Vous êtes sur la page 1sur 75

All DC Inverter Multi VRF

In 2012, Gree highly promoted GMV5 All DC Inverter Multi VRF

New breakthrough in comfort ability, intelligent control and design.


Eight More powerproduct
More powerful product series
series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More power product


More reliableseries
performance

More convenient project installation

Safer operation

More intelligent management

Smarter network control


All DC Inverter Multi VRF

8 1 0 12 14 16 HPcombination 18
~
64 HP
9 2 1 23 25 27
0 3 2 34 36 38
64HP big capacity

1. Module 8~16HP 2 . Module 18~32HP

3 . Module 34~48HP 4 . Module 50~64HP


64HP Wide Capacity Range

64HP 8~16HP
1 Module 2 Modules 18~32HP

Max Capacity

3 Module 34~48HP 64HP


4 modules 50~64HP

8HP
Ultra-low noise duct Ultra-low noise cassette High ESP duct type Low static pressure Duct

One-way cassette Dual heat-source duct Floor ceiling Console

Wall mounted Fresh air IDU 4-way cassette

11 kinds of indoor units for various places.


Eight More powerful product series
prominent advantagesMoreMore
excellent
excellentenergy-saving effect
energy-saving effect

More comfortable air quality

More reliable performance


More excellent energy-saving effect
More convenient project installation

Safer operation

More intelligent management

Smarter network control


System energy efficiency
Exceed national grade 1 energy efficiency standard; energy-saving up to 59%
GMV5 National grade 1

5.7 5.72
5.72
5.55 5.5 5.2

3.6 3.6 3.55 3.55 3.55

8HP 10HP 12HP 14HP 16HP


High-efficiency DC inverter compressor

64HP
DC inverter compressor control technology

traditional torque control


GMV5 torque control Max. output
Output torque

Moment is not enough

GMV5 torque control


Nt.m
Traditional torque control

Current of compressorA
DC inverter fan control technology

Efficiency is improved greatly


Before Now
T T

I I
Adopt DC inverter motor to realize 5Hz~65Hz stepless speed adjustment.
Compared with common DC inverter motor, operation current and motor input
power are much lower, while efficiency is improved greatly.
DC Inverter Fan Control Technology
traditional notch adjustment
65Hz

Capacity output of inverter compressor

GMV5 stepless speed adjustment


7
6
5
4

VS
3
2
1
traditional notch adjustment GMV5 stepless speed adjustment

Inverter fans frequency Low efficiency


High efficiency
Big noise
GMV5 DC Low noise

inverter
Bad reliability
Good reliability

fan motor
Indoor unit adopts DC brushless motor
Efficiency is increased above 30% by using DC brushless motor
Stable operation; low noise
Lowest speed can reach 100r/min.

Dynamic characteristic

DC brushless motor

Asynchronous motor
Intelligent defrosting technology

defrosting defrosting defrosting


Traditional defrosting mode
capacity
Heating

Heating timer mode

Less comfortable! Low


Time
8min 45min 8min 45min 8min energy efficiency!
defrosting

Intelligent defrosting mode


capacity
Heating

heating
More comfortable!
Specification is promoted!
When theres frost detected by system, When frost is over, the system
intelligent defrosting will be Will stop defrosting automatically
started up automatically
Fan linkage control technology

Normal multi VRF GMV5 multi VRF

Unbalanced fan operation method; low Air volume is much even; high
energy efficiency energy efficiency
Energy-saving operation control

No need to connect remote control monitor system. During electricity limiting period,
the unit provided two kinds of energy-saving mode.
Operating cost

Save up to 15%

Save up to 20%

operating mode
ordinary mode energy-saving mode1 energy-saving mode2
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable
More comfortable air quality
air quality

More reliable performance

More convenient project installation


More comfortable air quality
Safer operation

More intelligent management

Smarter network control


Comfortable temperature

The compressor Adjust the


speed according IDU load
temp
Working principle of
Working
commonprinciple of
air conditioner Hot
Inverter air conditioner Set
temp

Cold
start Cooling operation Operating time

quick start Small temp


fluctuations
After reaching to set temperature, compressor will adjust the output
according to indoor load to let indoor temperature stay at relative stable
status and let you feel more comfortable.
Adjust indoor temperature automatically

