Vous êtes sur la page 1sur 42

lindab | residential ventil ation

Circular duct systems

Residential ventilation 1

Circular duct systems 2

Hoods, grilles and transitions 3

Dampers 4

Silencers 5

Valves and Grilles 6

InCapsa 7

InDomo 8

Access doors 9

Accessories 10

Air handling units 11

Index 12

13

14

15

16

17

18
lindab | resid ential ven tilati on

Content
Circular duct Female
SR............................................................... 6 couplings MF............................................................. 37
1 SMFU........................................................ 39

2
Bends
BU 90........................................................ 9
BU 60...................................................... 11
End caps
3 BU 45...................................................... 13
EPF ........................................................... 40
BU 30...................................................... 15
BU 15...................................................... 17
BFU 90.................................................... 10
4 BFU 60.................................................... 12
BFU 45.................................................... 14
BFU 30.................................................... 16
BFU 15.................................................... 18 Wall stubs
5 TVILU ........................................................ 44
BKU90 .................................................... 19
BKFU 90 ................................................. 20
BKMU 90 ................................................ 21
6
BU GJUT ................................................. 22
BSIU GJUT.............................................. 23
7

8 Reducers
RCU.......................................................... 24
RCFU........................................................ 25

10 Rect-to-round
transition
LORU........................................................ 27

11

12 T-pieces
TCPU........................................................ 28
TCPMU..................................................... 31
TCSIU GJUT............................................ 32
13 TCPU GJUT ............................................ 33
TCPU GIPS ............................................. 33
TCPU KORT ............................................ 35

14 Take-offs
ILRU ......................................................... 41
ILU............................................................ 42
ILF ............................................................ 43
15

16 Couplings
NPU.......................................................... 36
SNPU ....................................................... 38

17

18

4 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Circular duct systems


The Safe-system Tightness
Safe is a quickly assembled system for round ventila- A duct system will never be completely tight. The system 1
tion ducts. will normally have some leaks at joints between ducts and
Safe is type approved to class D by SITAC, no. 1358/ fittings. The leakage will also increase as the pressure
88. difference between the in- and outside of the duct sides
The complete programme has dimensions according 2
increases.
to Eurovent 2/3 and Swedish Standard SS-EN 1506.
The system is based on a double-lipped, factory- The leakage factor in (l/s)/m2 is always specified in relation
installed seal made from EPDM rubber. The moulding, to the pressure difference in Pa. (The unit (l/s)/m2 denotes 3
which can withstand rough handling, and is almost the leakage flow in l/s in or out of the system in relation to its
insensitive to temperature changes, gives a very air- duct area in m2.) The graph below shows the leakage factor
tight seal. for the sealing classes AD as a function of the pressure dif- 4
ference.
Advantages of the Safe-system
4,0 A
Quick assembly.
Factory fitted seal with no loose fittings.
5
Can be twisted and adjusted with tightness 1,32
B
unaffected. 1,0
Installation without sealant or solvents. 0,5 0,44 6
Can be used in all climates. C
[(l/s)/m2]

Seal moulding remains tight from 5 000 Pa negative


pressure to 3 000 Pa positive pressure. 0,15
Duct resistance to collapse differs from these pres-
D 7
0,1
sures, and is noted on page 49. 0,05
Type approved to sealing class D. 0,05
8
Click function
The Click function exists in principle on all Safe-products. 0,01
The exeptions are stated under each product.
50 100 400 500 1000 2000 9
[Pa]
The Click function exists on the dimensions 80315.
The Click function means; The graph shows that sealing class D is 3 times better than
a. that an end with male measure has an open turned-over class C, which in turn is 3 times better than class B etc. 10
end and Class D thus entails demands on not only the seal moulding
b. that an end with female measure has a number of but also the fittings and how well the system is installed.
notches. 11
This is one reason why we have given all fittings a turned-
over edge and have given still more fittings a stop bead.
Type approval
This gives us stable products which are better suited to
Approval no 1358/88 means that the Safe-system complies withstand handling on site at the same time as the risk of
12
with the requirements for tightness class D without any skewed assembly falls.
demand for pressure testing after installation.
The approval is only valid on condition that all fittings are 13
marked by us in accordance with the example and are
installed in accordance with the accompanying installation
instruction. 14
Marking Turned-over edge design
Each individual product is marked with a special label or 15
stamped in the metal.

