Vous êtes sur la page 1sur 1

PURDUE UNIVERSITY

ChE 43500 2015


DESIGN OF AN AIR EMISSION CONTROL SYSTEM

Air containing 5.7 vol % ammonia is produced by one of our processes. It is to be vented to the atmosphere
at a rate of up to 3500 scfm but must contain less than 100 ppm (molar) ammonia to meet our air permit
requirements. Design a scrubber system to remove the ammonia. The Plant Manager has recommended a
tower packed with Raschig rings as compatible with our current emission control systems.
We would like to sell the recovered ammonia, so investigate process concepts to create a commercially
viable ammonia product. This is not a high cash flow business and effort should be expended to minimize
capital requirements.

Pilot Plant Equipment


Our pilot plant facility has a small packed Hydroxide content. You should titrate the weak
column absorber which is available for your use. base with standardized acid using a methyl orange
The column (10 cm I.D.) is packed with indicator. The original process equipment handout
approximately 5 L, 4.3 kg, of ceramic from 1999 is available, but the equipment has been
Raschig rings. extensively revised since that time. Apply statistics
Air is fed to the bottom of the column and water and error analysis.
to the top. Gaseous ammonia can be injected into
the inlet air stream shortly before it enters the Equipment Characterization
column and its flow rate is monitored with a Determine pressure drop/flooding conditions in the
Rota meter. A gas sample tap is located in the column under varying gas and liquid flow rates.
headspace at the top of the column. An ammonia Apply statistical and error analysis to your data and
analyzer with an infrared detector continuously report findings, together with an experimental
withdraws a sample of this stream with a design and plan to continue with the design of your
calibrated air pump. The sample stream must be scaled up equipment.
free of liquid water, so it is sent through a water
trap. This apparatus is designed to detect trace Safety
(ppm) levels of ammonia in air so do not use it to Ammonia is a powerful chemical. Carefully read
calibrate the ammonia Rotameter. High spikes and review the MSDS before beginning any
of ammonia in air will result in several hours of experimental activity. Cylinders of ammonia gas
wasted time until the air clears the sample are potentially dangerous because of the quantity
stream. of material. Before starting work, be sure the
exhaust duct over the gas exit is working.
Ammonia Concentration in Liquid Effluent

The liquid product stream from the absorber


column should be analyzed for ammonium

References
1. McCabe, W.L., J.C. Smith, and P. Harriott, Unit Operations of Chemical Engineering, 7th ed,
McGrawHill,2005.
2. Wankat,PhillipC.,SeparationProcessEngineering,3rded.,PrenticeHall,2012.
3. Houze, R.N., Notes on Mass Transfer, Purdue University, 2006

Vous aimerez peut-être aussi