Vous êtes sur la page 1sur 6

VOLVO CONSTRUCTION EQUIPMENT

SERVICE BULLETIN
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 1/6
Applies to models
L110F, L120F, L150F, L180F, L180F HL, L220F, L350F, L60F, L70F, L90F
Supersedes SB 366WLO219K dated 2014-10-02. Changes are marked with lines in the margin.
ONLY FOR DISTRIBUTORS / DEALERS

New software release V2015.2.0


NOTE!
Please pay attention to the safety instructions in the Operator's
and Service Manuals concerned.
This Service Bulletin is to be considered as technical information
only and is not subject to any reimbursement programs outside
normal warranty.

Cause and action


Turbo hot shut down, same functionality as on WLO G-
models, is introduced. The engine is considered hot if the
engine torque has been high for 60 seconds during the past
180 seconds. If the temperature is considered to be too high;
maximum hot engine waiting time will be 120 seconds.
New functionality is added on the electro servo lever.
Automatic tilt, lift, return-to-dig and float position are affected.
It is now possible to use the lever with disabled detent solenoid
function; same functionality as on WLO G-models. The main
control of automatic functions, activation / deactivation and
setting position, is set by the switches on the cab post panel.
The automatic function is activated the same way as before;
by pushing or pulling the lever to the end position. At any
automatic function, the lever will move back to neutral position
after activation.

Volvo Construction Equipment


Feedback mail: sb@volvo.com
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 2/6

The deactivation sequence of automatic functions has been


changed. The automatic function is aborted as soon as the
operator moves the lever in any direction from neutral position.
Example: Automatic lift activation is done by moving the lever to
the end lift position and then the lever is back to neutral. The boom
will raise to its presetting. If the lever is pushed forward during the
lift operation, the function will be aborted and the lifting frame
stops at its position.
The new functionality can be chosen by a parameter QHX-setting
by TechTool. Parameter QHX (V2ECU) defines which electric
lever type that is being used:
0 = lever with detent solenoid function
1= lever with disabled detent solenoid function
2= electric single lever (not used in WLO F-models)
NOTE!
The default setting on the parameter in this software is type 1. If
the operator wants to use the original setting with detent magnet
in the lever, the setting on parameter QHX should be changed to
type 0.
Current I-ECU communication; when the machine was not
used for a longer period of time, the super cap batteries in the
I-ECU were discharged and created cranking problems. The
reason may have been that no Date and Time was set in the I-
ECU because the super cap batteries in the I-ECU needed to
be charged.
In this new software, a guard has been added that actively will
check Date and Time and automatically set corrections to
prevent cranking issues.
Hardware / software part number for W-ECU (MID142) is
added in the menu / display.
Boom suspension system (BSS) can now deactivate also in F1
and R1 gear.
Axle oil temperature sensor; corrections introduced to reduce
the risk of false alarms.
Reversible fan error code MID187 PSID 67 FMI 5 and MID187
PSID35 FMI5; corrections of the extended diagnostic for
reversible fan control.
Changed speed dependent activation for Return-to-dig and
Float to 20 km/h.
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 3/6

Select available software campaigns according to tables


below:
NOTE!
After software update, we recommend to perform calibration of
the electro servo boom and tilt system.
Alternative A: V2015.2.0*SB366WLO384K*A for use in Pre-
SIL machines without electric servo boom and tilt function
Alternative A2: V2015.2.0*SB366WLO384K*A2 for use in Pre-
SIL machines with new angle sensor installation for electric
servo boom and tilt function

Model Serial No. Serial No. Serial No.


ARV ASH PED
L60F 4001 5448 61401 61928 70601 71062
L70F 24001 25342 61801 62570 71401 71693
L90F 25001 26953 68101 68916 71501 71705
L110F 3501 4391 61501 61878 70601 70660
L120F 23001 24924 66401 66728 71701 71899
L150F 13001 14651 N/A N/A
L180F 11001 12383 N/A N/A
L220F 6001 6929 N/A N/A
L350F 1001 1249 N/A N/A

Alternative B: V2015.2.0*SB366WLO384K*B for use in Pre-


SIL machines without electric servo boom and tilt function
Alternative B2: V2015.2.0*SB366WLO384K*B2 for use in Pre-
SIL machines with new angle sensor installation for electric
servo boom and tilt function

Model Serial No. Serial No. Serial No.


ARV ASH PED
L60F 5449 7130 61929 62018 71063 72893
L70F 25343 26959 62571 62668 71694 72287
L90F 26954 29441 68917 69044 71706 72544
L110F 4392 5615 61879 61939 70661 71008
L120F 24925 27377 66729 66769 71900 72728
L150F 14652 17724 N/A N/A
L180F 12384 15577 N/A N/A
L220F 6930 8485 N/A N/A
L350F 1250 1756 N/A N/A
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 4/6

Work instruction TechTool


1 Start TechTool and log in online (Connect to Central
Systems).
2 Select [TechTool] - Manage Software.
3 Type in chassis ID, MID and campaign.
4 Press [Add].
5 Check which ECU's are in the machine.
6 Delete unwanted/non existing ecus N.B. It is only possible
to download one MID/type per machine.
7 Press [Send order].
8 Make sure the software is downloaded by checking
[Available software].
9 Close [Administrate software] tab.
10 Close TechTool or continue to item 12 if you already are in
the machine.
11 Start TechTool.
12 Connect TechTool to machine, the machine will be selected
automatically.
13 Enter work order number.
14 Select [Program].
15 Start operation "17093-3 Program with stored software".
16 Follow the steps in the operation.
17 Error codes can occur, for no obvious reason, during
calibration, adjustment of parameters or software
programming. All error codes should be deleted with
TechTool before leaving the machine.
The available TechTool campaign name for this software release
is:
V2015.2.0*SB366WLO384K
In case of software programming problems, contact:
vce.softwaresupport@volvo.com
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 5/6

Fig.1
Language Code Group Product No. Version Date Page
GB 366 WLO 384 K 2 2015-10-22 6/6

Fig.2