PCM KOS PERUNDING SDN BHD BILL NO. 3.

1 - WORK BELOW LOWEST FLOOR FINISH


Description Unit Qty Rate Amount
BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH

WORK BELOW LOWEST FLOOR FINISH

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Excavation

Excavate oversite commencing from formation level, get


out, part return, fill in and ram, deposit, spread, well
compacted to form sub-grade and level remove surplus
excavated materials as described to Contractor's own dump
site

A Oversite excavation; not exceeding 1.0m deep M3 8

Excavate commencing from formation level get out, part


return, fill in and ram, deposit, spread and level remove
surplus excavated materials as described to Contractor's
own dump

B Excavate for thickening; not exceeding 0.25m deep M3 1

Hardcore and the like as described; levelled; well


consolidated; watered and blinded with sand;-

C 150mm thick to receive raft foundation/ ground slab M2 10

D Ditto to receive apron slab M2 9

Lean concrete Grade 15 as described in

E 50mm thick under raft foundation/ ground slab M2 10

F Ditto under apron slab M2 9

Vibrated reinforced concrete Grade 40 as described in

G Ground slab; 150mm - 300mm thick M3 3

H Apron slab; 100mm - 150mm thick M3 1

J Thickening; 150mm - 300mm thick M3 1

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 1/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH
Description Unit Qty Rate Amount
BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH (Cont'd)

WORK BELOW LOWEST FLOOR FINISH (Cont'd)

Mild steel plain round rod reinforcement to B.S. 4449 as


described in

Thickening

A 10mm Diameter as links KG 33

High tensile rod reinforcement to B.S. 4449 as described in

Raft Slab/ Thickening

B 10mm Diameter rod KG 184

Apron Slab

C 10mm Diameter rod KG 239

Sawn formwork as described to :-

D Sides of raft slab; exceeding 250mm but not exceeding


500mm high M 13

E Sides of apron slab; not exceeding 250mm high M 19

F Sides of thickening; exceeding 250mm but not exceeding


500mm high M 9

Sundries

Supply and lay polivinyl chloride (P.V.C) sheet


waterproofing with approved adhesive glue laid on lean
concrete to receive ground slab, lapped 230mm at joints as
described laid strictly in accordance with the manufacturer's
instructions (measured nett-no allowance made for laps)

G 0.200mm Thick PVC to receive ground floor slab M2 10

H Ditto to receive apron slab M2 9

Prepare and apply approved anti-termite treatment as


specified with a five (5) years guarantee and apply strictly
in accordance with the manufacturer's instructions:-

J To whole Sub-structure surfaces contact with soil M2 19

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 1/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH
Description Unit Qty Rate Amount
BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH (Cont'd)

COLLECTION

Page No. 1/1

Page No. 1/2

BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 1/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.2 - FRAME
Description Unit Qty Rate Amount
BILL NO. 3.2 - FRAME

FRAME

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

The quantity for roof beam is measured under the element


of Roof Construction

Concrete Works

Vibrated reinforced in-situ concrete Grade 30 as described in

A Columns M3 0.3

B Suspended Beam M3 0.5

Mild steel plain round rod reinforcement to B.S. 4449 as


described in

Columns

C 8mm Diameter as links KG 42

Suspended Beam

D 6mm Diameter as links KG 13

High tensile rod reinforcement to B.S. 4449 as described in

Columns

E 12mm Diameter rod KG 109

Suspended Beam

F 12mm Diameter rod KG 59

Sawn formwork as described to

G Sides of columns M2 10

H Sides and soffit of suspended beam M2 8

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 2/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.2 - FRAME
Description Unit Qty Rate Amount
BILL NO. 3.2 - FRAME (Cont'd)

COLLECTION

Page No. 2/1

BILL NO. 3.2 - FRAME

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 2/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.3 - UPPER FLOOR
Description Unit Qty Rate Amount
BILL NO. 3.3 - UPPER FLOOR

UPPPER FLOOR

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Concrete Works

Vibrated reinforced concrete Grade 30 as described in

A Counter bench; 100mm thick M3 0.2

B Water tank slabs; 125mm thick M3 0.2

High tensile rod reinforcement to B.S. 4449 as described in

Counter Bench

C 8mm Diameter KG 17

Fabric Reinforcement

Steel fabric reinforcement as described; cut to size; M.S.


