Vous êtes sur la page 1sur 2

Sun Blade 1000 - Repair Procedures http://shrubbery.net/~heas/sun-feh-2_1/Systems/SunBlade1000/repair.

html

Sun System Handbook Home | Systems | Components | General Info | Search | Feedback

Sun Blade[tm] 1000 Workstation: Repair


Procedures
This section provides the most common repair procedures for the Sun Blade 1000 and Sun Blade 2000
workstations, which are included in the following manual:

Sun Blade 1000 and Sun Blade 2000 Service Manual (816-3217)

The following table provides the page numbers for each procedure.

Component Remove Install Tips


DVD-ROM Drive 7-5 7-6
Guidelines for understanding and diagnosing UltraSPARC
III Level 2 (L2) SRAM Cache Memory Errors (FIN
CPU Module 8-6 8-12 I0887-1).
Checking torque on Sun Fire [TM] 280R, Sun Blade
[TM]1000 and 2000 CPU modules (Infodoc 48429).

Power management issue causes loss of access to internal


fiber channel disks on the Sun Blade 1000/2000, Sun Fire
V880, V480, and 280R (FIN I0888-1).
Seagate ST336605FC 36GB and ST373405FC 73G drives
could be susceptible to label corruption (FIN I0816-1).
Error installing Solaris on ST318304 FC-AL disk drives:
Disk Drive 7-2 7-3
Could not create Solaris disk label (VTOC) (SRDB
24407).
Recovering from a failed FCAL boot disk (SRDB 17643).
Correcting device paths when replacing fiber boot disks
after a ufsrestore (Infodoc 40133).

Fan Assemblies 6-22 6-23


FC-AL Backplane
Assembly (contains 6-28 6-29
Disk Drives)
Floppy Drive 7-9 7-10
SunBlade 1000/2000 and Ultra 60/80 systems may exhibit
Graphics Card 8-26 8-27 a blank screen upon boot up with an XVR-1000 Graphics
Accelerator installed (FCO A0200-1).

1 of 2 8/3/2016 2:21 PM
Sun Blade 1000 - Repair Procedures http://shrubbery.net/~heas/sun-feh-2_1/Systems/SunBlade1000/repair.html

Too many Memory DIMMs are being unnecessarily


replaced on UltraSPARC III family of systems utilizing
NG-DIMM memory (FIN I0760-1).
Sun Blade 1000 workstations with 128MB DIMMs may
have intermittant Single Bit Correctable Errors (FCO
Memory 8-31 8-34
A0181-1).
New 256MB and 512MB LC1 DIMMs are now available
ONLY for the Sun Blade 1000/2000 and Sun Fire 280R
platforms (FIN I0883-1).

UltraSPARC III systems may panic due to a conflict


between the Schizo 2.4 ASIC and the GigaSwift Ethernet
PCI Card (FIN I0874-1).
PCI Card 8-20 8-22
SunPCi II and SunPCi IIpro cards may not respond after
rapid/successive power cycling (FCO A0186-1).

Peripheral Assembly
(contains
DVD-ROM/tape, 7-3 7-10
smart card, and
floppy drive)
Power Supply
6-1 6-4
Assembly
Replaceable Battery 8-35 8-35
Solaris 8 patches required for Smart Card Reader
operation on Sun Blade 100, 1000, and 2000 systems
Smart Card Reader 7-7 7-8
(FIN I0868-1).

UltraSPARC III and III+ based platforms could be


susceptible to UCC errors that may cause system panics
System Board 8-37 8-39
(FIN I0856-1).

Tape Drive 7-5 7-6

Copyright 1994-2003 Sun Microsystems, Inc., 901 San Antonio Road, Palo Alto, CA 94303 USA. All rights reserved.
Legal Terms Privacy Policy Feedback

2 of 2 8/3/2016 2:21 PM