Vous êtes sur la page 1sur 49

MXcatCOVandback.

QXD 11/10/02 11:51 pm Page 1


23SeptMXCat. qxd 11/10/02 11:42 pm Page 1

Introduction

Tyco MX Technology brings together the latest fire


detection technology from around the world into a
comprehensive international range of fire detection
systems. Tyco MX Technology can be used to
provide cost effective solutions on small fire detection
systems whilst also providing the features and
functions required on very large commercial and
industrial sites.
Tyco MX Technology is being made available on a
wide range of internationally approved panels and
systems available from Tyco companies world-wide
including:

. MINERVA MX PANELS
. MINERVA MARINE T2000 PANELS
. ZETTLER EXPERT PANELS
. MINERVA SOLO PANELS

Features:

. MX VIRTUAL multi-sensor detectors


. MX DIGITAL robust & reliable high speed loop protocol
. Rapid response to fire conditions and very low false alarms through:
. MX FASTLOGIC detection algorithms
. MX HPO detection algorithms
. MX CCO fire detection

Page 1
23SeptMXCat. qxd 11/10/02 11:42 pm Page 2

Table of Contents
3 MX Panels
10 MX Panel Components

15 MX Panel User Interface Modules

19 MX Graph/ MX Net

21 Minerva Solo Detection Panels

22 Batteries

23 MX Virtual Multi-Sensor Detectors

26 Detector Mode Selection &


Design Charts

28 Standard Universal Bases

29 Functional Detector Bases

30 Detector Ancillaries

34 Detector Housings

35 MX Ancillary

38 MX Addressable
Input/Output Modules

42 MX Ancillary Housing

44 Programming & Service


Tools

45 Sales Tools

46 Approvals

47 Standard Auto CAD Symbols

tyco
48 Product Code Index

Page 2
23SeptMXCat. qxd 11/10/02 11:42 pm Page 3

MX Panels
MX Detection Panels

Tyco MX detection
panels use all the features of Tyco MX Technology Tyco MX detection panels include:
to provide the latest fire detection technology . MINERVA MX for EN54 LPCB approved . Viewing and printing status
meeting the latest worldwide standards in cost- systems
effective, expandable packages. . ZETTLER EXPERT for EN54 LPCB & VdS . Viewing and printing isolated points
Tyco MX detection panels support Tyco approved systems . Manual and automatic walk test and reporting
functions
MX Technology: . MINERVA EXPERT T2000 for Marine approved
systems
. MX VIRTUAL Multi-sensor detectors . Viewing and printing maintenance reports
Other variants available soon will carry UL, ULC,
. MX DIGITAL high speed reliable digital . Extensive diagnostic functions including
FM, SSL and other European listings and
protocol simulation and force outputs
approvals.
. MX FASTLOGIC fuzzy logic smoke detection
Tyco MX detection panels include a . Text and configuration changes
algorithms
powerful user interface:
. MX CCO universal carbon monoxide fire . Automatic battery test
detection algorithms . 640 Character display
. Detector service functions
Tyco MX detection panels provide . Displays first alarm and most recent alarm
Tyco MX detection panels include very
modular cost effective solutions: . Permanently displays systems status including
. Networked panels from 1 to 396 detection powerful event/action programming
number of alarms, number of faults, number of
loops isolated points including:
. Powerful central loop processing functions . Scroll function allows details of all events and . Seamless network wide event/action
status to be easily viewed . 240 x 240 Output map and output sequencing
. Powerful and modular user interface algorithms
. Displays temperature, CO level and smoke
. MX REMOTE diagnostics and service level at point in alarm . Over 1500 event/action groups for the most
functions complex applications
. Displays 95 character custom messages for
emergency procedures . Templates for fast programming of standard
. MX GRAPH graphical user interfaces
Tyco MX panels include advanced applications including:
. Designer and modular housing options - EN54/BS5839
manager and engineer functions
- EN54/VdS
Tyco MX detection panels provide long term fire
including: - EN54 Marine
detection solutions including upgrade paths from
earlier panel models and a long term develop- . Menu driven
. User defined templates
ment strategy providing future upgrade paths.
. Multi-level password protected
. Time, date and special day programming
. Viewing 1000 event log . Wide range of co-incidence, double knock
and delay functions
. Detailed fault reporting

. Isolate by point, zone or sector

Page 3
23SeptMXCat. qxd 11/10/02 11:42 pm Page 4

MINERVA MX1000 & MX4000


incorporates the ODM800 operator display Product Codes
module with a 16 x 40-character backlit LCD Standard Panels
display, simple alphanumeric keypad, 5 softkeys 557.200.001
and a fast access key. The OCM800 operator MX1000 Single Loop Panel Shallow Back Box
control module provides all mandatory operator 557.200.020
control keys and LED functions including MX1000 Single Loop Panel- Shallow Back Box -
Day/Night switching. Two control keys and 2 DANISH
indication LEDs are provided for site-specific 557.200.021
functions. MX1000 Single Loop Panel- Shallow Back Box -
Control keys and LEDs are labelled in English DANISH/ENGLISH
according to the default LPCB functionality. The 557.200.002
slide in decals can be reversed and alternative MX1000 Single loop panel - Flush Back Box
text added. 557.200.003
MX4000 Two to Four Loop Panel Shallow Back
Box
The MINERVA MX panels are intelligent LPCB 557.200.022
EN54 approved* panels, which can be networked MX4000 Two to Four Loop Panel - Shallow Back
to provide up to 396 detection loops and installed Box - DANISH
to BS5839:Pt.1. 557.200.023
. The MX1000 supports one MX DIGITAL MX4000 Two to Four Loop Panel - Shallow Back
detection loop with up to 250 addressable Box - DANISH/ENGLISH
devices. 557.200.004
. The MX4000 supports two MX DIGITAL MX4000 Two to Four Loop Panel Deep Back
detection loops and can be expanded to four Box
loops supporting up to 1000 addressable 557.200.009
devices. MX4000 Two to Four Loop Panel - Flush Back
Box
Both panels consist of a strong steel enclosure Options
incorporating a removable chassis plate. The 557.202.006
chassis plate holds: IOB-800 (8in/8out) expansion board (Max. 24 I/O
. PSB800 5A 24Vd.c. battery backed power on main panel)
supply and loop booster to EN54:pt.4 557.202.007
. FIM800 field interface PCB incorporating one XLM-MX two loop MX DIGITAL expansion card
or two MX DIGITAL loops 557.202.026
. CPU800 32 bit processor and memory card TLI-800 ThornNet & MX-NET network card
. Optional network card, additional loop card (s) 557.202.036
and remote diagnostic modem Remote Diagnostic Modem
. Optional IOB800 input/output expansion card 557.202.116
mounted on the PSB800 Modem Lead
The panel has a strong cast aluminium front door, 557.202.118
which incorporates a modular user interface that MX CONSYS download lead
fully complies with EN54:pt.2. The user interface

Battery & Expansion Boxes

The batteries and any additional zone LEDs or the zone LED modules pre-fitted.
operator controls and firemans interface are Product Code Where no additional controls are required the low
mounted in a separate housing which can be 557.200.007 cost MX-BATT battery box can be used for
mounted below the main panel or behind the MX-BBX-40LED 17Ah battery box with 40 zone housing up to 38Ah batteries and IOB800 boards.
panel. The matching battery and expansion box is LEDs Product Code
available with shallow (17Ah) or deep backbox 557.200.008 557.200.016
(38Ah) according to the batteries used. The MX-DPBBX-40LED 38Ah battery box with 40 Zone MX-BATT Deep battery box
chassis plate in the battery box also has space LEDS.
for up to 2 x IOB800 input/output expansion
modules (maximum 24 I/O) or 1 x MX FILNET or
1 x PSM/PSB800.

Product Codes
557.200.005
MX-BBX 17Ah shallow expansion and battery box
557.200.019
MX-BBX-F 17 Ah shallow flush expansion and
battery box
557.200.006
MX-DPBX 38Ah deep expansion and battery box
Certain popular configurations are available with

Page 4
23SeptMXCat. qxd 11/10/02 11:42 pm Page 5

MINERVA MX Modular Panels


or two MX DIGITAL loops Product Codes
. CPU800 32 bit processor and memory card Standard Panels
. Optional network card, additional loop card (s) 557.200.100
and remote diagnostic modem MX4000M Two to Four Loop Panel 3 Tier Deep
The panel has a lockable architectural front door housing
with lockable window, which incorporates a 557.200.101
modular user interface that fully complies with MX4000M Two to Four Loop Panel 5 Tier Deep
EN54:pt.2. The user interface incorporates the housing
ODM800 operator display module with a 16 x 40- Options
character backlit LCD display, simple 557.202.006
alphanumeric keypad, 5 softkeys and a fast IOB-800 (8in/8out) expansion board (Max. 24 I/O
access key. The OCM800 operator control on main panel)
module provides all mandatory operator control 557.202.007
keys and LED functions including Day/Night XLM-MX two loop MX DIGITAL expansion card
switching. Two control keys and 2 indication LEDs 557.202.026
The MINERVA MX Modular panels are intelligent are provided for site-specific functions. TLI-800 ThornNet & MX-NET network card
LPCB EN54 approved panels, which can be 557.202.036
networked to provide up to 396 detection loops Control keys and LEDs are labelled in English Remote Diagnostic Modem
and installed to BS5839:Pt.1. according to the default LPCB functionality. The 557.202.116
The MX4000M supports two Tyco MX DIGITAL slide in decals can be reversed and alternative Modem Lead
detection loops and can be expanded to four loops text added. 557.202.118
supporting up to 1000 addressable devices. MX CONSYS Download lead
The modular panels are manufactured so they The panel incorporates sufficient space to
can be retrofitted into the TFX series of fire accommodate 2 x 17Ah or 2 x 38Ah batteries and
controllers, for upgrades. The construction of sufficient space in the front door to take 2 or 6
the modular units is not the standard 19 inch rack additional user interface modules including 80
mounting system. The panel consists of a strong way red LED module (ANN880) , 40 way
rack style steel enclosure which can be surface or red/yellow LED module or 20 way
semi-flush mounted. status/command firemans interface module.
The main removable chassis plate holds:
. PSB800 5A 24Vd.c. battery backed power
supply and loop booster to EN54pt4
. FIM800 field interface PCB incorporating one

MINERVA MX Repeaters
The MINERVA MX repeater with Power Supply is Product Codes
connected to the Panel via the remote bus Standard Repeaters
(RS485, 1200 m distance). A maximum of 2 557.200.012
repeaters (including one MX REMOTE repeater) MXR Repeater with shallow backbox
can be linked to each MINERVA MX panel and 557.200.017
can provide full repeater functions for all panels MXR-F Repeater with flush backbox
on the system. 557.200.013
MXR-PSU Repeater and addressable PSU
The operator control module (OCM800) can 557.200.018
support up to 80 inputs and outputs in the form of MXR-PSU-F Repeater and addressable PSU with
LED annunciators, IOB800 input/output modules, flush backbox
XIOM universal I/O modules or XIOM 800 LED Options
mimic module. 557.202.006
IOB-800 (8in/8out) expansion board
557.180.005
The MINERVA MX full function repeater is an Mimic driver module
EN54 LPCB approved repeater with optional 557.180.016
addressable EN54:Pt.4 power supply. The XIOM universal I/O module
repeater consists of a steel backbox and cast 557.202.028
aluminium front door which incorporates the RSM800 PSU Module
ODM800 operator display module with a 16 x 40- 557.202.042
character backlit LCD display, simple 24VDC Repeater Cable Assembly
alphanumeric keypad, 5 softkeys and a fast
access key. The OCM800 operator control
module provides all mandatory operator control
keys and LED functions including Day/Night
switching. Two control keys and 2 indication LEDs
are provided for site-specific functions.

Control keys and LEDs are labelled in English


according to the default LPCB functionality. The
slide in decals can be reversed and alternative
text added.

The back box has a removable chassis plate with


the PSM800 power supply, APM800 addressable
PSU monitor and space for 2 x 7 Ah batteries to
provide 72 h backup.

Page 5
23SeptMXCat. qxd 11/10/02 11:42 pm Page 6

MINERVA Expert T2000 Marine Detection Panel


The panel has a strong cast aluminium front door, Product Codes
which incorporates a modular user interface that 557.200.600
fully complies with EN54 pt2. The user interface T2000 Two To Four Loop Marine Panel
incorporates the ODM800 operator display 557.200.602
module with a 16 x 40-character backlit LCD T2000B Battery Box
display, simple alphanumeric keypad, 5 softkeys
and a fast access key. The OCM800 operator
control module provides all mandatory operator
control keys and LED functions including
Day/Night switching. Two control keys and 2
indication LEDs are provided for vessel specific
functions.
Control keys and LEDs are labelled in English
according to the default Marine functionality. The
slide in decals can be reversed and alternative
The T2000 is a fully Marine approved EN54
text added.
compliant 1 to 4 loop networkable detection
The batteries and any additional zone LEDs or
panel. The T2000 supports two Tyco MX DIGITAL
operator controls are mounted in a separate
detection loops and can be expanded to four
housing which can be mounted below the main
loops supporting up to 1000 addressable
panel or behind the panel. The battery box has a
devices.
heavy duty backbox and battery clamp. The
The T2000 consists of a strong steel Marine
chassis plate in the battery box also has space for
approved enclosure incorporating:
up to 2 x IOB800 input/output expansion modules
. PSB800M 5A 24V DC battery backed power
(maximum 24 I/O) or 1 x PSM/PSB800.
supply and loop booster to EN54pt4
. FIM800 field interface PCB incorporating one
or two MX DIGITAL loops
. CPU800 32 bit processor and memory card
. Optional network card and additional loop
card(s)

MINERVA Expert T2000 Marine Repeater


according to the default Marine functionality. The Product Codes
slide in decals can be reversed and alternative 557.200.601
text added. T2000R Marine Repeater with Power Supply Unit
The back box has a removable chassis plate with 557.200.604
the PSM800M power supply, APM800 T2000R Marine Repeater without Power Supply
addressable PSU monitor and space for 2 x 7 Ah Unit
batteries to provide 72 h backup.
The T2000 repeater with Power Supply is
connected to the Panel via the remote bus
(RS485, 1200 m distance). A maximum of x 2
repeaters (including one MX REMOTE repeater)
can be linked to each T2000 panel and can
provide full repeater functions for all panels on
the system.
The T2000 full function repeater is an EN54 The operator control module (OCM800) can
Marine approved repeater with optional support up to 80 inputs and outputs in the form of
addressable EN54:Pt.4 power supply. The LED annunciators, IOB800 input/output modules,
repeater consists of a steel backbox and cast XIOM universal I/O modules or XIOM 800 LED
aluminium front door which incorporates the mimic module.
ODM800 operator display module with a 16 x 40-
character backlit LCD display, simple
alphanumeric keypad, 5 softkeys and a fast
access key. The OCM800 operator control
module provides all mandatory operator control
keys and LED functions including Day/Night
switching. Two control keys and 2 indication LEDs
are provided for vessel-specific functions.
Control keys and LEDs are labelled in English

Page 6
23SeptMXCat. qxd 11/10/02 11:42 pm Page 7

ZETTLER Expert 1000 & 4000


The ZETTLER EXPERT panels are intelligent Product Codes
LPCB & VdS certified EN54 panels, which can Standard Panels
be networked to provide up to 256 detection 542.080
loops. ZX1 1 Loop Panel c/w Deep 38Ah Battery Box
Features 542.081
. The ZX1 supports one Tyco MX DIGITAL ZX4 2 - 4 Loop Panel c/w Deep 38Ah Battery
detection loop with up to 250 addressable Box
devices or 128 for VdS certified installations. Options
. The ZX4 supports two Tyco MX DIGITAL 542.006
detection loops and can be expanded to four IOB-800 (8in/8out) expansion board (Max. 24 I/O
loops supporting up to 1000 addressable on main panel)
devices or 512 devices for VdS certified 542.007
installations. XLM-MX two loop MX DIGITAL expansion card
Both panels consist of a strong deep steel 542.010
enclosure incorporating a removable chassis TUD-800 German Transmission Unit
plate. The chassis plate holds: 542.025
. PSB800 5A 24V DC battery backed power MX-FIL FILNET network card
supply and loop booster to EN54:pt.4 542.026
. FIM800 field interface PCB incorporating one TLI800 MX-NET Network card
or two MX DIGITAL loops 542.036
. CPU800 32 bit processor and memory card Remote Diagnostic Modem
. Optional network card, additional loop card (s) 542.008
and remote diagnostic modem Modem lead
The panel has a strong cast aluminium front door, 542.011
which incorporates a modular user interface that MX CONSYSDownload lead
fully complies with EN54:pt.2. The user interface
incorporates the ODM800 operator display
module with a 16 x 40-character backlit LCD
display, simple alphanumeric keypad, 5 softkeys
and a fast access key. The OCM800 operator
control module provides all mandatory operator
control keys and LED functions including
Day/Night switching. Four control keys and 4
indication LEDs are provided for site-specific
functions.
Control keys and LEDs are labelled in German
according to the default VdS functionality. The
slide in decals can be reversed and alternative
text added.
The batteries and any additional zone LEDs or
operator controls are mounted in a separate
housing which can be mounted below the main
panel or behind the panel. This expansion battery
box is supplied with the panel as a deep box to
take 38Ah batteries. The chassis plate in the
battery box also has space for up to 2 x IOB800
input/output expansion modules (maximum 24
I/O) or a TUD800 German Fire Brigade
transmission unit.
The battery box can have one or two 40 way zone
indicators (ANN840) mounted in the front door.

