Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT
SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE
OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required
to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be
determined by turning the equipment off and on, users are encouraged to try to correct the interference by using one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCBs public
domain version of the UNIX operating system. All rights reserved. Copyright 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
Cisco and the Cisco Logo are trademarks of Cisco Systems, Inc. and/or its affiliates in the U.S. and other countries. A listing of Cisco's trademarks can be found at
www.cisco.com/go/trademarks. Third party trademarks mentioned are the property of their respective owners. The use of the word partner does not imply a partnership
relationship between Cisco and any other company. (1005R)
Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the
document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.
Audience
This guide is for the person installing the Cisco Metro Ethernet (ME) 3800X and ME 3600X Series
switch, also known as the switch.
Purpose
This guide describes the hardware features of the switch. It describes the physical and performance
characteristics of the switch, explains how to install it, and provides troubleshooting information.
This guide does not describe system messages that you might receive or how to configure your switch.
For more information, see the switch software configuration guide, the switch command reference, and
the switch system message guide on Cisco.com at:
http://www.cisco.com/go/me3800x_docs
Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in
this manual.
Caution Means reader be careful. In this situation, you might do something that could result in equipment
damage or loss of data.
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this
device. Statement 1071
The safety warnings for this product are translated into several languages in the Regulatory Compliance
and Safety Information for the Cisco ME 3800X and ME 3600X Switches on Cisco.com. The EMC
regulatory statements are also included in that guide.
Related Publications
These documents provide information about the switches and are available from this Cisco.com site:
http://www.cisco.com/go/me3800x_docs
Release Notes for the Cisco ME 3800X and ME 3600X Switch
Note Before installing, configuring, or upgrading the switch, see the release notes on Cisco.com for
the latest information.
These compatibility matrix documents are available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix
Cisco 100-Megabit Ethernet SFP Modules Compatibility Matrix
Cisco CWDM SFP Transceiver Compatibility Matrix
Cisco Small Form-Factor Pluggable Modules Compatibility Matrix
Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable Modules
The Cisco Metro Ethernet (ME) 3600X switch is an Ethernet access switch.
The Cisco ME 3800X switch is a carrier Ethernet aggregation switch.
Throughout this document, the Cisco ME 3800X and ME 3600X are referred to as the switch.
Setting Up the Switch, page 1-1
Switch Models, page 1-1
Front Panel, page 1-2
Rear Panel, page 1-10
Power Supply Module Features, page 1-11
Fan Module, page 1-12
Management Options, page 1-13
Switch Models
You can deploy the switch as a backbone switch, aggregating 10BASE-T, 100BASE-TX, 1000BASE-T,
and fiber-optic Ethernet traffic from other network devices.
See the switch software configuration guide for examples that show how you might deploy the switch in
your network.
Front Panel
Note The front panel is the same for the Cisco ME 3800X-24FS-M and Cisco ME 3600X-24FS-M.
1 5 6
SYST
M GM T BITS
PS IN 1 SYNC M GM T
PS IN 2 ALM 1
PS/FA N ALM 2 1
1 2
PS/FA N ALM 3 3
2 4 5
ALM 4 6 7
SD CARD 8 9
10 11
12
13
14 15
16 17
ALAR M S 18 19
C O NSO 20 21
LE 22 23
24
2X
207443
12X
14X
1
24X
2
2 3 4
7
8
Figure 1-2 shows the Cisco ME-3600X-24TS-M. The copper 10/100/1000Base-T/TX downlink ports are
grouped in pairs. The first member of the pair (port 1) is above the second member (port 2). Port 3 is
above port 4, and so on.
1 5 6
SYST
M GM T BITS
PS IN 1 SYNC M GM T
PS IN 2 ALM 1
PS/FA N ALM 2
1
PS/FA N ALM 3 1X 1 2
2 3 4
ALM 4 5 6
SD CARD 7 8
9 10
11 12
11X
13X 13 14
15 16
ALAR M S 17 18
C O NSO 19 20
LE 21 22
23 24
23X
2X
207474
12X
14X
1
24X
2
2 3 4
7
8
BITS Port
The Building Integrated Timing Supply (BITS) port is an RJ-45 interface that provides external
synchronized clocking through a timing signal generator (TSG). The BITS input is an external timing
reference that must be traceable to a stratum 3 clock or better. The BITS port on the switch can be
configured to accept either a T1 or an E1 framed input. Although this clock input is T1 or E1 framed, it
does not carry data and cannot be used for any other purpose than to derive clocking for the system.
For more information on configuring interfaces, see the switch software configuration guide.
For more information about SFP+ and SFP modules, see your SFP+ and SFP module documentation and
the Installing and Removing SFP+ and SFP Modules section on page 2-15. For cable specifications,
see Appendix B, SFP and SFP+ Module Connectors.
SD Memory Slot
The switch has an SD (secure digital) memory slot for additional non-volatile storage. You can save
configurations or Cisco IOS images and transfer them to other systems. The memory slot supports
standard SD (1 MB and 2 GB) memory cards or SDHC (4 GB) memory cards.
LEDs
You can use the switch system and port LEDs to monitor switch activity and performance.
Switch LED Panels, page 1-7
System LED Description, page 1-7
Power Supply Module Input LED Description, page 1-8
Power Supply and Fan LED Description, page 1-8
Ethernet Management Port LED Description, page 1-8
Alarm LEDs Description, page 1-9
Sync LED Description, page 1-9
SD Card LED Description, page 1-9
Port LEDs Description, page 1-10
1 SYST MGMT 7
SYNC 8
2 PS IN 1 ALM 1 9
3 PS IN 2 ALM 2 10
4 PS/FAN 1 ALM 3 11
5 PS/FAN 2 ALM 4 12
6 SD CARD
207445
1 SYST (system) LED 7 MGMT (Ethernet management port) LED
2 PS IN 1 (power supply module 1 input) LED 8 SYNC LED
3 PS IN 2 (power supply module 2 input) LED 9 ALM 1 (alarm input 1) LED
4 PS/FAN 1 (power supply module output or fan 10 ALM 2 (alarm input 2) LED
module 1) LED
5 PS/FAN 2 (power supply module output or fan 11 ALM 3 (alarm input 3) LED
module 2) LED
6 SD CARD LED 12 ALM 4 (alarm input 4) LED
Rear Panel
Note The rear panel is the same for the Cisco ME 3800X and ME 3600X switches.
The rear panel on the switch has two power supply module slots and a ground connector. Power supply
module slots can accept AC or DC input power supply or a fan module. See Figure 1-4.
