Vous êtes sur la page 1sur 1

Reference building:

No. Building component A [m2] R`m [m2*K/W] [-] A*/R`m [W/K]


1 Opaque surfaces of the external walls 1276 1.800 0.996 706.053
2 Glazing surfaces of the external walls 421.84 0.770 0.993 544.005
3 Terrace roof 271.39 2.900 0.847 79.265
4 Slab on the ground 1093 4.500 0.847 205.727
5 Floor in contact with exterior 71.24 4.500 1.045 16.544
- Total 3062.2 - - 1551.594

Real building:
No. Building component A [m2] R`m [m2*K/W] [-] A*/R`m [W/K]
1 Opaque surfaces of the external walls 1276 2.436 1.035 542.143
2 Glazing surfaces of the external walls 421.84 0.854 0.993 490.500
3 Terrace roof 271.39 4.321 0.891 55.961
4 Slab on the ground 1093 5.033 0.891 193.496
5 Floor in contact with exterior 71.24 4.500 1.045 16.544
- Total 3062.2 - - 1298.643

Energy-optimised building:
No. Building component A [m2] R`m [m2*K/W] [-] A*/R`m [W/K]
1 Opaque surfaces of the external walls 1276 4.384 1.035 301.245
2 Glazing surfaces of the external walls 421.84 0.850 0.993 492.808
3 Terrace roof 271.39 5.090 0.891 47.507
4 Slab on the ground 1093 5.737 0.891 169.751
5 Floor in contact with exterior 71.24 4.500 1.045 16.544
- Total 3062.2 - - 1027.855