Remote Monitoring for Oil and Gas Applications

A critical requirement for todays petroleum extraction and delivery systems is reliable, comprehensive
monitoring of remote equipment and the processes it handles. Data collection and analysis at the process-

Moxas ioPAC RTU Controller Remote Monitoring Solutions


and system layers is used to provide actionable advance warnings and immediate alarms to maintenance
engineers both in the field and in the control room. For this reason, data integrity and speed of delivery are
critical factors that cannot be neglected. Moxas ioPAC 5500 RTU controller allows engineers managing oil
and gas fields to connect a large array of sensors back to a central control center, and to configure it with
local, event-driven alarms and responses.
ioPAC 5500 Series Dual processor RISC platform: 1 ARM9 CPU, 1 I/O processor
ioPAC 5500 Series RTU Controllers
Supports C/C++ or IEC 61131-3 programming

ioPAC 5542-HSPA
Flow
Meter
System Requirements
Open programming platform
RTU Controllers Dual Ethernet interfaces, for redundancy or port trunking
HSPA 5.76 Mbps upload and 14.4 Mbps download speeds (ioPAC 5542-HSPA only) for Remote Monitoring Applications
Cellular communication Model Name Description
Solar powered, for a low power profile ioPAC 5542-HSPA-C/IEC-T Cellular, C/C++ or IEC 61131-3 programming, 8 AIs, 8 DIs, 8 DIOs
External storage for data buffering ioPAC 5542-C/IEC-T Ethernet, C/C++ or IEC 61131-3 programming, 8 AIs, 8 DIs, 8 DIOs
Wide temperature tolerance * Note: IEC 61131-3 programming version available in 2014/Q2

Flow 4-20mA
Meter
Valve Why Moxa?
DI
Relay
Flow
Supports C/C++ and IEC 61131-3
programming
ioPAC 8500 Series Dual processor RISC platform: 1 ARM9 CPU, 1 I/O processor
Analog input prerecord window and millisecond timestamp granularity
Meter 4-20mA
Embedded HSPA RTU Controllers Supports C/C++ or IEC 61131-3 programming
Digital I/O and analog inputs supported Modular I/O for versatility, flexibility, and scalability
microSD storage
Model Name Description
-30 to 75C temperature tolerance ioPAC 8500-2/5/9-RJ45/M12-C-T 2/5/9 slots, RJ45/M12 Ethernet ports, C/C++ programming
ioPAC 8500-2/5/9-RJ45/M12-IEC-T 2/5/9 slots, RJ45/M12 Ethernet ports, IEC 61131-3 programming
85M-1602-T 16 DIs, Sink/Source
85M-2600-T 16 DOs, Sink
85M-3800-T 8 AIs, 4-20 mA

Remote Monitoring for Railway Applications 85M-3810-T


85M-3801-T
8 AIs, 0-10 V
8 AIs, 4-20 mA, 40 kHz
85M-3811-T 8 AIs, 0-10 V, 40 kHz
85M-6600-T 6 RTDs
Moxa RTU controllers for railways are EN 50121-4 compliant. Optimized for collecting real-time field data for
85M-6810-T 8 TCs
railway asset monitoring, these controllers offer system integrators an accurate, easily integrated and non- 85M-5401-T 4 serial ports, DB44-to-DB9 cable included
intrusive open platform. Moxa RTU controllers support C/C++ and IEC 61131-3 programming. When used
* Note: IEC 61131-3 programming version available in 2014/Q2
with Moxa IP surveillance cameras, administrators can quickly and easily build powerful, event-triggered
subsystems for visual anti-vandalism monitoring. Moxas software and API improvements further provide
strong enhancements to system troubleshooting and maintenance.