207444
1
2
3
Caution Both slots must be occupied either by two power supply modules or a power supply and a fan module.
Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module.
Running the switch with an empty slot triggers an alarm.
Each power supply module contains three fans. The switch can operate safely if one fan fails. A fan
failure triggers an alarm. When a fan fails, replace the power supply module immediately.
See Chapter 3, Installing and Removing AC and DC Input Power Supply and Fan Modules, for
instructions on installing the AC and DC input power supply and fan module. See Appendix A,
Technical Specifications, for voltage and other specifications.
PPSUSUOK
INPUT
207476
1 Power supply module status LED 2 Power supply input status LED
Fan Module
The fan module provides cooling and proper airflow when only one power supply module is installed.
The fan module is hot-swappable.
Caution Both slots must be occupied either by two power supply modules or a power supply and a fan module.
Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module.
Running the switch with an empty slot triggers an alarm.
Each fan module contains three fans. The switch can operate safely if one fan fails. A fan failure triggers
an alarm. When a fan fails, replace the fan module immediately.
FAN
207477
1 Fan module LED
Management Options
Cisco IOS CLI
You can fully configure and monitor the switch from the CLI. You can access the CLI either by
connecting your management station directly to the switch console port or by using Telnet from a
remote management station. See the switch command reference on Cisco.com for more information.
For setup instructions that use the CLI, go to Appendix C, Configuring the Switch with the
CLI-Based Setup Program.
CiscoView application
The CiscoView device-management application displays the switch image so that you can set
configuration parameters and view switch status and performance information. The CiscoView
application, which you purchase separately, can be a standalone application or part of a Simple
Network Management Protocol (SNMP) platform. See the CiscoView documentation for more
information.
Network Configurations
See the switch software configuration guide on Cisco.com for an explanation of network configuration
concepts. The software configuration guide also provides examples of network configurations that use
the switch to create dedicated network segments that are interconnected through Ethernet connections.
Warnings
These warnings are translated into several languages in the Regulatory Compliance and Safety
Information for the Cisco ME 3800X and ME 3600X Switches document that ships with the switch.
These warning statements apply to all the switches:
Warning Before working on equipment that is connected to power lines, remove jewelry (including rings,
necklaces, and watches). Metal objects will heat up when connected to power and ground and can
cause serious burns or weld the metal object to the terminals. Statement 43
Warning Do not stack the chassis on any other equipment. If the chassis falls, it can cause severe bodily injury
and equipment damage. Statement 48
Warning Ethernet cables must be shielded when used in a central office environment. Statement 171
Note Ethernet cables must be shielded and grounded at both ends when they are used in a central office
environment.
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Warning Read the installation instructions before connecting the system to the power source. Statement 1004
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to
ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest
component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in
the rack. Statement 1006
Warning There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with
the same or equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturers instructions. Statement 1015
Warning This unit is intended for installation in restricted access areas. A restricted access area can be
accessed only through the use of a special tool, lock and key, or other means of security.
Statement 1017
Warning The plug-socket combination must be accessible at all times, because it serves as the main
disconnecting device. Statement 1019
Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning For connections outside the building where the equipment is installed, the following ports must be
connected through an approved network termination unit with integral circuit protection.
10/100/1000 Ethernet Statement 1044
Warning When installing or replacing the unit, the ground connection must always be made first and
disconnected last. Statement 1046
Warning Installation of the equipment must comply with local and national electrical codes. Statement 1074
Caution The intra-building port(s) of the equipment or subassembly is suitable for connection to intrabuilding or
unexposed wiring or cabling only. The intra-building port(s) of the equipment or subassembly MUST
NOT be metallically connected to interfaces which connect to the OSP or its wiring. These interfaces are
designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE, Issue 5) and require isolation from the exposed OSP cabling. The addition of Primary
Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.
You can use the grounding lug to attach a wrist strap for ESD protection during servicing.
Warning To prevent the system from overheating, do not operate it in an area that exceeds the maximum
recommended ambient temperature of:
122F (50C) Statement 1047
Warning This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Installation Guidelines
Before installing the switch, verify that these guidelines are met:
For Ethernet ports and 1000BASE-T SFP module ports, cable lengths from the switch to connected
devices can be up to 328 feet (100 meters).
For cable requirements for SFP+ and SFP module connections, see the Cable Pinouts section on
page B-7.
Operating environment is within the ranges listed in Appendix A, Technical Specifications.
Front-panel indicators can be easily read, and access to ports is sufficient for unrestricted cabling.
AC power cord reaches from the power outlet to the connector.
Cabling is away from sources of electrical noise, such as radios, power lines, and fluorescent
lighting fixtures. Make sure that the cabling is safely away from other devices that might damage
the cables.
Airflow around the switch and through the vents is unrestricted.
Note If the switch is installed in a closed or multirack assembly, the temperature around it might be
greater than normal room temperature.
Before you connect the switch to a power source, note the power consumption specifications in
Appendix A, Technical Specifications.
Rack-Mounting
To install the switch in a 19-inch, 23-inch, or a European Telecommunications Standards Institute (ETSI)
rack, follow these instructions. (The ETSI racks require optional mounting hardware.)
Attaching Brackets to the Switch, page 2-6
Mounting in a Rack, page 2-11
Warning To prevent bodily injury when mounting or servicing this unit in a rack, you must take special
precautions to ensure that the system remains stable. The following guidelines are provided to
ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest
component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in
the rack. Statement 1006
4
207472
For 19-inch racks, use part number RCKMNT-ME3KX-19IN (see Figure 2-2 on page 2-7).
For 23-inch racks, use part number RCKMNT-ME3KX-23IN (see Figure 2-3 on page 2-8).
For ETSI racks, use part number RCKMNT-ME3KX-ETSI (see Figure 2-4 on page 2-9).
For 23-inch racks using the angle bracket, use part number RCKMNT-ME3KX-ANG
(see Figure 2-5 on page 2-10).
Figure 2-2 shows how to attach brackets for 19-inch racks on the switch.
207495
4
1
Figure 2-3 shows how to attach brackets for the 23-inch racks on the switch.
207496
4
1
Figure 2-4 shows how to attach brackets for the ETSI racks on the switch.
207498
4
1
Figure 2-3 shows how to attach the angle brackets for 23-inch racks on the switch.
Note Use the holes marked R to install the bracket on the right side; use the holes marked L to install the
bracket on the left side.
279252
1 Phillips flat-head screws 2 Mid-mounting position
Mounting in a Rack
After the brackets are attached on the switch, use the four supplied number-12 Phillips machine screws
to securely attach the brackets to the rack. See Figure 2-6 for standard rack-mounting using the 19-inch,
23-inch, and ETSI brackets. See Figure 2-7 for rack-mounting using the angle-bracket.
