Vous êtes sur la page 1sur 2

DRILLING MACHINE

Data recorded

Table 5: Advance Stroke

P1Z1/bar P1Z2/bar P1Z3/bar


Advance Stroke 5 5 0
End Position 45 15 20
Advance Stroke with Counterpressure 15 15 20
End Position 45 50 0
Advance Stroke with Pressure Regulator 50 15 20
End Position 50 15 0

Table 6: Return Stroke

P1Z1 P1Z2 P1Z3


Return Stroke 5 15 25
End Position 5 15 30
Return Stroke with Counterpressure 5 15 25
End Position 5 0 45
Return Stroke with Pressure Regulator
End Position

FERRY LOAD RAMPING

Settings of the Hydraulic Circuit

1. System pressure is set to 50 bars.


2. The advance time is set to 5 s. This is done by varying the flow rate without any
loading and counter-holding with the flow control valve in the inlet line.
3. To set the counter-holding, flow control valve in the outlet is used.

Data recorded

Table 7: Flow Control Valve in Inlet Line

P0Z1/bar P1Z1/bar P1Z2/bar t/s


Without load without counter-holding 50 0 0 5
Without load with counter-holding 50 7 11 5
With load and counter-holding 50 3 10 5
With load without counter-holding 50 0 0 1

Table 8: Flow Control Valve in Outlet Line

P0Z1/bar P1Z1/bar P1Z2/bar t/s


Without load 50 47 78 5
With load 50 49 83 3

Values of time have been given to zero decimal places because these will not cause any large
deviations and help us understand the analysis better.