145/B.S. 4483:1973; well lapped at joints; including bending
fabrics and notching around obstructions (measured nett - no
allowance made for laps) :-

D BRC No. A7 in water tank slab M2 5

Sawn formwork as described to

E Soffit of counter bench M2 2

F Ditto of water tank slabs M2 2

G To edges of counter bench; not exceeding 250mm high M 6

H To edges of water tank slabs; ditto M 6

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 3/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.3 - UPPER FLOOR
Description Unit Qty Rate Amount
BILL NO. 3.3 - UPPER FLOOR (Cont'd)

COLLECTION

Page No. 3/1

BILL NO. 3.3 - UPPER FLOOR

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 3/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.4 - ROOF
Description Unit Qty Rate Amount
BILL NO. 3.4 - ROOF

ROOF

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

ROOF CONSTRUCTION

Concrete Works

Vibrated reinforced concrete Grade 30 as described in:

A Roof beam M3 0.5

Mild steel plain round rod reinforcement to B.S. 4449 as


described in

Roof Beam

B 6mm Diameter as links KG 13

High tensile rod reinforcement to B.S. 4449 as described in

Roof Beam

C 12mm Diameter rod KG 39

D 16mm Diameter rod KG 24

Sawn formwork as described to:

E To sides and soffit of roof beam exceeding 3.50m but not


exceeeding 5.00m high M2 9

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 4/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.4 - ROOF
Description Unit Qty Rate Amount
BILL NO. 3.4 - ROOF (Cont'd)

ROOF (Cont'd)

ROOF CONSTRUCTION (Cont'd)

Structural Steel Roof

The roof trusses components are following Engineer's detail


drawing no. JJK12004/T/ST/PF/GH/KP/01

The following in structural steelwork members of BS 4360;


all welded and fabricated together and including unloading,
getting in, hoisting, fixing operation, cutting angles lates,
stiffeners, drilling in concrete and steel, shop and site
welding, bolting, painting and all necessary fixing
accessories and incidental works; hoisting and fixing in
position.

A C20020 x 6.01kg/m lipped channel 'C' purlin KG 118

B C10016 x 2.77kg/m lipped channel 'C' purlin KG 47

C 75mm x 75mm x 6mm x 6.85kg/m mild steel equal angle


cleat complete with 2 nos of M12 Grade G4.6 bolts NO 28

D 125mm x 75mm x 6.5mm x 9.98kg/m mild steel unequal


angle cleat complete with 2 nos of M12 Grade G4.6 bolts NO 12

E 12mm diameter sag rod M 6

Timber Roof Truss (at counter bench)

The roof trusses components are following Architect's


detail drawing no. SGM/12-002/ATP/TD/GH/RD/6900

The following timber roof trussess overall span 2.40m x


1.30m all in sawn pressure treated Group 'B' timber or any
other equivalent; fixed together including hoisting and
fixing in position; all in accordance with Architect's
approval and satisfaction

F 50mm x 100mm HW Timber Rafter M 12

G 50mm x 50mm x HW Timber Batten M 8

H 100mm x 50mm x HW frame with expanded bolts and nuts


with washer to support timber truss and fix to brickwall NO 8

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 4/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.4 - ROOF
Description Unit Qty Rate Amount
BILL NO. 3.4 - ROOF (Cont'd)

ROOF (Cont'd)

ROOF FINISHES

Roof Covering

Approved kliplock metal roof covering at 12 degree pitch;


in one continuos lengths of sheet from ridge to eave with no
end laps and fixed to steel structures (measured separately)
with non-corrosive roof connectors including capping to
edges or corners as per manufacturer's recommendation; all
laid strictly in accordance with manufacturer's instruction
(measured nett - no allowance for laps)

A To Main Roof; generally M2 20

B To Counter Bench Roof; generally M2 5

Approved single sided woven aluminium foil; well lapped


at joints; laid over rafters; all in accordance with the
manufacturer's instructions and recommendations and to the
approval of the Architect (measured nett - no allowance
made for laps) -

C To roof generally M2 20

Approved 50mm thick rockwool insulation with a density of


40kg/m3 as described, laid over aluminium foil (measured
separately); all in accordance with the manufacturer's
instructions and recommendations and to the approval of the
Architect (measured nett - no allowance made for laps)

D Generally; to receive metal roofing deck M2 20

22 Gauge Galvanised Iron Flashing

E Approved GI flashing; one edge tucked to brickwall and the


other edge dressed over roofing sheets; including pointing
with approved bituminous sealant to watertightness M 4