SYST
M GM T BITS
PS IN 1 SYNC M GM T
PS IN 2 ALM 1
PS/FA N ALM 2 1
1 2
PS/FA N ALM 3 3
2 4 5
ALM 4 6 7
SD CARD 8 9
10 11
12
13
14 15
16 17
ALAR M S 18 19
C O NSO 20 21
LE 22 23
24
2X
12X
14X
1
24X
2
SYST
M GM T BITS
PS IN 1 SYNC M GM T
PS IN 2 ALM 1
PS/FA N ALM 2 1
1 2
PS/FA N ALM 3 3
2 4 5
ALM 4 6 7
SD CARD 8 9
10 11
12
13
14 15
16 17
ALAR M S 18 19
C O NSO 20 21
LE 22 23
24
2X
207499
2 12X
14X
1
24X
2
After the switch is mounted in the rack, you need to do these tasks to complete the installation:
Power on the switch. See the Verifying Switch Operation section on page 2-4.
Connect to the console port, and run the initial configuration. See the Cisco ME 3800X and
ME 3600X Switch Getting Started Guide for instructions.
Connect to the front-panel ports. See the Connecting to the 10/100/1000 Ports section on
page 2-19 and the Connecting to Fiber-Optic SFP+ and SFP Modules section on page 2-20.
We recommend attaching the cable guide to prevent the cables from obscuring the front panel of the
switch and the other devices installed in the rack. Use the supplied black screw shown in Figure 2-6
to attach the cable guide to the left or right bracket.
For configuration instructions about using the CLI setup program, go to Appendix C, Configuring the
Switch with the CLI-Based Setup Program.
Warning Suitable for mounting on and over a concrete or other non-combustible surface only. Statement 345
Note The front of the switch extends approximately 5 inches from the front of the rack (including space for
cables), and the rear of the switch extends approximately 10 inches into the rack.
279253
After the switch is mounted in the rack, you need to do these tasks to complete the installation:
Power on the switch. See the Verifying Switch Operation section on page 2-4.
Connect to the console port, and run the initial configuration. See the Cisco ME 3800X and
ME 3600X Switch Getting Started Guide for instructions.
Connect to the front-panel ports. See the Connecting to the 10/100/1000 Ports section on
page 2-19 and the Connecting to Fiber-Optic SFP+ and SFP Modules section on page 2-20.
For configuration instructions about using the CLI setup program, go to Appendix C, Configuring the
Switch with the CLI-Based Setup Program.
Wall-Mounting
Attaching Brackets for Wall-Mounting, page 2-13
Mounting the Switch on a Wall, page 2-14
1
22 23
24
1
24X
2
207931
Follow the same steps to attach the second bracket to the opposite side.
Warning Read the wall-mounting instructions carefully before beginning installation. Failure to use the
correct hardware or to follow the correct procedures could result in a hazardous situation to people
and damage to the system. Statement 378
Mount the switch with the side panel facing up (Figure 2-9).
10 11
2
1
24X
14X
12X
2X
CONSOLE
ALARMS
1
ALM 4
ALM 3
ALM 2
ALM 1
SD CARD
PS/FAN 2
PS/FAN 1
207932
PS IN 2
PS IN 1
1 User-supplied screws
Table- or Shelf-Mounting
Follow these steps to install the switch on a table or a shelf:
For configuration instructions about using the CLI setup program, go to Appendix C, Configuring the
Switch with the CLI-Based Setup Program.
Note When the connectors are not being used, replace the dust covers on them for protection.
Caution We strongly recommend that you do not install or remove fiber-optic SFP+ or SFP modules with cables
attached because of the potential damage to the cables, the cable connector, or the optical interfaces in
the SFP+ or SFP module. Disconnect all cables before removing or installing an SFP+ or SFP module.
Removing and installing an SFP+ or SFP module can shorten its useful life. Do not remove and insert
SFP+ or SFP modules more often than is absolutely necessary.
Step 1 Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2 Find the send (TX) and receive (RX) markings that identify the top side of the SFP+ or SFP module.
On some SFP+ and SFP modules, the send and receive (TX and RX) markings might be replaced by
arrows that show the direction of the connection, either send or receive (TX or RX).
Step 3 Align the SFP+ or SFP module in front of the slot opening and push until you feel the connector on the
module snap into place in the rear of the slot (see Figure 2-11).
207469
2
Step 4 For fiber-optic SFP+ or SFP modules, remove the dust plugs from the optical ports, and store them for
later use.
Caution Do not remove the dust plugs from the fiber-optic SFP+ or SFP module port or the rubber caps from the
fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP+ or SFP
module ports and cables from contamination and ambient light.
Step 5 Insert the LC or MT-RJ cable connector into the SFP+ or SFP module.
207470
2
1 Bale clasp
Step 5 Grasp the SFP+ or SFP module, and carefully remove it from the module slot.
Step 6 For fiber-optic SFP+ or SFP modules, insert a dust plug into the optical ports of the SFP+ or SFP module
to keep the optical interfaces clean.
Step 7 Place the removed SFP+ or SFP module in an antistatic bag or other protective environment.
To insert an SFP+ module patch cable into the SFP+ module slot, follow these steps:
Step 1 Attach an ESD-preventive wrist strap to your wrist and to a bare metal surface.
Step 2 Insert the SFP+ module patch cable into the slot until you feel the connector on the cable snap into place
in the rear of the slot (see Figure 2-13).
Figure 2-13 Inserting an SFP+ Module Patch Cable into an SFP+ Module Slot
207500
2
Step 3 Repeat these steps for the second switch to which you want to connect the first switch.
Figure 2-14 Connecting Two Switches with an SFP+ Module Patch Cable
SYST
M GM T BITS
PS IN 1 SYNC M GM T
PS IN 2 ALM 1
PS/FA N ALM 2 1
1 2
PS/FA N ALM 3 3
2 4 5
ALM 4 6 7
SD CARD 8 9
10 11
12
13
14 15
16 17
ALAR M S 18 19
C O NSO 20 21
LE 22 23
24
2X
12X
14X
SYST
M GM T BITS
SYNC M GM T 1
PS IN 1
24X
PS IN 2 ALM 1
PS/FA N ALM 2 2
1 1
PS/FA N ALM 3 2 3
2 4 5
ALM 4 6 7
SD CARD 8 9
10 11
12
13
14 15
16 17
ALAR M S 18 19
C O NSO 20 21
LE 22 23
24
2X
207501
12X
14X
1
24X
2
To remove an SFP+ module patch cable from the SFP+ module slot, release the connector, and pull it
from the SFP+ module slot.