ZETTLER Expert Repeaters


The ZETTLER EXPERT full function repeater is an The ZETTLER EXPERT Repeater with Power
EN54 LPCB & VdS certified repeater with optional Supply is connected to the Panel via the remote
addressable EN54:Pt.4 power supply. The bus (RS485, 1200 m distance). A maximum of 2
repeater consists of a steel backbox and cast repeaters (including one MX REMOTE repeater)
aluminium front door which incorporates the can be linked to each ZETTLER EXPERT panel
ODM800 operator display module with a 16 x 40- and can provide full repeater functions for all
character backlit LCD display, simple panels on the system.
alphanumeric keypad, 5 softkeys and a fast The operator control module (OCM800) can
access key. The OCM800 operator control support up to 80 inputs and outputs in the form of
module provides all mandatory operator control LED annunciators and IOB800 in/output modules.
keys and LED functions including Day/Night Product Codes
switching. Four control keys and 4 indication Standard Repeaters
LEDs are provided for site-specific functions. 542.084
Control keys and LEDs are labelled in German ZXF Repeater with shallow backbox
according to the default VdS functionality. The 542.085
slide in decals can be reversed and alternative ZXFEV Repeater and addressable PSU
text added. Options
The back box has a removable chassis plate with 542.006
the PSM800 power supply, APM800 addressable IOB-800 (8in/8out) expansion board
PSU monitor and space for 2 x 7 Ah batteries to
provide 72 h backup.

Page 7
23SeptMXCat. qxd 11/10/02 11:42 pm Page 8

ZETTLER Expert Modular Panels


. FIM800 field interface PCB incorporating one Product Codes
or two MX DIGITAL loops Standard Panels
. CPU800 32 bit processor and memory card 542.090
. Optional network card, additional loop card (s) ZX4-M3 2 to 4 Loop panel in 3 tier housing
and remote diagnostic modem 542.091
The panel has a lockable architectural front door ZX4-M5 2 to 4 Loop panel in 5 tier housing
with lockable window, which incorporates a Options
modular user interface that fully complies with 542.006
EN54:pt.2. The user interface incorporates the IOB-800 (8in/8out) expansion board (Max. 24 I/O
ODM800 operator display module with a 16 x 40- on main panel)
character backlit LCD display, simple 542.007
alphanumeric keypad, 5 softkeys and a fast XLM-MX two loop MX DIGITAL expansion card
access key. The OCM800 operator control 542.010
module provides all mandatory operator control TUD-800 German Transmission Unit
keys and LED functions including Day/Night 542.025
The ZETTLER Expert Modular panels are switching. Two control keys and 2 indication LEDs MX-FIL FILNET network card
intelligent LPCB EN54 approved panels, which are provided for site-specific functions. 542.026
can be networked to provide up to 396 detection Control keys and LEDs are labelled in English TLI800 MX-NET Network card
loops and installed to BS5839:Pt.1. according to the default LPCB functionality. The 542.036
The ZETTLERExpert supports two Tyco MX slide in decals can be reversed and alternative Remote Diagnostic Modem
DIGITAL detection loops and can be expanded to text added. 542.008
four loops supporting up to 1000 addressable The panel incorporates sufficient space to Modem lead
devices. accommodate 2 x 17Ah or 2 x 38Ah batteries and 542.011
The modular panels are manufactured so they sufficient space in the front door to take 2 or 6 MX CONSYSDownload lead
can be retrofitted into the TFX series of fire additional user interface modules including 80
controllers, for upgrades. The construction of the way red LED module (ANN880) , 40 way
modular units is not the standard 19 inch rack red/yellow LED module or 20 way
mounting system. status/command firemans interface module.
The panel consists of a strong rack style steel
enclosure which can be surface or semi-flush
mounted. The main removable chassis plate
holds:
. PSB800 5A 24Vd.c. battery backed power
supply and loop booster to EN54pt4

MX Detection Panels - Technical Specification & System Schematics


MX Detection Panels - Designer Housing Technical Specification

Shallow Housing Flush Shallow Housing Deep Housing Marine


Dimensions (mm) 320Hx440Wx120D 380Hx500Wx120D 320Hx440Wx215D 320Hx440Wx135D
Approx Weight 7Kg 7.2Kg 8Kg 14Kg
Temperature (Storage) -20oC to +70 oC -20oC to +70 o C -20oC to +70 oC -20oC to +70 oC
Temperature (Operating) -8oC to +55o C -8oC to +55 oC -8oC to +55 oC -8o C to +55 oC
Humidity up to 95% RH, Non-Condensing
Colour (Housing) Dawn Grey (BS 4800 10A - 03)
Colour (Modules) Pantone 431C
EMC/RFI EN 50130-4
Shock EN 54-2
Vibration EN 54-2

MX Detection Panels - Modular Housing Technical Specification

3 Tier 5 Tier
Dimensions (mm) 588H x 600W x 200D 854H x 600W x 200D
Approx Weight 22.5Kg 31.5Kg
Temperature (Storage) -20oC to +70 oC -20oC to +70 o C
Temperature (Operating) -8oC to +55o C -8oC to +55 oC
Humidity up to 95% RH, Non-Condensing
Colour (Housing) Dawn Grey (BS 4800 10A-03)
Colour (Modules) Pantone 431C
EMC/RFI EN 50130-4
Shock EN 54-2
Vibration EN 54-2
Lockable Window On MX4000M Versions Only

Page 8
23SeptMXCat. qxd 11/10/02 11:42 pm Page 9

DESIGNER HOUSING SCHEMATIC


24Vd.c. 24Vd.c. Field I/O Network PC/Modem
Non-Resettable Resettable
Printer

CPU
ODM
TLI
PSB

RBus FRONT
FIM
DOOR
Loop C
XLM Loop A
Loop D OCM
110-240Va.c.
Loop B

MAIN PANEL HOUSING XBus

TUD/ ANN880
IOB PSB/PSM ANN840
IOB
or COM820
MX
FILNET FRONT
DOOR

ANN880
17 or 38Ah 17 or 38Ah ANN840
MPM
or COM820

BATTERY & EXPANSION HOUSING Remote bus up to 15 addresses a combination of


up to 7 x OCM and 15 x MPM Maximum

MODULAR/RACK HOUSING SCHEMATIC


Field I/O Network PC/Modem
24Vd.c.
Non-Resettable 24Vd.c. Printer
Resettable

R Bus
CPU OCM ODM
TLI
PSB

FIM XBus

Loop C ANN880 ANN880


XLM ANN840 MPM ANN840
Loop A
or COM820 or COM820
Loop D
110-240Va.c.
Loop B

PSB/PSM
TUD/ IOB
IOB MX
FILNET

FRONT
DOOR

17 or 38Ah 17 or 38Ah

BACKB OX

Remote bus up to 15 addresses a combination of


up to 7 x OCM and 15 x MPM Maximum

Page 9
23SeptMXCat. qxd 11/10/02 11:42 pm Page 10

MX Panel Components
CPU800 Expert Central Processor
detection panels. The Board provides 4 serial channels to the
The CPU-800 contains a Data Memory (SRAM), a FIM800 - 2 for RS232 (PCs, modems, printer
Program Memory (Flash EPROM), a Configuration and/or data loggers), 1 for the remote bus
Memory (Flash EPROM) and a Boot ROM (RBUS) to the main user interface and repeaters
(EPROM). The use of flash EPROM allows and 1 for Network Port (FSI, ThornNet/MX Net or
program upgrades to be downloaded locally or MX-FILNET)
remotely without the need for changing chips. Technical Specification
The CPU-800 provides power for the following 32 bit Processor: Motorola 68331
functions: Data Memory SRAM: 1 MByte
. Full alarm and fault monitoring for up to 1000 Prog. Memory Flash EPROM: 2 MByte
addressable points including central loop Config. Memory Flash EPROM: 1 Mbyte
processing of MX Fastlogic expert algorithms Boot EPROM: 64 kByte
. Concurrent operation of the main user Number of serial Interfaces: 4
interface and 2 remote user interfaces Quiescent Current: 67mA
including one remote dial up or networked Alarm Current: 67mA
The CPU-800 provides the main processing user interface Product Codes
power behind the MX detection panels. It is a . Peer to peer interaction with up to 99 other MX 557.202.002 (Spare only)
multi-layer PCB and contains the CPU, the detection panels CPU800 standard MX central processor (UK)
memory and interface electronics. The CPU-800 . Cause and core effect using up to 1000 input, 542.002 (Spare only)
plugs into the Field Interface Module (FIM800) output groups, delay timers and logic CPU800 standard MX central processor
which forms the motherboard in most MX functions (EUROPE)

FIM800 Field Interface Module


drivers on the FIM. This reduces downtime and Technical Specification
maintenance costs. The FIM can also take a Dimensions: 25H x 105W x 196D mm
variety of loop cards to support other addressable Weight: 156g
loop protocols. Power Consumption:119mA (Quiescent -
The FIM incorporates the following local I/O excluding loops and
connections: operator interface)
. 2 x reverse polarity monitored sounder 169mA (Alarm)
outputs Relay Outputs: 30Vd.c. @ 2A
. 2 x volt free outputs (Default alarm and fault) Monitored inputs: 10k Ohm EOL, 3KHz in
. 1 monitored input (eg. Day/Night changeover) parallel
. 1 emergency alarm input RBUS: RS-485 , default 19.6kB, up
. 1 unmonitored input (eg. Class Change or to 1200m
Tamper) Serial Ports: RS232C, 19.6kB, up to 10m
. Full monitoring of PSB800 power supply Local I/O Expansion:Up to 2 modules, up to 24
. Ground fault monitoring I/O, max. 300mm
The FIM incorporates a local I/O bus which allows Product Codes
The Field Interface Module FIM is the main the local I/O connections to be increased by 24. A 557.202.000
interface for field wiring on MX detection panels variety of I/O expansion boards are available FIM801 field interface module with one MX loop
and contains plug-in field wiring terminals, inter including: driver (UK)
board connectors, EMC protectors and filters and . IOB800 (8 in/8 out) expansion board 557.202.001
general I/O electronics. . TUD800 German Transmission Unit FIM802 field interface module with two MX loop
The FIM801 provides 1 x MX DIGITAL loop and The FIM includes two connections to the RBUS drivers (UK)
the FIM802 provides 2 x MX DIGITAL loops. Each one for the local user interface and one for 976262
MX DIGITAL loop can support several kilometres connecting up to 15 remote addresses in the SIM Serial Isolation Module (UK)
of loop wiring using a mixed topology using form of up to 2 x operator control modules 542.000
multiple loops and spurs. Typically the MX (OCM800) or up to 15 multi-purpose modules FIM801 field interface module with one MX loop
DIGITAL loop supports up to 2km of MICC or (MPM800). driver (EUROPE)
equivalent soft skinned fire proof cable. The FIM provides 3 configurable external serial 542.001
The FIM provides up to 495mA of loop power to ports : FIM802 field interface module with two MX loop
each loop to drive loop powered sounders and . Port 1 Local printer drivers (EUROPE)
other loop power devices. An optional plug-in . Port 2 Configuration PC or remote 542.023
additional loop card (XLM800-MX) provides a total diagnostics and upload/download SIM Serial Isolation Module (EUROPE)
of 4 x MX DIGITAL loops. In the event any loop modem
driver circuitry on the FIM becomes damaged a . Port 3 FSI open protocol or Network
second loop card can be fitted to replace the loop card/gateway (TLI-800 or MX-FIL)

Page 10
23SeptMXCat. qxd 11/10/02 11:42 pm Page 11

FIM TO IOB800 CONNECTION DETAILS

MX Loop Expansion Module


The XLM800 Loop Expansion Module fits Technical Specification
piggyback style onto the FIM or an existing Dimensions: 17.5H x 104W x 196Dmm
XLM 800 and is used to: Battery Requirements:
. Expand the capability of the MX4000C.I.E. two Standby 104.3mA + loop current
loop system to four loops Alarm 105.3mA + loop current
. Replace the FIM loops in case of a failure on Loop Current 495mA maximum
either a two or four loop system. Product Codes
The XLM800 Loop Expansion Module controls UK EUROPE
the communications between the detectors (and 557.202.007 542.007
other ancillaries) connected on the 2-wire loop XLM-MX Two Loop MX Digital ExpansionCard
circuits and the controller. In addition, the
addressable interface contains line isolation
circuits which protect the loop driver circuit from
short-circuit conditions.

Page 11
23SeptMXCat. qxd 11/10/02 11:42 pm Page 12

MPM800 Multi Purpose Interface Module


Up to 15 x MPM modules can be connected to Technical Specification
each panel of which 8 can be in the form of Dimensions: 25.4H x 92W x 167.64D mm
OCM800 (including the main OCM800 user Weight:: 98g
interface). One OCM800 can also be in the form Power Supply: 24Vd.c. (from
of an emulated user interface on a remote panel PSB or PSM800)
or PC connected via the network or dial up Power Consumption:35mA (Quiescent)
modem. 68mA Alarm subject to I/O
The following I/O and LED annunciator modules modules fitted
can be slaved from an MPM800: Communications: RS-485, up to 19.6kB
. Up to 5 x IOB800 (8 in/8 out expansion board) Printer Connection: Serial or Parallel
The MPM800 is used to provide various . Up to 5 x XIOM800 (16 way universal I/O Product Codes
expansion capabilities via the remote bus board) UK EUROPE
(RBUS). The MPM800 is provided as a . One Mimic Panel (80 way LED mimic driver 557.202.012 542.012
standalone module but is also incorporated into PCB) MPM800 multi-purpose interface module
the circuitry of the OCM800 operator control . One 80 way ANN880 LED mimic** 557.202.117 542.009
module to drive the LCD display, LEDs, keyswitch . One 40 way ANN840 LED mimic using red & Serial printer cable for MPM800 or FIM800
and keys on the OCM800 and the operator yellow LEDs** 976262 542.023
display module. The OCM800 and MPM800 have . Two 20 way COM820 LED status/command SIMSerial isolation module
an XBUS which can be used to drive up to 80 modules**
I/O. The MPM800 also has a printer interface for The MPM800 is mounted by plugging directly
connecting to a serial or parallel printer. onto the back of those items marked **

MPM800 TO XIOM CONNECTION DETAILS

Page 12
23SeptMXCat. qxd 11/10/02 11:42 pm Page 13

MPM 800 TO IOB800 CONNECTION DETAILS

PSM800 and PSB800 Power Supplies


Output reset) are provided. Battery voltage and consists of a PSB800 power supply module that
charger current readings are also provided to the comes with a loop booster module, an APM 800
FIM or APM for automatic battery testing. addressable monitor module, a battery
Screw terminals provide 2 x 24V outputs (24 V connecting cable and an XLM800 to APM800
stabilised, 24V stabilised with reset control) and connecting cable and maybe fitted onto the
one 5V output. chassis plate in the battery housing.
The power supply is fitted in a steel cage with
mounting points to allow any of the following
boards to be mounted: Product Codes
. APM800 addressable power supply monitor UK EUROPE
. FB800 fuse board with 15 x 24Vd.c. fused 557.200.014 542.088
spurs MXAPSU17 Boxed Addressable PSU (17Ah)
. IOB800 input/output expansion board 557.200.015 542.089
Technical Specification MXAPSU38 Boxed Addressable PSU (38Ah)
Dimensions: 50H x 114W x 190D mm Options
The MX power supply module is a state-of-the-art
Weight: 0.9Kg 557.202.003 542.003
integrated switch mode system power supply and
Input Voltage: 120-240 Vrms, 50/60Hz PSM800 Power Supply Only
battery charger, which can provide up to 5A
(Auto ranging) 557.202.403 NA
external and auxiliary loop power during alarm
Input Current: 0.8-1.6A RMS Rated Load PSM800M Marine approved power supply
conditions. It has a universal input allowing
Max. charge current : Up to 3.8A (dependant on 557.202.005 542.005
operation from 100 to 255 Va.c., 50 or 60 Hz. The
standby current) PSB800 Panel Power Supply c/w Loop Booster
power supply is approved* worldwide to EN54,
Max. battery size(24hr charge): 38Ah 557.202.405 NA
UL864 and Marine standards.
Max. total supply current: 5A@24Vd.c. PSB800M Marine Panel Power Supply (spare)
The charging voltage is temperature
Maximum external current: 4A@24Vd.c. 557.202.027 572.018
compensated. The PSM recharges the batteries
Output Voltages: 24Vd.c. APM800 Addressable Power Supply Monitor
within 24 h for the following timings:
(22.8 -26.4V) 557.202.050 NA
. 90h stand by time and 15 min. alarm condition
Non-resettable: 24Vd.c. @ 4A PSM800 Temp. Sensor Accessory kit
. 72h stand by time and 30min. alarm condition
Resettable: 24Vd.c. @ 4A 557.202.040 542.200
The power supply provides full condition and fault
5Vd.c. @ 3A PSB800K Power Expansion kit
monitoring to the system via the FIM (used by the
Power Consumption:PSB - 90mA 557.202.004
PSB800) or addressable power supply monitor
(quiescent & alarm) LBM800 Spare Loop Voltage Booster PCB
APM800 (used by the PSM800). The PSB800
incorporates the LBM800 booster module to PSM - 65mA
provide the correct voltage levels to maximise the (quiescent & alarm)
performance of the MX DIGITAL protocol.
Faults signals (Loss of AC, Battery charger fault, A PSB 800K Power Expansion Kit is required to
Battery fault) and control inputs (Battery test, power the XLM 800 pcb on 4 loop systems which
require the extended loop power capability. It