Lindab Safe Click 16


1819/533/90
TG 1358/88

BU 125 90 GALV
4 6
7 9
88
TG

7 9 1358/
TG 1358/88
17

18

We reserve the right to make changes without prior notice 5


lindab | resid ential ven tilati on

Circular duct SR
Dimensions
1 l

t
2

d
3
l

t
4

d*
5

6 Description
Circular duct. d O A t l ml
std d d/4 std std std
Ducts are always produced locally and can therefore have nom m m2 mm mm kg/m
7 different thicknesses and other specifications per country. 63 0,198 0,003 0,5 3000 0,89
The ducts can be produced both with and without click 80 0,251 0,005 0,45 3000 0,91
function (notches). 100 0,314 0,008 0,45 3000 1,14
8 Please specify when ordering.
125 0,393 0,012 0,45 3000 1,41
160 0,503 0,020 0,5 3000 2,02
9 200 0,628 0,031 0,5 3000 2,56
250 * 0,785 0,049 0,5 3000 3,18
315 * 0,990 0,078 0,55 3000 4,41
10 * With outturned stiffening corrugation.

11

12

13

14

15

16 Ordering example
SR 200 3000 CLIC
Product
17
Dimension d
Length l
Type
18

6 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Circular duct SR
Technical data
1
[Pa/m]
200
2
100 20

63
80
15

0
50

10
d

5
3

12
[mm

0
10

16

0
0
]

20
25

5
31
]
/s

0
40
m

0
4

50
v[

10

0
63
5

0
80
5 4

00
50
10
3 5

12
pt

2
1 6
0.5

7
0.1
8
0.05

0.02 9
5 10 50 100 500 1000 5000 10000 50000 [l/s]

10 50 100 500 1000 5000 10000 50000 100000 [m3/h]


10
q

11

12

13

14

15

16

17

18

We reserve the right to make changes without prior notice 7


lindab | resid ential ven tilati on

Circular duct SR
Technical data
1
Special versions Strength
We can supply ducts with the following special designs: Positive pressure
2 In intermediate dimensions, see page . in case of high positive pressure, the seal moulding lips will
Extra tight, with nitrile rubber seal in the lock seam first start to whistle. At considerably higher pressure, the
In other sheet metal thicknesses joints between the ducts will be forced apart. If you manage
Extra tight, with seam seal to fix the connections very well, the ducts will burst at their
3 seams at even higher pressure. The high pressures needed
When extremely good sealing is required in the spiral seam,
the ducts can also be supplied with a special rubber seal in for this to happen are not relevant to ventilation installations.
the seam. Negative pressure
4 In installations with high negative pressure, there is a risk
This seal is very effective at stopping leakage of vegetable
oils and greases, and most petroleum products including that the ducts could collapse.
white spirit. This phenomenon is referred to as buckling, and can sud-
5 denly happen at the weakest point in the system. Buckling
Other sheet metal thicknesses
If extra stability is needed in ducts, because of high negative wanders along the duct, which can be completely flattened.
pressure etc., they can be supplied with thicker sheet metal The weakest point is frequently a "transport dent" on a duct.
6 than standard. Remember that the thickness increase For this reason, only use undamaged ducts in systems
always reduces the inner diameter. Fittings for such special which are close to the critical pressure!
ducts must be specified separately and sometimes have to Sealing
7 be made specially. The ability of the seal moulding to seal is different from
Reinforcement corrugations these pressures, and is noted on page .
Ducts of 250 mm and above are normally given stiffening
8 corrugations to increase radial stiffness.

10

11
Collapsing pressure for duct SR
Diameter 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250
12 Sheet metal 0,5 0,45 0,45 0,45 0,5 0,5 0,5 0,55 0,55 0,7 0,7 0,8 0,9 0,9

Without stiffening corrugations With stiffening corrugations


13 0
-1,0 -0,8
-4,3 -3,0 -3,5 -3,0 -3,2
-10 -7,2 -4,8
Negative
14 pressure
-11,7
-20 -17,0
-21,4
-30
15
-40
-40,4 *
16 -50 -47,0 *
* Collapse not achieved
[kPa] -60
17
63 80 100 125 160 200 250 315 400 500 630 800 1000 1250

18

8 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend BU 90
Dimensions
l 1

rm

l

4
d1
5
r m 1d 1

Description d1 l m 6
Pressed and seam welded bend. nom mm kg
63 110 0,20
d1 [mm]
63 80 100 125 160 200 250 80 105 0,26 7
100
100 100 0,31
50 125 125 0,48
160 160 0,74 8
200 200 1,12
pt [Pa]

10 250 250 1,77


9
5

10
1
10 50 100 500 1000 3000 [l/s]
50 100 500 1000 5000 10000 [m3/h] 11
q

12

13

14

15

Ordering example 16
BU 100 90
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 9


lindab | resid ential ven tilati on

Bend lockseamed BFU 90


Dimensions
1
l

l
rm

4
d1
5 r m 1d 1

6 Description d1 l m
Segmented and lockseamed bend. nom mm kg
250 250 2,20
d1 [mm]
7 250 315 400 500 630 315 315 3,00
100

