ANSI and AWWA process connections
Guaranteed, traceable accuracy (0.5% o.r) by
factory calibration
Cost-effective alternative to large magmeters
With approval for potable water
Prosonic Flow F (in-line)
For guaranteed accuracy
For all liquids, e.g. in the chemical and
petrochemical industries, -40 to +150 C (-40...300
F)
Nominal diameters: DN 25 to 150 (1...6")
EN (DIN), ANSI process connections
Traceable accuracy (0.3 to 0.5% o.r.) by factory
calibration
For limited space (inlet run only 5 DN)

Prosonic Flow Clamp On 90P


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Volume flow measurement of liquids in chemical or process applications
Your benefits
Prosonic Flow clamp-on is the flexible and cost-effective flow measuring system.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process

Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
Approvals for hazardous area:
ATEX, FM, CSA
Connection to process control system:
HART, PROFIBUS PA
Order information

Prosonic Flow Clamp On 90P


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA
Print this page

Recommend this page

Technical data
Conductive Liquids
Non Conductive Liquids

Bookmark this page

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water, waste water and
process water.
DN 50...4000
2"...160"
0...678'550 m3/h
-40...+170C / -40...+338F
No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x
Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurement from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection type
Sensor in IP 67 / IP 68 protection type
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting

Prosonic Flow Clamp On 90P


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process

Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water, waste water and
process water.
DN 50...4000
2"...160"
0...678'550 m3/h
-40...+170C / -40...+338F
No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x
Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurement from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection type
Sensor in IP 67 / IP 68 protection type
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting

Prosonic Flow Clamp On 90U


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a clamp-on
unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
Connection to process control system:
HART, PROFIBUS PA

Prosonic Flow Clamp On 90U


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
HART, PROFIBUS PA
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication

Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with small pipe sizes.
DN 15...100
1/2"...4"
0...424 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x
Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurement from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection type
Sensor in IP 54 protection type
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting

Prosonic Flow Clamp On 90U


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
HART, PROFIBUS PA
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic

Ultrasonic
Flow volume measurement from outside for standard
applications with small pipe sizes.
DN 15...100
1/2"...4"
0...424 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x

Features

Advantages

Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurment from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection
Sensor in IP 54
"Quick Setup" menus for straightforward
commissioning
Easy and cost-effective mounting

Prosonic Flow Clamp On 90W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a clamp-on
or insertion unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
Connection to process control system:
HART, PROFIBUS PA

Prosonic Flow Clamp On 90W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
HART, PROFIBUS PA
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water, waste water and
process water.
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176 F

Pressure range
Measured error
Display/Operation

No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x
Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurement from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection type
Sensor in IP 67 / IP 68 protection type
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting

Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Advantages

Prosonic Flow Clamp On 90W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
HART, PROFIBUS PA
Print this page

Recommend this page

Technical data
Conductive Liquids
Non Conductive Liquids

Bookmark this page

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water, waste water and
process water.
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176 F
No limit
+/-2.0 %
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
Profibus PA
FM
CSA
IP67
NEMA 4x
Validation
Quick Set-Up
2 Totalizers
Sonic speed output
Non-invasive measurement from outside "Clamp On"
Transmitter 90 in protected wall-mount housing in IP
67 protection type
Sensor in IP 67 / IP 68 protection type
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting

Prosonic Flow Clamp On 91W


General
Technical
information
information
Product Picture

Product description
Field of application
Order information
Product description

Documents/
Software

Service

Accessories/
Spare parts

Successor

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a clamp-on
unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
Connection to process control system:
HART

Prosonic Flow Clamp On 91W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining

For water/wastewater applications


Ideal for retrofitting
Installation without process interruption
HART
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Ultrasonic
Flow Volume measurement from outside for standard
applicationswith drinking water, waste water and
process water
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0%
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
FM
CSA
IP67
NEMA 4x
Validation
Sensor Set-Up

Prosonic Flow Clamp On 91W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations

No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
HART
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Ex-Approvals
Protection electronic
Features

Ultrasonic
Flow Volume measurement from outside for standard
applicationswith drinking water, waste water and
process water
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0%
Two line backlit
Push buttons
Status
4...20mA
Pulse/Frequency/Status
HART
FM
CSA
IP67
NEMA 4x
Validation
Sensor Set-Up

