Académique Documents
Professionnel Documents
Culture Documents
Non-Spring Return
ISO 9001
Direct Coupled Actuators
ML6161, ML7161
ML6174, ML7174
SPECIFICATION DATA
The 35 and 70 lb-in. Non-Spring Return Direct Coupled FEATURES
Actuators (DCA) are control motors that provide floating or
proportioning control for valves and dampers. The proportioning
45, 60, and 90 selectable stroke in either clockwise
motors accept a current or voltage signal from a controller to
(cw) or counterclockwise (ccw) directions.
position the damper or valve at any chosen point between fully
Magnetic coupling eliminates the need for mechanical
open and fully closed.
stops.
Two field-addable auxiliary switches.
Auxiliary feedback potentiometer field-addable on
SPECIFICATIONS select models.
0 to 30 minimum position adjustment (cw or ccw
direction) on all models.
Electrical Ratings: Manual declutch on select models.
Power Input: 24 Vac 20%, 50/60 Hz. W7620 Terminal Unit Controller compatibility.
Model Power Consumption Commercial Zone Damper in W7600 Commercial Zone
System compatibility.
q ML6161A,B,C,D 1.8 VA
q ML7161A 4.8 VA
q ML6174A,B 2.4 VA Actuator Timing for 90 Stroke:
q ML7174A 5.4 VA At 50 Hz At 60 Hz
q 90 Second Models 108 sec 90 sec
Auxiliary Switch Ratings:
q Electrical selective NO or NC, not simultaneous. q Three-Minute Models 216 sec 180 sec
q Pilot Duty: 50 VA, 24 Vac. q Seven-Minute Models 504 sec 420 sec
q Switch Differential: Three angular degree maximum.
Noise Output:
q 45 dBA at 1 meter maximum.
Models:
TYPICAL SPECIFICATION
ML Motor Linkage
Non-spring return actuator shall be direct coupled type
q 61 Floating Control
that requires neither crankarm nor linkage and be capable
q 71 4-20 mA/2-10 Vdc Control of direct mounting to a 3/8 inch or 1/2 inch diameter
q 61 35 lb-in. (4 Nm), Non-Spring Return jackshaft. The actuator shall connect to the shaft using
q 71
74 70 lb-in. (8 Nm), Non-Spring Return set screws. The actuator must provide floating or
proportional control.
q A Includes output for feedback
The actuator design must be for use in either clockwise
potentiometer.
or counterclockwise operation.
q B Standard (includes minimum Actuators shall use a true synchronous ac stepper motor
position setscrews) to drive the output hub. Run time shall be constant and
q C Includes output for feedback independent of load, temperature and supply voltage
potentiometer and cover w/ (within product-family specifications). Overload
conduit connections. protection shall be provided at all angles of rotation by a
q D Includes cover w/ conduit magnetic clutch mechanism that provides an absolute
connections. limit to the output torque without a physical link between
q E Standard with European the motor and the gear train.
ratings. Actuators shall have a minimum performance of 40,000
full-stroke powered cycles, and 1,500,000 repositions
q 1 Standard documented in the product data literature. Actuators shall
q 2 Includes declutch be UL and CSA listed, manufactured under ISO 9001
function International Quality Control Standards.
ML XXX Varies by Model
Approvals:
q Underwriters Laboratories Inc. Component Recognized:
File No. E4436; Guide No. XAPX2.
CW q Meets UL94-5V plenum requirements.
4-7/8 q Canadian Standards Association Certified (includes
(123)
COM auxiliary switch).
CCW
4-1/4
(108)
Accessories:
q 200976A Auxiliary Potentiometer (0 to 500 ohm).
q 200976C Auxiliary Potentiometer (0 to 2000 ohm).
q 201052A Auxiliary Switch (one).
q 201052B Auxiliary Switch (two).
q 4074ENJ Bag Assemblyincludes stop pin, shaft adapter,
and two minimum position screws.
q 4074ENY Bag Assemblyincludes stop pin and shaft
adapter.
q 4074EVK Short Shaft Extender.
q 7640QW Metal Enclosurefor attaching conduit to
11/16 actuator.
(18) q T641 Floating Thermostatfor use with seven-minute
models.
q T6984 Floating Thermostatfor use with 90-second and
3-3/8 (86)
M14227
seven-minute models.
q T7984 Modulating Thermostatfor use with ML7174.
By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your
use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and
against any liability, cost, or damages, including attorneys fees, arising out of, or resulting from, any modification to
the literature by you.