Vous êtes sur la page 1sur 2

Customer Information for Solar PV Tracker

Custome
r Name: MBP SOLAR PVT LTD
Project Site Details with address: At -Lingi, Tal.:- Aurad; Dist.:- Bidar.
Details Global Coordinates (Lat/Long): Lati:- 18.36 Longi:- 77.36
Capacity (AC/DC): 40 MW/45MW
CUF Limit (If any): 21.98
Project Supply Start date: 20/02/17 (Boundary already started )
Timelines Supply End date: 15/03/17 Onwards
Commissioning Date (as per PPA): 31 /08/17
Module Module Rating (Wp):320
Details Manufacturer :Canadian solar
Modules per String:20 Modules in Series,6875 Strings
Design Required Ground Coverage Ratio (GCR):
Details Or Pitch and orientation (Landscape/Portrait):4.2 mtrs Tilt angle 50

Inverter Make & kW rating: ABB (1MW)

Inverter Container Block Size: 3630/2130/708

Simulation Parameters (system losses as available)

Collector plain radiation -


22.6
0
Shadow Loss 2.80
IAM factor on global 0.70
Soiling loss factor 2.00
Due to irradiation level -
0.40
Due to Temperature 9.80
Module Quality 0.00
Module Array Mismatch 1.00
Avg DC Ohmic losses 1.20
Inverter losses 1.50
Transformer losses 1.70
AC Cable loss 0.30
Aux. loss 0.70
Transmission line losses 0.59
LID of module for 1st year 1.50
Degradation of module in 1st year 1.00
except LID
Yearly degradation of module from 0.70
2nd year
Plant downtime 1.00
Scope Tracker Supply + Installation
MMS SUPPLY & Instalation
Site Layout (cad drawing):NA
Documen Soil Test report: NA
ts
Needed Land Contour at 2*2 m grid: Toposheet provided
Module Datasheet :Attached
Module Installation Manual: Attached
DC & AC SLD (if available):Attached