Prosonic Flow Inline 92F


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


2-Wire loop powered inline flowmeter
Your benefits
The calibrated Inline version Prosonic Flow 92F is for measuring flow of conductive and
especially non-conductive liquids such as solvents and hydrocarbons.
The Proline transmitter concept comprises of:
Modular device and operating concept resulting in a higher degree of efficiency
Diagnostic ability and data back-up capability for increased process quality
Permanent self-monitoring and diagnosis of transmitter and sensor
The Proline Prosonic Flow sensors comprises:
Available as a 2, 3 or 4 beam version
New innovative loop powered three/fourbeam design facilitates a reduced requirement for
upstream pipework ( 5 pipe diameter)
Calibration traceable to international standards
No pressure drop
Maintenance free due to no moving parts
Field of application

The flowmeter is ideally suited for applications in process control and utility measurement in
practically all sectors of industry such as the chemical and petrochemical industry, energy
production and district heating.
Loop powered transmitter (2-Wire)
Accuracy up to 0.3% (optional)
Fluid temperatures up to 150 C (302 F)
Process pressures up to 40 bar (580 psi)
Galvanically isolated pulse output available
Approvals for hazardous area:
ATEX, FM, CSA
Connection to common process control systems:
HART, PROFIBUS PA
Relevant safety aspects:
Pressure Equipment Directive (PED)

Prosonic Flow Inline 92F


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up capability for increased process quality
Permanent self-monitoring and diagnosis of transmitter and sensor
Available as a 2, 3 or 4 beam version
New innovative loop powered three/fourbeam design facilitates a reduced requirement for
upstream pipework ( 5 pipe diameter)
Calibration traceable to international standards
No pressure drop
Maintenance free due to no moving parts
Loop powered transmitter (2-Wire)
Accuracy up to 0.3% (optional)
Fluid temperatures up to 150 C (302 F)
Process pressures up to 40 bar (580 psi)
Galvanically isolated pulse output available
ATEX, FM, CSA
HART, PROFIBUS PA
Pressure Equipment Directive (PED)
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error

Display/Operation
Outputs

Communication

Ultrasonic
The ideal flow solution for electrical non conductive
and conductive liquids. Ultrasonic transit time
method, loop powered, multibeam flowmeter (2,3 and
4 beams)Available as 2, 3 or 4 beam version.
DN 25...150
1"...6"
0...600 m3/h, 0...2650 gal/min
-40...150C / -40...300F
PN 40
Cl 150
+/- 0.5% o.r. +/- 0.01% o.f.s. for v > 0.5 m/s (optional
0.3% o.r.)
+/- 0.035% o.f.s. for v<0.5 m/s)
Reynolds number > 10.000
Two line backlit
Touch control
4...20mA
Impulse
Status
HART
Profibus PA

Ex-Approvals

Protection electronic
Features

Advantages

ATEX
FM
CSA
TIIS(In Preparation)
IP67
NEMA 4X
Loop powered
Multibeam
Non-invasive sensors
All stainless steel design
Compact and remote version
Safe and easy system integration
Short straight inlet requirements (5 x DN)
Non invasive
No internal process seals all welded design
Energy saving due to low power consuption
No pressure drop

Prosonic Flow Inline 92F


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up capability for increased process quality
Permanent self-monitoring and diagnosis of transmitter and sensor
Available as a 2, 3 or 4 beam version
New innovative loop powered three/fourbeam design facilitates a reduced requirement for
upstream pipework ( 5 pipe diameter)
Calibration traceable to international standards
No pressure drop
Maintenance free due to no moving parts
Loop powered transmitter (2-Wire)
Accuracy up to 0.3% (optional)
Fluid temperatures up to 150 C (302 F)
Process pressures up to 40 bar (580 psi)
Galvanically isolated pulse output available
ATEX, FM, CSA
HART, PROFIBUS PA
Pressure Equipment Directive (PED)
Print this page
Technical data

Recommend this page

Bookmark this page

Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Diameter
Measuring range
Process temperature
Pressure range
Measured error

Display/Operation
Outputs

Communication
Ex-Approvals

Protection electronic
Features

Advantages

Ultrasonic
The ideal flow solution for electrical non - conductive
and conductive liquids. Ultrasonic transit time
method, loop powered, multibeam flowmeter (2,3 and
4 beams)
DN 25...150
1"...6"
0...600 m3/h, 0...2650 gal/min
-40...150C / -40...300F
PN 40
Cl 150
+/- 0.5% o.r. +/- 0.01% o.f.s. for v > 0.5 m/s (optional
0.3% o.r.)
+/- 0.035% o.f.s. for v<0.5 m/s)
Reynolds number > 10.000
Two line backlit
Touch control
4...20mA
Impulse
Status
HART
Profibus PA
ATEX
FM
CSA
TIIS(In Preparation)
IP67
NEMA 4X
Loop powered
Multibeam
Non-invasive sensors
All stainless steel design
Compact and remote version
Safe and easy system integration
Short straight inlet requirements (5 x DN)
Non invasive
No internal process seals all welded design
Energy saving due to low power consuption
No pressure drop