Step 1 When connecting to workstations, servers, and routers, connect a straight-through cable to an RJ-45
connector on the front panel. (See Figure 2-15.) When connecting to switches or repeaters, use a
crossover cable. (See the Cables and Adapters section on page B-5 for cable-pinout descriptions.)
Note You can use the mdix auto interface configuration command in the CLI to enable the automatic
medium-dependent interface crossover (auto-MDIX) feature. The switch then detects the required cable
type for copper Ethernet connections and configures the interfaces accordingly. Therefore, you can use
either a crossover or a straight-through cable for connections to a copper 10/100/1000 or 1000BASE-T
SFP module port on the switch, regardless of the type of device on the other end of the connection.
Step 2 Connect the other end of the cable to an RJ-45 connector on the other device. The port LED turns on
when both devices have established link. (See Figure 2-15.)
1X 1 2
3 4
5 6
7 8
9 10
11 12
11X
2X
207933
12X
The port LED is amber while Spanning Tree Protocol (STP) discovers the topology and searches for
loops. This takes about 30 seconds, and then the port LED turns green. If the port LED does not turn
green, the device at the other end might not be turned on, or there might be a cable problem or a problem
with the adapter installed in the attached device. See Chapter 4, Troubleshooting, for solutions to
cabling problems.
Step 3 Reconfigure and reboot the connected device, if necessary.
Step 4 Repeat Steps 1 through 3 to connect each device.
Caution Do not remove the rubber plugs from the SFP+ or SFP module port or the rubber caps from the
fiber-optic cable until you are ready to connect the cable. The plugs and caps protect the SFP+ or SFP
module ports and cables from contamination and ambient light.
Before connecting to the SFP+ or SFP module, be sure that you understand the port and cabling
stipulations in the Installation Guidelines section on page 2-4 and in the SFP+ and SFP Modules
section on page 1-4. See Appendix B, Connector and Cable Specifications, for information about the
LC on the SFP+ or SFP module.
Step 1 Remove the rubber plugs from the module port and fiber-optic cable, and store them for future use.
Step 2 Insert one end of the fiber-optic cable into the SFP+ or SFP module port (see Figure 2-16).
207471
2
Step 3 Insert the other cable end into a fiber-optic connector on a target device.
Step 4 Observe the port status LED.
The LED turns green when the switch and the target device have an established link.
The LED turns amber while the STP discovers the network topology and searches for loops. This process
takes about 30 seconds, and then the port LED turns green.
If the LED is off, the target device might not be turned on, there might be a cable problem, or there might
be problem with the adapter installed in the target device. See Chapter 4, Troubleshooting, for
solutions to cabling problems.
Step 5 If necessary, reconfigure and restart the switch or target device.
Where to Go Next
You can use the default configuration or use any of the management options described in the
Management Options section on page 1-13 to change the switch settings.
This chapter provides the installation and removal instructions for the AC and DC input power supply
and fan modules for the Cisco ME 3800X and ME 3600X switches. Your switch ships with at least one
power supply module installed, either AC or DC, depending on your order. The power supply and fan
modules are field-replaceable units (FRUs).
Note The power supply and fan modules are hot-swappable devices.
For translations of the safety warnings in this chapter, see the Regulatory Compliance and Safety
Information for the Cisco ME 3800X and ME 3600X Switch on Cisco.com.
Power Supply Module Description, page 3-1
Fan Module Description, page 3-3
Connector-Side Description, page 3-3
Power Supply and Fan Module Installation, page 3-4
The AC input power supply module is an autoranging unit that supports input voltages between
100 and 240 VAC. The AC power supply module ships with a power cord to connect to an AC power
outlet.
The DC input power supply module has a single input feed and supports input voltages from 18 to
32 VDC or 36 to 72 VDC. The DC power supply module ships with a terminal block to be wired for DC
power outlet connections. The terminal block is covered by a clear plastic block cover that snaps onto
the terminal block. You must remove the block cover before you work with the wires. The block cover
is slotted so that the wires can exit only one end. If you want the wires to exit in a different direction,
remove the block cover, rotate it, and snap it back on.
Each power supply module is cooled by three internal fans. A fan failure triggers an alarm. When a fan
fails, replace the power supply module immediately.
Caution Both slots must be occupied either by two power supply modules or a power supply and a fan module.
Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module.
Running the switch with an empty slot triggers an alarm.
1
2
PSU OK
AC
207446
3
4
5 6
1
2
PSU OK
AC
207447
3
4
5
6
The fan module provides cooling and proper airflow when only one power supply module is installed.
Caution Both slots must be occupied either by two power supply modules or a power supply and a fan module.
Do not run the switch with an empty slot unless you are replacing a faulty power supply or fan module.
Running the switch with an empty slot triggers an alarm.
Each fan module contains three fans. The switch can operate safely if one fan fails. A fan failure triggers
an alarm. When a fan fails, replace the fan module immediately.
1
2
FAN
3 207448
Connector-Side Description
Figure 3-4 shows the connector side of the power supply and fan module, which connects to the switch
rear panel through its power supply module slot.
1 1 1
207449
2
Installation Guidelines
Observe these guidelines when you install a fan or power supply module:
Do not force the fan or power supply module into the slot. This can damage the pins on the switch
if they are not aligned with the unit.
A fan or power supply module that is only partially connected to the switch can disrupt the system
operation.
Verify that you are using the correct power cord.
Warning Do not reach into a vacant slot or chassis while you install or remove a module or a fan. Exposed
circuitry could constitute an energy hazard. Statement 206
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning Do not work on the system or connect or disconnect cables during periods of lightning activity.
Statement 1001
Caution To prevent overheating and to maintain proper air flow, either a power supply module or a fan module
must be installed in each power supply module slot at all times. Never operate the switch for extended
periods of time without either a power supply module or a fan module installed in each power supply
module slot.
AC-1 PSU-1
280937
AC-2 PSU-2
Step 1 Verify that the power from the power source is off.
Step 2 Insert the new power supply module in the power supply module slot, and gently push it into the slot
(see Figure 3-6). When correctly inserted, the power supply module is flush with the switch rear panel.
PSU OK
207478
AC
Step 3 Align the two captive screws with the screw holes in the panel. Use a ratcheting torque screwdriver to
torque each screw to 10 in-lb.
Step 4 Connect the AC power cord to the power supply module and to an AC power outlet.
Step 5 (Optional) Attach the power-cord retainer clip to the power supply module and thread the plastic bushing
until it is snug against the plug (Figure 3-7).