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 4/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.4 - ROOF
Description Unit Qty Rate Amount
BILL NO. 3.4 - ROOF (Cont'd)

COLLECTION

Page No. 4/1

Page No. 4/2

Page No. 4/3

BILL NO. 3.4 - ROOF

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 4/4
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.5 - EXTERNAL WALLS
Description Unit Qty Rate Amount
BILL NO. 3.5 - EXTERNAL WALLS

EXTERNAL WALLS

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Brickwork And Blockwork

Common brickwork cement and sand bricks in cement


mortar (1:3) with an approved plasticiser as described in
walls reinforced with and including "Exmet" or other equal
and approved brick reinforcement at every fourth course,
well lapped;

A Half brick (115mm thick) M2 24

Bituminous felt damp-proofed courses as described; to BS


743; well lapped at joints on and including 19mm thick bed
of cement and sand (1:3) mortar coated with hot bitumen
(measured nett - no allowance made for laps)

B Half brick (115mm thick) M 11

Sundries

C 6mm Diameter mild steel bonding ties 450mm long with one end
hooked and cast in concrete and the other end built into
joint of brickwork including perforation holes in formwork ITEM

D Approved corner lath fixed to all angle corner of walls that


with cement plaster finished ITEM

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 5/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.5 - EXTERNAL WALLS
Description Unit Qty Rate Amount
BILL NO. 3.5 - EXTERNAL WALLS (Cont'd)

COLLECTION

Page No. 5/1

BILL NO. 3.5 - EXTERNAL WALLS

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 5/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.6 - INTERNAL WALLS
Description Unit Qty Rate Amount
BILL NO. 3.6 - INTERNAL WALLS

INTERNAL WALLS

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Brickwork And Blockwork

Common brickwork cement and sand bricks in cement


mortar (1:6) with an approved plasticiser as described in
walls reinforced with and including "Exmet" or other equal
and approved brick reinforcement at every fourth course,
well lapped;

A Half brick (115mm thick) M2 7

Bituminous felt damp-proofed courses as described; to BS


743; well lapped at joints on and including 19mm thick bed
of cement and sand (1:3) mortar coated with hot bitumen
(measured nett - no allowance made for laps)

B Half brick (115mm thick) M 4

Sundries

C 6mm Diameter mild steel bonding ties 450mm long with one end
hooked and cast in concrete and the other end built into
joint of brickwork including perforation holes in formwork ITEM

D Approved corner lath fixed to all angle corner of walls that


with cement plaster finished ITEM

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 6/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.6 - INTERNAL WALLS
Description Unit Qty Rate Amount
BILL NO. 3.6 - INTERNAL WALLS (Cont'd)

COLLECTION

Page No. 6/1

BILL NO. 3.6 - INTERNAL WALLS

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 6/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.7 - DOORS
Description Unit Qty Rate Amount
BILL NO. 3.7 - DOORS

DOORS

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Concrete Works

Concrete Grade 30 as described; including all moulds,


hoisting, fixing in position and setting in cement & sand
(1:3) mortar :-

Lintol; with 4 nos. 12mm diameter high tensile


reinforcement bars and 6mm diameter mild steel
reinforcement bars as stirrups at 150mm centres:

A Lintol size 125mm x 200mm High M 2

Metal Door Frame

Supply and fix approved metal door frame 150mm x 50mm


x 1mm thick zincalume single rebated comprising of all
necessary fixing works all in accordance to manufacturer's
detail and as per approved by the Architect

B Door frame to suit door opening Type D90A overall size


900mm x 2100mm high NO 1

C Ditto; Type D75B overall size 750mm x 2100mm high NO 1

Timber Flush Doors

Supply and fix the following timber flush panels


comprising 38mm thick constructed of hardwood timber
stiles, top, intermediate and bottom rails and covered
bothsides with plywood and covered all around with timber
lipping piece; all to Architect's approval :

D Single leaf door Type D90A; overall size 900mm x 2100mm high NO 1

E Single leaf door Type D75B; overall size 750mm x


2100mm high; with waterproofed finishes NO 1

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 7/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.7 - DOORS
Description Unit Qty Rate Amount
BILL NO. 3.7 - DOORS (Cont'd)

DOORS (Cont'd)

Painting

Prepare and apply approved one coat of metal primer,


approved one coat of undercoat and approved two coats
gloss enamel paint in accordance with the manufacturer's
specifications and instructions

