Vous êtes sur la page 1sur 16

HIGH POWER

SCP Super Compact


Edizione 11/2007
Edizione 04/2008

ZHP07V/GB
Busbar Trunking SCP
The simple and innovative choice
The connection between For thes
the transformer and as well
the main switchboard a solutio
and between the main size of t
switchboard and the and to s
secondary switchboards the SCP
creates the backbone of
the electrical installation.

TRANSFORMERS

2 SCP SUPER COMPACT


For these applications, power distribution
as well as rising mains, Zucchini offers
a solution designed to reduce the SAFETY
size of the installation to a minimum The best
and to simplify the connection: protection for
the SCP Super Compact range. your installation

FLEXIBILITY
The optimum
solution for evolving
installations
SIMPLICITY
The professional
solution for
everyone

GENERAL CHARATERISTICS 3
SCP SUPER COMPACT
SIMPLICITY
A Solution for everyone
SIMPLICITY AND SPEED OF INSTALLATION SIMP
The SCP range has been designed to The c
simplify the installation, and therefore syste
making it safe and fast to install. the de
To correctly evaluate the installation
time, it is necessary to take into Tradit
consideration all the operations for ca
required (tab.1), which, sometimes, are exam
overlooked when comparing a traditional by the
cable solution to a Busbar solution. can a
therm
reacta
- To carry out medium and high power distribution, it
positi
is necessary to install several cables in parallel for to eac
each phase:
- To ensure equal distribution of the current through A Bus
the cables, three criteria must be satisfied: all the not re
cables must be of the same type, the cables have to be
to be of the same length and of the same layout.
Also, during the laying of a group of cables, it is
comp
necessary to maintain a solid anchorage in order comp
to contain the electrodynamic forces which can be is test
generated during a possible short circuit. the m
The p
not in
fixing
affect
chara
circuit

Tab 1

Suspensio
Cable tray
Busbar in
Cable cut
Cable pul
Cable end
Cable con
Cable tray

4 SCP SUPER COMPACT


SIMPLICITY OF DESIGN
The concept of a Busbar trunking
system gives a simplification of
the design process.

Traditionally, the design layout


for cable is more complicated: for
example, the rating is influenced
by the type of grouping, which
can alter the efficiency of the
thermal dissipation, while the
reactance is influenced by the
position of the cables in respect
to each other.

A Busbar trunking system does


not require all these considerations
to be taken into account as it
comprises prefabricated
components, whose performance
is tested and stated by
the manufacturer.
The performance of the Busbar is
not influenced by the types of
fixings and layout which can
affect the rating, the electrical
characteristics and the short
circuit withstand of the cables.

Tab 1 Busbar installation Cable installation


Suspension bracket installation s s
complete
Cable tray installation no s
installation
Busbar installation s no
Cable cutting no s
Cable pulling/laying (one at a time) no s
Cable end preparation (cable lugs) no s
Cable connection no s complete
installation
Cable tray closing no s

GENERAL CHARATERISTICS 5
SCP SUPER COMPACT
SAFETY
The best protection for your installation
FIRE RESISTANCE
In installations where there
is a high risk of fire (high
number of people or presence
of large quantities of
combustible material and/or
expensive equipment), the
SCP Busbar trunking system
solution gives technical and
economical advantages.
Because of the very low fire
load of the Busbar compared
to cables of equivalent rating,
the safety of the building is
much improved.
SCP has been fire resistance
tested in accordance with
the DIN4102-09 standard.