35 26 26 26

When using traditional air conditioner for cooling, temperature at difference


places in the room is the same, which let you feel uncomfortable the moment you
enter the room.
Adjust indoor temperature automatically

35 28 27 26

Gree inverter air conditioner can adjust indoor temperature automatically


according to ambient temperature for comfortable feeling.
Low noise control technology
Quiet function for night; 9 modes for selection
Dayoutdoor Nightoperate at
temperature is high low load

capacity %

load %

operating sound dB(A)

45dBA

Operate at rated load Low load operation; low noise


Quiet control technology

Compulsory quiet function, as low as 45dBA

Has set compulsory quiet mode

Operation
noise dB(A)
Drying and reheating function
When air conditioner operates under drying mode in wet seasons, air
outlet temperature can be as low as below 10. At that time, after starting
up the electric heater, air outlet temperature can be increased to more than
10.

Drying operation

Air outlet temperature 15


9
Drying and
reheating
Fresh Function
Fresh outdoor air flows through fresh indoor units heat exchanger, and comes
into indoor rooms after being treated into proper status. Temperature will reached
to design requirement, while it wont affect air quality.

Air duct Fresh air duct pipe


indoor unit

Outdoor
fresh air
Reminding function for cleaning filter
Indoor unit is with reminding function for cleaning filter. According to
different operation environments, you can set different clean period.

days
1 days
100
2
3 days

Please clean
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More reliable
More reliable performance
performance

More convenient project installation


More reliable Safer
performance
operation

More intelligent management

Smarter network control


Refrigeration oil circulating control technologytwo-stage oil-
dispersing control technology

Total oil-dispersing
efficiency
First-class oil separator Second-class oil separator
Adopt filter expansion valve Separating the remaining 2%
Separating efficiency refrigeration oil;
reaches to 98% Separating efficiency
reaches to 95% Patent201120003910.7
Refrigeration oil circulating control technologyoil return
control technology
During oil-retuning operation, pressure is taken into
consideration, which can improve the service life of compressor.
High pressure sensor Indoor heat exchanger
compressor

EXV
Before oil-retuning
Indoor heat exchanger

Low pressure sensor

High pressure sensor Outdoor heat exchanger


compressor

Pressure control
EXV

During oil-returning
Freezing oil
Indoor heat exchanger

Pressure control

low pressure sensor


Refrigeration oil circulating control technologymodule oil-balancing
control technology
Judge operation status of module and compressor intelligently, calculate oil-
storage volume of compressor and adjust operation status of compressor to
realize the oil balance among modules.

During oil-balancing

Operation module Operation module

Oil separator
Oil separator
Refrigeration oil circulating control technologycompressor oil-
balancing control technology

Suction pipe

Control the oil level in oil


pool and distribute the Discharge pipe
redundant oil in compressor
to other compressors

Lowest oil level


oil-balancing tube

Oil-balancing Abundant oil


Refrigeration oil circulating control technology oil- storage control
technology
Due to the oil-storaging technology of compressor, the lowest oil level for operating
the compressor can be controlled by judging parameters
Outdoor heat
Controlling exchanger

Compressor
Electronic
expansion
valve

Indoor heat
exchanger
Subcooling technologyfirst class subcooling technology
Adopt high-efficiency heat exchange loop to realize first class
subcooling control for heat exchanger. Degree of subcooling can reached
11.

High temp:76
Mid temp65
Low temp50
Normal subcooling44
GMV 5 subcooling39
before now
Subcooling technologysecond class subcooling control
Realize second times subcooling for 9 by adopting overcooled loop

Outdoor unit
Indoor unit

Overcooled loop
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More reliable performance

MoreMore
convenient
convenientproject installation
project installation
More convenient project installation
Safer operation

More intelligent management

Smarter network control


Super long piping, no space-limiting

Max total piping length1000m3280ft


Max actual piping length165m 540ft
Max height difference between ODU and
IDU90m300ft
Max piping length from first branch to the
farthest IDU40m130ft
Super high static pressure, no installation position limiting

Outdoors 0Pa

Mechanical floor
80Pa

4 kinds of static pressure optional


0305080Pa
0305080Pa

For complicated construction


structure requirement

Note: The ex-factory defaulted static pressure is 0Pa


Super large capacity, no construction area limiting

Application combination of module can reach to 4 modules at the most;


selectivity of 180kW capacity is much big, which can satisfy all kinds
construction design requirement.
Super long distance communication, no distance limiting

MAX 1000m MAX 1500m


Common multi VRF
The debugging is simple and convenient

The debugging software can be connected into the outdoor unit or


the indoor unit via Gree USB data converter.