Page 13
23SeptMXCat. qxd 11/10/02 11:42 pm Page 14

FB800 Fuse Board


The FB800 fuse board provides terminations for Technical Specification
15 fused 24Vd.c. output spurs from a single 24V Dimensions: 93H x165W x 80D mm
d.c. input. The FB800 is designed to be normally Weight: 149g
mounted on the PSB800 or PSM800 power Input: 24Vd.c. (+10%/-5%)
supply. Output: 15 x 24V d.c / 500mA
The fuses are rated at 500mA. Terminations: 2.5mm
Product Codes
UK EUROPE
557.202.100 542.064
FB800 fuse board (15 way)

IOB800 Input/Output Expansion Board


The IOB800 is an LPCB & Vds approved* board The IOB800 can be mounted on the PSB800 panel
that provides 8 opto-isolated digital inputs and 8 x power supply, up to two in the top of a battery box
24V d.c. relay outputs for providing I/O expansion or repeater or in the back of a modular housing.
capabilities to MX detection panels for interfacing The IOB800 has two expansion bus connectors
to other subsystems and signalling devices. The which allow them to be daisy chained together.
IOB800 also incorporates a connector, which pro- Technical Specification
vides decoded signals for the 8 inputs and 8 out- Dimensions: 15H X 164W X 80D mm
puts for specialist interfacing. Weight: 153g
The IOB800 can be used to provide expansion I/O Power Consumption:29mA (Quiescent)
to the following MX panel components: 65mA (Maximum)
. FIM801/802 field interface modules (maximum Terminations: 1.5mm
16In/8Out) Product Codes
. OCM800 operator control modules (maximum UK EUROPE
80 I/O) 557.202.006 542.006
. MPM800 multi-purpose interface (maximum 80 IOB800 Expansion Board and cables
I/O)

TUD800 German Transmission Unit


The TUD800 is a VdS approved* input/output Product Codes
module specifically designed for interfacing the EUROPE
ZETTLER EXPERT panels to the German Fire 542.010
Brigade equipment. TUD800 German Transmission Unit
The TUD800 takes the place of an IOB800 when
used and is typically mounted in the deep
battery/expansion box.
Technical Specification
Dimensions: 15H x 164W x 80D mm
Weight: 153g
Power Consumption:29mA (Quiescent)
65mA (Alarm)

MX-FIL Filnet Gateway


Technical Specification Digital Outputs (short circuit proof):
Dimensions: 135H x 280W x 35D mm - Number of open collector outputs: 8
Weight (Approx): 330g - Current limitation: 50 mA
Serial interfaces (electr. isolated): Digital Inputs (overvolt. prot):
- No. Interfaces: 1 - Number of electr. isolated inputs: 8
- Parameters (coding plugs): - Series resistance to the opto-coupler
RS 232 / 422 / 485 LED 4.7 kohm
- Baud Rates: Programmable - Input voltage range 5 - 28 V
LON-interface (incl. NIF):
- No. Interfaces: 2
- Parameter FTT10 transceiver Product Codes
- Baud Rate: 78 kbit/s UK EUROPE
Voltage Supply: 557.202.025 542.025
The Filnet Gateway is an EN54 Vds approved - From control panel or external PS: MX-FILFilnet Gateway
network gateway which allows up to 64 MX 0V / +24Vd.c.
Panels to be networked onto a secure LONbased - Monitoring with XPSUMB:
FILNET Network. 0V / +5V / +24Vd.c.
The MX-FIL Gateway can be mounted in the Power Consumption:
designer battery box on the chassis plate or the - External interface gateway typ: 80 mA
inside of the modular housing.

Page 14
23SeptMXCat. qxd 11/10/02 11:42 pm Page 15

MX Panel User Interface Modules


OCM800 Operator Control Module
display module to provide a complete panel user Communications: RS-485: RBus Default
interface. In addition the OCM800 can drive up to 9.2Kb
80 inputs/outputs using one of the following Expansion Bus: MINERVA/TFX X-Bus and
MX X-Bus
modules: Legends for LPCB modules: UK/English,
The following I/O and LED annunciator modules Marine,
can be slaved from an MPM800: Dutch,
. Up to 5 x IOB800 (8 in/8 out LPCB/VdS Italian
approved expansion board) Legends for VdS modules: German,
. Up to 5 x XIOM (16 way universal I/O board) Spanish,
Portuguese
. One Mimic Panel (80 way LED mimic driver
PCB)
. One 80 way ANN880 LED mimic Product Codes
The OCM800 is utilised by all MX detection . One 40 way ANN840 LED mimic using red & 557.202.013
panels and full function repeaters to provide yellow LEDs OCM800 with Minerva MX Inserts
mandatory operator control and LED indication . Two 20 way COM820 LED status/command 542.014
functions to comply with EN54:pt.2 and UL864. modules OCM800 with Zettler Expert Inserts
The OCM800 is fully programmable but operates Up to 2 x OCM800 units can be connected to an 557.202.101
in default configurations according to the software MX panel via the internal or external RBus Danish OCM Firemans Keyswitch Assembly
template used. communication port. 557.202.064
Most software templates allow several of the
MX/ZX OCM800 Inserts - Dutch (PK10)
LEDs and control buttons to be programmed for Technical Specification 557.202.065
site-specific functions. The LEDs and control Dimensions: 50H x 232W x 133D mm MX/ZX OCM 800 Inserts - Italian (PK10)
buttons both have slide in legends to suit the Weight: 0.272Kg 557.202.063
default configurations and language. Standard Power Consumption:35mA (Quiescent) MX/ZX OCM800 Inserts - Spanish (PK10)
panels include the appropriate legends for their 36mA (Lamp test) 557.202.066
relevant markets. 81mA (Alarm) MX/ZX OCM800 Inserts - Portuguese (PK10)
The OCM800 incorporates the functionality of an Control Buttons: 7
MPM800, which allows it to drive an operator Indication LEDs: 18

Page 15
23SeptMXCat. qxd 11/10/02 11:42 pm Page 16

OCM800 TO IOB800 CONNECTION DETAILS

ODM800 Operator Display Module


control keys: lists including 95 character
. 0-9 alpha-numeric phone style keypad procedure plus full password controlled
. Up and down scroll keys system manager, service and
. Fast access key for quick access to commonly engineering menu structure
used functions Window 5-Function key legends (eg.
. Five function keys Back, Enter, >>,<<)
The ODM800 is powered and controlled by the Technical Specification
OCM800 operator control module and provides Dimensions: 25H x 232W x 133D mm
various functions according to the panel software. Weight: 0.361Kg
Standard EN54 panels use the LCD display as Power Consumption:50mA (Quiescent)
five windows on the system. 900mA (Alarm Backlit)
Window 1-Details of first detector in 50mA (Alarm during mains
The ODM800 operator display module provides a
alarm failure)
powerful and flexible 40 x 16 character backlit
Window 2-Details of the most recent Product Codes
LCD display used by all MX detection panels and
detector in alarm UK EUROPE
full function repeaters. The ODM800 is used with
Window 3-System Status including 557.202.019 542.019
the OCM800 to provide a fully compliant and
Alarm/Fault and Isolate ODM800 operator display module
approved user interface for UL and EN54 fire
counters 557.202.103
detection panels.
Window 4-Full alarm/event details and Danish ODM 800
The ODM800 also includes the following operator

ANN840 LED Annunciator


The ANN840 is a standard LED annunciator user Technical Specification
interface module which can be driven from an Dimensions: 25H x 232W x 133D mm
OCM800 or an MPM800. The MPM800 can be Weight: 177g
mounted remotely or piggy-backed on the Power Consumption:
ANN840. The ANN840 has removable legends for 1mA + MPM800 (Quiescent)
40 zone status indicators. Each zone can indicate 85mA + MPM800 (25% zones in
RED (eg. Alarm) and YELLOW (eg. Fault & alarm (Alarm))
Isolate). The functionality is programmed in the 340mA +MPM800 (Lamp test)
MX detection panel. Product Codes
The ANN840 operates as 80 outputs (RED & UK EUROPE
YELLOW). 557.202.021 542.021
ANN840 LED annunciator

ANN880 LED Annunciator


The ANN880 is a standard LED annunciator user Power Consumption:
interface module, which can be driven from an 1mA + MPM800 (Quiescent)
OCM800 or an MPM800. The MPM800 can be 85mA +MPM800 (25% zones in
mounted remotely or piggy-backed on the alarm (Alarm))
ANN880. The ANN880 has 80 red LEDs 340mA + MPM800 (Lamp test)
numbered 1 to 80. The functionality is Product Codes
programmed in the MX detection panel but is UK EUROPE
defaulted to zone alarm LEDs. 557.202.022 542.022
Technical Specification ANN880 LED annunciator
Dimensions: 25H x 232W x 133D mm
Weight: 177g
Page 16
23SeptMXCat. qxd 11/10/02 11:42 pm Page 17

COM820 Status Command Module - 20 Way


The COM820 is a standard user interface module, functions
which can be driven from an OCM800 or an . Selective system delay and timer functions
MPM800. The MPM800 can be mounted remotely 2 can be driven from 1 x MPM800.
or piggy-backed on the COM820. The COM820 Technical Specification
has removable legends for 20 status command Dimensions: 25H x 232W x 133D mm
functions. Each function includes a command Weight: 204g
button and a red status LED. The functionality is Power Consumption:
programmed in the MX detection panel. Typical 0.267mA (Quiescent - No LEDs)
applications include: 5mA (Alarm - 25% LEDs)
. Manual/OFF/Auto/Isolate functions for 21mA (Lamp test)
evacuation or plant control Product Codes
. Selective isolate and evacuate functions for UK EUROPE
firemans control 557.202.020 542.020
. Selective plant shutdown and override COM820 Status/Command Module

Input/Output Expansion Cards (XIOM)

The XIOMis a 16 universal input/output


expansion board.
The I/O on the XIOM can be set in banks of 8 to
operate as follows:
. LED driver outputs (10mA source) Technical Specification Product Code
. Relay Driver Outputs (100mA sink) Dimensions: 144H x 85W x 15D mm 557.180.016
. Voltage Monitor Input (8 - 30Vd.c. Normal) Operating Temp: -10 to +65C XIOM MINERVA Input/Output Expansion Module
. Volt Free Contact inputs Storage Temp: -20 to +65C (16 Way)
Relative Humidity: 95% RH (Non-Condensing)
Power Consumption:11mA (Quiescent)
16in - 80mA (Max)
16out - 160mA (Max)
Remote Mimics
the MINERVA MX addressable system. It is Technical Specification
supplied as a single PCB, which may be mounted Dimensions: 235H x 190W mm
in an expansion box or on the rear of a free-
Operating Temp: -10C to +55C
standing panel, as required. It may be used to
drive up to 80 zonal LED indicators, arranged in Storage Temp: -20C to +65C
any configuration, together with two FIRE LEDs, Relative Humidity: Up to 95% RH Non
one FAULT LED and one ISOLATE LED. These Condensing
indicators can operate in the same manner as the Power Consumption:11mA (Quiescent)
corresponding indicators on the panel.
200mA (25% Alarm)
A remote Mimic can be connected to the
800mA (Lamp Test)
MPM800s configured as remote Mimic drivers via
the remote bus. Up to 15 MPM800s may be Product Code
connected on to the remote bus, each with a 557.180.005
The 80-Way Mimic allows custom-made display unique address [set on-board]. The Mimic MINERVA 80 way mimic driver module
and presentation panels to be incorporated in includes audible and visible warning facilities.

Desktop Printer
Features Storage Temp.: -15C to 40C
300 cps draft/ 90cps LQ. Relative Humidity: 10% to 80% RH
Quiet operation [non-condensing]
Lightweight and compact design Operating Voltage: 180V to 264Va.c.
9 LQ fonts
EMC: BS EN 50081-1 and BS EN 50082-1
2 paper feed paths
Convertible push/pull tractor Product Codes
Paper guide UK EUROPE
Auto loading 557.180.239
Paper park MINERVA printer LQ-300+
Cable feed recess
Epson LQ standard terminal emulation 557.180.220
available LQ80 ribbon black (spare) for use with desktop
Parallel and serial interface printer.
The printer is designed as a low cost business Technical Specification 557.202.117 542.009
printer ideally suited for mounting adjacent to the Dimensions: 159H x 366W x 275D mm
fire control panel.The LQ-300+ combines high MX FIM/MPM to serial printer lead
Weight: 4.4kg
performance with paper handling flexibility and
quiet operation. Operating Temp.: 5C to 35C
Page 17
23SeptMXCat. qxd 11/10/02 11:42 pm Page 18

In-built Printer
Features Product Codes
. A thermal printer mechanism which ensures 557.202.024
high reliability. PRN 800 Printer c/w front cover module
. Quiet Operation 557.301.014
. Lightweight and Compact Design Spare Paper Roll (pk of 5)
. High Speed Printing: 40mm per second.
. High quality printing: 384 dots.
. 32 Columns
. Friction paper feed

Technical Specification
Dimensions: 230H x 137W x 85D mm
The PRN800 Printer Kit is designed for use with
the designer range of MX Controllers (MX1000, Weight: 0.38Kg
MX4000 and T2000). It is fitted to the front cover Operating Temp: +5C to +45C
of the MX battery housing and is powered from Storage Temp: -20C to +70C
the PSB 800 power supply via an FB800
Relative Humidity: Up to 80% non-condensing
fuseboard in the MX Controller housing.
EMC: BS EN 50081-1 for emissions
BS EN 50082-1 for immunity

Remote LCD Display


Features Operating Temp: -10 C to +55 C
. Uses a backlit 4x20 character alphanumeric Relative Humidity: Up to 95% RH Non-
display. Condensing
. Provides an internal log of up to 150 events. Power Supply: 200mA @24Vd.c.
. Provides internal audible warning of an event. Ext. Sounder Relay: 500mA@24Vd.c.
. Allows the event log to be scrolled. EMC: Product Family Standard
. Local internal buzzer silence. EN50130-4 in respect of Conducted
Disturbances, Radiated Immunity, Electrostatic
. Connects to host panels RS232 port (maximum
Discharge, Fast Transients and Slow HighEnergy.
cable length between panels and first repeater of
EN50081 -1 for Emissions.
15m).
Product Codes
. Provides an external sounder to mimic the
internal buzzer. 557.200.024
. Can be connected to an unlimited number of Remote LCD Repeater (compatible with Version
other LCD Repeaters by using the RS232/RS422 2.1 and above)
The Remote LCD Repeater Module is designed to
provide an independent scrolling log of system converter (Up to 1200m between repeaters). 557.202.117
status at numerous points within a building or The LCD repeater must not be used in the MX Printer Lead
site. The module interfaces directly to a serial primary fire path. It must not be used as the sole 557.180.152
printer port of the MX addressable fire panel. If a warning that a fire exists.
9-Way gender changer
local printer is already connected to the Panels
MPM800 serial port, a second MPM800 must be 557.180.151
Technical Specification:
used. RS232/422 converter for LCD Repeaters.
Dimensions: 150H x 200W x 75D mm
Material: Bayblend polycarbonate/
ABS alloy

Cables & Other Modules


Product Codes 557.201.306 542.053
UK EUROPE Standard MXExpansion backbox and chassis
557.201.300 542.047 plate
BFP801 Spare blank user interface module 557.201.310 542.049
557.202.116 542.008 Deep MXExpansion backbox and chassis plate
FIMModem lead 557.202.113
557.201.305 542.052 PSB to FIM Cable
Designer door complete with hinges and brackets
557.201.301
Standard MX Panel designer backbox and
chassis plate
976254 542.031
Set of spare keys for MX Panel
557.201.302 542.049
Deep MXDesigner backbox and chassis plate