Prosonic Flow Clamp On 92TA1


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Portable Ultrasonic Flow Measuring System


Temporary volume flow measurement of liquids with "Clamp On" sensors
Your benefits
Portable transmitter, battery operated, for temporary measurements
Built-in data logger with a capacity of 40000 measuring values
Site Setup operating menus for straightforward commissioning of up to 20 measurement
sites
"Clamp On" sensors, non-contact measurement technique
The sensors are affixed to the piping from the outside
Very wide range of nominal diameters
Sensors U DN 15...100
Sensors W DN 50...4000
Wide temperature range of -20...+80 C
Measuring transmitter in protected handheld housing in: IP 50
Sensors U in: IP 52
Sensors W in:
- IP 67 Sensorbody
- IP 52 BNC adapter
Interfaces
- Data readout software for use with a personal computer
- Current in- and outputs (4...20 mA)
Field of application

Ideally suited for temporary, bidirectional measurement of pure or slightly soiled liquids with
a gas content of < 1% or a solids content of < 5%.
Application examples:
Water, wastewater etc.
Ultrapure water with low conductivity
Process facilities
The "Clamp On" sensors are equally suitable for homogeneous piping as for piping made of
composite materials:
steel, plastic, GRP and glass pipes
Lined pipes

Prosonic Flow Clamp On 92TA1


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Portable transmitter, battery operated, for temporary measurements


Built-in data logger with a capacity of 40000 measuring values
Site Setup operating menus for straightforward commissioning of up to 20 measurement
sites
"Clamp On" sensors, non-contact measurement technique
The sensors are affixed to the piping from the outside
Very wide range of nominal diameters
Sensors U DN 15...100
Sensors W DN 50...4000
Wide temperature range of -20...+80 C
Measuring transmitter in protected handheld housing in: IP 50
Sensors U in: IP 52
Sensors W in:
- IP 67 Sensorbody
- IP 52 BNC adapter
Interfaces
- Data readout software for use with a personal computer
- Current in- and outputs (4...20 mA)
Water, wastewater etc.
Ultrapure water with low conductivity
Process facilities
steel, plastic, GRP and glass pipes
Lined pipes
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter

Ultrasonic
Portable volume flow measurement of liquidsfrom
outside with "Clamp On" sensors.
U-Sensor:
- DN 15...100
- 1/2"...4"
W-Sensor:
- DN 50...4000
- 2"...160"

Measuring range

Process temperature

Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Protection electronic
Features

Advantages

P-Sensor:
- DN 50...300
- 2"...12"
U-Sensor: 0...424 m3/h
W-Sensor: 0...678'550 m3/h
P-Sensor: 0...678'550 m3/h
DN15...4000
-20...+80C
(-4...+176F)
DN50...300
-0...+170C
(32...+338F)
No limit
+/-2.0 %
Large graphic display.
Push button keyboard.
4...20mA
4...20mA
PC-Serial (RS 232)
IP 50
Memory for storing 20 measuring sites
Data logger for 40 000 values
PC software for data read-out
Portable, battery-powered transmitter for temporary
measurements
"Clamp-On" sensors: Non-contact measurement
Sensors are clamped to pipe installations from the
outside
Transmitter in protected, portable housing in IP 50
protection type
"U" sensors: IP 54
"W" sensors:
- Sensor housing with IP 67 protection type
- BNC adapter in IP 54
"P"-Sensors: IP68

Prosonic Flow Clamp On 92TA1


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Portable transmitter, battery operated, for temporary measurements


Built-in data logger with a capacity of 40000 measuring values
Site Setup operating menus for straightforward commissioning of up to 20 measurement
sites
"Clamp On" sensors, non-contact measurement technique
The sensors are affixed to the piping from the outside

Very wide range of nominal diameters


Sensors U DN 15...100
Sensors W DN 50...4000
Wide temperature range of -20...+80 C
Measuring transmitter in protected handheld housing in: IP 50
Sensors U in: IP 52
Sensors W in:
- IP 67 Sensorbody
- IP 52 BNC adapter
Interfaces
- Data readout software for use with a personal computer
- Current in- and outputs (4...20 mA)
Water, wastewater etc.
Ultrapure water with low conductivity
Process facilities
steel, plastic, GRP and glass pipes
Lined pipes
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter

Measuring range

Process temperature

Pressure range
Measured error
Display/Operation
Inputs
Outputs
Communication
Protection electronic
Features

Advantages

Ultrasonic
Portable volume flow measurement of liquids from
outside with "Clamp On" sensors.
U-Sensor:
- DN 15...100
- 1/2"...4"
W-Sensor:
- DN 50...4000
- 2"...160"
P-Sensor:
- DN 50...300
- 2"...12"
U-Sensor: 0...424 m3/h
W-Sensor: 0...678'550 m3/h
P-Sensor: 0...678'550 m3/h
DN15...4000
-20...+80C
(-4...+176F)
DN50...300
-0...+170C
(32...+338F)
No limit
+/-2.0 %
Large graphic display.
Push button keyboard.
4...20mA
4...20mA
PC-Serial (RS 232)
IP 50
Memory for storing 20 measuring sites
Data logger for 40 000 measuring values
PC-Software for data read-out
Portable, battery-powered transmitter for temporary

measurements
"Clamp-On" sensors: Non-contact measurement
Sensors are clamped to pipe installations from the
outside
Transmitter in protected, portable housing in IP 50
protection type
"U" sensors: IP 54
"W" sensors:
- Sensor housing with IP 67 protection type
- BNC adapter in IP 54
"P"-Sensors: IP68

Prosonic Flow Inline 93C


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a inline
unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Diagnostic ability and data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
No pressure loss
Dual-path version for short inlet runs
Guaranteed and attestable accuracy
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids
For water/wastewater applications
Approvals for hazardous area:
ATEX, FM, CSA
Approvals in the food industry/hygiene sector:
Drinking water approval
Connection to process control system:
HART, PROFIBUS PA, FOUNDATION Fieldbus

Prosonic Flow Inline 93C


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
No pressure loss
Dual-path version for short inlet runs
Guaranteed and attestable accuracy
Applicable for all homogeneous fluids
For water/wastewater applications
ATEX, FM, CSA
Drinking water approval
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Ultrasonic
Flow volume measurement for standard applications
with drinking water and waste water.

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Advantages

DN 300...2'000
12"...AWWA 78"
0...47'000 m3/h 0...176 Mgal/min
-20...+60C / -4...140F
PN 16
Cl 150
+/-0.5 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4x
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Transmitter 93 in protected wall-mount housing in IP
67 protection type
"Quick Setup" menus fr easy operation
High accuracy
Traceable calibration

Prosonic Flow Inline 93C


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
No pressure loss
Dual-path version for short inlet runs
Guaranteed and attestable accuracy
Applicable for all homogeneous fluids
For water/wastewater applications

ATEX, FM, CSA


Drinking water approval
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement for standard applications
with drinking water and waste water.
DN 300...2'000
12"...AWWA 78"
0...47'000 m3/h 0...176 Mgal/min
-20...+60C / -4...+140F
PN 16
Cl 150
+/-0.5 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4x
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Transmitter 93 in protected wall-mount housing in IP
67 protection type
"Quick Setup" menus fr easy operation
High accuracy
Traceable calibration

Prosonic Flow Clamp On 93P


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Volume flow measurement of liquids in chemical or process applications
Your benefits
Prosonic Flow clamp-on is the flexible and cost-effective flow measuring system.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Diagnostic ability and data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
Approvals for hazardous area:
ATEX, FM, CSA, TIIS
Connection to process control system:
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus

Prosonic Flow Clamp On 93P


General
information

Technical
information

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product Picture

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA, TIIS
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals

Protection electronic
Features

Ultrasonic
Flow volume measurement from outside for fluids in
chemical or process applications.
DN 50...4'000
2"...160"
0...678'550m3/h
-40...+170C / -40...338F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
ATEX
FM
CSA
TIIS
IP 67
NEMA 4x
T-DAT, F-CHIP

Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Non-invasive measurement from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection type
Standard transmitter in IP 68
Software packages may be updated
"Quick Setup" menus for straightforward
commissioning in the field
Remote parameter setting possible via the FieldTool
software package
Flow sensors are approved for use in Zone 1 as a
standard

Advantages

Prosonic Flow Clamp On 93P


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Robust, industrial design for a high degree of reliability in the process
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For chemical or process applications
Wide fluid temperature range -40...+170 C
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA, TIIS
HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Ultrasonic
Flow volume measurement from outside for fluids in

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals

Protection electronic
Features

Advantages

chemical or process applications.