ELECT
When
distrib
the pr
sensit
MECHANICAL INTERLOCK
syste
The connections between the
becau
elements of the SCP range are keyed
of ele
which ensures installation in the
comp
correct position. Thus mistakes are
cables
avoided which sometimes happen by
(The f
the use of traditional cable solutions
casing
and cause delay or mistakes in the
the ba
installation.
electr
The outer head of the connection block
The m
bolt snaps off when tightened to the
at 1 m
correct nominal torque.
much
This ensures the optimal contact
repres
pressure and consequently the electrical
of sev
continuity. The correct installation is
also confirmed by a visual signal.
OK
6 SCP SUPER COMPACT
> 3 T

ELECTROMAGNETIC EMISSION
When the current has to be
distributed in installations with
the presence of people and/or
> 3 T
sensitive equipment, the Busbar
system is by far the best choice
because of the much lower level
keyed
of electromagnetic emissions
he
compared to those produced by
are
cables of equivalent rating.
n by
(The ferromagnetic structure of the
ons
casing and the compactness of
he
the bars significantly reduce the
electromagnetic field).
n block IP55
The magnetic induction measured
the The degree of protection IP55
at 1 metre from the SCP Busbar is
much lower than 3T which prevents dust accumulation inside the
represents the quality objective Busbar and also ensures total safety
ectrical against direct contact. If a short part
of several countries.
n is of the Busbar run must transit outside
between buildings, it is necessary to
use a metal canopy for protection.

GENERAL CHARATERISTICS 7
SCP SUPER COMPACT
FLEXIBILITY
The optimum solution for different applications
RISING MAINS INSTALLATION HIGH
The SCP range provides all the Each c
necessary components needed for insula
the installation of rising mains. (thick
This is an excellent solution for all sand
high-rise buildings; residential or casing
commercial towers, hospitals and trunk
office towers which have power
distribution on every floor.

There
instal
cable
of lac
This is
espec
angle
to see
than t
soluti
the ca
makin
a grea
With a
reduc
of sta
elbow

8 SCP SUPER COMPACT


ions
HIGH PERFORMANCE IN NARROW SPACES
Each conductor bar of the SCP range is
insulated by a double polyester sheet
(thickness 0,20mm) and assembled in a
sandwich configuration inside the steel
casing. Thus creating a compact Busbar
trunking system.

Therefore the SCP range can be


installed even in places where
cables cannot be installed because
of lack of space.
SCP
This is evident when changing direction,
especially 90. When considering an
angle with a cable solution, it is easy
to see that the space required is larger
than the one required for a busbar
solution. The bundling and the size of
the cables prevent the cables from
making sharp turns, and they require
a greater radius to turn through 90.
With a busbar solution it is possible to
reduce the space required by the use
of standard horizontal or vertical
elbow elements.
Cables

GENERAL CHARATERISTICS 9
SCP SUPER COMPACT
SCP offer

1
A QUALITY PRODUCT
SCP is available in 2 versions: SCP AL 630 A 4000 A
aluminium conductors from 630A to SCP CU 800 A 5000 A
4000A and copper conductors from
800A to 5000A.
VERSIONS
The SCP range is has a high rigidity
and mechanical strength and is almost
SCP 3L+N+PE
40% lighter than a cable solution of SCP5 3L+N+PE+FE (functional/clean earth)
the same rating. Therefore there are SCP2N 3L+N200%+PE
fewer suspension points which means
material, manpower and cost reduction. Ue -1000 V
The compact dimensions of SCP
improve the short circuit withstand,
reduce the impedance of the electrical
installation, limit the voltage drop CONN
and enables high power installations SIMP
even in narrow spaces. SCP provides Tighte
a wide range of tap-off units, from 63A shear
to 1250A, which allows the supply and the o
the protection of the loads, by protection and c
devices such as moulded case circuit
breakers and switch-fuses.

SAFETY 4
The best
protection for
your installation

FLEXIBILITY
The optimum solution
for evolving
installations

SIMPLICITY
The professional
solution for everyone

10 SCP SUPER COMPACT


1

earth)

CONNECTION OF THE INSTALLATION


SIMPLE AND SAFE
Tighten the bolt until the outer head
shears (~85Nm), in order to ensure
the optimum electrical continuity
and correct installation.