Page 18
23SeptMXCat. qxd 11/10/02 11:42 pm Page 19

MX Graph/MXNet
MXGraph
zoom magnifications are all imported from MXGraph can be connected to up to 99
AutoCad. This configuration tool significantly networked MX fire panels using the LPCB
reduces configuration time, increases the integrity approved MXNet. MXGraph will also be available
of information and enables simple updates to the for use with up to 64 MX fire panels networked
using the LON based VdS approved FILNET.
system in the future.
MX net will support up to 3 fully operational
Features MXGraph user interfaces on a network plus
Combined text and graphics display on a additional units operating as graphical mimics.
single P.C. MXGraph consists of a standard personal
Connected to MXNet, a single system can be computer, that is linked onto the MXNet via a TLI-
used to monitor up to 99 MX fire controllers 800 network interface module. MXGraph is
primarily operated by either mouse or touch
Designed for touch screen operation screen, with the two monitor options available
Simple operator controls, no Qwerty keypad 17or 22touch screen.
High resolution colour SVGA display
For an up to date specification of the latest
Windows NT TM multi-tasking operating system approved PC platform, contact the Fire Product
Four level automatic zoom sequence available Manager.
Introduction for each point
MXGraph is a fully integrated graphical and text Overview map maintains a view of wider areas Product Codes
user interface for use with MINERVA MX , whilst zooming into detail in the graphics 508.020.007
ZETTLER EXPERT and MINERVA T2000 window
Compatibility tested PC for MX & ThornGraph
networked fire panels. Procedure window provides additional text
graphics terminal preloaded and configured with
and operator instructions for each event
Whether the installation uses a single sub-panel default passwords
Classification of events helps to maintain a
or up to 99 networked sub-panels, MXGraph 508.020.006
record of activation and the causes
provides a seamless integrated graphical mimic 22 inch IIyama Touch Pro
Browse icons placed on maps can be used to
with full alarm management and panel control pan across an installation in a logical 636.006.060
capability. sequence 17 inch Standard monitor
MXGraph has been designed with clear displays Control icons placed on maps can be used to 508.020.201
and simple controls which can be quickly and initiate actions at the MX fire controller, used to Software package A for 1 network node
easily understood by an operator rather than an operate ancillaries such as HVAC
engineer. The system is designed to be used with 508.020.202
Automatic configuration using the GRAB-IT
a touch screen or mouse and does not require Software package B for 2-5 network node 5
tool, including Cad drawings, text messages,
the use of a Qwerty keyboard. locations, flood fills and zoom areas 508.020.203
Using the secure acknowledged transfer of Full password protection and multiple operator Software package C for 6 or more network nodes
events, up to three MXGraph systems can be levels 508.020.204
used to monitor up to 99 MX controllers Remote control of MX fire controller across the Software package D for additional graphics nodes
connected to an MXNet. network on the same MXNet
MXGraph uses a unique configuration tool GRAB- Real time on line event management and MXGraph is functionally similar to Thorngraph.
IT, (Graphical, AutoCad, Bitmap, Information, historic information system For full details of upgrade paths contact the Fire
Transfer) to automatically configure the system. User designed search keys can be used to Product Manager.
Installation plans, device type and location, flood generate specific and useful reports
fill areas, flood fill locations, zoom areas and Available in English, Dutch and Spanish

MXGraph Typical Arrangement

Max distance between Max distance between


nodes is 1000m using nodes is 3000m using
MICC cable twisted/shielded pair
cable

TLI800

Network
Interface

TLO530 TLO530
Fibre
Fibre
Interface
Interface
Max distance between
nodes is 4000m using
fibre optic cable

Page 19
23SeptMXCat. qxd 11/10/02 11:42 pm Page 20

MXNet & ThornNet


ThornNet is a high integrity LPCB approved peer Features MX controllers may be grouped into sub-nets
to peer communication network which has been LPCB approved where each panel is programmed to inter-act
tried and tested over 1000 major fire detection only with other selected controllers.
A peer to peer network that does not use a
installations around the world. host or master controller. Plug-in module (TLI-800) easily connects an
This network is now also available as MXNet for MX fire controller to the network.
99 nodes, 99,000 points, 23,760 zone
networking MX panels together. For use with MX capacity. Data is re-generated at each MX controller and
panels ThornNet has been enhanced to allow up is sent out over the MXNet as new clean data.
Bi-directional signaling.
to 99 nodes on a network and to carry new types All degradation in received data due to noise
Open/short circuit isolation. on a line, line attenuation, or phase shifting is
of message.
Events originating at any node can be used as eliminated when the data is re-generated.
This enhanced network retains all the features
an input to event/action processing of other The MXNet uses a token-passing, non
and resilience of ThornNet and uses all the same panels to co-ordinate and distribute systems
hardware and cabling. collision communication protocol for data
control. transmission.
MXNet provides a true peer to peer System can be configured in the field using "Network zones" and "sectors" allow the
communications interface for up to 99, MINERVA MX Consys software. network controllers to be configured as a
MX, ZETTLER EXPERT or MINERVA T2000 fire single "seamless" system.
Failure of one node does not affect any other
controllers in any combination and the MXGraph, node or communications between nodes. In MXGraph, a P.C. based graphical user
graphical user interfaces. The units can be inter- the event of multiple failures, nodes will interface, connects directly on to the network.
connected into a large network without the need automatically re-generate into independent
for a host or master controller. MXNet is based MXNet supports combinations of MICC,
fully functional networks.
upon a combination of hardware and software twisted/shielded pair cabling, fibre optic
Automatic network re-configuration when a cabling, and dedicated telephone line.
that allows MX fire controllers (Nodes) to be previously failed node is restored to the
linked together. The MXNet supports up to 99,000 Multiple communication topologies bus or
network.
analogue/addressable points and over 49,000 ring.
Up to 3,000 metres between nodes with
digital I/0 points. The network co-ordinates and twisted/shielded cable.
distributes alarm annunciation and supervises See separate documentation for full details of MX-
System will operate on standard 2 core MICC. FILNET, VdS approved networking alternative to MXNet.
system operation. When connected to the
network, each MXFire controller maintains its full
stand-alone features, functions and capabilities.

TLI-800
The key hardware component that makes the
network possible is the LPCB & UL approved
network card TLI-800. The TLI-800 provides the
electrical/mechanical means to connect the
components of the network to local and remote
network signalling circuits. Installation of the TLI-
800 is simplified with an edge connector that
plugs onto the main processor board of the MX
controller. The TLI-800 provides RS-485
communications over a twisted shielded pair as a
standard configuration. The distance between
controllers can reach 3,000 metres at a speed of 557.200.038
38.4 Kbs using 18AWG twisted shielded cable. 557.202.026
TLI-800G ThornNet interface for MXGraph PC c/w
It fits within the MX panel housing. Later versions TLI-800 MXNet network node interface module 240V PSU and housing
of the MX Panel software will be compatible with 557.180.219
ThornNet and TFXNet. This uses the TLI/TLK530 NOTE: TLK-530 and TLK530-G can be upgraded
to TLI-800 and TLI-800G with a firmware change. MXGraph PC to TLK-530-G & TLI-800G
network or the TLI-800 with different firmware. connection cable
TLO-530
The Fibre Optics Module (TLO-530) is used to Up to two units can be fitted into a TLO/TLD
interface one fibre optic channel to the TLI-800 Housing which has a chassis plate to
module. The TLO - 530 fibre optic interface accommodate the units.
module converts RS-485 digital data current Technical Specification
pulses from the TLI-800 network interface module
Dimensions: 210H x 130W x 30D mm
to light pulses. The light pulses are then carried
over fibre optic cabling to another TLO-530 where Weight: 460g
the pulses are converted back to RS-485 digital Product Codes
data current pulses. Two TL0-530 modules are 976166
required per panel for redundant path star
TLO 530 ThornNet/MXNet fibre optics interface
connections and when using fibre optics in both
assembly
directions of ring and bus connections. Two (2)
type 62.5/125 fibres between controllers (4 fibres 557.180.148.A
when using redundant path star connections) TLO/TLD Housing - ADT branded
allow the interface to transmit signals at 38.4 Kbs
at distances as high as 4,000 metres between
controllers.

TLD-530
The Telephone Line Drive Module (TLD-530) is Technical Specification
used to interface two (2) dedicated telephone line Dimensions: 170H x 120W x 20D mm
circuits to the TLI-800 module. The TLD-530 line Weight: 140g
driver module converts the RS-485 signals Product Codes
received from the TLI-800 network interface 557.180.699
module to signals capable of being transmitted TLD 530 ThornNet/MXNet direct line driver PCB
over the telephone line circuits. One TLI-800
557.180.148.A
supports two channels so only one module is
TLO/TLD Housing - ADTbranded
required per controller for both single path and
redundant path star connections. The interface
allows for field configured baud rates and
supports distances of up 3,000 metres. Up to two
units can be fitted into a TLO/TLD Housing.
Page 20
23SeptMXCat. qxd 11/10/02 11:42 pm Page 21

MINERV A Solo Detection Panels


557.300.004 542.096
The MINERVA SOLO universal loop card currently MXS 16R Minerva Solo Full Function 16 Zone
supports the following protocols: Repeater
. Apollo Series 90, XP95 and Discovery protocols 557.301.007.P
. Hochiki ESP protocol MXS Loop Card for use with Apollo protocol
. Nittan AS protocol 557.301.007.H
MXS Loop Card for use with Hochiki protocol
Technical Specification 557.301.007.N
Dimensions: 320H x 440W x 120D mm MXSLoop Card for use with Nittan protocol
Approx Weight: 7Kg (without batteries) 557.301.005
Temp. (Storage): -10 to +55 oC MXS/PRN Panel Mount Thermal Printer
Temp. (Operating): -10 to +40 oC 557.301.011
Humidity: 0 to 95% RH MXS CPU to printer lead
EMC/RFI: EN 50130-4 557.301.014
Shock: EN54-2 Spare paper for Panel Mount Thermal Printer (pk5)
Vibration: EN54-2 557.301.102 542.105
Colour: Dawn Grey Pantone Qwerty Keyboard for programming text descriptions
Features (BS4800 10A-03) into Minerva Solo.
. Single MX DIGITAL loop 8 to 16 zone detection Outputs: 5 Monitored outputs 542.107
panel 5A@24Vd.c. Zettler Solo TU Module
. LPCB approved to EN54:pt.2 and pt.4 Repeater Bus: RS485 Max. 1.2Km 542.095
. Auxiliary loop power Max.16 repeaters MXS 16 Zettler Solo two Loop 16 Zone Panel
. MX VIRTUAL detectors Approvals (pending): EN54:2
. Fully programmable with front panel EN54:4
programming option Loop power: 495mA (standard MX loop
. Optional integral event printer card)
. 2 x 40 Character text display Battery Capacity: Up to 12Ah (internal)
. Pre-alarm functions Up to 17Ah (external)
. Display of temperature, CO and smoke levels
. Supports day/night detection modes Product Codes
. Supports MXSOLO Remote diagnostics UK EUROPE
. Optional full function repeaters 557.300.001
. Optional service upgrade universal loop card MXS 8 Minerva Solo One Loop 8 Zone Panel.
557.300.002 542.094
The MINERVA SOLO use Tyco MX technology to MXS 16 Minerva Solo One Loop 16 Zone Panel
provide a highly featured yet cost effective fire 557.300.005
detection panel. MXS8 Minerva Solo One Loop 8 Zone Panel (Flush)
The MINERVA SOLO is a single loop LPCB approved 557.300.006
EN54 detection panel available in 8 and 16 zone MXS16 Minerva Solo One Loop 16 Zone Panel (Flush)
models. 557.301.006 542.106
MINERVA SOLO panels provide a highly featured and Minerva Solo MX Loop Card (Spare)
fully approved alternative to conventional detection 557.301.101 542.104
systems in small to medium multi-occupancy, Solo Consys-Configuration Software Key for
commercial and industrial buildings. The MINERV A MX/Apollo/Hochiki/Nittan Protocol
SOLO also allows systems with existing addressable 557.301.012
detectors to be upgraded to the latest panel Programming Lead for connecting a laptop to the
technology and benefit for the service and central Minerva Solo
station monitoring offered by Tyco companies. 557.300.003
MXS 8R Minerva Solo Full Function 8 Zone Repeater

Solo Detection Panel System Schematic


Loop back
to panel Max 1.2Km

220-240Va.c.

24V.d.c. 24 Vd.c.

Callpoint

MXS 8/16
MSR Repeater MSR Repeater

Fire output
Fault output
PIM CIM
Sounder 1
Sounder 2
Aux. output
MIM
557.301.005 SNM
MSPPrinter

MX Virtual Sounders
Detector
557.301.012
Programming Lead
DIN
557.301.102
Keyboard Callpoint

DIM

ASCII Qwerty Keyboard


Conventional
Detector

Laptop

SOLO Remote

Page 21
23SeptMXCat. qxd 11/10/02 11:42 pm Page 22

Batteries
Product Codes 3071 560.001.016
660.001.003 Battery sealed L-A replaces 660.001.009 and Battery sealed L-A replaces 3148, SLA17 and
Battery sealed L-A 30-105 30-109
560.001.013 660.002.010 660.001.004
Battery sealed L-A replaces parts 3145 and Battery sealed L-A replaces 3146, SLA04 and Battery sealed L-A (Bolt terminal) replaces 3014,
30-102. 30-112 SLA24 and 30-106
3085 3072 560.001.012
Battery sealed L-A replaces 660.001.014 and Battery sealed L-A replaces 660.001.005, SLA07 Battery sealed L-A replaces 3149, SLA38 and
30-111 and 30-110 30-107
3010 660.002.012 3150
Battery sealed L-A replaces 660.001.007, SLA21 Battery sealed L-A replaces 3147, SLA012 and Battery sealed L-A replaces SLA65 and 30-108
and 30-103 30-110

Product Codes Model No. Voltage (V) Ah Dimensions (mm)


Length Width Height
660.001.003 NP1.2-6 6 1.2 97 25 54.5
560.001.013 NP10-6 6 10 151 50 97.5
3085 NP1.2-12 12 1.2 97 48 54.5
3010 NP2.1-12 12 2.1 178 34 64
3071 NP2.8-12 12 2.8 151 50 97.5
660.002.010 NP4-12 12 4 90 70 106
3072 NP7-12 12 7 151 65 97.5
660.002.012 NP12-12 12 12 151 98 97
560.001.016 NP17-12 12 17 76 180 165
660.001.004 NP24-12B 12 24 175 166 125
560.001.012 NP38-12 12 38 179 165 170
3150 NP65-12 12 65 350 166 174

Page 22
23SeptMXCat. qxd 11/10/02 11:42 pm Page 23

MX VIRTUAL Multi-Sensor Detectors


Key Features
Construction & Technical Specification
The 800 Series detectors are supplied in an
extremely robust and reliable fully sealed
construction, which has undergone stringent
environmental and Marine type testing. All
electrical contacts are moulded into the plastic to
eliminate any movement.
The detectors are constructed from hardwearing
Fire Resistant FR110 plastic.
The multi-sensor detectors are environmentally
friendly. They use no radioactive parts and can be
returned to the factory for recycling at the end of
their life.
All 800 Series detectors are supplied with integral
dust covers as part of the packaging. Dust covers
are retained throughout installation and removed
at commissioning time.
Unique design of the 801PH optical chamber
provides immunity to thrips and other small
insects without the need for metal gauze.

Introduction & Key Features


The 800 Series are addressable multi-sensor fire, . Detector Service functions allow 800 Series
smoke and heat detectors, which can be detectors to be automatically addressed
implemented as several MX VIRTUAL detectors by . Full range of remote installation and service
the MX detection panel. tools
The 801 and 811 Series are designed and . Dirty Detector Read-out can be viewed on the
approved to EN54, the 801 Series carry land MX SERVICE tool or panel.
based approvals and the 811 Series also carry . Serial Number and Manufacturing data is also
Marine approvals. available from the MX SERVICE tool.
The 812 Series are designed and approved to UL
specifications and the 814 Series to Australian Technical Specification
SSL specifications. Dimensions: Dia 109mm /43H mm
The 800 Series of MX VIRTUAL detectors provide (54mm with standard base)
the latest fire detection technology in an attractive Weight: 0.124kg (Detector only)
cost effective package. 0.192kg (Detector/Std Base)
Key Features Power Consumption:150A (Quiescent)
. Over 20 Fire Detection modes 2 to 5mA (Alarm)
. Tyco MX FASTLOGIC Expert Algorithms Loop voltage: Min. 20.0V/Max. 37.5V
. MX HPO detection algorithms (MX Digital)
. Tyco CO fire detection technology LED: Single red LED (function
. Up to 250 detectors per loop programmable)
. Optional bi-directional line isolation with every Material: Body, cover and base
detector FR110 BAYBLEND Fire
. Remote detector verification & temperature Resistant
read-out Temp. Measurement: Accuracy +/-0.25 oC
. Highly featured MX SERVICE tool Resolution 2oC
. Programmable Alarm LED with 360 o viewing Operating Temp.: See specific detector
angle Storage Temp.: See specific detector
. Optional detector locking pin Relative Humidity: 95% non-condensing
. Variety of sounder and relay detector bases Shock/Vibration/Impact: prEN54:pt.7
. Address flag stays with the base Corrosion: prEN54:pt.5 and prEn54:pt.7
. Internationally approved EMC/RFI: EC Directive 89/336/EC
Installation & Service Features Outputs: Remote indicator & control
The 800 Series MX VIRTUAL detectors include a output for relay and sounder
host of installation and service features which bases
are provided to reduce installation and service Internal memory: Total 128 bytes / 32 bytes
costs and reduce repair times. for service information
. Standard and 6 bases with multiple mounting including:
options speed and simplify installation - Detector dirty level
. Unique park position for commissioning and - Date of manufacture
service procedures. - Date of commissioning
. Detector Addressing programmed from the MX - Address
SERVICE Tool or MX Panel - Event history etc.
. Address flag fixed to the base to prevent mix
ups during service
. Compatible with Tyco 600 and 900 Series
bases for easy upgrade
. Panel Auto-Config and Self learn functions
supported by the detectors

Page 23
23SeptMXCat. qxd 11/10/02 11:43 pm Page 24

Detection Modes
All 800 Series detectors communicate to the MX to operate in one or two of several detection To meet detection applications with multiple risks
detection panel using the fast reliable MX modes, thus allowing it to be easily optimised to the 800PH and 800CH detectors allow two
DIGITAL loop protocol. This allows each detector the risk. detection modes to operate simultaneously.