DN 50...4000
2"...160"
0...678'550 m3/h
-40...+170C / -40...338F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
ATEX
FM
CSA
TIIS
IP 67
NEMA 4x
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Non-invasive measurement from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection type
Standard transmitter in IP 68
Software packages may be updated
"Quick Setup" menus for straightforward
commissioning in the field
Remote parameter setting possible via the FieldTool
software package
Flow sensors are approved for use in Zone 1 as a
standard

Prosonic Flow Clamp On 93U


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a clamp-on
unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Diagnostic ability and data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
Approvals for hazardous area:
ATEX, FM, CSA
Connection to process control system:
HART, PROFIBUS PA, FOUNDATION Fieldbus

Prosonic Flow Clamp On 93U


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with small pipe sizes.
DN 15...100
1/2"...4"
0...424 m3/h
-20...+80C / -4...176F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Puls/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4X
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Non-invasive measurment from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection type
Transmitter in IP 54
"Quick Setup" menus for straightforward
commissioning
Easy and cost-effective mounting

Prosonic Flow Clamp On 93U

General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Ultrasonic
Flow volume measurement from outside for standard
applications with small pipe sizes.
DN 15...100
1/2"...4"
0...424 m3/h
-20...+80C / -4...176F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Puls/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4X
T-DAT, F-CHIP
Validation

Advantages

Quick Set-Up
Sonic speed output
3 Totalizers
Advanced diagnosis
Non-invasive measurment from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection type
Transmitter in IP 54
"Quick Setup" menus for straightforward
commissioning
Easy and cost-effective mounting

Prosonic Flow Clamp On 93W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Product description
Field of application
Order information
Product description

Ultrasonic Flow Measuring System


Flowrate measurement for standard applications with drinking water, wastewater and process
water
Your benefits
Prosonic Flow, the flexible and cost-effective flow measuring system, available as a clamp-on
or insertion unit, offers you a tailor-made solution.
The Proline transmitter concept comprises:
Modular device and operating concept resulting in a higher degree of efficiency
Diagnostic ability and data back-up for increased process quality
The tried-and-tested Prosonic Flow sensors offer:
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Optionally available as insertion dual-path version for short inlet runs
Field of application

The sensors are perfectly suited for bidirectional measurement of pure or slightly
contaminated liquids, regardless of the pressure, temperature, conductivity and viscosity.
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
Approvals for hazardous area:
ATEX, FM, CSA
Connection to process control system:
HART, PROFIBUS PA, FOUNDATION Fieldbus

Prosonic Flow Clamp On 93W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Optionally available as insertion dual-path version for short inlet runs
Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water, waste water and

Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Advantages

process water.
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4x
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Pulsating flow
Advanced diagnostics
Non-invasive measurement from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection form
Sensor in IP 67 / IP 68 protection form
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting Short inlet runs
with dual path measurement

Prosonic Flow Clamp On 93W


General
Technical
information
information
Product Picture

Documents/
Software

Service

Accessories/
Spare parts

Successor

Modular device and operating concept resulting in a higher degree of efficiency


Diagnostic ability and data back-up for increased process quality
Easy and safe installation and commissioning guarantee precise measurement
Insensitivity to vibrations
No pressure loss
Optionally available as insertion dual-path version for short inlet runs

Applicable for all homogeneous fluids in acoustically transmissive pipes, even with lining
For water/wastewater applications
Ideal for retrofitting
Installation without process interruption
ATEX, FM, CSA
HART, PROFIBUS PA, FOUNDATION Fieldbus
Print this page

Recommend this page

Bookmark this page

Technical data
Conductive Liquids
Non Conductive Liquids

Measuring Principle
Main features
Diameter
Measuring range
Process temperature
Pressure range
Measured error
Display/Operation
Inputs
Outputs

Communication

Ex-Approvals
Protection electronic
Features

Advantages

Ultrasonic
Flow volume measurement from outside for standard
applications with drinking water and waste water.
DN 50...4000
2"...160"
0...678'550 m3/h
-20...+80C / -4...+176F
No limit
+/-2.0 %
Four line backlit
Touch control
Status
4...20mA
Pulse/Frequency (10KHz, active/passive)
Relays/Status
HART
Profibus PA
Profibus DP
Foundation Fieldbus
FM
CSA
IP 67
NEMA 4x
T-DAT, F-CHIP
Validation
Quick Set-Up
Sonic speed output
3 Totalizers
Pulsating flow
Advanced diagnostics
Non-invasive measurement from outside "Clamp On"
Transmitter 93 in protected wall-mount housing in IP
67 protection Flow sensors in IP 67 / IP 68 protection
"Quick Setup" menus for straightforward operation
Easy and cost-effective mounting Short inlet runs
with dual path measurement

Vous aimerez peut-être aussi