50
800
8
1000
pt [Pa]

10
9 1250
5

10
1
100 500 1000 5000 10000 [l/s]

11 500 1000 5000 10000 [m3/h]

12

13

14

15

16 Ordering example
BFU 315 90
Product
17 Dimension d1
Angle

18

10 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend BU 60
Dimensions
1
l

rm 3

4
d1

r m 1d 1
5

Description d1 l m 6
Pressed and seam welded bend. nom mm kg
63 64 0,30
d1 [mm]
63 80 100 125 160 200 250 80 58 0,32 7
70
50 100 58 0,33
125 72 0,33
160 92 0,56 8
200 115 0,82
10
250 144 1,12
pt [Pa]

5 9

10
1
0,7
10 50 100 500 1000 3000 [l/s]
50 100 500 1000 5000 10000 [m3/h] 11
q

12

13

14

15

Ordering example 16
BU 125 60
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 11


lindab | resid ential ven tilati on

Bend lockseamed BFU 60


Dimensions
1
l
2

3
rm

l

4
d1
r m 1d 1
5

6 Description d1 l m
Segmented and lockseamed bend. nom mm kg
250 144 1,48
d1 [mm]
7 70
250 315 400 500 630 315 182 2,20
50
800
8
1000
pt [Pa]

10

9 5 1250

10
1
0,7
100 500 1000 5000 10000 [l/s]

11 500 1000 5000 10000 [m3/h]

12

13

14

15

16 Ordering example
BFU 315 60
Product
17 Dimension d1
Angle

18

12 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend BU 45
Dimensions
1

l
2

rm 3

4
d1
r m 1d 1
5

Description d1 l m 6
Pressed and seam welded bend. nom mm kg
63 46 0,16
d1 [mm]
63 80 100 125 160 200 250 80 41 0,17 7
50
100 41 0,21
125 52 0,29
160 66 0,48 8
10 200 83 0,80
250 103 1,05
pt [Pa]

5
9

1 10
0,5
10 50 100 500 1000 3000 [l/s]
50 100 500 1000 5000 10000 [m3/h] 11
q

12

13

14

15

Ordering example 16
BU 125 45
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 13


lindab | resid ential ven tilati on

Bend lockseamed BFU 45


Dimensions
1

l
3
rm

l
4
d1
r m = 1d 1

6 Description d1 l m
Segmented and lockseamed bend. nom mm kg
250 104 1,26
d1 [mm]
7 250 315 400 500 630 315 130 1,90
50

800
8
10 1000
pt [Pa]

5
9 1250

10 1

0,5
100 500 1000 5000 10000 [l/s]

11 500 1000 5000 10000 [m3/h]

12

13

14

15

16 Ordering example
BFU 315 45
Product
17 Dimension d1
Angle

18

14 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend BU 30
Dimensions
1

l
rm 3

l
4
d1
r m 1d 1
5

Description d1 l m 6
Pressed and seam welded bend. nom mm kg
63 29 0,13
d1 [mm]
63 80 100 125 160 200 250 80 27 0,15 7
30
100 27 0,18
125 33 0,20
10
160 43 0,32 8
5 200 54 0,62
250 67 0,91
pt [Pa]

9
1

0,5 10
0,3
10 50 100 500 1000 3000 [l/s]
50 100 500 1000 5000 10000 [m3/h] 11
q

12

13

14

15

Ordering example 16
BU 125 30
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 15


lindab | resid ential ven tilati on

Bend lockseamed BFU 30


Dimensions
1

l
3
rm

l
4 d1
r m = 1d 1

6 Description d1 l m
Segmented and lockseamed bend. nom mm kg
250 67 1,00
d1 [mm]
7 250 315 400 500 630 315 84 1,42
30

800
8 10

5 1000
pt [Pa]

9 1250

10 0,5
0,3
100 500 1000 5000 10000 [l/s]

11 500 1000 5000 10000 [m3/h]

12

13

14

15

16 Ordering example
BFU 315 30
Product
17 Dimension d1
Angle

18

16 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend BU 15
Dimensions
1

l

rm
3

l
d1
4
r m 1d 1

Description d1 l m 6
Pressed and seam welded bend. nom mm kg
63 * 14 0,09
d1 [mm]
63 80 100 125 160 200 80 * 13 0,11 7
20
100 13 0,15
10 125 16 0,18
160 21 0,24 8
5
200 26 0,47
pt [Pa]