Virtual Detectors
The use of virtual detection means that Some MX detection panels even allow the reduced by reducing manufacturing, stocking and
installations can change the detection mode detection mode to be changed at different times service stocks. This also reduces the number of
without any physical change, taking place. Not of the day or automatically as occupancy and times detectors have to be changed during the
only can the detection be changed at the time of activity in the space changes. life of the installation.
installation and commissioning but also during As well as providing great flexibility, using only
the life of the building as building usage changes. two detector models means whole life costs are

The 800PH Series support the The 800CH Series support the
following detection modes following detection modes:
incorporating MX FASTLOGIC expert . Multi-sensitivity Carbon Monoxide
algorithms: . Temperature Enhanced CO (CCO)
. Multi-sensitivity Optical . Fixed temperature heat
. Temperature compensated . Rate-of-rise heat
optical (HPO)
. Fixed temperature heat
. Rate-of-rise heat

To complete the range the The 800I Series of


800H heat only detectors ionisation detectors are also
support fixed heat, rate-of-rise available for some markets.
and high temperature detection
modes.

800PH Multi-Sensor Smoke and Heat Detectors


The 800PH is a state-of-the-art smoke and heat addition a unique chamber cover actually draws
detector which allows a full set of detection slow moving smoke into the chamber to provide a
modes to be implemented in the MX detection more responsive detector. The unique design
panel to suit most smoke and heat detection provides immunity to small insects and thrips
applications. without the need for a separate thirp filter.
The 800PH incorporates a unique mousehole The 800PH provides all the features of MX
design optical chamber with an unrivalled signal VIRTUAL detectors including self verification,
to noise ratio providing high resilience to dust temperature and smoke level indication and
and dirt which means reduced service costs. In unrivalled service functions.
801PH 811PH Technical Specification
Optical Yes* Yes* Dimensions: 109dia x 43H mm
Enhanced Optical (HPO) Yes* Yes* Operating Temp.: -20 to +70 oC
Normal Ambient ROR A1R A1R Storage Temp.: -40 to +80 o C
Fixed Heat A2S 60o C A2S 60oC Relative Humidity: 95% (non condensing)
Certification LPCB/VdS Marine Standards: prEN54 pt 5, prEN54 pt 7
* Approved with MX Fastlogic algorithms
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801PH 516.800.500.A 516.800.500.T 516.800.500.W 562.000 516.800.500.Y
811PH 516.800.507

Page 24
23SeptMXCat. qxd 11/10/02 11:43 pm Page 25

800CH Multi-Sensor Carbon Monoxide Fire Detectors


The 800CH is a state-of-the-art carbon monoxide mean that CO detection alone would be
and heat detector which allows a full set of insufficient.
detection modes to be implemented in the MX The 800CH incorporates a reliable electro-
detection panel to suit most fire and heat chemical CO detection cell and high specification
detection applications. The 800CH is particularly low thermal mass thermistor for accurate
well suited to sleeping risks, storage areas and temperature detection.
applications where smoke detector positioning is The 800CH provides all the features of MX
difficult or where smoke detectors are prone to VIRTUAL detectors including self verification,
false alarm. The integration of heat detection into temperature and CO level indication and
the 800CH allows the detector to operate in a unrivalled service functions.
wide variety of applications where combined risks
801CH 811CH Technical Specification
Carbon Monoxide Yes Yes Dimensions: 109dia x 43H mm
Enhanced CO (CCO) Yes Yes Operating Temp.: 0 to +55o C
Normal Ambient ROR A1R A1R Storage Temp.: -20 to +55 oC
Fixed Heat A2S 60oC A2S 60 oC Relative Humidity: 95% (non condensing)
CCO plus ROR (A1R) Yes Yes Standards: prEN54 pt 5
Certification LPCB Marine prEN54 pt 7

Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801CH 516.800.501.A 516.800.501.T 516.800.501.W 562.001 516.800.501.Y
811CH 516.800.508

800H Heat Detectors


The 800H is a flexible cost-effective addressable Dimensions: 109dia x 43H mm
heat detector with all the features of MX VIRTUAL Operating temp.: -25 to +70 o C(-40 to +90oC
detectors. The 800H returns the temperature to for short periods)
the MX detection panel which allows various Storage temp.: -40 to +80 o C
detection modes to be implemented. The 800H Standards: prEN54:pt.5
uses a high quality thermistor with very low
thermal mass. This allows the detectors to 801H 811H
provide fast accurate temperature detection as High Ambient ROR CR CR
well as heat detection. Normal Ambient ROR A1R A1R
Fixed Heat A2S 60o C A2S 60 oC
Technical Specification Certification LPCB/VdS Marine
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801H 516.800.502.A 516.800.502.T 516.800.502.W 562.002 516.800.502.Y
811H 516.800.509

800I Ionisation Smoke Sensors


The 800I ionisation detectors are offered for old Technical Specification
specifications which still call for ionisation smoke Dimensions: 109dia x 43H mm
detectors. The 800CH and 800PH detectors offer Operating Temp.: -20 to +70 o C
improved performance, significantly lower false Storage Temp.: -40 to +80 oC
alarms and environmental compatibility for smoke Relative Humidity: 95% (non condensing)
detection applications. The 800I nevertheless Standards: prEN54 pt 5
offers state-of-the-art ionisation smoke detection prEN54 pt 7
with self verification, smoke level indication and
threshold compensation for detector condition
monitoring. The 801I is LPCB approved.
Product Codes
Branding ADT THORN WORMALD ZETTLER TYCO
801I 516.800.515.A 516.800.515.T 516.800.515.W NA 516.800.515.Y

Line Shorting Adaptor


Product Codes
517.050.002.A
Low profile line shorting adaptor commissioning tool (shorts terminals together enabling cable
resistance checks to be carried out) - ADT Branded
562.004
Low profile line shorting adaptor commissioning tool (shorts terminals together enabling cable
resistance checks to be carried out) - Zettler Branded

Page 25
23SeptMXCat. qxd 11/10/02 11:43 pm Page 26

Detector & Mode Selection & Design Charts


Detector Selection Chart
This chart is designed to assist with the selection of the best detector for the risk.
1. First select the environment
2. Next select the fire loading or risk being protected.
The corresponding square shows the best suited (bold) and other suitable detectors for the application.

Page 26
23SeptMXCat. qxd 11/10/02 11:43 pm Page 27

Detector Mode Selection Chart


This chart is designed to assist with the selection of the best detector mode to be implemented during system configuration.
Once the most suitable detector has been selected (see detector selection chart on previous page) this chart can be used to find
the best detection mode for occupied (day) and unoccupied (night) applications.

E = Temperature enhanced Bold text indicates most likely detector/mode to meet users
E+H = Temperature enhanced and heat detector together requirements.
H = Heat only part of combined detector Letters in brackets represent recommended sensitivity settings.
X = Callpoint protection alone *Not available as part of 800 range.
#Not LPCB approved
Table is for guidlines only and specific situations are likely to require variations on the suggested detector types. Real situations may require detector combinations to
cover all likely risks.
Night and Day columns represent low false alarm risk and high false alarm risk, although this usually follows a day/night pattern, it may be configured for any time.
For example the car deck of a ferry would be configured for Day during vehicle loading and Night once all the passengers had left the car deck, thus achieving
optimum protection for that area.
If fastlogic operation is selected for optical detectors, the same table applies. The chief difference being a higher resistance to false alarms, and slower response to
aerosol test gas.

Page 27
23SeptMXCat. qxd 11/10/02 11:43 pm Page 28

Tyco MX Virtual Detector M800 Series Identification Card


A convenient pocket sized Quick reference card
designed to aid the identification of Tyco MX
Virtual Detectors.

Product Code
AM2801/000
ID Card
Note: Cards must be ordered in multiples of 100.

800 Series MX Detector Bases and Ancillaries


Features beyond the detection technology itself. The range
. 4 and 6 detector bases of detector bases is designed to make low profile
. Optional short circuit isolator in each base detector installations cost effective, aesthetically
. Optional relay bases pleasing and easy to install and maintain thus
. Loop powered sounder bases minimising disruption.
. Remote indication LEDs The detector bases include standard universal
. Standard and stainless steel duct probes bases, which have no integral electronics, thus
. Optional conduit entry backboxes making them low cost and low maintenance.
. Detector locking pins Alternatively, a range of functional bases
. Protective wire cages incorporates sounders, relays and line isolators to
The 800 Series of MX VIRTUAL low profile provide a cost effective method of adding
detectors provide a comprehensive range of functions and flexibility to the fire detection
highly effective and aesthetically pleasing fire, installation.
smoke and heat detectors with worldwide Duct probe units are specially designed to enable
approvals. optimum performance even at low air velocity and
The unique design and leading edge technology are also available in stainless steel.
of the 800 Series MX low profile detectors goes

Standard Universal Bases


The standard universal detector bases are compatible with new 800 Series MX detectors as well as the M600 and M900 Series low profile detectors. The
standard bases have no electronics and even when the detectors are connected to the bases, they can be electrically disconnected and left in a park
position. This enables wiring integrity tests to take place without any damage to electronics. When used with 800 Series MX VIRTUAL detectors the address
flag automatically transfers to the base, thus the address remains with the base even if the detector is changed or replaced. An optional, tool removable
locking pin allows the detector to be fixed in place to prevent tampering.

Minerva Universal Base (MUB)


This is the most common base designed to fix Product Codes
directly to the ceiling or various common 517.050.001
backboxes including the 800EM for 18 and 21mm MUB standard 4 base (UK/Marine)
conduit entry and the DHM69 sealed deck head 571.070
mount. This base allows a detector to be plugged MUB standard 4 base (EUROPE)
in directly or a functional base to be plugged in
between the base and detector.
Features
. Variety of fixing options
. Remote LED connections
. Anti-tamper facility
. Park position and address flag holder

801IB - 4 Isolator Base


circuit isolation. Implemented on every detector Product Codes
the 801IB can ensure that no detector is lost on a 516.800.903
system in the event of an open or short circuit. 801IB isolator base (UK/Marine)
Alternatively the 801IB can be implemented 572.033
between zones to provide short circuit isolation 801IB isolator base (EUROPE)
according to BS5839:Pt.1 and EN54. The 801IB (Consult technical publications for details and
can be used as a stand-alone line isolator fitted number of devices between isolators.)
between callpoints and other ancillaries.
Features
. All the features of MUB
. Up to 250 per MX DIGITAL loop (refer to
technical publications for design parameters)
With all the features of the MUB the 801IB isolator . Isolation upstream and downstream
base allows any or all 800 Series MX detectors to
be upgraded to incorporate bi-directional short

Page 28
23SeptMXCat. qxd 11/10/02 11:43 pm Page 29

6B - 6 Universal Base
Especially designed for applications using the US Features
style single gang backbox the 6 base provides . Waterproof gland protects the detector from
an attractive styled alternative to the 4 base in water ingress from the rear
most applications. The 6 base is particularly . Remote LED connections
useful for retrofit applications where large holes . Anti-tamper facility
left by previous installations cannot be covered by . Includes blanking pieces for mounting holes
the 4 base. Product Codes
517.050.606
6B-6 detector base (UL)

Functional Detector Bases


Functional detector bases use a common moulding which incorporates a double sided circuit board which enables electrical connections to be made on the
top and bottom of the functional base. This allows the functional bases to be retrofitted into new and existing universal bases or alternatively using the
functional base instead of the universal base can reduce the depth and cost of the installed detector. This feature enables additional sounders to be easily
added during commissioning. In addition changes to the building during its life can be easily adapted to, by retrofitting sounders and relay outputs to
existing detection points.

801SB Loop Powered Addressable Sounder Base


panel. This allows the 801SB to sound when its Product Codes
own detector is in alarm or as a zonal sounder. UK EUROPE
The number of 801SB per loop depends on the 516.800.907 572.029
volume and loop power available. 801SB loop power sounder base
Features Note: For detailed design guidelines on loop
. 3 selectable tones (slow , fast and continuous) powering ensure that Technical Publications are
. 3 volume settings (90, 80 and 70dB effective) consulted.
. single point sound source
. standard MINERVA frequency
. complies to prEN54:pt.3
. Loop current consumption at full volume -
The 801SB sounder base operates with all 800 15mA
Series MX VIRTUAL detectors. A unique design . 24V Current consumption at full volume -
single point sound source is used to provide 25mA
complete audio coverage without obtrusive holes
in the moulding. The 801SB is controlled by the
powerful event action of the MX fire detection

Tyco MKII Sounder Bases


A new low current range of sounder bases for use Product Code
with the MX Fire Alarm Control Panel. 516.800.910
802SB MX Loop Powered Sounder Base
516.800.913
Features
812SB Loop Powered UL Sounder Base
Manufactured to EN54 part 3 516.800.911
Integral sounder and detector base 901SB Universal Sounder Base
Volume and tone adjustable after installation 516.800.912
Low Power Synchronisation 912SB Universal UL Sounder Base
Do not require use of a standard base (maybe
installed directly onto a standard besa box)

Please See Following Applications Table for


Further Details.

SAM 800 Sounder Addressable Module


The SAM 800 Sounder Addressable Module is an Product Code
MX addressable device which may be fitted to the 516.800.954
801SB, 802SB, 812SB, 901SB and 912SB SAM 800 Sounder Addressable Module
Sounder Bases to enable the MX Control Panel (compatible with Version 2.1 and above)
to communicate with and control these sounder
bases, without the need for a detector effectively
turning the 801SB, 802SB, 812SB, 901SB and
912SB into an addressable loop powered
sounder.

The SAM 800 is suitable for wall or ceiling


mounting. Sound selection and tones will be as
per the 801SB, 802SB, 812SB, 901SB and
912SB.

Page 29
23SeptMXCat. qxd 11/10/02 11:43 pm Page 30

SAB 800 Sounder Addressable Beacon


The SAB 800 Sounder Addressable Beacon is an per the 801SB, 802SB, 812SB, 901SB and
MX Addressable Beacon that fits into the 912SB.
Standard Minerva Universal Base. Alternatively
the SAB 800 may be fitted to the 801SB, 802SB, Product Codes
812SB, 901SB and 912SB Sounder Bases to 516.800.953
enable the MX Control Panel to communicate with SAB 800 Sounder Addressable Beacon
and control these sounder bases and also (compatible with Version 2.1 and above -
provide a Flashing Beacon effectively turning the available December 2002)
801SB, 802SB, 812SB, 901SB and 912SB into a
combined addressable loop powered sounder
and beacon.

The SAB 800 is suitable for wall or ceiling


mounting. Sound selection and tones will be as

801RB - Functional Relay Base


The 801RB provides dual relay contacts for Features
signalling external devices on MX addressable . Dual pole 24V DC relay contacts (60VA)
systems. A very low operating current even when . Status indication LED
the relay is energised enables the relay base to . Very low power consumption (<20A except
be used without any additional power. The dual startup)
contacts are under the control of a programmable
output, through the powerful cause and effect Product Codes
software. UK EUROPE
516.800.905 572.028
801RB Relay base

Volume Adjustment Tool


A simple Volume Adjustment Tool, specific to the
task of sounder volume selection on the variable-
volume range of Tyco MKII Sounder Base
Devices.
Product Code
517.050.015
Sounder volume can be easily varied between the
maximum 90dBA and minimum 68dBA-volume Volume Adjustment Tool
settings, using this simple, functional tool.

Note: Sounder Base Devices are supplied with


the volume pre-set to maximum volume.

Detector Ancillaries
800 Series MX Address Flag
The 800 Series detectors incorporate a feature, Product Codes
which automatically transfers the address flag to 516.800.915
the detector base, when the detector is plugged MXAddress flags (pack of 100)
into the base. On removal of the detector the 516.800.931
address flag remains on the ceiling, thus ensuring Address flag labels Loop A - White
that detectors are not accidentally returned to the 516.800.932
wrong detector base following service routines. Address flag labels Loop B - Yellow
Most MX detection panels incorporate additional 516.800.933
fail safe software features to ensure that incorrect Address flag labels Loop C - Purple
detector positioning does not compromise the 516.800.934
system. Address flag labels Loop D - Green
Address flags are supplied in packs of 100.
Labels are provided on sheets of 250 in four
colours to enable quick identification between
different loops.