A To metal frame; exceeding 200mm but not exceeding


300mm girth M 10

Knot, prime and stop with approved one coat undercoat and
approved two coats gloss enamel paint in accordance with
the mafacturer's specifications and instructions

B General surfaces of timber flush door (measured flat both


sides) M2 7

Ironmongeries

Supply and fix "St Guchi' or other approved equivalent


ironmongery to hardwood, metal works or glass including
providing all requisite matching screws all as described or
approved equivalent:

C Approved 4' x 3' x 2.0mm Stainless steel hinge (H1) NO 6

D Approved cylindrical knobset complete with lock (N2) NO 2

E Approved door stopper (A3) NO 1

F Approved stainless steel magnetic door stopper (A4) NO 1

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 7/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.7 - DOORS
Description Unit Qty Rate Amount
BILL NO. 3.7 - DOORS (Cont'd)

COLLECTION

Page No. 7/1

Page No. 7/2

BILL NO. 3.7 - DOORS

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 7/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.8 - WINDOWS
Description Unit Qty Rate Amount
BILL NO. 3.8 - WINDOWS

WINDOWS

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved " where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Concrete works

Concrete Grade 30 as described; including all moulds,


hoisting, fixing in position and setting in cement & sand
(1:3) mortar :-

Lintol; with 4 nos. 12mm diameter high tensile


reinforcement bars and 6mm diameter mild steel
reinforcement bars as stirrups at 150mm centres:

A Lintol size 125mm x 300mm High M 6

Powder Coated Aluminium Windows

Specialist Contractor Designed Aluminium Works

Notes:

(i) The Contractor is required to price separately the


component parts of the glazed aluminium works as
provided in these Bills.

(ii) Prices for aluminium works shall include everything


necessary for the complete design, fabrication, supply,
delivery and installation including all supports, fixing
accessories, flashings, cappings, matching hardware,
weather stripping opening lights, packing around and into
frames with cement mortar and pointing externally with
sealant properly caulked; installed strictly in accordance
with manufacturer's details and specifications by authorised
specialist.

(iii) Prices for glazing shall include everything necessary


for the complete installation including glazing beads,
gaskets or other approved equivalent, glass adaptors, setting
blocks and silicone glazing sealants.

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 8/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.8 - WINDOWS
Description Unit Qty Rate Amount
BILL NO. 3.8 - WINDOWS (Cont'd)

WINDOWS (Cont'd)

Notes: (Cont'd)

(iv) Price for windows shall include approved cylinder


lock, handles and other locking devices, friction stays and
all necessary hardware and accessories.

(v) All section and profiles of the aluminium door frames


shall be similar to the sample as approved by the Architect.
The tenderer are advised to view the said sample and to
allow for the necessary cost for compliance with the above
requirement.

(vi) Subframes are required for all aluminium frames.

(vii) The aluminium extrusions shall be in alloy 6063-TS


with a minimum thickness of 100mm

(viii) Powder coating shall be in grey colour, coated to a


minimum thickness of 80 microns.

The Contractor is required to comply with or furnish the


following information on his proposal for the aluminium
and glazing works:

Aluminium Extrusions Manufacturer :

Thickness of Aluminium Extrusions provided :

Thickness of Anodic Coating provided :

Name of Specialist Contractor :

Glazing Works:

(i) Manufacturer:

(ii) Thickness (unless otherwise stated):

(iii) Tint colour:

(iv) Gasket Brand:

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 8/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.8 - WINDOWS
Description Unit Qty Rate Amount
BILL NO. 3.8 - WINDOWS (Cont'd)

WINDOWS (Cont'd)

Powder Coated Aluminium Frame Glazed Windows

Supply and fix the following of approved powder coated


aluminium window frames of top hung window and fixed
panels; including supports, fixing accessories, complete
with approved galvanised steel gaskets, aluminium sub
frame, locking devices, friction stays and all other
neccessary ironmongery and accessories; packing around
and into frames and sealing joints around edges of frames;
all as per Architect's drawings and approval.