Moxa Sales and Marketing The Americas Europe Asia Pacific China
Wayside Condition Monitoring System Features Headquarters Moxa Americas Moxa Germany Moxa Taiwan Moxa Shanghai
Turnout condition monitoring
Flexible programming platform Toll Free: 1-888-669-2872 Toll Free: 1-888-MOXA-USA Tel: +49-89-37003-99-0 Tel: +886-2-8919-1230 Tel: +86-21-5258-9955
Track circuit monitoring
Compact design to conserve cabinet Tel: +1-714-528-6777 Tel: +1-714-528-6777 Fax:+49-89-37003-99-99 Fax: +886-2-8919-1231 Fax: +86-21-5258-5505
Level crossing monitoring space Fax: +1-714-528-6778 Fax:+1-714-528-6778 europe@moxa.com asia@moxa.com china@moxa.com
Cold rail detection Compliant with railway standards usa@moxa.com usa@moxa.com
Dragging equipment detection
Moxa Design and Engineering Moxa Brazil Moxa France Moxa India Moxa Beijing
Why Moxa? Headquarters Tel: +55-11-2495-3555 Tel: +33-1-30-85-41-80 Tel: +91-80-4172-9088 Tel: +86-10-6782-3959/61
Tel: +886-2-8919-1230 Tel: +55-11-2495-3555 Fax: + 33-1-30-47-35-91 Fax: +91-80-4132-1045 Fax: +86-10-6872-3958
Supports C/C++ and IEC 61131-3 china@moxa.com
programming Fax:+886-2-8919-1231 brazil@moxa.com france@moxa.com india@moxa.com
All-in-one design: configurable digital info@moxa.com
I/O, analog input, serial and Ethernet
interfaces
Moxa UK Moxa Russia Moxa Shenzhen Moxas RTU Controller Solutions
Strong ESD and surge protection for Tel: +01844-355601 Tel: +7(495)287-0929 Tel: +86-755-8368-4084/94
Fax: +86-755-8368-4148
Moxas ioPAC 5500 and 8500 series RTU controllers are built
enhanced system reliability Fax: +01844-353553 russia@moxa.com
china@moxa.com to make remote monitoring much easier
uk@moxa.com

ioPAC 5542-HSPA ioPAC 5542 ioPAC 8500


Cellular RTU Ethernet RTU Modular RTU

2014 Moxa Inc. All rights reserved.


Controller Controller Controller
www.moxa.com
The MOXA logo is a registered trademark of Moxa Inc. All other logos appearing in this catalog are the intellectual property of the respective company,
product, or organization associated with the logo.
RTUs Built for Remote Field Monitoring
With high sampling rates, a prerecorded event buffer, millisecond scale timestamps, and either C/
Easy system configuration and maintenance
C++ or IEC 61131-3 programming platforms, Moxa ioPAC 5500 RTUs deliver both extreme accuracy
and powerful programming tools, giving engineers a strong, efficient platform to support monitoring
and analytical processes like identifying anomalous intrusions, or device failures. Designed to work RTUxpress makes device configuration easy
reliably in harsh industrial environments, ioPAC 5500 standalone controllers feature railway-grade
RTUxpress is a user-friendly and intuitive offline configuration tool
ESD and surge protection, wide tolerance for temperatures from -40 to 75C (-30 to 75C for HSPA
for Moxas ioPAC 5500 RTU controllers. RTUxpress is provided
models), and are UL/cUL Class 1 Division 2 certified. For network redundancy and communications
free of charge, and may be upgraded as required, as new versions
security, ioPAC 5500 devices come with two 10/100 Mbps Ethernet ports that may be trunked into
become available. RTUxpress has a user-friendly
a single uplink, as well as two software-selectable 3-in-1 serial ports. With its targeted hardware
interface for device setup,tag management,
and software optimizations, the ioPAC 5500 series provides a comprehensive solution for data
and service configuration.
acquisition and control applications in harsh environments.