Page 30
23SeptMXCat. qxd 11/10/02 11:43 pm Page 31

Tyco MKII Sounder Base Range Identification Card

A convenient pocket sized quick reference card Product Code


designed to aid the identification of the Tyco MKII 517.050.016
Sounder Base Range.
ID Cards
Note: Cards must be ordered in multiples of 100.
This concise card provides a simple, effective
reference key for rapid identification of sounder
base type during the initial visual system analysis
and needs assessment.

Page 31
23SeptMXCat. qxd 11/10/02 11:43 pm Page 32

MKII Sounder Base Applications Table

Page 32
23SeptMXCat. qxd 11/10/02 11:43 pm Page 33

800 Series Detector Locking Pins


Supplied in packs of 100 the detector locking Product Codes
pins allow 800 Series MX detectors to be locked UK EUROPE
to universal or functional bases to prevent them 517.050.005 571.071
from being accidentally or maliciously removed or Pack of 100 detector locking pins
swapped around.

801RIL - Remote Indication LED


All detector bases have the ability to drive a Product Code
remote LED in the event that the installed position 516.800.908
of the detector is not easily visible. The 801RIL is 801RIL remote indication LED
primarily designed for LPCB influenced markets
but is compatible with all 800 Series detectors.
Features
. UK Single gang mounting
. High intensity red LED

800HL - Indication Lamp


The 800HL remote indicator lamp provides a Product Codes
larger indicator for use in place of the RIL when UK EUROPE
longer distances are involved or in VdS 516.800.909 572.000
influenced markets. Typically used to indicate the 800HL indication lamp
source of an alarm in buildings with long
corridors eg. Hotels, hospitals, apartments.

800EM - Euro Mounting


The euro-mounting base provides a matching Product Codes
back box, which allows the standard MUB, and UK EUROPE
801IB to be ceiling mounted with conduit entries 516.800.921 572.031
for standard 18 and 21mm conduit. 800EM mounting base
Features
. 2 x 18mm conduit entries
. 2 x 21mm conduit entries
. Fits MUB & 801IB bases

DHM69 - Deck Head Mounting


Where 800 Series MX detectors are mounted in Product Code
humid and environmentally challenging situations 517.001.231
such as Marine or offshore installations the DHM69 deckhead mounting
DHM69 deck head mount provides a sealed
waterproof mounting which protects all electrical
connections.
Features
. 4 x 20mm gland entries
. Fits MUB and 801IB bases

W500 - Protective Detector Cage


The W500 is a strong white powder coated steel Technical Specification
cage designed to fit around 800 Series detectors Dimensions: 125 Dia x 85H mm
fitted with universal or functional bases. Weight: 161g
Features Product Code
. White powder coat finish 517.050.011
. Small mesh W500 detector cage

Page 33
23SeptMXCat. qxd 11/10/02 11:43 pm Page 34

Detector Housings
MP69 - Standard EN54 Duct Probe Unit
The MP69 is a tough fire resistant plastic Product Codes
enclosure incorporating an MUB universal UK EUROPE
detector base for use with 801PH optical 517.025.036 572.001
detectors. A clear polycarbonate cover allows the MP69 duct probe
detector and alarm LED to be easily viewed. An 517.001.035
internal baffle and precisely designed inlet and DP450 mm probe tube and exhaust
exhaust tubes provide maximum sensitivity at 517.001.036
very low air velocities. DP600 mm probe tube and exhaust
Features 517.001.037
. Probe tubes available from 450 to 1500mm DP750 mm probe tube and exhaust
(Minimum 200mm) 517.001.038
. Suitable for air speeds from 1.5 to 25m/s (4.9 DP900 mm probe tube and exhaust
to 82 feet/second) 517.001.039
. Optimised for fast response to smoke particles DP1200 mm probe tube and exhaust
. Easy access for detector servicing 517.001.040
DP1500 mm probe tube and exhaust

SMP69 - Stainless Steel Duct Probe Unit


The SMP69 is a stainless steel duct probe unit Product Codes
with the same features as the MP69 duct probe. UK EUROPE
Features 517.025.035 572.002
. Stainless steel 316 body and probe tubes SMP69 stainless steel duct probe
. Probe tubes available from 450 to 1500 mm 517.025.028
(Minimum 200mm) DPS450 mm probe tube and exhaust
. Suitable for air speeds from 1.5 to 25m/s (4.9 517.025.029
to 82 feet/second) DPS600 mm probe tube and exhaust
517.025.030
. Optimised for fast response to smoke particles
DPS750 mm probe tube and exhaust
. Easy access for detector servicing
517.025.031
DPS900 mm probe tube and exhaust
517.025.033
DPS1500 mm probe tube and exhaust

Detector Ancillary Technical Specifications


Model Height Width Length Weight Material Colour Power Temp. Humidity
mm mm mm gms oC %RH
MUB 10 108 NA 70 Bayblend White NA -25 to +90 NA
801IB 10 108 NA 70 Bayblend White 80A max -25 to +70 up to 95%RH
6B 21 152 NA 120 Bayblend White NA -25 to +90 up to 95%RH
801RB 36 108 NA 152 Bayblend White 20A -25 to +70 up to 95%RH
812RB 36 108 NA 152 Bayblend White 20A -25 to +70 up to 95%RH
801SB 36 108 NA 166 Bayblend White 0.5-1lpu# -25 to +70 up to 95%RH
800EM 85 125 125 TBA Bayblend White NA -25 to +90 NA
DHM69 40.5 145.5 145.5 184 Bayblend White NA -25 to +90 NA
800SA 22 109 NA 50 Bayblend White NA -25 to +70 NA
800HL 85 85 38 65 Polycarbonate White 200A Max -25 to +70 up to 95%RH
801RIL 22.5 85.5 85.5 50 Polycarbonate White 8.23mA Max -25 to +70 up to 95%RH
MP69 90 145 220 580 Polycarbonate White NA -20 to +70 up to 95%RH
SMP69 90 150 226 1200 SS316 & Polycarbonate S/Steel NA -20 to +70 up to 95%RH

# 1lpu (Loop Power Unit) = 15mA Loop Current or 25mA @ 24Vd.c. for Battery Calculations

Page 34
23SeptMXCat. qxd 11/10/02 11:44 pm Page 35

Aspirating Smoke Detectors VESDA - Vision Systems


VLC 800 MX VESDA Laser COMPACTTM
premium. This has been achieved through the Connects directly onto MX Loop
combination of approved LaserPLUS detection Provides Analogue Value at MX controller
technology, dual stage filtration technology and a
modified aspirator design incorporated in a Technical Specification
smaller enclosure with simplified display. The VLC Supply Voltage: 18 to 30Vd.c.
800 MX VESDA Laser COMPACT is available with Current Consumption: 225mA quiescent,
an inbuilt MX interface to enable it to 245mA in alarm
communicate directly with the MX loop.
Dimensions: 225H x 225W x 85Dmm
Weight: 1.9Kg
Features Operating Temp.: -10o C to+ 39oC
Reduced size Sampled Air: -20o C to +60 oC
Absolute smoke detection
Wide sensitivity range Product Codes
Single pipe inlet 516.018.012
Simple display c/w service LED VLC 800 MX Addressable Vesda Laser Compact
The VLC 800 MX VESDA Laser COMPACT TM
Dual stage dust filter (compatible with Version 2.1 and above)
detector has been specifically designed to
Air flow monitoring
provide all the benefits of aspirating smoke
Simple mounting design
detection, including very early warning, in single
AutoLearnTM
small environment areas and where space is a

MX Ancillaries
Callpoints & Pullstations - CP820 Indoor Callpoint
Technical Specification Product Codes
Meets BS5839 Pt.2 and pr EN54 Pt:11 514.800.503.T
EMC/RFI: Equal or exceeds EN50081- CP820 Indoor Callpoint (English Thorn
1 & EN50082-1 Branded)
Operating Temp.: -20 to +70oC 514.800.503.A
Relative Humidity: up to 95% RH non- CP820 Indoor Callpoint (English ADT Branded)
condensing 514.800.503.Y
Dimensions: 87H x 87W x 51(19mm flush CP820 Indoor Callpoint (English TYCO Branded)
mount)D mm 552.006
Weight: 200g CP820 Indoor Callpoint (International)
Quiescent Current: 0.25mA 514.800.511.T
Alarm Current: 2.5mA Thorn KAC Indoor Callpoint (Dutch)
Ident. Value: 129 552.004
The CP820 is an indoor MX addressable manual Zettler KAC indoor Callpoint (Dutch)
callpoint with programmable status LED. The 514.800.505.T
CP820 is designed for LPCB approvals and the CP820M Marine Indoor Call Point (Thorn)
CP820M for Marine approvals. The CP820
provides high speed communication to the MX
panel of a manual fire alarm.

Callpoints & Pullstations - CP830 Outdoor Callpoint


CP830M for Marine approvals. The CP830 Product Codes
provides high speed communication to the MX 514.800.504.T
panel of a manual fire alarm. CP830 Outdoor Callpoint (English Thorn
Technical Specification Branded)
Meets BS5839 Pt.2 and pr EN54 Pt:11 514.800.504.A
EMC/RFI: Equal or exceeds EN50081- CP830 Outdoor Callpoint (English ADT
1 & EN50082-1 Branded)
Operating Temp.: -20 to +70 oC 514.800.504.Y
Relative Humidity: up to 95% RH non- CP830 Outdoor Callpoint (English TYCO
condensing Branded)
Dimensions: 135H x 135W x 30D mm 552.007
Weight: 200g CP830 Outdoor Callpoint (International)
Quiescent Current: 0.25mA 552.005
Alarm Current: 2.5mA Zettler KAC Outdoor Callpoint (Dutch)
Ident. Value: 130 514.800.512.T
Thorn KAC Outdoor Callpoint (Dutch)
514.800.506.T
CP830M Marine Outdoor Callpoint (Thorn)
The CP830 is an outdoor MX addressable manual
callpoint with programmable status LED. The
CP830 is designed for LPCB approvals and the

Page 35
23SeptMXCat. qxd 11/10/02 11:44 pm Page 36

STOPPER
The callpoint STOPPER provides protection from
malicious or accidental activation of manual
callpoints. Available for flush or surface mounted
callpoints the STOPPER is also available with
optional high pitch sounder which is activated
when the lid is lifted.
An optional Break-Seal fitting kit allows Break-
Seals to be used to provide extra protection.
WARNING:-Break seals only to be fitted by
agreement with relevant fire authorities.
The STOPPER is suitable for all callpoints up to
100mm square, including CP820, CP920, CP200 Product Code
and other indoor KAC style callpoints. 515.001.033
IPO36 Break Seal Kit

STOPPER STOPPER II With Sounder Weatherproof


Product Code Ref Flush Surface
515.001.029 STI6530
515.001.030 STI6531
515.001.036 STI6535
515.001.034 STI1230
515.001.035 STI3150
515.001.031 STI6532
515.001.032 STI6533 4 4

STOPPER Dimensions

Millimetres
A 137
B 140
C 104
D 45
E 12.5
F 12.5
G 185
H 12.5

Flush Fit Surface Fit


(+30mm)
Stopper STI6530 STI6531
Stopper with Sounder STI6532 STI6533

STOPPER STOPPER II
Max. Callpoint Size 100 x 100mm 160 x 160 mm
STOPPER II Dimensions Max. Callpoint Depth 57.5 120
(+30mm Surface)

Millimetres
A 70
B 16
C 197
D 50
E 178
F 146
G 228
H 254
Stopper II Surface Fit - STI1230

Page 36
23SeptMXCat. qxd 11/10/02 11:44 pm Page 37

STOPPER II
STOPPERIIis constructed as the STOPPER from Product Code
tough injection moulded polycarbonate. 515.001.034
Physically larger than the STOPPER the STI1230 Surface fit STOPPERII
STOPPER II extends the number of products to
which these tough multi-purpose covers can
protect.
It consists of a strong tamper-proof clear
polycarbonate cover and frame that fits easily
over such products as break glass callpoints. The
STOPPER II can also be fitted with an integral
battery powered sounder which activates if the
cover is lifted.
The STOPPER II is suitable for callpoints up to
160mm square like the DIN820/830 and CP830.

Weather STOPPER & Weather STOPPER II


The Weather STOPPER and Weather STOPPERII
extends the life of weather exposed devices, such
as break glass callpoints, by offering protection
against harsh conditions and environments.
Experience has shown that this protective cover
can extend the life of products installed in saline
atmospheres, such as oil rigs and ship decks.
While offering environmental protection the
Weather STOPPER and Weather STOPPER IIare
constructed from tough durable polycarbonate
which will also guard against tampering,
vandalism or accidental operation of devices such
as emergency switches.
Product Codes
515.001.036
STI6535 Surface fit Weather STOPPER
515.001.035
STI3150 Surface fit Weather STOPPER II

Callpoint Ancillaries

Product Code Product Codes Product Code


515.001.028 515.001.021 90-107
Callpoint hinged cover for use on CP820 models Standard Red surface mounting back box for Red M141 spacer for red CP820 KAC callpoints
CP820 callpoints

Spare Test Keys


Product Codes
90-106
Test keys for all KAC callpoints

Product Codes Product Code


515.001.025 515.001.026
CP820/830 Glasses, clear English text on white Black callpoint bezel for CP820
background. No logo (pack 5). Fitted as standard
to English CP820/830 Callpoints

Page 37
23SeptMXCat. qxd 11/10/02 11:44 pm Page 38

MX Addressable Input/Output Modules


Tyco MX TECHNOLOGY provides a large range of addressable ancillary devices which can be programmed and tested with the MX SERVICE tool. The first
group of modules to be made available is shown in detail in this section. Other modules including intrinsically safe devices, multiple input/output devices,
emergency telephone and the MX addressable voice evacuation amplifiers and ancillaries will follow later.

APM800 Addressable Power Supply Monitor


The APM800 is an MX addressable power supply Dimensions: 24H x 127W x 57D mm
monitoring module which is usually used with the Weight: 0.794Kg
PSM800 power supply module to make an Quiescent Current: 0.1mA (APM800 - 1 from
addressable power supply. The APM800 is loop)
designed to fix to studs on the top of the 0.3mA (from PSU)
PSM800. The APM800 monitors the PSM800 for Alarm Current: 0.1mA (APM800 - 1 from
mains failure, earth fault, battery charger fault and loop)
battery fault. It can reset the PSM800 resettable 0.3mA (from PSU)
24Vd.c. output and initiate a battery test which Ident. Value: 162
then reports battery voltage and current to the Product Codes
controller. 557.202.027
Technical Specification APM800 addressable power supply monitor (UK)
EMC/RFI: Equal or exceeds EN50081- 572.018
1 & EN50130-4 APM800 addressable power supply monitor
Operating Temp.: -20 oC to +70 oC (EUROPE)
Relative Humidity: up to 95% RH non-
condensing
MIM800 Mini-Input Module (E)
The MIM800 is a small MX addressable module Dimensions: 13H x 48W x 57D mm
designed for monitoring a single input circuit. The Weight: 100g
MIM800 can monitor normally open or normally Quiescent Current: 0.25mA
closed inputs and provides open and short circuit Alarm Current: 0.25mA (without LED)
monitoring of the line. The MIM800 is designed 2.5mA (with LED)
for fitting in small devices such as flow switches, EOL resistor: 200 Ohm
special detection devices and explosion proof Monitor Resistor: 100 Ohm
callpoints. A variant of the MIM800 is used in all Ident. Value: 128
callpoints and pullstations. Product Codes
Technical Specification 555.800.001
EMC/RFI: Equal or exceeds EN50081- MIM800 mini-input module (UK)
1 & EN50130-4 572.016
Operating Temp.: -20 oC to +70 oC MIM800 (E) mini-input module (EUROPE)
Relative Humidity: up to 95% RH non-
condensing

CIM800 Contact Input Module (EK)


The CIM800 is a flexible addressable input- condensing
monitoring device that fits in the standard Dimensions: 14H x 148W x 87D mm
ancillary housings. The CIM800 provides a single Weight: 100g
input to current MX panels though this can be Quiescent Current: 300A
implemented as two separately wired spurs (Style Alarm Current: 3mA
B) or as a loop (Style A). Both spur and loop EOL & monitor resistor: 10k Ohms
input wiring can be configured to monitor Ident. Value: 145
normally open or normally closed inputs. In Product Codes
addition both can be configured to initiate an 555.800.002
alarm or short circuit fault message in the event of CIM800 contact input monitor (UK)
a short circuit on normally open monitoring 572.017
circuits. CIM800 (EK) contact input monitor (EUROPE)
Technical Specification 555.800.032
EMC/RFI: Equal or exceeds EN50081- CIM 800 Module c/w Front Cover (UK)
1 & EN50130-4 572.020
Operating Temp.: -20 oC to +70 oC CIM 800 Module in isolated D800 housing
Relative Humidity: up to 95% RH non- (EUROPE)

