Advance Stroke 5 5 0 End Position 45 15 20 Advance Stroke with Counterpressure 15 15 20 End Position 45 50 0 Advance Stroke with Pressure Regulator 50 15 20 End Position 50 15 0
Table 6: Return Stroke
P1Z1 P1Z2 P1Z3
Return Stroke 5 15 25 End Position 5 15 30 Return Stroke with Counterpressure 5 15 25 End Position 5 0 45 Return Stroke with Pressure Regulator End Position
FERRY LOAD RAMPING
Settings of the Hydraulic Circuit
1. System pressure is set to 50 bars.
2. The advance time is set to 5 s. This is done by varying the flow rate without any loading and counter-holding with the flow control valve in the inlet line. 3. To set the counter-holding, flow control valve in the outlet is used.
Data recorded
Table 7: Flow Control Valve in Inlet Line
P0Z1/bar P1Z1/bar P1Z2/bar t/s
Without load without counter-holding 50 0 0 5 Without load with counter-holding 50 7 11 5 With load and counter-holding 50 3 10 5 With load without counter-holding 50 0 0 1
Table 8: Flow Control Valve in Outlet Line
P0Z1/bar P1Z1/bar P1Z2/bar t/s
Without load 50 47 78 5 With load 50 49 83 3
Values of time have been given to zero decimal places because these will not cause any large deviations and help us understand the analysis better.