278366
Step 6 Turn on the power at the power source and set the power supply module switch to ON.
Step 7 From the front of the switch, confirm that the PS IN and the PS/FAN LEDs are green. If you can access
the switch rear panel, verify that the PSU and INPUT LEDs are green. See the Power Supply Module
LEDs section on page 1-11 for a description of the power supply module LEDs. See the Switch LED
Panels section on page 1-7 for system LED descriptions.
Caution Do not leave the power supply slot open for more than:
- 5 minutes provided the ambient temperature is 25C and at 5000 feet or lower elevation
- 90 seconds in all other conditions.
Step 5 Remove the power supply module from the power slot by pulling on the extraction handle.
Warning An exposed wire lead from a DC-input power source can conduct harmful levels of electricity. Be sure
that no exposed portion of the DC-input power source wire extends from the terminal block plug.
Statement 122
Warning Before connecting or disconnecting ground or power wires to the chassis, ensure that power is
removed from the DC circuit. To ensure that all power is OFF, locate the circuit breaker on the panel
board that services the DC circuit, switch the circuit breaker to the OFF position, and tape the switch
handle of the circuit breaker in the OFF position. Use a voltmeter to test for 0 (zero) voltage at the
power terminals on the chassis. Statement 196
Caution Installation of the equipment must comply with local and national electrical codes.
Note We recommend that you use 14 or 16 AWG copper wiring for Network Equipment Building Systems
(NEBS) installation, following the guidelines for DC power wiring in the central office.
Note You can use the grounding lug to attach a wrist strap for ESD protection during servicing.
Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection
authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024
Warning When installing or replacing the unit, the ground connection must always be made first and
disconnected last. Statement 1046
Caution To make sure that the equipment is reliably connected to earth ground, follow the grounding
procedure instructions, and use a UL-listed lug suitable for number-6 AWG wire and two number-10-32
ground-lug screws.
Follow these steps to install a dual-ground lug on the switch. Make sure to follow any grounding
requirements at your site.
Step 1 Locate the dual-hole lug that ships with the switch.
Step 2 If your ground wire is insulated, use a wire stripping tool to strip the 6 AWG ground wire to 0.875 inch
(12.7 mm) 0.02 inch (0.5 mm).
1
254820
2 3
1 0.875 inch (12.7 mm) 0.02 inch (0.5 mm) 3 Wire lead
2 Insulation
Step 3 Slide the open end of the ground lug over the exposed area of the wire.
Step 4 Crimp the ground lug to the wire (see Figure 3-9).
280938
Step 5 Attach the dual-hole lug and the wire assembly to the chassis ground connection with the supplied
screws (Figure 3-10).
207475
Step 6 Use a ratcheting torque Phillips-head screwdriver to torque the ground-lug screws to 32 in-lb.
Step 7 Connect the other end of the grounding wire to an appropriate grounding point at your site or to the rack.
Step 1 To ensure that power is removed from the DC circuits, locate the circuit breakers for the DC circuits,
switch the circuit breakers to the OFF position, and tape the circuit-breaker switches in the OFF position.
Step 2 Insert the new power supply module into the power supply module slot, and gently push it into the slot
(Figure 3-11). When correctly inserted, the power supply module is flush with the switch rear panel.
PSU OK
AC
PSU OK
207479
AC
Step 3 Align the two captive screws with the screw holes. Use a ratcheting torque Phillips-head screwdriver to
torque each screw to 10 in-lb.
Step 4 Connect the input power as described in the Wiring the DC Input Power Source section.
Warning This product relies on the buildings installation for short-circuit (overcurrent) protection. Ensure that
the protective device is rated not greater than:
24VDC 30A
48VDC 15A Statement 1005
Warning A readily accessible two-poled disconnect device must be incorporated in the fixed wiring.
Statement 1022
Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Caution The DC power supply module voltage should be within 18 to 32 VDC or 36 to 72 VDC. If the supply
voltage is not in this range, the switch might not operate properly or might be damaged.
Step 1 To ensure that all power is OFF, locate the circuit breaker that services the DC circuit, switch the circuit
breaker to the OFF position, and tape the switch handle of the circuit breaker in the OFF position.
Step 2 Remove the terminal block cover.
Note The terminal block is covered by a clear plastic block cover that snaps onto the terminal block.
You must remove the block cover before you work with the wires. The block cover is slotted so
that the wires can exit only one end. If you want the wires to exit in a different direction, remove
the block cover, rotate it, and snap it back on.
Step 3 Using a wire-stripping tool, strip each of the wires coming from the DC input power source to 0.350 inch
(8.9 mm) 0.02 inch (0.5 mm).
254820
2 3
1 0.350 inch (8.9 mm) 0.02 inch (0.5 mm) 3 Wire lead
2 Insulation
Step 4 Crimp the fork-type terminals to the 14 or 16 AWG DC power input wires.
Step 5 Connect the wires to the DC input power terminals as shown in Figure 3-13. Make sure to match the
polarity (negative to negative, positive to positive) when connecting the wires to the terminal.
Figure 3-13 Connecting the DC Input Power Terminals to the Terminal Blocks
1 2
207935
1 Negative 2 Positive
Step 6 Use a ratcheting torque Phillips-head screwdriver to torque the terminal-block screw to 14 in-lb.
Caution Do not overtorque the terminal-block screws. The recommended maximum torque is 14 in-lb.
Caution Secure the wires coming from the terminal block so that they cannot be disturbed. For example, use tie
wraps to secure the wires to the rack.
Step 7 After ensuring that all wire connections are secure, reinstall the terminal block cover.
Step 8 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to ON.
Step 9 Move the DC power supply module switch to ON.
Step 10 From the front of the switch, confirm that the PS IN and the PS/FAN LEDs are green. If you can access
the switch rear panel, verify that the power supply module PSU and INPUT LEDs are green. See the
Power Supply Module LEDs section on page 1-11 for a description of the power supply module LEDs.
See the Switch LED Panels section on page 1-7 for system LED descriptions
Caution To prevent overheating and to maintain proper air flow, either a power supply module or a fan module
must be installed in each power supply module slot at all times.
207480
Step 2 Align the two captive screws with the screw holes in the panel. Use a ratcheting torque screwdriver to
torque each screw to 10 in-lb.
Step 3 From the front of the switch, confirm that the PS/FAN LED is green. If you can access the switch rear
panel, verify that the FAN LED is green. See the Fan Module LED section on page 1-13 for a
description of the fan module LED. See the Switch LED Panels section on page 1-7 for system LED
descriptions.