DIM800 Detector Input Module (ADK)


an external 24V d.c. supply and is reset by the Technical Specification
MX addressable panel. The DIM800 monitors the EMC/RFI: Equal or exceeds EN50081-
external 24V d.c. and provides a fault signal if it is 1 & EN50130-4
lost. The input detection circuit can be wired as Operating Temp.: -20o C to +70o C
Relative Humidity: up to 95% RH non-
one or two spur circuits (Class B), one loop
condensing
configured circuit (Class A) or one 4 wire Dimensions: 14H x 148W x 87D mm
detection circuit. Weight: 100g
The DIM800 is designed to be compatible with Quiescent Current: 0.1mA (from loop)
most conventional detection products. 7.5mA (from ext. supply)
Compatibility has been tested to date on the Alarm Current: 0.1mA (from loop)
following products: 50mA (from ext. supply)
Compatible Thorn detectors: Ident. Value: 145
Product Codes
M300 Series , M601 Series , S100 Series, H
555.800.012
Series, S231F, S231F+, CP200 DIM800 detector input monitor (UK)
Compatible Zettler detectors: 562.011
M613 Series. DIM800 (ADK) detector input monitor (EUROPE)
555.800.042
DIM 800 Module c/w front cover (UK)
The DIM800 is designed to power and monitor a
562.012
circuit of low voltage conventional detectors and DIM800 Module in isolated D800 housing
callpoints. The detection circuit is powered from (EUROPE)
Page 38
23SeptMXCat. qxd 11/10/02 11:44 pm Page 39

RIM800 Relay Interface Module (AN)


The RIM800 provides a single programmable Dimensions: 14H x 148W x 87D mm
relay output from the MX DIGITAL addressable Weight: 100g
loop which can be programmed for a variety of Quiescent Current: 200A
applications including signalling fire conditions to Alarm Current: 3mA
plant, machinery, fire doors, dampers & security Relay contacts: 2A @ 24V d.c.
systems. The RIM800 relay coil is monitored. The Ident. Value: 161
RIM800 relay contact is rated for 2A @ 24V d.c. Product Codes
but can be used to switch mains voltage when 568.800.003
used with the HVR800. This unit has two opto- RIM800 relay interface module (UK)
isolated terminals specifically for driving the 572.007
HVR800. RIM800 (AN) relay interface module (EUROPE)
Technical Specification 568.800.033
EMC/RFI: Equal or exceeds EN50081- RIM 800 Module C/W Front Cover (UK)
1 & EN50130-4 572.021
Operating Temp.: -20o C to +70o C RIM800 Module in isolated D800 housing
Relative Humidity: up to 95% RH non- (EUROPE)
condensing

HVR800 High Voltage Relay Module (NSE)


The HVR800 module is a non-addressable device Dimensions: 26.5H x 42W x 74D mm
which allows a low current mains rated relay to Relay Contacts: Up to 10A @ 250Va.c.
switch up to 10A. Alternatively a low voltage drive Product Codes
signal such as that provided by the RIM800 or 80 568.800.004
way mimic can be used to switch the integral HVR800 OEM high voltage relay (UK)
mains relay via the opto-isolated input. 568.800.034
Technical Specification HVR800 in isolated D 800 housing (UK)
EMC/RFI: Equal or exceeds EN50081- 572.008
1 & EN50130-4 HVR800 (NSE) high voltage relay (EUROPE)
Operating Temp.: -20oC to +70 oC 572.022
HVR800 in isolated D800 housing (EUROPE)
Relative Humidity: up to 95% RH non-
condensing

SNM800 Sounder Notification Module (A)


The SNM800 is a remote addressable sounder condensing
circuit output device capable of switching Dimensions: 14H x 148W x 87D mm
sounder and speaker circuits up to 2A @ 24V d.c. Weight: 100g
or provide a monitored output facility for other Quiescent Current: 0.5mA
applications. These can be used in addition to the Alarm Current: 3mA
two circuits provided as standard on most MX Output rating: 2A @ 24V d.c.
detection panels. EOL resistor: 27k 1/2W
The SNM800 can support sounder circuits wired Ident. Value: 177
as a spur (Class B Style Y) or in a loop Product Codes
configuration (Class A Style Z). 577.800.005
The SNM800 can be configured with a RIM800 to SNM800 sounder notification module (UK)
provide a secure monitored extinguishing release 572.009
solenoid control. SNM800 (A) sounder notification module
Technical Specification (EUROPE)
EMC/RFI: Equal or exceeds EN50081- 577.800.035
1 & EN50130-4 SNM800 Module c/w Front cover (UK)
Operating Temp.: -20oC to +70 o C 572.023
Relative Humidity: up to 95% RH non- SNM800 Module isolated D800 housing (EUROPE)

LPS800 Loop Powered Sounder Module


output circuit with up to 75mA of power sourced Ident. Value: 178
from the MX panel. Product Codes
Technical Specification 577.800.011
EMC/RFI: Equal or exceeds EN50081- LPS800 Loop Powered Sounder module (UK)
1 & EN50130-4 572.014
Operating Temp.: -20oC to +70 oC LPS800 Loop Powered Sounder module
Relative Humidity: up to 95% RH non- (EUROPE)
condensing 577.800.041
Dimensions: 14H x 148W x 87D mm LPS800 Module c/w front cover (UK)
Weight: 100g 572.027
Quiescent Current: 0.93mA LPS800 Module in isolated D800 housing
Alarm Current: Up to 75mA continuous (EUROPE)
Output rating: 120mA @ 24V d.c. max NOTE: Each MX Digital Loop can provide up to 495mA for
The LPS800 provides a single monitored sounder LPS800, 801SB AND 802SB.

SB520 Sounder Booster Module


SNM800 to drive circuits with higher currents per terminal
whilst maintaining the reverse polarity integrity Ident. Value: Non addressable
line monitoring. Product Codes
Technical Specification 577.001.023
EMC/RFI: Equal or exceeds EN50081- SB520 Sounder Booster Module (UK)
1 & EN50130-4 572.012
Operating Temp.: -20o C to +70o C SB520 Sounder Booster Module (EUROPE)
Relative Humidity: up to 95% RH non- 577.001.033
condensing SB520 Module c/w Front Cover (UK)
Dimensions: 14H x 148W x 87D mm 572.024
Weight: 100g SB520 Module in isolated D800 housing
The SB520 sounder booster module enables the Output rating: 15A @ 24V d.c./10A Max. (EUROPE)
Page 39
23SeptMXCat. qxd 11/10/02 11:44 pm Page 40

LI800 Line Isolator Module


section whilst allowing the rest of the addressable Product Codes
loop to function normally. The LI800 Ancillary 545.800.001
Line Isolator Module ensures that on a looped LI800 Ancillary Line Isolator Module (UK)
addressable system a short circuit fault cannot 572.019
disable more detection devices than would be LI800 Ancillary Line Isolator Module (EUROPE)
lost on a conventional non-addressable system in 545.800.031
accordance with BS5839 Part 1. LI800 Ancillary Line Isolator Module c/w front
cover (UK)
Technical Specification 572.026
EMC/RFI: Equal or exceeds EN50081-1 & LI800 Ancillary Line Isolator Module in Isolated
EN50130-4 D800 Housing (EUROPE)
Operating Temperature: -25C to +70C
Relative Humidity: Up to 95% RH non-condensing
Dimensions: 14H x 148W x 87D mm
Weight: 100g
Battery Requirements:
Standby 160A Max
Tripped One short circuit less than 2.5mA,
The LI800 Ancillary Line Isolator Module is Two short circuits less than 3.6mA.
designed to be used on all MX addressable
loops. It monitors the line condition and upon
detection of a short circuit it isolates the affected

TM520 Timer Module


The TM520 provides an output that can be The TM520 requires a separate 24V DC supply to
activated based on a delay time. If either the key- operate. The module is not addressable and will
switch on the module is activated, or a predefined therefore not take an address on the loop.
event within the control panel occurs then a Technical Specification
timed delay (set between 10 minutes and 2 hours Powered: 24Vd.c.
10 minutes) is started. When the delay reaches Temperature Range: -10o C to +70o C
zero the TM520 output is activated. The unit Operating Humidity: >95% RH
sounds an internal buzzer and shows a red LED Dimensions: 87H x148W x 14D mm
when the output is active, and shows a yellow Product Codes
LED when the timer is counting down. To provide 557.180.423
a warning that the delay is nearly over, the red TM520 timer module - non addressable
LED and the buzzer will pulse 5 minutes before
the end of the delay .

LAV800 VdS Extinguishing Interface


The LAV800 provides an MX addressable Weight: 100g
standard VdS extinguishing interface in a Quiescent Current: 300A
standard MX ancillary size package. Alarm Current: 3mA
Technical Specification Ident. Value: 180
EMC/RFI: Equal or exceeds EN50081- Product Codes
1 & EN50130-4 572.015
Operating Temp.: -20o C to +70oC LAV800 VdS extinguishing interface (EUROPE)
Relative Humidity: up to 95% RH non- 572.025
condensing LAV800 Module in isolated D800 housing
Dimensions: 14H x 148W x 87D mm (EUROPE)

SIO800 Single Input/Output Module


Controller. The LED may be turned ON or OFF by Product Codes
the controller during a relay activated condition. 555.800.063
SIO800 Single Input/Output Module (compatible
with Version 2.1 and above)
Technical Specification 555.800.064
EMC/RFI: SIO800 Single Input/Output Module c/w Front
Product Family standard EN50130-4 in respect of Cover (compatible with Version 2.1 and above)
Conducted Disturbances, Radiated Immunity,
Electrostatic Discharge, Fast Transients and Slow
High Energy.
EN50081-1 for Emissions.
Operating Temperature: -25C to + 70 C
Relative Humidity: Up to 95% RH
non-condensing
Dimensions: 14H x 148W x 87D mm
The SIO800 single Input/Output Module is Weight: 105g
designed to provide a monitored input and a volt Quiescent Current: 0.3mA
free relay changeover output. It consists of an Alarm Current: 3mA
input for monitoring the status of a normally open EOL Resister: 3k3
contact and output of changeover relay contacts Ident Value: 148
The relay is controlled by a command sent from
the Minerva MX Fire Controller via the
addressable loop.

The state of the relay (activated,deactivated or


stuck) is reported to the Minerva MX Fire

Page 40
23SeptMXCat. qxd 11/10/02 11:44 pm Page 41

DIO 800 Dual Input/Output Module


The DIO800 provides two monitored detector Technical Specification
circuits and two 24V outputs on a single board. Operating Temperature: -20 C to + 70C
The unit is supplied as a chassis mount for Relative Humidity: Up to 95% RH
incorporation into any suitable enclosure such as Non-Condensing
the ANC-3 housing or complete with its own Dimensions:
enclosure. The unit requires a 24 V power supply 74mm H x 101mm W x 25.6mm D (with
and each of the two class B detection circuits can housing)
drive up to 20 of the 600 series conventional Weight: 136g
detectors.Each input has an associated 24V Quiescent Current: External 8.0mA, Loop 0.28mA
output with the same address. Only two Alarm Current: External 80mA, Loop 0.28mA
addresses are required for the unit programmed EOL Resistor: 10K ohm
via the 801AP address-programming tool . Outputs: 2 x 200A @ 24Vdc
MXConsys is used to assign a functional group to Ident Value: 193
an input point, commands are then sent to this
group to control the appropriate output. Two Product Codes
LEDs indicate the status of the two inputs. 555.800.062
DIO 800 Dual Input/Output Module c/w Enclosure
(compatible with Version 2.1 and above).
555.800.022
DIO 800 Dual Input/Output Module (compatible
with Version 2.1 and above)

Page 41
23SeptMXCat. qxd 11/10/02 11:44 pm Page 42

MX Ancillary Housings
MX Ancillary Housings
A variety of ancillary housings are available to fit ancillary housings. VdS certification is with the cover.
the 800 Series MX ancillaries. Zettler ancillary box and ancillary housings. The All options allow the ancillary to be programmed
The standard sized modules are mechanically M520 double gang cover provides external and tested when the cover is removed.
compatible with all options. LPCB approvals are access for the MX SERVICE TOOL to plug into
with the M800 double gang cover plate or the ancillary module which is mounted in the

517.035.007 557.201.401 572.004


M520 Ancillary cover for use with 800 modules D800 IP65 ancillary housing

517.035.011 517.035.010 517.035.014


K2214 ALM Metal surface mount MK backbox for use MK K2142 White plastic surface mount MK backbox 8621C Steel flush mount MK backbox for use with
with M520 or 800 Series addressable ancillaries for use with M520 or 800 Series addressable M520 or 800 Series addressable ancillaries using
using 517.035.007 cover. Includes 7 x 20mm ancillaries using 517.035.007 cover. 517.035.007 cover with knockouts.
knockouts.
Product Code MKRef Mounting Dimensions Knockouts Earth Screw Material
517.035.011 K2214 Surface 146x86x40mm 1x20mm rear/7x20mm sides Yes Steel
517.035.010 K2142 Surface 146x86x34mm One rear (25x35mm) N/A Plastic
517.035.014 MK862/KFlush 132x72x26mm 4x20mm rear/12x20mm sides Yes Steel
517.035.015 QFB/2 Flush/ 146x85x38mm 2 top & bottom N/A Plastic
Dry Lining
517.035.015
QFB/2 Dry lining flush mount (for plasterboard
etc) MK backbox for use with M520 or 800 Series
addressable ancillaries using 517.035.007 cover.

ANC-3 & ANC-8 Ancillary Housing


Most addressable modules can be fitted into a double gang MK style backbox using the M520 ancillary cover. Where several devices are mounted in one
place the ANC3 houses 3 x modules and the ANC8 houses 8 modules, expandable to 16 using the STK8 stacking kit.

ANC-3 Ancillary Housing


Product Codes 557.180.097.Y
557.180.097.A ANC-3 MINERVA ancillary housing - for use with
ANC-3 MINERVA ancillary housing - for use with M800 ancillary modules (can accommodate up to
M800 ancillary modules (can accommodate up to 3 M800 modules)
3 M800 modules) ADT Branded
557.180.097.T
ANC-3 MINERVA ancillary housing - for use with
M800 ancillary modules (can accommodate up to
3 M800 modules) Thorn Branded

Page 42
23SeptMXCat. qxd 11/10/02 11:44 pm Page 43

ANC-8 Ancillary Housing


Product Codes 557.180.096.Y 572.034
UK EUROPE ANC-8 MINERVA ancillary housing - for use with
557.180.096.A X800 ancillary modules (can accommodate up to
ANC-8 MINERVA ancillary housing - for use with 16 X800 modules with stacking kit)
X800 ancillary modules (can accommodate up to 557.180.095 572.036
16 X800 modules with stacking kit) ADT Branded STK-8 MINERVA ancillary stacking kit for use with
557.180.096.T ANC-8 ancillary housing
ANC-8 MINERVA ancillary housing - for use with
X800 ancillary modules (can accommodate up to 16
X800 modules with stacking kit) Thorn Branded

Callpoint & Ancillary Address Labels


Product Codes 599.047.024
Zone Labels Zone labels - Zones 221 - 240
599.047.011 Address Labels
Zone labels - Zones 1 - 16 599.047.030
599.047.012 Address Labels 1 - 250 Loop A - White
Zone labels - Zones 17 - 32 599.047.031
599.047.013 Address Labels 1 - 250 Loop B - Yellow
Zone labels - Zones 33 - 48 599.047.032
599.047.014 Address Labels 1 - 250 Loop C - Purple
Zone labels - Zones 49 - 64 599.047.033
599.047.015 Address Labels 1 - 250 Loop D - Green
Zone labels - Zones 65 - 80
599.047.016
Zone labels - Zones 81 - 100
599.047.018
Zone labels - Zones 101 - 120
Detectors have a special address flag for carrying the 599.047.019
address labels - details in the detector section. For Zone labels - Zones 121 - 140
other devices or on detectors where zone information 599.047.020
is also required a series of address labels are Zone labels - Zones 141 - 160
available. 599.047.021
Numbered 1 to 250 the address labels are available Zone labels - Zones 161 - 180
in 4 different colours to distinguish between different 599.047.022
loops. In addition small zone labels can be fixed to Zone labels - Zones 181 - 200
the address labels. 599.047.023
Zone labels - Zones 201 - 220