Easy data integration with Sustainable system reliability, Easy configuration and installation for
Accurate, rapid, reliable data Moxas OPC and DBMS software even in harsh environments distributed monitoring applications
High sampling rate on analog inputs for precise Push-based Active OPC Server and UL/cUL Class 1 Division 2 compliant Easy configuration and installation for
event analysis DA-Center data historian distributed monitoring applications
ioPAC 5500 RTU controllers are compliant with UL/cUL Class 1 Division
Moxas ioPAC 5500 RTUs use dual, industrial-grade ARM9 CPUs Moxas ioPAC 5500 RTU controllers come with Moxas patented 2 standards for harsh environments, as well as the EN 50121-4 standard Moxas ioPAC 5500 Series RTU controllers are compact,
powerful enough to support 250 Hz sampling rates for analog Active OPC Server and DA-Center software. Active OPC server for electromagnetic compatibility. With these certifications, extreme standalone devices with two 10/100 Mbps Ethernet ports
inputs. With such fine sampling precision, engineers can easily adds a non-polling architecture to the standard OPC protocol, temperature tolerance (from -40 to 75C on standard models, -30 to 75C (featuring independent MACs, for convenient port trunking)
acquire the data they need to discover the appropriate corrective giving users the advantage of active, push-based communication for HSPA models), and a sturdy metal case that not only extends product and two 3-in-1 serial ports, making this RTU controller ideal for
adjustments. that starts at edge controllers and travels back to the SCADA lifetime but also aids in heat dissipation and cooling, the ioPAC 5500 RTU use in cabinets with limited space. ioPAC RTU controllers also
system. DA-Center provides a standard OPC interface that controller is a rugged, durable RTU alternative suitable for a wide variety come with Moxas DA-Center DBMS softwarewhich optimizes
250 Hz/ch 10 Hz/ch integrates with Active OPC Server for real-time data collection. of industrial applications. the collection and storage of real-time operational dataand
25 25

20 20 The DA-Center interface acts as bridge between field data and now also RTUxpress, an intuitive offline configuration utility for
15 15
IT databases or spreadsheets, and provides a trend charting device setup, tag management, and service configuration.
10 VS 10
tool for better historical analysis. The combination of Active OPC
5 5
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
Server and DA-Center gives rapid data delivery while ensuring Ready-to-Run Service Packages
full data integrity.
Prerecorded analog input window IO Tag Services
ensures data integrity Easy data acquisition Events

Alarms
The ioPAC 5500 RTUs prerecord feature is equipped with an
Database DSS
Sustainable Logging Communication
analog input data buffer, so that whenever a response is triggered (Decision Support System) system reliability Easily link I/O and services
the ioPAC device may return a full record of data leading up to and with TagEasy
immediately following the event. In comparison, systems that only SCADA/HMI Email Modbus
log data after an event has occurred lose valuable forensic lead-in DA-Center Moxas innovative TagEasy implements TCP OPC
SNMP FTP
data, while those operating on high-latency networks will often tag-centric programming through
even lose critical, concurrent data immediately following the event RTUxpress, which allows engineers SMS
High ESD & System Active
itself. Active OPC to conveniently and quickly configure
surge protection OPC DNP 3.0 Modbus
Server a tag that links resources (DI, DO, AI, TCP
etc.) together with ready-to-run services
Millisecond-scale timestamps for data precision
(alarms, logging, active tags, etc.).
The dedicated I/O CPU on Moxas ioPAC 5500 is capable of For example, with TagEasy users can Easily configure ready-to-run services
logging the time of each I/O event down to the millisecond, giving access a drop-down menu to set the Moxas ioPAC 5500 RTU controllers come with pre-scripted
engineers a powerful analytical tool. With this degree of accuracy, Easy to configure
when an emergency triggers 10 separate I/O events within a
Precise data device to read a pre-defined DI tag that services for convenient configuration and programming.
returns the channel status, or change Programmers may utilize these pre-coded objects to
10-millisecond time interval engineers will still be able to clearly acquisition the value of a pre-defined internal efficiently configure our RTU controllers with the most
identify the sequence in which events occurred, even if the events variable to trigger a logging service. common alarms, data logging, messaging, and control
were recorded across different channels. From the point of view of the engineer features, significantly reducing the time and effort needed
responsible for programming, the focus for system deployment. Moxas RTUxpress utility allows
High-speed has changed from incorporating lots of programmers to rapidly configure the services they need
sampling rate * Compact
APIs to instead configuring simple tags. and then upload the configuration file to any ioPAC 5500 on
* User friendly configuration
This change of focus greatly reduces the network, reducing the configuration work of massively
the programming effort required. distributed deployments to a few simple clicks of the mouse.

Millisecond
timestamp granularity