* Segmented and lockseamed 9


1

0,5
10
0,2
10 50 100 500 1000 3000 [l/s]
50 100 500 1000 5000 10000 [m3/h] 11
q

12

13

14

15

Ordering example 16
BU 125 15
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 17


lindab | resid ential ven tilati on

Bend lockseamed BFU 15


Dimensions
1

l

3 rm

l
d1
4
r m =1d 1

6 Description d1 l m
Segmented and lockseamed bend. nom mm kg
250 33 0,65
d1 [mm]
7 250 315 400 500 315 41 0,91
20
630
10
8 5 800
pt [Pa]

9 1000

1
1250
0,5
10
0,2
100 500 1000 5000 10000 [l/s]

11 500 1000 5000 10000 [m3/h]

12

13

14

15

16 Ordering example
BFU 315 15
Product
17 Dimension d1
Angle

18

18 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend short BKU90


Dimensions
l 1

l
rm
4

d1
5
r m 0,6d 1

Description d1 l m 6
Pressed and seam welded bend with short installation nom mm kg
length. 80 80 0,14

d1 [mm]
100 62 0,22 7
125 79 0,31
0
5
0
80
10
12
16

100 160 94 0,50


8
50

9
pt [Pa]

10
5
11

1 12
10 50 100 500 1000 [l/s]
50 100 500 1000 [m/h]
q 13

14

15

Ordering example 16
BKU 100 90
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 19


lindab | resid ential ven tilati on

Bend short, lockseamed BKFU 90


Dimensions
1 l

l
rm
4

d1
5 r m 0,6d 1

6 Description d1 l m
Segmented and lockseamed bend with short installation nom mm kg
length. 200 158 1,18
7 d1 [mm] 250 180 1,64
315 220 2,49
0
0
0
5

0
0
0
40
20
25
31

50
63
80
00

100
8
10

50
50
12

9
pt [Pa]

10
10
5

11
1
50 100 500 1000 5000 10000 [l/s]
12 500 1000 5000 10000 [m/h]
q

13

14

15

16 Ordering example
BKFU 250 90
Product
17 Dimension d1
Angle

18

20 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend Casting-in BKMU 90


programme
Dimensions
l 1

d
3

l1
rm
4
d1
r m = 0,6d 1 5

Description d1 d l l1 m 6
Pressed and seam welded bend with short installation nom nom mm mm kg
length and female end. 80 80 123 80 0,13
Has Click function at the Safe end has an open turned- 100 100 105 62 0,21 7
over end. 125 125 120 79 0,31
Has not any Click function at the female end hasnt any
160 160 136 94 0,63
notches. 8
d1 [mm]
0
5
0
80
10
12
16

100
9
50

10
pt [Pa]

11
5
12

1
10 50 100 500 1000 [l/s]
13
50 100 500 1000 [m/h]
q
14

15

Ordering example 16
BKMU 100 90
Product
Dimension d1
17
Angle

18

We reserve the right to make changes without prior notice 21


lindab | resid ential ven tilati on

Bend Casting-in BU
programme
Dimensions
1
l
2

d inv
3

l1
4
d1
5

6 Description d1 d l l1 m
Short installation length with female end and nail flange with nom nom mm mm kg
pre-punched holes. 80 80 101 80 0,26
7 100 100 93 62 0,24
125 125 106 79 0,32
160 160 130 94 0,43
8

10

11

12

13

14

15

16 Ordering example
BU 100 90 GJUT
Product
17 Dimension d1
Angle
Specification
18

22 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Bend Casting-in BSIU


programme
Dimensions
1
l
2

d
3

l1
4
d1
5

Description d1 d l l1 m 6
Short installation lenght with air valve socket and nail flange nom nom mm mm kg
with pre-punched holes. Fits air valve KVB etc. 100 92 93 62 0,23
125 117 106 79 0,31 7
160 152 131 94 0,39

10

11

12

13

14

15

Ordering example 16
BSIU 100 90 GJUT
Product
Dimension d1 17
Angle
Specification
18

We reserve the right to make changes without prior notice 23


lindab | resid ential ven tilati on

Reducer RCU
Dimensions
1
l
l
2

d2

d2
d1

d1
4

6 Description d1 d2 l m
Pressed, concentric reducer to meet demands for short nom nom mm kg
installation length with low pressure drop and low internal 80 63 18 0,12
noise generation.
7 100 63 30 0,17
Pressure drop, see graphs on page 26. 100 * 80 26 0,18
125 * 80 36 0,16
8 125 * 100 27 0,21
160 80 55 0,31
160 * 100 46 0,17
9 160 * 125 35 0,22
200 * 100 46 0,22
10 200 * 125 55 0,30
200 * 160 39 0,29
250 125 70 0,62
11 250 * 160 60 0,46
250 * 200 42 0,46
315 160 91 0,86
12 315 * 200 74 0,72
315 * 250 50 0,65