CAN bus line

USB data converter


Connected to ODU Connected to IDU
Portable computer
Intelligent debugging for saving time

functions
The wiring is simple and convenient
abnormal normal
b b
a a

b b
a a

Normal GMV
Maintenance window
Maintenance window
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More reliable performance


Safer operation
More convenient project installation

Safer operation
Safer operation

More intelligent management

Smarter network control


Distinguish emergent shutdown and insufficient power supply
Emergent shutdown
Distinguish insufficient power supply
ODU can be connected When the power is supplied by dynamotor
to fire alarm linkage signal, temporarily, the ODU will send insufficient power
which can make the unit shut supply signal to IDU. At that time, air conditioning is
down in emergency only available for VIP rooms.

Insufficient
power supply

Normal
running VIP Room

stop
Operation in emergency

The module is operating


in emergency

malfunction

Basic modules in emergency(18HP-64HP)


When one of the basic modules is in malfunction, other basic modules can still
operate in emergency, which greatly reduces the affect of malfunction.
Operation in emergency

The compressor is operating


in emergency

malfunction

Compressor in emergency(8HP-16HP)
When one of the compressors is in malfunction, other compressors and
systems in this basic module can still operate in emergency.
Operation in emergency

The fan motor is operating


in emergency
malfunction

Fan motor in emergency (Double fan motors


Some basic modules are designed with two fan motors. Gree unique control
logic and optimized system design can make sure that the other fan motor can run in
emergency when there is malfunction in one fan motor.
ODU modules installed without sequence

36HP is taken for example 12HP 8HP 16HP

Do not distinguish master unit and


slave unit
Do not distinguish big and small
Do not distinguish position
8HP 16HP 12HP

16HP 8HP
8HP 12HP
16HP 8HP 12HP12HP
8HP
ODU operates circularly

1 2 3
8:00~16:00
0:00~8:00
16:00~24:00

Operate in modules, operate evenly and prolong lifespan


Wide operation range in high temp or low temp
Solve heat island problem of concentrated installation of ODU Solve high temp problem of ODU in built-in
installation or concentrated installation

-10 55

27 -20
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More reliable performance


More intelligent management
More convenient project installation

Safer operation

More intelligent
More intelligent management
management

Smarter network control


Gate control function

The unit works when


inserting the card and stops
when pulling out the card.
When the unit stops, the unit
records the running status and
stops running; when inserting
the card, the unit will run
according to the memorized
status, in stand-by status or in
the running mode before
pulling out the card.
One indoor unit with several control points

The indoor unit can be connected to several wired controllers, which can
achieve controlling one indoor unit in different control point.

OFF
ON

Meeting room Management room


Central control of several indoor units
Several indoor units can be connected to one wired controller to realize
centralized control, maximum 16 indoor units

32
26 32
26

26
32 32
26
Controlled by remote controller and wired controller at the same time
Remote controller is convenient and wired controller is with more functions.
Gree unique control logic make it possible to control one IDU with remote
controller and wired controller at the same time.

Turn off the air con by


remote controller; no
need to get up.
Eight More powerful product series
prominent advantages More excellent energy-saving effect

More comfortable air quality

More reliable performance

Smarter network control


More convenient project installation

Safer operation

More intelligent management

Smarter network
Smarter network control
control
The first to apply CAN network control technology in the industry
Specification Normal GMV network GMV5 CAN network

Software verification Hardware verification, high reliability


High reliability
One of the indoor unit or outdoor unit is The malfunction IDU or ODU will exit
in communication malfunction, which communication automatically, which will not affect
may lead to crash of the whole network. the whole network.

Master-slave communication method, Multi master units communication way, the


which will affect the response efficiency information of all units in the network will be fed
High of slave unit; the utilization of bus line is back; the utilization of bus line is high
communicatio low
n efficiency
IDU and ODU communication efficiency can reach
Communication efficiency is low, about
20Kbps, which is improved by 100%; data
10Kbps
exchange is more quickly.