Diagnosing Problems
The LEDs on the front panel provide troubleshooting information about the switch. They show power-on
self-test (POST) failures, port-connectivity problems, and overall switch performance. You can also get
statistics from the CLI or from an SNMP workstation. See the software configuration guide and the
switch command reference on Cisco.com or the documentation that came with your SNMP application
for more information.
Note POST failures are usually serious. Contact your Cisco technical support representative if your switch
does not pass POST.
Switch LEDs
You must have physical access to the switch to do this. Look at the port LEDs for troubleshooting
information about the switch. See the LEDs section on page 1-6 for a description of the LED colors
and their meanings.
Switch Connections
Link Status
Verify that both sides have link. A single broken wire or one shutdown port can cause one side to show
link, but the other side does not have link.
A port LED does not guarantee that the cable is fully functional. The cable might have encountered
physical stress that causes it to function at a marginal level. If the port LED does not turn on:
Connect the cable from the switch to a known good device.
Make sure that both ends of the cable are connected to the correct ports.
Verify that both devices have power.
Verify that you are using the correct cable type. See Appendix B, Connector and Cable
Specifications, for more information.
Look for loose connections. Sometimes a cable appears to be seated, but is not. Disconnect the cable
and then reconnect it.
Switch Performance
Cabling Distance
If the port statistics show excessive FCS, late-collision, or alignment errors, verify that the cable distance
from the switch to the connected device meets the recommended guidelines. See the Cables and
Adapters section on page B-5 for cabling guidelines.
Caution This procedure clears the IP address and all configuration information stored on the switch. Do not
follow this procedure unless you want to completely reconfigure the switch.
Figure 4-1 Serial Number Location on the Cisco ME 3800X and ME 3600X
208326
SN: XXXNNNNXXXX
Environmental Ranges
Operating Environment and Normal Operating Ambient Air Temperature and Altitudes
Altitude1, 2
23 to 122F (5 to 50C), up to 1,000 feet (300 m)
23 to 113F (5 to 45C), up to 6,000 feet (1800 m)
23 to 104F (5 to 40C), up to 10,000 feet (3000 m)
Short-Term3 Exceptional Operating Ambient Air Temperature and
Altitudes
23 to 140F (5 to 60C), up to 1,000 feet (300 m)
23 to 131F (5 to 55C), up to 6,000 feet (1800 m)
23 to 122F (5 to 50C), up to 10,000 feet (3000 m)
23 to 113F (5 to 45C), at sea level with single fan failure
Normal Operating Internal Sensor Temperature
4 to 158F (20 to 70C)
4
Acoustic Noise LpA: 43 dB typical, 46 dB maximum
LwA: 5.4 B typical, 5.6 B maximum
Relative humidity 5 to 95% (noncondensing)5.
Storage temperature 40 to 158F (40 to 70C).
Storage altitude Up to 15,000 ft (4570 m).
1. GLC-T SFP can only be used from 23 to 122F (5 to 50C) up to 1,000 feet (300 m) environment for normal operating
and short-term conditions.
2. The switch supports 5C operation provided that it powers up at ambient temperature equal to or greater than 0C.
SFP-10G-LRM SFP+ module can only be used from 32 to 122F (0 to 50C).
3. Not to exceed more than 96 consecutive hours, 360 total hours, or 15 occurrences in a 1-year period.
4. Acoustic noise is measured per ISO 7779 and declared per ISO 9296.
5. This can be limited by specification of optical modules.
Physical Dimensions
Weight 14.50 lb (6.58 kg) (no FRU installed)
Dimensions (H x W x D) 1.72 x 17.50 x 20.39 in. (4.37 x 44.45 x 51.79 cm)
AC Power Requirements
Input voltage 100 to 240 VAC 10% (autoranging), 50 to 60 Hz.
Power consumption with 1 AC power Total: 779 BTUs per hour (maximum).
supply module and 1 fan module
Maximum: 228 W (worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 155 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 123 W (no cables or SFP modules installed).
Power rating: 120 V (0.254 KVA), 230 V (0.248 KVA).
Power consumption with 2 AC power Total: 796 BTUs per hour (maximum).
supply modules installed
Maximum: 233 W (worst-case SFPs, SFP+ LRM, 100% traffic).
Typical: 163 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 132 W (no cables or SFP modules installed).
Power rating: 120 V (0.259 KVA), 230 V (0.254 KVA).
DC Power Requirements
Input voltage 18 to 32 VDC and 36 to 72 VDC.
Power consumption with 1 DC power Total: 840 BTUs per hour (maximum).
supply module and 1 fan module Maximum: 246 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 156 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100%
traffic).
Minimum: 124 W (48 VDC, no cables or SFP modules installed).
Power consumption with 2 DC power Total: 813 BTUs per hour (maximum).
supply modules installed
Maximum: 238 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% traffic).
Typical: 161 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100%
traffic).
Minimum: 129 W (48 VDC, no cables or SFP modules installed).
Note If you install one AC and one DC power supply module in a switch, the power specifications are similar
to two installed DC power supply modules.
Physical Dimensions
Weight 14.50 lb (6.58 kg) (no FRU installed)
Dimensions (H x W x D) 1.72 x 17.50 x 20.39 in. (4.37 x 44.45 x 51.79 cm)
AC Power Requirements
Input voltage 100 to 240 VAC 10% (autoranging), 50 to 60 Hz.
Power consumption with 1 AC power Total: 762 BTUs per hour (maximum).
supply module and 1 fan module
Maximum: 223 W (worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 155 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 123 W (no cables or SFP modules installed).
Power rating: 120 V (0.248 KVA), 230 V (0.243 KVA).
Power consumption with 2 AC power Total: 778 BTUs per hour (maximum).
supply modules installed
Maximum: 228 W (worst-case SFPs, SFP+ LRM, 100% traffic).
Typical: 163 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 132 W (no cables or SFP modules installed).
Power rating: 120 V (0.254 KVA), 230 V (0.243 KVA).
DC Power Requirements
Input voltage 18 to 32 VDC and 36 to 72 VDC.
Power consumption with 1 DC power Total: 823 BTUs per hour (maximum).
supply module and 1 fan module Maximum: 241 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 156 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100%
traffic).
Minimum: 124 W (48 VDC, no cables or SFP modules installed).
Power consumption with 2 DC power Total: 796 BTUs per hour (maximum).
supply modules installed
Maximum: 233 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% traffic).
Typical: 161 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100%
traffic).
Minimum: 129 W (48 VDC, no cables or SFP modules installed).
Note If you install one AC and one DC power supply module in a switch, the power specifications are similar
to two installed DC power supply modules.