13 * With stream-lined transition

14

15

16 Ordering example
RCU 315 250
Product
17 Dimension d1
Dimension d2

18

24 We reserve the right to make changes without prior notice


lindab | i ndomo

Reducer RCFU
Dimensions
1

d2
l
4

Description d d2 l m 6
Pressed, concentric reducer with female coupling, with a nom nom mm kg
45 angle to meet demands for short installation length with 80 63 57 0,11
low pressure drop and low internal noise generation. d fits
outside another fitting.
80 76 50 0,11 7
100 63 70 0,14
Pressure drop, see graphs on page 26.
Has Click function at the Safe end has an open turned- 8
over end.
Has normally not any Click function at the female end
hasnt any notches. 9
Can to order be delivered with Click function at the female
end as well i.e. with notches.

10

11

12

13

14

15

Ordering example 16
RCFU 315 250
Product
Dimension d 17
Dimension d2

18

We reserve the right to make changes without prior notice 25


lindab | resid ential ven tilati on

Reducers RCU, RCFU


Technical data
1
1 dimension step
2 [Pa]
v v
d [Pa]
1 d d

63
80
100 2 [mm 100 1 d

0
5

80
160 00

10
] 2 [mm
12

100
80

15
63

16
1

]
3

5
315 00

125

250 60
50 50

12
0
80

125
100

0
315 0

0
630 00
2
25
200

25
500 15

1
20

50
500 5
9 630 00

/s]

160
250

4
31
0

200
3

8 10
/s]

50
4

v [m
400

7 9

400
v [m

6 8
7
4 10
5
10 6

pt
pt

4 5
4
5 3 5
3
5 2

1 1
6 10 50 100 500 1000 5000 10000 [l/s] 10 50 100 500 1000 5000 10000 [l/s]

50 100 500 1000 5000 10000 [m3/h] 50 100 500 1000 5000 10000 [m3/h]
q q

7 2 dimension steps

v d d
1 d v 1 d
[Pa]
8 [Pa]
125 3
2 [mm 80 2 [mm
6

500 50
] 10 ]

400 00

5
0

100

0
315 0

100
250 25

315160
100
200 00

2
31
20

40
16

2
12
0

160
1

15
1

25

630 315

630
80

250
160

200
40

50
125 3

50
400

500

9
/s]

10
100

v [m

9
6 8
/s]

7
v [m

5
6
pt

10 4 10 5
10
pt

3
5 5
2
11
1 1
10 50 100 500 1000 5000 10000 [l/s] 10 50 100 500 1000 5000 10000 [l/s]
12 50 100 500 1000 5000 10000 [m3/h] 50 100 500 1000 5000 10000 [m3/h]
q q

3 dimension steps
13
d1 d1
d2 [m v d2 [m
200 80

v m]
400 60
0
315 5

m]
0
10
12

630 50
5

[Pa]
500 00
400 60

20
1

[Pa]
160

31
0
315 5

14
5

2
25
12

2
1

31
250100

250

15
500

100
200 0

100
630
8

/s]
160

10
v [m

50 4 50
9
15 8
/s]

3
v [m

2
10
pt

10
pt

16
5 5

17
1 1
10 50 100 500 1000 5000 10000 [l/s] 10 50 100 500 1000 5000 10000 [l/s]

18 50 100 500 1000 5000 10000 [m3/h] 50 100 500 1000 5000 10000 [m3/h]
q
q

26 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Rect-to-round transition LORU


Dimensions
1
1

d1
b
a l 3
2 3

5
5
4

Description 6
Rect-to-round transition are used between rectangular and
circular ducts. The rectangular connection has joining pro-
files type RJFP and the circular connection has Safe seal. 6
The rectangular connection is available with offsets as in the
7

h
coded sketches.
Measures e and h only need to be given for alternative 6. 8

b
Negative values for e, for example, mean that e is outside
side a.
The Rect-to-round transition LORU can also be manufac- e
a
9
tured with other designs of the circular connection. It then
changes name as follows:
LORNP: Transition with male coupling (without gasket)
l
10
LORMF: Transition with female coupling
a std
LORFL: Transition with flange coupling mm mm
100 300 11
150 300
200 300
250 300 12
Ordering example 300 300
LORU 500 300 160 450 1 ..... ..... 350 300
Product 400 450 13
Largest side a 450 450
Smallest side b 500 450
Diameter d1 600 450 14
Length l 700 450
The alternative dis- 800 600
placements are seen
from the circular end 1 6
900 600 15
1000 600
Displacement e (Only at alternative 6.)
1100 600
Displacement h (Only at alternative 6.)
1200 600 16
1300 600
1400 600
1500 600 17
1600 600
1800 600
2000 600 18