Multi master units network, easy to extend new


High Single master unit network, poor
equipments, such as light, ventilation equipment,
compatibility expansibility
etc.
Long 1000m 1500m
communicatio
n distance
Communication speed is more quickly and more accurate

GMV5
NormalCAN
GMVnetwork
network Highresponse
Low responsespeed
speed
High compatibility, leakage control of the building
Detector of
fire hazard

Support leakage control of


Light switch
other equipments

Support leakage control of


Emergency button
other air conditioning
equipments

Support control system of Connect to control of the building

the building
More visualized operation platform
The actual position of air con can be shown in the building, floor or room layout of the
system interface, which can realize visualized management of the air con.
More visualized operation platform
In the visualized interface of each area of the building, the running quantity, stopping
quantity and malfunction quantity, etc. of the air con in this area can be calculated.

Show the status of


the concerned area

Total air 213

Running qty180
Stopping qty33
Malfunction qty0

Malfunction: 0
Multi management ways of air con
Help to use and manage the air reasonably
Independent/centralized control:
The user can manage one or several equipments.

ensure cancel
Multi management ways of air con

GM office

Independent monitoring and managing for VIP customers.


Flexible linkage control
Calendar management function

2012 0 4 15
3 1
4 059
8
6
4
2
0
7
1
3
Year Month Week Day
Calendar management function

Overtime management
Dining management

Calendar office Work noon Work overtime


management of required
time and area:
Set timer on/off dining room breakfast lunch dinner
Set mode
Set temperature meeting room Work
Shielding

Avoid waste of energy


caused by forgetting
turning of the air con
Multi energy-saving modes
Electricity limit mode:
Calculate the electricity consumption;
Set the electricity consumption limit: when the electricity consumption reaches the set value,
remind or automatically control the air con to run in low electricity consumption.
Economical mode: according to the characteristics of GMV, control the output load of ODU to
keep it running in low electricity consumption.

Electricity consumption
of Room 1 has reached

80%
Analysis of electricity consumption

2 1 2 4 4 5 7 8 7 5 4 2 1 2 3 2 1 8 5
Service port
All Dc Inverter multi VRF

2 51 4 5 8 4 7 4 5 84 71 25 13 3 2 2 1 4 4 2 21 4

2 15 25 44 4 1 5 27 48 57 5
4 46 27 18 2 2 3 32 11 78 5
4
2 1 2 4 4 5 7 8 7 5 4 2 1 2 3 2 1 8 5
data

2 25 5 5 4 28 17 84 52 2 21 14 55 66 3 3 2 67 8
1 9
Not apparent cooling effect
Too much electricity

Too low set temp.


Energy visualized management function:

consumption

27
28


Energy visualized management function:

Energy consumption

Set temperature too low

make out corresponding energy-saving


policy according to the above situation
27
Service port

Cooling effect is not apparent


Make out energy-saving policy and control of that policy
Make out corresponding energy-saving policy according to
the following situation

Running time: screen out long-running air con

Turn on the unit too early

Turn off the unit too late: too much energy consumption
due to forgetting turning off the air con

Environment comfort: too much electricity consumption


due to improper setting of temp.

Electricity consumption/unit area electricity consumption: screen out


the air con which consumes too much electricity
Multi air conditioning management way

Adopt B/S system design to achieve powerful Web


control function
Management function of multi buildings
Login function of multi users
Monitoring function of Internet

U.S.A
China
2 1 2 4 4 5 7 8 7 5 4 2 1 2 3 2 1 8 5

2 15 25 44 4 1 5 27 48 57 4

2 1 2 4 4 5 7 8 7 5 4 2 1 2 3 2 1 8 5
Auto calculation of electricity

2
51
2 25 55 4 28 1
1

45 8 4 7 4 5 84
7 84 52 2 21 14 5

7
1
5 46 27 18 2 2 3 32 11 78 4

2
5
13 3 2 2 1 4 42
5 66 3 32 67 8
9
Calculate the electricity automatically according to running time, mode, opening angle of

21
electronic expansion valve, indoor ambient temperature, outdoor ambient temperature, etc.;

4
provide detailed bill, running report and analysis report.
Calculate the electricity fee of each user reasonably
User A
Electricity fee

User B

User C

User A User B User C

Calculate the electricity fee of each user reasonably to avoid disputes


Thank you!

Vous aimerez peut-être aussi