Page 43
23SeptMXCat. qxd 11/10/02 11:44 pm Page 44

Programming and Service Tools


MX SERVICE Tool
Suitable for desktop or single handed operation Product Codes
the MX SERVICE tool is battery operated using 516.800.918
standard rechargeable batteries. An accessory 801AP MX SERVICE tool English
pack provides alternative straps, and cigarette 516.800.922
lighter adaptor. Spare ancillary programming lead - English
572.006
Software Features include: 801AP MX SERVICE tool German
. Read/write the detector/ancillary address 572.030
. Display date of manufacture and Spare ancillary programming lead- German
commissioning 516.800.924
. Display serial number Pack of Spare Pins (Pk 10)
. Display temperature/ CO levels / smoke 516.800.926
obscuration MX Service Tool PMS Dongle Parallel
. Programming of the LED 516.800.928
. Testing the detector remote LED and control AVRISP-02-MX PMS Programming Lead
The TYCO MX SERVICE tool is a powerful and outputs
flexible tool for assistance in the installation, . Perform the detector self verification test The MXService tool has a finite life time after
commissioning, diagnostics and service of Tyco function which the software must be recharged by an MX
MX detection systems. The MX SERVICE tool . Displaying detector dirtiness level authorised administrator.
allows all MX addressable devices to be . Controlling ancillary outputs
interrogated, tested and programmed. . Reading ancillary statuses
. Power management options

MX Service Accessory Kit


A carry case which contains the following items:- Product Codes
Car Lighter Adapter 516.800.923
Shoulder Strap MX SERVICE accessory kit - UK
572.032
This provides space for the following:- MX SERVICE accessory kit - German
801AP MX Service Tool
Ancillary Programming Lead
Mains Charger

MX CONSYS
MX CONSYS is a powerful Windows 95 and 98 It also supports automatic data transfer to MX
compatible programming tool which provides full GRAPH, graphical mimic and alarm management
system programming functions and project systems. MX CONSYS is available under
configuration and issue control. MX CONSYS is document control from authorised personnel in
used on MINERVA MX, T2000, ZETTLER EXPERT the Tyco businesses.
and AUTOCALL MX panels. Product Codes
Features UK EUROPE
. Windows based 557.203.001
. Programs the system across multiple sub- MXCONSYS Dongle and license (parallel port)
panels 557.202.118 542.011
. Downloads to the system from one point MXCONSYS Download lead
. Supports remote dial in capability 557.203.003
. Provides software download as well as MXCONSYS Dongle and license (USB)
configuration download
. Dongle protected
. Provides full project configuration printouts
MX REMOTE
MX REMOTE is a Windows based software tool Product Codes
for remote service and support and MX detection 557.203.002
panels. MX REMOTE provides a full function fire MXRemote dongle and license (parallel)
panel repeater running on a PC either locally or 557.203.004
over dial up telephone lines. Providing the MXRemote Dongle and license (USB)
operator has the correct passwords MX REMOTE 557.202.036
allows all operator, manager, service and engineer MXRemote modem (BABT)
functions available at the panel to be provided at 542.036
the PC. This allows the customer or the Tyco 24Vd.c. MX Remote Modem (EU)
service organisation to provide remote
assistance, service and limited configuration
assistance to the installation.
MX REMOTE is available as a stand-alone
software application for Tyco service operations.
Alternatively TEPG are able to provide
consultancy and assistance in implementing MX
REMOTE as an integrated part of a central station
and service centre system.

Page 44
23SeptMXCat. qxd 11/10/02 11:44 pm Page 45

MX DEMO CASE
An MX Panel, 801CH Detector, 801PH Detector,
LEDs and Switches mounted in a carry case and
pre-configured with demo software.

Product Code
557.200.901

SOLO Detector Service Equipment

Product Codes
517.001.224
SOLO704 Adaptor tube B - Adapts SOLO100/101 517.001.233
pole sets for TYCO detector changers and testers
CO Detector field test kit with 24 brickets for use with
517.001.230 SOLO330
517.001.255 517.001.234
SOLO100 Telescopic extension pole 1.26M to
SOLO330 Aerosol dispenser for use with all detector CO Fire Detector field test kit spare bricks (Pack of
4.5M long ranges. Connects directly to SOLO100/101 poles 24)
517.001.226
SOLO101 Extension tube 1.3M long for use with
517.001.230 telescopic extension pole
517.001.228
SOLO600 Carry all bag for detector test kit
517.001.242
SOLO720 Spare battery baton for use with SOL O
450/460 tester
517.001.243
SOLO724 Spare mains/car battery charger for
SOLO720 battery baton
517.001.264 517.001.254
SOLO461 Cordless heat detector tester kit including: 571.001.256
SOLO 610 Protective Carry/Storage Bag for Solo
SOLO460 tester, SOLO720 battery batons and Suretest Solo aerosol tester can. For use with
Detector Test Kit SOLO724 charger. (Connects directly to SOLO330 dispenser. Non-flammable, ozone and
SOLO100/101 poles). environment friendly. Approx 200 tests per can

800RT Detector Removal Tool


The 800RT detector removal tool fits the SOLO Product Codes
range of telescopic poles and allows the 800 516.800.917
Series detectors to be remotely fitted, removed 800RT removal tool
and turned to the park position. The tool also 572.005
enables detector dust covers to be easily 800RT removal tool with ZETTLER pole adaptor
removed.
The 800RT is also compatible for use with M600
and M900 Series Low Profile detectors.

Sales Tools
Videos & Brochures
Product Codes PSV011
PSV001 Tyco MX Technology - Dutch PAL format
Carbon Monoxide Low Profile detector - English PSV012
PALformat Tyco MX Technology - Spanish PAL format
PSV008 PSV013
Tyco MX Technology - English PALformat Tyco MX Technology - Spanish NTSC format
PSV009 PBMX01
Tyco MX Technology - English NTSCformat Tyco MX Technology Brochure - English version
PSV010 PBMX01E
Tyco MX Technology - German PAL format Tyco MX Technology Brochure - Spanish version

Page 45
23SeptMXCat. qxd 11/10/02 11:44 pm Page 46

APPROVALS LISTING OF COMPANY EQUIPMENT


Thorn Security Limited is registered by British Standards Institution to BS5750 : Part 1 KRS Korean Register of Shipping.
Note: That while every effort is made to keep this document updated, some approvals LPCB Loss Prevention Certification Board.
will be renewed and new approvals will be acquired between updates. Any queries, LRS Lloyds Register of Shipping.
reference approvals, should be made to the Approvals Engineer [TYCO SAFETY
MIE Spanish Ministry of Industry and Energy
PRODUCTS} Sunbury-on-Thames.
MOI Italian Ministry of the Interior.
The approvals obtained for company equipment are listed in Table 1. The approval
bodies are identified by the following abbreviations:- MSA Marine Certification Association
AMSA Australian Maritime Safety Authority. NACOS S National Approval Council for Security Systems.
ABS American Bureau of Shipping. NC Not Coded.
BT British Telecom. NKK Japanese Register of Shipping.[Nippon Kaiji Kyokai].
BASEEF A British Approval Service for Electrical Equipment in Flammable NMA(S) National Maritime Administration [Sweden, Sjfartsverket].
Atmospheres. NMD Norwegian Maritime Directorate [Sjfartdirektortet].
BR Brunamalastofnun Rikisins [Iceland Govt. Approval]. NSI Nederlands Shipping Inspectorate.
BSI British Standards Institute. NPTT Dutch Post Office.
BV Bureau Veritas [France]. NRC Nuclear Regulatory Commission [USA].
CCG Canadian Coastguard. NRPB National Radiological Protection Board [UK].
CCR China Corporation Register of Shipping. NSTC China - National Supervisory Test Centre China.
CCS (ZC) China Classification Society. PRS Polish Register of Shipping.
CIRL Construction Industry Research Laboratory [Australia]. PSB Productivity Standards Board of Singapores Product Listing
CSA Canadian Standards Association. Scheme (PLS)
DDRK DDR Schiffsrevision und Klassifikation [Germany]. PTB Physikalisch Technisches Bundesanstalt [Germany].
DMA Danish Maritime Authority [Sfartsstyrelsen]. RA Radiocommunications Authority [DTI]
DOT Department of Transport [UK] - not used. Now Marine RINA Registro Italiano Navale [Italy].
Certification Association [MSA]. RNR Rumanian Register of Shipping.
DNV Det Norske Veritas. RRS Maritime Register of Shipping [Russia].
DTI Department of Trade and Industry. SAA Standards Association of Australia.
FM Factory Mutual [USA]. SSL Scientific Services Laboratory of Australia
GL Germanischer Lloyd. UL Underwriters Laboratories of the United States.
HRS Hellenic Register of Shipping ULC Underwriters Laboratories of Canada
IPT T An Roinn agus Telegrafa [Irish Posts, Telephones and USCG United States Coastguard.
Telegraphs]. VdS Verband der Sachversicherer e.V. [Association of Property
IR India Radiology. Insurers] (Germany).
KM & P A Korean Marine and Port Authority.

TABLE 1: APPROVALS LISTING OF COMPANY EQUIPMENT


Type Description Authority
ANN 840 LED ANNUNCIATOR LPCB
Type Description Authority
ANN 880 LED ANNUNCIATOR LPCB
T2000R MARINE REPEATER PANEL ABS, BV, KRS, UL, RINA
CIM800 CONTACT INPUT MODULE LPCB (PENDING)
(PENDING), LRS (PENDING), GL
(ABS/BV/DNV/GL/KRS/LRS/NKK
(PENDING) NKK (PENDING),
PENDING) USCG (PENDING)
COM820 STATUS COMMAND MODULE LPCB XLM800 LOOP EXPANSION MODULE LPCB
CP820 INDOOR CALLPOINT LPCB (PENDING) ZX1 SINGLE LOOP PANEL VdS
CP820M INDOOR CALLPOINT (ABS/BV/DNV/GL/KRS/LRS/NKK
ZX4 TWO TO FOUR LOOP PANEL VdS
PENDING)
ZXF REPEATER PANEL VdS
CP830 OUTDOOR CALLPOINT LPCB (PENDING)
ZXS 16 ZONE TWO LOOP SOLO VdS (PENDING)
CP830M OUTDOOR CALLPOINT (ABS/BV/DNV/GL/KRS/LRS/NKK PANEL
PENDING)
ZXS 16 ZONE SOLO REPEATER VdS (PENDING)
CPU800 CENTRAL PROCESSOR UNIT LPCB
PANEL
DIM800 DETECTOR INPUT MODULE LPCB(PENDING), VdS (PENDING) 801B STANDARD BASE LPCB
FB800 FUSE BOARD LPCB 801CH CARBON MONOXIDE/ LPCB, VdS
FIM800 FIELD INTERFACE MODULE LPCB HEAT DETECTOR
HVR800 HIGH VOLTAGE RELAY MODULE LPCB (PENDING) 811CH CARBON MONOXIDE/ ABS,DNV, KRS, LRS, MCA, RINA/
HEAT DETECTOR MOI (PENDING), NKK (PENDING)
IOB800 INPUT/OUTPUT EXPANSION BOARD LPCB
814CH CARBON MONOXIDE/ SSL
LAV800 VdS EXTINGUISHING INTERFACE LPCB (PENDING) VdS (PENDING) HEAT DETECTOR
LI800 LINE ISOLATOR MODULE VdS (PENDING) 801H HEAT DETECTOR LPCB,VdS
MIM800 MINI INPUT MODULE LPCB (PENDING) 811H HEAT DETECTOR ABS,DNV,KRS,LRS,MCA,
(ABS/BV/DNV/GL/KRS/LRS/NKK
RINA/MOI (PENDING),
PENDING)
MPM800 MULTI PURPOSE INTERFACE LPCB NKK (PENDING), USCG
MODULE (PENDING)
MX1000 SINGLE LOOP PANEL BV, LPCB, UL 812H HEAT DETECTOR UL
MX4000 TWO TO FOUR LOOP PANEL BV, LPCB, UL 814H HEAT DETECTOR SSL
MXR REPEATER PANEL LPCB 801I IONISATION DETECTOR LPCB, VdS
MXS 8/16 ZONE SINGLE LOOP SOLO PANEL LPCB (PENDING) 812I IONISATION DETECTOR UL
MXS 8/16 ZONE SOLO REPEATER PANEL LPCB (PENDING) 814I IONISATION DETECTOR SSL
OCM800 OPERATOR CONTROL MODULE LPCB 801IB ISOLATORBASE LPCB, VdS
ODM800 OPERATOR DISPLAY MODULE LPCB 801PH OPTICAL/HEAT DETECTOR LPCB,VdS
811PH OPTICAL/HEAT DETECTOR ABS,DNV,KRS,LRS, MCA, UL
PSB800 POWER SUPPLY BOOSTER MODULE LPCB
RINA/MOI (PENDING), NKK
PSM800 POWER SUPPLY MODULE LPCB
(PENDING), USCG (PENDING)
RIM800 RELAY INTERFACE MODULE LPCB (PENDING)
812PH OPTICAL/HEAT DETECTOR UL
SIO800 SINGLE INPUT/OUTPUT MODULE LPCB (PENDING)
814PH OPTICAL/HEAT DETECTOR SSL
SNM800 SOUNDER NOTIFICATION MODULE LPCB (PENDING)
(ABS/BV/DNV/GL/KRS/LRS/NKK
PENDING) 801RB RELAY BASE LPCB,VdS,
(ABS/BV/DNV/GL/KRS/LRS/NKK
T2000 TWO TO FOUR LOOP MARINE PANEL ABS, BV, KRS, UL, RINA
PENDING)
(PENDING), LRS (PENDING), GL
(PENDING), NKK (PENDING), 812RB RELAY BASE UL
USCG (PENDING) 801SB SOUNDER BASE LPCB
802SB SOUNDER BASE LPCB (PENDING)
812SB SOUNDER BASE UL

Page 46
23SeptMXCat. qxd 11/10/02 11:44 pm Page 47

Standard AutoCAD Symbols


Tyco Electronic Product Group now has an IntraNet Products and also Diagrams for many Tyco If you require any further information on this or other
site devoted to users of AutoCAD Design Packages Electronic Product Group products supplied from the aspects of CAD development please contact Lisa
for electronic and electrical systems. UK, this will be expanded to include all Tyco Thomson on Tel: +44 (0) 1932 743321, Fax: +44 (0)
The site has been set up with a view to utilising a Electronic Product Group products. 1932 743330 or e-mail: lthomson@tycoint.com or
common approach to AutoCAD output for drawing Please encourage your CAD operators to visit this alternatively visit our website at www.tycofire.com
offices using Tyco Electronic Product Group products website. Even if you're business doesn't use all these
and systems. products many of the symbols, schematics and draw-
Initially this site includes Standard Symbols for Tyco ings may be adapted quickly and easily for other
MX Technology & MX-Graph, Fire and Access products.

Symbol Name Symbol Name Symbol Name


APM800.dwg CIM800.dwg DIM800.dwg
APM800 Addressable Power CIM800 Contact Input Module DIM800 Detector Input
Supply Monitor Module

Symbol Name Symbol Name Symbol Name


FCOTGX.dwg FCPSTGX.dwg FHTGX.dwg
CODetector Weatherproof/I.S. Callpoint, 801H Detector
Callpoint (Addressable and
conventional)

Symbol Name Symbol Name Symbol Name


FITGX.dwg FPHDPTGX.dwg FPHTGX..dwg
801I Detector 801PHDuct Probe Detector 801PHDetector

Symbol Name Symbol Name Symbol Name


HVR800.dwg LAV800.dwg LPS800.dwg
HVR800 High Voltage Relay LAV800 VdS Extinguishing LPS800 Loop Powered
Module Module Sounder Module

Symbol Name Symbol Name Symbol Name


MIM800.dwg MXPANEL.dwg RIM800.dwg
MIM800 Mini Input Module MX Panels (all types) RIM800 Relay Interface
Module

Symbol Name Symbol Name Symbol Name


SNM800.dwg TM520.dwg AWORKST ATION.dwg
SNM SNM800 Sounder Notification TM520 Timer Module (non PC
Module addressable)

Page 47
MXcatCOVandback.QXD 11/10/02 11:51 pm Page 2

Whos Where?
Product Management Sales Order Processing (UK) Distribution Centre (UK)
Sunbury +44 (0) 1932 743327 Walthamstow +44 (0) 208 919 4000 Letchworth +44 (0) 1462 667 700

Field Support Quality Assurance (UK)


Sunbury +44 (0) 1932 743327 Walthamstow +44 (0) 208 919 4000

Research & Development (UK) Manufacturing (UK)


Sunbury +44 (0) 1932 743333 Walthamstow +44 (0) 208 919 4000

Helpdesk Customer Services (UK)


Sunbury Walthamstow +44 (0) 208 919 6202
Tel: +44 (0) 1932 743327
Fax: +44 (0) 1932 743330

tepghelp@tycoint.com

Sunbury Walthamstow Letchworth


The Summit, Hanworth Road 160 Billet Road Dunhams Lane
Sunbury On Thames Walthamstow Letchworth
Middlesex London Herts.
TW16 5DB E17 5DR SG6 1BD
Telephone: +44 (0) 1932 743333 Telephone: +44 (0) 208 919 4000 Telephone: +44 (0) 1 462 667 700
Facsimile: +44 (0) 1932 743330 Facsimile: +44 (0) 208 919 4040 Facsimile: +44 (0) 1 462 667 777

The right is reserved to modify or withdraw any


product or service without notice
Product Catalogue PMC08 Issue 3
www.tycosafetyproducts-europe.com
Tyco Safety Products 2002

Vous aimerez peut-être aussi