Vous êtes sur la page 1sur 2

AWH SERIES - COMMERCIAL/ARCHITECTURAL FAN FORCED WALL HEATERS

SUBMITTAL SHEET
AWH SERIES
FAN-FORCED
WALL HEATERS

470 Beauty Spot Rd. E, Bennettsville, SC 29512 CAPACITIES


1500, 2000, 3000,
4000 or 4800 Watts
120, 208, 240, 277, 347 or 600V
1
3000, 4000 or 4800 Watts
FILE #E21609 208 or 240, 347, 600V, 3

Thermostat Range: 40 - 90 Degrees F


Air Movement: 100 CFM

JOB NAME: _________________________________________________________________


LOCATION: _________________________________________________________________
ARCHITECT: ________________________________________________________________
ENGINEER: _________________________________________________________________
CONTRACTOR: ______________________________________________________________
SUBMITTED BY: _____________________________________________________________
DATE: ______________________________________________________________________

CATALOG PHASE
ITEM QTY. NUMBER TAG LENGTH WATTS VOLTS AMPS BUILT-IN CONTROLS

ITEM QTY. CAT. NO. TAG DESCRIPTION


ACCESSORIES
AND
CONTROLS

SUBMITTED BY: DATE APPROVED BY: DATE

ZSS-QAWH4 (03-06) Printed in U.S.A.


AWH SERIES
ARCHITECTS AND ENGINEERS SPECIFICATIONS*

The heating equipment shall include an electric automatic


fan forced air heater suitable for large area heating, as
manufactured by QMark, A Marley Engineered Products
Brand, Bennettsville, SC. The heater shall be designed
470 Beauty Spot Rd. E, Bennettsville SC 29512
for wall mounting, recess or surface. Heaters shall be UL
SELECTION CHART listed.
CATALOG NO. VOLTS PH. AMPS WATTS BTU/HR WIRE SIZE
HEATER ASSEMBLY: The heater assembly which fits
AWH3150 120 1 12.5 1500 5120 12 AWG into the back box shall consist of a fan panel upon which
AWH3180 120 1 15 1800 6142 12 AWG is mounted all of the operational parts of the heater.
AWH4408* 208 1 19.2 4000 13650 10 AWG
9.6 2000 6825 HEATING ELEMENT: The heating element shall be of
AWH4404* 240 1 16.7 4000 13650 10 AWG the non-glowing design consisting of an 80/20 nickel-
8.3 2000 6825 & 12 AWG chromium resistance wire enclosed in a steel sheath to
208 1 14.4 3000 10235 which plate fins are copper brazed. It shall be warranted
7.2 1500 5120 for 5 years.
AWH4407* 277 1 14.4 4000 13650 12 AWG
7.22 2000 6825 FAN AND FAN MOTOR: The fan shall be five-bladed
240 1 12.5 3000 10235 aluminum. The fan motor shall be totally enclosed.
6.3 1500 5120
AWH4307* 277 1 10.8 3000 10235 12 AWG FAN DELAY SWITCH: Fan control shall be of bi-
5.4 1500 5120 metallic, snap-action type and shall activate fan after
AWH4303 347 1 8.6 3000 10235 14 AWG heating element reaches operating temperature. The
AWH4508 208 1 23.1 4800 16380 10 AWG fan shall continue to operate after the thermostat is
AWH4504 240 1 20 4800 16380 10 AWG satisfied and until the heating element is cool.
208 1 17.3 3600 12285
AWH4507 277 1 17.3 4800 16380 10 AWG THERMOSTAT: The tamper-proof thermostat shall be of
240 1 15 3600 12285 the bi-metallic, snap-action type with enclosed contacts.
AWH4503 347 1 13.8 4800 16380 12 AWG It shall be completely concealed behind the front cover to
AWH4506 600 3 4.6 4800 16380 14 AWG become tamper proof.
AWH44083 208 3 11.1 4000 13650 14 AWG
AWH45083 208 3 13.3 4800 16380 12 AWG THERMAL CUTOUT: A thermal cutout shall be built into
AWH44043 240 3 9.6 4000 13650 14 AWG the system to shut off the heater in the event of over-
AWH45043 240 3 11.6 4800 16380 14 AWG heating.
AWH4306 600 3 3.0 3000 10235 14 AWG
*Heaters shipped at higher wattage. Units can be converted to half-wattage in field. DISCONNECT SWITCH: A double-pole single throw
disconnect switch shall be mounted on the back box for
ACCESSORIES positive disconnect of power supply. It will be completely
CATALOG NO. DESCRIPTION concealed behind the front grid panel.
Pneumatic/Electric switch. Factory set at 10 psig
to make on pressure drop. May be field wired
AWH-PE to break on pressure drop. Pressure set point
PNEUMATIC/ELECTRIC SWITCH: An optional
adjustable to 30 psig. (Field installed.) pneumatic/electric switch shall be available for use with
AWH-R2 (24 volt) Time delay relay 40-60 seconds to close when energy management systems employing pneumatic
AWH-R12 (120 volt) energized. Use 120V or 24V power supply from pressure devices for controlling comfort levels and set-
remote source. (Field installed.)
1 deep surface mounting frame for semi-
back operations.
AWH-S-1 recessed installation.
AWH-S-2 Same as above except 2 deep. LOW VOLTAGE RELAYS: Normally open 24-volt and
AWH-SM Surface mounting frame for surface installations. 120-volt low voltage holding coil relays shall be available
Painted to match heater decor, 313/16 deep. as optional equipment to control 208, 240, or 277 volt
LFK-SFC 14 Gauge security front cover.
heaters in conjunction with central energy control sys-
tems. The built-in thermostat can then be used as one of
DIMENSIONS the thermostats in an automatic night set back operation.

BACK BOX: The back box shall be designed for duty as


a recessed rough-in box in either masonry or frame
installations and is also used with the surface mounting
frame in surface mounting installations. The back box
A
shall be 20-gauge galvanized steel and shall contain
SM
knockouts through which power leads are brought.
S1

S2
FRONT PANEL: The front panel shall be of the bar grille
type and shall be constructed of 16-gauge cold-rolled
steel, welded into a uniform grille and finished in baked
enamel to direct the warmed air toward the floor. The
front grille shall be surrounded by a decorative satin-
finish aluminum "picture" frame.
"A" "B" "C" "D"
MODEL RECESSED THICKNESS FRONT TOTAL THREE PIECE DESIGN: The heater shall be made of a
DIM. OF FRAME COVER EXT. INTO back box, a heater assembly, and a front panel.
DIM. ROOM
SM 3-13/16'' 1-1/2'' 5-5/16'' *QMark reserves the right to change specifications
without prior notice.
S2 1-13/16'' 2'' 1-1/2'' 3-1/2''
S1 2-13/16'' 1'' 1-1/2'' 2-1/2''
RECESSED 3-3/4'' 1-1/2'' 1-12''

Vous aimerez peut-être aussi