Technical document
9. Khlzellentren ............................................................................................................................................ 9
9.1 Beschreibung................................................................................................................ 9
9.2 Tranordnung............................................................................................................... 9
9.3 lm Trstock auen eingebaut....................................................................................... 9
9.4 Am Trrahmen innen angebaut................................................................................... 9
9.5 Tr-Abmessungen........................................................................................................ 9
15.6 Khlzellentren......................................................................................................... 4
15.7 Kombizellen............................................................................................................... 4
15.8 Anlieferung und Montage.......................................................................................... 4
15.9 Regalsysteme und Khlaggregate siehe Kltemappe.............................................. 4
22
Table of contents
12. Compartments
4. Coldroom surfaces
12.1 Compartment coldrooms/partition walls and doors
4.1 Coating combinations
9. Coldroom doors
9.1 Description
9.2 Door position
9.3 Installed externally on door frame
9.4 Installed internally on door frame
9.5 Door dimensions
1.1 Dimensions
1)
Not valid for Special floorpanels
2. Special features
- Sandwich construction of frost heave preventing - Tecto coldroom Special 100 with cove flooring.
coldroom panels, stable, self-supporting and - lf desired, without flooring, with plastic U-channel
dimensionally precise. for the coldroom panels (only used at above-zero
- Equipped as standard with the antimicrobial temperatures). The U-channel acts to seal coldroom
SmartProtec agent. to floor with soft edges.
- No wood used in wall, ceiling or door panels. - Coldrooms with opening door, interior light,
- Vertical, Tecto overlapping coldroom wall panels. thermometer and pressure relief valve.
- Tecto coldroom Special 100, Tecto-overlapping of Exterior fittings are integrated.
wallpanels, and interior coves to floor. - Supplied as dual compartments, with partition-walls for
- Stainless steel coldroom floors, finished jointfree operation at different temperatures.
even and firmly underlapped, with multi-directional - Supplied with Viessmann stainless steel or with aluminium
non-slip. upright shelving.
- Supplied with Viessmann refrigeration units.
- Viessmann coldroom panels are produced using Exterior plating Interior plating
Polyurethane foam with cyclopentane and are
dimensionally precise and homogeneous. They have low Standard coldrooms STA STA
heat transmission values, high pressure resistance and
great stability. STA
Special versions
- The connecting panels using groove and tongue system EST
and corrosion resistant eccentric cam locks allow fast
assembly and disassembly.
- Maximum coldroom exterior height in special versions
(coldroom with flooring):
80 100
6160 mm 6200 mm
- If the coldroom is assembled for use outside of a
building, it must be ensured that the coldroom is
protected from the weather (snow, rain, wind, etc.) by a
roof, for example. These preparations must be
completed prior to assembly.
- The ceiling panels are not designed for additional forces
(i. e. snow or wind). Prior to applying force to the roof,
e. g. during installation of a ceiling refrigeration unit or
installation of meat hanging equipment, pipes, etc.,
additional supports must be installed to ensure
sufficient strength in the structure.
4. Coldroom surfaces
height of assembly must be added. Prior to assembly
the room should be carefully measured.
Attention must be paid to installing the floor panels
only on a perfectly horizontal and smooth floor (VOB Tecto coldroom and deep-freezer Standard 80,
regulations). lf the floor is uneven or angled, the diffe- Standard 100 and Special 100 coldroom assembly-
rence must be compensated for. installation on floor plates.
8. Floor panels
T0 = Standard flooring
WB = Vat flooring
Coldroom without floor panels
Page No. 00044249-05 GB 8.4 - 8.7 Right reserved to make technical changes!
9. Coldrooms Doors 9.4 Installed internally on door frame:
- The pressure compensation valve is designed for LW x LH 2) 800 x 1800 800 x 2000 800 x 1800 800 x 2000
a refrigeration unit up to a maximum of 5 kW. 1000 x 1800 1000 x 2000 1000 x 1800 1000 x 2000
lf the refrigeration is designed for higher values, Door frame with
*
a larger valve or several valves must be installed. heating
*Normally not in stock (Dimensions in mm)
1)
The regulation at the place of work in its respective valid version
must be observed.
2)
The height above the floor is 15 mm greater for
coldrooms without floors.
Interior
Distance Width of door
width of
A assembly F
door LW
(mm) (mm)
(mm)
Coldroom Tecto coldroom and deep-freezer Coldroom Tecto coldroom and deep-freezer
(mm) type (mm) type
Exterior Standard Standard Special Exterior Standard Standard Special
dimensions WL80 WL100 100 dimensions WL80 WL100 100
2110 2150 Height 1) 2110 2150
Height 1)
2410 2450 2410 2450
15.1 Features:
Door opens (DIN) to right or left . 15.9 Shelving systems - see refrigeration brochures
Door panel polyurethane foamed with cyclopentane. 15.10 Refrigeration units - see refrigeration brochures
Page No. 00044220-09 GB 15.5 - 15.10 Right reserved to make technical changes!
16. Tendering text - specifications
Tecto coldroom and deep-freezer Standard WL80 and Standard WL100
Tecto coldroom and deep-freezer Special 100
Swinging doors
1. Single leaf Additional Price:
Interior width ________ x ________ mm, Typ _____________
Door hinges DIN left DIN right
2. Double leaf Additional Price:
Interior width ________ x ________ mm, Typ _____________
kuehlsysteme@viessmann.de
www.viessmann.de/kuehlsysteme