WORKED EXAMPLE 2.

3
Bolted Slip Resistant Connection

Evaluate resistance of the bolted connection of a tie, shown in Figure 1WE2-3, with the slip on the
ultimate limit state. The steel is Grade S235. The bolts M 20, Grade 10.9, are preloaded (the bolt net
area As = 245 mm2) in holes 22. The material partial safety factors are Ms .ult = 1,10 , M 2 = 1,10
and Mb = 1,25 .

8
16
e 2 55
FRd FRd
p2 70
e 2 55

50 70 50 50 70 50 P 16 - 180 x 1200
e 1 p1 e 1 2 P 8 - 180 x 340
8 x M 20 -10.9
Figure 1WE2-3
__________________________________________________________________________________
Slip resistance
The design preloading force (net section of the bolt As = 245 mm2) Fp.Cd
is

Fp .Cd = 0 ,7 f ub As = 0 ,7 1 000 245 = 171,5 10 3 N . Fs.Rd

The slip factor is for surface blasted with shot = 0,5 (Class A
surface). There are two slip surfaces, as shown in Fig. 5.6.2. The
design slip resistance of one bolt under the ultimate limit state Figure 2WE2-3
(Connection Category C):
k n 1,0 2 0 ,50
Fs .Rd = s Fp ,Cd = 171,5 = 155 ,9 kN .
Ms .ult 1,10

Bearing resistance
The bearing resistance is derived for the plate 16 mm:

e1 50 bearing
= = = 0 ,758 (limit)
3 d0 3 22 Fb.Sd
p1 1 70 1
= = = 0 ,811 ,
3 d 0 4 3 22 4
f ub 1 000
= = = 2 ,778 ,
fu 360 Figure 3WE2-3
= 0 ,508 ,
2 ,5 f u d t 2 ,5 0 ,758 360 20 16
Fb .Rd = = = 174,6 10 3 N .
Mb 1,25

Net section
The design resistance of net cross section is

Anet f u 16 ( 180 2 22 ) 360


N net .Rd = 0 ,9 = 0 ,9 = 640 ,9 10 3 N .
M2 1,10

1
The connection resistance is 4 155,9 = 623,6 kN .

8 x M 20

55
70 2 P 8 - 180 x 340
55 8 22

50 70 50 50 70 50 P 16 - 180 x 1200
4 22
P 16 - 180 x 1000 Bolts 10.9
4 22 Contact surfaces blasted with shot, no painting
Steel S 235 J2
Scale: 1 : 10

Figure 4WE2-3 Design drawing of the connection

Prepared based on [Wald et al, 2001].