4.0 Clearances 7
6.0 Legislation 9
8.0 Emergency 11
Baxi Heating UK Ltd is a licensed member of the Benchmark Scheme which aims
to improve the standards of installation and commissioning of domestic heating
and hot water systems in the UK and to encourage regular servicing to optimise
safety, efficiency and performance.
Baxi Heating UK Ltd 2012 All rights reserved. No part of this publication may
be reproduced or transmitted in any form or by any means, or stored in any
retrieval system of any nature (including in any database), in each case whether
electronic, mechanical, recording or otherwise, without the prior written
permission of the copyright owner, except for permitted fair dealing under
Copyrights, Designs and Patents Act 1988.
0086
ISO 9001
FM 00866
2 1 12
3 11
4
10
2
5
Reset
9
PM
1
8
3
7
8
AM
0 4 0
5
bar
10
4
11 3
12 1 2
ON/OFF/Reset Display Central Heating Domestic Hot Water System Pressure Gauge Integral Timer
Selector Switch Temperature Control Temperature Control
OFF Position Central Heating & Hot Water Domestic Hot Water Reset
The boiler will not operate. Both Heating & Hot Water will operate. Hot Water will operate. Hold for approx 5 seconds and release.
Central Heating Indicator - The indicator will illuminate when the boiler is in the central
heating mode.
Domestic Hot Water Indicator - The indicator will illuminate when hot water is being
supplied to a tap or shower.
Burner On Indicator - The indicator will illuminate when the burner has fired and is heating
your central heating or domestic hot water.
Boiler Output Temperature - In either the central heating or domestic hot water position
Display the display will illuminate showing the current boiler temperature in degrees centigrade.
2
Central Heating System Pressure - The normal operating water pressure is shown when the
1 3 needle is in the GREEN section of the gauge, between 1 and 2.5 bar. If the pressure exceeds 3
0 4 bar (needle in the RED section) the safety pressure valve will operate and a fault is indicated.
bar Contact your Installer.
Burner On
YES Indicator
Display
NO
Is the Central Heating System YES Does the display show an error NO
Pressure needle in the GREEN code e.g. E133, E110 ?
section, between 1 and 2.5 bar ?
NO
1 3
0 4
bar
YES
If the reading falls below 1 bar
repressurise the system as
Turn the ON/OFF/Reset
described in section 3.1.
Selector Switch to Reset.
2 1 12
3 11
15 20
4 10
10
25
5
5
9
PM
8
7
7
8
AM
0
9
5
10
4
11 3
12 1 2
NO
25
5
CONTACT YOUR
INSTALLER OR
SERVICE ENGINEER.
1 3
2. With the system cold and the boiler not operating the
Fig. 1 0 4
pressure should be at least 0.5 bar. During operation the
bar pressure should not exceed 2.5 bar, and will normally be
between 1.0 and 2.0 (Fig. 1).
2
Normal Pressure
1 3 3. A pressure of 3 or greater indicates a fault. The safety
pressure relief valve will operate, at a pressure of 3 (Fig. 3). It is
Fig. 2 0 4 important that your Installer or Service Engineer is contacted
bar as soon as possible.
Requires
4. The minimum pressure for correct operation is 0.5. If the
Repressurising
2 pressure falls below 0.5, this may indicate a leak on the central
heating system (Fig. 2). Error Code E119 will be shown on the
1 3
display.
Fig. 3 0 4
bar
3.2 To Re-Pressurise the System
Fault 1. Look at the boiler from underneath. There will be two taps,
one connected to the cold inlet valve and one to the central
heating return valve. Do not operate these taps yet !
2. Your installer will have left a short copper pipe with wing
nuts (the filling loop) with you for safe keeping.
4. Ensure that the two seals are fitted, and connect the loop to
the taps with the wing nuts. These should be hand tightened.
6. Undo the two wing nuts, remove the loop and refit the
blanking caps. Put the loop in a safe place for future use, and
ensure that the seals remain in place
Top - 200mm
Bottom - 150mm*
Left side - 5mm
Right Side - 5mm
150mm Min*
Front - 5mm (In Operation)
- 450mm (For Servicing)
5mm Min
Fig. 4 In Operation
3
2 1 12
11
1. If a fault occurs on the boiler an error code may be shown
on the facia display (Fig. 5).
4
10
2
5
Reset
9
PM
1
8
3
7
7
8
AM
0 4 0
9
bar
10
10
7.1 Setting the Timer
Time Pointer
9
The Electro-Mechanical Timer allows the central heating
system to be set every 15 minutes.
8
Constant
Using the three position switch the timer will allow either
constant operation, timed operation or central heating off.
7
Timed
9
PM
AM
4
11 3
12 2
To set the timed heating program
1
The heating will operate when the white tappets are set to
the outer edge of the bezel.
Warning !
If you smell gas
Faulty boiler
In an Emergency
To activate your second year free warranty you must register your boiler with
heateam the service division of Baxi Heating UK Ltd either by completing and
returning the registration card or calling our telephone registration line on
0800 731 1644.
It is also a requirement of the warranty that the boiler has an annual service
(every 12 months) in accordance with the installation and servicing
Date of Installation instructions, performed by a Gas Safe registered engineer.
If you would like heateam to carry this out please call on 0844 871 1560.
What you need to do if you experience a problem with your heating system
or the operation of the boiler
You should always contact your installer first, because the cause of the fault
may not be related to the boiler. If your installer confirms that the fault is with
the boiler and he/she cant repair it, our friendly customer service team is on
hand to help. Simply call our service division heateam on 0844 871 1560 to
book an engineer visit or for any general advice that you may need. Our
contact centre is open Monday to Friday 8am - 6pm, weekends and Bank
Holidays 8.30am - 2pm, excluding Christmas Day and New Years Day.
When calling heateam it would be helpful if you could have the following
information to hand:-
Free of charge replacement of the complete unit provided always that the
failure is related to a manufacturing fault that cannot be repaired or is
uneconomic to repair.
Any damage caused by hard water scale deposits and/or aggressive water
resulting from corrosion.
All descriptions and illustrations provided in this leaflet have been carefully Faults caused by inadequate supply of electricity, gas or water to the property.
prepared but we reserve the right to make changes and improvements in
our products which may affect the accuracy of the information contained in Installations within commercial settings for which this boiler was not designed.
this leaflet. All goods are sold subject to our standard Conditions of Sale
which are available on request. Reimbursement of any third party repair or replacement costs that we havent
been told about or agreed with you in advance.