TY 4
est
n for
lation

CRACK

OK CERTIFICATION
The SCP range is provided with product
certification and conforms to the main
MPLICITY international standards.
professional The performance of the Busbar
n for everyone
is verified and stated by the
manufacturer regardless of the
layout of the installation, whereas
the performance of cables is influenced
by the type of fixing and installation.

GENERAL CHARATERISTICS 11
SCP SUPER COMPACT
SCP Service
The satisfaction of an efficient service
THE SATISFACTION OF AN
EFFICIENT SERVICE
Zucchini offers the customer not only
products characterized by quality, but also
all the experience gained during over
50 years of Busbar production.

ESTIMATING, PLANNING AND SUPPORT OF THE INSTALLATION

The objective of the company is to The Engineering Design Office develops


give the maximum satisfaction to the in detail customised solutions according
customer, who Zucchini supports from to each specific requirement of the
the very initial stages of the project. customer. This ensures a high level of
service which allows Zucchini to delivery
constant and continuous technical
support, both during the estimating
stage as well as during the
development of the project.
Therefore a profitable and lasting
relationship is established between
Zucchini and the customer.

12 SCP SUPER COMPACT


elops Zucchini provides without charge,
cording if required:
he
el of - The mechanical layout of the
elivery project
al - Study of the connections between
ting TRANSFORMERS
the Busbar and the transformer or
between switchboard enclosures
- Suggestions for the type of fixing
(floor, wall, ceiling)
n - Possibility of site measurement by
skilled people
- Telephone assistance during the
entire installation stage by the
Engineering Design Office.

GENERAL CHARATERISTICS 13
SCP SUPER COMPACT
Suggestions for the project development

EXAMPLE FOR QUOTATION CHECKL


CHECK LIST: PROJECT
1. Verify
1. Rating draw
2500
..A equip
switc
2. Application: 2. Check
Feeder requi
Distribution n of outlets .............. board

3. Icc at the beginning of the line ...............kA


Examp

4. Material:
Aluminium
Copper

5. Degree of protection:
IP55 (standard)

6. Painting:
RAL7035 (standard)

Different RAL
colour on request ...

7. Neutral section:
100% SCP (standard)
200% SCP2N

8. Nominal ambient
temperature:
40C (standard) Zucchini
Other on request . if requir
- The m
proje
9. Attach Busbar layout *
- Study
Drawing the B
File dwg betw
- Sugg
(floo
* Example of drawing to be attached - Pos
skil
- Tele
ent
Eng

14 SCP SUPER COMPACT


CHECKLIST TO BE DONE DURING THE 3. Check for the existence of unforeseen
PROJECT obstacles in the installation which
1. Verify the measurements of the could impede the run of the Busbar
drawings, the correct position of the (for example pipelines, ventilation and
equipment (voltage transformer and LV air-conditioning ducts).
switchboard enclosures 4. Agree upon who is responsible for
2. Check the availability of drawings providing the connection from the
required (transformer, switchboard Busbar to the other devices (voltage
board, etc.) transformer and LV switchboards).

Example of detail of the project

harge,
i p ro v id e s without c
Zucchin
:
if required of the
h e m e c h anical layout
- T
project tween
f th e co n nections be
- Study o er or
a r a n d the transform
the Bu sb nclosures
e n sw itchboard e
be tw e of fixing
g ge st io n s for the type
- Su
ceiling)
(floor, wall, measureme
nt by
il ity o f site
- Possib
le
skilled peop ring the
p h o n e a ssistance du
- Te le y the
re in sta ll ation stage b
enti ce.
Design Offi
Engineering
GENERAL CHARATERISTICS 15
SCP SUPER COMPACT
Zucchini SpA
Via Conicchio, 34
25136 Brescia - Italia
Tel. +39 030 2017.100
Fax +39 030 2009726
info@zucchinispa.it
www.zucchinispa.it

Edizione 11/2007
Edizione 04/2008

Zucchini S.p.A. reserves the rights to change the contents of this brochure at any time and to inform you,
in any form and terms, about the changes made.

Vous aimerez peut-être aussi