Physical Dimensions
Weight 14.15 lb (6.42 kg) (no FRU installed)
Dimensions (H x W x D) 1.72 x 17.50 x 20.39 in. (4.37 x 44.45 x 51.79 cm)
AC Power Requirements
Input voltage 100 to 240 VAC 10% (autoranging), 50 to 60 Hz.
Power consumption with 1 AC power Total: 656 BTUs per hour (maximum).
supply module and 1 fan module
Maximum: 192 W (worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 150 W (12 SFPs with 1000Base-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 117 W (no cables or SFP modules installed).
Power rating: 120 V (0.214 KVA), 230 V (0.209 KVA).
Power consumption with 2 AC power Total: 677 BTUs per hour (maximum).
supply modules installed
Maximum: 198 W (worst-case SFPs, SFP+ LRM, 100% traffic).
Typical: 158 W (12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100% traffic).
Minimum: 126 W (no cables or SFP modules installed).
Power rating: 120 V (0.220 KVA), 230 V (0.215 KVA).
DC Power Requirements
Input voltage 18 to 32 VDC and 36 to 72 VDC.
Power consumption with 1 DC power Total: 711 BTUs per hour (maximum).
supply module and 1 fan module Maximum: 208 W (18 VDC input, worst-case SFPs, SFP+ LRM, 100% traffic).
installed
Typical: 151 W (48 VDC, 12 SFPs with 1000BASE-SX, 2 SFP+ with SR, 100%
traffic).
Minimum: 117 W (48 VDC, no cables or SFP modules installed).
Power consumption with 2 DC power Total: 697 BTUs per hour (maximum).
supply modules installed
Maximum: 204 W, 18 VDC input (maximum fan speed, all ports linked).
Typical: 157 W (48 VDC, SFP modules installed, 12 ports linked).
Minimum: 124 W (48 VDC, no SFP modules installed).
Note If you install one AC and one DC power supply module in a switch, the power specifications are similar
to two installed DC power supply modules.
Environmental Ranges
Operating temperature 40 to 122F (40 to 50C)
Storage temperature 49 to 185F (45 to 85C)
Relative humidity 5 to 95% (noncondensing)
Altitude Up to 10,000 ft (3049 m)
Physical Specifications
Weight AC: 2.9 lb (1.32 kg)
DC: 3.1 lb (1.41 kg)
Fan: 1.65 lb (0.75 kg)
Dimensions (H x W x D) 1.64 x 8.55 x 5.94 in. (4.16 x 21.72 x 15.09 cm)
Power Specifications
Maximum output power 390 W
Input voltage range and frequency 100 to 240 VAC 10% (autoranging), 50 to 60 Hz
Input current 5 to 2.5 A
Note For AC input, a 5A fuse is recommended.
Maximum output ratings 12 V @ 32.5 A
Total input BTU 1705 BTUs per hour
Power Specifications
Maximum output power 390 W
Input voltage range 18 to 32 VDC and 36 to 72 VDC
Input current 30 A maximum at minimum input 18VDC
15 A maximum at maximum input voltage 72VDC
Note For DC input, a 25A fuse is recommended.
Maximum output ratings 12 V @ 32.5 A
Total input BTU 1840 BTUs per hour
Connector Specifications
10/100/1000, page B-1
SFP and SFP+ Module Connectors, page B-2
10/100/1000 Ethernet Management Port, page B-3
Alarm Input Port, page B-3
BITS Port, page B-4
10/100/1000
The 10/100/1000 Ethernet ports use standard RJ-45 connectors and Ethernet pinouts.
Pin Label 1 2 3 4 5 6 7 8
1 TP0+
2 TP0-
3 TP1+
4 TP2+
5 TP2-
6 TP1-
7 TP3+
60915
8 TP3-
Pin Label 1 2 3 4 5 6 7 8
1 TP0+
2 TP0-
3 TP1+
4 TP2+
5 TP2-
6 TP1-
7 TP3+
60915
8 TP3-
126809
10/100/1000 Ethernet Management Port
The 10/100/1000 Ethernet management port uses standard RJ-45 connectors with Ethernet pinouts.
Pin Label 1 2 3 4 5 6 7 8
1 TP0+
2 TP0-
3 TP1+
4 TP2+
5 TP2-
6 TP1-
7 TP3+
60915
8 TP3-
Note We recommend using a shielded cable grounded at both ends for NEBS.
1 Alarm 1 input
2 Alarm 2 input
3 no connection
4 Alarm 3 input
5 Alarm 4 input
6 no connection
7 no connection
280950
8 Alarm common
BITS Port
Core Modal
Wavelength Size/Cladding Bandwidth
SFP Module (nanometers) Fiber Type Size (micron) (MHz/km)1 Cable Distance
100BASE-BX 1310 TX SMF G.6522 32,810 feet (10 km)
(GLC-FE-100BX-D 1550 RX
GLC-FE-100BX-U)
100BASE-EX 1310 SMF G.6522 131,240 ft (40 km)
100BASE-FX 1310 MMF 50/125 500 6,562 feet (2 km)
(GLC-GE-100FX) 62.5/125 500 6,562 feet (2 km)
100BASE-FX 1310 MMF 50/125 500 6,562 feet (2 km)
(GLC-FE-100FX) 62.5/125 500 6,562 feet (2 km)
100BASE-LX 1310 SMF G.6522 32,810 feet (10 km)
(100BASE-LX10)
100BASE-ZX 1550 SMF G.652 262,480 ft (80 km)
2
1000BASE-BX10-D 1490 TX SMF G.652 32,810 feet (10 km)
(GLC-BX-D) 1310 RX
Core Modal
Wavelength Size/Cladding Bandwidth
SFP Module (nanometers) Fiber Type Size (micron) (MHz/km)1 Cable Distance
DWDM 1560.61, 1559.79, SMF G.6522 62 miles (100 km)
1558.98, 1558.17,
1556.55, 1554.55,
1554.94, 1554.13,
1552.13, 1551.72,
1550.92, 1550.12,
1548.51, 1547.72,
1546.92, 1546.12,
1546.12, 1544.53,
1543.73, 1542.94,
1542.14, 1540.56,
1539.77, 1538.98,
1536.61, 1535.82,
1535.04, 1534.25,
1532.68, 1531.90,
1531.12, 1530.33
10GBASE-LR 1310 SMF G.6522 6.21 miles (10 km)
(SFP-10G-LR)
10GBASE-SR 850 MMF 62.5/125 160 85 feet (26 m)
(SFP-10G-SR) 62.5/125 200 108 feet (33 m)
50/125 400 216 feet (66 m)
50/125 500 269 feet (82 m)
50/125 2000 6,561 feet (2000 m)
10GBASE-CX1
(SFP-H10GB-CU1M) Twinax cable, 30-AW 3 feet (1 m)
cable assembly
(SFP-H10GB-CU3M) Twinax cable, 24-AWG
9 feet (3 m)
cable assembly
(SFP-H10GB-CU5M) Twinax cable, 30-AWG 16 feet (5 m)