A Window type TW1 as top hung windows; to suit opening


size 600mm x 600mm high in one panel; including 6mm
thick tinted glass NO 1

B Window type FW5 as fixed glass window; to suit opening


size 2550mm x 1850mm high with corner in five equal
panels; including 6mm thick tinted glass NO 1

C Window type LW9 to suit opening size 600mm x 2000mm high in


two equal panels; 1 nos. as top hung window size 600mm x
1400mm high below and 1 nos. fixed glass panel size 600mm x
600mm high above; including 6mm thick clear glass NO 2

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 8/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.8 - WINDOWS
Description Unit Qty Rate Amount
BILL NO. 3.8 - WINDOWS (Cont'd)

COLLECTION

Page No. 8/1

Page No. 8/2

Page No. 8/3

BILL NO. 3.8 - WINDOWS

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 8/4
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.9 - WALL FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.9 - WALL FINISHES

WALL FINISHES

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

EXTERNAL WALL FINISHES

Plastering

Plastering; in cement and sand (1:3); with approved


plasticiser; applied in two coats; finished smooth with a
wood float

A 19mm Thick plainface to walls, beams and columns M2 31

B Extra Over for forming groove line on plastered wall M 78

Painting

Prepare and apply approved one coat sealer and approved


two coats weathershield paint strictly in accordance with
the manufacturer's specifications and instructions

C Walls, beams and columns M2 31

INTERNAL WALL FINISHES

Plastering

Cement and sand (1:6) as described internal rendering


finished with a steel trowel:

D 19mm Thick plainface rendering to sides of walls and columns M2 35

Cement and sand (1:6) as described as backing screed:

E To receive wall tiles; 20mm thick M2 10

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 9/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.9 - WALL FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.9 - WALL FINISHES (Cont'd)

WALL FINISHES (Cont'd)

INTERNAL WALL FINISHES (Cont'd)

Tiling Works

300mm x 300mm approved ceramic wall tiles; bedded and


jointed in cement mortar (1:3) with approved adhesive and
pointed in coloured cement mortar (1:3) in approved
design, colour and pattern on 19mm thick cement and sand
(1:6) screed backing (measured separately) to
manufacturer's instructions and approval of the Architect :

A To wall and columns M2 10

Painting

Prepare and apply approved one coat sealer and approved


two coats emulsion paint strictly in accordance with the
manufacturer's specifications and instructions

B Plastered walls and columns M2 35

Waterproofing System

Supply and apply approved cementitious waterproofing slurry


and protective coating; minimum two coats recommended by the
manufacturer; all scope of work carried out strictly in
accordance with the manufacturer's printed instructions and
recommendations by and approved specialist applicator with
and including providing ten (10) years warranty:

C Upturn; 300mm high (toilet area) M 4

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 9/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.9 - WALL FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.9 - WALL FINISHES (Cont'd)

COLLECTION

Page No. 9/1

Page No. 9/2

BILL NO. 3.9 - WALL FINISHES

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 9/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.10 - FLOOR FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.10 - FLOOR FINISHES

FLOOR FINISHES

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

EXTERNAL FLOOR FINISHES

Paving

Cement and sand (1:3) as described cement render,


levelled, trowelled hard and smooth to :-

A 25mm thick to apron slab M2 12

B Drop; not exceeding 100mm high M 19

INTERNAL FLOOR FINISHES

Cement and sand (1:3) as described bedding screed to :-

C 25mm thick to received floor tiles M2 8

D To drop; not exceeding 100mm high M 2

E To skirting M 10

Tiling Works

300mm x 300mm approved smooth homogenous floor tiles;


with PC unit supply rate of RM35.00/m2 as described, laid
with approved adhesive on 25mm thick cement and sand
(1:3) screeded beds (measured separately); to approved
colour bedded, jointed and pointed on to manufacturer's
instructions and approval of the Architect :

F To floors (Guard room) M2 6

G Skirting, 100mm high M 2

H Drop; not exceeding 100mm high M 1

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 10/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.10 - FLOOR FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.10 - FLOOR FINISHES (Cont'd)

FLOOR FINISHES (Cont'd)

INTERNAL FLOOR FINISHES (Cont'd)

300mm x 300mm approved non-slip homogenous floor


tiles; with PC unit supply rate of RM35.00/m2 as described
laid with approved adhesive on 25mm thick cement and
sand (1:3) screeded beds (measured separately); to
approved colour bedded, jointed and pointed on to
manufacturer's instructions and approval of the Architect :

A To floor (Toilet) M2 2

B To drop; not exceeding 100mm high M 1

Waterproofing System

Prepare and apply two (2) coats approved cementitious


waterproofing coating, including clearing of all concrete
surfaces to be applied and laid and finised all scope of work
carried out strictly in accordance with the manufacturer's
printed instructions and recommendations by and approved
specialist applicator with and including providing a ten (10)
years warranty:

C To floor tile (Toilet) M2 2

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 10/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.10 - FLOOR FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.10 - FLOOR FINISHES (Cont'd)

COLLECTION

Page No. 10/1

Page No. 10/2

BILL NO. 3.10 - FLOOR FINISHES

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 10/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.11 - CEILING FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.11 - CEILING FINISHES

CEILING FINISHES

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved" where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

1) All ceiling measured gross. No deduction made for light


fittings

2) Rate for ceiling shall include for supply, install and


finishing edges of ceiling to match wall and all necessary
plasterboard beading

INTERNAL CEILING FINISHES

Asbestos Free Cement Sheet Suspended Ceiling

Approved 1220mm x 610mm x 3.2mm suspended asbestos


free cement sheet ceiling as described with ceiling "T"
suspension system ceiling or other equivalent, complete
with all necessary metal support as runner, trimmings and
the like at junctions and joints and fixing accessories, fixed
to soffit of slab/ beam/ roof truss to manufacturer's details
and Architect's approval

A Ceiling soffit lining not exceeding 3.50m high (Guard room) M2 6

Plaster Board Suspended Ceiling

9mm thick approved plaster board ceiling with moisture


resistance finish as described with galvanised suspension
system ceiling or other equivalent, complete with all
necessary metal support as runner, trimmings and the like at
junctions and joints and fixing accessories, fixed to soffit of
slab/ beam/ roof truss to manufacturer's details and
Architect's approval

B Ceiling soffit lining not exceeding 3.50m high (Toilet) M2 2

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 11/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.11 - CEILING FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.11 - CEILING FINISHES (Cont'd)

CEILING FINISHES (Cont'd)

INTERNAL CEILING FINISHES (Cont'd)

Painting

Prepare and apply approved one coat sealer, and two coats
emulsion paint strictly in accordance with the
manufacturer's specifications and instructions

A To asbestos free cement sheet ceiling M2 6

B To plaster board ceiling M2 2

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 11/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.11 - CEILING FINISHES
Description Unit Qty Rate Amount
BILL NO. 3.11 - CEILING FINISHES (Cont'd)

COLLECTION

Page No. 11/1

Page No. 11/2

BILL NO. 3.11 - CEILING FINISHES

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 11/3
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION
Description Unit Qty Rate Amount
BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION

BUILDER'S WORK IN CONNECTION

Notes :

This Bill is to be read in conjunction with the Specification,


Preliminaries and Preambles to all Trades attached.

The word "approved " where used in the Bill means as


approved by the Architect

The word "as described" where used in the Bill means as


described in the above documents.

Sundries

A Sealing voids in slabs between inserts, bolts, sleeves, etc.


and the building structure; with concrete; complete with
reinforcement and dowel bars morticed into edges of slabs
and wall; including filling, grouting and making good under
such openings, chases and the like; all to the Engineer's
details and approval (The Mechanical & Electrical
Engineer and Civil & Structural Engineer shall supply the
inserts, bolts, sleeves, etc. and provide Contractor the
correct positions of these fittings) ITEM

ATP-Plot F-Package 11-Building Work To Collection RM


Bill No. 3 - Guard House 12/1
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION
Description Unit Qty Rate Amount
BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION (Cont'd)

COLLECTION

Page No. 12/1

BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION

ATP-Plot F-Package 11-Building Work Carried to Summary RM


Bill No. 3 - Guard House 12/2
PCMSB/2013/154/PF-P11-BW
PCM KOS PERUNDING SDN BHD SUMMARY
Description Unit Qty Rate Amount

SUMMARY Page No.

BILL NO. 3.1 - WORK BELOW LOWEST FLOOR FINISH 1/3

BILL NO. 3.2 - FRAME 2/2

BILL NO. 3.3 - UPPER FLOOR 3/2

BILL NO. 3.4 - ROOF 4/4

BILL NO. 3.5 - EXTERNAL WALLS 5/2

BILL NO. 3.6 - INTERNAL WALLS 6/2

BILL NO. 3.7 - DOORS 7/3

BILL NO. 3.8 - WINDOWS 8/4

BILL NO. 3.9 - WALL FINISHES 9/3

BILL NO. 3.10 - FLOOR FINISHES 10/3

BILL NO. 3.11 - CEILING FINISHES 11/3

BILL NO. 3.12 - BUILDER'S WORK IN CONNECTION 12/2

TOTAL AMOUNT TO FINAL SUMMARY