We reserve the right to make changes without prior notice 27


lindab | resid ential ven tilati on

T-piece TCPU
Dimensions
1
d3

l3
d1
4
l
5
d1 d3 l l3 m
nom nom mm mm kg
6 Description 63 63 125 42 0,26
T-piece built with PSU saddle or a fully pressed top section. 80 63 125 50 0,31
80 80 140 52 0,36
7 100 63 125 60 0,35
100 80 103 65 0,23
100 100 130 65 0,32
8 125 80 97 75 0,34
125 100 130 78 0,37
125 125 165 83 0,44
9
160 80 140 92 0,59
160 100 130 95 0,46
10 160 125 166 100 0,53
160 160 209 105 0,63
200 100 175 115 0,88
11 200 125 215 115 1,02
200 160 209 125 0,67
200 200 249 125 1,21
12 250 125 220 145 1,48
250 160 256 150 1,58
250 200 306 150 1,78
13 250 250 296 150 1,65
315 160 256 182 1,96
315 200 306 182 2,14
14
315 250 350 182 2,59
315 315 363 182 2,20
15

16 Ordering example
TCPU 250 160
Product
17 Dimension d1
Dimension d3

18

28 We reserve the right to make changes without prior notice


lindab | residential ventil ation

T-piece TCPU
Supply air
1
Diverging flow [Pa]
200 2
100
d3 v3 m/s
50 3
14
d1 d2 12
pt

10 4
10 8
6
5
5
4

1 2 6
0 2 4 6 8 10 12 14 [m/s]
v1

Diverging flow
7
[Pa]
2 4
30
6
d3 20 14 16
v2 [ m s ] 8
v1
<1
/s ]
[ m/ 8
v2 12 v2 10
10
10 12
d1 d2 9
5
pt

6
The diagram is also applicable to
2
10
reduction in d2. v1
>1
4 v2
1
11
0 2 4 6 8 10 12 14 16 [m/s]
v1 12
Diverging flow [Pa] v3 [ m/s ]
200
16
13
14
d3 100 12
10 14
50
pt

8
d1 d2

20
6 15
4
10
16
5
2
0 2 4 6 8 10 12 14 16 [m/s]
17
v 1 = v2

18

We reserve the right to make changes without prior notice 29


lindab | resid ential ven tilati on

T-piece TCPU
Exhaust air
1

2 Converging flow
[Pa]
100

d3
3
50
d1 d2
4
pt

v2 [ m/s ]

5 0
4
6
8
6 -40
10 12 14 16
0 2 4 6 8 10 12 14 16 [m/s]

v3
7
Converging flow
[Pa] 2 4
6
8 50
v1 [ m/s ]
16
[ m/
s]
10
14 v1
d3 12
12
20
9 v1
<1
10
d1 d2 v2 8
10
pt

v1
>1
10 The diagram is also applicable 5
6 v2

to reduction in d1.
4
11 2

1
0 2 4 6 8 10 12 14 16 [m/s]
12
v2

13 Converging flow [Pa]


200
v3 m/s
100
14 d3 14
12
50
10

8
15 d1 d2
pt

6
10
4
16 5

17 2

1
0 2 4 6 8 10 12 14 [m/s]
v1 = v2
18

30 We reserve the right to make changes without prior notice


lindab | residential ventil ation

T-piece TCPMU
Dimensions
d3 1

l3
3

d1
4

l
5

Description d1 d3 l l3 m 6
Centric T-piece with female coupling for joining fittings. nom nom mm mm kg
Fits very well with Lindab InCapsa. 100 100 130 100 0,31

Has Click function at the Safe ends has an open turned-


125 100 130 113 0,32 7
over ends. 125 125 165 121 0,43
Has normally not any Click function at the female end 160 100 130 128 0,46
hasnt any notches. 160 125 165 137 0,53 8
100160 can upon order be delivered with click function 160 160 209 141 0,63
at the female end as well i.e. with notches.
9

10

11

12

13

14

15

16
Ordering exaple
TCPMU 125 100 17
Product
Dimension d1
Dimension d3
18

We reserve the right to make changes without prior notice 31


lindab | resid ential ven tilati on

T-piece Casting-in TCSIU


programme
Dimensions
1

d3
l
3

4
l3
5 d1

6 Description d1 d3 l l3 m
Short branch with air valve socket and nail flange with pre- nom nom mm mm kg
punched holes. 100 100 130 93 0,31
7 Fits air valve KVB etc. 125 100 130 106 0,52
125 125 165 106 0,67
160 160 229 131 1,02
8