cable assembly
1. Modal bandwidth applies only to multimode fiber.
2. A mode-field diameter/cladding diameter = 9 micrometers/125 micrometers.
3. Requires a mode-conditioning patch cord. An ordinary patch cord with MMF, 1000BASE-LX/LH SFP modules, and a short link distance can cause
transceiver saturation, resulting in an elevated bit error rate (BER). When using the LX/LH SFP module with 62.5-micron diameter MMF, you must also
install a mode-conditioning patch cord between the SFP module and the MMF cable on both the sending and receiving ends of the link. Link distances
greater than 984 feet (300 m) require the mode-conditioning patch cord.
4. 1000BASE-ZX SFP modules can send data up to 62 miles (100 km) by using dispersion-shifted SMF or low-attenuation SMF; the distance depends on
the fiber quality, the number of splices, and the connectors.
Note When the fiber-optic cable span is less than 15.43 miles (25 km), you should insert a 5-decibel (dB) or
10-dB inline optical attenuator between the fiber-optic cable plant and the receiving port on the
1000BASE-ZX SFP module at each end of the link.
Cable Pinouts
Figure B-8 Two Twisted-Pair Straight-Through Cable Schematic
Switch Router or PC
3 TD+ 3 RD+
6 TD 6 RD
1 RD+ 1 TD+
H5578
2 RD 2 TD
Switch Switch
3 TD+ 3 TD+
6 TD 6 TD
1 RD+ 1 RD+
H5579
2 RD 2 RD
Figure B-10 Four Twisted-Pair Straight-Through Cable Schematic for 1000BASE-T Ports
Switch Router or PC
1 TP0+ 1 TP0+
2 TP0- 2 TP0-
3 TP1+ 3 TP1+
6 TP1- 6 TP1-
4 TP2+ 4 TP2+
5 TP2- 5 TP2-
7 TP3+ 7 TP3+
65271
8 TP3- 8 TP3-
Figure B-11 Four Twisted-Pair Crossover Cable Schematics for 1000BASE-T Ports
Switch Switch
1 TP0+ 1 TP0+
2 TP0- 2 TP0-
3 TP1+ 3 TP1+
6 TP1- 6 TP1-
4 TP2+ 4 TP2+
5 TP2- 5 TP2-
7 TP3+ 7 TP3+
65274
8 TP3- 8 TP3-
To identify a crossover cable, compare the two modular ends of the cable. Hold the cable ends
side-by-side, with the tab at the back. The wire connected to pin 1 on the left plug should be the same
color as the wire connected to pin 3 on the right plug. The wire connected to pin 2 on the left plug should
be the same color as the wire connected to pin 6 on the right plug.
Pin 1 Pin 3
Pin 2 Pin 6
273807
Table B-3 lists the pinouts for the console port, the RJ-45-to-DB-9 adapter cable, and the console device.
Table B-4 lists the pinouts for the console port, RJ-45-to-DB-25 female DTE adapter, and the console
device.
Note The RJ-45-to-DB-25 female DTE adapter is not supplied with the switch. You can order a kit (part number
ACS-DSBUASYN=) containing this adapter from Cisco.
Switch
Console RJ-45-to-DB-25 Console
Port (DTE) Terminal Adapter Device
Signal DB-25 Pin Signal
RTS 5 CTS
DTR 6 DSR
TxD 3 RxD
GND 7 GND
GND 7 GND
RxD 2 TxD
DSR 20 DTR
CTS 4 RTS
This appendix provides a CLI-based setup procedure for a standalone switch. Before connecting the
switch to a power source, review the safety warnings in Chapter 2, Switch Installation and Chapter 3,
Installing and Removing AC and DC Input Power Supply and Fan Modules.
To power on the switch, connect one end of the AC power cord to the AC power connector on the switch,
and connect the other end of the power cord to an AC power outlet.
To power on a DC switch, see Chapter 3, Installing and Removing AC and DC Input Power Supply and
Fan Modules.
IP Settings
You will need this information from your network administrator before you complete the setup program:
Switch IP address
Subnet mask (IP netmask)
Default gateway (router)
Enable secret password
Enable password
Telnet password
At any point you may enter a question mark '?' for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'.
Step 2 Enter a host name for the switch, and press Return.
On a command switch, the host name is limited to 28 characters; on a member switch to 31 characters.
Do not use -n, where n is a number, as the last character in a host name for any switch.
Enter host name [Switch]: host_name
Step 6 (Optional) Configure Simple Network Management Protocol (SNMP) by responding to the prompts.
You can also configure SNMP later through the CLI. To configure SNMP later, enter no.
Configure SNMP Network Management? [no]: no
Any interface listed with OK? value ''NO'' does not have a valid configuration
Step 7 Enter the interface name (physical interface or VLAN name) of the interface that connects to the
management network, and press Return. For this release, always use vlan1 as that interface.
Enter interface name used to connect to the
management network from the above interface summary: vlan1
Step 8 Configure the interface by entering the switch IP address and subnet mask and pressing Return. The IP
address and subnet masks shown below are examples.
Configuring interface vlan1:
Configure IP on this interface? [yes]: yes
IP address for this interface: 10.4.120.106
Subnet mask for this interface [255.0.0.0]: 255.0.0.0
You have now completed the initial configuration of the switch, and the switch displays its initial
configuration. This is an example of output that appears:
The following configuration command script was created:
hostname switch1
enable secret 5 $1$Ulq8$DlA/OiaEbl90WcBPd9cOn1
enable password enable_password
line vty 0 15
password terminal-password
no snmp-server
!
no ip routing
!
interface Vlan1
no shutdown
ip address 10.4.120.106 255.0.0.0
!
interface GigabitEthernet0/1
!
interface GigabitEthernet0/2
interface GigabitEthernet0/3
!
...<output abbreviated>
end
If you want to save the configuration and use it the next time the switch reboots, save it in NVRAM by
selecting option 2.
After you complete the setup program, the switch can run the default configuration that you created. If
you want to change this configuration or want to perform other management tasks, use the CLI.
To use the CLI, enter commands at the Switch> prompt through the console.