FORM U-DR-1 USERS DESIGN REQUIREMENTS FOR SINGLE CHAMBER PRESSURE VESSELS

Country of Installation: State/Province of City of Installation:


Owner: Ferrofab FZE Operator: KOC, Kuwait
Kuwait Installation:
Process Gas Liquid Level: Full UN01-E-804A/B
Service: Item No.:
Specific Gravity: 1.0

Diameter (in.): NPS 6 Length, Tangent-to-Tangent: 2286 (Seam to Type:


Seam) Vertical Horizontal Sphere
National Board Canadian Special Service: Overpressure Protection:
Registration Required: Registration Required: Lethal (L) Direct Firing (DF) Valve Rupture Disk
Yes No Yes No Unfired Steam Boiler (UB) Other System Design
OPERATING CONDITIONS: Minimum Pressure Maximum Pressure Minimum Temperature Maximum Temperature

Case 1 7.48 barg 7.58 barg 10.9385 C 30 C


Case 2 -- -- -- --
DESIGN CONDITIONS: Pressure Temperature
Internal Design Pressure: 16.2 bar g 93.3 C
External Design Pressure: FV 93.3 C
MAWP Internal: bar g Same as Design Pressure Calculated by Manufacturer:
MAWP External: bar g Same as Design Pressure Calculated by Manufacturer:
Minimum Design Metal Temperature Deg @ Due to: Process Other
-29 C 16.2 bar g Ambient Temperature
(MDMT) Case 1
Minimum Design Metal Temperature Deg @ Due to: Process Other
(MDMT) Case 2 Ambient Temperature
Corrosion Allowance: Shell Heads Nozzles Jacket Coil Supports Internals Corrosive
No Service?
Int. Ext. Int. Ext. Int. Ext. Int. Ext. Int. Ext. Int. Ext. Yes No
Yes -- -- -- -- -- -- -- -- -- -- -- -- --
Cyclic Service: Yes No NA Cycles per Design Life NA years Fatigue Analysis? Yes No
Wind Loading: ASCE 7 Wind Speed Classification Exposure Topographic Elevation
UBC IBC Category Category Factor
Other None 162 km/hr -- -- -- --
Seismic Loading: ASCE 7 Soil Profile Classification: PWHT: Other Loadings per UG-22:
UBC IBC Per Code Temp. Gradients Deflagration
Site D
Other None Process Required Diff. Thermal Exp.
Insulated: Yes No Type Thickness Density Coating Specification NA
External Yes 50 --
By Manufacturer By Others
Internal -- -- Permitted Prior to Pressure Test
Yes No
Vessel Support: Legs Skirt Lugs Saddles Fireproofing: Type: -- Rating (hr): --
Yes No
MATERIALS
Component Specification Component Specification
Shell SA 312M TP 316L Ellipsoidal Head --
Hemispherical Head -- Torispherical Head --
Toriconical Head -- Conical Head --
Nozzles SA 312M TP 316L Flanges SA-182 F316L
Stiffener Rings -- Pressure Retaining Bolts SA 193 Gr. B8M / SA 194 Gr. 8M
Attachments SA 240 316L Internals SS316L
Reinforcing Pads SA 240 316L Other --

NOZZLE SCHEDULE
Description Number Size Flange Class Description Number Size Flange Class
Required Type Required Type
Nozzle A 1 6" WNRF 300
Nozzle B 1 2 WNRF 300

07/10

PRINT SAVE
FORM U-DR-1 (Back)

WELDED PRESSURE JOINT REQUIREMENTS


DESIGN BASIS: SHELL AND CONE THICKNESS BASED ON: HEAD THICKNESS BASED ON:
Design by Rule JOINT EFFICIENCY E = 1.00 JOINT EFFICIENCY E = 1.00

JOINT LOCATION TYPE OF JOINT NDE WITH COMMENTS


UW-3 (Use Types as Described in UW-12)

Category A -- --

Category B Head-to-Shell -- --

Other -- --

Category C Body Flanges -- --

Nozzle Flanges -- --

Category D -- --

BODY FLANGE REQUIREMENTS


Description Type Facing/Surface Finish Gasket Style Joint Assembly
(See ASME PCC-1)
EIH Flange Blind RF / 125 to 250 AARH SPWD Bolted

SKETCH

GENERAL NOTES
1.0 All dimensions are in 'mm' Unless otherwise stated.
2.0 Hydrotest pressure to test Bundle is 53.8 bar g (54.8 kg/cm g).

CERTIFICATION
We certify that the statements made in this form are accurate and represent all details of design as per the user or his designated agent
[see U-2(a), Footnote 4]

Date: 11/05/2016

M/s. Ferrofab Fze


User:

Signed:
(Representative)

Registration Identification:
(Optional)
Registration Seal (Optional)
03/08
Above filled data is in line with Ferrofab FZE Drawing "
PRINT Dwg. No.: FF-2109-PV-DWG-05-001, Rev 00" SAVE