10

11

12

13

14

15

16 Ordering example
TCSIU 100 100 GJUT
Product
17 Dimension d1
Branch d3
Specification
18

32 We reserve the right to make changes without prior notice


lindab | residential ventil ation

T-piece Casting-in TCPU


programme
Dimensions
1

d3
l
3

4
l3
d1 5

Description d1 d3 l l3 m 6
Short branch with female end and nail flange with pre- nom nom mm mm kg
punched holes. 80 * 80 140 80 0,38
100 100 130 93 0,30 7
125 100 130 106 0,50
125 125 165 102 0,59
160 160 209 130 0,88 8
* Made with saddle PS
9

10

11

12

13

14

15

Ordering example 16
TCPU 100 100 GJUT
Product
Dimension d1 17
Branch d3
Specification
18

We reserve the right to make changes without prior notice 33


lindab | resid ential ven tilati on

T-piece Casting-in TCPU


programme
Dimensions
1

d3
l
3

4
l3
5 d1

6 Description d1 d3 l l3 m
Short branch with female end. nom nom mm mm kg
80 * 80 140 80 0,33
7 100 100 130 85 0,27
125 100 130 100 0,44
125 125 165 100 0,53
8 160 160 229 117 0,82

* Made with saddle PS


9

10

11

12

13

14

15

16 Ordering example
TCPU 100 100 GIPS
Product
17 Dimension d1
Branch d3
Specification
18

34 We reserve the right to make changes without prior notice


lindab | residential ventil ation

T-piece Casting-in TCPU


programme
Dimensions
1

d3
l
3

4
l3
d1
5

Description d1 d3 l l3 m 6
Short branch and short installation lengths. nom nom mm mm kg
100 100 130 65 0,32
125 125 165 83 0,44 7
160 160 210 105 0,63

10

11

12

13

14

15

Ordering example 16
TCPU 100 100 KORT
Product
Dimension d1 17
Branch d3
Specification
18

We reserve the right to make changes without prior notice 35


lindab | i ndomo

Coupling NPU
Dimensions
1

d1
3

55
4

6 Description d1 m
Coupling connector for joining circular ducts. nom kg
63 0,07
7 76 0,09
80 0,09

10

11

12

13

14

15

16 Ordering example
NPU 80
Product
17 Dimension d1

18

36 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Female coupling MF
Dimensions
1

2
l

d
4

Description d l m 6
Female coupling for joining fittings. nom mm kg
Has normally not any Click function hasnt any notches. 63 * 95 0,06
Can to order be delivered with Click function i.e. with 80 * 95 0,08 7
notches. 100 * 95 0,10
125 * 95 0,13
160 * 95 0,20 8
200 * 95 0,25
250 * 140 0,42
315 * 140 0,54
9

* With turned-over edge


10

11

12

13

14

15

Ordering example 16
MF 200
Product
Dimension d 17

18

We reserve the right to make changes without prior notice 37


lindab | resid ential ven tilati on

Slide-in coupling SNPU


Dimensions
1

l = 710
2

d1
4
li

6 Description d1 L li m
Areas of use: nom nom mm kg
To eliminate the accurate length cutting of ducts which 80 150 133 0,18
7 the ordinary NPU connector sometimes requires when 80 300 284 0,32
joining SR ducts. In this case the slide-in coupling
shall be secured with screws or pop rivets. 80 500 548 0,69
To make it possible to use a duct that is cut to a too 100 150 133 0,22
8 short length instead of having to cut a new duct to 100 300 284 0,40
the correct length. In this case the slide-in coupling 100 500 548 0,84
shall be secured with screws or pop rivets.
125 150 133 0,28
9 To assist when joining two ducts which run towards
125 300 284 0,50
each other. E.g. when building a system from two
opposing directions. In this case the slide-in coupling 125 500 548 1,07
shall be secured with screws or pop rivets. 160 150 133 0,36
10 To assist when inserting or adding an other product
160 300 284 0,65
into an existing system. E.g. the addition of a new
piece of duct to replace a damaged part. In this case 160 500 548 1,38
11 the slide-in coupling shall be secured with screws or 200 150 133 0,56
pop rivets. 200 300 293 1,02
To facilitate access when inspecting and/or cleaning a 200 500 548 1,76
system by simply sliding the coupling. The coupling
12 acts as an access cap.
250 150 177 0,91
250 300 297 1,35
No Click function has closed turned-over ends (at both
250 500 527 2,17
13 ends).
315 150 177 1,18
315 300 297 1,72
315 500 527 2,76
14

15

16 Ordering example
SNPU 160 150
Product
17 Dimension d1
Nominal length L

18

38 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Slide-in female coupling SMFU


Dimensions
1

d1
d
3

l li 4

Description d1 L l li m 6
Areas of use: nom nom mm mm kg
To avoid the necessity of an exact length cutting of a 80 150 40 127 0,16
duct when it is difficult to take a proper measure. E.g. 80 300 40 288 0,30 7
the connection of a duct to a stub on an air supply ter-
minal. In this case the slide-in coupling shall be 80 500 40 552 0,65
secured with screws or pop rivets. 100 150 40 127 0,20
To make it possible to use a duct that is cut to a too 100 300 40 288 0,38 8
short length instead of having to cut a new duct to 100 500 40 552 0,81
the correct length. In this case the slide-in coupling
125 150 40 127 0,25
shall be secured with screws or pop rivets.
125 300 40 288 0,47
9
To eliminate or minimize the number of ordinary duct
cuttings at building site together with pre-cut ducts 125 500 40 552 1,01
of shorter lengths. In this case the slide-in coupling 160 150 40 127 0,31
shall be secured with screws or pop rivets.
10
160 300 40 288 0,60
To assist when inserting or adding an other product
into an existing system. E.g. the cutting-in of an extra 160 500 40 552 1,29
silencer. In this case the slide-in coupling shall be 200 150 40 127 0,49 11
secured with screws or pop rivets. 200 300 40 297 0,96
To assist when removing an other product when 200 500 40 552 1,67
cleaning a system. E.g. the removal of a damper with a
obstructionable blade.
250 150 60 192 0,90 12
To facilitate access when inspecting and/or cleaning a 250 300 60 302 1,28
system by simply sliding the coupling. The coupling 250 500 60 537 2,10
acts as an access cap. 315 * 150 60 182 1,11 13
To extend the distance between a T-piece and an
315 * 300 60 297 1,62
access cap, e.g. EPFH or KCU, to get the cap outside
315 * 500 60 537 2,64
any insulation. In this case the slide-in coupling shall 14
be secured with screws or pop rivets only at its female
end. * With stiffening bead.

No Click function has a closed turned-over end and hasnt 15


any notches.

16

Ordering example
SMFU 200 150
17
Product
Dimension d1
Nominal length L 18

We reserve the right to make changes without prior notice 39


lindab | resid ential ven tilati on

End cap EPF


Dimensions
1

2
l

d
4

6 Description d l m
End cap, which fits outside a Safe fitting. nom mm kg
No Click function no notches. 63 40 0,04
7 80 * 48 0,07
100 * 48 0,11
125 * 48 0,14
8 160 * 48 0,17
200 * 46 0,21
250 * 68 0,50
9 315 * 60 0,67

* With turned-over edge


10 ** Hand made

11

12

13

14

15

16 Ordering example
EPF 250
Product
17 Dimension d

18

40 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Take-off ILRU
Dimensions
1

1030
l

d1
4

Description d1 l m 6
Take-off with radius. nom mm kg
63 10 0,07
80 12 0,10 7
100 15 0,11
125 20 0,14
160 25 0,19 8
200 25 0,26
250 25 0,57
315 25 0,72
9

10

11

12

13

14

15

Ordering example 16
ILRU 250
Product
Dimension d1 17

18

We reserve the right to make changes without prior notice 41


lindab | resid ential ven tilati on

Take-off ILU
Dimensions
1

1020
2

d1
4

6 Description d1 m
Take-off without radius. nom kg
63 0,07
7 80 0,07
100 0,08
125 0,11
8 160 0,16
200 0,17
250 0,33
9 315 0,42

10

11

12

13

14

15

16 Ordering example
ILU 250
Product
17 Dimension d1

18

42 We reserve the right to make changes without prior notice


lindab | residential ventil ation

Take-off ILF
Dimensions
1

10-20
l 2

d
4

Description d l m 6
Take-off without radius. With female end fits outside a nom mm kg
Safe fitting. 63 45 0,06
Hasnt any Click function hasnt any notches. 80 45 0,08 7
100 45 0,06
125 45 0,08
160 45 0,16 8
200 45 0,21
250 65 0,31
315 65 0,46
9

10

11

12

13

14

15

Ordering example 16
ILF 200
Product
Dimension d 17

18

We reserve the right to make changes without prior notice 43


lindab | resid ential ven tilati on

Casting-in programme Wall TVILU


stub
Dimensions
1

d1
255
3

4
255
5

6 Description d1 m
With Safe connection. nom kg
100 0,29
7 125 0,31
160 0,32

10

11

12

13

14

15

16 Ordering example
TVILU 100
Product
17 Dimension d1

18

44 We reserve the right to make changes without prior notice

Vous aimerez peut-être aussi